Low Voltage Power Circuit Breakers 4000A Narrow

Eatons new 4000A narrow frame


power and air circuit breaker

18.96
(481.6)

16.18
(410.9)

Introduction

Features and benefits

The MagnumE DS product


line has the smallest ANSI/ULT
4000A frame available on the
market today, enabling smaller
enclosures for decreased
footprint. It is over 8 inches
less in width than the current
Magnum 4000A frame.

The new 4000A narrow frame


offers the technology and innovation of Eatons Magnum Series in
a new compact size and weight.

Applications
The new 26-inch wide Magnum
4000A narrow breaker meets
application needs for UL 1066
switchgear and switchboard
applications and IEC 60947-2
control and switchgear
applications.
The design and configuration
of the new Magnum 4000A
narrow frame enables OEMs to
use easier to handle bus sizes
for standard 4000A applications.

The new 4000A narrow frame


is over 8 inches smaller
in width than the current
Magnum 4000A narrow

DigitripE

trip unit technology


featuring Zone Selective
Interlocking and Arcflash
Reduction Maintenance
SystemE technology

Internationally approved
factory-installed and fieldinstallable accessories
with four auxiliary switches
available

Communications with translators to common protocols,


such as INCOME, ModbusT
and PROFIBUST

26.25
(666.8)

Eaton's most compact 4000A


narrow breaker is designed to
provide excellent safety with a
high level of performance in a
size that meets the switchgear
and switchboard needs for a
global market.

Ratings for Magnum 4000A Narrow Frame


ANSI/UL 1066

Ratings at 508 Vac

Breaker
Type

Interrupting
Rating kAIC

Short-Time Withstand
Rating kAIC

Interrupting
Rating kAIC

Ratings at 635 Vac


Short-Time Withstand
Rating kAIC

MDN640
MDN840
MDNC40

65
85
100

65
85
100

65
65
65

65
65
65

IEC 60947-2

Ratings at 440 Vac

Breaker
Type

Interrupting
Rating kAIC

Short-Time Withstand Rating Interrupting


kAIC1 Second
Rating kAIC

Short-Time Withstand
Rating kAIC1 Second

MWN640
MWN840
MWNC40

66
85
105

66
85
105

66
66
66

Ratings at 690 Vac

66
66
66

5.00
(127.0)

3.75
(95.3)

15.38
(390.6)

24.90
(632.5)

4.55
(115.6)

15.50
(393.7)

10.31
(261.9)

13.75
(349.3)

16.46
(418.1)

13.38
(339.9)

1.20
(30.5)

0.88
(22.4)

25.00
(635.0)

10.10
(256.5)

Front View

Top View

4.61
(117.1)

Side View

Magnum 4000A Narrow Frame Drawout Air Circuit Breaker

26.25
(666.8)

9.31
(236.5)
4.86
(123.4)

12.45
(316.2)

20.48
(520.2)
18.96
(481.6)

6.34
(161.0)

15.52 (394.2)

5.00
3.75 3.75
(95.3) (95.3) (127.0)

8.47
(215.1)

18.71
(475.2)
9.72
(246.9)

0.35
(8.9)

0.75
(19.1)
7.38
5.69
7.38
(187.5) (144.5) (187.5)

Top View

Front View

1.93
(49.0)

0.95 1.79
(24.1) (45.5)

11.33
(287.8)
0.75 1
(19.1)
0.75 1
(19.1)

18.05
(458.5)
0.53
(13.5)

11.59
(294.4)

16.18
(411.0)

6.93
(176.0)

Side View

1.75
(44.5)

Magnum Air Circuit Breaker 4000A Narrow Frame Cassette


1 Thickness of stab.
Note: Dimensions in inches (mm). All dimensions are for reference only. Visit www.eaton.com for 3D CAD blocks and more dimensional drawings.

Eaton Corporation
Electrical Sector
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN-CARE (877-386-2273)
Eaton.com
2011 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. PA01301020E / Z10809
February 2011

PowerChain Management is a registered


trademark of Eaton Corporation.
All other trademarks are property of their
respective owners.

Das könnte Ihnen auch gefallen