DAIKIN ALTHERMA
LOW TEMPERATURE
HEAT PUMP
Best seasonal
efficiencies,
Perfect fit
p. 4
p. 12
offered in 3
solutions
Integrated floor
standing unit,
p. 20
Integrated
solar unit,
solar support for domestic hot water with unpressurised solar system
lightweight plastic tank
bivalent option: combinable with a secondary heat source
app control possible
p. 26
p. 30
Best seasonal
providing the highest savings
on running costs
l efficiencies
1.
SWING
SCROLL
The seasonal efficiency (also called SCOP) of a heat pump is the average efficiency over a whole year, taking into account
specific climatic conditions and house specifications (heat load, required water temperatures, etc. ). This means the SCOP
value can be seen as the real operating efficiency of a heat pump system, taking into account all the required inputs and
specific application conditions.
The total heating output per year is defined by the climatic conditions and house specifications and is independent
to the type of heating system. The total electricity input per year is the critical parameter as this is what the customer
pays for.
2.
The electrical back-up heater assistance is no longer required or only very limited.
These high heating capacities, available on the whole Daikin Altherma low temperature 4kW-16kW range, are achieved
thanks to the combination of:
Optimised controls to achieve higher frequency of use at low outdoor temperatures
Liquid injection to avoid too high discharge temperatures when high water temperatures are required
at low outdoor temperatures
Perfectly dimensioned plate heat exchangers to maximise the heat exchange surface
Location: Munich
Design temperature: -15C
Heat load: 14kW
Heating off temperature: 16C
18
16
14
12
10
8
6
Less
back-up
heater
required
4
2
Standard heat pump system
ERLQ016CAV3
Heat load
0
-15
-10
-5
Outside temperature (C)
Daikin Altherma low temperature has a high modulating range, meaning the compressor can modulate down to low
frequencies to offer the highest efficiencies over the relevant temperature range.
Each inverter compressor has a certain maximum and minimum frequency, and works in between the optimal operation
area with the highest operating efficiencies. This is illustrated by the graph bellow.
1
2
3
Optimal
operation
area
8
7
3.
Max frequency
4
3
Min frequency
2
1
0
-7 -5 -3 -1 1 3 5 7 9 11 13
15
Outdoor temperature (C)
The partial load operation and optimal operation area can be illustrated by
a typical application in Paris
Typical application:
Location: Paris
Design temperature: -7C
Heat load: 7kW
Heating off temperature: 16C
800
1200
800
400
400
Operation hours
kWh heat output
Ta switch off
200
0
-10
-2 0
10
20
30
Daikin Altherma
6
5
Optimal
operation area
too small
4
3
7
6
Capacity (kW)
7
Capacity (kW)
5
4
Wide optimal
operation area at
relevant Ta
(-2C to 10C)
Resulting
in the best
possible
effficiencies
0
-7 -5 -3 -1 1 3 5 7 9 11 13 15
-7 -5 -3 -1 1 3 5 7 9 11 13 15
10
room temperatures.
1 Weather-dependent set-point control: Daikin Altherma maximises efficiency at every outdoor temperature through its
weather-dependent set-point control. This control logic will always keep the water temperatures as low as possible, to
maximise the heat pump efficiency for each specific outdoor temperature. This results in:
Higher heat pump efficiency with lower water temperatures
No unnecessary overheating, thereby delivering the temperatures required
Continuous heating at lower water temperatures, providing stable room temperatures
2 Inverter technology: lowering the compressor frequency with increasing outdoor temperatures, thus increasing
the efficiency
>
4.
38C
1
Floating
set-point
T set-point
(TLWC)
25C
-10C 16C
Ta
>
11
5.
Advantage compared
to tradional HP system
Conditions
Operating hours
per year
Yearly benefit
75W less
according to EN14511
5300 hours
398 kWh
20W less
in standby mode
3400 hours
70 kWh
60W less
when Ta below 4C
2800 hours
170 kWh
Advantage compared
to tradional HP system
Conditions
Operating hours
per year
Yearly benefit
90W less
according to EN14511
5300 hours
477 kWh
20W less
in standby mode
3400 hours
70 kWh
when Ta below 4C
2800 hours
160 kWh
13
new builds,
14
15
With the new 4kW unit, Daikin Altherma low temperature offers a full product line-up with a specifically dimensioned heat
pump system (compressor, modulating range, plate heat exchanger, ) to deliver the required capacities
Location: Paris
Design temperature: -7C
Heat load: 4kW
Heating off
temperature: 12C
800
1000
900
700
800
600
500
700
600
400
500
400
300
300
200
200
100
Operation hours
kWh heat output
Ta switch off
100
0
-10
-5
10
15
20
25
30
Daikin Altherma
6
5
4
6
Optimal operation area too small
and not in relevant Ta (-3C to 7C)
Capacity (kW)
Capacity (kW)
Low-energy houses have a lower space heating off temperature (12C) than normal
insulated houses (16C). This means that the most relevant outdoor temperaturerange for low-energy houses, shifts towards lower temperatures. A typical lowenergy house (see details below) has 80% of its total heat output in the outdoor
temperature range of -3C to 7C.
5
4
3
0
-7 -5 -3 -1 1 3 5 7 9 11 13 15
Outdoor temperature (C)
-7 -5 -3 -1 1 3 5 7 9 11 13 15
Outdoor temperature (C)
Resulting
in the best
possible
effficiencies
16
2.
MAXIMUM COMFORT
Daikin Altherma
low temperature:
one system for optimal
year-round comfort
possible
17
3.
Under-floor heating
25C 35C
35C 45C
The Daikin heat pump convector is specifically designed to offer optimal efficiencies and comfort for residential applications.
Small dimensions compared to low-temperature radiators
Low sound level, optimal for bedroom applications (down to 19 dBA)
High-capacity cooling with water temperatures down to 6 C
Low-temperature radiators
40C 55C
Tset
Thermo status
Space 1
low-temperature
radiator
45C
OFF
ON
ON
OFF
Space 2
under-floor heating
35C
OFF
ON
OFF
ON
OFF
45C
45C
35C
Heat pump
45C
600mm
45C
balancing
vessel
600mm
Low-temperature radiator
Console
Daikin
mixing valve
700mm
Under-floor
heating
35C
18
4.
19
Distributor
Hot gas pipe
Sealing
Sub-cool pass
20
Integrated
heating and
saving installation space and time
21
all in ONE
22
1.
Components
are accessible
from the front
23
2.
Compared to the traditional split-up version for a wall-mounted indoor unit and separate domestic hot water tank,
the integrated indoor unit greatly reduces the installation space required.
Hydrobox
1732 mm
DHW tank
VS
Space
reduced
by more
than
30%
580 mm
370 mm
950 mm + X
2
728 mm
72
8m
m
m
600 m
600 mm + 10 mm
clearance on both sides
3
Low installation height: both the 180l and 260l version come with a height of 173 cm. The required installation hight is less
than 2 m.
The compactness of the integrated indoor unit is emphasised by its sleek design and modern look, easily fitting with other
household appliances.
24
3.
25
4.
5.
EASY SERVICEABILITY
Graphical screen
with backlight
Detailed
Info
6.
On/Off
Confirm
Menu back
Navigational
buttons
Room thermostat:
The Daikin user interface can be installed in the living room using the room thermostat
function, which can additionally lower or raise the set-point water temperature in function
of actual room temperature, to even better match the set-point room temperature.
Integrated
solar unit
The integrated solar unit uses free energy from the sun and thus
supports the production of domestic hot water. Solar energy and heat
pumps complement each other ideally in this application.
Depending on your customers needs, an unpressurised and pressurised
solar system can be offered. The integrated solar unit is available in
a lightweight plastic tank and is combinable with a secondary heat
source as an option. With the app. easy control via your smartphone
is possible.
28
3.000
2.500
kWh
1.
2.000
1.500
1.000
500
Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct
Nov
Dec
29
2.
3.
4.
Wall mounted
offering flexibility for installation
and domestic hot connection
31
unit,
In certain situations the alternative set-up
of the wall-mounted indoor unit is the perfect solution.
The indoor unit including all hydraulic components can be combined
with a separate domestic hot water tank.
32
1.
FLEXIBLE SOLUTIONS
1. When no domestic hot water is required
in combination with the Daikin Altherma system
All hydraulic components are included in the heat pump
unit (circulating pump, expansion vessel, back-up heater,
etc), no need to look for third-party components
All hydraulic components and the PCB board, are
accessible from the front for easy serviceability
Compact unit: 890 mm (height) x 480 mm (width) x
344 mm (depth)
Small installation space as almost no side clearances are
required
Modern outlook easily fits in with other modern
household appliances.
2. The wall-mounted indoor unit can be combined with
a separate domestic hot water tank
EKHWS stainless steel tank: 150l, 200l or 300l
EKHWE enameled tank: 150l, 200l or 300l
33
34
35
3.
EASY SERVICEABILITY
In case something goes wrong, full-text error
messages will guide the end-user to take appropriate
action to try and resolve the problem. If the problem persists
and a site intervention is necessary, the service engineer
will be able to review the last 20 error occurrences.
Graphical screen
with backlight
Detailed
Information
Home
Menu back
Confirm
4.
Navigational buttons
36
Heat pump
in practice
1.
2.
SIMULATION SOFTWARE
The Daikin Altherma simulation software provides for every specific application and appropriate heat pump selection,
taking into account the needs of the building and specific climate data. An installer can provide the following data:
37
Technical specifications
DAIKIN ALTHERMA LOW TEMPERATURE
FLOOR STANDING UNIT
HEATING ONLY
INDOOR UNIT
Casing
Dimensions
Weight
Operation range
Colour
Material
Unit
Unit
Heating
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Power input
mm
kg
C
C
CDB
C
dBA
dBA
115
Nom.
Max.
kW
kW
kW
kW
kW
Unit
HeightxWidthxDepth
Unit
Heating
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
116/126
-25~25
116/126
EHVH16S18CB3V
EHVH16S26CB9W
EHVH16S18CB3V
EHVH16S26CB9W
EHVH16S18CB3V
EHVH16S26CB9W
EHVH16S18CB3V
EHVH16S26CB9W
EHVH16S18CB3V
EHVH16S26CB9W
EHVH16S18CB3V
EHVH16S26CB9W
120/129
120/129
120/129
ERLQ011CW1
ERLQ014CW1
ERLQ016CW1
11.38
14.55
3.43
4.24
16.10
White
Precoated sheet metal
1,732x600x728
120/129
120/129
120/129
-25~35
15~55
-20~35
25~60
42
28
mm
kg
CWB
CDB
EHVH08S18CB3V
EHVH08S26CB9W
-25~35
ERLQ004CV3
Min.
Nom.
Max.
Heating
COP
Dimensions
Weight
Operation range
EHVH08S18CB3V
EHVH08S26CB9W
EHVH04S18CB3V
47
33
ERLQ006CV3
1.80 (1) / 1.80 (2)
6.00 (1) / 5.67 (2)
8.35 (1) / 7.95 (2)
1.27 (1) / 1.59 (2)
4.74 (1) / 3.56 (2)
ERLQ008CV3
ERLQ011CV3
ERLQ014CV3
735x832x307
54
ERLQ016CV3
16.00 (1) / 15.20 (2)
12.30 (3) / 11.35 (4)
3.81 (1) / 4.66 (2)
5.49 (3) / 6.43 (4)
4.20 (1) / 2.24 (3) /
3.26 (2) / 1.79 (4)
2.64
4.31
16.10
4.20
1,345x900x320
56
113
114
-25~25
-25~35
-25~35
-20~35
R-410A
kg
dBA
dBA
Hz/V
A
1.45
1.60
61
48
3.4
62
49
V3/1~/50/230
20
64
51
66
52
40
64
51
W1/3N~/50/400
20
66
52
(1) Condition 1: cooling Ta 35C - LWE 18C (DT = 5C); heating Ta DB/WB 7C/6C - LWC 35C (DT = 5C) (2) Condition 2: cooling Ta 35C - LWE 7C ( DT = 5C); heating Ta DB/WB 7C/6C - LWC 45C ( DT = 5C ) (3) Condition 3: heating Ta DB -7C (RH85%) - LWC 35C
(4) Condition 4: heating Ta DB -7C (RH85%) - LWC 45C
38
Colour
Material
Unit
Unit
Heating
Cooling
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Cooling capacity
Power input
mm
kg
C
C
CDB
C
CDB
C
dBA
dBA
EHVX04S18CB3V
EHVX08S18CB3V
EHVX08S26CB9W
EHVX08S18CB3V
EHVX08S26CB9W
115
117/126
-25~25
117/126
Cooling
kW
kW
kW
kW
kW
kW
kW
kW
Nom.
Max.
Nom.
COP
EER
Dimensions
Weight
Operation range
mm
kg
CWB
CDB
CDB
EHVX16S18CB3V
EHVX16S26CB9W
EHVX16S18CB3V
EHVX16S26CB9W
121/129
121/129
-25~35
15~55
121/129
10~46
5~22
-25~35
-20~35
25~60
47
42
28
47
33
ERLQ006CV3
1.80 (1) / 1.80 (2)
6.00 (1) / 5.67 (2)
8.35 (1) / 7.95 (2)
2.50 (1) / 2.50 (2)
6.76 (1) / 4.84 (2)
1.27 (1) / 1.59 (2)
1.96 (1) / 2.07 (2)
4.74 (1) / 3.56 (2)
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Cooling
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
EHVX16S18CB3V
EHVX16S26CB9W
15~55
10~43
ERLQ004CV3
Min.
Nom.
Max.
Min.
Nom.
Heating
EHVX16S18CB3V EHVX16S18CB3V
EHVX16S26CB9W EHVX16S26CB9W
White
Precoated sheet metal
1,732x600x728
121/129
121/129
121/129
-25~35
EHVX16S18CB3V
EHVX16S26CB9W
54
ERLQ008CV3
ERLQ011CV3
ERLQ014CV3
ERLQ016CV3
ERLQ011CW1
ERLQ014CW1
ERLQ016CW1
11.38
14.55
-
16.10
11.72
2.64
12.55
3.43
5.09
4.24
13.12
3.83
2.47
2.29
56
4.31
4.31
113
5.74
4.20
114
-25~25
10~43
-25~35
-25~35
10.0~46.0
-20~35
R-410A
kg
dBA
dBA
dBA
dBA
Hz/V
A
1.45
1.60
3.4
61
62
63
64
48 (3)
48 (3)
64
49 (3)
66
69
52
54
66
49 (3)
50 (3)
50
V3/1~/50/230
51
52
20
64
64
66
69
52
54
66
51
50
52
W1/3N~/50/400
20
40
(1) Condition 1: cooling Ta 35C - LWE 18C (DT = 5C); heating Ta DB/WB 7C/6C - LWC 35C (DT = 5C) (2) Condition 2: cooling Ta 35C - LWE 7C ( DT = 5C); heating Ta DB/WB 7C/6C - LWC 45C ( DT = 5C )
(3) Condition 3: heating Ta DB -7C (RH85%) - LWC 35C (4) Condition 4: heating Ta DB -7C (RH85%) - LWC 45C
Colour
Material
Unit
Unit
Heating
Cooling
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Nom.
Nom.
Heating
Cooling
Nom.
Nom.
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Cooling
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
mm
kg
C
C
CDB
C
CDB
C
dBA
dBA
kW
kW
kW
kW
EHVX16S18CB3V
EHVX16S26CB9W
EHVX16S18CB3V
EHVX16S26CB9W
121/129
121/129
ERHQ011BV3
11.2 (1) / 10.30 (2)
13.9 (1) / 10.0 (2)
2.55 (1) / 3.17 (2)
3.86 (1) / 3.69 (2)
4.39 (1) / 3.25 (2)
3.60 (1) / 2.71 (2)
ERHQ014BV3
14.0 (1) / 13.1 (2)
17.3 (1) / 12.5 (2)
3.26 (1) / 4.04 (2)
5.86 (1) / 5.39 (2)
4.29 (1) / 3.24 (2)
2.95 (1) / 2.32 (2)
1,170x900x320
103
-20~35
mm
kg
CWB
CDB
CDB
kg
dBA
dBA
dBA
dBA
Hz/V
A
(1)DB/WB 7C/6C - LWC 35C (DT=5C) - (2) DB/WB 7C/6C - LWC 45C (Dt=5C)
EHVX16S18CB3V
EHVX16S18CB3V
EHVX16S26CB9W
EHVX16S26CB9W
White
Precoated sheet metal
1,732x600x728
121/129
121/129
-25~35
15~55
10~46
5~22
-20~35
25~60
47
33
ERHQ016BV3
16.0 (1) / 15.2 (2)
17.8 (1) / 13.1 (2)
3.92 (1) / 4.75 (2)
6.87 (1) / 5.95 (2)
4.08 (1) / 3.20 (2)
2.59 (1) / 2.20 (2)
ERHQ011BW1
11.32 (1) / 10.98 (2)
15.05 (1) / 11.72 (2)
2.63 (1) / 3.24 (2)
4.53 (1) / 4.31 (2)
4.30 (1) / 3.39 (2)
3.32 (1) / 2.72 (2)
EHVX16S18CB3V
EHVX16S26CB9W
EHVX16S18CB3V
EHVX16S26CB9W
121/129
121/129
ERHQ014BW1
14.50 (1) / 13.57 (2)
16.06 (1) / 12.55 (2)
3.42 (1) / 4.21 (2)
5.43 (1) / 5.08 (2)
4.24 (1) / 3.22 (2)
2.96 (1) / 2.47 (2)
1,345x900x320
108
-25~35
ERHQ016BW1
16.05 (1) / 15.11 (2)
16.76 (1) / 13.12 (2)
3.82 (1) / 4.69 (2)
6.16 (1) / 5.73 (2)
4.20 (1) / 3.22 (2)
2.72 (1) / 2.29 (2)
10~46
-20~35
R-410A
2.7
64
64
49
50
66
51
52
V3/1~/50/230
32
2.95
66
69
53
54
64
64
66
51
50
52
W1/3N~/50/400
20
66
69
52
54
39
EHSX04P30A
Colour
Unit
Unit
Water side
Water side
Water side
Sound power level Nom.
Sound pressure level Nom.
OUTDOOR UNIT
Heating capacity
Cooling capacity
COP
EER
Dimensions
Weight
Operation range
HeightxWidthxDepth
Min.~Max.
Min.~Max.
Min.~Max.
Nom.
Nom.
mm
kg
C
C
C
dBA
dBA
kW
kW
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Cooling
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
mm
kg
CWB
CDB
CDB
kg
dBA
dBA
dBA
dBA
Hz/V
A
EHSX08P30A
EHSX08P50A
EHSX16P50A
Tank: white RAL 9003 / Top cover: steel grey RAL 7011
1,950x615x595
1,940x790x790
87
114
116
15~55
5~22
25~80
42
66
28
32
ERLQ004CV3
ERLQ006CV3
ERLQ008CV3
ERLQ006CV3
ERLQ008CV3
ERLQ011CV3/CW1 ERLQ014CV3/CW1 ERLQ016CV3/CW1
4.53 (1) / 3.47 (2) 6.06 (1) / 4.6 (2) 7.78 (1) / 5.51 (2) 6.06 (1) / 4.6 (2) 7.78 (1) / 5.51 (2) 11.8 (1) / 7.7 (2) 14.8 (1) / 9.6 (2) 15.3 (1) / 10.1 (2)
4.42 (3)
5.22 (3)
15.1 (3)
16.1 (3)
16.8 (3)
5.23 (1) / 4.07 (2) 4.65 (1) / 3.64 (2) 4.6 (1) / 3.54 (2) 4.65 (1) / 3.64(2) 4.6 (1) / 3.54 (2) 4.47 (1) / 3.29 (2) 4.27 (1) / 3.22 (2) 4.1 (1) / 3.15 (2)
4.21 (3)
3.65 (3)
3.32 (3)
2.96 (3)
2.72 (3)
735x832x307
1,345x900x320
54
56
113
114
-25~25
-25~35
10~43
10.0~46.0
-25~35
-20~35
R-410A
1.45
1.60
3.4
61
62
61
62
64
66
63
64
66
69
48
49
48
49
51
52
48
49
50
49
50
52
54
V3/1~/50/230
W1/3N~/50/400
20
EHSXB04P30A
Colour
Unit
Unit
Water side
Water side
Water side
Sound power level Nom.
Sound pressure level Nom.
OUTDOOR UNIT
Heating capacity
Cooling capacity
COP
EER
Dimensions
Weight
Operation range
HeightxWidthxDepth
Min.~Max.
Min.~Max.
Min.~Max.
Nom.
Nom.
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Cooling
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
(1) Condition 1: heating Ta 7C / LWC 35C
(2): heating Ta 2C / LWC 35C
(3) Condition 3: cooling Ta 35C / LWC 18C
mm
kg
C
C
C
dBA
dBA
kW
kW
mm
kg
CWB
CDB
CDB
kg
dBA
dBA
dBA
dBA
Hz/V
A
42
28
EHSXB08P30A
EHSXB08P50A
EHSXB16P50A
Tank: white RAL 9003 / Top cover: steel grey RAL 7011
1,950x615x595
1,940x790x790
92
119
121
15~55
5~22
25~80
42/62
66
28/29
32
40
EHBH04CB3V
Colour
Material
Unit
Unit
Heating
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Power input
mm
kg
C
C
CDB
C
dBA
dBA
EHBH08CB3V
EHBH08CB9W
44
EHBH08CB3V
EHBH08CB9W
kW
kW
kW
kW
kW
Nom.
Max.
COP
Dimensions
Weight
Operation range
Unit
HeightxWidthxDepth
Unit
Heating
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
mm
kg
CWB
CDB
kg
dBA
dBA
Hz/V
A
EHBH16CB3V
EHBH16CB3V
EHBH16CB3V
EHBH16CB9W EHBH16CB9W EHBH16CB9W
White
Precoated sheet metal
890x480x344
47/48
-25~35
46/48
-25~25
EHBH16CB3V
EHBH16CB9W
15 (4)~55 (4)
EHBH16CB3V
EHBH16CB9W
15~55
-25~35
-20~35
25~80
40
26
47
33
ERLQ004CV3
Min.
Nom.
Max.
Heating
EHBH16CB3V
EHBH16CB9W
ERLQ006CV3
ERLQ008CV3
1.80 (1) / 1.80 (2)
4.40 (1) / 4.03 (2)
6.00 (1) / 5.67 (2)
7.40 (1) / 6.89 (2)
5.12 (1) / 4.90 (2)
8.35 (1) / 7.95 (2) 10.02 (1) / 9.35 (2)
0.87 (1) / 1.13 (2)
1.27 (1) / 1.59 (2)
1.66 (1) / 2.01 (2)
5.04 (1) /
4.74 (1) /
4.45 (1) /
3.58 (2)
3.56 (2)
3.42 (2)
735x832x307
54
56
-25~25
-25~35
1.45
1.60
61
48 (3)
62
49 (3)
20
ERLQ011CV3
ERLQ014CV3
ERLQ016CV3
ERLQ011CW1
ERLQ014CW1
ERLQ016CW1
16.0 / 15.2
3.92 / 4.75
4.08 / 3.20
66
53
(1) Condition 1: cooling Ta 35C - LWE 18C (DT = 5C); heating Ta DB/WB 7C/6C - LWC 35C (DT = 5C) (2) Condition 2: cooling Ta 35C - LWE 7C ( DT = 5C); heating Ta DB/WB 7C/6C - LWC 45C ( DT = 5C )
(3) Condition 3: heating Ta DB -7C (RH85%) - LWC 35C (4) Condition 4: heating Ta DB -7C (RH85%) - LWC 45C
HEATING ONLY
INDOOR UNIT
Casing
Dimensions
Weight
Operation range
EHBH16CB3V
EHBH16CB9W
Colour
Material
Unit
Unit
Heating
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Nom.
Heating
Nom.
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Sound pressure level Heating
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
mm
kg
C
C
CDB
C
dBA
dBA
kW
kW
EHBH16CB3V
EHBH16CB9W
47/48
47/48
ERHQ011BW1
11.32 (1) / 10.98 (2)
2.63 (1) / 3.24 (2)
4.30 (1) / 3.39 (2)
ERHQ014BW1
14.50 (1) / 13.57 (2)
3.42 (1) / 4.21 (2)
4.24 (1) / 3.22 (2)
mm
kg
CWB
CDB
kg
dBA
dBA
Hz/V
A
(1)DB/WB 7C/6C - LWC 35C (DT=5C) - (2) DB/WB 7C/6C - LWC 45C (Dt=5C)
64
51
EHBH16CB3V
EHBH16CB9W
EHBH16CB3V
EHBH16CB9W
White
Precoated sheet metal
890x480x344
47/48
47/48
-25~35
15~55
-20~35
25~80
47
33
EHBH16CB3V
EHBH16CB9W
EHBH16CB3V
EHBH16CB9W
47/48
47/48
ERHQ016BW1
ERHQ011BV3
ERHQ014BV3
16.05 (1) / 15.11 (2)
11.32 (1) / 10.98 (2)
14.50 (1) / 13.57 (2)
3.82 (1) / 4.69 (2)
2.63 (1) / 3.24 (2)
3.42 (1) / 4.21 (2)
4.20 (1) / 3.22 (2)
4.30 (1) / 3.39 (2)
4.24 (1) / 3.22 (2)
1,345x900x320
108
-25~35
-20~35
R-410A
2.95
66
64
52
51
W1/3N~/50/400
20
ERHQ016BV3
16.05 (1) / 15.11 (2)
3.82 (1) / 4.69 (2)
4.20 (1) / 3.22 (2)
66
52
41
Colour
Material
Unit
Unit
Heating
Cooling
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Cooling capacity
Power input
mm
kg
C
C
CDB
C
CDB
C
dBA
dBA
EHBX04CB3V
EHBX08CB3V
EHBX08CB9W
EHBX08CB3V
EHBX08CB9W
44
46/48
-25~25
46/48
Cooling
kW
kW
kW
kW
kW
kW
kW
kW
Nom.
Max.
Nom.
COP
EER
Dimensions
Weight
Operation range
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Cooling
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
mm
kg
CWB
CDB
CDB
kg
dBA
dBA
dBA
dBA
Hz/V
A
EHBX16CB3V EHBX16CB3V
EHBX16CB9W EHBX16CB9W
White
Precoated sheet metal
890x480x344
47/48
47/48
47/48
-25~35
EHBX16CB3V
EHBX16CB9W
EHBX16CB3V
EHBX16CB9W
EHBX16CB3V
EHBX16CB9W
47/48
47/48
-25~35
15~55
47/48
ERLQ011CW1
ERLQ016CW1
ERLQ014CW1
11.32 / 10.98
14.50 / 13.57
16.05 / 15.11
16.06 / 12.55
3.42 / 4.21
5.43 / 5.08
4.24 / 3.22
16.76 / 13.12
3.82 / 4.69
2.96 / 2.47
1,345x900x320
108
2.72 / 2.29
15~55
10~43
10~46
5~22
-25~35
-20~35
25~80
40
26
ERLQ004CV3
Min.
Nom.
Max.
Min.
Nom.
Heating
EHBX16CB3V
EHBX16CB9W
47
33
ERLQ006CV3
ERLQ008CV3
1.80 (1) / 1.80 (2)
6.00 (1) / 5.67 (2)
7.40 (1) / 6.89 (2)
8.35 (1) / 7.95 (2) 10.02 (1) / 9.53 (2)
2.50 (1) / 2.50 (2)
6.76 (1) / 4.84 (2)
6.86 (1) / 5.3 (2)
1.27 (1) / 1.59 (2)
1.66 (1) / 2.01 (2)
1.96 (1) / 2.07 (2) 2.01 (1) / 2.34 (2)
4.74 (1) /
4.45 (1) /
3.56 (2)
3.42 (2)
3.45 (1) / 2.34 (2) 3.42 (1) / 2.29 (2)
735x832x307
56
-25~25
10~43
-25~35
1.45
ERLQ011CV3
ERLQ014CV3
15.05 / 11.72
2.63 / 3.24
3.32 / 2.72
R-410A
3.4
61
62
63
48 (3)
49 (3)
4.53 / 4.31
4.30 / 3.39
2.95
64
64
49 (3)
50 (3)
6.16 / 5.73
4.20 / 3.22
-25~35
10.0~46.0
-20~35
1.60
48 (3)
ERLQ016CV3
66
69
52
54
66
51
50
52
V3/1~/50/230
40
20
64
64
66
69
52
54
66
51
50
52
20
(1) Condition 1: cooling Ta 35C - LWE 18C (DT = 5C); heating Ta DB/WB 7C/6C - LWC 35C (DT = 5C) (2) Condition 2: cooling Ta 35C - LWE 7C ( DT = 5C); heating Ta DB/WB 7C/6C - LWC 45C ( DT = 5C )
(3) Condition 3: heating Ta DB -7C (RH85%) - LWC 35C (4) Condition 4: heating Ta DB -7C (RH85%) - LWC 45C
INDOOR UNIT
Casing
Dimensions
Weight
Operation range
Colour
Material
Unit
Unit
Heating
Cooling
Domestic hot
water
HeightxWidthxDepth
Ambient
Water side
Ambient
Water side
Ambient
Water side
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Nom.
Nom.
Heating
Cooling
Nom.
Nom.
HeightxWidthxDepth
Unit
Unit
Heating
Min.~Max.
Cooling
Min.~Max.
Domestic hot water Min.~Max.
Refrigerant
Type
Charge
Sound power level Heating
Nom.
Cooling
Nom.
Sound pressure
Heating
Nom.
level
Cooling
Nom.
Power supply
Name/Phase/Frequency/Voltage
Current
Recommended fuses
mm
kg
C
C
CDB
C
CDB
C
dBA
dBA
kW
kW
kW
kW
EHBX16CB3V
EHBX16CB9W
47/48
47/48
-25~35
15~55
EHBX16CB3V
EHBX16CB9W
White
Precoated sheet metal
890x480x344
47/48
47/48
EHBX16CB3V
EHBX16CB9W
EHBX16CB3V
EHBX16CB9W
47/48
-25~35
15~55
47/48
ERHQ014BW1
14.50 / 13.57
16.06 / 12.55
3.42 / 4.21
5.43 / 5.08
4.24 / 3.22
2.96 / 2.47
1,345x900x320
108
-25~35
ERHQ016BW1
16.05 / 15.11
16.76 / 13.12
3.82 / 4.69
6.16 / 5.73
4.20 / 3.22
2.72 / 2.29
10~46
5~22
-20~35
25~80
47
33
ERHQ011BV3
11.2 (3) / 10.30 (4)
13.9 (2) / 10.0 (1)
2.55 (3) / 3.17 (4)
3.86 (2) / 3.69 (1)
4.39 (3) / 3.25 (4)
3.60 (2) / 2.71 (1)
ERHQ014BV3
14.0 (3) / 13.1 (4)
17.3 (2) / 12.5 (1)
3.26 (3) / 4.04 (4)
5.86 (2) / 5.39 (1)
4.29 (3) / 3.24 (4)
2.95 (2) / 2.32 (1)
1,170x900x320
103
-20~35
mm
kg
CWB
CDB
CDB
kg
dBA
dBA
dBA
dBA
Hz/V
A
EHBX16CB3V
EHBX16CB9W
ERHQ016BV3
16.0 (3) / 15.2 (4)
17.8 (2) / 13.1 (1)
3.92 (3) / 4.75 (4)
6.87 (2) / 5.95 (1)
4.08 (3) / 3.20 (4)
2.59 (2) / 2.20 (1)
ERHQ011BW1
11.32 / 10.98
15.05 / 11.72
2.63 / 3.24
4.53 / 4.31
4.30 / 3.39
3.32 / 2.72
10~46
-20~35
R-410A
2.7
64
64
49
50
66
51
52
V3/1~/50/230
32
2.95
66
69
53
54
(1)DB/WB 7C/6C - LWC 35C (DT=5C) - (2) DB/WB 7C/6C - LWC 45C (Dt=5C) (3) Condition 3: heating Ta DB -7C (RH85%) - LWC 35C (4) Condition 4: heating Ta DB -7C (RH85%) - LWC 45C
64
64
66
51
50
52
W1/3N~/50/400
20
66
69
52
54
42
Heat exchanger
Booster heater
Power supply
Width
Depth
Empty
Unit
Water volume
Material
Maximum water temperature
Insulation
Heat loss
Quantity
Tube material
Capacity
Phase/Frequency/Voltage
EKHWS150B3V3
EKHWS200B3V3
mm
mm
kg
l
37
150
45
200
C
kWh/24h
1.55
1.77
kW
Hz/V
EKHWS200B3Z2
EKHWS300B3Z2
45
200
59
300
1.77
2.19
1~/50/230
EKHWE150A3V3
mm
kg
l
C
kWh/24h
kW
Hz/V
EKHWS300B3V3
Neutral white
Epoxy-coated mild steel
580
580
59
300
Stainless steel (DIN 1.4521)
85
2.19
1
Duplex steel LDX 2101
3
EKHWE200A3V3
545
80
150
104
200
1.7
1.9
2~/50/400
EKHWE300A3V3
RAL9010
Epoxy coated steel
660
140
300
75
2.5
3.0
EKHWE200A3Z2
EKHWE300A3Z2
545
104
200
660
140
300
1.9
2.5
1~/50/230
2~/50/400
Weight
Tank
Heat exchanger
Height
Width
Depth
Empty
Unit
Water volume
Maximum water temperature
Insulation
Heat loss
Domestic hot
Tube material
water
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Charging
Tube material
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
Auxiliary solar
Tube material
heating
Face area
Internal coil volume
Operating pressure
Average specifc thermal output
mm
mm
mm
kg
l
C
kWh/24h
EKHWP300B
1,640
595
615
59
300
EKHWP500B
1,640
790
790
93
500
85
1.3
1.4
Stainless steel
m
l
bar
W/K
5.8
27.9
6
29
6
2,790
2,900
Stainless steel
m
l
bar
W/K
2.7
13.2
3.8
18.5
3
1,300
1,800
Stainless steel
m
l
bar
W/K
0.5
2.3
3
280
Power supply
HeightxWidthxDepth
Unit
Zero loss collector efficiency 0
Type
Power consumption
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
Voltage
mm
%
W
EKSRPS3
On side of tank
815x230x142
Digital temperature difference controller with plain text display
2
Pt1000
PTC
PTC
Voltage signal (3.5V DC)
230
43
Power supply
HeightxWidthxDepth
Unit
Zero loss collector efficiency 0
Type
Power consumption
Solar panel temperature sensor
Storage tank sensor
Return flow sensor
Feed temperature and flow sensor
Voltage
EKSOLHW
770x305x270
8
1~35
27
1~/50/220-240
INDOOR UNIT
mm
kg
C
dBA
%
Hz/V
EKSDSR1
On wall
332x230x145
Digital temperature difference controller with plain text display
2
Pt1000
PTC
PTC
Voltage signal (3.5V DC)
230
mm
%
W
SOLAR COLLECTOR
Solar collector
Dimensions
Weight
Volume
Surface
Coating
Absorber
Glazing
Allowed roof angle
Operating pressure
Stand still temperature
Thermal performance
Outer
Aperture
Absorber
mm
kg
l
m
m
m
Min.~Max.
Max.
Max.
Zero loss collector efficiency 0
bar
C
%
Unit
Unit
HeightxWidthxDepth
EKSH26P
1,300x2,000x85
42
2.1
2.6
2.350
2.360
EKSV21P
EKSV26P
2,000x1,006x85
2,000x1,300x85
35
42
1.3
1.7
2.01
2.6
1.79
2.35
1.8
2.36
Micro-therm (absorption max.96%, Emission ca. 5% +/-2%)
Harp-shaped copper pipe register with laser-welded highly selective coated aluminium plate
Single pane safety glass, transmission +/- 92%
15~80
6
200
-
Total capacity
Nom.
Total capacity
Nom.
Sensible capacity Nom.
Heating
Nom.
Cooling
Nom.
HeightxWidthxDepth
Unit
Unit
Drain/OD/Inlet/Outlet
Heating
Nom.
Cooling
Nom.
Phase/Frequency/Voltage
kW
Btu/h
kW
kW
kW
kW
mm
kg
mm/inch
dBA
dBA
Hz/V
FWXV15A
1.5
5,100
1.2
0.98
0.013
0.013
FWXV20A
2.0
6,800
1.7
1.4
0.015
0.015
600x700x210
15
18/G 1/2/G 1/2
19
19
29
29
1~/50/60/220-240/220
ROOM THERMOSTAT
Wireless / Wired room thermostat
Dimensions
Unit
Thermostat
Receiver
Weight
Unit
Thermostat
Receiver
Ambient
Storage
temperature
Operation
Temperature
Heating
setting range
Cooling
Clock
Regulation function
Power supply
Voltage
Thermostat
Receiver
Frequency
Phase
Connection
Type
Thermostat
Receiver
Maximum distance Indoor
to receiver
Outdoor
HeightxWidthxDepth mm
Height/Width/Depth mm
Height/Width/Depth mm
g
g
g
Min./Max.
C
Min./Max.
C
Min./Max.
C
Min./Max.
C
Voltage
Voltage
V
V
V
Hz
m
m
EKRTR1
87/125/34
170/50/28
210
125
EKRTWA
87x125x34
215
-20/60
0/50
4/37
4/37
Yes
Proportional band
Daikin
Altherma
Daikin in general
&
A clean environment
In producing your customers climate-control system, we strive for
sustainable energy consumption, product recycling and waste reduction.
Daikin rigorously applies the principles of eco-design, thus restricting the use
of materials that are harmful to our environment.
The present leaflet is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this leaflet to the best of its knowledge. No express or
implied warranty is given for the completeness, accuracy, reliability or fitness
for particular purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice. Daikin Europe
N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest
sense, arising from or related to the use and/or interpretation of this leaflet. All
content is copyrighted by Daikin Europe N.V.
FSC
ECPEN14-724
Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende
Today, Daikin leads the way towards more efficient, cost-effective and environmentally friendly comfort solutions, introducing
products optimised for all seasons. In fact, Daikin products reduce energy and costs in a smart way. They are designed to
perform under all conditions and reflect the actual performance you can expect over an entire heating and cooling season.
So, with Daikin you make the right choice for your wallet... and the environment.