Sie sind auf Seite 1von 2

92-2533-01 Rev.

Installation Overview
Mounting Template

Applicator Interface Card Jumper and Connector Details

Loading
Left Hand Models

Right Hand Models

Direct Thermal Media

Host and Applicator Connections

15
14
13
15
14
J2 13

Remote Display
(Optional)

12
11

10
9
8
7
6

Serial Port A
Serial Port C
USB Port
Ethernet Port

Serial Port D
J4

GPIO Port B
Parallel Port

8
7
6

12

11

10

8
7
6
5

J1

Thermal Transfer Media with CSI Ribbon

3
2
1

1
1
J3

5
4

3
2
1

GPIO Port A

USB Host
(Optional)

SDIO Host
(Optional)

Note: Depending upon the model, features, options and configuration, this information will vary; consult the Operators Manual for detailed instructions.

Thermal Transfer Media with CSO Ribbon

GPI/O Port B Overview

GPI/O Port A Overview


Pin
1

Signal

Signal
Direction[1]

Ground

Jumper

Position

JMP 8
N/A

2
3

+5 VDC

Slew Label

Toggle /
Pause

Reprint

+24 VDC

Ground

10
11
12
13

Installed

Printer chassis is used.

Removed

Ground externally supplied.


Printer voltage used (.5 amp max)[4]

Removed

+5VDC externally supplied.


SOP signal; programmable

N/A

Printer chassis.
When inactive,
outputs pulled up to
a voltage determined
by jumper settings,
where:

Pins 1-2 = +5VDC;


Pins 2-3 = 24VDC;

Media Out

Data Ready

15

Option
Fault

Output

JMP 1

or,
None = Common
external voltage
(not to exceed
+30VDC) via
external pull-ups
(providing a 20K
ohm feedback thru
any two outputs).

Jumper

+5 VDC

JMP 11

Input 6

N/A

N/A

Input 3

N/A

N/A

Output 6

JMP 7

Programmable [1]; warning LOW


DIAMETER condition.
Evoked upon Fault
Programmable

[1]

[1]

; Active LOW.

; EOP process end.

Evoked when Out of Stock; active


LOW.
Evoked when Out of Ribbon; active
LOW.
Evoked if a label awaits; after the
SOP, printing begins. Active LOW.
Evoked during a Linear Scanner or
RFID fault; active LOW.

Position

Function / Description

Installed

Printer voltage used (.5 amp max)[4]

Removed

+5VDC externally supplied.


Programmed function.
Programmed function.

Installed: Pins 1-2

Programmed function pulled-up to +5VDC.

Installed: Pins 2-3

Programmed function pulled-up to +24VDC.

Removed

External source and pull-ups, not to exceed 30VDC.

Installed: Pins 1-2

Programmed function pulled-up to +5VDC.

Installed: Pins 2-3


Removed
Installed

Programmed function pulled-up to +24VDC.


External source and pull-ups, not to exceed +30VDC.
Printer chassis is used.

Output 3

JMP 4

Ground

JMP 10

Input 5

N/A

N/A

Programmed function.

Input 2

N/A

N/A

Programmed function.

Output 5

JMP 6

Installed: Pins 2-3

Pauses the printer when LOW.

Printer +24 VDC (1.5 amp maximum)

N/A

Service
Required
End Of
Print

14

N/A

Reprints the last label; and, if always


LOW, results in non-stop printing.

Ribbon Low

Ribbon Out

[3]

Advances media until HIGH and then,


if not Continuous, positions at TOF.
Input

Signal &
Direction [1]

Pin
1

Installed

Start Of
Print [2]

JMP 9

Function / Description

Removed

Installed: Pins 1-2


Removed

Ground externally supplied.

Programmed function pulled-up to +5VDC.


Programmed function pulled-up to +24VDC.
External source and pull-ups, not to exceed +30VDC.

Installed: Pins 1-2

Programmed function pulled-up to +5VDC.

N/A

Installed: Pins 2-3


Removed
N/A

Programmed function pulled-up to +24VDC.


External source and pull-ups, not to exceed +30VDC.
Printer +24 VDC (1.5 amp max).

N/A

N/A

Programmed function.

N/A

N/A

Programmed function.

10

Output 2

JMP 3

11

+24 VDC

12

Input 4

13

Input 1

Installed: Pins 1-2

Programmed function pulled-up to +5VDC.

14

Output 4

JMP 5

Installed: Pins 2-3

Programmed function pulled-up to +24VDC.

Removed
15

Output 1

[1]

JMP 2

External source and pull-ups, not to exceed +30VDC.

Installed: Pins 1-2

Programmed function pulled-up to +5VDC.

Installed: Pins 2-3

Programmed function pulled-up to +24VDC.

Removed

External source and pull-ups, not to exceed +30VDC.

Signal directions given relative to the printer.


If active with no current print job, WAITING FOR DATA will be displayed. Specifying a quantity of 9999 while keeping this signal ON will cause non-stop label printing, except in single label Imaging Mode which will cause the printer to stop between labels.
[3]
See PRINTER OPTIONS / GPIO PORT.
[4]
Drawing more than 0.5 amps can cause unreliable printer operation.
[2]

WARNING: Failure to properly configure the GPIO Port jumper settings may result in damage to the printer and / or applicator.

Das könnte Ihnen auch gefallen