c62925reafelp3.doc
November 5, 2001
Page
Clause/
Subclause
Paragraph
Figure/ Table
Type of Comment
Comment
Proposed change
(General/
Technical/Editorial)
General
Editorial
Editorial
Editorial
9
9
9
10
10
11
11
11
11
11
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.1
2.4
Reference [1]
Reference [2]
Reference [4]
Reference [7]
Reference [8]
Reference [24]
Reference [25]
Reference [26]
Reference [27]
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
14
4.1
2nd , last
sentence
Editorial
14
4.2.1
14
4.2.1
General
Line 1
Coordination
IEEE 76CH1066-0-PWR
IEEE Seminar/Report 87TH0176-8-PWR
IEEE Std 18-1992
IEEE Std 824-1994
IEEE Std 1036-1992
IEEE Std. C37.99-1990
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Replace with Std 1313.1 and/or 1313.2.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Replace with the standard.
Ref. 24; the IEEE std C37.04 have been revised and Change date: [24] IEEE std C37.04-1999, IEEE
the actual version is 1999.
standard rating. (withdraw: 1979 (reaff 1988))
A couple of commas seem to be missing.
Add a comma between voltage and possibly and also
between generator and out.
Some modifications to the text needs to be
None given.
considered here to acknowledge changes to the
selection and application of metal oxide surge
arresters as evident in the revised IEEE Guide for
the Application of Metal-Oxide Arresters for
Alternating-Current Systems - C62.22-1997.
I am a member of IEEE 1159 Recommended
In this case Table 2 indicated Voltage Swell. The
Practice for Monitoring Electric Power Quality. The duration of the event determines the categories.
term Temporary Overvoltage may not apply
Voltage Swell has Instantaneous, Momentary, and
according to Table 2. Overvoltages are greater than Temporary. Instantaneous is .5 to 30 cycles.
one minute.
Momentary is 30 cycles to 3 seconds. Temporary is 3
seconds to one minute. Over one minute is an
Page 1 of 4
Page
Clause/
Subclause
Paragraph
Figure/ Table
Type of Comment
15
4.2.2
1st , line 12
Editorial
15
15
4.2.2
4.3
1st , line 7
Editorial
Editorial
18
20
20
20
20
20
20
4.4
4.3
5.1
5.1
5.2.1
5.2.1
5.2.2
Heading
Line 8
1st , line 4
3rd , line 2
21
21
5.2.2
5.2.2
2nd line 3
2nd line 3
21
5.3
23
25
5.4
6
1st , line 3
1st , line 1
Editorial
Editorial
26
26
7.1
7.1.3
Last line
2nd
Editorial
Editorial
26
29
29
29
29
29
31
7.1.3
9
9
9
9
9
Annex A
2nd line 8
[B1]
[B2]
[B3]
[B4]
[B5]
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Line 4
Comment
Proposed change
(General/
Technical/Editorial)
Editorial
Coordination
Editorial
Editorial
Editorial
Editorial
General
Editorial
Editorial
General
overvoltage condition.
Remove the (.
Add parenthesis.
Consider changing diagram with a neutral reactor is
shown for an autotransformer with a to diagram is
shown for an autotransformer with a neutral reactor
and with a.
Grounding Relaying may not be the correct term.
Consider changing to Ground Relaying.
In the related figure B2
Does that need to be 2a rather than B2
There is an extra set of ( ).
Change ([1]) to [1].
There is an extra set of ( ).
Change ([1]) to [1].
"maximu" in first sentence should be 'maximum"
Add m.
Standard has been revised and updated.
Update the date.
Restrikes and reignitions, as I recall, are not
It would be a good idea to check the definitions in one
considered to be the same phenomena in relation to of the circuit breaker standards e.g. C37--.
what happens in a circuit breaker. The former refers
to thermal breakdown, while the latter and more
serious condition with respect to generating
overvoltages, refers to dielectric breakdowns.
Interruped is not the correct word
Consider changing interruped to interrupting
Wording in sentence does not seem to be correct.
Consider changing end of sentence to in a circuit
breaker when a line to ground fault was interrupted.
I would submit that the use of the term "restrike-free" None given.
in regard to circuit breakers demands some
qualification, or should be avoided. Oil circuit
breakers are certainly not restrike-free, and there
may be questions about the capabilities of vacuum
breakers, especially when switching shunt capacitor
banks.
There is an extra set of ( ).
Change ([1]) to [1].
The word standard seems to be missing.
Consider changing grounding (IEEE Std C62.92.2
[B2]) contains to grounding standard [B2] contains.
Is 230 kV the correct number?
Consider a lower voltage rating if appropriate.
This paragraph may not be completely correct.
Check paragraph for total correctness of the triple
harmonics.
No reference is given for inductive coordination.
Consider adding a reference to C62.92.4
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Standard has been revised and updated.
Update the date.
Title should have "or" instead of "of".
Change "of" to "or" in title.
Page 2 of 4
Page
Clause/
Subclause
31
31
A.1
A.1.1
31
A.1.1
31
A.1.1
32
A1.4
33
A.2
34
34
34
A.3
A.3
A.3
34
A.3
34
A.3
35
35
A.4
A.4
35
35
A.4
A.4
35
A.4
35
A.4
35
A.4
36
A.5
37
Annex B
38
Annex B
Paragraph
Figure/ Table
Type of Comment
Comment
Proposed change
(General/
Technical/Editorial)
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Editorial
Equation is incorrect.
Equation is incorrect.
Item (4) reference IEE Std. 32. Missing "E".
Editorial
Editorial
Editorial
Editorial
Equation is incorrect.
Standard has been revised and updated.
Editorial
Editorial
Equation is incorrect.
Standard has been revised and updated.
Editorial
Editorial
Editorial
Editorial
Eq. B1 &
Eq. B4
Eq. B9,
Eq. B10, and
Eq. B11
Editorial
Technical
Page 3 of 4
Page
38
Clause/
Subclause
Annex B
Paragraph
Figure/ Table
Eq B11
Type of Comment
Comment
Proposed change
(General/
Technical/Editorial)
Editorial
FORM 8C (IEC)
1998-03-01
Page 4 of 4