Sie sind auf Seite 1von 7

S

CALCULATION SHEET
Job Name

Spreadsheet Development

Job Number

Subject

5S2.1

Page Number

Prepared by

yakso s

Date

0
1 of 1
31-Aug-15

Reinforcement Design for 1-way Slab


Material Properties
f'c

30 N/mm

fy

400 N/mm

density

24 kN/m3

reduction factor for flexural strength, f

0.80

Dimension
length of span, L

4000 mm

slab thickness

150 mm

concrete cover

25 mm

self weight

3.60 kN/m2

superimposed dead load

1.95 kN/m2

Load factor = 1.20

edge 2

live load

3.00 kN/m2

Load factor = 1.60

discontinue

hence, design load, qu

11.46 kN/m2

continue
edge 1

Loading

Single Flexural Reinforcement Calculation


short span
edge 1

edge 2

long span

units

mid edge and mid

M coef

0.086

0.040

0.075

qL2

183.36

183.36

183.36

Req. Mn

19.71

9.17

17.19

effective depth, d

120.00

120.00

120.00

mm

=
depth of neutral line at balance, =
max allowed comp block, amax =
depth of compression block, a =

0.85
72.000
45.900
8.342

0.85
72.000
45.900
3.805

0.85
72.000
45.900
7.240

mm
mm
mm

yes
yes
531.797 242.597
420.000 420.000
531.797 420.000

yes
461.582
420.000
461.582

is a<amax? (sect. adequacy chec=


required tensile steel area, As
=
Minimum tensile steel area, Asmi=
Thus, required tensile steel area =

kN
kNm per meter strip

mm2/m
mm2/m
mm2/m

use, rebar diameter

D10

D10

D10

D10

req. spacing for As

147.69

187.00

170.15

mm2
mm

req. spc for crack & shrinkage

300.00

300.00

300.00

450.00

mm

use spacing

125

150

125

250

mm
OK

Design Summary
reinforcement in short span

reinforcement in long span

edge 1

= D10 - 125 (TT)

edge

= D10 - 250 (T)

edge 2
midspan

= D10 - 150 (TT)


= D10 - 125 (BB)

&
midspan

= D10 - 250 (B)

design status
Valid Design

CALCULATION SHEET
Job Name
Subject
Prepared by

Reinforcement Design for 2-way Slab


Material Properties
f'c

28 N/mm

fy

400 N/mm

density

24 kN/m3

reduction factor for flexural s

Dimension
=

4500 mm

panel length, Ly

6300 mm

slab thickness

150 mm

concrete cover

20 mm

self weight

extra dead load

3.60 kN/m
2
1.00 kN/m

Load factor = 1.20

2
4.00 kN/m

Load factor = 1.60

2
11.92 kN/m

continue

panel width, Lx

Loading

imposed load
hence, design load, q

Single Flexural Reinforcement Calculation


edge 1

midspan

short span
edge 2

edge 3

long span
midspan edge 4

M coef

0.000

0.055

0.074

0.045

0.034

0.000

qLx

241.38

241.38

241.38

241.38

241.38

241.38

Req. Mn

0.00

16.66

22.22

13.68

10.26

0.00

effective depth, d

125.00

125.00

125.00

115.00

115.00

115.00

0.85

0.85

0.85

0.85

0.85

0.85

depth of neutral line at balance, c =

75.000

75.000

75.000

69.000

69.000

69.000

max allowed comp block, amax

47.813

47.813

47.813

43.988

43.988

43.988

depth of compression block, a

0.000

7.209

9.713

6.426

4.785

0.000

is a<amax? (sect. adequacy check=

yes

yes

yes

yes

yes

yes
0.000

required tensile steel area, As

0.000

428.953

577.896 382.374

284.690

Minimum tensile steel area, Asmin=

437.500

437.500

437.500 402.500

402.500 402.500

Thus, required tensile steel area

437.500

437.500

577.896 402.500

402.500 402.500

use, rebar diameter

D10

D10

D10

D10

D10

D10

req. spacing for As

179.52

179.52

135.91

195.13

195.13

195.13

req. spc for crack & shrinkage

300.00

300.00

300.00

300.00

300.00

300.00

use spacing

150

150

100

150

150

150

Design Summary
reinforcement in short span

reinforcement in long span

edge 1

= D10 - 150 (TT)

edge 3

midspan

= D10 - 150 (BB)

midspan

edge 2

= D10 - 100 (TT)

edge 4

Job Number

Page Number

1 of 1

Date

31-Aug-15

reduction factor for flexural strength, f

edge 2
continue

discontinue

edge 4

edge 3

discontinue
edge 1

0.80

units

kN
kNm per meter strip
mm
mm
mm
mm
mm2/m
mm2/m
mm2/m
mm2
mm
mm
mm
OK

D10 - 150 (T)


D10 - 150 (B)
D10 - 150 (T)
design status
Valid Design

CALCULATION SHEET
Job Name

Spreadsheet Development

Job Number

Subject

5S2.1

Page Number

Prepared by

yakso s

Date

0
1 of 1
31-Aug-15

Reinforcement Design for Cantilever Slab


Material Properties
fcu
fy
density

=
=

30 N/mm
400 N/mm

24 kN/m3

reduction factor for flexural strength, f

0.80

Dimension
length of span, L

1600 mm

slab thickness

175 mm

concrete cover

25 mm

self weight

4.20 kN/m2

extra dead load

1.95 kN/m2

Load factor = 1.20

imposed load

3.00 kN/m2

Load factor = 1.60

hence, design load, q

continue

Loading

free

12.18 kN/m

Single Flexural Reinforcement Calculation


short span
top

long span

units

bottom top & bottom

units

M coef

0.500

qL2

31.18

kN

Req. Mn

19.49

kNm per meter strip

effective depth, d

145.00

0.85

depth of neutral line at balance,=

87.000

mm

max allowed comp block, amax =

55.463

mm

depth of compression block, a =

6.745

mm

is a<amax? (sect. adequacy che=

yes

required tensile steel area, As

mm

430.001

mm2/m

Minimum tensile steel area, Asm=

507.500

mm2/m

Thus, required tensile steel area=

507.500

mm2/m

use, rebar diameter

D10

req. spacing for As

154.76

mm

req. spc for crack & shrinkage =

350.00

450.00

450.00

mm

150

300

300

mm

use spacing

D10

D10

mm2

OK
Design Summary
reinforcement in
short span top

= D10 - 150 (TT)

short span bottom


long span (top & bottom)

= D10 - 300 (BB)


= D10 - 300 (B) & (T)

design status
Valid Design

CALCULATION SHEET
Job Name

Spreadsheet Development

Job Number

Subject

check of example beam

Page Number

Prep'd by

Angga

Date

1 of 1
###

Reinforcement Design for Rectangular Beam


MATERIAL STRENGTH
Concrete compressive strength, f'c
Reinforcing steel yield strength, fy

28 MPa
400 MPa

Reinforcing steel shear strength, fv

240 MPa

REDUCTION FACTOR
Reduction factor for flexural strength, f
Reduction factor for shear strength, v

0.90
0.75

FACTORED FORCES
Factored flexural moment, Mu

26.7 kNm

Factored shear, Vu

66 kN

SECTION SIZE
Depth, h
Width, b
Concrete cover to rebar center, d'

150 mm
1000 mm
50 mm

CALCULATION - FLEXURAL REINFORCEMENT


Effective depth, d
1

100.000 mm
0.850
60.000 mm

Depth of neutral line at balance condition, cb


Maximum allowed depth of compression block, amax

38.250 mm

Minimum tensile steel area, Asmin

350.000 mm2

Calculated depth of compression block, a

13.357 mm

Is double reinforcement needed?

no

Compressive force developed in concrete alone, C


Moment resisted by concrete comp and tens stress, Muc

N/A
N/A

Moment resisted by compression steel, Mus

N/A

Stress in compression steel, f's

N/A

Compression steel area, A's


Required tensile steel area to balance compression steel, As2

N/A
N/A

Required tensile steel area to balance compression in concrete, As1

794.744 mm2

Thus,
Required compression steel area

Not Needed

Required tensile steel area

794.744 mm2

Use,
Compression rebar

3 D10

(A's = 235.62l mm2)

Tension rebar

4 D16

(As = 804.25l mm2)


OK

CALCULATION - SHEAR REINFORCEMENT


Req. Vn = Vu/v

88.000 kN

Concrete shear capacity, Vc

88.192 kN
0.5 Vc < Vn < Vc, minimum shear reinforcement is needed

Shear force to be resisted by shear reinforcement

N/A

Required shear reinforcement area to resist the shear force

N/A

Minimum shear reinforcement area


Maximum rebar spacing

1.389 mm2/mm
50.000 mm

Thus,
Required shear reinforcement area to be provided, Av

1.389 mm2/mm

Use,
Shear reinforcing steel

2 legs

D10 - 200 (Av = 0.79l mm2/mm)


FAILS, check warning message

DESIGN SUMMARY
Flexural - compression rebar

3 D10

Flexural - tension rebar

4 D16 S, check error message

Shear rebar

D10 - 200

Design Status:

CALCULATION SHEET
Job Name

Spreadsheet Development

Subject

5S2.1

Prepared by

yakso s

Reinforcement Design for 2-way Slab


Material Properties
f'c

25 N/mm

fy

400 N/mm

density

24 kN/m3

reduction factor for flexural s

Dimension
=

5000 mm

panel length, Ly

5500 mm

slab thickness

110 mm

concrete cover

20 mm

self weight

extra dead load

2.64 kN/m
2
1.70 kN/m

Load factor = 1.20

2
1.00 kN/m

Load factor = 1.60

2
6.81 kN/m

continue

panel width, Lx

Loading

imposed load
hence, design load, q

Single Flexural Reinforcement Calculation


edge 1

midspan

short span
edge 2

edge 3

long span
midspan edge 4

M coef

0.044

0.033

0.044

0.037

0.028

0.000

qLx

170.20

170.20

170.20

170.20

170.20

170.20

Req. Mn

9.34

7.01

9.34

7.80

5.85

0.00

effective depth, d

85.00

85.00

85.00

75.00

75.00

75.00

0.85

0.85

0.85

0.85

0.85

0.85

depth of neutral line at balance, c =

51.000

51.000

51.000

45.000

45.000

45.000

max allowed comp block, amax

32.513

32.513

32.513

28.688

28.688

28.688

depth of compression block, a

6.733

4.996

6.733

6.391

4.738

0.000

is a<amax? (sect. adequacy check=

yes

yes

yes

yes

yes

yes
0.000

required tensile steel area, As

357.671

265.431

357.671 339.499

251.728

Minimum tensile steel area, Asmin=

297.500

297.500

297.500 262.500

262.500 262.500

Thus, required tensile steel area

357.671

297.500

357.671 339.499

262.500 262.500

use, rebar diameter

D10

D10

D10

D10

D10

D10

req. spacing for As

219.59

264.00

219.59

231.34

299.20

299.20

req. spc for crack & shrinkage

220.00

220.00

220.00

220.00

220.00

220.00

use spacing

200

200

200

200

200

200

Design Summary
reinforcement in short span

reinforcement in long span

edge 1

= D10 - 200 (TT)

edge 3

midspan

= D10 - 200 (BB)

midspan

edge 2

= D10 - 200 (TT)

edge 4

Job Number

Page Number

1 of 1

Date

31-Aug-15

reduction factor for flexural strength, f

edge 2
continue

discontinue

edge 4

edge 3

continue
edge 1

0.80

units

kN
kNm per meter strip
mm
mm
mm
mm
mm2/m
mm2/m
mm2/m
mm2
mm
mm
mm
OK

D10 - 200 (T)


D10 - 200 (B)
D10 - 200 (T)
design status
Valid Design