Beruflich Dokumente
Kultur Dokumente
Patents Pending
THE VALVE
F
Square pattern;
M6 x 15/.59 deep
H
Square pattern;
M6 thru
FLOW (Li/day)
Standard Valve
102 / 4.00
VALVE
at 100% FS
6 / 0.25
VALVE
below 100% FS
K (Outlet)
P ACROSS VALVE
C Max
L (Inlet)
E
J
Note: Inlet can be oriented
in 90 increments. Shown
as shipped
D
I
M (Port flat)
MODEL
HTD-10000
THE SYSTEM
HTD-5000
DIMENSIONS (mm/in)
C
D
E
F
G
H
I
157
184
269
88
113
41
31
57
88
6.18
7.25
10.60
3.48
4.44
1.62
1.20
2.25
3.48
184
269
75
113
41
31
57
88
156
6.15
7.25
10.60
2.96
4.44
1.62
1.20
2.25
3.48
A
K
3
13
0.50
13
0.50
AE MP
L
3
8
1
NPT
4
AE MP
M
42
8
1.64
35
1
NPT
1.68
4
N
43
1.69
43
1.69
chemical injection
control valve 3-Way
Valve
Filter
Check Isolation
Valve
Valve
SF
Isolation
Valve
Chemical Out
to Process*
To
Flow Meter
SF
Tank
BPR
PRV
Pump
Pressure
Gauge
EXP
SF
Chemical
to Valves
Filter
Pulsation
Damper
(Expansion
Compensator)
SF
Notes: For systems not using a positive displacement pump the pulsation damper and back pressure regulator are not required.
FLOW TABLES
HTD 5000
Working Pressure
Current Model
500
Lowest Flow
V = Viton
K = Kalrez Equivalent
E = EPDM
A
SN
Highest Water Flow
Range 1:
Range 2:
15 to 1500 GPD
56.8 to 5678 l/day
Qwater x V
Sgfluid
Where:
Qfs fluid =
500 x 0.58
= 306 Gal/day
0.9
www.skoflo.com
Patents Pending
Ver. 060712
Viscosity
CS
Factor
V
1
10
20
30
40
50
60
70
80
90
100
200
300
400
500
600
700
800
900
1000
1.00
1.00
0.97
0.92
0.89
0.86
0.83
0.81
0.79
0.77
0.74
0.63
0.53
0.44
0.39
0.34
0.30
0.26
0.24
0.23