Beruflich Dokumente
Kultur Dokumente
13 Years
Plant operator:
DCS operator:
08 Years
05 Years
Cell # +974-66419289
(E-Mail: durraniffc@hotmail.com)
Job Summary.
Total more than 13 years of Domestic and Middle-East countries Oil & Gas experience in Refinery/ Gas Processing
plants performing Commissioning, Pre commissioning, Expansion & Normal Plant Operations, Startups/Shut downs
activities for,
NG Reception/Separation, Amine absorption/Regeneration unit, Dehydration, NGL Recovery/Extraction, , Sulphur
Recovery Unit, Acid Gas Enrichment,Tail Gas Treatment unit ,Chilling and Turbo-expander
operation,CDU,VDU,LPG,Nephtha stablization,Nephtha splitter,Nephtha hydro treator, Utilities plants and lots of more...
Having DCS/SCADA panel operating experience of ABB & YOKO GAWA, well conversant with different control strategies
& Laboratory Information Management System, Anti surge control system, PLC Operation, ESD, Trip Logic systems,
F&G detection and having a valid Qatar driving license
PERSONAL INFORMATION
NAME
Date Of Birth
Nationality
Marital
Status
Passport
Number
Email address
Contact
number
Age
PROFESSIONAL EXPERIENCE
Company
Designation
From
To
Plant
2011-Date
2009-2011
2008-2009
2003-2008
Qatar
Saudia
Pakistan
Pakistan
Console. Operator
Console Operator
OPERATOR
OPERATOR
Gas Treatment/SRU
Ammonia plant
Petrochemical
Ammonia Plant
Course name
Company
Location
Duration
Qatar
15 Days
Qatar
3 Days
H2S Training
Qatar
3 Days
DCS operation
Worly
Parsons
Qatar
Petroleum
Qatar
Petroleum
Yokogawa
Saudi Arabia
10 DAYS
UHDE
Saudi Arabia
20 DAYS
UHDE
Saudi Arabia
10 DAYS
SAMSUNG
Saudi Arabia
10 DAYS
SAMSUNG
Saudi Arabia
10 DAYS
NSC
Saudi Arabia
2 DAYS
1
0
1
1
Fire Fighting
Maaden
Saudi Arabia
2 DAYS
Emerson
Saudi Arabia
10 Days
Academic Qualifications
Degree
APPRENTICESHIP
Institute name
FFC TECHNICAL
Year
2003
Subjects
PLANT OPERATION
F.SC
H.SC
GOVT.COLLEGE RYK
PILOT SECONDARY SCHOOL
2000
1999
PRE-ENGINEERING
MATH PHYSICS
CHEMISTRY
General answers
Willingness to relocate
Notice period from current employer
Driving license
Salary
Yes
2months
GCC valid license/Qatar /KSA
Negotiable
Monitoring and controlling process parameters in, Gas, Condensate, Utilities, and Loading and Gas Export plants. Take
timely remedial actions in case of process alarms or plant upsets due to instrument/equipment failure, ensuring safety of
plant & personnel.
Assisting the shift supervisor in day-to-day activities by providing proper feed back and follow-up.
Providing work guidance to field Senior Operators/Operators and coordinate their activities in keeping with standard
operating procedures & standing instructions complying with companys Health, Safety & Environment policy.
Monitoring fire & gas panel and interact with fire control center during failure of any plant protection system.
In case of emergency situation, I take appropriate actions as per Qatar Petroleum emergency procedures and contingency
plans. Which includes?
To initiate work request for maintenance in case of equipment/instrument failure in co-ordination with field operators &
shift supervisor.
Follow-up work permits, take equipment/instruments out of service for maintenance and to take back in service after
maintenance intervention.
Recording all the activities that occurred during the shift in the shift Log Book.
Communication with NGL-1/2/4 Plants for any upset in their units and requiring our help.
Monitoring the quality of products and intermediates and take necessary corrective actions when the Lab analysis
indicates deviation from standard norms.
Take over shift, reading log sheets of previous shift in Main Control Room indicating temperatures, pressures, humidity etc.
Check standby equipments/generators to ascertain readiness for operation
Monitor and control the operating parameters and take decisions as required within the defined authority levels while
reporting on any anomalies to Shift Controller/ Control Room Operator.
Prepare log and handover shift to next Field Operator.
Carry out regular patrols of the plant to observe operation of equipment and machineries, generators, valves, pumps, etc.
while recoding any abnormalities, such as leaks, high temperature, abnormal noise, and reporting to Control Room Operator
for immediate action.
Initiate necessary work requests and submit to Control Room Operator for processing; operate machinery including start-up
shutdown locally and remotely as per established procedures.
Operate the equipment and valves including start-up shutdown locally and remotely while isolating equipment for
maintenance preparation, including valve isolation depressurizing and purging with nitrogen as necessary, and request
maintenance to carry out electrical isolation.
Monitor maintenance work to ensure it is carried out safely and in accordance with work permit conditions.
Carry out explosive, oxygen and toxic gas tests for hot work and vessel entry, and sign Permit to Work for approval prior to
commencement of work.
Perform daily, weekly and monthly checks including leak survey, Inergen Cylinders and oil level checks and any other checks
and ensure all checks registers are up to date.
Ensure all control room register and logs are updated including OLM, equipment handover, shift handover, PTW register or
any other log/register.
Account for and handover all control room portable equipment (radios, gas testers etc) to next shift. Monitor calibrations
dates and report.
Carry out regular patrol of perimeter fences in conjunction with the security and act as on scene commander during
emergencies, as and when required.
Take immediate corrective action in the event of an emergency while notifying Control Room Operator immediately of any
urgent situation.
Take initial action in firefighting and first aid, especially after normal working hours when no immediate assistance is
available.
Follow up on the decommissioning / commissioning of machinery and equipment after working hours and holidays.
Carry out running hours of various equipment for historical data for maintenance purposes.
Assist the Control Room Operators duties including system monitoring and controlling for operation of the gas distribution
network and highlight any non-conformances for corrective action.
Cover Control Room Operator during routine field checks and breaks and be able to analyze and accept alarms and take
corrective actions. Answer customers calls and inquires and monitor/control the plant for operation of the gas distribution
network during normal situations.
Share knowledge, experience and train the new field operators to perform their duty safely.
Perform other similar or related duties as required or assigned by management
Skills:
Steam generation package consist of three identical gas fired water steam boiler with design capacity of 50T/H.
Each of the three identical boilers consists of
BFW Pumps; water drum; steam drum; forced circulation fan;
Following control measure are equipped on the boiler
NGL EXTRACTION
Sweet gas from AGR unit pass to molecular sieves to remove the moisture up to less than 1ppm.after molecular sieves gas
passes through series of heat exchanger to knock out the raw NGL.Remaining gas feed to turbo expander where