DUST COLLECTOR CONTROLS

Intelligent, AC-Input, Pulse Cleaning


of Bag House Dust Collectors
Models DNC-T2310 and DNC-T2320
FEATURES

On-board differential pressure sensor


4 - 20 mA output for DP
8 character alpha-numeric display
Microprocessor based control for stable
timing from -40C to 65C
Enhanced timer option: monitor additional devices; record dust collector
data; network timers together remote
network monitor; remote network control
RS232 port for remote monitor and control
Automatic output setup capability
Expanded cycle mode allows additional
dust collector controllers to expand output capabilities
High pressure alarm indication
Output fault detection
Alarm output contacts
Alarm input sensors
Pulse time: line synchronized to eliminate 8 ms triac turn off variation per
output
10 A 400 V output triacs for maximum
protection against output shorts; 200 VA
load rating
Conformally coated for protection
against vibration, humidity, and contamination
Metal chassis provided: for mounting
directly into nema 4 box
Timer functionally tested to eliminate
field failures
Input protection: 30 joule metal oxide
varistor
One year warranty: warranted to be
free from defects in materials or workmanship for one year from date of manufacture
File #E65038

Models T2310 and T2320 are microprocessor-based bag house filter controllers
which combine a ten or twenty output
sequencer with a solid state differential
pressure sensor. This offers a small, lowcost replacement to the separate solid state
sequencer and pressure gauge combination
most often used in on-demand pulse jet
cleaning systems. These controllers will
sense the pressure difference across the
filters of a bag house and initiate a cleaning

cycle when the filters start to impede the air


flow. When the pressure drops to normal the
controller will stop cycling.
Standard Operating Logic: The timers can
operate in the following modes:
Auto output: only configured outputs will
be pulsed. Output faults will be detected
and indicated.
Manual output: outputs will recycle after
last output used.
Output step: a single cleaning pulse can
be initiated by pressing the output step
key regardless of pressure input.
Continuous cycle: controller will cycle
indefinitely when the bypass/cycle down
input is shorted.
Cycle down: the outputs will be pulsed
through a user seleced number of complete cycles when the bypass/cycle down
input is shorted. This cycle will occur
regardless of pressure input.
Expanded output mode: controller will
cycle to output #10 or #20, then will initiate an extended output mode via the
alarm input and output terminals to
NCCs DNC-T2000 series dust collector controllers. This will facilitate systems which require greater than 10 or 20
outputs.
Standard Timer Operation Status
Indication: The Timer can show the following information on its 8-character alphanumeric display during normal operation:
DP from 0 to 15 water column
High or Low DP Alarms
Solenoid Fault Conditions
Current Output being Pulsed
Auxiliary Alarm Input Closures
Upon occurance of any alarm event, the
alarm status is reported on the display
along with the output number that was
pulsed during the time of the event.
Alarm Outputs: The isolated Alarm
Output contacts will close for alarm
conditions such as output faults,
high pressure alarm, warm-up failure,
etc. During an alarm condition, a
corresponding message is displayed.
Alarm Input: A closure across the Alarm
Input terminals will be indicated on
the display as well as initiate the Alarm
Output.

In addition to the standard operation of the T2310 and T2320,


an enhanced operation option
is available with the use of the
DNC-T2300-I/O Remote Input/
Output module in conjunction
with the DNC-T2300-DSP Remote
Annunciator Panel. The T2310
and T2320 Timers along with the
DNC-T2300-I/O constitutes the
Enhanced Timer system which
allows the user to monitor and
record the data parameters associated with a dust collector system.
This system can range in size from
1 to 255 dust collectors, all reporting to a central location, the DNCT2300-DSP.
Enhanced Timer Operation
Status Indication: The Timer can
show the following information on
its 8 character alpha-numeric display during normal operation:
DP from 0 to 15 water column
High or Low DP Alarms
Solenoid Fault Conditions
Current Output being Pulsed
Auxiliary Alarm Input Closures
DNC-T2300-I/O Analog Input
Status
DNC-T2300-I/O Alarm Input
Closures
Upon occurance of any alarm
event, the alarm status is reported
on the display along with the output number that was pulsed during
the time of the event.

4-16

DUST COLLECTOR CONTROLS

SPECIFICATIONS
FACTORY DEFAULT SETTINGS
Lo Pressure = 2 water column
HI Pressure = 4 water column
Alarm Pressure = 14 water column
Output Quantity = 10
Off Time = 15 seconds
On Time = 0.10 seconds
Output Configuration = Manual
I/O Expansion = No
INPUTS
Voltage: 105 -135 VAC, 50/60 Hz.
Maximum Ratings at 135 VAC Input Voltage:
Power Consumption: 10 VA, without loads
DNC-T2310:
Bypass Switch Open Circuit Voltage: 24 VDC
Bypass Switch Short Circuit Current: 4.3 mA
Alarm Inputs 1-3:
Open Circuit Voltage: 24 VDC
Short Circuit Current: 4.3 mA
DNC-T2320:
Bypass Switch Open Circuit Voltage: 24 VDC
Bypass Switch Short Circuit Current: 4.3 mA
Alarm Inputs 1-3:
Open Circuit Voltage: 24VDC.
Short Circuit Current: 4.3 mA
Auxiliary Input #4: 90-135 VAC, 50/60 Hz;
6.6 mA at 135 VAC

AIR PRESSURE MEASUREMENT


Sensor Type: Silicon piezoresistive transducer
with dual inlets
Measurement Range: 0.0 to 15.0 of water
Accuracy: 2% of full scale at 25C 6% of full
scale over temperature and voltage range
Maximum Continuous Pressure: 10 psi
DISPLAY
Type: 8-character, 16-segment vacuum fluorescent display; characters .2 high, alpha-numeric
TIMING:
Solenoid ON Time Range: .01-.50 sec.
Solenoid OFF Time Range: 7 -999 sec.
Timing Accuracy: -2 ms, +10 ms or 1%, whichever is greater; Solenoid ON Time is synchronized
to the AC line
OUTPUTS
Maximum Solenoid Output: 200 VA or W at
max. duty cycle
Solenoid Output Voltage: Input voltage 2.5 VAC
at 200 VA load
Solenoid Output Type: Solid state triac
Solenoid Output Short Circuit Protection:
3 AG fast acting
120 V units: 3 A/250 VAC fuse
240 V units: 1.5 A/250 VAC fuse
DNC-T2310:
Alarm Output Type: 1-FORM A relay contact
Alarm Output Rating: 3 A at 120/240 VAC

DNC-T2320:
Alarm Output Type: 1-FORM A relay
contact
Alarm Output Rating: 3 A at 120/240
VAC
Aux. Output #4 Type: 1-FORM A relay
contact
Aux. Output #4 Rating: 3 A at 120/240
VAC
Current Loop:
Type: 4 - 20 mA current loop, current
is sourced by the controller. Signal
represents 0 to 15 inches of differential
pressure (DP)
Accuracy: .3 mA of displayed pressure
SERIAL COMMUNICATIONS
Type: RS232
Terminal Emulation: ANSI VT100
Mode: 9600 Baud, 8-Data Bits 1-Start
Bit 1-Stop Bit, X ON - X OFF, No Parity
Connector: 9-Pin male IBM compatible
D-SUB connector
ENVIRONMENTAL
Operating Temperature Range: -40
to 65C
Environmental Protection: Conformal
coating for humidity and vibration
Contact factory for additional information

ORDERING INFORMATION
OUTPUTS

AUX. INPUTS

INPUT VOLTAGE

OFF TIME

PART NUMBER

10

4-20 mA Loop

DESCRIPTION

105 to 135 VAC

7 to 999 sec.

DNC-T2310-A10

10

4-20 mA Loop and 24 hr. clock

105 to 135 VAC

7 to 999 sec.

DNC-T2310-B10

10

4-20 mA Loop

210 to 270 VAC

7 to 999 sec.

DNC-T2310-A220

10

4-20 mA Loop and 24 hr. clock

210 to 270 VAC

7 to 999 sec.

DNC-T2310-B220

20

4-20 mA Loop

4*

105 to 135 VAC

7 to 999 sec.

DNC-T2320-A10

20

4-20 mA Loop and 24 hr. clock

2*

105 to 135 VAC

7 to 999 sec.

DNC-T2320-B10

20

4-20 mA Loop

4*

210 to 270 VAC

7 to 999 sec.

DNC-T2320-A220

20

4-20 mA Loop and 24 hr. clock

2*

210 to 270 VAC

7 to 999 sec.

DNC-T2320-B220

10

4-20 mA Loop in NEMA 4X box

105 to 135 VAC

7 to 999 sec.

DNC-T2310-KIT

20

4-20 mA Loop in NEMA 4X box

4*

105 to 135 VAC

7 to 999 sec.

DNC-T2320-KIT

ACCESSORY

DIMENSIONS

PART NUMBER

NEMA 4 Enclosure - Steel

10 x 8 x 4

BOX-A1008-CHNF

NEMA 4 Enclosure - Steel

12 x 10 x 5

BOX-A1210-CHNF

NEMA 4 Window Enclosure - Fiberglass


Pilot Lamp
ON/OFF Switch

12 x 10 x 6

BOX-A1210-CHSC

NEMA 4 Rated Red Light

ASL-00RED-NEMA-4

NEMA 4 Rated w Legend Plate

MSW-0DPST-001

* When unit is configured for expanded mode operation, input #4 is not available

AMETEK NCC offers NEMA 4 type enclosures for


mounting our controls. These enclosures are made of
heavy gauge steel or fiberglass and have a continuous hinge cover. All seams are continuously welded.
The finish is gray hammer-tone enamel inside and
out, over phosphatized surfaces for steel units,
smooth gray finish for fiberglass units.

4-17

DUST COLLECTOR CONTROLS

Model
DNC-T2310-A10

VACUUM FLUORESCENT
DISPLAY (8 CHAR.)
(16 SEGMENT)
6.875

POLYESTER OVERLAY
.25 DIA MOUNTING HOLE

KEYPAD

(4 PL.)

6.250

.312

RS-232 9 CIRCUIT
MALE CONNECTOR

2.275

2.5 MAX.

2 POS. SCREW TERMINAL


(3 PL.)

OUTPUT
STEP

.25

ITEM

VALUE

DIFFERENTIAL PRESSURE
CYCLE BYPASS INPUT

ALARM

D
DIFFERENTIAL PRESSURE ( P)
INCHES OF WATER

.65

CANCEL

RS232
CONNECTOR

National Controls
Corporation
1725 Western Dr.
West Chicago, IL. 60185

S/N:

BYPASS
INPUT

INTELLIGENT DUST CONTROL


MODEL NO.: DNC-T2310-010
INPUT VOLTAGE:120 VAC, 10VA

REMOTE ALARM
CONDITION OUTPUT

PRESSURE
CONNECTIONS:
HI SIDE

Date Code:

AUX ALARM
INPUTS

ALARM

ALARM

OUTPUT

ALARM VOLTAGE SOURCE

ALARM

LOW SIDE

8.75

INPUT

8.25

REMOTE ALARM
CONDITION INPUT

DO NOT USE SLOW-BLOW OR LARGER SIZE


FAILURE TO COMPLY WILL VOID ANY
WARRANTY

L1

L2

SOL
COM

5
6
OUTPUTS

USER HOOKUP
'HI' SIDE (DIRTY AIR PLENUM) AND
'LOW' SIDE (CLEAN AIR PLENUM )
PRESSURE CONNECTIONS
1/8-27" NPT FEMALE
FITTING CONNECTION
(2 PL.)

10

Model DNC-T2310-010

National Controls
Corporation

FUSE

L1

.06 THICK
ALUMINUM MOUNTING
PLATE

10 -OUTPUTS TO 120 VAC SOLENOID


AIR VALVES. SOL. COM. TERMINAL IS
INTERNALLY CONNECTED TO L2 TERMINAL.

L2

#6 SCREW TERM.
(13 PL.)

POLYESTER OVERLAY

Model
DNC-T2320-A10

DIFFERENTIAL PRESSURE
CYCLE BYPASS INPUT

RS-232 9 CIRCUIT
MALE CONNECTOR
SEE FIGURE 2

VACUUM FLUORESCENT
DISPLAY (8 CHAR.)
(16 SEGMENT)

REMOTE ALARM
CONDITION OUTPUT
(ALARM VOLTAGE
SOURCE)

4-20mA OUTPUT
ALARM

10.75
10.250

.25
2.325

REMOTE ALARM
CONDITION
INPUT

KEYPAD

2.5 MAX.

BYPASS 4-20mA ALARM


INPUT
OUTPUT
-

.59

.312

RS232

OUTPUT

2 POS. SCREW
TERMINAL (7 PL.)

ALARM
INPUT 1

STEP

ITEM

ALARM

VALUE
ALARM
CANCEL

DIFFERENTIAL PRESSURE (DP)


INCHES OF WATER

AUX
OUTPUT
#4

INTELLIGENT DUST CONTROL


MODEL NO.: DNC-T2320-B10
National Controls
INPUT VOLTAGE:120 VAC, 10VA
Corporation
1725 Western Dr.
Date Code:
West Chicago, IL. 60185 S/N:
PRESSURE
CONNECTIONS:
HI SIDE

.25 DIA. MOUNTING


HOLE (4 PL.)

AUX
INPUT
#4
120VAC

AUX OUTPUT FOR


EXPANDED MODE OR
AUX REMOTE ALARM
CONDITION OUTPUT
(ALARM VOLTAGE SOURCE)
L1
AUX INPUT
120 VAC
50/60 HZ ALARM OR
EXPANDED
L2

FOR
MODE

LOW SIDE

8.25

8.875

USER HOOKUP
HI SIDE ('DIRTY AIR PLENUM')
AND LOW SIDE ('CLEAN AIR PLENUM
PRESSURE CONNECTIONS
TAPPED 1/8-27 NPT
(2 PL.)
20
19
DO NOT USE SLOW-BLOW OR LARGER SIZE
FAILURE TO COMPLY WILL VOID AN Y WARRANTY

AUX ALARM
INPUTS

18
17

16
15
L1

FUSE

L2

SOL SOL
COM COM

10

11
12
OUTPUTS

13

14

#6 SCREW TERM.
(26 PL. )
.06 THICK
ALUMINUM
MOUNTING PLATE

L1
L2

20 -OUTPUTS TO 120 VAC SOLENOID AIR-VALVES


SOL. COM. TERMINALS ARE INTERNALLY CONNECTEDTO L2 TERMINAL