Sie sind auf Seite 1von 182

About TE Connectivity

TE Energy innovative and economical solutions for the electrical power industry: cable accessories, connectors &
fittings, insulators & insulation, surge arresters, switching equipment, street lighting, power measurement and control.

Tyco Electronics UK Ltd


TE Energy
Freebournes Road
Witham, Essex CM8 3AH
Phone: +44 (0)870 870 7500
Fax: +44 (0)870 240 5289
Email: dormansmithswitchgear@te.com
E-fax: +44 (0)1793 602431
www.dormansmithswitchgear.com
www.energy.te.com

Tyco Electronics UK Ltd DS-EPP-CAT-06/11

While TE Connectivity (TE) has made every reasonable effort to ensure the accuracy of the information in this catalog, TE does not guarantee that it is error-free, nor does TE make any
other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein
at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability
or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without
notice. Consult TE for the latest dimensions and design specifications. Dorman Smith three line logo, Integra, Loadline, TE connectivity (logo) and TE Connectivity are trademarks of the TE
Connectivity Ltd. family of companies. Crompton is a trademark of Crompton Parkinson and is used by TE Connectivity Ltd. under a licence. Other logos, product and Company names
mentioned herein may be trademarks of their respective owners.

Dorman Smith Switchgear Product Portfolio

TE Connectivity is a global, $12.1 billion company that designs and manufactures


over 500,000 products that connect and protect the flow of power and data inside
the products that touch every aspect of our lives. Our nearly 100,000 employees
partner with customers in virtually every industry from consumer electronics,
energy and healthcare, to automotive, aerospace and communication networks
enabling smarter, faster, better technologies to connect products to possibilities.

Dorman Smith Switchgear


Product Portfolio

How to use this catalogue


This catalogue has been designed to enable users to access the information on the
whole product range in a straight-forward and logical manner. We are conscious
that the needs of our customers vary considerably and that, as our markets
continue to grow, many will be dealing with our systems and products for the
first time.
Where product codes are already well known, the Product and Parts Locator at the
back of the catalogue will direct you to the pages relevant to each occurrence of a
particular item.
Each main product or system category has its own section. The sections are
arranged such that those detailing the simpler and smaller systems are at the
beginning. Exploded views of typical system configurations are given as a guide,
near to the front of each section.
In order to help you to build a system, there are detailed Selection Charts at the
end of each section. Again, these are formatted in a logical manner, from main
housings to incomers, outgoing devices to their accessories. Once a reasonable
level of familiarity with the TE Connectivity Dorman Smith product range has been
attained, complete circuit distribution systems can be readily configured directly
from the Selection Charts alone.
Following the main products sections, the Technical Data and Applications section
provides a high level of detail on both specific products and the principles of circuit
protection in general.
We trust you will find this catalogue informative, helpful and a quick and easy-touse tool whenever you need to configure MCB or MCCB distribution schemes.

YA5ML
YA5MMS
YA5MW10
YA5MW15
YA5N3P250T
YA5N3P400T
YA5N4P250T
YA5N4P400T
YA5NL
YA5PB3P
YA5PB4P
YA5PRA3P
YA5PRA4P
YA5PT3P
YA5PT4P
YA5PXT3P
YA5PXT4P
YA5R1
YA5R2
YA5RT3P
YA5RT4P
YA5TB
YA5TC3P
YA5TC4P
YA5TS3P
YA5TS4P
YA5XT3P
YA5XT4P
YAA1PLB
YAA3PLB
YAA3PLFT2
YAAL
YAAUX1
YADL1
YAST115AC
YAST240AC
YAST24DC
YAST450AC
YAUVR120AC
YAUVR240AC
YAUVR24DC
YAUVR450AC
YB1N1P100T
YB1N1P125T
YB1N1P16T
YB1N1P20T
YB1N1P25T
YB1N1P32T
YB1N1P40T
YB1N1P50T
YB1N1P63T
YB1N1P80T
YB1N3P100T
YB1N3P125T
YB1N3P160T
YB1N3P25T
YB1N3P32T
YB1N3P40T
YB1N3P63T
YB1N3P80T

108
108
108
108
39, 62, 107
39, 62, 107
39, 107
39, 107
108
108
108
108
108
108
108
108
108
108
108
108
108
108
66, 108
108
39, 41, 62, 108
39, 41, 62, 108
108
108
106
106
106
104
104
41, 62, 106, 107
41, 62, 104
41, 62, 104
41, 62, 104
41, 62, 104
41, 62, 104
41, 62, 104
41, 62, 104
41, 62
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102

YB1N4P100T
YB1N4P125T
YB1N4P160T
YB1N4P25T
YB1N4P32T
YB1N4P40T
YB1N4P63T
YB1N4P80T
YB3B3P250D
YB3B4P250D
YB3N3P100T
YB3N3P125T
YB3N3P160T
YB3N3P200T
YB3N3P250T
YB3N3P50T
YB3N3P63T
YB3N4P100T
YB3N4P125T
YB3N4P160T
YB3N4P200T
YB3N4P250T
YB3N4P50T
YB3N4P63T

102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102
102

181

Electrical Distribution and Circuit


Protection Product Catalogue
How to use this catalogue
Contents

TE Connectivity/Dorman Smith

Contents
SP&N Distribution Systems (A-type)

5-14

TP&N Distribution Systems (B-type)

15-34

MCCB Panel Boards (250A & 400A)

35-44

Fuse Switch Panel Boards (800A)

45-56

MCCB Panel Boards (400A & 800A)

57-80

Fuse Combination Units

81-92

Dorman Smith Circuit Protection and


Modular Devices

93-128

MCB and MCCB General Purpose Enclosures

129-130

Technical Data & Applications

131-174

Products & Parts Locator

175-184

1
2
3
4
5
6
7
8
9
10
10

L
4
LM 50
20 1
LM 60 20
10
LM 2P 10
24
LM 3P 20
112
LM 3P 30
24
2
LM 3P 40
11
LM 3P 2
24
2
LM MB 3
1
1
M
B
4
M

110
110
110

11
26

Solutions for Current Regulations


TE Connectivity provides solutions for easy compliance of current regulations within electrical installations
by utilising products from both the Dorman Smith and Crompton Instruments brand portfolios.
Enhancing the design of Dorman Smith products to incorporate metering and surge protection facilities
has made it easy and more economical to comply with the necessary regulations.

Easy Compliance
17th Edition IEE Wiring Regulations
Part L2 Building Regulations

To find out more, please contact our sales team


Tel: +44 (0) 870 870 7500 Fax: +44 (0) 870 240 5289
Email: electrical@te.com, www.dormansmithswitchgear.com
TE connectivity (logo), TE Connectivity and Dorman Smith are trademarks.
Crompton is a trademark of Crompton Parkinson Ltd., and is used by TE Connectivity under licence.

Protection Against Lightning Electrical and


Electronic Systems with Structures BS EN 62305-4

TE Connectivity
With a 50-plus year history of leadership, TE Connectivity is a global, $12.1
billion company that designs and manufactures over 500,000 products
that connect and protect the flow of power and data inside the products
that touch every aspect of peoples lives. Our nearly 100,000 employees
partner with customers in virtually every industry from consumer
electronics, energy and healthcare, to automotive, aerospace and
communication networks enabling smarter, faster, better technologies to
connect products to possibilities.
TE Energy connecting the world of power
TE Energy, a global operating unit within TE Connectivity, is focused on providing
products and systems for the electrical power industry. TE Energy products are
extensively used by power utilities, equipment manufacturers, railways and by a
wide range of industries.
Each Business Unit within the TE Energy comes with a specialised product line and
focused set of application skills for its specific market niche. Thus TE Energy is able to
bring innovative and technology driven products efficiently to market by
synchronising the product development and manufacturing facility capabilities.
TE Energy is a global supplier of:
Cable accessories
Connectors and fittings
Insulators and insulation
Surge arresters
Switching, protection and lighting
Power measurement and control

Dorman Smith Switchgear


Dorman Smith Switchgear has been a part of TE Connectivity since 2000.
With over 130 years of experience in switchgear design and production,
Dorman Smith business unit continues to bring high quality electrical
distribution and circuit protection equipment to market.
Dorman Smith business unit's line-up of electrical equipment begins with simple
SP&N distribution boards and extends to custom designed, factory built, lowvoltage switchboards for a broad range of commercial and industrial applications.
Dorman Smith and Crompton Instruments products combine through shared
technologies and close co-operation a complementary portfolio of low voltage
power measurement and protection products for energy applications worldwide.
The extensive array of electrical distribution systems suited to a broad scope of ,
commercial and industrial applications, together with instruments for measurement
of key electrical parameters ensures unrivalled capability to fulfil the most
demanding specifications.
End user applications for the companys products and systems are found in rail
transportation, building management, utilities and infrastructure, together with
the manufacturing sector and many parts of the process industry.
The Dorman Smith product range includes:
MCB distribution board systems
MCCB panel board systems
Fuse combination switch units
Modular control devices
Digital metering panel instruments

Dorman Smith Modis Switchboards


The range of Modis LV distribution switchboard systems is designed and engineered by Dorman Smith business unit
and this range of fully type tested assemblies comprehensively covers all low-voltage switchboard requirements up to
3200 amps!
The Modis range of LV distribution switchboard systems is available as wall-mounted or floor standing with front or
rear access.
Assembled by our trained certified partners, the Modis range of LV distribution switchboards is more than capable of
satisfying individual customer needs, for the control and protection of the power distribution system in commercial
and industrial applications.

To find out more, please contact our sales team


Tel: 01772 325 380 Fax: 01772 325 385
Email: electrical@te.com, www.dormansmithswitchgear.com
TE connectivity (logo), TE Connectivity, Dorman Smith and Modis are trademarks.

Section

SP&N Distribution Systems


Loadlimiter 63 Range of SP&N Distribution
Systems (A-type)

Overview
Key Features
Distribution board has 125A
rated busbars
Distribution boards can
be stacked
Choice of switch disconnector
or RCCB incomer
Boards have standard height
(250mm) and depth (116mm)

The Dorman Smith Loadlimiter 63 distribution system


includes a versatile range of MCB distribution boards
and components for constructing comprehensive SP&N
circuit management solutions. The system is designed
for applications demanding up to 125A incoming and
63A outgoing capacity and the distribution board
exceeds the requirements of EN 60439-3.

Available Options
Distribution boards provide from
6 to 22 outgoing ways
Incomer can be double-pole
switch disconnector up to 125A
or double-pole RCCB up to 100A
Outgoing ways can be
configured with 10kA-rated
MCBs or RCBOs
Matching service centres
equipped with 8 to 24
modular ways

Additional Features
Single module shunt trip
and auxiliary contacts easily
fitted to MCBs
Neutral and earth terminal for
each single-pole way
IP4X Ingress Protection

Compliance
Distribution boards EN 60439-3
MCBs
EN 60898
Contactors
EN 61095
RCBOs
EN 61009
RCCBs
EN 61008

The array of circuit devices includes an extensive range


of MCBs, RCBOs, RCCBs and switch disconnectors.
The system ensures simple configuration and quick
installation as demanded by todays new and retrofit,
commercial and industrial applications.
The standard finish is epoxy powder coating in light
grey RAL 7035.

SP&N Distribution System

A-type Distribution Boards


Service centres
Stacking kits

Incoming Devices
Switch disconnectors
Residual current circuit
breakers - RCCB

Circuit Protection Devices


Miniature circuit breakers
Residual current circuit breaker with
overcurrent protection - RCBO
Residual current circuit breakers - RCCB

Modular Devices

Surge protection
Metering
Contactors
Timer
Residual current circuit breaker

Loadlimiter 63
A-type Distribution Boards and Accessories
A-type Distribution Boards

Exceeds the requirements of EN 60439-1


125A rated
Neutral and earth terminal for each single-pole way
6-22 single-pole outgoing ways
IP4X Ingress Protection
Outgoing
1-pole ways

Width
(mm)

Weight
(kg)

Cat. no.

6
9
12
15
18
22

270
323
377
430
484
555

3.8
4.3
4.8
5.3
6.0
7.0

DA06X
DA09X
DA12X
DA15X
DA18X
DA22X

A-type Service Centre


Accepts all DIN-rail mounting devices
8-24 modular ways
IP4X Ingress Protection

Modular ways

Width (mm)

Weight (kg)

Cat. no.

8
11
14
17
20
24

270
323
377
430
484
555

3.8
4.3
4.8
5.3
6.0
7.0

DAS08X
DAS11X
DAS14X
DAS17X
DAS20X
DAS24X

Accessories for A-type Distribution Boards


Description

Vertical stacking kits


Stacking kit for 270mm width
Stacking kit for 323mm width
Stacking kit for 377mm width
Stacking kit for 430mm width
Stacking kit for 484mm width
Stacking kit for 555mm width
Earth bar kits
Earth bar
Earth bar isolation kit
Door lock kits
Cylinder door lock
Padlock bracket kit
Blanking kits
10 busbar terminal blanks
MCB blanks
4xTP MCB + 12 busbar terminal blanks
5x1P MCB + 5 busbar terminal blanks
1
5x 2 MCB blanks

Picture

Cat. no.

1
1
1
1
1
1

DAXSK08
DAXSK11
DAXSK14
DAXSK17
DAXSK20
DAXSK24

3
3

DAXEB
DBXL

4
4

DBXCL
DBXPL

DAXTP

5
6
-

DBXBP
DBXBM
DBXBH

Loadlimiter 63
A-type Distribution Boards Incoming Options
Switch Disconnector
Exceeds the requirements of EN 60947-3
50mm2 cable capacity
Duty category of AC22

Incoming
device type

Current
rating (A)

Poles

Max. cable
(mm2)

Cat. no.

Switch disconnector
Switch disconnector

100
125

2
2

50
50

AV2100
AV2125

Double-pole RCCB

Exceeds the requirements of EN 61008


Equipped with transient suppression filter
Voltage 230/400V 50/60 Hz
Double module for both type AC
Terminal capacity: top 25mm2
Terminal capacity: bottom 35mm2

Incoming
device type

Current
rating (A)

Sensitivity
(mA)

Device
type

Cat. no.

RCCB
RCCB
RCCB
RCCB
RCCB
RCCB
RCCB time delay

63
63
63
80
100
100
100

30
100
300
30
30
100
100

AC
AC
AC
AC
AC
AC
AC

EE63/30/2
EE63/100/2
EE63/300/2
EE80/30/2
EE100/30/2
EE100/100/2
EES100/100/2

Direct Connection
1
Incoming device type

Max. cable (mm2)

Pic number

Cat. no.

Direct connection
Direct connection

35
70

1
2

DBXD0
DAXD1

Surge Protection

Plug-in surge protection modules


Integral protection status indicator
Operating range 200-300V rms max
Hot working replaceable modules
Terminals 35mm2 max

See page 116 for more information.


Device type

Cat. no.

SP + NE surge protection
MOV replacement plug-in module
MOV neutral/earth replacement plug-in module

DSPM1PN
DSPML
DSPMNE

Note: It is recommended that SPM surge protectors are installed on the load
side of a MCB - type C, MCCB or a fused disconnector 63A to provide isolation
and protection.

Loadlimiter 63
A-type Outgoing Devices
Single-pole MCBs

Exceeds the requirements of EN 60898


10kA rated breaking capacity to EN 60898
15kA rated breaking capacity to EN60947-2
Contact position indicator
35mm2 cable capacity

Current rating (A)

B type cat. no.

C type cat. no.

D type cat. no.

6
10
13
16
20
25
32
40
50
63

K1PB06
K1PB10
K1PB13
K1PB16
K1PB20
K1PB25
K1PB32
K1PB40
K1PB50
K1PB63

K1PC06
K1PC10
K1PC13
K1PC16
K1PC20
K1PC25
K1PC32
K1PC40
K1PC50
K1PC63

K1PD06
K1PD10
K1PD16
K1PD20
K1PD25
K1PD32
T1PD40*
T1PD50*
T1PD63*

* 6kA/10kA - EN60898/EN60947-2

Single Module RCBOs

Exceeds the requirements of EN 61009


Single module: type AC
10kA rated breaking capacity
Terminal capacity: top terminals 10mm2
Terminal capacity: bottom terminals 35mm2

Current rating (A)

Sensitivity (mA)

B type cat. no.

C type cat. no.

6
10
16
20
32
40
45
6
10
16
20
32
40

30
30
30
30
30
30
30
100
100
100
100
100
100

KR1PB0630
KR1PB1030
KR1PB1630
KR1PB2030
KR1PB3230
KR1PB4030
KR1PB4530
-

KR1PC0630
KR1PC1030
KR1PC1630
KR1PC2030
KR1PC3230
KR1PC4030
KR1PC4530
KR1PC06100
KR1PC10100
KR1PC16100
KR1PC20100
KR1PC32100
KR1PC40100

Double Module RCBOs


Exceeds the requirements of
EN 61009, IEC 61009
SP&SwN configuration
Rated breaking capacity up to 10kA
Contact position indicator
Rated voltage Ue ~230V
Rated frequency 50Hz

10

Energy limiting class 3


Type AC
Terminal capacity: outgoing
terminals 35mm2
Terminal capacity: busbar side
terminals 35mm2

Current rating (A)

Sensitivity (mA)

B type cat. no.

C type cat. no.

6
10
16
20
32
40

30
30
30
30
30
30

KR2PB0630
KR2PB1030
KR2PB1630
KR2PB2030
KR2PB3230
KR2PB4030

KR2PC0630
KR2PC1030
KR2PC1630
KR2PC2030
KR2PC3230
KR2PC4030

Loadlimiter 63
A-type Metering and Accessories
Accessories for MCBs and RCBOs
Auxiliary equipment

Picture

Cat. no.

MCB shunt trip (240V AC)


MCB auxiliary/switching contact

KST240
KAUX1

Padlocking

Picture

Cat. no.

MCB dolly locking device


Padlock for dolly locking device

KDL
XPL

DIN-rail Mounted Meters


DIN-rail mountable in Loadlimiter 63 service centres

Device type

Outputs

Width
(mm)

Cat. no.

3-phase analogue
kWh meter

1 pulse

71

DRK-3PCT-415

3-phase digital kWh meter

1 pulse

71

DRK-3PCT-415-LCD

1-phase/3-phase digital
multi-function meter

1 pulse &
1 modbus

71

RI3-01

1-phase digital kWh meter


with integral 63A
current transformer

1 pulse

54

DRK-1P-230-D63

Measuring Current Transformers


System voltage up to 720V
Secondary output of 5A
Operating temperature range of 20C to +70C

Width
(mm)

Cat. no.

65

45

M53Q-100/5

25

65

45

M53Q-125/5

M30-DINCLIP

Description

Cable aperture Height


(mm)
(mm)

100A current transformer

25

125A current transformer


DIN-rail clip

11

Loadlimiter 63 Selection Chart - A-type


Distribution Boards
Busbar rating

Outgoing ways

Width (mm)

Weight (kg)

Cat. no.

125A
125A
125A
125A
125A
125A

6
9
12
15
18
22

270
323
377
430
484
555

3.8
4.3
4.8
5.3
6.0
7.0

DA06X
DA09X
DA12X
DA15X
DA18X
DA22X

Service Centres
For DIN-rail modules

Modular ways

Service
Service
Service
Service
Service
Service

8
11
14
17
20
24

270
323
377
430
484
555

3.8
4.3
4.8
5.3
6.0
7.0

DAS08X
DAS11X
DAS14X
DAS17X
DAS20X
DAS24X

centre
centre
centre
centre
centre
centre

Incoming Devices
Device type

Current rating (A) Sensitivity (mA)

Max. cable (mm2)

Switch disconnector
Switch disconnector
RCCB, type AC
RCCB, type AC
RCCB, type AC
RCCB, type AC
RCCB, type AC
RCCB, type AC
RCCB type AC time delay
Direct connection
Direct connection

100
125
63
63
63
80
100
100
100
-

50
50
35
35
35
35
35
35
35
35
70

30
100
300
30
30
100
100
-

AV2100
AV2125
EE63/30/2
EE63/100/2
EE63/300/2
EE80/30/2
EE100/30/2
EE100/100/2
EES100/100/2
DBXD0
DAXD1

Surge Protection
SP + NE surge protection
MOV replacement plug-in module
MOV neutral/earth replacement plug-in module

DSPM1PN
DSPML
DSPMNE

Accessories for DA Type Distribution Boards


Vertical stacking kits
Stacking kit for 270mm width
Stacking kit for 323mm width
Stacking kit for 377mm width
Stacking kit for 430mm width
Stacking kit for 484mm width
Stacking kit for 555mm width
Blanking kits
Busbar terminal blanks (set of 10)
Earth bar kits
Earth bar
Earth bar isolation kit
Door lock kits
Cylinder door lock
Padlock bracket kit

12

DAXSK08
DAXSK11
DAXSK14
DAXSK17
DAXSK20
DAXSK24
DAXTP
DAXEB
DBXL
DBXCL
DBXPL

Loadlimiter 63 Selection Chart - A-type


SP&N MCBs B, C & D types
10kA/15kA breaking capacity

Current rating (A)

B type cat. no.

C type cat. no.

D type cat. no.

1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole

6
10
13
16
20
25
32
40
50
63

K1PB06
K1PB10
K1PB13
K1PB16
K1PB20
K1PB25
K1PB32
K1PB40
K1PB50
K1PB63

K1PC06
K1PC10
K1PC13
K1PC16
K1PC20
K1PC25
K1PC32
K1PC40
K1PC50
K1PC63

K1PD06
K1PD10
K1PD13
K1PD16
K1PD20
K1PD25
K1PD32
T1PD40*
T1PD50*
T1PD63*

SP&N RCBOs B & C types


10kA breaking capacity
Device type

Current rating (A)

Sensitivity
(mA)

B type
cat. no.

C type
cat. no.

Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single

6
10
16
20
32
40
45
6
10
16
20
32
40

30
30
30
30
30
30
30
100
100
100
100
100
100

KR1PB0630
KR1PB1030
KR1PB1630
KR1PB2030
KR1PB3230
KR1PB4030
KR1PB4530
-

KR1PC0630
KR1PC1030
KR1PC1630
KR1PC2030
KR1PC3230
KR1PC4030
KR1PC4530
KR1PC06100
KR1PC10100
KR1PC16100
KR1PC20100
KR1PC32100
KR1PC40100

6kA/10kA - EN60898/EN60947-2

module,
module,
module,
module,
module,
module,
module,
module,
module,
module,
module,
module,
module,

type
type
type
type
type
type
type
type
type
type
type
type
type

AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC
AC

Accessories for MCBs and RCBOs


Description

Cat. no.

Auxiliary equipment
MCB shunt trip (240V ac)
MCB auxiliary/switching contact

KST240
KAUX1

Padlocking
MCB dolly locking device
Padlock for dolly locking device

KDL
XPL

Blanking pieces
MCB blanks (4xTP MCB ways + 12 busbar terminal blanks)
MCB blanks (5xSP MCB ways + 5 busbar terminal blanks)
1
MCB blanks (5x 2 MCB ways)

DBXBP
DBXBM
DBXBH

Metering
Description
3-phase analogue kWh meter
3-phase digital kWh meter
1-phase/3-phase digital multi-function meter
1-phase digital kWh meter with integral 63A
current transformer
Current transformer, 100A
Current transformer, 125A

Outputs

Width (mm)

Cat. no.

1 pulse
1 pulse
1 pulse & 1 modbus

71
71
71

DRK-3PCT-415
DRK-3PCT-415-LCD
RI3-01

1 pulse
-

54
-

DRK-1P-230-D63
M53Q-100/5
M53Q-125/5

13

Loadlimiter 63
Outline Drawings and Dimensions
A-type Distribution Boards
1-pole ways

Width (mm)

Weight (kg)

Cat. no.

6
9
12
15
18
22

270
323
377
430
484
555

3.8
4.3
4.8
5.3
6.0
7.0

DA06X
DA09X
DA12X
DA15X
DA18X
DA22X

A-type Service Centres


All dimensions in mm

14

Modular ways

Width (mm)

Weight (kg)

Cat. no.

8
11
14
17
20
24

270
323
377
430
484
555

3.8
4.3
4.8
5.3
6.0
7.0

DAS08X
DAS11X
DAS14X
DAS17X
DAS20X
DAS24X

Section

TP&N Distribution Systems


Loadlimiter 63 Range of TP&N Distribution
Systems (B-type)

Overview
Key Features
Conforms to EN 60439-3
ASTA certified busbars rated at
10kA for 250ms
Neutral and earth terminal
25mm2 for each single-pole way
Clean earth facility
Enclosures are 484mm wide x
159 deep
4 to 24 TP&N outgoing ways
IP4X Ingress Protection
Double earth kits available
Extended service centres with
fitted earth and neutral terminals

Available Options
Incomer can be switch
disconnector, contactor, fuse
switch, MCCB or RCCB
Outgoing ways can be
configured with 10/15kA-rated
MCBs or RCBOs
Matching service centres
equipped with one or two rows
of 18-pole ways
Surge protection modules can
be accommodated within
standard configuration
Modular DIN-rail meter fits
within standard configuration

Benefits
Extra spreading room for single
module RCBOs
Multi incoming options
Earth/neutral close to phase
terminal
MCBs with symmetrical dual
terminals
Integral metering options
Exceptional flexibility

Applications
Commercial and industrial final
circuit protection
Part L2 building regulations
17th edition wiring regulations

Compliance
Distribution boards EN60439-3
MCBs
EN60898
Contactors
EN61095
RCBOs
EN61009
RCCBs
EN61008

16

The Dorman Smith Loadlimiter 63 TP&N distribution


board system excels in providing flexible and cost
effective final circuit management solutions for
commercial and industrial applications.
Featuring a comprehensive range of TP&N distribution
boards rated at 250A and a wide array of circuit
devices the system ensures simple configuration as well
as quick assembly for new and retrofit applications.
To suit current industry regulation requirements the
range has been extended to offer a vast collection of
metering accessories including fully assembled metered
power and lighting distribution boards. This range
consists of both stocked and customised options
providing an easy and flexible solution to comply with
Part L2 Building Regulations and specification
requirements.
The standard finish is epoxy powder coating in light
grey RAL 7035.

TP&N Distribution System

B-type Distribution Boards

Service centres
Stacking kits
Assembled metered boards
Metering enclosures

Incoming Devices

Switch disconnectors - modular 125A max


Switch disconnectors - MCCB 250A max
Residual current circuit breakers - RCCB
Fuse switch
Moulded case circuit breakers
Contactors

Circuit Protection Devices


Miniature circuit breakers
Residual current circuit breaker with
overcurrent protection - RCBO
Residual current circuit breaker - RCCB

Modular Devices
Surge protection
Meters, current transformers and
wiring looms
Contactors
Timer
Residual current circuit breaker

17

Loadlimiter 63
B-type Distribution Boards and Enclosures
B-type Distribution Boards

Exceeds the requirements of EN 60439-3


ASTA certified busbars rated at 10kA for 250mS
Neutral and earth terminal 25mm2 for each single-pole way
Integral clean earth facility
Enclosure are 484mm wide x 159mm deep
4-24 TP&N outgoing ways
IP4X Ingress Protection

Outgoing
3-pole ways

Height
(mm)

Weight
(kg)

Cat. no.

4
6
8
12
16
20
24

544
598
651
758
865
1025
1132

10
11
12
15
18
22
27

DBX04R
DBX06R
DBX08R
DBX12R
DBX16R
DBX20R
DBX24R

Double earth bar kits are available


Order as DBTE**X, where ** = 04 to 24.

250A Incoming Housing


Enclosure to mount any YA3 Frame MCCB up to 250A
Facility to mount two panel mounted meters (using available knockouts)

Incomer

Height (mm)

Weight (kg)

Cat. no.

3-pole unit
4-pole unit

321
321

8
8

DBXYA3
DBXYA3

Note: Devices to be ordered separately.


Triple-pole device requires neutral link YA3NL to be ordered separately.

Description

Cat. no.

YA3 neutral link

YA3NL

Service Centres for all B-type Distribution Boards

Accepts all DIN-rail mounting devices


18 or 36 modular ways
IP4X Ingress Protection
General purpose enclosure includes facility to mount two panel mounted meters
and DIN-rail for current transformers
Neutral and earth bars fitted as standard

Modular ways
18 x 1-pole ways
(single row)
36 x 1-pole ways
(double row)
General purpose
enclosure

Height (mm)

Weight (kg)

Cat. no.

213

DBS18X

427

DBS36X

213

DBMSB

Supplied without top or bottom plate. Intended for use with removable plate from
distribution board.

18

Loadlimiter 63
B-type Distribution Boards Accessories
Description
Conversion kits plus spares
TP&N to SP&N conversion kit
Spare end plate
Fixing kit for 24 way distribution boards
Blank way label for 24 way distribution boards
DA18X to B type board stacking kit
Blanking pieces
MCB blanks (4xTP MCB ways + 12 busbar terminal blanks)
MCB blanks (5x1P MCB ways + 5 busbar terminal blanks)
MCB blanks (5x12 MCB Ways)
Joining kit
Kit for vertically joining two distribution boards
Terminal bars
Terminal bar for 6 ways (6 useable 1P ways)
Terminal bar for 12 ways (12 useable 1P ways)
Terminal bar for 18 ways (18 useable 1P ways)
Terminal bar for 24 ways (24 useable 1P ways)
Blanking kits
Busbar terminal blanks (set of 10)
Earth bar kits
Earth bar
Earth bar isolation kit
Double earth bar facility
Earth bar kit with terminal for each outgoing way
(where ** = 04, 06, 08, 12, 16, 20 or 24 ways)
Door lock kits
Cylinder door lock
Padlock bracket kit

Picture

Cat. no.

1
2

DBXTS
DBXEP
DBX24FK
DBX24WL
DBXSKA

3
5

8
9

DBXBP
DBXBM
DBXBH

DBXJK

7
6
6
6
6

DBXT06
DBXT12
DBXT18
DBXT24

DAXTP

7
5

DAXEB
DBXL

10
DBTE**X
10
11

DBXCL
DBXPL

11

19

Loadlimiter 63
B-type Incoming Options
Switch Disconnector 125A Max
Exceeds the requirements of EN 60947-3
50mm2 cable capacity
Duty category of AC22

Switch disconnector
Device type

Max. cable
(mm2)

100A, 3-pole
100A, 4-pole

50
50

125A, 3-pole
125A, 4-pole

50
50

Sensitivity
(mA)

Incoming
device cat. no.

Connection
kit cat. no.

AV3100
AV4100

N/A
DBXCKR

AV3125
AV4125

N/A
DBXCKR

RCCBs
Exceeds the requirements of EN 61008
Double width module, 35mm
Type AC
Terminal capacity: 40A-63A: 25mm2
Terminal capacity: 100A: 35mm2

4-pole RCCB
40A, type AC
40A, type AC
63A, type AC
63A, type AC
63A, type AC
100A, type AC
100A, type AC
100A, type AC
100A, type AC,
time delay

Cat. no.
35
35
35
35
35
35
35
35
35

30
30
30
100
300
30
100
300
100

EE40/30/4
EE40/100/4
EE63/30/4
EE63/100/4
EE63/300/4
EE100/30/4
EE100/100/4
EE100/300/4
EES100/100/4

DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR

Contactors DIN-rail Mounted


Exceeds the requirements of EN 61095
May require de-rating when used with inductive loads see Contactor De-rating
table in the Technical Applications section

Contactor
40A, 4-pole
63A, 4-pole

Cat. no.
-

EE4P40CO
EE4P63CO

DBXCKR
DBXCKR

Fuse Combination Units


Fuse switch
100A, 3-pole
200A, 3-pole

20

Cat. no.
70
150

HBF3P100N
HBF3P200N

DBXLSA1
DBXLSA2

Loadlimiter 63
B-type Incoming Options and Surge Protection
YA3 frame MCCB - 250A Max

Standard cable termination 95mm2


Cable clamps termination - 120mm2
Maximum cable termination is 150mm2 using reduced palm width M8 cable lugs
MCCBs have thermal and magnetic overloads except switch disconnector
To be mounted in incoming housing (DBXYA3)

Device type

Max. cable

Icu

Incoming device

(mm2)
63A, 3-pole
63A, 4-pole
100A, 3-pole
100A, 4-pole
125A, 3-pole
125A, 4-pole
160A, 3-pole
160A, 4-pole
200A, 3-pole
200A, 4-pole
250A, 3-pole
250A, 4-pole
250A, 3-pole
switch disconnector
250A, 4-pole
switch disconnector

150*
150*
150*
150*
150*
150*
150*
150*
150*
150*
150*
150*
150*
150*

cat. no.
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
-

YA3N3P63T
YA3N4P63T
YA3N3P100T
YA3N4P100T
YA3N3P125T
YA3N4P125T
YA3N3P160T
YA3N4P160T
YA3N3P200T
YA3N4P200T
YA3N3P250T
YA3N4P250T
YA3B3P250D

YA3B4P250D

* 150mm2 based on using reduced palm width cable lugs

Direct Connection Terminal Kits

Description

Max. cable (mm2)

Picture

Cat. no.

Terminals
Terminals
Terminals

35
70
150

1
2
3

DBXD0
DBXD1
DBXD2

3
1

Surge Protection

Plug-in surge protection modules


Integral protection status indicator
Thermal and current overload fusing
Three-phase operating range, 380-515V rms max
Hot working replaceable modules

Device type

Width (mm) Cat. no.

3-phase with neutral/earth surge protection module


MOV replacement plug-in SPM
MOV neutral/earth replacement plug-in SPM

54
17.5
17.5

DSPM3PN
DSPML
DSPMNE

Note: Connection kit DBXCKR must be ordered to provide the additional DIN-rail
needed to mount this device in the distribution enclosure below the incoming
device (for 125A max only). For 250A applications devices should be mounted in a
service centre.

21

Loadlimiter 63
DB-type Outgoing Devices
Single-pole MCBs

Exceeds the requirements of EN 60898


10kA rated breaking capacity to EN60898
15kA rated breaking capacity to EN60947-2
Contact position indicator
35mm2 cable capacity

Current
rating (A)

B type
cat. no.

C type
cat. no.

D type
cat no.

6
10
13
16
20
25
32
40
50
63

K1PB06
K1PB10
K1PB13
K1PB16
K1PB20
K1PB25
K1PB32
K1PB40
K1PB50
K1PB63

K1PC06
K1PC10
K1PC13
K1PC16
K1PC20
K1PC25
K1PC32
K1PC40
K1PC50
K1PC63

K1PD06
K1PD10
N/A
K1PD16
K1PD20
K1PD25
K1PD32
T1PD40*
T1PD50*
T1PD63*

Current
rating (A)

B type
cat. no.

C type
cat. no.

D type
cat no.

6
10
13
16
20
25
32
40
50
63

K3PB06
K3PB10
K3PB13
K3PB16
K3PB20
K3PB25
K3PB32
K3PB40
K3PB50
K3PB63

K3PC06
K3PC10
N/A
K3PC16
K3PC20
K3PC25
K3PC32
K3PC40
K3PC50
K3PC63

K3PD06
K3PD10
N/A
K3PD16
K3PD20
K3PD25
K3PD32
T3PD40*
T3PD50*
T3PD63*

Triple-pole MCBs

* 6kA/10kA - EN60898/EN60947-2

22

Loadlimiter 63
B-type Outgoing Devices and Accessories
Single Module RCBOs

Exceeds the requirements of EN 61009


Single module: Type AC
10kA rated breaking capacity
Terminal capacity: outgoing terminals 10mm2
Terminal capacity: busbar side terminals 35mm2

Current
rating (A)

Sensitivity
(mA)

B type
cat. no.

C type
cat no.

6
10
16
20
32
40
45
6
10
16
20
32
40

30
30
30
30
30
30
30
100
100
100
100
100
100

KR1PB0630
KR1PB1030
KR1PB1630
KR1PB2030
KR1PB3230
KR1PB4030
KR1PB4530
-

KR1PC0630
KR1PC1030
KR1PC1630
KR1PC2030
KR1PC3230
KR1PC4030
KR1PC4530
KR1PC06100
KR1PC10100
KR1PC16100
KR1PC20100
KR1PC32100
KR1PC40100

Double Module RCBOs


Energy limiting class 3
Type AC
Terminal capacity: outgoing
terminals 35mm2
Terminal capacity: busbar side
terminals 35mm2

Exceeds the requirements of


EN 61009, IEC 61009
SP&SwN configuration
Rated breaking capacity up to 10kA
Contact position indicator
Rated voltage Ue ~230V
Rated frequency 50Hz

Current rating (A)

Sensitivity (mA)

B type cat. no.

C type cat. no.

6
10
16
20
32
40

30
30
30
30
30
30

KR2PB0630
KR2PB1030
KR2PB1630
KR2PB2030
KR2PB3230
KR2PB4030

KR2PC0630
KR2PC1030
KR2PC1630
KR2PC2030
KR2PC3230
KR2PC4030

Accessories for MCBs and RCBOs


Auxiliary equipment

Picture

Cat. no.

MCB shunt trip (240V AC)

KST240

MCB auxiliary/switch contact

KAUX1

Padlocking

Picture

Cat. no.

MCB dolly locking device


Padlock for dolly locking device

KDL
XPL

23

Loadlimiter 63
B-type Modular Devices
Double-pole RCCBs

Exceeds the requirements of EN 61008


Voltage 230/400V 50/60Hz
Type AC
Terminal capacity: 40A-63A: 25mm2
Terminal capacity: 100A: 35mm2
Current rating (A)

Sensitivity (mA)

Type

Width (mm)

Cat. no.

40
40
63
63
63
100
100
100, time delay

30
100
30
100
300
30
100
100

AC
AC
AC
AC
AC
AC
AC
AC

35
35
35
35
35
35
35
35

Sensitivity (mA)

Type

Width (mm)

Cat. no.

AC
AC
AC
AC
AC
AC
AC
AC
AC
AC

70
70
70
70
70
70
70
70
70
70

EE40/30/4
EE40/100/4
EE40/300/4
EE63/30/4
EE63/100/4
EE63/300/4
EE100/30/4
EE100/100/4
EE100/300/4
EES100/100/4

EE40/30/2
EE40/100/2
EE63/30/2
EE63/100/2
EE63/300/2
EE100/30/2
EE100/100/2
EES100/100/2

Four-pole RCCBs
Current rating (A)
40
40
40
63
63
63
100
100
100
100, time delay

30
100
300
30
100
300
30
100
300
100

Programmable Timers DIN-rail Mounted


250V ac 50/60Hz
Running reserve of 3 years
Switching capacity 150mA
Current rating (A)

Function

Width (mm)

Cat. no.

16A (AC7A)

1 or 2 channel

35

DRT-DW2R

When controlling highly inductive loads, a suitably rated contactor should be


employed with timers, programmers and relays.

Contactors DIN-rail Mounted


Exceeds the requirements of EN 61095
May require de-rating when used with inductive loads see Contactor De-rating
table in the Technical Applications section
Current rating (A)

Width (mm)

Contacts

Cat. no.

20A
20A
25A
25A
40A
40A
63A
63A
Venting kit *

17.5
35
35
35
54
54
54
54
9

2P N/O
2P N/C
4P N/O
4P N/C
4P N/O
4P N/C
4P N/O
4P N/C
-

EE2P20CO
EE2P20CC
EE4P25CO
EE4P25CC
EE4P40CO
EE4P40CC
EE4P63CO
EE4P63CC
LLMV

* Ventilation module must be fitted between alternate pairs of contactors


to prevent overheating.

24

Loadlimiter 63
Meters, Current Transformers and Wiring Looms
DIN-rail Mounted Meters for Incoming Circuits
4 modules width
Fully programmable CT ratios

Device type

Outputs

Width (mm)

3-phase analogue kWh meter


3-phase digital kWh meter
1-phase/3-phase digital
multi-function meter

1 pulse
71
1 pulse
71
1 pulse
71
& 1 Modbus

Cat. no.
DRK-3PCT-415
DRK-3PCT-415-LCD
RI3-01

Note: Connection kit DBXCKR must be ordered to provide the additional DIN-rail
needed to mount these devices integral to distribution board below the
incoming disconnector.

Panel Mounted Meters for Incoming Circuits

96mm x 96mm dimensions


Low profile
Fully programmable CT ratios
Can be configured single or three phase

Device type

Outputs

Width (mm)

Cat. no.

1-phase/3-phase digital
kWh meter
1-phase/3-phase digital
multi-function meter
1-phase/3-phase digital
multi-function meter
1-phase/3-phase digital
multi-function meter
Optional pulse plug-in
module for Ci meter
RS485 Modbus plug-in
module for Ci meter

1 pulse

96

CI1-01-PUL

1 pulse

96

INT-1630-M-5-M-100

1 pulse &
1 Modbus
1 pulse

96

INT-1630-M-5-M-110

96

CI3-01-PUL

CI-PUL-01

CI-MOD-01

DIN-rail Mounted Kilowatt Hour Meters for Outgoing Circuits


In-built current transformers, direct connection
DIN-rail mountable in Loadlimiter 63 service centres
Phase cable hole diameter 12.5mm

Device type

Outputs

Width (mm)

Cat. no.

1-phase digital kWh meter


with integral 63A current
transformer
3-phase digital kWh meter
with integral 100A current
transformers

1 pulse

54

DRK-1P-230-D63

1 pulse

126

DRK-3P-400-D100

25

Loadlimiter 63
Meters, Current Transformers and Wiring Looms
Measuring Current Transformers

Up to Class 0.5 accuracy


System voltage up to 720V
Secondary output of 5A
Operating temperature range of 20C to +70C

Max Cable mm2

Description
100A 3-in-1 CT case size 35mm
125A 3-in-1 CT case size 35mm
200A 3-in-1 CT case size 35mm
250A 3-in-1 CT case size 35mm
Meter spreader box

95*/150**
95*/150**
95*/150**
95*/150**
-

Cat. no.
M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5
DBMSB

* 95mm2 using standard cable lugs


**150mm2 using reduced palm width lugs

Wiring Looms for TP&N Applications


(refer to page 33 for application details)
1A fuse (rated 400V) metering harness
Current transformer harness

Description

For use with


distribution boards

Suitable meter

Cat. no.

Wiring loom
for single meter
Wiring loom
for single meter
Wiring loom for
single meter for
top distribution
board (vertical
stacking)

DBX04R DBX16R

Any Crompton
Instruments meter
Any Crompton
Instruments meter
Any Crompton
Instruments meter

DBXW16

DBX20R DBX24R
DBX04R DBX16R

DBXW24
DBXW16T

Note: Meters, current transformers and enclosure to be ordered separately.

Power Loom for Sub-Metered Distribution Boards


(refer to page 33 for application details)
125A and 250A power loom for joining two distribution boards

26

Description

Current rating

Cat. no.

Power loom for sub metered


distribution board
Power loom for sub metered
distribution board

125A max

DBXWP125

250A max

DBXWP250

Loadlimiter 63
B-type Assembled Boards Range
125A - Horizontal Arrangement with Two Multi-function Meters
Two 125A switch disconnectors fitted:
One for isolation of whole arrangement
One for isolation of lighting circuits only
Two meter displays for separate readings of power and lighting consumption
All power and control wiring fully tested and fitted
Multi-function meter with pulse output for connection to a compatible BMS system
No. of power
TP ways

No. of TP
lighting ways

Dimensions
HxWxD

Cat. no.

6
12

6
12

811 x 968 x 160


971 x 968 x 160

DBXC06NAH06CA
DBXC12NAH12CA

125A - Vertical Arrangement with One Multi-function Meter (Lighting Only)


Two 125A switch disconnectors fitted:
One for Isolation of whole arrangement
One for isolation of lighting circuits only
One meter display for readings of lighting consumption only
All power and control wiring fully tested and fitted
Multi-function meter with pulse output for connection to a compatible BMS system
No. of power
TP ways

No. of TP
lighting ways

Dimensions
HxWxD

Cat. no.

8
12

6
8

1452 x 484 x 160


1612 x 484 x 160

DBXC08NNV06CA
DBXC12NNV08CA

125A - Vertical Arrangement with Two Meters (kWh or Multi-function)


Two 125A switch disconnectors fitted:
One for Isolation of whole arrangement
One for isolation of lighting circuits only
Two meter displays for separate readings of power and lighting consumption
All power and control wiring fully tested and fitted
Both meters have a pulse output for connection to a compatible BMS system
Meter
type

No of power No of TP
TP ways
lighting ways

Dimensions
HxWxD

Cat. no.

Multi-function
Multi-function
Multi-function
kWh
kWh

6
8
12
8
12

1345 x 484 x 160


1452 x 484 x 160
1612 x 484 x 160
1452 x 484 x 160
1612 x 484 x 160

DBXC06NAV04CA
DBXC08NAV06CA
DBXC12NAV08CA
DBXC08NJV06CJ
DBXC12NJV08CJ

4
6
8
6
8

250A - Vertical Arrangement with Two Meters (kWh or Multi-function)

One 250A switch disconnector fitted providing isolation for whole arrangement
Two meter displays for separate readings of power and lighting consumption
All power and control wiring fully tested and fitted
Both kWh and multi-function meters have a pulse output for connection to a
compatible BMS system
Meter
type

No. of power No. of TP


TP ways
lighting ways

Dimensions
HxWxD

Cat. no.

Multi-function
Multi-function
kWh
kWh

8
12
8
12

1570 x 484 x 160


1730 x 484 x 160
1570 x 484 x 160
1730 x 484 x 160

DBXE08NAV06NA
DBXE12NAV08NA
DBXE08NJV06NJ
DBXE12NJV08NJ

6
8
6
8

250A - Horizontal Arrangement with Two Multi-function Meters

One 250A switch disconnector fitted providing isolation for whole arrangement
Two meter displays for separate readings of power and lighting consumption
All power and control wiring fully tested and fitted
Both kWh and multi-function meters have a pulse output for connection to a
compatible BMS system
No. of power
TP ways

No. of TP
lighting ways

Dimensions
HxWxD

Cat. no.

972 x 968 x 160

DBXE08NAH08NA

Customised assembled boards available

Loadlimiter 63 Selection Chart - B-type


B-type Distribution Boards (without incoming device)
Busbar rating
TP outgoing ways Height (mm)
250A
250A
250A
250A
250A
250A
250A

4
6
8
12
16
20
24

544
598
651
758
865
1025
1132

Weight (kg)

Cat. no.

10
11
12
15
18
22
27

DBX04R
DBX06R
DBX08R
DBX12R
DBX16R
DBX20R
DBX24R

B-type Incoming YA3 MCCB Enclosure


Height (mm)

Weight (kg)

Cat. no.

3-pole housing
4-pole housing

321
321

8
8

DBXYA3
DBXYA3

B-type Service Centres


For use with DIN-rail modules

Height (mm)

Weight (kg)

Cat. no.

18 x 1-pole ways (single row)


36 x 1-pole ways (double row)
Cable spreader box

213
427
213

5
8
3

DBS18X
DBS36X
DBMSB

B-type Distribution Boards (complete with incoming device/s)


Busbar rating
TP outgoing ways
Height (mm) Width (mm)

Arrangement

Meters

Cat. no.

125
125
125
125
125
125
125
125
125
250
250
250
250
250

Horizontal
Horizontal
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Vertical
Horizontal

2 x MF
2 x MF
1 x MF
1 x MF
2 x MF
2 x MF
2 x MF
2 x kWh
2 x kWh
2 x MF
2 x MF
2 x MF
2 x MF
15 x MF

DBXC06NAH06CA
DBXC12NAH12CA
DBXC08NNV06CA
DBXC12NNV08CA
DBXC06NAV04CA
DBXC08NAV06CA
DBXC12NAV08CA
DBXC08NJV06CJ
DBXC12NJV08CJ
DBXE08NAV06NA
DBXE12NAV08NA
DBXE08NJV06NJ
DBXE12NJV08NJ
DBXE08NAH08NA

6/6
12/12
8/6
12/8
6/4
8/6
12/8
8/6
12/8
8/6
12/8
8/6
12/8
8/8

811
971
1452
1612
1345
1452
1612
1452
1612
1570
1730
1570
1730
972

968
968
484
484
484
484
484
484
484
484
484
484
484
968

Accessories for all B-type Distribution Boards


Description
Conversion kits plus spares
TP&N to SP&N conversion kit
Spare end plate
RCCB, Contactor, 4-pole switch disconnector connection kit
Fixing kit for 24 way distribution boards
Blank way label for 24 way distribution boards
Blanking pieces
MCB blanks (4xTP MCB ways + 12 busbar terminal blanks)
MCB blanks (5xSP MCB ways + 5 busbar terminal blanks)
MCB blanks (5x12 MCB Ways)
Joining kit
Mechanical joining kit (For joining two distribution boards vertically)
Terminal bars
Terminal bar for 6 ways
Terminal bar for 12 ways
Terminal bar for 18 ways
Terminal bar for 24 ways
Blanking kits
Busbar terminal blanks (set of 10)
Earth bar kits
Earth bar
Earth bar isolation kit
Double earth bar facility
Earth bar kit with terminal for each outgoing way
(where ** = 04, 06, 08, 12, 16, 20 or 24 ways)
Door lock kits
Cylinder door lock
Padlock bracket kit

28

Cat. no.

DBXTS
DBXEP
DBXCKR
DBX24FK
DBX24WL
DBXBP
DBXBM
DBXBH
DBXJK
DBXT06
DBXT12
DBXT18
DBXT24
DAXTP
DAXEB
DBXL

DBTE**X
DBXCL
DBXPL

Loadlimiter 63 Selection Chart - B-type


Incoming Devices
Device type

Max. cable
(mm2)

Sensitivity
(mA)

Incoming device
cat. no.

Connection kit
cat. no.

Switch disconnector
100A, 3-pole
100A, 4-pole
125A, 3-pole
125A, 4-pole
250A, 3-pole
250A, 4-pole

50
50
50
50
150
150

AV3100
AV4100
AV3125
AV4125
YA3B3P250D
YA3B4P250D

N/A
DBXCKR
N/A
DBXCKR
DBXYA3
DBXYA3

4-pole RCCB
40A, type AC
40A, type AC
63A, type AC
63A, type AC
63A, type AC
100A, type AC
100A, type AC
100A, type AC

35
35
35
35
35
35
35
35

30
100
30
100
300
30
100
300

EE40/30/2
EE40/100/2
EE63/30/4
EE63/100/4
EE63/300/4
EE100/30/4
EE100/100/4
EE100/300/4

DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR
DBXCKR

Contactor
40A, 4-pole
63A, 4-pole

EE4P40CO
EE4P63CO

DBXCKR
DBXCKR

Fuse switch
100A, 3-pole
200A, 3-pole

70
150

HBF3P100N
HBF3P200N

DBXLSA1
DBXLSA2

Direct connection

Max. cable (mm2)

Cat. no.

Terminals
Terminals
Terminals

35
70
150

DBXD0
DBXD1
DBXD2

Surge suppression

Cat. no.

Connection kit for surge suppression


3-phase with neutral/earth surge protection module
MOV replacement plug-in SPM
MOV neutral/earth replacement plug-in SPM

DBXCKR
DSPM3PN
DSPML
DSPMNE

Current Transformers
Description

100A current transformer


125A current transformer
200A current transformer
250A current transformer

Cable
aperture (mm)

Height
(mm)

Weight
(kg)

Cat. no.

25
25
25
25

80
80
80
80

<1
<1
<1
<1

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

B-type Metering
Device type

3-phase DIN-rail mounting analogue kWh meter


3-phase DIN-rail mounting digital kWh meter
1-phase/3-phase DIN-rail mounting digital
multi-function meter
1-phase/3-phase digital kWh meter
1-phase/3-phase digital multi-function meter
1-phase/3-phase digital multi-function meter
1-phase/3-phase digital multi-function meter
Optional pulse plug-in module for Ci meter
RS485 Modbus plug-in module for Ci meter
1-phase DIN-rail mounting digital kWh meter
with integral 63A current transformer
3-phase DIN-rail mounting digital kWh meter
with integral 100A current transformers

Outputs

Width (mm)

Cat. no.

1 pulse
1 pulse

71
71

DRK-3PCT-415
DRK-3PCT-415-LCD

1 pulse & 1 Modbus


1 pulse
1 pulse
1 pulse & 1 Modbus
1 pulse

1 pulse

71
96
96
96
96

54

RI3-01
CI1-01-PUL
INT-1630-M-5-M-100
INT-1630-M-5-M-110
CI3-01-PUL
CI-PUL-01
CI-MOD-01
DRK-1P-230-D63

1 pulse

126

DRK-3P-400-D100

29

Loadlimiter 63 Selection Chart - B-type


TP&N B, C & D types
10kA/15kA breaking capacity Current rating (A)

B type cat. no.

C type cat. no.

D type cat. no.

1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole

6
10
13
16
20
25
32
40
50
63

K1PB06
K1PB10
K1PB13
K1PB16
K1PB20
K1PB25
K1PB32
K1PB40
K1PB50
K1PB63

K1PC06
K1PC10
K1PC13
K1PC16
K1PC20
K1PC25
K1PC32
K1PC40
K1PC50
K1PC63

K1PD06
K1PD10
N/A
K1PD16
K1PD20
K1PD25
K1PD32
T1PD40*
T1PD50*
T1PD63*

3-pole
3-pole
3-pole
3-pole
3-pole
3-pole
3-pole
3-pole
3-pole
3-pole
3-pole

6
10
13
16
20
25
32
40
50
63

K3PB06
K3PB10
K3PB13
K3PB16
K3PB20
K3PB25
K3PB32
K3PB40
K3PB50
K3PB63

K3PC06
K3PC10
N/A
K3PC16
K3PC20
K3PC25
K3PC32
K3PC40
K3PC50
K3PC63

K3PD06
K3PD10
N/A
K3PD16
K3PD20
K3PD25
K3PD32
T3PD40*
T3PD50*
T3PD63*

* 6kA/10kA - EN60898/EN60947-2
RCBOs
10kA breaking
capacity, AC type

Current
rating (A)

Sensitivity
(mA)

B type
cat. no.

C type
cat. no.

1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole
1-pole

6
10
16
20
32
40
45
6
10
16
20
32
40

30
30
30
30
30
30
30
100
100
100
100
100
100

KR1PB0630
KR1PB1030
KR1PB1630
KR1PB2030
KR1PB3230
KR1PB4030
KR1PB4530
-

KR1PC0630
KR1PC1030
KR1PC1630
KR1PC2030
KR1PC3230
KR1PC4030
KR1PC4530
KR1PC06100
KR1PC10100
KR1PC16100
KR1PC20100
KR1PC32100
KR1PC40100

Accessories for MCBs and RCBOs


Auxiliary equipment

Cat. no.

MCB shunt trip (240V AC)


MCB auxiliary/switch contact

KST240
KAUX1

Padlocking
MCB dolly locking device
Padlock for dolly locking device

KDL
XPL

Blanking pieces
MCB blanks (4xTP MCB ways + 12 busbar terminal blanks)
MCB blanks (5xSP MCB ways + 5 busbar terminal blanks)
MCB blanks (5x12 MCB ways)

DBXBP
DBXBM
DBXBH

30

Loadlimiter 63 Selection Chart - B-type


2-pole RCCB
Description

Current rating (A)

Function

Width (mm)

Cat. no.

Type AC
Type AC
Type AC
Type AC
Type AC
Type AC
Type AC
Type AC
Type AC time delay

40
40
63
63
63
80
100
100
100

30mA
100mA
30mA
100mA
300mA
30mA
30mA
100mA
100mA

35
35
35
35
35
35
35
35
35

EE40/30/2
EE40/100/2
EE63/30/2
EE63/100/2
EE63/300/2
EE80/30/2
EE100/30/2
EE100/100/2
EES100/100/2

4-pole RCCB
Description

Current rating (A)

Sensitivity

Width (mm)

Cat. no.

Type
Type
Type
Type
Type
Type
Type
Type
Type

40
40
63
63
63
80
100
100
100

30mA
100mA
30mA
100mA
300mA
30mA
30mA
100mA
100mA

70
70
70
70
70
70
70
70
70

EE40/30/4
EE40/100/4
EE63/30/4
EE63/100/4
EE63/300/4
EE80/30/4
EE100/30/4
EE100/100/4
EES100/100/4

16A (AC7A)

1 or 2 channel

35

DRT-DW2R

Contacts

Width (mm)

Cat. no.

20

2P N/O

17.5

EE2P20CO

20

2P N/C

17.5

EE2P20CC

25

4P N/O

35

EE4P25CO

25

4P N/C

35

EE4P25CC

40

4P N/O

35

EE4P25CC

40

4P N/C

35

EE4P40CC

63

4P N/O

54

EE4P63CO

63

4P N/C

54

EE4P63CC

LLMV

AC
AC
AC
AC
AC
AC
AC
AC
AC time delay

Programmable Timer
Timer

Contactor
Modular contactor,
AC1 230V
Modular contactor,
AC1 230V
Modular contactor,
AC1 400V
Modular contactor,
AC1 400V
Modular contactor,
AC1 400V
Modular contactor,
AC1 400V
Modular contactor,
AC1 400V
Modular contactor,
AC1 400V
Venting kit

Current Rating (A)

31

Loadlimiter 63
Outline Drawings and Dimensions
B-type Distribution Boards (without incoming device)

3-pole ways

Drawing
no.

Height
(mm)

Weight
(kg)

Cat. no.

4
6
8
12
16
20
24

1
1
1
1
1
1
1

544
598
651
758
865
1025
1132

10
11
12
15
18
22
27

DBX04R
DBX06R
DBX08R
DBX12R
DBX16R
DBX20R
DBX24R

YA3 Frame MCCB Enclosure for B-type Distribution Boards


Incomer

Drawing
no.

Height
(mm)

Weight
(kg)

Cat. no.

3-pole MCCB
4-pole MCCB

2
2

321
321

8
8

DBXYA3
DBXYA3

Modular ways

All dimensions in mm

32

18 x 1-pole ways
(single row)
36 x 1-pole ways
(double row)
General purpose
enclosure

Height (mm)

Weight (kg)

Cat. no.

213

DBS18X

427

DBS36X

213

DBMSB

Supplied without top or bottom plate. Intended for use with removable plate from
distribution board.

Loadlimiter 63 Metering Selection Chart


Split Metered Power & Lighting Board

Single Board

Select dist board x2

Select dist board x1

DBX04R
DBX06R
DBX08R
DBX12R
DBX16R
DBX20R
DBX24R

DBX04R
DBX06R
DBX08R
DBX12R
DBX16R
DBX20R
DBX24R

Select incomer

Select incomer
125A

250A

Switch disconnectors (125A max)


AV3125
AV3100
AV4125
AV4100
Meter enclosure (125A)
DBMSB x1

Power loom (125A)

125A Incomer

Switch disconnectors (250A max)


YA3B3P250D
YA3B4P250D
Or any YA3 MCCB

Meter enclosure (250A)

Switch disconnectors
YA3B3P250D
YA3B4P250D
Or Any YA3
MCCB
Meter enclosure (250A)

Integral

Spreader box

DBXYA3 x1

250A Incomer

Switch disconnectors
AV3100
AV3125
AV4100
AV4125

Meter enclosure
(125A)

DBXYA3

DIN-rail
mounting kit

Power loom (250A)


DBMSB

DBXWP125 x1

Cable connection terminals


DBXD0
see table 1

Current transformers (125A)


M3N1-35-100/5
M3N1-35-125/5

DBXCK **

DBXWP250 x1

Select meter

Cable connection terminals

INT-1630-M-5-M-100
CI1-01-PUL
RI3-01

DBXD0
see table 1

Current transformers (250A)


M3N1-35-200/5
M3N1-35-250/5

CI3-01-PUL

Modbus available

Select CT x3
Current transformers

Select meter x2

M3N1-35-100/5
M3N1-35-125/5

INT-1630-M-5-M-100
CI1-01-PUL
(Multi-function)
CI3-01-PUL
Modbus available

Vertical Arrgt
Vertical joining kit

Select meter wiring


loom x1

Horizontal Arrgt

DBXW16
OR
DBXW24

Meter enclosure (DB 2)


DBXJK

Select meter wiring loom


x1 for bottom board
DBXW16
OR
DBXW24

M3N1-35-200/5
M3N1-35-250/5

DBMSB

Select meter
wiring loom x2

Cable connection terminals

DBXW16
OR
DBXW24

DBXD0
see table 2

Select meter wiring


loom x1 for top board
Select outgoing devices

DBXW16T*

** Meter RI3-01 only

Select outgoing devices


* Top board max size 16 way (vertical arrangement only)

Table 1

Table 2

Quantity of AV
(switch disconnectors)

DBXD0's
required (125A)

DBXD0'S
required (250A)

DBXCK
required

1
2
2

5
4
3

3
2
N/A

0
0
1

DBXD0s
DBXD0
DBXWP125
required 125A required 250A (125A rated only)

Main incomer
mounted in DBMSB
Main incomer mounted
in standard position

33

Flow Chart Examples


Example 1 Requirement Vertically stacked, 125A split metered
power and lighting distribution board
8 way TP&N power board
6 TP&N lighting board
Multi-function meters

Example 1: Bill of Material List


Cat. no.

Quantity

Description

DBX08R
DBX06R
AV3125
DBMSB

1
1
1
1

DBXJK

DBXWP125

INT-1630-M-5-M-100

DBXW16
DBXW16T

1
1

DBXD0
M3N1-35-125/5

5
2

8 way TP&N distribution board


6 way TP&N distribution board
125A 3P switch disconnector
Spreader box with facility to mount 2 panel
mounted meters
Mechanical joining kit for joining two
vertically stacked distribution boards
Power loom for split metered distribution
board (125A)
3-Phase Integra 1630 multi-function meter
with 1 pulse output
Wiring loom for single meter
Wiring loom for single meter for top
distribution board when vertically stacked
Cable joining terminal kit
125A 3-in-1 current transformers

Split metered 125A

Example 2 Requirement Single Metered Distribution Board (250A)


24 way TP&N distribution board
KWh meter

Example 2: Bill of Material List


Cat. no.

Quantity

Description

DBX24R
YA3B3P250D
DBXYA3

1
1
1

CI1-01-PUL

DBXW24
DBXD0
M3N1-35-250/5

1
1
1

24 way TP&N distribution board


250A3P MCCB switch disconnector
250A incoming enclosure with facility to
mount 2 panel mounted meters
3-phase Kilowatt hour meter with 1 pulse
output (panel mounted)
Wiring loom for single meter
Cable joining terminal kit
250A current transformers

Split metered 250A

Single metered 125A & 250A

34

Section

MCCB Panel Boards


Loadbank 125 Range (250A and 400A Ratings)

Overview
Key Features
ASTA certified busbars with a
short circuit rating of 25kA for
1 second (250A) and 25kA for 3
seconds (400A)
Shunts, UVRs and auxiliaries
are common for YA2, YA3 and
YA5 MCCBs
Single frame size outgoing
MCCBs from 16A to 125A
Generous cable-spreading
space for incoming and
outgoing cables
Common width (700mm) and
depth (190mm) for all enclosures
A single part number identifies
the complete main enclosure

Available Options
250A panel boards with 6, 8 or
12 triple-pole outgoing ways can
choose incoming devices from
the YA3 MCCB range or a
direct connection
400A panel boards with 6, 8, 12
or 16 triple-pole outgoing ways
can choose incoming devices
from the YA5 MCCB range or a
direct connection
Panel build options include:
Cable spreader box
Service centre with 24
single-pole ways
Integra metering housing
YA3 frame outgoing housing

Additional Features
Neutral and earth terminal for
each single-pole way
Clean earth facility
250A panels use YA3 MCCBs for
incoming devices
400A panels use YA5 MCCBs
for incoming devices
All versions use YA2 MCCBs for
outgoing devices
All triple-pole MCCBs have
adjustable overload and
instantaneous trips

Compliance
Panel boards
MCCBs

36

EN 60439-1
EN 60947-2

Featuring busbar ratings of 250A and 400A with seven


MCCB panel board designs Loadbank 125 system offers
an uncomplicated solution for power distribution in
commercial and industrial applications. Outgoing devices
consist of a single frame size utilising the Loadline YA2
frame as a cost effective option for circuit protection.
New developments include ASTA certified busbars with a
short-circuit withstand rating of 25kA-3sec (400A
busbars only) and Form 3 separation is now as standard.
Available options now include a versatile range of
accessories for both incoming and outgoing metering for
compliance with Part L2 Building Regulations. A
multitude of add-on enclosures, including service centres
and a unique outgoing housing for 160A to 250A YA3
frame MCCB matching the dimensional profile of the
standard enclosure.
The standard finish is epoxy powder coating in light grey
RAL 7035.

MCCB Panel Boards (250A and 400A Rating)

MCCB Panel Boards


Service centres
Metering enclosures

Incoming Devices
Switch disconnector
Moulded case circuit breakers

Circuit Protection Devices


Moulded case circuit breakers (125A max)

Modular Devices
Surge protection
Meters, current transformers and
wiring looms
Contactors
Timer
Earth leakage device

37

Loadbank 125
250A Panel Board Enclosures Form 3 25kA-1sec
250A Panel Board Enclosures

ASTA certified busbars rated 25kA-1sec


Form 3 with outgoing terminals shields fitted
IP4X protection rating
Optional incoming terminal shield available
Accepts single frame size YA2 MCCB (Max 125A) outgoing devices

No. of TP
outgoing ways

Incoming device
type

Height
(mm)

Width
(mm)

Depth
(mm)

Cat. no.

6
8
12

YA3 frame
YA3 frame
YA3 frame

904
994
1174

700
700
700

190
190
190

PB206YA
PB208YA
PB212YA

250A Panel Board Accessories


Description

Cat. no.

3-pole incoming terminal shroud


4-pole incoming terminal shroud
Door cylinder lock
Door padlock device
3-pole blanking piece
4-pole incoming connection kit

YA3TS3P
YA3TS4P
DBXCL
DBXPL
LBYA2BP3P
PB4PNC250

250A Panel Board Incoming Devices

Standard cable termination 95mm2


Maximum cable termination is 150mm2 using reduced palm width M8 cable lugs
MCCBs have thermal and magnetic overloads except switch disconnector
Four-pole incoming devices require adapter kit
YA3 cable clamp termination 120mm2 (sold separately)

Incoming
device type

Current rating
(A)

No. of poles

Cat. no.

Switch disconnector
MCCB
MCCB
MCCB
Switch disconnector
MCCB
MCCB
MCCB

250
160
200
250
250
160
200
250

3
3
3
3
4
4
4
4

YA3B3P250D
YA3N3P160T
YA3N3P200T
YA3N3P250T
YA3B4P250D
YA3N4P160T
YA3N4P200T
YA3N4P250T

250A and 400A Panel Board Accessories Add-on Units


Cable spreader box
24 way service centre
Housing to accommodate outgoing YA3 MCCB

38

Description

Height (mm)

Cat. no.

Cable spreader box


Service centre with 24-1 pole ways
160A250A YA3 outgoing housing

270
270
450

PBYA2CSB
PBYA2SC24
PBYA2OG

Loadbank 125
400A Panel Board Enclosures Form 3 25kA-3secs
400A Panel Board Enclosures

ASTA certified busbars rated 25kA-3secs


Form 3 as standard
IP4X protection rating
Optional incoming terminal shield available
Accepts single frame size YA2 MCCB (Max 125A) outgoing devices

No. of TP
outgoing ways

Incoming device
type

Height
(mm)

Width
(mm)

Depth
(mm)

Cat. no.

6
8
12
16

YA5
YA5
YA5
YA5

1084
1174
1354
1534

700
700
700
700

190
190
190
190

PB406YA
PB408YA
PB412YA
PB416YA

frame
frame
frame
frame

400A Panel Board Accessories


Description

Picture number

Cat. no.

3-pole incoming terminal shroud


4-pole incoming terminal shroud
Door cylinder lock
Door padlock device
3-pole blanking piece
4-pole incoming connection kit

2
3

YA5TS3P
YA5TS4P
DBXCL
DBXPL
LBYA2BP3P
PB4PNC400

400A Panel Board Incoming Devices

Standard cable termination 95mm2


Maximum cable termination is 185mm2 using reduced palm width M8 cable lugs
MCCBs have thermal and magnetic overloads except switch disconnector
Four-pole incoming devices require adapter kit

Incoming
device type

Current rating
(A)

No. of poles

Cat. no.

Switch disconnector
MCCB
MCCB
Switch disconnector
MCCB
MCCB
Direct connection

400
250
400
400
250
400
400

3
3
3
4
4
4
3/4

YA5B3P400D
YA5N3P250T
YA5N3P400T
YA5B4P400D
YA5N4P250T
YA5N4P400T
PBYA2DC4

39

Loadbank 125
250A/400A Surge Protection and Metering Accessories
Surge Protection Mounting Kits

Easily installed inside panelboard closely located to incoming device


DIN-rail mounting for triple-pole MCB
C/W 30kA three-phase surge protector
Remote status indication
Site fault indication

Description

Height (mm) Cat. no.

Surge protection Loadbank 125 mounting kit


c/w surge protector and remote indicator

435

PBSM

Metering Housing

New stackable meter housing for incoming and outgoing metering


Designed to fit up to six DIN-rail mounted meters (4 mod max)
Can be mounted top or bottom
Includes DIN-rail for facility to mount current transformers and fuses

Description

Height (mm)

Weight

Cat. no.

Meter housing

450

PBYA2MB

Four Module DIN-rail Meter


Description

Cat. no.

Digital multi-function meter with 1 pulse and


1 RS485 Modbus ouput
Analogue kWh meter with 1 pulse

RI3-01
DRK-3PCT-415

Incoming Current Transformers


Description

Max cable size mm2

Cat. no.

250A 3-in-1 CT case size 3


400A 3-in-1 CT case size 3

150
150

M3N1-45-250/5
M3N1-45-400/5

Outgoing Current Transformers


Description

Max cable size mm2

Cat. no.

60A 3-in-1 current transformer


Case size 25mm
100A 3-in-1 current transformer
Case size 25mm
125A 3-in-1 current transformer
Case size 25mm

50

M3N1-25-60/5

50

M3N1-25-100/5

50

M3N1-25-125/5

Metering Harnesses
A collection of meter harnesses for metering incoming and outgoing circuits
Please refer to page 44 for easy selection chart

40

Description

Cat. no.

Incoming meter loom


Voltage tap off loom for outgoing metering
CT harness for 1 meter
Power loom for 6 outgoing meters

PBWI
PBWP
PBWCT
PBWM6

Loadbank 125
250A/400A Outgoing Devices and Accessories
Outgoing Devices

Standard cable termination 35mm2


Maximum cable termination is 70mm2 using reduced palm width M8 cable lugs
3-pole MCCBs have thermal and magnetic overloads
1-pole MCCBs have fixed thermal and magnetic overloads

Device type

Current rating
(A)

1-pole cat. no.


(fixed overloads)

3-pole cat. no.


(adjustable)

YA2
YA2
YA2
YA2
YA2
YA2
YA2
YA2
YA2

16
20
32
40
50
63
80
100
125

YA2N1P16T
YA2N1P20T
YA2N1P32T
YA2N1P40T
YA2N1P50T
YA2N1P63T
YA2N1P80T
YA2N1P100T
YA2N1P125T

N/A
YA2N3P20T
YA2N3P32T
YA2N3P50T
YA2N3P63T
YA2N3P100T
YA2N3P125T

frame
frame
frame
frame
frame
frame
frame
frame
frame

Accessories

Description

Cat. no.

Panel board 3P blanking piece


YA3 4-pole MCCB incoming kit
YA5 4-pole MCCB incoming kit (pic 2)
YA2 cable clamps (1.5-50mm2)
YA3 cable clamps (35-120mm2)
YA5 cable clamps (95-240mm2)
YA2 1-pole terminal shroud
YA2 3-pole terminal shroud
YA3 1-pole terminal shroud
YA3 3-pole terminal shroud (pic 1)
YA5 3-pole terminal shroud
YA3 4-pole terminal shroud
YA5 4-pole terminal shroud
Door cylinder lock
Door padlock device lock
YA2 1-pole dolly lock
YA2 3-pole dolly lock

LBYA2BP3P
PB4PNC250
PB4PNC400
YA2CC3P
YA3CC3P
YA5CC3P
YA2TS1P
YA2TS3P
YA3TS1P
YA3TS3P
YA5TS3P
YA3TS4P
YA5TS4P
DBXCL
DBXPL
Y2DL
YADL1

Shunt trips
YA frame shunt
YA frame shunt
YA frame shunt
YA frame shunt

YAST115AC
YAST240AC
YAST450AC
YAST24DC

trip
trip
trip
trip

100-120V AC
200-240V AC
380-450V AC
24V DC

Under-voltage release
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage

release
release
release
release

100-120V AC
200-240V AC
380-450V AC
24V DC

YAUVR120AC
YAUVR240AC
YAUVR450AC
YAUVR24DC

YADL1 fitted without padlock

41

Loadbank 125 Selection Chart - Panel Boards


250A Panel Boards
Busbar rating ASTA busbar
short circuit rating

Incoming device

Outgoing ways

Cat. no.

250A
250A
250A

YA3 MCCB/switch disconnector


YA3 MCCB/switch disconnector
YA3 MCCB/switch disconnector

6
8
12

PB206YA
PB208YA
PB212YA

No. of poles

MCCB Icu

Cat. no.

25kA for 1 second


25kA for 1 second
25kA for 1 second

Incoming Devices for 250A Panel Boards


Device type
Current rating (A)
Frame size
Switch
Disconnector
MCCB
MCCB
MCCB
MCCB
Switch
Disconnector
MCCB
MCCB
MCCB
MCCB
400A

250
125
160
200
250

YA3
YA3
YA3
YA3
YA3

4
4
4
4
4

N/A
25kA
25kA
25kA
25kA

YA3B3P250D
YA3N3P125T
YA3N3P160T
YA3N3P200T
YA3N3P250T

250
125
160
200
250
-

YA3
YA3
YA3
YA3
YA3
-

4
4
4
4
4
-

N/A
25kA
25kA
25kA
25kA
-

YA3B4P250D
YA3N4P125T
YA3N4P160T
YA3N4P200T
YA3N4P250T
PBYA2DC4

Outgoing ways

Cat. no.

6
8
12
16

PB406YA
PB408YA
PB412YA
PB416YA

No. of poles

MCCB Icu

Cat. no.

400A Panel Boards


Busbar rating ASTA busbar
short circuit rating

Incoming device

400A
400A
400A
400A

YA5
YA5
YA5
YA5

25kA
25kA
25kA
25kA

for
for
for
for

3
3
3
3

seconds
seconds
seconds
seconds

MCCB/switch
MCCB/switch
MCCB/switch
MCCB/switch

Incoming Devices for 400A Panel Boards


Device type
Current rating (A)
Frame size
Switch
Disconnector
MCCB
MCCB
Switch
Disconnector
MCCB
MCCB

disconnector
disconnector
disconnector
disconnector

400
250
400

YA5
YA5
YA5

3
3
3

N/A
25kA
25kA

YA5B3P400D
YA3N3P250T
YA3N3P400T

400
250
400

YA5
YA5
YA5

4
4
4

N/A
25kA
25kA

YA5B4P400D
YA3N4P250T
YA3N4P400T

Auxiliary Units for both 250A & 400A Panel Boards


Description

Cat. no.

Cable spreader box


Service centre with 24 1-pole ways
YA3 MCCB outgoing housing

PBYA2CSB
PBYA2SC24
PBYA2OG

Surge Protection Mounting Kits for 250A and 400A Panelboards


Description

Height (mm)

Cat. no.

Surge protection Loadbank 125 mounting kit c/w surge protector & remote indicator

435

PBSM

42

Loadbank 125 Selection Chart - Panel Boards


Outgoing Devices for 250A & 400A Panel Boards
Device type
Current rating (A)
Frame size

MCCB Icu

1-pole cat. no.

3-pole cat. no.

MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB
MCCB

25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA
25kA

YA2N1P16T
YA2N1P20T
YA2N1P32T
YA2N1P40T
YA2N1P50T
YA2N1P63T
YA2N1P80T
YA2N1P100T
YA2N1P125T

N/A
YA2N3P20T
YA2N3P32T
N/A
YA2N3P50T
YA2N3P63T
N/A
YA2N3P100T
YA2N3P125T

16
20
32
40
50
63
80
100
125

YA2
YA2
YA2
YA2
YA2
YA2
YA2
YA2
YA2

Selection Chart - Accessories


Description

Cat. no.

Panel board 3-pole blanking piece


YA3 4-pole MCCB kit
YA5 4-pole MCCB kit
YA2 cable clamps (1.5-50mm2)
YA3 cable clamps (35-120mm2)
YA5 cable clamps (95-240mm2)
YA2 1-pole terminal shroud
YA2 3-pole terminal shroud
YA3 1-pole terminal shroud
YA3 3-pole terminal shroud
YA5 3-pole terminal shroud
70mm2 outgoing cable clamps for neutral earth
YA3 4-pole terminal shroud
YA5 4-pole terminal shroud
Door cylinder lock
Door padlock device lock
YA2 1-pole dolly locking device
YA2 3-pole dolly locking device

LBYA2BP3P
PB4PNC250
PB4PNC400
YA2CC3P
YA3CC3P
YA5CC3P
YA2TS1P
YA2TS3P
YA3TS1P
YA3TS3P
YA5TS3P
PBYA2NA
YA3TS4P
YA5TS4P
DBXCL
DBXPL
Y2DL
YADL1

Shunt trips
YA frame shunt
YA frame shunt
YA frame shunt
YA frame shunt

YAST115AC
YAST240AC
YAST450AC
YAST24DC

trip
trip
trip
trip

100-120V AC
200-240V AC
380-450V AC
24V DC

Under-voltage release
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage

release
release
release
release

100-120V AC
200-240V AC
380-450V AC
24V DC

YAUVR120AC
YAUVR240AC
YAUVR450AC
YAUVR24DC

Metering Accessories
Description

Cat. no.

Metering enclosure for upto 6 meters


Incoming meter loom
Voltage tap off loom
CT harness for 1 meter
Power loom for 6 outgoing meters
250A 3-in-1 CT case size 3
400A 3-in-1 CT case size 3
60A 3-in-1 current transformer case size 25mm
100A 3-in-1 current transformer case size 25mm
125A 3-in-1 current transformer case size 25mm
Digital multi-function meter with 1 pulse and 1 RS485 Modbus ouput
Analogue kWh meter with 1 pulse output

PBYA2MB
PBWI
PBWP
PBWCT
PBWM6
M3N1-45-250/5
M3N1-45-400/5
M3N1-25-60/5
M3N1-25-100/5
M3N1-25-125/5
RI3-01
DRK-3PCT-415

43

Loadbank 125 Meter Selection Process

Loadbank 125 MCCB Panel Board System


The Loadbank 125 metering facilities consist of DIN-rail
mounted meters used within a housing which can fit up
to 6 meters of four modules. The meter housing can be
stacked top or bottom with facility to mount current
transformers and fuses. We recommend that for
applications with more than 6 outgoing meters the
Loadbank 250 system with metering accessories should
be used. For applications which require single phase
metering please contact the sales office.

Panel-board enclosures
Description

Cat. no.

250A, 6 TP way
250A, 8 TP way
250A, 12 way
400A, 6 way
400A, 8 way
400A, 12 way
400A, 16 way

PB206YA
PB208YA
PB212YA
PB406YA
PB408YA
PB412YA
PB416YA

Description

Cat. no.

Meter housing for up to 6 meters

PBYA2MB

Description

Cat. no.

Incoming meter loom


Voltage tap off loom for outgoing metering
CT harness for 6 outgoing meters
Power loom for 6 outgoing meters

PBWI
PBWP
PBWCT
PBWM6

Description
Digital Multi-function meter with 1 pulse
output and 1 Modbus output
Analogue kilowatt hour meter with
one pulse output

Description
3-in-1
3-in-1
3-in-1
3-in-1
3-in-1
3-in-1

60A current transformers


100A current transformers
125A current transformers
200A current transformers
250A current transformers
400A current transformers

Panel
Board

Meter Box

PB406YA
PB408YA
PB412YA
PB416YA

Outgoing:
PBYA2MB

Outgoing:
PBYA2MB

Incoming:
PBYA2MB

Incoming:
PBYA2MB

Power Tap Off Harness


PBWP 1 Off

Cat. no.

Outgoing Meter
Arrangement

Incoming Meter
Arrangement

RI3-01
DRK-3PCT-415

Incomer Harness
PBWI 1 Off

Cat. no.
M3N1-25-60/5
M3N1-25-100/5
M3N1-25-125/5
M3N1-35-200/5
M3N1-35-250/5
M3N1-45-400/5

Meter Power
Harness

Meters

CT Harness

Current
Transformers

For single phase metering use:


1 CT per phase
INT-1630-M-5-M-100 Integra meter only

44

PB206YA
PB208YA
PB212YA

Up to 6 Meters:
PBWM6 1 Off
Above 6 Meters:
PBWM6 2 Off

DRK-3PCT-415
Ri3-01

DRK-3PCT-415
Ri3-01

PBWCT 1
per Meter

M3N1-25-60/5
M3N1-25-100/5
M3N1-25-100/5

M3N1-35-200/5
M3N1-35-250/5
M3N1-45-400/5

Section

Fuse Switch Panel Boards


Loadbank 200 Range (800A Rating)

Overview
Key Features
ASTA certified short circuit
withstand rating
Allows inclusion of TP&N
and four-pole fuse
switch distribution
Generous cable-spreading
space for incoming and
outgoing cables
Common width (750mm)
and depth (200mm) for
all enclosures

Available Options
800A panel boards with 6 or 10
outgoing fuse switch ways
400A, 630A or 800A fuse
switch incomers
Panel build options include:
SP&N MCB distribution
board for 17 ways
TP&N distribution board
with 6 and 12 ways
TP&N distribution board with
double banks of 12 ways
General purpose enclosures
with uncut front plates
Metering housings and
service centres
Current transformers

Additional Features
Add-on incomer units include
all copper connections and
incoming cable shrouds
Panel and distribution boards
exceed EN 60439-1
requirements
Fully shielded busbars and
interconnections on
distribution boards
Various locking options
IP4X Ingress Protection

Compliance
Switch fuse panel
boards
Skeleton switches

46

EN 60439-1
EN 60947-3

Based on the modular system employed within


Loadbank 250 panel board, Loadbank 200 panel board
is designed to fulfil the need for fuse switch
panelboards upto 800A. Panel board enclosures are
available in either 6 or 10 TP&N outgoing ways
featuring devices from 63A to 200A. Form 2 separation
is provided as standard, with Form 4 shielding as an
available option.
Several incoming options can be selected from 200A to
800A and a comprehensive range of metering facilities
for compliance with Building Regulations Part L2
completes this versatile panel board system.
The standard finish is epoxy powder coating in light
grey RAL 7035.

Fuse Switch Panel Board System (800A)

Fuse Switch Panel Boards


General purpose enclosures
Cableway extention enclosures
Stacking kits

Incoming Devices
Fuse switches (200A-800A)

Circuit Protection Devices


Fuse switches (63A-200A)

Modular Devices
Surge protection
Meters, current transformers and
wiring looms
Contactors
Timer
Residual current circuit breaker

47

Loadbank 200
Fuse Switch Panel Board System Form 2 and 4 50kA-1sec
800A Panel Board Enclosures

Form 2 as standard
Form 4 with optional shielding
IP3X (IP4X with door kit fitted) Ingress Protection
750mm wide x 200mm deep
Integral incoming option available using 200A fuse switch
in available outgoing way

No of TP
outgoing ways

Modular
height

Height
(mm)

Weight
(kg)

Cat. no.

Optional
door kit

6
10

5
8

760
1216

59
98

LF806A
LF810A

MXD06
MXD10

Fuse Switch Panel Board Accessories


Description

Cat. no.

Form 4 shielding for cable up to 70mm2 (1 per device required)


Form 4 shielding for outgoing cables to 150mm2 (1 per device required)
Vertical stacking connection kit
Blank cover for fuse switch handle

LFS41A
LFS42A
LCFVK
LFXHBA

Add-on Incoming Enclosures

Excludes incoming device (to be ordered separately)


Supplied with all necessary copper connections
Incoming terminations fully shrouded
Supplied with two side plates only
IP4X Ingress Protection

Current
rating
(A)

Modular
height

400
5
630/800 6

Height
(mm)

Weight
(kg)

Device type

Cat. no.

762
914

50
67

L frame fuse switch


N frame fuse switch

LF1F4A
LF1F8A

Exceeds the requirements of


EN 60947-3
80kA rms fused short-circuit capacity
AC23A utilisation category
Full uninterrupted duty
415V AC rated voltage

400A Fuse Switch Incoming


Devices
400A incoming devices for LF1F4A
enclosure
Standard cable termination 300mm2

Incoming
device type

Current
rating (A)

No. of poles

Max cable
termination
(mm2)

Cat. no.

L frame fuse switch


L frame fuse switch

400
400

TP&N
4

300
300

SL3P400N
SL4P400

630A/800A Fuse Switch Incoming Devices


630A/800A incoming devices for LF1F8A enclosure
Standard cable termination 630mm2

Incoming
device type

N
N
N
N

48

frame
frame
frame
frame

fuse
fuse
fuse
fuse

switch
switch
switch
switch

Current
rating
(A)

No. of
poles

Max cable
termination
(mm2)

Cat. no.

Cable
terminals

630
800
630
800

TP&N
TP&N
4
4

630
630
630
630

SN3P630N
SN3P800N
SN4P630
SN4P800

SNCET
SNCET
SNCET
SNCET

Loadbank 200
Outgoing Devices
63/125A Skeleton Switches
Exceeds the requirements of
EN 60947-3
80kA rms fused short-circuit capacity

AC23A utilisation category


Full uninterrupted duty
415V AC rated voltage

Current rating (A)

1-pole+N cat. no.

3-pole+N cat. no.

4-pole cat. no.

63
100
125

SF3P63N
SF3P100N
SF3P125N

SF4P63
SF4P100
SF4P125

160/200A Skeleton Switches


Exceeds the requirements of
EN 60947-3
80kA rms fused short-circuit capacity

AC23A utilisation category


Full uninterrupted duty
415V AC rated voltage

Current rating (A)

1-pole+N cat. no.

3-pole+N cat. no.

4-pole cat. no.

160
200

SF3P160N
SF3P200N

SF4P160
SF4P200

Loadbank 200
Outgoing Devices Accessories
Accessories for Outgoing/Incoming Skeleton Switches
Description

Current rating (A)

Picture

Cat. no.

Solid links (set of 1)


Solid links (set of 1)

63
100/200

1
1

HFL63
HFL200A

2-bank auxiliary switch


4-bank auxiliary switch

63/200
63/200

2
2

SAUX2F
SAUX4F

Terminal shrouds and barriers

63/200

SFTSS

Terminal barriers (set of 3)


Cable extension terminals
(set of 8)
Solid links (set of 1)
Solid links (set of 1)

63/200
630/800

SFTB
SNCET

400
630/800

1
1

HLL400
HNL800

2-bank auxiliary switch


4-bank auxiliary switch
6-bank auxiliary switch

400/630/800
400/630/800
400/630/800

2
2
2

SAUX2N
SAUX4N
SAUX6N

Terminal shrouds and barriers


Terminal shrouds and barriers

400
630/800

SLTS
SNTS

Terminal barriers (set of 3)


Terminal barriers (set of 3)

400
630/800

SLTB
Supplied

49

Loadbank 200
Add-on Enclosures
General Purpose Enclosures
IP4X Ingress Protection
Enclosures are 750mm wide x 200 deep
No top or bottom plates supplied (supplied with panel board)

Description
General
General
General
General
General
General

purpose
purpose
purpose
purpose
purpose
purpose

enclosure
enclosure
enclosure
enclosure
enclosure
enclosure

Modular height

Height (mm)

Cat. no.

1
2
3
4
5
6

152
305
457
609
762
914

LEBM1
LEBM2
LEBM3
LEBM4
LEBM5
LEBM6

Cableway Extension Enclosures

IP4X Ingress Protection


Recommend for cables above 70mm2
250mm wide x 200mm deep
No side plates supplied (supplied with panel board)

Description

Modular height

Height (mm)

Cat. no.

Cableway
Cableway
Cableway
Cableway
Cableway
Cableway
Cableway

1
2
3
4
5
6
8

152
305
457
609
762
914
1219

LECM1
LECM2
LECM3
LECM4
LECM5
LECM6
LECM8

MCB Distribution Board and Service Centre


IP3X (IP4X with door fitted) Ingress Protection
MCB distribution boards have fully shielded busbars and interconnections
Space saving twin option TP&N distribution board option

Description

Modular
height

Height
(mm)

Cat. no.

Door kit
cat. no.

17 MCB way SP&N distribution board


6 TP way TP&N distribution board
12 TP way TP&N distribution board
2 x 12 TP way TP&N distribution board
24 way modular service centre

1
2
3
4
1

152
305
457
609
152

LDS17
LDT106X
LDT112X
LDT212X*
LDS24

LD1DS
LD1D06X
LD1D12X
LD2D12X
LD1DS

*Only double module RCBOs can be fitted in this enclosure.

Transient Voltage Surge Protector Cableway Mounting Kits


1

Easily installed within a standard cableway (2 modules onward)


DIN-rail mounting for triple-pole MCB
C/W 30Ka three-phase surge protector
Remote status indication
Site fault indication

Description

50

Cableway mounting frame c/w surge protector


& remote indicator (1)
2 module enclosure c/w surge protector
& remote indicator (2)

Height (mm) Cat. no.

304

LECK2SM

304

LECK2SP

Loadbank 200
Metering Accessories
For easy selection of metering please refer to the charts on pages 56.

Cableway Metering Door Kits


Incoming and outgoing metering utilises cableway extension boxes
Metering door kits are available sized to the cableway extension boxes and are
designed for panel mounted meters
Includes DIN-rail for facility to mount current transformers and fuses

Description

Height

Cat. no.

2 module metering door kit, excluding CTs and control wiring


3 module metering door kit, excluding CTs and control wiring
4 module metering door kit, excluding CTs and control wiring
5 module metering door kit, excluding CTs and control wiring
6 module metering door kit, excluding CTs and control wiring
8 module metering door kit, excluding CTs and control wiring

2
3
4
5
6
8

LECMD2
LECMD3
LECMD4
LECMD5
LECMD6
LECMD8

Metering
Description

Cat. no.

Digital multi-function meter with one pulse output


Digital multi-function meter with one pulse output and
one RS485 output
Digital kilowatt hour meter with pulse output
Digital multi-function meter with pulse output
Pulse Output for Ci meter
RS485 Modbus Output for Ci meter

INT-1630-M-5-M-100
INT-1630-M-5-M-110
CI1-01-PUL
CI3-01-PUL
CI-PUL-01
CI-MOD-01

Incoming Current Transformers


Description

Max cable size mm2

Cat. no.

400A current transformer (sold singular)


600A current transformer (sold singular)
800A current transformer (sold singular)

185*/240**
185*/240**
240

M63N-400/5
M63N-600/5
M93L-800/5

Description

Max cable size mm2

Cat. no.

100A 3-in-1 CT Case size 35mm


125A 3-in-1 CT Case size 35mm
200A 3-in-1 CT Case size 35mm
250A 3-in-1 CT Case size 35mm

95*/150**
95*/150**
95*/150**
95*/150**

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

Outgoing Current Transformers

*Using standard lugs


**Using reduced palm width lugs

Metering Harnesses
Description

Cat. no.

Incoming meter loom


Voltage tap off loom for outgoing metering
CT harness for 1 outgoing meters
Power loom for 6 outgoing meters

LBWI
LBWP
LBWCT
LBWM6

51

Loadbank 200 Selection Chart - Enclosures


800A Panel Boards - Form 2
Outgoing device

Outgoing ways

Height (mm)

Weight (kg)

Cat. no.

Fuse switch
Fuse switch

6
10

5 modules
8 modules

59
98

LF806A
LF810A

800A Panel Boards - Form 4 Conversion

Cat. no.

Form 4 shields for outgoing cables up to 70mm2


Form 4 shields for outgoing cables up to 150mm2
Vertical connection kit for 800A panelboard
Blank cover plate for fuse switch handle

LFS41A
LFS42A
LCFVK
LFXHBA

Incoming Units
Device type
housing

Current
rating (A)

Height

Weight (kg)

Cat. no.

Fuse switch
Fuse switch

400
630/800

5 modules
6 modules

48.5
66.5

LF1F4A
LF1F8A

Cableways
Height

Weight (kg)

Cat. no.

1 module
2 modules
3 modules
4 modules
5 modules
6 modules
8 modules

2
4
6
8
8
12
14

LECM1
LECM2
LECM3
LECM4
LECM5
LECM6
LECM8

Surge Protection Cableway Mounting Kits


Description

Height (mm)

Cat. no.

Cableway mounting frame c/w surge protector & remote indicator


2 module enclosure c/w surge protector & remote indicator

304
304

LECK2SM
LECK2SP

General Purpose Enclosures


Height

Weight (kg)

Cat. no.

1 module
2 modules
3 modules
4 modules
5 modules
6 modules

4
10
16
22
28
34

LEBM1
LEBM2
LEBM3
LEBM4
LEBM5
LEBM6

Service Centres
Type

Outgoing ways

Height

Weight (kg)

Cat. no.

Door kit

Service centre (DIN units)

24 DIN

1 module

10

LDS24

LD1DS

MCB Distribution Boards


SP&N
Outgoing ways

Height

Weight (kg)

Enclosure cat. no.

Door kit cat. no.

17

1 module

15

LDS17

LD1DS

TP&N
Outgoing ways

Height

Weight (kg)

Enclosure cat. no.

Door kit cat. no.

6
12
2x12

2 modules
3 modules
4 modules

LDT106X
LDT112X
LDT212X

LD1D06X
LD1D12X
LD2D12X

52

23
30
35

Loadbank 200 Selection Chart - Incoming


Devices and Accessories
Loadbank 200 Incoming Devices
Fuse Switches
Device type

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

Skeleton
Skeleton
Skeleton
Skeleton

200
400
630
800

SF3P200N
SL3P400N
SN3P630N
SN3P800N

SF4P200
SL4P400
SN4P630
SN4P800

Description

Current rating (A)

Picture

Cat. no.

Cable extension terminals (set of 8)

630/800

SNCET

Solid links (set of 1)


Solid links (set of 1)

400
630/800

1
1

HLL400
HNL800

2-bank auxiliary switch


4-bank auxiliary switch
6-bank auxiliary switch

400/630/800
400/630/800
400/630/800

2
2
2

SAUX2N
SAUX4N
SAUX6N

Terminal shrouds and barriers


Terminal shrouds and barriers

400
630/800

SLTS
SNTS

Terminal barriers (set of 3)


Terminal barriers (set of 3)

400
630/800

SLTB
Supplied

switch
switch
switch
switch

Accessories for Incoming Skeleton Switches

Metering
Description

Height
(modules)

Height
(mm)

Current rating
(A)

Cable size
(mm)

Cat. no.

Metering door kit


Metering door kit
Metering door kit
Metering door kit
Metering door kit
Metering door kit
Incoming meter loom
Voltage tap off for outgoing meter
CT harness for 1 outgoing meter
Meter power loom for 1 outgoing meter
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
Current transformer
Current transformer
Current transformer
1-phase/3phase kWh meter with pulse
1-phase/3phase MF meter with pulse
1-phase/3phase MF meter with pulse and Modbus
1-phase/3phase MF meter with pulse
Optional pulse plug in module for Ci meter
Optional RS485 Modbus plug in module
for Ci meter

2
3
4
5
6
8
-

304
456
608
760
912
1216
-

100
125
150
200
250
-

95
95
95
95
95
185
185
240
-

LECMD2
LECMD3
LECMD4
LECMD5
LECMD6
LECMD8
LBWI
LBWP
LBWCT
LBWM6
M3N1-35-100/5
M3N1-35-125/5
M3N1-35-150/5
M3N1-35-200/5
M3N1-35-250/5
M63N-400/5
M63N-600/5
M93L-800/5
CI1-01-PUL
INT-1630-M-5-M-100
INT-1630-M-5-M-110
CI3-01-PUL
CI-PUL-01
CI-MOD-01

53

Loadbank 200 Selection Chart - Outgoing Fuse


Switches and Accessories
800A Panelboard
Description

Cat. no.

Vertical connection kit


Blank cover plate for fuse switch handle

LCFVK
LFXHBA

Main Enclosures - Insulation & Plates


Horizontal insulation kit
Steel end plate

MXEPF
LGES

Door Locking
Door lock/key kit
Padlocking kit for door kits

DBXCL
DBXPL

Outgoing Fuse Switches


Device

Current rating (A)

1-pole+N cat.no.

3-pole+N cat. no.

4-pole cat. no.

Skeleton
Skeleton
Skeleton
Skeleton
Skeleton

63
100
125
160
200

SF1P100N
-

SF3P63N
SF3P100N
SF3P125N
SF3P160N
SF3P200N

SF4P63
SF4P100
SF4P125
SF4P160
SF4P200

Accessories
Description

Current rating (A)

Cat. no.

Solid links (set of 1)


Solid links (set of 1)

63
100/200

HFL63
HFL200A

2-bank auxiliary switch


4-bank auxiliary switch

63/200
63/200

SAUX2F
SAUX4F

Terminal shrouds and barriers

63/200

SFTSS

Terminal barriers (set of 3)

63/200

SFTB

54

switch
switch
switch
switch
switch

Loadbank 200
Dimensions and Outline Drawings
LF810A
8 modules

LF806A
5 modules

LF1F8A
6 modules

LF1F4A
5 modules

200mm
10/6 Outgoing Ways 200A Max.
98kg
59kg

LEBM6
6 modules

200mm

34kg

LEBM5
5 modules

28kg

LEBM4
4 modules

22kg

LECM8
8 modules
LECM6
6
LECM5
5
LECM4
LECM3
4
3
LECM2
2
LECM1
1

630A/800A Switch
66.5kg*

LEBM3
3 modules

16kg

LEBM2
2 modules

10kg

Cableway
250mm

400A Switch
48.5kg*

LEBM1
1 module

4kg

Main Enclosure
750mm
8 Module Height-1219mm
6 Module Height-914mm
5 Module Height-762mm
4 Module Height-609mm
3 Module Height-457mm
2 Module Height-304mm

Standard Cableways
14kg 12kg 10kg 8kg 6kg 4kg 2kg

1 Module Height-152mm
Depth of all enclosures200mm

55

Loadbank 200 Metering Selection

Loadbank 200
The Loadbank 200 metering facilities utilise
standard cableway extension enclosures with
optional door kits designed for panel mounted
meters. The size of the cableway will determine the
corresponding metering door kit. Where cable sizes
exceed 70mm a recommendation would be to
include two cableway extension enclosures to
facilitate easy wiring. The same could be advised
when fully populating an 18 way panel board with
meters. Current transformers and fuses can be DINrail mounted within the cableways using the
facilities provided within the optional door kits.

LF806A
LF810A

Cableway Door

LF806A:-LECMD5 x 2
LF810A:-LECMD8 x 2

Panel-board enclosures
Description

Cat. no.

800A, 6 way, Form 4


800A, 10 way, Form 4

LF806A
LF806A

Description

Cat. no.

2 module metering mounting kit,


(2 meter positions)
3 module metering mounting kit,
(3 meter positions)
4 module metering mounting kit,
(4 meter positions)
5 module metering mounting kit,
(6 meter positions)
6 module metering mounting kit,
(6 meter positions)
8 module metering mounting kit,
(9 meter positions)

Incoming Meter
Arrangement

LBWP 1 Off

LBWP 1 Off

LBWP 1 Off

LECMD4
LECMD5
LBWI 1 Off

LECMD6
LECMD8

3-in-1 100A current transformers


3-in-1 125A current transformers
3-in-1 200A current transformers
3-in-1 250A current transformers
400A current transformer
(sold singular)
630A current transformer
(sold singular)
800A current transformer
(sold singular)

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

56

Right Side Outgoing


Meter Arrangement

LECMD3

Cat. no.

Digital multi-function meter


with one pulse outputs
Digital multi-function meter
with one pulse output and
one RS485 output
Digital kilowatt hour meter
with one pulse output
Digital multi-function meter
with one pulse output

Left Side Outgoing


Meter Arrangement

LECMD2

Description

Description

LF1F4A:-LECMD5 x 1
LF1F8A:-LECMD6 x 1

Up to 6 Meters:
LBWM6 1 Off

Up to 6 Meters:
LBWM6 1 Off

Above 6 Meters:
LBWM6 2 Off

Above 6 Meters:
LBWM6 2 Off

CI1-01-PUL
CI3-01-PUL
INT-1630-M-5-M-***

CI1-01-PUL
CI3-01-PUL
INT-1630-M-5-M-***

LBWCT 1 per
Meter

LBWCT 1 per
Meter

CI3-01
CI1-01
INT-1630-M-5-M-***

M63N-400/5D
M63N-600/5D
M93L-800/5D

Cat. no.
INT-1630-M-5-M-100

INT-1630-M-5-M-110
CI1-01-PUL
CI3-01-PUL

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

M53J-200/5D
3 per Meter
M53J-250/5D
3 per Meter
M63N-400/5D
3 per Meter
M63N-600/5D
3 per Meter
M63N-800/5D
3 per Meter
M93L-600/5D
3 per Meter
M93L-800/5D
3 per Meter

Section

MCCB Panel Boards


Loadbank 250 Range (400A and 800A Ratings)

Overview
Key Features
ASTA certified busbars with a
short-circuit withstand rating of
36kA for 1 second (400A)
ASTA certified busbars with a
short-circuit rating of 50kA for
1 second (800A)
Allows mounting of YA3, Y5, Y6
or Y7 MCCBs and switch
disconnectors
Single frame size for outgoing
16A to 250A MCCBs
Generous cable-spreading
space for incoming and
outgoing cables
Common width (750mm) and
depth (200mm) for all
enclosures

Loadbank 250 modular enclosure system is engineered


to provide unrivalled flexibility and build simplicity
needed to produce a wide range of power distribution
solutions. TP&N busbars of 400A and 800A comprising
of three sizes of 6, 12, 18 TP outgoing ways allow
installers to cover a multitude of commercial and
industrial applications.
Featuring circuit breakers from 16A to 400A to be
fitted as outgoing circuits, integral MCB distribution
boards, contactors, timers complemented by a new
range of incoming and outgoing metering facilities
completes the Loadbank 250 panel board range.

Available Options
400A and 800A panel boards
with 6, 12 or 18 triple-pole
outgoing ways with Y6/Y7 or
YA3 incoming devices, with
Form 3 separation
800A panel boards with 6 or 10
TP&N or four-pole outgoing
ways with fuse switch/MCCB
incomer, with Form 4
separation
Panel build options include:

Range of MCB
distribution boards
General purpose
enclosures with uncut
front plates
Metering housings and
service centres
Current transformers
Cableway enclosures

Compliance
Panel boards
MCCBs
MCBs
RCCBs
RCBOs
Skeleton Switches

58

EN 61439-2
EN 60947-2
EN 60898
EN 61008
EN 61009
60947-3

Loadbank 250 panel boards house the incomer and


outgoing units in separate, adjoining enclosures to
allow the widest range of possible circuit permutations,
including oversized outgoing circuits, to be
accommodated within a common format. The standard
finish is epoxy powder coating in light grey RAL 7035.
Loadbank 250 single module is 152mm high.

MCCB Panel Boards (400A and 800A Rating)

MCCB Panel Boards

Service centres
Cableway extension chambers
General purpose enclosures
TP&N distribution boards

Incoming Devices
Switch disconnector
Moulded case circuit breakers
Fuse combination units

Circuit Protection Devices


Moulded case circuit breakers (upto 250A
or 400A max)

Modular Devices
Surge protection
Meters, current transformers and
wiring looms
Contactors
Timer
Earth leakage device

59

Loadbank 250
250A/400A Panel Board Form 3 36kA-1sec
400A Panel Board Enclosures
Form 3 as standard
Incoming enclosures and devices to be ordered separately
ASTA certified busbars rated at 36kA-1sec
No of TP
outgoing ways

Modular
height

Height
(mm)

Width
(mm)

Depth
(mm)

Cat. no.

Door kit
cat. no.

6
12
18

4
6
8

609
914
1219

750
750
750

200
200
200

LB406YA3
LB412YA3
LB418YA3

LBDD06
LBDD12
LBDD18

400A Panel Board Accessories

Fitted with incoming housing


and metering

Description

Cat. no.

Door cylinder lock


Door padlock device
3-pole blanking piece
Steel end plate
Panel board stacking kit
Busbar extension terminals with shields to connect
to top of panel board

DBXCL
DBXPL
LBBP3PYA3
LGES
LBCK4
LBSKE

250A/400A Add-on Incoming Enclosures


Supplied with all necessary connections
Incoming devices to be ordered separately
Current rating

Device type

Modular
height

Height Cat.
(mm) no.

Neutral
link

250
400
400
200
400

YA3 MCCB
Y6 MCCB
Direct connection
F frame fuse switch
L frame fuse switch

3
5
2
3
5

457
762
305
457
762

YA3NL
Standard
Standard
Standard
Standard

LB1YA3
LB1Y6
LBDR4
LB1F2A
LB1F4A

250A Max Incoming Devices

Up to 250A Incoming devices for LB1YA3


Standard cable termination 95mm2
Maximum cable termination is 150mm2 using reduced palm width M8 cable lugs
MCCBs have thermal and magnetic overloads except switch disconnector

Incoming device type

Current rating (A)

No. of poles

Cat. no.

Switch disconnector
MCCB
MCCB
MCCB
Switch disconnector
MCCB
MCCB
MCCB

250
160
200
250
250
160
200
250

3
3
3
3
4
4
4
4

YA3B3P250D
YA3N3P160T
YA3N3P200T
YA3N3P250T
YA3B4P250D
YA3N4P160T
YA3N4P200T
YA3N4P250T

400A Incoming Devices


400A Incoming devices for LB1Y6
Standard cable termination 240mm2
Incoming device type

Current rating (A)

No. of poles

Cat. no.

Switch disconnector
MCCB
Switch disconnector
MCCB

400
400
400
400

3
3
4
4

Y6B3P400D
Y6H3P400T5
Y6B4P400D
Y6H4P400T5

200/400 Fuse Switch Devices


200A Incoming devices for LB1F2A
400A Incoming devices for LB1F4A

60

Incoming device type

Current rating (A)

No. of poles

Cat. no.

F frame fuse switch ex fuses


F frame fuse switch ex fuses
L frame fuse switch ex fuses
L frame fuse switch ex fuses

200A
200A
400A
400A

3
4
3
4

SF3P200N
SF4P200
SL3P400N
SL4P400

Loadbank 250
800A Panel Board Form 3 50kA-1sec
800A Panel Board Enclosures
Form 3 as standard
Incoming enclosures and devices to be ordered separately
ASTA certified busbars rated at 50kA-1sec

No of TP
outgoing ways

Modular
Height
height (mm) (mm)

Width
(mm)

Depth
(mm)

Cat. no.

Door kit
cat. no.

6
12
18

4
6
8

750
750
750

200
200
200

LB806YA3
LB812YA3
LB818YA3

LBDD06
LBDD12
LBDD18

609
914
1219

800A Panel Board Accessories


Description

Cat. no.

Door cylinder lock


Door padlock device
3-pole blanking piece
Panel board stacking kit
Busbar extension terminals with shields to connect
to top of panel board
Steel end plate
Horizontal insulation kit

DBXCL
DBXPL
LBBP3PYA3
LBCK8
LBSKE
LGES
MXEPF

400A/800A Add-on Incoming Enclosures


Supplied with all necessary connections
Incoming devices to be order separately

Current rating

Device type

Modular
height

Height Cat. no. Neutral


(mm)
link

800A Panel boards


400/630A
800A
800A

Y6 MCCB
Direct connection
Y7 MCCB

5
3
6

762
457
912

LB1Y6
LBDR8
LB1Y7

Standard
Standard
Standard

630A Incoming Devices


630A Incoming devices for LB1Y6
Standard cable termination 240mm2
Upto 250A or 400A
Incoming
device type

Current rating
(A)

No. of poles

Cat. no.

Switch disconnector
MCCB
Switch disconnector
MCCB

630
630
630
630

3
3
4
4

Y6B3P630D
Y6H3P630T5
Y6B4P630D
Y6H4P630T5

800A Incoming Devices


800A Incoming devices for LB1Y7
Standard cable termination 300mm2
LB1Y7 Neutral link supplied

Incoming
device type

Current rating
(A)

No. of poles

Cat. no.

Switch disconnector
MCCB
Switch disconnector
MCCB

800
800
800
800

3
3
4
4

Y7B3P800D
Y7J3P1000E*
Y7B4P800D
Y7J4P1000E*

* MCCB must be set for 800A maximum.

61

Loadbank 250
400A and 800A, Form 3 Outgoing Devices and Accessories
Outgoing YA3 MCCB Devices

Standard cable termination 95mm2


Maximum cable termination is 150mm2 using reduced palm width M8 cable lugs
Triple-pole MCCBs have thermal and magnetic overloads
Single-pole MCCBs have fixed thermal and magnetic overloads

Device
type

Current
rating
(A)

1-pole
cat. no.
(fixed
overloads)

3-pole, 25kA
cat. no.
(adjustable
overloads)

3-pole, 36kA
cat. no.
(adjustable
overloads)

3-pole, 65kA
cat. no.
(adjustable
overloads)

YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3

16
20
32
40
50
63
80
100
125
160
200
250

YA3N1P16T
YA3N1P20T
YA3N1P32T
YA3N1P40T
YA3N1P50T
YA3N1P63T
YA3N1P80T
YA3N1P100T
YA3N1P125T
YA3N1P125T
-

YA3N3P20T
YA3N3P32T
YA3N3P50T
YA3N3P63T
YA3N3P100T
YA3N3P125T
YA3N3P160T
YA3N3P200T
YA3N3P250T

YA3S3P20T
YA3S3P32T
YA3S3P50T
YA3S3P63T
YA3S3P100T
YA3S3P125T
YA3S3P160T
YA3S3P200T
YA3S3P250T

YA3J3P20T
YA3J3P32T
YA3J3P50T
YA3J3P63T
YA3J3P100T
YA3J3P125T
YA3J3P160T
YA3J3P200T
YA3J3P250T

frame
frame
frame
frame
frame
frame
frame
frame
frame
frame
frame
frame

Outgoing YA5 MCCB Devices

Standard cable termination 95mm2


Maximum cable termination 185mm2 using reduced palm width M8 cable lugs
MCCBs have adjustable overloads
For use with LB802YA5 (twin YA5 outgoing housing - page 66)

Device type

Current rating (A)

25kA cat. no.

50kA cat. no.

YA5 Frame

160A-250A

YA5N3P250T

YA5H3P250T

YA5 Frame

250A-400A

YA5N3P400T

YA5H3P400T

YA3 and YA5 MCCB Accessories


Description

Cat. no.
2

YA3 3P cable clamps (35-120mm )


YA3 4P cable clamps (35-120mm2)
YA5 3P cable clamps (95-240mm2)
YA5 4P cable clamps (95-240mm2)
Dolly locking device
100-120V AC shunt trip
200-240V AC shunt trip
380-450V AC shunt trip
24V DC shunt trip
100-120V AC under-voltage release
200-240V AC under-voltage release
380-450V AC under-voltage release
24V DC under-voltage release
YA3 3P terminal shield
YA3 4P terminal shield
YA5 3P terminal shield
YA5 4P terminal shield

62

YA3CC3P
YA3CC4P
YA5CC3P
YA5CC4P
YADL1
YAST115AC
YAST240AC
YAST450AC
YAST24DC
YAUVR120AC
YAUVR240AC
YAUVR450AC
YAUVR24DC
YA3TS3P
YA3TS4P
YA5TS3P
YA5TS4P

Loadbank 250
800A Form 4 MCCB Panel Board
The Form 4 panel board range features a 800A TP&N
four-pole busbar assembly comprises of two stackable
designs of 6 and 10 TP&N ways. Three incoming
enclosures are available with MCCB or fuse switch
incoming options offering a cost effective, off the shelf
solution for projects which require Form 4 separation.
A comprehensive range of general purpose add-on
units and cableways with metering options complete
this versatile range.

Features
Exceeds EN60439-1
ASTA certified busbars with a
short-circuit withstand rating of
50kA-1sec
Form 3 as standard
Form 4 with Form 4 shielding
fitted
IP4X Ingress Protection
Single frame size outgoing
triple-pole MCCBs from 16A-250A
Common width (750mm) and
depth (200mm) for all enclosures
Fully rated neutrals
Does not accept 1-pole outgoing
devices

63

Loadbank 250
800A Panel Board Form 4 50kA-1sec
800A Panel Boards - Form 4

No provision for 1-pole MCCBs


Form 3 as standard
Form 4 with optional shielding
IP3X (IP4X with door kit fitted) Ingress Protection
750mm wide x 200mm deep
Spare busbar terminal covers/blanking plates are to be ordered separately

No of TP
outgoing ways

Modular
height

Height
(mm)

Weight
(kg)

Cat. no.

Optional
door kit

6
10

5
8

760
1216

59
98

LF806YA
LF810YA

MXD06
MXD10

800A Panel Board Accessories


Description

Cat. no.

Form 4 shielding for cable up to 70mm2


Form 4 shielding for outgoing cables to 150mm2
Vertical stacking connection kit
Blanking plate for unused way

LFS41YA
LFS42YA
LCFVK
YA3F4BP

Add-on Incoming Enclosures


Form 4 as standard
IP4X Ingress Protection

Current
rating
(A)

Modular
height

Height
(mm)

Weight
(kg)

Device
type

Cat. no.

Connection
kit required

400

762

98

LF1F4A

630/800 8

1216

66.5

LF1F8A

400-800 5

762

45.2

L frame fuse
switch
N frame fuse
switch
Y6 MCCB/
MCCB switch
disconnector

MMS15Y*

MCFMY6

*Neutral link supplied

400A Fuse Switch Incoming Devices


400A Incoming devices for LF1F4A enclosure
Standard cable termination 240mm2

64

Incoming device type

Current rating (A)

No. of poles

Cat. no.

L frame fuse switch


L frame fuse switch

400
400

TP&N
4

SL3P400N
SL4P400N

Loadbank 250
800A Panel Board Incoming and Outgoing Devices
630A/800A Fuse Switch Incoming Devices
630A/800A Incoming devices for LF1F8A enclosure
Standard cable termination 630mm2

Incoming
device type

N
N
N
N

frame
frame
frame
frame

fuse
fuse
fuse
fuse

switch
switch
switch
switch

Current
rating
(A)

No. of
poles

Max cable
termination
(mm2)

Cat. no.

Cable
terminals

630
800
630
800

TP&N
TP&N
4
4

630
630
630
630

SN3P630N
SN3P800N
SN4P630N
SN4P800N

SNCET
SNCET
SNCET
SNCET

Incoming MCCB Devices


400A-800A Incoming devices for MMS15Y enclosure
Standard cable termination 240mm2
Triple-pole and four-pole MCCBs have adjustable thermal and magnetic
overloads

Incoming
device type

Y6
Y6
Y6
Y6
Y6
Y6
Y6
Y6

Current
rating (A)

frame switch disconnector 400


frame MCCB
400
frame MCCB
630
frame MCCB
800
frame switch disconnector 400
frame MCCB
400
frame MCCB
630
frame MCCB
800

No. of
poles

Max cable
termination
(mm2)

Cat. no.

3
3
3
3
4
4
4
4

240
240
240
240
240
240
240
240

Y6B3P400D
Y6H3P400T5
Y6H3P630T5
Y6H3P800T5
Y6B4P400D
Y6H4P400T5
Y6H4P630T5
Y6H4P800T5

Outgoing MCCB Devices


Standard cable termination 95mm2
Maximum cable termination is 150mm2 using reduced palm width M8 cable lugs
Triple-pole MCCBs have adjustable thermal and magnetic overloads

Device type

Current
rating (A)

3-pole, 25kA
cat. no.
(adjustable
overloads)

3-pole, 36kA
cat. no.
(adjustable
overloads)

3-pole, 65kA
cat. no.
(adjustable
overloads)

YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3
YA3

16
20
32
40
50
63
80
100
125
160
200
250

YA3N3P20T
YA3N3P32T
YA3N3P50T
YA3N3P63T
YA3N3P100T
YA3N3P125T
YA3N3P160T
YA3N3P200T
YA3N3P250T

YA3S3P20T
YA3S3P32T
YA3S3P50T
YA3S3P63T
YA3S3P100T
YA3S3P125T
YA3S3P160T
YA3S3P200T
YA3S3P250T

YA3J3P20T
YA3J3P32T
YA3J3P50T
YA3J3P63T
YA3J3P100T
YA3J3P125T
YA3J3P160T
YA3J3P200T
YA3J3P250T

frame
frame
frame
frame
frame
frame
frame
frame
frame
frame
frame
frame

65

Loadbank 250
400A and 800A, Form 3 and 4, Panel Board Add-on Enclosures
General Purpose Enclosures
IP4X Ingress Protection
Enclosures are 750mm wide x 200 deep
No top or bottom plates supplied (supplied with panel board)

Description
General
General
General
General
General
General

purpose
purpose
purpose
purpose
purpose
purpose

enclosure
enclosure
enclosure
enclosure
enclosure
enclosure

Modular height

Height (mm)

Cat. no.

1
2
3
4
5
6

152
305
457
609
762
914

LEBM1
LEBM2
LEBM3
LEBM4
LEBM5
LEBM6

Cableway Extension Enclosures

IP4X Ingress Protection


Recommend for cables above 70mm2
250mm wide x 200mm deep
No side plates supplied (supplied with panel board)

Description

Modular height

Height (mm)

Cat. no.

Cableway
Cableway
Cableway
Cableway
Cableway
Cableway
Cableway

1
2
3
4
5
6
8

152
305
457
609
762
914
1219

LECM1
LECM2
LECM3
LECM4
LECM5
LECM6
LECM8

MCB Distribution Board and Service Centre


IP3X (IP4X with door fitted) Ingress Protection
MCB distribution boards have fully shielded busbars and interconnections
Space saving twin option TP&N distribution board option

Description

Modular
height

Height
(mm)

Cat. no.

Door kit
cat. no.

17 MCB way SP&N distribution board


6 TP way TP&N distribution board
12 TP way TP&N distribution board
2 x 12 TP way TP&N distribution board
24 way modular service centre

1
2
3
4
1

152
305
457
609
152

LDS17
LDT106X
LDT112X
LDT212X*
LDS24

LD1DS
LD1D06X
LD1D12X
LD2D12X
LD1DS

*Only double module RCBOs can be fitted in this enclosure.

Twin YA5 Outgoing Housing (not design for use with Form 4 panel
boards)
Can be mounted direct to incoming enclosure without connection kit
When mounting to 800A panelboard connection kits are required
(LBSKE and LBCK8)
Cableway extension enclosures are necessary to assist with cabling
Terminal shields required per MCCB (YA5TC3P)
Devices to be ordered separately (page 62)
Description

Modular
height

Height
(mm)

Twin YA5 (400A max each) 3 modules 456

66

Weight Cat. no.


(kg)
35

Door kit
cat. no.

LB802YA5 LBDD02

Loadbank 250
400A and 800A, Form 3 and 4, Panel Board Metering Accessories
For easy selection of metering please refer to the chart on pages 80.

Cableway Metering Door Kits


Incoming and outgoing metering utilises cableway extension boxes
Metering door kits are available sized to the cableway extension boxes and are
designed for panel mounted meters
Includes DIN-rail for facility to mount current transformers and fuses
Description

Height

Cat. no

2 module metering door kit, excluding CTs and control wiring


3 module metering door kit, excluding CTs and control wiring
4 module metering door kit, excluding CTs and control wiring
5 module metering door kit, excluding CTs and control wiring
6 module metering door kit, excluding CTs and control wiring
8 module metering door kit, excluding CTs and control wiring

2
3
4
5
6
8

LECMD2
LECMD3
LECMD4
LECMD5
LECMD6
LECMD8

Panel Mounted Meters for Incoming Circuits

93mm x 96mm dimensions


Low profile
Fully progammable CT ratios
Can be configured SP or TP

Device type

Outputs

Width (mm) Cat. no.

1-phase/3-phase digital kWh meter


1-phase/3-phase digital
multi-function meter
1-phase/3-phase digital
multi-function meter
1-phase/3-phase digital
multi-function meter
Optional pulse plug-in module
for Ci1 meter
Optional RS485 Modbus plug-in
module for Ci meter

1 pulse
1 pulse

96
96

CI1-01-PUL
INT-1630-M-5-M-100

1 pulse &
1 Modbus
1 pulse

96

INT-1630-M-5-110

96

CI3-01-PUL

CI-PUL

CI-MOD-01

Surge Protection Cableway Mounting Kits

Optional Modbus plug-in module for Ci meter


Easily installed within a standard cableway (2 modules onward)
DIN-rail mounting for triple-pole MCB
C/W 30Ka three-phase surge protector
Remote status indication
Site fault indication

2
Description

Height (mm) Cat. no.

Cableway mounting frame c/w surge protector


& remote indicator (1)
2 module enclosure c/w surge protector
& remote indicator (2)

304

LECK2SM

304

LECK2SP

3-in-1 Current Transformers


Description

Max cable size mm2

Cat. no.

100A current transformer (sold singular)


125A current transformer (sold singular)
200A current transformer (sold singular)
250A current transformer (sold singular)
400A current transformer (sold singular)
630A current transformer (sold singular)
800A current transformer (sold singular)

95*/150**
95*/150**
95*/150**
95*/150**
185*/240**
240
240

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5
M63N-400/5D
M63N-600/5D
M93L-800/5D

* Using standard cable lugs.


**Using reduced palm width cable lugs.

Metering Harnesses
Description

Cat. no.

Incoming meter loom


Voltage tap off loom for outgoing metering
CT harness for 1 outgoing meters
Power loom for 6 outgoing meters

LBWI
LBWP
LBWCT
LBWM6

67

Loadbank 250 Selection Chart - 400A Panel


Boards and Incomer Housings
400A Panel Boards - Form 3
ASTA busbar short circuit Outgoing
rating of 36kA for 1 second device

Outgoing
ways

Height

Weight
(kg)

Panel
cat. no.

Door kit
cat. no.

Rating
250A outgoing
250A outgoing
250A outgoing

6
12
18

4 modules
6 modules
8 modules

36
52
66

LB406YA3
LB412YA3
LB418YA3

LBDD06
LBDD12
LBDD18

MCCB/YA3
MCCB/YA3
MCCB/YA3

Incomer Housings - Form 3


Incoming device type

Current
rating (A)

Height

Weight (kg)

Cat. no.

MCCB/YA3
MCCB/Y6
Direct connection
Fuse switch
Fuse switch

250
400
400
200
400

3
5
2
3
5

26
45
18
37.5
48.5

LB1YA3
LB1Y6
LBDR4
LB1F2A
LB1F4A

Housing type

Standard
apertures

Height

Weight (kg)

Cat. no.

Cableway
Cableway
Cableway
Cableway
Cableway
Cableway
Cableway

Yes
Yes
Yes
Yes

1 module
2 modules
3 modules
4 modules
5 modules
6 modules
8 modules

2
4
6
8
8
12
14

LECM1
LECM2
LECM3
LECM4
LECM5
LECM6
LECM8

Description

Height (mm)

Cat. no.

Cableway mounting frame c/w surge protector and remote indicator


2 module enclosure c/w surge protector and remote indicator

304
304

LECK2SM
LECK2SP

modules
modules
modules
modules
modules

Cableways - Form 2/3

Yes

Surge Protection Cableway Mounting Kits

Housed Fuse Switch


Adaptor kits

Current rating (A)

Kit for HBF3P200N, incl. connections


Kit for HBF3P400N, incl. connections

Cat. no.

200
400

LBSK2B
LBSK4B

General Purpose Enclosures


Housing type
General
General
General
General
General
General

68

purpose
purpose
purpose
purpose
purpose
purpose

uncut
uncut
uncut
uncut
uncut
uncut

front
front
front
front
front
front

plate
plate
plate
plate
plate
plate

Height

Weight (kg)

Cat. no.

1 module
2 modules
3 modules
4 modules
5 modules
6 modules

4
10
16
22
28
34

LEBM1
LEBM2
LEBM3
LEBM4
LEBM5
LEBM6

Loadbank 250 Selection Chart - 400A Panel


Boards Add-on Enclosure and Accessories
Metering
Description

Height
(modules)

Height
(mm)

Current rating
(A)

Cable size
(mm)

Cat. no.

Metering door kit


Metering door kit
Metering door kit
Metering door kit
Metering door kit
Metering door kit
Incoming meter loom
Voltage tap off for outgoing meter
CT harness for 1 outgoing meter
Meter power loom for 1 outgoing meter
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
Current transformer
Current transformer
Current transformer
1-phase/3phase kWh meter with pulse
1-phase/3phase MF meter with pulse
1-phase/3phase MF meter with pulse and Modbus
1-phase/3phase MF meter with pulse
Optional pulse plug in module for Ci
Optional RS485 Modbus plug in module for Ci

2
3
4
5
6
8
-

304
456
608
760
912
1216
-

100
125
150
200
250
-

95
95
95
95
95
185
185
240
-

LECMD2
LECMD3
LECMD4
LECMD5
LECMD6
LECMD8
LBWI
LBWP
LBWCT
LBWM6
M3N1-35-100/5
M3N1-35-125/5
M3N1-35-150/5
M3N1-35-200/5
M3N1-35-250/5
M63N-400/5
M63N-600/5
M93L-800/5
CI1-01-PUL
INT-1630-M-5-M-100
INT-1630-M-5-M-110
CI3-01-PUL
CI-PUL-01
CI-MOD-01

MCB Distribution Boards


Outgoing ways
SP&N

Height

Weight
(kg)

Enclosure
cat. no.

Door kit
cat. no.

1 module

15

LDS17

LD1DS

2 modules
3 modules
4 modules

23
30
35

LDT106X
LDT112X
LDT212X

LD1D06X
LD1D12X
LD2D12X

Service Centres
Type

Height

Weight
(kg)

Cat. no.

Door kit
cat. no.

Service centre (24 DIN units)

1 module

LDS24

LD1DS

17

TP&N
6
12
2x12

10

Accessories for 400A Panel Board Systems


Description

Cat. no.

Loadbank 250/distribution boards/service centres


Blanking piece 3-pole MCCB (1 front shield blank)
Vertical connection kit (400A)
Busbar terminals - extensions with shield, to connect both ends of busbar
Adaptor kit for 200A housed fuse switch
Adaptor kit for 400A housed fuse switch
Horizontal insulation kit
Steel end plate

LBBP3PYA3
LBCK4
LBSKE
LBSK2B
LBSK4B
MXEPF
LGES

Door Locking

Cat. no.

Door lock/key kit


Padlocking kit for door kits

DBXCL
DBXPL

69

Loadbank 250 Selection Chart - 400A


Panel Board Circuit Protection Devices
Incoming Devices
Current rating (A)
Max.

3-pole cat. no.

4-pole cat. no.

Min.

YA3 switch disconnector


250

YA3B3P250D

YA3B4P250D

YA3 frame MCCB - 25kA


250

160

YA3N3P250T

YA3N4P250T

YA3 frame MCCB - 36kA


250

160

YA3S3P250T

YA3S4P250T

Y6 switch disconnector
400

Y6B3P400D

Y6B4P400D

Y6 frame MCCB - 50kA


400

250

Y6H3P400T5

Y6H4P400T5

200A skeleton switches


200

SF3P200N

SF4P200

400A skeleton switches


400

SL3P400N

SL4P400

400A direct connection


400

LBDR4

1-pole cat. no.

3-pole cat. no.

YA3 MCCB 25kA


16
20
32
40
50
63
80
100
125
160
200
250

YA3N1P16T
YA3N1P20T
YA3N1P32T
YA3N1P40T
YA3N1P50T
YA3N1P63T
YA3N1P80T
YA3N1P100T
YA3N1P125T
YA3N1P160T

YA3N3P20T
YA3N3P32T

YA3N3P50T
YA3N3P63T

YA3N3P100T
YA3N3P125T
YA3N3P160T
YA3N3P200T
YA3N3P250T

YA3 MCCB - 36kA


20
32
50
63
100
125
160
200
250

YA3S3P20T
YA3S3P32T
YA3S3P50T
YA3S3P63T
YA3S3P100T
YA3S3P125T
YA3S3P160T
YA3S3P200T
YA3S3P250T

Outgoing Devices for Form 2 Panel Boards


Current rating (A)
Max.

70

Loadbank 250 Selection Chart - 400A Panel


Board and Incoming Devices Accessories
Accessories for 400A Skeleton Switches
Description

Cat. no.

Solid links (set of 1)


Terminal barriers (set of 3)
Fuse shrouds
Terminal shrouds and barriers
2-blank auxiliary switch
4-blank auxiliary switch
6-blank auxiliary switch

HLL400
SLTB
SLFS
SLTS
SAUX2N
SAUX4N
SAUX6N

Y6 Frame Accessories
Description

Cat. no.

Terminal covers 3-pole


Interphase barriers (set of 2)

Y5TB3P

Terminal covers 4-pole


Interphase barriers (set of 3)

Y5TB4P

Terminations 4-pole
Extension terminal bars

Y6XT4P

Locking devices
Dolly padlock device

Y6DL

Shunt trips
Shunt 100-115V AC
Shunt 200-450V AC
Shunt 24V DC

Y6ST115AC
Y6ST450AC
Y6ST24DC

Under-voltage release
UVR 100-120V AC
UVR 200-240V AC
UVR 380-450V AC
UVR 24V DC

Y6UVR120AC
Y6UVR240AC
Y6UVR450AC
Y6UVR24DC

Auxiliary switches
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary

Y6AUX1
Y6AUX2
Y6AUXAL

71

Loadbank 250 Selection Chart - 400A Panel


Board Outgoing Devices Accessories
Description

Cat. no.

Terminal covers 3-pole


YA3 frame interphase barrier (set of 1) 2 required for 3-pole device
YA3 frame long terminal shroud (set of 1)
YA3 frame short terminal shroud (set of 1)

YA3TB
YA3TS3P
YA3TS3PS

Terminations 3-pole
YA3 frame cable clamps 35-120mm2 (set of 3)

YA3CC3P

Terminal covers 4-pole


YA3 frame interphase barrier (set of 1) 3 required for 3-pole device
YA3 frame long terminal shroud (set of 1)
YA3 frame short terminal shroud (set of 1)

YA3TB
YA3TS4P
YA3TS4PS

Terminations 4-pole
YA3 frame cable clamps 35-120mm2 (set of 4)

YA3CC4P

Shunt trips
YA frame shunt
YA frame shunt
YA frame shunt
YA frame shunt

YAST115AC
YAST240AC
YAST450AC
YAST24DC

trip
trip
trip
trip

100-120V AC
200-240V AC
380-450V AC
24V DC

Auxiliary and alarm switches


YA frame 1AB auxiliary switch
YA frame alarm switch
Under-voltage release
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage

release
release
release
release

YAAUX1
YAAL

100-120V AC
200-240V AC
380-450V AC
24V DC

Locking devices
YA frame dolly padlock device
YA frame Castell* (DS1) lock direct mtg. trapped on
*Castell is a trademark of Castell Safety International Limited.

72

YAUVR120AC
YAUVR240AC
YAUVR450AC
YAUVR24DC

YADL1
YACL

Loadbank 250 Selection Chart - 800A Panel


Boards and Incomer Housings
800A Panel Boards Form 3
ASTA busbar short circuit rating
of 50kA for 1 second

Outgoing
device

Outgoing
ways

250A outgoing
250A outgoing
250A outgoing

MCCB/YA3
MCCB/YA3
MCCB/YA3

6
12
18

Incomer Housings Form 3


Incomer device type

MCCB/Y6
MCCB/Y7
Direct connection

Outgoing Housings Form 3


Incomer device type

Height

Weight
(kg)

Panel
cat. no.

Door kit
cat no.

4 modules
6 modules
8 modules

42
62
78

LB806YA3
LB812YA3
LB818YA3

LBDD06
LBDD12
LBDD18

Current
rating (A)

Height

Weight
(kg)

Cat. no.

630
800
800

5 modules
6 modules
3 modules

45
69
23

LB1Y6
LB1Y7
LBDR8

Current
rating (A)

Outgoing
ways

Height

Weight
(kg)

Panel
cat. no.

Door kit
cat. no.

2x YA5 MCCB

400

3 modules

25

LB802YA5

LBDD02

800A Panel Boards Form 4


ASTA busbar short circuit rating
of 50kA for 1 second

Outgoing
device

Outgoing
ways

Height

Weight
(kg)

Panel
cat. no.

Door kit
cat no.

250A outgoing
250A outgoing

MCCB/YA3
MCCB/YA3

6
10

5 modules
8 modules

59
98

LF806YA
LF810YA

MXD06
MXD10

Incomer Housings Form 4


Device type housing

Fuse switch
Y6 frame MCCB
Y6 connection kit

Shielding Form 4
Description

70mm2 cables
150mm2 cables

Current
rating (A)

Height

Weight
(kg)

Cat. no.

630/800
800

6 modules
5 modules

67
59

LF1F8A
MMS15Y
MCFMY6

Additional
housing

Cat. no.

LFS41YA
LFS42YA

Cableway

Surge Protection Cableway Mounting Kits


Description

Height (mm)

Cat. no.

Cableway mounting frame c/w surge protector and remote indicator


2 module enclosure c/w surge protector and remote indicator

304
304

LECK2SM
LECK2SP

73

Loadbank 250 Selection Chart - 800A Panel


Boards Add-on Enclosures and Accessories
Metering
Description

Height
(modules)

Height
(mm)

Current rating
(A)

Cable size
(mm)

Cat. no.

Metering door kit


Metering door kit
Metering door kit
Metering door kit
Metering door kit
Metering door kit
Incoming meter loom
Voltage tap off for outgoing meter
CT harness for 1 outgoing meter
Meter power loom for 1 outgoing meter
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
3-in-1 current transformers
Current transformer
Current transformer
Current transformer
1-phase/3phase kWh meter with pulse output
1-phase/3phase MF meter with pulse output
1-phase/3phase MF meter with pulse
and Modbus output
1-phase/3phase MF meter with pulse output
Optional pulse plug in module for Ci meter
Optional RS485 Modbus plug in module for
Ci meter
-

2
3
4
5
6
8
-

304
456
608
760
912
1216
-

100
125
150
200
250
-

95
95
95
95
95
185
185
240
-

LECMD2
LECMD3
LECMD4
LECMD5
LECMD6
LECMD8
LBWI
LBWP
LBWCT
LBWM6
M3N1-35-100/5
M3N1-35-100/5
M3N1-35-100/5
M3N1-35-100/5
M3N1-35-100/5
M63N-400/5
M63N-600/5
M93L-800/5
CI1-01-PUL
INT-1630-M-5-M-100
INT-1630-M-5-M-110

CI3-01-PUL
CI-PUL-01
CI-MOD-01

MCB Distribution Boards


Outgoing ways
SP&N

Height

Weight
(kg)

Enclosure
cat. no.

Door kit
cat. no.

1 module

15

LDS17

LD1DS

2 modules
3 modules
4 modules

23
30
35

LDT106X
LDT112X
LDT212X

LD1D06X
LD1D12X
LD2D12X

Service Centres
Type

Height

Weight
(kg)

Cat. no.

Door kit
cat. no.

Service centre (24 DIN units)

1 module

LDS24

LD1DS

17

TP&N
6
12
2x12

10

Accessories for 400A Panel Board Systems


Description

Cat. no.

Loadbank 250/distribution boards/service centres


Blanking piece 3-pole MCCB (1 front shield blank)
Vertical connection kit (800A)
Busbar terminals - extensions with shield, to connect both ends of busbar
Adaptor kit for 200A housed fuse switch
Adaptor kit for 400A housed fuse switch
Horizontal insulation kit
Steel end plate

LBBP3PYA3
LBCK8
LBSKE
LBSK2B
LBSK4B
MXEPF
LGES

Door Locking

Cat. no.

Door lock/key kit


Padlocking kit for door kits

DBXCL
DBXPL

74

Loadbank 250 Selection Chart - 800A Panel


Boards Incoming Devices
Incoming Devices Form 3 Panel Boards
Current rating (A)
Max.
Min.

3-pole cat. no.

4-pole cat. no.

Y6 Frame Switch Disconnector


630

Y6B3P630D

Y6B4P630D

Y6 Frame MCCB Thermal/Magnetic


Icu 50 kA
630

400

Y6H3P630T5

Y6H4P630T5

Y6 Frame MCCB Electronic Icu 50kA


630

315

Y6H3P630E

Y6H4P630E

Y7 Frame Switch Disconnector


800

Y7B3P800D

Y7B4P800D*

Y7 Frame MCCB Electronic Icu 65kA


1000

500

Y7J3P1000E

Y7J4P1000E*

*This MCCB must be set at 800A maximum.

Incoming Devices Form 4 Panel Boards


Fuse Switch
Current rating (A)

3-pole+N cat. no.

4-pole+N cat. no.

630
800

SN3P630N
SN3P800N

SN4P630
SN4P800

Y6 Switch Disconnector Panel Boards


Current rating (A)

3-pole cat. no.

4-pole cat. no.

800

Y6B3P800D

Y6B4P800D

Y6H3P800T5

Y6H4P800T5

Y6H3P800E

Y6H4P800E

Y6 Frame MCCB Thermal/Magnetic


Current rating (A)
Max.

Min.

800

500

Y6 Frame MCCB Electronic


Current rating (A)
Max.

Min.

800

400

75

Loadbank 250 Selection Chart - 800A Panel


Board Incoming Accessories
630/800A Skeleton Switches Accessories
Description

Cat. no.

Cable extension terminals (set of 8)


Solid links (set of 1)
Terminal barriers (set of 3)
Fuse shrouds

SNCET
HNL800
Supplied
SNFS

Y6 Frame Accessories
Description

Cat. no.

Terminal covers 3-pole


Interphase barriers (set of 2)

Y5TB3P

Terminal covers 4-pole


Interphase barriers (set of 3)

Y5TB4P

Terminations 4-pole
Extension terminal bars

Y6XT4P

Locking devices
Dolly padlock device

Y6DL

Shunt trips
Shunt 100-120V AC
Shunt 200-450V AC
Shunt 24V DC

Y6ST115AC
Y6ST450AC
Y6ST24DC

Under-voltage release
UVR 100-120V AC
UVR 200-240V AC
UVR 380-450V AC
UVR 24V DC

Y6UVR120AC
Y6UVR240AC
Y6UVR450AC
Y6UVR24DC

Auxiliary switches
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary

Y6AUX1
Y6AUX2
Y6AUXAL

76

Loadbank 250 Selection Chart - 800A Panel


Board Incoming Device Accessories
Y7 Frame Accessories
Description

Cat. no.

Terminal covers 3-pole


Interphase barriers (set of 2)

Y5TB3P

Terminal covers 4-pole


Interphase barriers (set of 3)

Y5TB4P

Locking devices
Dolly padlock device

Y7DL

Shunt trips
Shunt 100-120V AC
Shunt 200-450V AC
Shunt 24V DC

Y7ST115AC
Y7ST450AC
Y7ST24DC

Under-voltage release
UVR 100-120V AC
UVR 200-240V AC
UVR 380-450V AC
UVR 24V DC

Y7UVR120AC
Y7UVR240AC
Y7UVR450AC
Y7UVR24DC

Auxiliary switches 3-pole MCCB


1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary

Y7AUX3P1
Y7AUX3P2
Y7AUX3PAL

Auxiliary switches 4-pole MCCB


1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary

Y7AUX4P1
Y7AUX4P2
Y7AUX4PAL

77

Loadbank 250 Selection Chart - 800A Panel


Boards Outgoing Devices
Outgoing Devices for Form 3 Panel Boards
Current rating (A)
Max.
Min.

1-pole cat. no.

3-pole cat. no.

YA3 frame MCCB - 25kA


16
20
32
40
50
63
80
100
125
160
200
250

YA3N1P16T
YA3N1P20T
YA3N1P32T
YA3N1P40T
YA3N1P50T
YA3N1P63T
YA3N1P80T
YA3N1P100T
YA3N1P125T
YA3N1P160T
-

YA3N3P20T
YA3N3P32T
YA3N3P50T
YA3N3P63T
YA3N3P100T
YA3N3P125T
YA3N3P160T
YA3N3P200T
YA3N3P250T

YA3 frame MCCB - 36kA


50
63
100
125
160
200
250

32
40
63
80
100
125
160

YA3S3P50T
YA3S3P63T
YA3S3P100T
YA3S3P125T
YA3S3P160T
YA3S3P200T
YA3S3P250T

Outgoing Devices for Form 4 Panel Boards


Current rating (A)
4-pole 25kA
Max.
Min.
cat. no.

4-pole 36kA
cat. no.

4-pole 65kA
cat. no.

YA3 frame MCCB


20
32
50
63
100
125
160
200
250

YA3S4P50T
YA3S4P63T
YA3S4P100T
YA3S4P125T
YA3S4P160T
YA3S4P200T
YA3S4P250T

YA3J4P50T
YA3J4P63T
YA3J4P100T
YA3J4P125T
YA3J4P160T
YA3J4P200T
YA3J4P250T

78

13
20
32
40
63
80
100
125
160

YA3N4P20T
YA3N4P32T
YA3N4P50T
YA3N4P63T
YA3N4P100T
YA3N4P125T
YA3N4P160T
YA3N4P200T
YA3N4P250T

Loadbank 250 Selection Chart 800A Panel


Board Outgoing Device Accessories
Description

Cat. no.

Terminal covers 3-pole


YA3 frame interphase barrier (set of 1) 2 required for 3-pole device
YA3 frame long terminal shroud (set of 1)
YA3 frame short terminal shroud (set of 1)

YA3TB
YA3TS3P
YA3TS3PS

Terminations 3-pole
YA3 frame cable clamps 35-120mm2 (set of 3)

YA3CC3P

Terminal covers 4-pole


YA3 frame interphase barrier (set of 1) 3 required for 3-pole device
YA3 frame long terminal shroud (set of 1)
YA3 frame short terminal shroud (set of 1)

YA3TB
YA3TS4P
YA3TS4PS

Terminations 4-pole
YA3 frame cable clamps 35-120mm2 (set of 4)

YA3CC4P

Shunt trips
YA frame shunt
YA frame shunt
YA frame shunt
YA frame shunt

YAST115AC
YAST240AC
YAST450AC
YAST24DC

trip
trip
trip
trip

100-120V AC
200-240V AC
380-450V AC
24V DC

Auxiliary and alarm switches


YA frame 1AB auxiliary switch
YA frame alarm switch
Under-voltage release
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage
YA frame under-voltage

release
release
release
release

YAAUX1
YAAL

100-120V AC
200-240V AC
380-450V AC
24V DC

YAUVR120AC
YAUVR240AC
YAUVR450AC
YAUVR24DC

Locking devices
YA frame dolly padlock device
YA frame Castell* (DS1) lock to be ordered separately

YADL1
YACL

Motor actuator
YA3 motor actuator AC 100-110V
YA3 motor actuator AC 230-240V

YA3MA110
YA3MA240

*Castell is a trademark of Castell Safety International Limited.

79

Loadbank 250 Meter Selection Process

Loadbank 200/250
The Loadbank 200/250 metering facilities utilise
standard cableway extension enclosures with
optional door kits designed for panel mounted
meters. The size of the cableway will determine the
corresponding metering door kit. Where cable sizes
exceed 70mm a recommendation would be to
include two cableway extension enclosures to
facilitate easy wiring. The same could be advised
when fully populating an 18 way panel board with
meters. Current transformers and fuses can be DINrail mounted within the cableways using the
facilities provided within the optional door kits.

Cat. no.

400A, 6 way, Form 3


400A, 8 way, Form 3
400A, 12 way, Form 3
800A, 6 way, Form 3
800A, 12 way, Form 3
800A, 18 way, Form 3
800A, 6 way, Form 4
800A, 10 way, Form 4

LB406YA3
LB412YA3
LB418YA3
LB806YA3
LB812YA3
LB818YA3
LF806YA
LF810YA

Description

Cat. no.

2 module metering mounting kit,


(2 meter positions)
3 module metering mounting kit,
(3 meter positions)
4 module metering mounting kit,
(4 meter positions)
5 module metering mounting kit,
(6 meter positions)
6 module metering mounting kit,
(6 meter positions)
8 module metering mounting kit,
(9 meter positions)

Description
3-in-1 100A current transformers
3-in-1 125A current transformers
3-in-1 200A current transformers
3-in-1 250A current transformers
400A current transformer
(sold singular)
630A current transformer
(sold singular)
800A current transformer
(sold singular)

LECMD2
LECMD3

LB806YA3
LB812YA3
LB818YA3
LB802YA5

LF806YA
LF810YA

LB806YA3:LECMD4 x 2
LB812YA3:LECMD6 x 2
LB818YA3:LECMD8 x 2
LB802YA5:LECMD3 x 2

LF806YA:-LECMD5 x 2
LF810YA:-LECMD8 x 2

Cableway Door
LB406YA3:LECMD4 x 2
LB412YA3:-LECMD6 x 2
LB418YA3:-LECMD8 x 2
LB1YA3:-LECMD3 x 1
LB1Y6:-LECMD5 x 1
LBDR4:-LECMD2 x 1
LB1F2A:-LECMD3 x 1
LB1F4A:-LECMD5 x 1

Panel-board enclosures
Description

LB1Y6:-LECMD5 x 1
LB1Y7:-LECMD6 x 1
LBDR8:-LECMD3 x 1

Left Side Outgoing


Meter Arrangement

Right Side Outgoing


Meter Arrangement

LBWP 1 Off

LBWP 1 Off

LF1F8A:-LECMD5 x 1
MMS15Y:-LECMD6 x 1
LF1F4A

Incoming Meter
Arrangement

LECMD4
LECMD5
LECMD6
LECMD8

LBWI 1 Off

Cat. no.

Up to 6 Meters:
LBWM6 1 Off

Up to 6 Meters:
LBWM6 1 Off

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5
M63N-400/5D

Above 6 Meters:
LBWM6 2 Off

Above 6 Meters:
LBWM6 2 Off

CI1-01-PUL
CI3-01-PUL
INT-1630-M-5-M-***

CI1-01-PUL
CI3-01-PUL
INT-1630-M-5-M-***

LBWCT 1 per
Meter

LBWCT 1 per
Meter

CI3-01
CI1-01
INT-1630-M-5-M-***

M63N-600/5D
M93L-800/5D

Description

Cat. no.

Digital multi-function meter


with one pulse outputs
Digital multi-function meter
with one pulse output and
one RS485 output
Digital kilowatt hour meter
with one pulse output
Digital multi-function meter
with one pulse output

INT-1630-M-5-M-100

80

LB406YA3
LB412YA3
LB418YA3

INT-1630-M-5-M-110

CI1-01-PUL
CI3-01-PUL

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

M3N1-35-100/5
M3N1-35-125/5
M3N1-35-200/5
M3N1-35-250/5

M53J-200/5D
3 per Meter
M53J-250/5D
3 per Meter
M63N-400/5D
3 per Meter
M63N-600/5D
3 per Meter
M63N-800/5D
3 per Meter
M93L-600/5D
3 per Meter
M93L-800/5D
3 per Meter

Section

Fuse Combination Units


Loadswitch Range (Housed Skeleton
Disconnectors 16-800A)

Overview
Key Features
80kA short-circuit capacity
Housed or skeleton versions
Integral cable spreading facility
with choice of position
AC23A utilisation category
IP rated switch disconnectors
Switch disconnectors in sheet
steel enclosures

Benefits
Ease of installation
Accepts large cables
Rated for continuous
full-rated load

Compliance
Fuse switches

EN 60947-3

The Dorman Smith Loadswitch fuse combination range


includes skeleton switches, housed switches and switch
disconnectors. All Loadswitch fuse combination units
exceed EN 60947-3 requirements and amply meet
specifications for full uninterrupted duty to ensure that
switches will maintain the maximum rated load
indefinitely. Given their utilisation category of AC23A
and a short-circuit capacity of 80kA, Loadswitch fuse
combination devices provide complete confidence
when installed in any resistive or inductive load
application. Housed switches are supplied in sheet steel
boxes with integral cable spreading space that can
be positioned above or below the switch to suit ease
of installation.
The switch disconnector units are supplied in either
IP65 insulated enclosures or sheet steel boxes.
The robust steel enclosures are finished in light grey
RAL 7035 epoxy powder coating and have doors that
open 180 for ease of access. Padlocking is arranged to
be off as standard and up to three padlocks can be
attached with ease.

82

Housed Switches

315/400A
32A

160/200A

630/800A
63/125A

Skeleton Switches

160/200A
63/125A

315/400A
630/800A

83

Loadswitch
Enclosed Fuse Switch Combination Units 32A-800A
Housed Switches 32A Complete
with Fuses
Exceeds the requirements of EN
60947-3
All terminals supplied with cable
clamps
Full withstand duty

80kA rms fused short-circuit capacity


415V AC rated voltage
Supplied with fuse links, solid links are
an optional accessory
AC23A utilisation category
IP4X Ingress Protection
Not supplied with fuse links
For fuse links see page 89

Current rating (A)

3-pole cat. no.

3-pole+N cat. no.

4-pole cat. no.

32

HBE3P32N

Housed Switches 63/125A


Complete with Fuses
Exceeds the requirements of EN
60947-3
All terminals supplied with lug-fixing
screws
Full withstand duty

80kA rms fused short-circuit capacity


415V AC rated voltage
Supplied with fuse links, solid links are
an optional accessory
AC23A utilisation category
IP4X Ingress Protection
Not supplied with fuse links
For fuse links see page 89

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

63
100
125

HBF3P63N
HBF3P100N
HBF3P125N

HBF4P100
-

Housed Switches 160/200A


Exceeds the requirements of EN
60947-3
All terminals supplied with lug-fixing
screws
Full withstand duty

80kA rms fused short-circuit capacity


415V AC rated voltage
AC23A utilisation category
IP4X Ingress Protection
Not supplied with fuse links
For fuse links see page 89

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

160
200

HBF3P160N
HBF3P200N

HBF4P200

For solid isolator links see page 85.

Housed Switches 315/400A


Exceeds the requirements of EN
60947-3
All terminals supplied with lug-fixing
screws
Full withstand duty

80kA rms fused short-circuit capacity


415V AC rated voltage
AC23A utilisation category
IP4X Ingress Protection
Not supplied with fuse links
For fuse links see page 89

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

315
400

HBK3P315N
HBL3P400N

HBL4P400

For solid isolator links see page 85.

Housed Switches 630/800A


Exceeds the requirements of EN
60947-3
All terminals supplied with lug-fixing
screws
Full withstand duty

80kA rms fused short-circuit capacity


415V AC rated voltage
AC23A utilisation category
IP4X Ingress Protection
Not supplied with fuse links
For fuse links see page 89

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

630
800

HBN3P630N
HBN3P800N

HBN4P800

For solid isolator links see page 85.

84

Loadswitch
Enclosed Fuse Switch Combination Units Accessories
Accessories for Housed Switches
Description

Current
rating (A)

Cable spreader box

Picture

63/125
160/200
315/400
630/800
32
63
125-200
315/400
630/800
All
All
63/200
315/800
63/200
315/800
315/800

Solid links (set of 1)

Castell* lock mounting kit


Castell* lock with key (see note)
2-bank auxiliary switch
4-bank auxiliary switch
6-bank auxiliary switch

Cat. no.

1
1
1
1
2
2
2
2
2

3
4
4
4
4
4

HB125CSB
HB200CSB
HB400CSB
HB800CSB
HEL32
HFL63
HFL200A
HLL400
HNL800
SCLK
FS2
SAUX2F
SAUX2N
SAUX4F
SAUX4N
SAUX6N

Note: Standard symbol DS1, special symbols are available direct from Castell. Quote
reference: Castell FS2 - Spigot 9.5mm square x 22.5mm, 65 anti-clockwise to trap key
*Castell is a trademark of Castell Safety International Limited.

32A Top and Bottom Knock


Out Dimensions

Housed Switches Technical Data


Max. current rating (A) = 32
Rated current (A)
Frame size
Mechanical endurance
Fused s/c current kA rms
kW @ 415V AC
Max. cable (mm2)*
Terminals
Max cable lug palm width
Weight (kg)

125

32
E
10,000
80
15
10
Clamp type

Max. current rating (A) =


Rated current (A)
Frame size
Mechanical endurance
Fused s/c current kA rms
kW @ 415V AC
Max. cable (mm2)*
Terminals
Max cable lug palm width
Weight (kg)

63
10,000
80
30
70
M8
22
6

100
F
10,000
80
55
70
M8
22
6

200
125

160

200

8,000
80
75
70
M8
22
6

F
8,000
80
90
150
M8
22
12

8,000
80
110
150
M8
22
12

400
315
K
8,000
80
160
185**
M10
M10
35
21

800

400
L
5,000
80
230
300
M10
M10
50
21

630
N
5,000
80
330
630
4xM8
1xM16
80
37

800
N
3,000
80
450
630
4xM8
1xM16
80
37

63 - 125A Top and Bottom


Knock Out Dimensions

* These figures are for guidance only and are dependent upon lug palm width.
** 240mm2 with terminal barriers

Housed Switches Dimensions


Current
rating (A)

Height
(mm)

Width
(mm)

32
63
100
125
160
200
315
400
630
800

210
420
420
420
525
525
735
735
840
840

210
263
263
263
315
315
420
420
630
630

Depth over
handle (mm)
220
273
273
273
325
325
325
325
378
378

Weight
(kg)
3
6
6
6
12
12
21
21
37
37

630-800A Loadswitch Terminal

Spreader Box Dimensions


Current
rating (A)

Height
(mm)

Width
(mm)

63A-125A
200A
315-400A
630-800A

105
105
210
210

263
315
420
630

Depth over
handle (mm)
183
235
235
288

Weight
(kg)
HB125CSB
HB200CSB
HB400CSB
HB800CSB

All dimensions in mm

85

Loadswitch
Skeleton Switches (Without Fuses)
Skeleton Switches 63/125A

Exceeds the requirements of EN 60947-3


80kA rms fused short-circuit capacity
AC23A utilisation category
Full uninterrupted duty
415V AC rated voltage
Lug fixings not supplied

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

63
100
125

SF3P63N
SF3P100N
SF3P125N

SF4P63
SF4P100
SF4P125

Skeleton Switches 160/200A

Exceeds the requirements of EN 60947-3


80kA rms fused short-circuit capacity
AC23A utilisation category
Full uninterrupted duty
415V AC rated voltage
Lug fixings not supplied

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

160
200

SF3P160N
SF3P200N

SF4P160
SF4P200

Skeleton Switches 315/400A

Exceeds the requirements of EN 60947-3


80kA rms fused short-circuit capacity
AC23A utilisation category
Full uninterrupted duty
415V AC rated voltage
Lug fixings not supplied

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

315
400

SK3P315N
SL3P400N

SK4P315
SL4P400

Skeleton Switches 630/800A

Exceeds the requirements of EN 60947-3


80kA rms fused short-circuit capacity
AC23A utilisation category
Full uninterrupted duty
415V AC rated voltage
Lug fixings not supplied

Current rating (A)

3-pole+N cat. no.

4-pole cat. no.

630
800

SN3P630N
SN3P800N

SN4P630
SN4P800

For fuse links see page 89.

86

Loadswitch
Skeleton Switch Accessories
Accessories for Skeleton Switches
1
Description

Current
rating (A)

Picture

Cat. no.

Cable extension terminals (set of 8)


Solid links (set of 1)

630/800
63
100/200
315/400
630/800
63/200
315/800
63/200
315/800
315/800

1
1
1
1
3
3
3
3
3

SNCET
HFL63
HFL200A
HLL400
HNL800
SAUX2F
SAUX2N
SAUX4F
SAUX4N
SAUX6N

All
32/800

SCLK
FS2

63A - 200A
315A - 800A
63A - 200A
315A - 800A

5
5
5
5
4
4
4
4

SHA1
SHA2
SHA3
SHA4
SXT127
SXT227
SXT160
SXT260

160/200

SFTSL

63/200
315
400
630/800
63/200
315
400
630/800
63/125
160/200
315
400
630/800
63
100
125
160
200
315
400
630
800

6
6
6
6
6
6
6
6
6

SFTSS
SKTS
SLTS
SNTS
SFTB
SKTB
SLTB
Supplied
SFFS125
SFFS200
SKFS
SLFS
SNFS
SRLB63
SRLB100
SRLB125
SRLB160
SRLB200
SRLB315
SRLB400
SRLB630
SRLB800

2-bank auxiliary switch


4-bank auxiliary switch
6-bank auxiliary switch
Castell* lock mounting kit
(standard symbol DS1 see note)
Castell* lock with key
Handle assembly for:
E frame - standard size
F frame - standard size
K + L frame - special reduced size
KL+N frame - standard size
Shaft extensions
for panel depth 270mm
Shaft extensions
for panel depth 600mm
Terminal shrouds

6
5

(recommended for cable sizes above 70mm)

Terminal barriers (set of 3)

Fuse shrouds (set of 3)

Rating label (strip of 8)

Note: Special symbols are available direct from Castell.


Quote reference: Castell FS2 - Spigot 9.5mm square x 22.5mm, 65 anti clockwise
to trap key.
*Castell is a trademark of Castell Safety International Ltd.

87

Loadswitch
Technical Data
Skeleton Switches Dimensions

630/800A Standard Terminal

630/800A extension
terminal (accessory)

Dimensions
Frame

F 63A
F100-125A
F 160-200A
K 315A
L 400A
N 630-800A

80
80
80
60
60
100

135
135
135
180
180
180

170
170
170
220
220
235

186
186
186
250
250
255

270
270
300
384
414
534

35
35
35
52.5
70
105

140
140
140
210
280
420

150
150
150
225
295
460

165
165
165
235
305
475

50
50
50
90
125
195

73
94
94
111
111
133

N/A
N/A
N/A
N/A
N/A
184

30
30
30
45
45
60

80
80
80
87
87
129

160
160
196
210
210
240

161
161
197
212
212
242

3
3
3
5
5
5

M5
M5
M5
M5
M5
M6

170*
170*
220
220
220
270

M8
M8
M8
M12
M12
M12

20
20
20
35
50
80

* Supplied suitable for an X dimension of 220mm, the drive shaft can be cut to give a minimum X dimension of 170mm.

Skeleton Switches Technical Data


Max. current rating (A) =
Rated current (A)
Frame size
Mechanical endurance
Fused s/c current kA rms
kW @ 415V AC
Max. cable (mm2)*
Terminals
Max cable lug palm width
Weight (kg)

125
63
F
10,000
80
30
70
M8
22
6

100
F
10,000
80
55
70
M8
22
6

Max. current rating (A) =


Rated current (A)
Frame size
Mechanical endurance
Fused s/c current kA rms
kW @ 415V AC
Max. cable (mm2)*
Terminals
Max cable lug palm width
Weight (kg)

200
125
F
8,000
80
75
70
M8
22
6

400
315
K
8,000
80
160
185**
M12
M12
35
21

200
F
8,000
80
110
150
M8
22
12
800

400
L
5,000
80
230
300
M12
M12
50
21

* These figures are for guidance only and are dependent upon lug palm width
** 240mm2 with terminal barriers
*** Only with cable extension terminals (SNCET)

88

160
F
8,000
80
90
150
M8
22
12

630
N
5,000
80
330
630
4xM8***
1xM16***
80
37

800
N
3,000
80
450
630
4xM8***
1xM16***
80
37

Loadswitch
Fuse Comparison Chart - 415V
Standard
switch

HBE3P32N

HBF/SF3P63
HBF/SF3P63N
HBF/SF4P63

HBF/SF3P100
HBF/SF3P100N
HBF/SF4P100

HBF/SF3P125
HBF/SF3P125N
HBF/SF4P125
HBF/SF3P160
HBF/SF3P160N
HBF/SF4P160
HBF/SF3P200
HBF/SF3P200N
HBF/SF4P200

HBK/SK3P315
HBK/SK3P315N
HBK/SK4P315
HBL/SL3P400
HBL/SL3P400N
HBL/SL4P400

HBN/SN3P630
HBN/SN3P630N
HBN/SN4P630
HBN/SN3P800
HBN/SN3P800N
HBN/SN4P800

Bussman

GEC/
Lawson

MEM

Tag type

BS88 ref

Fuse fixing
centres (mm)

NITD2
NITD4
NITD6
NITD10
NITD16
NITD20
NITD25
NITD32
AAO2
AAO4
AAO6
AAO10
AAO16
AAO20
AAO25
AAO32
BAO40
BAO50
BAO63

CEO32
CEO40
CEO50
CEO63
CE080
CEO100

NIT2
NIT4
NIT6
NIT10
NIT16
NIT20
NIT25*
NIT32*
TIA2
TIA4
TIA6
TIA10
TIA16
TIA20
TIA25
TIA32
TIS40
TIS50
TIS63
TCP6*
TCP10*
TCP16*
TCP20*
TCP25*
TCP32*
TCP40*
TCP50*
TCP63*
TCP80
TCP100

2SA2
4SA2
6SA2
10SA2
16SA2
20SA2
25SA2
32SA2
2SB3
4SB3
6SB3
10SB3
16SB3
20SB3
25SB3
32SB3
40SB4
50SB4
63SB4

80SD5
100SD5

OFFSET

A1

44.5

OFFSET

A2

73.0

OFFSET

A3

73.0

OFFSET

A4 (dia 33 max)

94.0

DEO125

TFP125

125SD6

OFFSET

A4

94.0

DEO160

TFP160

160SD6

OFFSET

A4 (dia 38 max)

94.0

DEO200

TFP200

200SD6

OFFSET

A4 (dia 38 max)

94.0

CD80
CD100
DD125
DD160
DD200
ED250
ED315

TC80
TC100
TF125
TF160
TF200
TKF250
TKF315

80SF5
100SF5
125SF6
160SF6
200SF6
250SF7
315SF7

CENTRE

B1

111.0

CENTRE

B2

111.0

CENTRE

B3 (dia 50 max)

111.0

EF355
EF400
FF450
FF500
FF560
FF630

GF710

GF800

TM355
TM400
TTM450
TTM500
TTM560
TTM630
TLM670
TLM710
TLM750
TLM800

355SH8
400SH8
450SH9
500SH9
560SH9
630SH9

710SH10

800SH10

CENTRE

C1

133.0

CENTRE

C2

133.0

CENTRE

C3

133.0

Inserted
switch

SFT3P63
SFT3P63N
SFT4P63

SFT3P100
SFT3P100N
SFT4P100

SFT3P125
SFT3P125N
SFT4P125
SFT3P160
SFT3P160N
SFT4P160
SFT3P200
SFT3P200N
SFT4P200
SKT3P315
SKT3P315N
SKT4P315
SLT3P400
SLT3P400N
SLT4P400
SNT3P630
SNT3P630N
SNT4P630

SNT3P800
SNT3P800N
SNT4P800

NOTE:
1. The comparative types are a guide to interchangeability, with regard to dimensions and current rating only. It is essential
that rated voltage and other electrical characteristics are checked to ensure compatability.
2. Please check maximum barrel size prior to fitting.
3. *Lawson fuse reference only.

89

Loadswitch
Switch Disconnectors in IP rated Enclosures
Switch Disconnectors in IP65 Insulated Enclosures

Conforms to EN 60947-3
Padlockable handle
Rotary handle accepts three padlocks
Terminals accept large cables
Includes earth and neutral terminals
IP65 ingress protection

Current rating (A)

3-pole cat. no.

16
25
32
40
63
80
100
125

PS16NY
PS25NY
PS32NY
PS40NY
PS63NY
PS80NY
PS100NY
PS125NY

Technical Data for Disconnectors in IP65 Insulated Enclosures


Current rating (A)

16

25

32

40

63

80

100

125

Rated insulation voltage Ui (V)


Dielectric strength (kV) 50 Hz 1 min
Shock resistance Uimp (kV)
Operational current Ie (A)
415V AC AC21A/AC21B
AC22A/AC22B
AC23A/AC23B
500V AC AC21A/AC21B
AC22A/AC22B
AC23A/AC23B
690V AC AC20A/AC20B
AC21A/AC21B
AC22A/AC22B
AC23A/AC23B
Motor power (kW) AC23
415V AC
500V AC
690V AC
Overload capacity at 415V AC
Fuse rating
Short-circuit current with fuses (kA rms)
Asymmetric short time rating
current (kA peak)
Admissible short time current 1s (kA rms)
Making and breaking characteristics
Breaking capacity (A rms) 415V AC23A
Making capacity (A rms) 415V AC23A
Withstand
Mechanical (number of operations) x 1000
Electrical (no. of operations at 415V
AC23A) x 1000
Connection
Maximum Cu cable section (mm2)
Using stranded cable (mm2)

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

16
16
16
16
16
16
16
16
16
16

25
25
25
25
25
25
25
25
25
25

32
32
32
32
32
32
32
32
32
25

40
40
40
40
40
40
40
40
40
25

63
63
63
63
63
40
63
63
63
25

80
80
80
80
80
63
80
80
80
50

100
100
80
100
100
63
100
100
100
50

125
125
80
125
125
63
125
125
100
50

7.5
7.5
11

9
9
11

11
11
11

11
15
18.5

15
18.5
18.5

22
30
30

37
37
30

40
37
30

16
50

25
50

32
50

40
50

63/40
20/50

80
25

100
25

125
11

6
1.26

6
1.26

6
1.26

6
1.26

6
1.26

9
1.5

9
1.5

9
1.5

128
160

200
250

256
320

320
400

504
630

640
800

640
800

640
800

100

100

100

100

100

30

30

30

1.5

1.5

1.5

16
25

16
25

16
25

16
25

16
25

50

50

50

Dimensions

90

Current
rating (A)

Height
(mm)

Width
(mm)

Depth over
handle (mm)

Weight
(kg)

16
25
32
40
63
80
100
125

133
133
175
175
300
400
400
400

86
86
125
125
200
300
300
300

104
104
136
136
168
168
168
168

0.36
0.36
0.75
0.75
1.82
2.74
2.74
2.74

Loadswitch
Switch Disconnectors in Sheet Steel Enclosures
Switch Disconnectors in Sheet Steel Enclosures

Conforms to EN 60947-3
Padlockable handle
Rotary handle accepts three padlocks
Terminals accept large cables
IP4X ingress protection

Current rating (A)

3-pole cat. no.

3-pole+N cat. no.

20
32
40
63
63
100
125

HS13P20
HS13P32
HS13P40
HS13P63
HS23P63
HS23P100
HS23P125

HS13P20N
HS13P32N
HS13P40N
HS13P63N
HS23P63N
HS23P100N
HS23P125N

Technical Data for Disconnectors in IP65 Insulated Enclosures


Current rating (A)

16

25

32

40

63

80

100

125

Rated insulation voltage Ui (V)


Dielectric strength (kV) 50 Hz 1 min
Shock resistance Uimp (kV)
Operational current Ie (A)
415V AC AC21A/AC21B
AC22A/AC22B
AC23A/AC23B
500V AC AC21A/AC21B
AC22A/AC22B
AC23A/AC23B
690V AC AC20A/AC20B
AC21A/AC21B
AC22A/AC22B
AC23A/AC23B
Motor power (kW) AC23
415V AC
500V AC
690V AC
Overload capacity at 415V AC
Fuse rating
Short-circuit current with fuses (kA rms)
Asymmetric short time rating
current (kA peak)
Admissible short time current 1s (kA rms)
Making and breaking characteristics
Breaking capacity (A rms) 415V AC23A
Making capacity (A rms) 415V AC23A
Withstand
Mechanical (number of operations) x 1000
Electrical (no. of operations at 415V
AC23A) x 1000
Connection
Maximum Cu cable section (mm2)
Using stranded cable (mm2)

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

800
3
8

16
16
16
16
16
16
16
16
16
16

25
25
25
25
25
25
25
25
25
25

32
32
32
32
32
32
32
32
32
25

40
40
40
40
40
40
40
40
40
25

63
63
63
63
63
40
63
63
63
25

80
80
80
80
80
63
80
80
80
50

100
100
80
100
100
63
100
100
100
50

125
125
80
125
125
63
125
125
100
50

7.5
7.5
11

9
9
11

11
11
11

11
15
18.5

15
18.5
18.5

22
30
30

37
37
30

40
37
30

16
50

25
50

32
50

40
50

63/40
20/50

80
25

100
25

125
11

6
1.26

6
1.26

6
1.26

6
1.26

6
1.26

9
1.5

9
1.5

9
1.5

128
160

200
250

256
320

320
400

504
630

640
800

640
800

640
800

100

100

100

100

100

30

30

30

1.5

1.5

1.5

16
25

16
25

16
25

16
25

16
25

50

50

50

Dimensions

Disconnectors
Current
rating (A)

Height
(mm)

Width
(mm)

Depth over
handle (mm)

Weight
(kg)
3-pole

20
32
40
63
63
100
125

210
210
210
210
315
315
315

158
158
158
158
158
158
158

173
173
173
173
173
173
173

2.0
2.0
2.0
2.0
2.5
2.5
2.5

4-pole
2.2
2.2
2.2
2.2
2.7
2.7
2.7

91

Loadswitch
Switch Disconnectors Accessories
Accessories for Switch Disconnectors

92

Description

Current rating (A)

Cat. no.

63A neutral link


125A neutral link
10A auxiliary switch
Terminal shroud (set of 2):
1-pole
3-pole
1-pole
3-pole

All
All
All

HSNL63
HSNL125
HSAUX

16/63
16/63
63/125
63/125

HSTS163
HSTS363
HSTS1125
HSTS3125

Section

Dorman Smith Circuit Protection


and Modular Devices

Circuit Protection Devices


Loadlimiter 63 Miniature Circuit Breakers 10/15kA
10kA/15kA MCBs

Exceeds the requirements of EN 60898


Contact position indicator
35mm2 cable capacity
Multiples of 17.5mm width
10kA rated to the requirements of EN60898
15kA rated to the requirements EN60947

Current rating (A)


Single-pole MCBs
6
10
13
16
20
25
32
40
50
63
Double-pole MCBs
6
10
13
16
20
25
32
40
50
63
Triple-pole MCBs
6
10
13
16
20
25
32
40
50
63

Dimensions

94

B type cat. no.

C type cat. no.

D type cat. no.

K1PB06
K1PB10
K1PB13
K1PB16
K1PB20
K1PB25
K1PB32
K1PB40
K1PB50
K1PB63

K1PC06
K1PC10
K1PC13
K1PC16
K1PC20
K1PC25
K1PC32
K1PC40
K1PC50
K1PC63

K1PD06
K1PD10
N/A
K1PD16
K1PD20
K1PD25
K1PD32
T1PD40*
T1PD50*
T1PD63*

K2PB06
K2PB10
N/A
K2PB16
K2PB20
K2PB25
K2PB32
K2PB40
K2PB50
K2PB63

K2PC06
K2PC10
N/A
K2PC16
K2PC20
X2PC25
K2PC32
K2PC40
K2PC50
K2PC63

K2PD06
K2PD10
N/A
K2PD16
K2PD20
K2PD25
K2PD32
T2PD40*
T2PD50*
T2PD63*

K3PB06
K3PB10
N/A
K3PB16
K3PB20
K3PB25
K3PB32
K3PB40
K3PB50
K3PB63

K3PC06
K3PC10
N/A
K3PC16
K3PC20
K3PC25
K3PC32
K3PC40
K3PC50
K3PC63

K3PD06
K3PD10
N/A
K3PD16
K3PD20
K3PD25
K3PD32
T3PD40*
T3PD50*
T3PD63*

Circuit Protection Devices


Loadlimiter 63 Residual Current Circuit Breaker with Overload
10kA RCBOs

Exceeds the requirements of EN 61009


Single module: Type AC
10kA rated breaking capacity
Terminal capacity: outgoing terminals 10mm2
Terminal capacity: busbar side terminals 35mm2

Current rating (A)

Sensitivity

B type cat. no.

C type cat. no.

6
10
16
20
32
40
45
6
10
16
20
32
40

30
30
30
30
30
30
30
100
100
100
100
100
100

KR1PB0630
KR1PB1030
KR1PB1630
KR1PB2030
KR1PB3230
KR1PB4030
KR1PB4530
-

KR1PC0630
KR1PC1030
KR1PC1630
KR1PC2030
KR1PC3230
KR1PC4030
KR1PC4530
KR1PC06100
KR1PC10100
KR1PC16100
KR1PC20100
KR1PC32100
KR1PC40100

Double Module RCBOs


Energy limiting class 3
Type AC
Terminal capacity: outgoing
terminals 35mm2
Terminal capacity: busbar side
terminals 35mm2

Exceeds the requirements of


EN 61009, IEC 61009
SP&SwN configuration
Rated breaking capacity up to 10kA
Contact position indicator
Rated voltage Ue ~230V
Rated frequency 50Hz
Current rating (A)

30m/A cat. no.

6
10
16
20
32
40

KR2PB0630
KR2PB1030
KR2PB1630
KR2PB2030
KR2PB3230
KR2PB4030

Accessories for 10kA MCBs and RCBOs


Auxiliary equipment

Cat. no.

MCB shunt trip (240V AC)


MCB auxiliary/switch contact

KST240
KAUX1

Padlocking
MCB dolly locking device
Padlock for dolly locking device

KDL
XPL

Dimensions
Single Module

Double Module
126.4

6.6

6.8

4.3

43.1

69.5

45

98.2
109

17.4

34.5

95

Circuit Protection Devices


Loadlimiter 63 Miniature Circuit Breakers 6kA/10kA
6kA/10kA MCBs

Exceeds the requirements of EN 60898


6kA rated breaking capacity to EN 60898
Contact position indicator
25mm2 cable capacity
10kA rated breaking capacity to EN 60947-2

Current rating (A)


Single-pole MCBs
6
10
16
20
25
32
40
50
63
Double-pole MCBs
6
10
16
20
25
32
40
50
63
Triple-pole MCBs
6
10
16
20
25
32
40
50
63

Dimensions

96

B type cat. no.

C type cat. no.

D type cat. no.

S1PB06
S1PB10
S1PB16
S1PB20
S1PB25
S1PB32
S1PB40
S1PB50
S1PB63

S1PC06
S1PC10
S1PC16
S1PC20
S1PC25
S1PC32
S1PC40
S1PC50
S1PC63

S1PD06
S1PD10
S1PD16
S1PD20
S1PD25
S1PD32
S1PD40
S1PD50
S1PD63

S2PB06
S2PB10
S2PB16
S2PB20
S2PB25
S2PB32
S2PB40
S2PB50
S2PB63

S2PC06
S2PC10
S2PC16
S2PC20
S2PC25
S2PC32
S2PC40
S2PC50
S2PC63

S2PD06
S2PD10
S2PD16
S2PD20
S2PD25
S2PD32
S2PD40
S2PD50
S2PD63

S3PB06
S3PB10
S3PB16
S3PB20
S3PB25
S3PB32
S3PB40
S3PB50
S3PB63

S3PC06
S3PC10
S3PC16
S3PC20
S3PC25
S3PC32
S3PC40
S3PC50
S3PC63

S3PD06
S3PD10
S3PD16
S3PD20
S3PD25
S3PD32
S3PD40
S3PD50
S3PD63

Circuit Protection Devices


Loadlimiter 63 Residual Current Circuit Breakers
RCCBs

Exceeds the requirements of EN 61008


Voltage 230/400V 50/60Hz
Type AC
Terminal capacity: top 25mm2
Terminal capacity: bottom 35mm2

Double-pole RCCBs
Current rating (A)
40
40
63
63
63
80
100
100
100, time delay

Sensitivity (mA)
30
100
30
100
300
30
30
100
100

Type

Width (mm)

Cat. no.

AC
AC
AC
AC
AC
AC
AC
AC
AC

35
35
35
35
35
35
35
35
35

EE40/30/2
EE40/100/2
EE63/30/2
EE63/100/2
EE63/300/2
EE80/30/2
EE100/30/2
EE100/100/2
EES100/100/2

Type

Width (mm)

Cat. no.

AC
AC
AC
AC
AC
AC
AC
AC
AC
AC

70
70
70
70
70
70
70
70
70
70

EE40/30/4
EE40/100/4
EE40/300/4
EE63/30/4
EE63/100/4
EE63/300/4
EE100/30/4
EE100/100/4
EE100/300/4
EES100/100/4

Four-pole RCCBs
Current rating (A)
40
40
40
63
63
63
100
100
100
100, time delay

Sensitivity (mA)
30
100
300
30
100
300
30
100
300
100

Dimensions
4-pole

2-pole

97

Circuit Protection Devices


Loadline Moulded Case Circuit Breakers
Frame

YB1N

Maximum amps
No. of poles
Adjustable thermal
Adjustable magnetics
Rated current (A). [In]

1
N
N
Nom

16
20
25
32
40
50
63
80
100
125
160
200
250
400
Rated impulse withstand
voltage Uimp [kV]
AC rated insulation
voltage [Ui]
AC rated breaking capacity
IEC 947-2
690V
EN 60947-2
525V
BS EN60947-2
440V
415V
400V
380V
240V
220V
NEMA AB-1
600V
480V
240V
Without instantaneous
240-690V
DC rated
250V
breaking
125V
capacity
[kA]
Rated short time
current r.m.s. [kA] [Icw]
Utilisation category

16
20
25
32
40
50
63
80
100
125

YA2N
160
3

4
Y
N

Adj
min max
10
16
13
20

20
32

32
50
40
63

63
100
80
125
100
160
125

160

1
N
N
Nom
16
20
25
32
40
50
63
80
100
125

690
Icu

25

YA2S
125
3

min

13

20

32
40

63
80

125
4
Y
Y
Adj
max

20

32

50
63

100
125

Ics

7.5
13
25
25
25
35
35

4
7.5
13
13
13
25
25

7
10

7
10

Adj
min

20

32
40

63
80

Adj
max

32

50
63

100
125

Adj
min

20

32
40

63
80

8
800

YB3N
125
4
Y
Y
Adj
max

32

50
63

100
125

250
1

4
Y
N

Adj
min

32
40

63
80
100
125
160

Adj
max

50
63

100
125
160
200
250

800

690

Icu

25

Icu

8
15
25
25
25
35
35

8
35

Ics

6
12
19
19
19
27
27

Icu
6
22
25
36
36
36
50
50

22
50

Ics
6
22
25
36/30
36/30
36/30
50
50

Icu
6
25
25
65
65
65
85
85

22
50

Ics
6
22
25
36/33
36/33
36/33
85
85

Icu

7.5
15
25
25
25
35
35

22
50

Ics

6
12
19
19
19
27
27

25

19

25

19

40

40

15
25

12
19

Notes: *Value at1/ 3 times stated voltage. ** Not applicable to IT systems at voltage shown.

98

Y
Y

800

Icu

YA2J

Circuit Protection Devices


Loadline Moulded Case Circuit Breakers
Frame
Maximum amps
No. of poles
Adjustable thermal
Adjustable magnetics
Rated current
(A). [In]
16
20
25
32
40
50
63
80
100
125
160
200
250
400
Rated impulse withstand
voltage Uimp
[kV]
AC rated insulation
voltage [Ui]
AC rated breaking capacity
IEC 947-2
690V
EN 60947-2
525V
CEI EN 60947-2
440V
415V
400V
380V
240V
220V
NEMA AB-1
600V
480V
240V
Without
instantaneous
240-690V
DC rated
250V
breaking
125V
capacity
[kA]
Rated short time
current r.m.s.
[kA] [Icw]
Utilisation category

YA3N
1
N
N
Nom
16
20
25
32
40
50
63
80
100
125
160

YA3S
250
3

min

13

20

32
40

63
80
100
125
160

YA3J
250

4
Y
N

Adj
max

20

32

50
63

100
125
160
200
250

250

Y
Y
Adj
min

13

20

32
40

63
80
100
125
160

800

YA5N
400
4

Y
Y
Adj
max

20

32

50
63

100
125
160
200
250

YA5H
400
4

Adj
min

20

32
40

63
80
100
125
160

Y
Y
Adj
max

32

50
63

100
125
160
200
250

Adj
min

160
250

4
Y
N

Adj
max

250
400

Adj
min

160
250

Adj
max

250
400

800

800

800

800

Icu

25
25

Icu

10
15
25
25
25
35
35

10
35

Ics

7.5
12
19
19
19
27
27

Icu
7.5
25
25
36***
36***
36***
65
65

22
65

Ics
7.5
25
25
36***
36***
36***
65
65

Icu
7.5
25
25
65
65
65
85
85

22
85

Ics
7.5
25
25
65
65
65
85
85

Icu

15
22
25
25
25
35
35

15
35

Ics

15
22
25
25
25
35
35

Icu
20
30
45
50
50
50
35
35

22
50

Ics
15
30
45
50
50
50
85
85

19

25

25

40

40

40

40

25

25

40

40

Notes: *Value at1/ 3 times stated voltage. ** Not applicable to IT systems at voltage shown. ***20A and 32A only rated at 30kA at this voltage.

99

Circuit Protection Devices


Loadline Moulded Case Circuit Breakers
Frame

Maximum
amps
No. of poles
Adjustable
thermal
Adjustable
magnetics
Rated current
(A). [In]
50
63
80
100
125
160
200
250
400
630
800
1000
1250
1600
Rated impulse
withstand
voltage Uimp
[kV]
AC rated
insulation
voltage [Ui]
AC rated
breaking
symmetrical
r.m.s. [kA]
IEC 947-2
EN 60947-2
BS EN 60947-2

NEMA AB-1

YA5H
Electronic

YA5K
Electronic

400

400

Y6K
Thermal/
Magnetic

800A

800A

Adj
min

100
160

690V
525V
500V
415V
400V
380V
240V
220V
600V
480V
400V
240V

Y6H
Thermal/
Magnetic and
Generator

Adj
max

250
400

Adj
min

100
160

Adj
max

250
400

800

800

Nom

400
630
800

min

250
400
500

Adj
max

400
630
800

Nom

400
630
800

690

Adj
min

250
400
500

690

Icu

Ics

Icu

Ics

Icu

Ics

Icu

Ics

20
30

50
50
50
85
85

15
30

50
50
50
85
35

20
30

70
70
70
100
100

15
30

50
50
50
85
85

20

35
50
65
65
85
85

10**

18**
25
33
33
43
43

45

65
85
100
100
125
125

23**

33**
50
50
50
63
63

25

85

30

100

30

50
85

50
50

50
50

Without
instantaneous
240-690V
DC rated
250V
breaking
125V
capacity
[kA]
Rated short time
current r.m.s. [kA]
[Icw]
Utilisation category

Notes: *Value at1/ 3 times stated voltage. ** Not applicable to IT systems at voltage shown.

100

max

400
630
800

Circuit Protection Devices


Loadline Moulded Case Circuit Breakers
Frame

Maximum
amps
No. of poles
Adjustable
thermal
Adjustable
magnetics
Rated current
(A). [In]
50
63
80
100
125
160
200
250
400
630
800
1000
1250
1600
Rated impulse
withstand
voltage Uimp
[kV]
AC rated
insulation
voltage [Ui]
AC rated
breaking
symmetrical
r.m.s. [kA]
IEC 947-2
EN 60947-2
BS EN
60947-2

NEMA AB-1

Y6H-E
Electronic

Y6J-E
Electronic
800A

800A

Y8K-E
Electronic
1250A

1600A

Nom

630
800

Y7J-E
Electronic

Adj
min

315
400

Nom
max

630
800

630
800

690

Adj
min

315
400

Nom
max

630
800

1000
1250

690

Adj
min

500
630

Nom
max

1000
1250

1600

690

Adj
min

800
8

max

1600

690

Icu

Ics

Icu

Ics

Icu

Ics

Icu

Ics

690V
500V
400V

20
35
50

10**
18**
25

20
42
65

10**
21**
50

25
45
65

19**
34**
49

35
65
85

35**
49**
64

415V
400V
380V
240V
220V
600V
400V
240V

50
50
50
85
85

25
25
25
43
43

65
65
65
100
100

50
50
50
50
50

65
85
85
100
100

49
64
64
75
75

85
100
100
125
125

64
75
75
94
94

30
50
85

42
65
85

10

10

15

20

10 (0.3 sec)

10 (0.3 sec)

15 (0.3 sec)

20 (0.3 sec)

Without
instantaneous
240-690V
DC rated
250V
breaking
125V
capacity
[kA]
Rated short time
current r.m.s. [kA] [Icw]
Utilisation category

Notes: *Value at 1/ 3 times stated voltage. ** Not applicable to IT systems at voltage shown.

101

Circuit Protection Devices


Loadline YB1 and YB3 Frame Moulded Circuit Case Breakers
YB1 Frame MCCBs (Available 2012)
Standard cable termination = 50mm2
Triple-pole and four-pole have adjustable thermal overloads only
Single-pole devices have fixed thermal and magnetic overloads

Current rating (A)

1-pole Cat no.

3-pole Cat No.

YB1 Frame Switch Disconnector


160
YB1B3P160D
YB1 Frame MCCB Thermal/Magnetic -Icu 25kA
16
YB1N1P16T
20
YB1N1P20T
25
YB1N1P25T
YB1N3P25T
32
YB1N1P32T
YB1N3P32T
40
YB1N1P40T
YB1N3P40T
50
YB1N1P50T
63
YB1N1P63T
YB1N3P63T
80
YB1N1P80T
YB1N3P80T
100
YB1N1P100T
YB1N3P100T
125
YB1N1P125T
YB1N3P125T
160
YB1N3P160T

4-pole Cat no

YB1B4P160D
YB1N4P25T
YB1N4P32T
YB1N4P40T
YB1N4P63T
YB1N4P80T
YB1N4P100T
YB1N4P125T
YB1N4P160T

YB3 Frame MCCBs


Standard cable termination = 95mm2
Maximum cable termination using M8 reduced palm width cable lugs = 150mm2
Triple-pole and four-pole have adjustable thermal overloads only

Current rating (A)

1-pole Cat no.

3-pole Cat No.

YB3 Frame Switch Disconnector


250
YB3B3P250D
YB3 Frame MCCB Thermal/Magnetic -Icu 25kA
50
YB3N3P50T
63
YB3N3P63T
100
YB3N3P100T
125
YB3N3P125T
160
YB3N3P160T
200
YB3N3P200T
250
YB3N3P250T

Dimensions
YB1 1-pole

102

YB1 3-pole and 4-pole

YB3 3-pole and 4-pole

4-pole Cat no

YB3B4P250D
YB3N4P50T
YB3N4P63T
YB3N4P100T
YB3N4P125T
YB3N4P160T
YB3N4P200T
YB3N4P250T

Circuit Protection Devices


Loadline YA2 Frame Moulded Case Circuit Breakers
YA2 Frame MCCBs

Exceeds EN60947-2
Rated insulation voltage is 800V AC (Ui)
Triple and four-pole MCCBs have both adjustable overload and instantaneous trips
Standard M8 cable lug termination = 35mm2
Maximum cable termination = 95mm2 (using M8 reduced palm width lugs)
Current rating (A)

1-pole cat. no.

3-pole cat. no.

YA2 Frame MCCB Thermal/Magnetic Icu 25kA


16
YA2N1P16T
N/A
20
YA2N1P20T
YA2N3P20T
32
YA2N1P32T
YA2N3P32T
50
YA2N1P50T
YA2N3P50T
63
YA2N1P63T
YA2N3P63T
80
YA2N1P80T
100
YA2N1P100T
YA2N3P100T
125
YA2N1P125T
YA2N3P125T
YA2 Frame MCCB Thermal/Magnetic Icu 36kA
50
YA2S3P50T
63
YA2S3P63T
100
YA2S3P100T
125
YA2S3P125T
YA2 Frame MCCB Thermal/Magnetic Icu 65kA
20
YA2J3P20T
32
YA2J3P32T
50
YA2J3P50T
63
YA2J3P63T
100
YA2J3P100T
125
YA2J3P125T

4-pole cat. no.

N/A
YA2N4P20T
YA2N4P32T
YA2N4P50T
YA2N4P63T
YA2N4P100T
YA2N4P125T
YA2S4P50T
YA2S4P63T
YA2S4P100T
YA2S4P125T
YA2J4P20T
YA2J4P32T
YA2J4P50T
YA2J4P63T
YA2J4P100T
YA2J4P125T

Dimensions
YA2 1-pole

YA2 3 and 4-pole

103

Circuit Protection Devices


Loadline YA2 Frame Accessories
YA2 Frame Accessories
Description
Cable clamps
YA2 cable clamps (set of 3)
YA2 cable clamps (set of 4)
Terminals and protection
YA2 1-pole terminal shroud
YA2 3-pole terminal shroud
YA2 4-pole terminal shroud
YA2 terminal barrier
YA2 3-pole terminal cover
YA2 4-pole terminal cover
YA2 3-pole rear terminals
YA2 4-pole rear terminals
YA2 3-pole extension terminals
YA2 4-pole extension terminals
Plug-in units
YA2 3-pole plug-in terminals
YA2 4-pole plug-in terminals
YA2 3-pole plug-in base
YA2 4-pole plug-in base
YA2 3-pole plug-in base extension terminals
YA2 4-pole plug-in base extension terminals
YA2 3-pole right angle terminals
YA2 4-pole right angle terminals
Motors and interlocks
YA2 motor actuator, 100-110V ac
YA2 motor actuator, 200-240V ac
YA2 mechanical changeover, link type
YA2 mechanical changeover, manual slide type
YA2 mechanical changeover, wire type with 1 metre cable
YA2 mechanical changeover, wire type with 1.5 metre cable
Auxiliaries
YA2 dolly lock
YA2 neutral link
YA2 rotary handle standard length
YA2 rotary handle long length
Shunt trips
**YA frame shunt trip 100-120V AC
**YA frame shunt trip 200-240V AC
**YA frame shunt trip 380-450V AC
**YA frame shunt trip 24V DC
Auxiliary and alarm switches
**YA frame 1AB auxiliary switch
**YA frame alarm switch
Under-voltage release
**YA frame under-voltage release 100-120V AC
**YA frame under-voltage release 200-240V AC
**YA frame under-voltage release 380-450V AC
**YA frame under-voltage release 24V DC
** Common to all YA2, YA3, YA5 MCCBs.

104

Cat. no.
YA2CC3P
YA2CC4P
YA2TS1P
YA2TS3P
YA2TS4P
YA2TB
YA2TS3P3
YA2TS4PS
YA2RT3P
YA2RT4P
YA2XT3P
YA2XT4P
YA2PT3P
YA2PT4P
YA2PB3P
YA2PB4P
YA2PXT3P
YA2PXT4P
YA2PRA3P
YA2PRA4P
YA2MA110
YA2MA240
YA2ML
YA2MMS
YA2MW10
YA2MW15
YADL1
YA2NL
YA2R1
YA2R2
YAST115AC
YAST240AC
YAST450AC
YAST24DC
YAAUX1
YAAL
YAUVR120AC
YAUVR240AC
YAUVR450AC
YAUVR24DC

Circuit Protection Devices


Loadline YA3 Frame Moulded Case Circuit Breakers
YA3 Frame MCCBs

Exceeds EN 60947-2 requirements


Triple and four-pole MCCBs have both adjustable overload and instantaneous trips
Rated insulation voltage 800V AC (Ui)
Standard M8 cable lug termination = 95mm2
Maximum cable termination = 150mm2 (using M8 reduced palm width lugs)
Current rating (A)

1-pole cat. no.

3-pole cat. no.

4-pole cat. no.

Max.Min.

YA3 Switch Disconnector


250
YA3B3P250D
YA3 Frame MCCB Thermal/Magnetic - Icu 25kA
16
16
YA3N1P16T
20
13
YA3N1P20T
YA3N3P20T
32
20
YA3N1P32T
YA3N3P32T
40
25
YA3N1P40T
50
32
YA3N1P50T
YA3N3P50T
63
40
YA3N1P63T
YA3N3P63T
80
50
YA3N1P80T
100
63
YA3N1P100T
YA3N3P100T
125
80
YA3N1P125T
YA3N3P125T
160
100
YA3N1P160T
YA3N3P160T
200
125
YA3N3P200T
250
160
YA3N3P250T
YA3 Frame MCCB Thermal/Magnetic Icu 36kA
50
32
YA3S3P50T
63
40
YA3S3P63T
100
63
YA3S3P100T
125
80
YA3S3P125T
160
100
YA3S3P160T
200
125
YA3S3P200T
250
160
YA3S3P250T
YA3 Frame MCCB Thermal/Magnetic Icu 65kA
50
63
100
125
160
200
250

32
40
63
80
100
125
160

YA3J3P50T
YA3J3P63T
YA3J3P100T
YA3J3P125T
YA3J3P160T
YA3J3P200T
YA3J3P250T

YA3B4P250D
YA3N4P20T
YA3N4P32T
YA3N4P50T
YA3N4P63T
YA3N4P100T
YA3N4P125T
YA3N4P160T
YA3N4P200T
YA3N4P250T
YA3S4P50T
YA3S4P63T
YA3S4P100T
YA3S4P125T
YA3S4P160T
YA3S4P200T
YA3S4P250T
YA3JP50T
YA34J63T
YA34J100T
YA34J125T
YA34J160T
YA34J200T
YA34J250T

Dimensions
YA3 1-pole

YA3 3 and 4-pole

105

Circuit Protection Devices


Loadline YA3 Frame Accessories
Description

Cat. no.

Cable clamps
YA3 cable clamps (set of 3)
YA3 cable clamps (set of 4)
Terminals and protection
YA3 1-pole terminal shroud
YA3 3-pole terminal shroud
YA3 4-pole terminal shroud
YA3 terminal barrier
YA3 3-pole terminal cover
YA3 4-pole terminal cover
YA3 3-pole rear terminals
YA3 4-pole rear terminals
YA3 3-pole extension terminals
YA3 4-pole extension terminals
Plug-in units
YA3 3-pole plug-in terminals
YA3 4-pole plug-in terminals
YA3 3-pole plug-in base
YA3 4-pole plug-in base
YA3 3-pole plug-in base extension terminals
YA3 4-pole plug-in base extension terminals
YA3 3-pole right angle terminals
YA3 4-pole right angle terminals
Motors and interlocks
YA3 motor actuator, 100-110V AC
YA3 motor actuator, 200-240V AC
YA3 mechanical changeover, link type
YA3 mechanical changeover, manual slide type
YA3 mechanical changeover, wire type with 1 metre cable
YA3 mechanical changeover, wire type with 1.5 metre cable
Castell* mounting kit (lock to be ordered separately)
Auxiliaries
YA3 dolly lock
YA3 rotary handle standard length
YA3 rotary handle long length

YA3CC3P
YA3CC4P
YA3TS1P
YA3TS3P
YA3TS4P
YA3TB
YA3TS3PS
YA3TS3P3
YA3RT3P
YA3RT4P
YA3XT3P
YA3XT4P
YA3PT3P
YA3PT4P
YA3PB3P
YA3PB4P
YA3PXT3P
YA3PXT4P
YA3PRA3P
YA3PRA4P
YA3MA110
YA3MA240
YA3ML
YA3MMS
YA3MW10
YA3MW15
YACL
YADL1
YA3R1
YA3R2

Adapter Kit AA Frame to YA3 Frame


For use when replacing existing AA frame with YA3 MCCBs.
Description for AA frame kit

Poles

Cat. no.

Loadbank panel board


Loadbank panel board
Type 2 Loadframe switchboard

1
3
3

YAA1PLB
YAA3PLB
YAA3PLFT2

*Castell is a trademark of Castell Safety International Limited.

Note: Shunt trips, UVT, auxiliaries switches, alarm switches - see common
accessories page 104.

106

Circuit Protection Devices


Loadline YA5 Frame Moulded Case Circuit Breakers
YA5 Frame MCCBs

Exceeds EN60947-2 requirements


Triple and four-pole MCCBs have both adjustable overload and instantaneous trips
Rated insulation voltage 800V AC (Ui)
Electronic MCCBs are Category B rated for discrimination
No extension terminal bars supplied, see Accessories if required
Standard M10 cable lug termination = 95mm2
Maximum cable termination = 185mm2 (using M10 reduced palm width lugs)
Current rating (A)

3-pole cat. no.

4-pole cat. no.

Max.Min.

YA5 Switch Disconnector


400
YA5B3P400D
YA5 Frame MCCB Thermal/Magnetic Icu 25kA
250
157
YA5N3P250T
400
252
YA5N3P400T
YA5 Frame MCCB Thermal/Magnetic Icu 50kA

YA5B4P400D

250
157
YA5H3P250T
400
252
YA5H3P400T
YA5 Frame MCCB Thermal/Magnetic Icu 65kA
250
157
YA5J3P250T
400
252
YA5J3P400T
YA5 Frame MCCB Electronic Icu 70kA

YA5H4P250T
YA5H4P400T

250
400

YA5K4P250E
YA5K4P400E

125
200

YA5K3P250E
YA5K3P400E

YA5N4P250T
YA5N4P400T

YA5J4P250T
YA5J4P400T

Dimensions
YA5 3 and 4-pole

107

Circuit Protection Devices


Loadline YA5 Frame Accessories
YA5 Frame MCCB Accessories
Description
Cable clamps
YA5 cable clamps (set of 3)
YA5 cable clamps (set of 4)
Terminals and protection
YA5 3-pole terminal shroud
YA5 4-pole terminal shroud
YA5 terminal barrier
YA5 3-pole terminal cover
YA5 4-pole terminal cover
YA5 3-pole rear terminals
YA5 4-pole rear terminals
YA5 3-pole extension terminals
YA5 4-pole extension terminals
Plug-in units
YA5 3-pole plug-in terminals
YA5 4-pole plug-in terminals
YA5 3-pole plug-in base
YA5 4-pole plug-in base
YA5 3-pole plug-in base extension terminals
YA5 4-pole plug-in base extension terminals
YA5 3-pole right angle terminals
YA5 4-pole right angle terminals
Motors and interlocks
YA5 motor actuator, 100-110V ac
YA5 motor actuator, 200-240V ac
YA5 mechanical changeover, link type
YA5 mechanical changeover, manual slide type
YA5 mechanical changeover, wire type with 1 metre cable
YA5 mechanical changeover, wire type with 1.5 metre cable
Auxiliaries
YA5 dolly lock
YA5 neutral link
YA5 rotary handle standard length
YA5 rotary handle long length

Cat. no.
YA5CC3P
YA5CC4P
YA5TS3P
YA5TS4P
YA5TB
YA5TC3P
YA5TC4P
YA5RT3P
YA5RT4P
YA5XT3P
YA5XT4P
YA5PT3P
YA5PT4P
YA5PB3P
YA5PB4P
YA5PXT3P
YA5PXT4P
YA5PRA3P
YA5PRA4P
YA5MA110
YA5MA240
YA5ML
YA5MMS
YA5MW10
YA5MW15
YA5DL
YA5NL
YA5R1
YA5R2

Note: Shunt trips, UVT and auxiliaries - see common accessories page 104.

108

Circuit Protection Devices


Loadline Y6 Frame Moulded Case Circuit Breakers
Y6 Frame MCCBs

Exceeds the requirements of EN 60947-2


Rated insulation voltage 690V AC (Ui)
Electronic MCCBs have adjustable long, short and instantaneous trip functions
Electronic MCCBs are Category B rated for discrimination
Standard M12 cable termination = 240mm2
Extension terminal bars to be ordered separately when not used in conjunction
with Dorman Smith steel work - Y6XT4P (2 required)

Current rating (A)

3-pole cat. no.

4-pole cat. no.

Max.Min.

Y6 Frame Switch Disconnector


630
Y6B3P630D
800
Y6B3P800D
Y6 Frame MCCB Thermal/Magnetic Icu 50kA
400
250
Y6H3P400T5
630
400
Y6H3P630T5
800
500
Y6H3P800T5
Y6 Frame MCCB Thermal/Magnetic Icu 85kA

Y6B4P630D
Y6B4P800D

400
250
630
400
800
500
Y6 Frame MCCB Electronic Icu 50kA
630
315
800
400
Y6 Frame MCCB Electronic Icu 65kA

Y6K3P400T5
Y6K3P630T5
Y6K3P800T5

Y6K4P400T5
Y6K4P630T5
Y6K4P800T5

Y6H3P630E
Y6H3P800E

Y6H4P630E
Y6H4P800E

630
800

Y6J3P630E
Y6J3P800E

Y6J4P630E
Y6J4P800E

315
400

Y6H4P400T5
Y6H4P630T5
Y6H4P800T5

Dimensions
Y6

109

Circuit Protection Devices


Loadline Y6 Frame Accessories
Description
Terminal covers 3-pole
Terminal shroud (set of 1)
Interphase barriers (set of 2)
Terminal covers 4-pole
Terminal shroud (set of 1)
Interphase barriers (set of 3)
Terminations 3/4-pole
Cable clamps 2 x 185mm2 only
Locking devices
Dolly padlock device
Castell* lock (DS1 direct mounting)
Castell* lock (DS2 direct mounting)
Castell* lock door-mounted cam for shaft only
Shunt trips
Shunt 24V dc
Shunt 100-115V ac
Shunt 200-480V ac
Undervoltage release
UVR 24V dc
UVR 100-120V ac
UVR 200-240V ac
UVR 380-450V ac
Motors and interlocks
Motor actuator, 100-110V ac
Motor actuator, 200-240V ac
Changeover, rocker type
Changeover, manual slide type
Changeover, wire type with 1 metre cable
Changeover, wire type with 1.5 metre cable
Auxiliary switches
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary
Neutral link
Y6 Neutral link
Rotary handles
Standard length
Long length
Cover flange
Handle extension
*Castell is a trademark of Castell Safety International Limited.

110

Cat. no.

Y6TS3P
Y5TB3P
Y6TS4P
Y5TB4P
Y6CC4P
Y6DL
Y6CLDS1
Y6CLDS2
Y5DCLCAM
Y6ST24DC
Y6ST115AC
Y6ST480AC
Y6UVR24DC
Y6UVR120AC
Y6UVR240AC
Y6UVR450AC
Y6MA110
Y6MA240
Y6MR
Y6MMS
Y6MW10
Y6MW15
Y6AUX1
Y6AUX2
Y6AUXAL
Y6NL
Y6RH1
Y6RH2
Y5CF
Y6HE

Circuit Protection Devices


Loadline Y6 Frame Moulded Case Circuit Breakers
Changeover Units
The changeover pairs are four-pole units fitted with mechanical and electrical
interlocking mounted on a back plate. Both devices have a motor actuator and are
terminated for front access. All changeover pairs utilise the Y6 range of breakers.
Each breaker is fitted with:
1 - Shunt trip 240V AC - Electrical interlock
1 - AB auxiliary switch - to indicate MCCB status
1 - Alarm switch - for auto reset
1 - Motor operator spring charged 240V AC - to drive MCCB
1 - Mechanical interlock (rear)
Rating (A)

Cat. no.

400A
630A
800A

Y6AC400
Y6AC630
Y6AC800
Y Frame Changeover Unit

Remote Operation

Remote Operation

Changeover Unit Dimensions (mm)

111

Circuit Protection Devices


Loadline Y7 Frame Moulded Case Circuit Breakers
Y7 Frame MCCBs

Exceeds EN 60947-2 requirements


Rated insulation voltage 690V AC (Ui)
Electronic MCCBs have adjustable long, short and instantaneous trip functions
Electronic MCCBs are Category B rated for discrimination

Current rating (A)

3-pole cat. no.

4-pole cat. no.

Y7B3P1250D

Y7B4P1250D

Y7J3P1000E
Y7J3P1250E

Y7J4P1000E
Y7J4P1250E

Max.Min.
Y7 Frame Switch Disconnector
1250
Y7 Frame MCCB Electronic Icu 65kA
1000
500
1250
630

Y7 Frame Accessories
Description
Terminal covers 3-pole
Terminal shroud (set of 1)
Interphase barriers (set of 2)
Terminal covers 4-pole
Terminal shroud (set of 1)
Interphase barriers (set of 3)
Locking devices
Dolly padlock device
Castell* lock (DS1 direct mounting)
Castell* lock (DS2 direct mounting)
Castell* lock door-mounted cam for shaft only
Shunt trips
Shunt 100-120V AC
Shunt 200-480V AC
Shunt 24V DC
Under-voltage release
UVR 100-120V AC
UVR 200-240V AC
UVR 380-450V AC
UVR 24V DC
Motor actuators
Motor actuator 100-110V AC
Motor actuator 200-240V AC
Auxiliary switches 3-pole MCCB
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary
Auxiliary switches 4-pole MCCB
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary
Neutral link
Y7 neutral link
*Castell is a trademark of Castell Safety International Limited.

Dimensions
Y7

112

Cat. no.
Y7TS3P
Y5TB3P
Y7TS4P
Y5TB4P
Y7DL
Y7CLDS1
Y7CLDS2
Y5DCLCAM
Y7ST115AC
Y7ST480AC
Y7ST24DC
Y7UVR120AC
Y7UVR240AC
Y7UVR450AC
Y7UVR24DC
Y7MA110
Y7MA240
Y7AUX3P1
Y7AUX3P2
Y7AUX3PAL
Y7AUX4P1
Y7AUX4P2
Y7AUX4PAL
Y7NL

Circuit Protection Devices


Loadline Y8 Frame Moulded Case Circuit Breakers
Y8 Frame MCCBs

Exceeds EN 60947-2 requirements


Rated insulation voltage 690V AC (Ui)
Electronic MCCBs have adjustable long, short and instantaneous trip functions
Electronic MCCBs are Category B rated for discrimination

Current rating (A)

Type

Y8 Frame Switch Disconnectors


1600
Front terminals
1600
Rear terminals
1600
Draw out
Y8 Frame MCCB Electronic Icu 85kA
1600
Front terminals
1600
Rear terminals
1600
Ground fault

3-pole cat. no.

4-pole cat. no.

Y8B3P1600D
Y8B3P1600DR
Y8B3P1600DDO

Y8B4P1600D
-

Y8K3P1600E
Y8K3P1600ER
Y8K3P1600EG

Y8K4P1600E
N/A
N/A

Y8 Frame Accessories
Description

Cat. no.

Terminal covers 3-pole


Terminal shroud (set of 1)
Interphase barriers (set of 2)
Terminal covers 4-pole
Terminal shroud (set of 1)
Interphase barriers (set of 3)
Locking devices
Dolly padlock device
Castell* lock (DS1 direct mounting)
Castell* lock (DS2 direct mounting)
Castell* lock door-mounted cam for shaft only
Shunt trips
Shunt 100-120V AC
Shunt 200-480V AC
Shunt 24V DC
Under-voltage release
UVR 100-120V AC
UVR 200-240V AC
UVR 380-450V AC
UVR 24V DC
Motor actuators
Motor actuator 100-110V AC
Motor actuator 200-240V AC
Auxiliary switches 3-pole MCCB
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary
Auxiliary switches 4-pole MCCB
1AB auxiliary switch
2AB auxiliary switch
Alarm switch + 1 auxiliary
Neutral link
Y7 neutral link

Y7TS3P
Y5TB3P
Y7TS4P
Y5TB4P
Y7DL
Y7CL
Y7CLDS2
Y5DCLCAM
Y7ST115AC
Y7ST480AC
Y7ST24DC
Y7UVR120AC
Y7UVR240AC
Y7UVR450AC
Y7UVR24DC
Y7MA110
Y7MA240
Y7AUX3P1
Y7AUX3P2
Y7AUX3PAL
Y7AUX4P1
Y7AUX4P2
Y7AUX4PAL
Y7NL

*Castell is a trademark of Castell Safety International Limited.

Dimensions
Y8
MIN EARTHED BOUNDARY
H
L

MIN EARTHED BOUNDARY


4P

Extension handle
(removable)

H
L

H
L

Insulator

11

20

40.00

4P

Mounting angle

Mounting angle
15 max

30

100

3P

M8 Mounting screw

ASL

20
105

70

70

70

o12

15
70
20

85

17
140

175
o13

154

18

100

32
70

70

80

191

15 max

170

65
28

Conductor
overlap
max.

70

46
45

184
60

30

ASL
140

ASL

100

370

200

170

15

70.00

3P
Mounting hole

15

115
130

280

210
30.00

30.00

113

Circuit Protection Devices


Loadmaster Miniature Circuit Breakers
Loadmaster MCBs
Current rating (A)

1-pole cat. no.

3-pole cat. no.

10
20
30
40
50
60

LM10
LM20
LM30
LM40
LM60

LM3P20
LM3P30
-

Loadmaster Isolators
Current rating (A)

1-pole cat. no.

3-pole cat. no.

100

LW3

Loadmaster Accessories

114

Description

Cat. no.

Mounting bracket for MCB/isolator 2-pole


Mounting bracket for MCB/isolator 3-pole

LMMB2
LMMB3

Modular Devices
DSPM Range Surge Protector
DSPM Modular Series

Type 2; Class II device


DIN-rail mounted - EN50022
Replaceable plug-in modules
Protection status indication
IP20 ingress protection
Remote Indication option available

DSPM Surge Protectors

Widths (mm)

Cat. no.

40kA 1-phase with neutral/earth


40kA 1-phase with neutral/earth
& remote indication
40kA 3-phase with neutral/earth
40kA 3-phase with neutral/earth
& remote indication
40kA 1-phase
40kA 3-phase
MOV replacement plug-in SPM
MOV neutral/earth replacement
plug-in SPM

35
35

DSPM1PN
DSPM1PNR

70
70

DSPM3PN
DSPM3PNR

17.5
52.5
17.5
17.5

DSPM1P
DSPM3P
DSPML
DSPMNE

Dimensions

Surge handling capability (8/20s)


Surge protection technology
Nominal voltage rating
Max. continuous operating voltage
Frequency
Maximum current rating
Nominal discharge current, In (8/20s)
Max. surge current handling, Imax (8/20s)
Response time
Short-circuit withstand capability
Thermal overload protection
Nominal power consumption
Operating temperature
Protection at 5kA, Up (8/20s)
Protection at Imax (8/20s)
Replaceable modules
Protection status indication

Remote status indication option


Remote indication connections
Terminals
Remote signalling terminals
Module and base material
Device style
Category classification (EN 61643-11)
Protection rating

40kA
MOV
1-phase: 230V rms
3-phase: 415V rms
1-phase: 200-300V
3-phase: 380-515V
48-62Hz
Not applicable (parallel connected)
40kA
40kA
<10ns
40kA with max. backup fuse
(100A gL/gG)
120C
<10A
-40 to +70C
<1100V peak
<1600V peak
2 pin pluggable module
Mechanical flag mechanism:
Green: full protection
Red: no protection
Hard wired
Volt free N/O or N/C contacts
Base 16-35mm2
Remote 2.5mm2 Max.
230V rms 1A; 30V DC 2A
Flame retardant ABS
35mm2 DIN-rail mounted to EN 50022
SPD Type 2
IP 20

90 mm

Specification and Dimensions

17.5 mm

75 mm

115

Modular Devices
DSPE Range Surge Protector Series
DSPE 600 Series

Low let through voltage of 600 volts


Two stage (redundant) protection, with pre-failure indication
Site fault condition indicator
Remote Monitoring Unit is provided with a 1 metre cable and appropriate plug
and socket connectors (other lengths are available on request)
Easy installation and field serviceability
Compact size and small footprint

Dimensions

DSPM Surge Protectors

Cat. no.

30kA 2-stage, 3-pole surge protector


30kA 2-stage, 3-pole surge protector, remote terms & monitoring
30kA 2-stage, 3-pole surge protector with aux contact
Enclosure for DSP3 surge protection units
(240mm (h) x 190mm (w) x 90mm (d))

DSPE600
DSPE600R
DSPE600N
2IP-7-0244

Specification and Dimensions


Voltage rating (Nominal), Un
Max. continuous operating voltage, Uc

165,00

Maximum load current rating


Maximum surge current (8/20s), Imax
Response time
Power consumption (nominal)
Leakage current to earth
Terminals
Remote signalling terminals
10,00

116

177,00

186,50

70,00

Operating temperature
Light emitting diodes status indication

Case
Type (EN 61643-11)
Dimensions (mm) L
W
D
Weight (g)

400V rms
L-N 300V rms
L-L 500V rms
Unlimited (parallel connection)
30kA per phase
<10 ns
18mA per phase
600A
16mm2 max - line, neutral, earth
2.5mm2 max - remote signalling
Rated at 230V rms 0.2A or
30V DC 2A
-40 to +70 Celsius
Green: full protection
Red & green: reduced protection
Red - no protection
Steel - epoxy paint
2
176
110
72
1110

Modular Devices
DSPT Range Surge Protector Type 1
DSPT Type 1
Class 1; Type I device
Tested to withstand 10/350s waveforms

Description

Cat. no.

3-phase & neutral, 25kA L-N, 100kA surge protector

DSPT3PN

Specification and Dimensions


Max. continuous operating voltage (Uc)
Temporary overvoltage (Ut), L-N
Temporary overvoltage (Ut), N-PE
Response time L-N
Response time N-PE
Max. backup fuse
Max. backup fuse when V connected
Short-circuit withstand capability
at max backup fuse (Ip)
Lightning impulse current,
10/350s, L-N (Iimp)
- Charge (Q)
- Specific energy (W/R)
Lightning impulse current,
10/350s, N-PE (Iimp)
- Charge (Q)
- Specific energy (W/R)
Total lightning current, 10/350s
(Itotal), L1,L2,L3,N-PE
Max. discharge current, 8/20s (Imax), L-N
Max. discharge current, 8/20s (Imax), N-PE
Nominal discharge current, 8/20s (In)
Voltage protection level at Iimp (Up)
Weight (g)

275V ac rms
335V/5s
1200V/0.2s
<25ns
<100ns
315A gL/gG
63A gL/gG
80ka rms

Dimensions

25kA
12.5As
156kJ/
100kA
50As
2500kJ/
100kA
120kA
120kA
50kA
<1.3kV
1125

117

Modular Devices
Switch Disconnectors, Timers, Modular Contactors
Exceeds the requirements of EN 60947-3
50mm2 cable capacity
Duty category of AC22

Current rating (A)

Poles

Max. cable (mm)

Cat. no.

63
63
63
100
100
100
125
125
125

2
3
4
2
3
4
2
3
4

50
50
50
50
50
50
50
50
50

AV263
AV363
AV463
AV2100
AV3100
AV4100
AV2125
AV3125
AV4125

Modular Programmable Timers


Daily/weekly
2 relays
16A

Current rating (A)

Width (mm)

Function

Cat. no.

16A (AC7A)

1 or 2 channel

35

DRT-DW2R

Modular Contactors
Exceeds the requirements of EN 61095
May require de-rating when used with inductive loads
see Contactor De-rating table in the Technical Applications section
Current rating (A)

Width (mm)

Contacts

Cat. no.

20A
20A
25A
25A
40A
40A
63A
63A
Venting kit *

17.5
35
35
35
54
54
54
54
9

2P N/O
2P N/C
4P N/O
4P N/C
4P N/O
4P N/C
4P N/O
4P N/C
-

EE2P20CO
EE2P20CC
EE4P25CO
EE4P25CC
EE4P40CO
EE4P40CC
EE4P63CO
EE4P63CC
LLMV

* Ventilation module must be fitted between alternate pairs of contactors


to prevent overheating.

118

Modular Devices
Current Transformers
Measuring Current Transformers

For use with kilowatt hour metering


Up to Class 0.5 accuracy
System voltage up to 720V
Secondary output 5A
Operating temperatures from 20C to +70C
Current
rating (A)

Cable aperture Height


(mm)
(mm)

Width
(mm)

Cat. no.

100
125
30
60
100
125
200
250
400
600
800

25
25
0.68
0.68
25
25
25
25
32
42
63

45
45
50
50
50
50
50
50
60
90
134

M53Q-100/5
M53Q-125/5
M55E-30/5
M55E-60-5
M53J-100/5D
M53J-125/5D
M53J-200/5D
M53J-250/5D
M63N-400/5
M93L-600/5
MB5D-800/5

65
65
80
80
80
80
80
80
94
131
156

M30-DINCLIP

DIN-rail mounting option for M63N/M93L current transformers


(2 required)

M50-DINCLIP

DIN-rail mounting option for MB5D current transformers


(2 required)

Dimensions
M53Q

M55E

M53J

MBD5

M63N

M93L

119

Modular Devices
3-in-1 Current Transformers
3-in-1 Current Transformers

For use with metering


Space saving 3-in-1 design
Up to 5A class
Secondary output 5A
Plug-in metal feet, DIN-rail clips and busbar mounting options supplied as standard

Part number

Ratio

Burden VA against
class index
Class
Class
Class
0.5
1
3

Aperture
(mm)

M3N1-25-60/5

60/5

3@15 x 25mm

M3N1-25-100/5

100/5

1.5

2.5

3@15 x 25mm

M3N1-25-125/5

125/5

1.5

2.5

3@15 x 25mm

M3N1-25-160/5

160/5

1.5

1.5

2.5

3@15 x 25mm

Part number

Ratio

Burden VA against
class index
Class
Class
Class
0.5
1
3

Aperture
(mm)

M3N1-35-100/5

100/5

1.5

3@21 x 25mm

M3N1-35-125/5

125/5

1.5

2.5

3@21 x 25mm

M3N1-35-160/5

160/5

1.5

1.5

2.5

3@21 x 25mm

M3N1-35-200/5

200/5

1.5

1.5

2.5

3@21 x 25mm

M3N1-35-250/5

250/5

1.5

1.5

2.5

3@21 x 25mm

Part number

Ratio

Burden VA against
class index
Class
Class
Class
0.5
1
3

M3N1-45-250/5

250/5

1.5

1.5

2.5

3@31 x 31mm

M3N1-45-300/5

300/5

2.5

2.5

3.75

3@31 x 31mm

M3N1-45-400/5

400/5

2.5

2.5

3.75

3@31 x 31mm

M3N1-45-500/5

500/5

2.5

2.5

3.75

3@31 x 31mm

M3N1-45-630/5

630/5

2.5

2.5

3.75

3@31 x 31mm

Aperture
(mm)

Dimensions
M3N1-25

120

M3N1-35

M3N1-45

Modular Devices
Split Core Current Transformers
A range of split core current transformers that offers a cost
effective and efficient method by which the current can be
measured without the need to break the conductor, thereby
reducing installation and commissioning time.

Case 4

Case 3

Case 2

Case 1

Accuracy Class
Part number

Ratio

Burden VA against class index


0.5

SC1-100/5A
SC1-150/5A
SC1-200/5A
SC1-250/5A
SC1-300/5A
SC1-400/5A
SC2-250/5A
SC2-300/5A
SC2-400/5A
SC3-250/5A
SC3-300/5A
SC3-400/5A
SC3-500/5A
SC3-600/5A
SC3-750/5A
SC3-800/5A
SC3-1000/5A
SC4-500/5A
SC4-600/5A
SC4-750/5A
SC4-800/5A
SC4-1000/5A
SC4-1200/5A
SC4-1250/5A
SC4-1500/5A
SC4-1600/5A

100/5A
150/5A
200/5A
250/5A
300/5A
400/5A
250/5A
300/5A
400/5A
250/5A
300/5A
400/5A
500/5A
600/5A
750/5A
800/5A
1000/5A
500/5A
600/5A
750/5A
800/5A
1000/5A
1200/5A
1250/5A
1500/5A
1600/5A

1.5
2.5
1
1.5
1.5
1
1.5
1.5
2.5
2.5
3
3
5
2.5
3
5
6
7.5
8
8

1.5
2
4
6
2
3
3
2
3
3
5
5
6
7.5
10
4
5
6
7.5
10
12.5
15
17
17

1.5
2
2.5
4
6
10
4
6
10
4
6
10
15
15
20
20
20
12.5
15
17.5
20
20
25
30
30
30

Aperture
(mm)
20 x 30
20 x 30
20 x 30
20 x 30
20 x 30
20 x 30
50 x 80
50 x 80
50 x 80
80 x 80
80 x 80
80 x 80
80 x 80
80 x 80
80 x 80
80 x 80
80 x 80
80 x 120
80 x 120
80 x 120
80 x 120
80 x 120
80 x 120
80 x 120
80 x 120
80 x 120

Dimension

Case 1

Case 2

Case 3

Case 4

A
B
C
D
E
F
G
H
I
Weight (Kg)

20
30
51
89
111
34
47
40
32
0.75

50
80
78
114
145
32
32
32
33
0.90

80
80
108
144
145
32
32
32
33
1.05

80
120
108
144
185
32
32
32
33
1.25

Dimensions

Units of measurement mm

121

Earth Leakage Relay


DIN-rail Mounted

Precision digital protection relay


Adjustable sensitivity of 30mA to 10A
Adjustable time delay from 0 to 10 seconds
Double-pole relay contacts 8A, 250V
Supply voltage 100-250V AC/DC (50/100Hz)

Frequency (Hz)
50

Auxiliary supply (V)

Cat. no.

100-250 AC/DC

ELR1

Specification
Measuring input
Overload
Frequency
Auxiliary voltage
Auxiliary burden
Trip current settings

Connections
The equipment grounding
conductor must bypass the CT

Trip accuracy
Trip response time
Time delay set points

Fused
Auxiliary
supply

Indication
Remote
reset
switch

Relay contacts

Relay contact rating


GND

Relay mechanical life


Analogue output
Enclosure style
Compliant with
Link to energise
on trip
Commissioning
Meter
Relay 1 Relay 2

Material
Terminals
Operating temperature
Storage temperature
Relative humidity
Weight
Dimensions

From core balanced current transformer


20 x nominal for 1 second
50Hz or 60Hz 10%
100-250V ac and dc
Less than 1.5 Watts
Selectable 30mA, 100mA, 200mA, 300mA, 500mA,
1A, 2A, 3A, 5A, 10A
50% <trip point current
<100% in accordance with IEC 1543
<40ms (at 5 x rated trip current, ignoring the
selected time delay)
Selectable 0ms, 50ms, 100ms, 150ms, 200ms,
300ms, 400ms, 500ms, 600ms, 700ms, 800ms,
900ms, 1 second, 2 seconds, 5 seconds, 10 seconds.
When 30mA leakage is selected, the time delay is
disabled
5 yellow LED bar graph for leakage levels
Red LED indicated trip function
Green LED indicated auxiliary power presence
Red LED pre-alarm indication (SPCO version only)
Standard: 2-pole change over
Option: 2 1-pole change over (pre-alarm and
main alarm)
8 amps at 250V ac
8 amps at 30V dc resistive
>100,000 operations
0 to 1mA = 0 to 100% of selected tripping level.
Compliance 1V, accuracy 10%
DIN 43880, rail width 70mm
EMC and LVD, UL 3111-1 File No: E203000, CSA
22.2/1010.1-92 BSEN 50081-1, BSEN 50082-2, IEC
60255-22-1 (BS5992), IEC 60255-11, BSEN 61543 (IEC
1543), BSEN 61010 (IEC 1010), EN 60068 (IEC 68)
Flame retardant UL94V0
1 to 4mm2 solid or stranded conductors.
IP20 protection
10C to +60C
20C to +70C
<95% non condensing
<250g
71mm wide x 90.5mm high x 73mm deep 2.79" wide
x 3.56" high x 2.87" deep

Dimensions

33.0mm 1.3"
48.0mm 1.89"

90.5mm
3.56"

2.46"

62.5mm

122

46.0mm
1.87"

71.0mm
2.79"

110.0mm 4.32"

73.0mm 2.87"

Modular Devices
Core Balance Current Transformers
Core Balanced Current Transformers

For use with ELR1 earth leakage protection relay


Leakage measurement range 0 to 10A
Integral wire-sealable terminal cover
Flame retardant, high impact moulded case
Current
rating
(A)

Dim E
Aperture
(mm)

Dim A
Width
(mm)

Dim B
Height
(mm)

Dim C
Depth
(mm)

Dim D

Cat. no.

250
630
1000
1000

35
70
105
140

100
130
170
220

79
110
146
196

26
32
38
49

48.5
66
94
123

CBT-94F-035
CBT-94F-070
CBT-94F-105
CBT-94F-140

Specification
System voltage
Test voltage
System frequency
Primary ratings
Secondary terminals
Operating temperature
Enclosure
Compliant with
Mounting hardware

720V maximum
3kV ac for 1 minute
50Hz or 60Hz
From 30mA to 10A
Protected to IP20
10C to +50C
UL94V0 flame retardant plastic
IEC185, VDE 0414
Steel mounting feet for wall or base mounting

Dimensions
A

33

46

C
E

123

Modular Devices
Integra Ci1 Energy Meter
The Integra Ci1 energy meter is specially designed and developed
as a cost effective Watt hour and VAr hour meter to complement
the current Integra Ci digital metering system (dms). The Integra
Ci1 self-contained 96mm DIN panel mounted Watt hour, VAr hour
meter measures the real consumption of active and reactive
energy to Class 1.0 accuracy.
The backlit LCD screen displays 8 character counter indicating Watt hour or VAr
hour units. The optional modules enables transfer of energy measurements to
building management systems (BMS) via pulsed or digital communication options.

Programmable Functions
Integra Ci1 meter provides simple programming to suit single phase 2-wire, threephase three wire and three-phase four-wire un-balanced system configurations,
CT ratio settings and configuration of selected communication options. To prevent
unauthorised access to the product configuration settings, all set-up screens
offer password protection.

Display
Direct access to display the programmed set CT ratio, Watt hours import and
export, VAr hours import and export and the phase sequence test routine for both
voltage and current phases. During the accumulation of the Wh or VArh the
running icon will flash at a rate dependant on the displayed parameter.

Plug-in Modules
Plug-in modules allow to fit either maximum of two isolated pulsed output relays
or a RS485 communication module and one isolated pulsed output relay. The
communication output module can be programmed internally to respond either to
Modbus RTU or Johnson Controls protocols.

Panel Mounting
Integral retention clips allow fast, safe and secure panel mounting in various
material thicknesses without the need for external screws or clips.

Product Code

Parameters
Button

Screen

Parameters

CT

CT ratio

Wh

2
3

IMPORT Wh
EXPORT Wh

VArh

4
5

IMPORT VArh
EXPORT VArh

TEST

Phase sequence
diagnostic

Description

Part number

Integra Ci1 base unit with pulse output

CI1-01-PUL

Options
Optional plug-in pulse output module
Optional RS485 Modbus plug-in module

CI-PUL-01
CI-MOD-01

Accessories
IP65 protective cover
IP54 panel gasket

3G36502
3C34501

Dimensions
77.50
53.00

Running icon indicates Wh


and VAhr accumulation.

124

Modular Devices
Integra Ci3 Digital Metering System
The Integra Ci3 digital metering system (dms) represents the first
model of a new generation of digital metering systems designed
to complement the current Crompton Instruments Integra series.
The Integra Ci3 meter is an accurate and cost effective solution
for measurement and display of all major electrical and power
quality parameters.
Designed, developed and manufactured in the UK, the Integra Ci3
dms builds on Crompton Instruments long established reputation
for metering product quality.
The product features a DIN 96 panel mounted enclosure, backlit LCD screen and
user programmable CT ratios, all accessible via an intuitive user interface. Integra
Ci3 dms measures 17 electrical parameters including total harmonic distortion
(THD) up to the 31st harmonic.

Programmable Functions
Integra Ci3 dms is programmable to suit single-phase two-wire, three-phase
three-wire and three-phase four-wire system configurations. Programmable CT
ratios enable to display any current range.

Display
The parameters can be viewed on a backlit LCD screen. The 15 screens are
accessible via four buttons on the front panel allowing to scroll between various
screens making the navigation very user-friendly, intuitive and above all simple.

Plug-in Modules
Integra Ci3 dms offers two output ports at the rear of the product, to allow the
fitting of either two isolated pulsed output relays or a RS485 communication
module such as Modbus or Johnson Controls communication output. These are
configurable via internal settings.

Parameters
Button
V/Hz

Panel Mounting
Integral retention clips allow fast, safe and secure panel mounting in various
material thicknesses without the need for external screws or clips.

Screen

Parameters

Volts L1 - N
Volts L2 - N
Volts L3 - N
Volts L1 - L2
Volts L2 - L3
Volts L3 - L1
Frequency
Volts L1 - N THD%
Volts L2 - N THD%
Volts L3 - N THD%
Volts L1 - L2 THD%
Volts L2 - L3 THD%
Volts L3 - L1 THD%

3
4

Product Code
Description

Part number

Integra Ci3 base unit with pulse output

CI3-01-PUL

Options
Optional plug-in pulse output module
Optional RS485 Modbus plug-in module

CI-PUL-01
CI-MOD-01

Accessories
IP65 protective cover
IP54 panel gasket

3 G365 02
3 C345 01

2
3

Dimensions
4

77.50
53.00

P/PF

Current L1
Current L2
Current L3
Neutral current
L1 Current max
Demand
L2 Current max
Demand
L3 Current max
Demand
Neutral current max
demand
Current L1 THD%
Current L2 THD%
Current L3 THD%

2
3

kW
kVAr
kVA
kW Max demand
Power factor

1
2

kWh
kVArh

125

Modular Devices
Integra 1630 Digital Metering System
Multi-function Integra 1630 digital metering system provides high
accuracy 0.2% measurement, display and communication of all
major electrical and power quality parameters including total
harmonic distortion (THD) up to the 31st harmonic. To suit user
requirements, the range includes single-phase, three-phase
three-wire and three-phase four-wire capability, all selectable
at the point of installation.
Features
Auxiliaries: 100/250V ac/dc (12/48V dc optional)
Options: ProfibusTM, Modbus TCP, Bacnet IP, RS485, Pulsed output

Product Description and Order Codes

Measured Parameters
System (average) volts
System (average) current
System (total) kW
System volts (average) THD%
System current (average) THD%
Phase neutral
Voltage (VL-N)
(4 wire only)
Phase phase
Voltage (L-L)
(3 wire only)
Voltage THD%
(4 wire only)
Phase current
Current THD %
Neutral current
(4 wire only)
Frequency
Power factor (overall)
kVAr kVA kW
kWh import (7-digit resolution)
kVArh import (7-digit resolution)
kWh export (7-digit resolution)
kVArh export (7-digit resolution)
kW demand
Current demand
Maximum kW demand
Maximum current demand
Hours run

Modbus, ProfibusTM and Bacnet are


trademarks

126

Description

Cat. no.

1-phase, 3-phase 3/4-wire,


241-480V L-L, 5A CT input, Aux.
100-250V ac/dc

INT-1630-M-5-M-option

Options
No options
1 pulsed output
RS485 interface Modbus +
1kWhr pulsed output
Extended collar

Dimensions

000
100
110
OPT-1630-collar

Modular Devices
Modular Devices Kilowatt Hour Energy Meters DIN-rail
Self-contained energy metering system which is ideal for
switchgear, plant instrumentation and process control. The range
has significant advantages over the traditional energy meters with
pulsed outputs, communications and direct connection all
available as options.

Description

Cat. no.

Single-phase: 230V CT Connected 5A


1-phase CT 5A pulse output
DRK-1PCT-240
Pulsed output (Opto),
Mechanical counter
Three-phase: 400V (+N) CT Connected 5A
3-phase 3 or 4-wire system,
DRK-3PCT-415
5A CT connected, pulsed output
(Opto), mechanical counter
3-phase 3 or 4-wire system,
DRK-3PCT-415-LCD
5A CT connected, pulsed output
(Opto), LCD screen
Single-phase: 230V Direct Connected 63A
1-phase 230V63A direct
DRK-1P-230-D63
connected, pulsed output (Opto)
LCD screen
Three-phase: 230V (400V) Direct Connected 100A
3-phase 230V L-N (400V L-L)
DRK-3P-400-D100
100A direct connected,
pulsed output (Opto), LCD screen

Dimensions
DRK-1PCT-240

DRK-1PCT-230-D63

DRK-3PCT-415/
DRK-3PCT-415-LCD

DRK-3PCT-400-D90

127

Modular Devices
Integra Ri3 Digital Metering System
The product features a DIN-rail enclosure, backlit LCD display and
user programmable CT ratios, all accessible via an intuitive user
interface. Integra Ri3 dms measures 17 electrical parameters
including total harmonic distortion (THD) measurement up to the
31st harmonic.
Specifications
Input
Nominal input voltage
Max. continuous input
overload voltage
Max. short duration input voltage
Nominal input voltage burden
Nominal input current
Max. continuous input
overload current
Max. short duration input current

Features

DIN-rail enclosure DIN 43880


Backlit LCD screen
Programmable CT ratio
True rms measurement
User programmable
system configuration
Pulsed output and Modbus
as standard

Nominal input current burden


Frequency
System CT primary values
Auxiliary
Operating range

Benefits

Cost effective
Simple navigation
Crompton renowned quality
UK manufactured

35.00

45.00

62.00

Dimensions

32.40
48.30

62.00

128

Burden
Accuracy
Voltage (V)
Current (A)
Neutral current calculated (A)
Frequency (Hz)
Power factor (PF)
Active power (W)
Reactive power (VAr)
Apparent power (VA)
Active energy (kWh)
Reactive energy (kVArh)
THD
Response time
Output
Pulse output relay
Contact rating
Type
RS485 Modbus output module
Type
Baud rate
Enclosure
Enclosure style
Dimensions
Front protection rating
Case protection rating
Material
Weight
Terminals
Environment
Operating temperature
Storage temperature
Relative humidity
Shock
Vibration
Dielectric voltage

100-289V AC L-N (173-500V AC L-L)


120% of nominal
2 x range maximum (1 second application
repeated 5 times at 5 minute intervals)
< 0.2VA per phase
5A AC rms
120% of nominal
10 x nominal (1 second application repeated
5 times at 5 minute intervals)
< 0.6VA per phase
45-66Hz
1 to 9999
110-400V AC nominal +/-10% (99-440V AC
absolute limits) or 120-350V DC +/-20%
(96-420V DC absolute limits)
< 10VA/5W
0.5%
0.5%
4%
0.1 Hz
1% of unity
+/- 1% of range
+/- 1% of range
+/- 1% of range
Class 1 (IEC 62053-21)
+/- 1% of range
1% up to 31st harmonic
1sec
1
50mA max at 250V AC
Solid state relay
1 Modbus channel
2-wire half duplex
2400, 4800, 9600, 19200, 38400
DIN-rail
72x90mm (width x height) as per
DIN 43880
IP52
IP30
Polycarbonate to UL94V0
300g
Shrouded screw-clamp 0.05-4mm wire
-10C to +55C
-20C to +70C
0-90% non-condensing
30g in 3 planes
10Hz to 50Hz
Withstand test 3.25kV rms 50Hz for 1
minute between comms and measuring
inputs, comm and aux, aux and measuring
inputs

Section

MCB and MCCB General


Purpose Enclosures

General Purpose Enclosures


General Purpose MCB/Modular Units Enclosures
1

Construction

Picture

Number
of ways

HxWxD
(mm)

Weight
(kg)

Cat. no.

Sheet steel
Insulated, IP4X
Insulated, IP4X
Insulated, IP4X
Insulated, IP55
Insulated, IP55

1
2

6
2
4
8
5
8

225x134x73
130x50x60
130x86x60
162x214x92
175x125x115
175x214x115

1.0
0.1
0.2
0.6
0.5
0.8

LLMGPS6S
LLMGPI2
LLMGPI4
LLMGPI8
LLMGPW5
LLMGPW8

3
4

General Purpose MCCB Enclosures 16-250A


Accepts all YA3 devices up-to 250A (as per page 107)
IP4X rated
Spreading room for 150mm2

Construction

Device
type

HxWxD
(mm)

Weight
(kg)

Cat. no.

Sheet steel - surface

YA3

687x263x120

16

LLGPYA3

Note: LLGPYA3 requires neutral link YA3NL to be ordered separately.

General Purpose MCCB Enclosures 400A-800A

Accepts all YA5 & Y6 devices up-to 800A (pages 109 and 111)
IP4X
Neutral link included
Spreading room for 240mm2

Construction

Device
type

HxWxD
(mm)

Weight
(kg)

Cat. no.

Sheet steel

YA5/6

1060x420x175

16

LLGPYA56

Note: For terminating two parallel cables with YA5 frame please order extension
terminals (YA5XT3P) separately.

Dimensions

130

Section

Technical Data & Applications

132

Technical Data & Applications


Index
Compliance with International Standards

134

Standard Terminology

135

Current Carrying and Switching Devices

137

Miniature Circuit Breakers (MCBs)

140

Residual Current Circuit Breakers (RCCBs)

145

Modular Contactors

147

Moulded Case Circuit Breakers (MCCBs)

151

Motor Starting Applications (MCCBs)

152

Discrimination and Cascading

153

System Sizing and Diversity

160

Prospective Short-circuit Current

161

Earth Fault Protection including MCCB Max Zs

164

Forms of Separation

167

Ingress Protection

169

Loadline MCCB Insulation Data

170

Loadline YA2 Frame MCCB Characteristics

171

Loadline YA3 Frame MCCB Characteristics

172

Loadline YA5 and Y6 Frame MCCB Characteristics

173

Loadline Y7 and Y8 Frame MCCB Characteristics

174

133

Compliance with International


Standards
Dorman Smith branded products comply with internationally recognised technical
and quality standards to ensure that each product is fully capable of meeting the
relevant standard requirements for its intended use.
The design, manufacture, procurement, supply and servicing of Dorman Smith
branded products is also governed by compliance to an international standard
through the operation of a Quality Management System.
Quality Management System

BS EN ISO 9001:2008

The Institute of Electrical Engineers (IEE) British Standard BS 7671 addresses


Requirements for Electrical Installations and dictates that all relevant products must
comply with applicable British, International or Harmonised Standards according to
the intended installation and application of the equipment. The BS 7671 document
is commonly referred to as The Wiring Regulations.
Products are type tested, manufactured, routinely tested and assembled in
accordance and compliance with a number of relevant Harmonised Standards
recognised by the electrical industry.
A Harmonised Standard is a European Standard formally presented by the
European Committee for Electrotechnical Standardisation, CENELEC, to the
European Commission and published in its official journal. These documents are
denoted by the prefix EN (European Norm).
The products listed within this catalogue conform to appropriate electrical and
mechanical standards as follows:

MCB Distribution Boards


Panel Boards
MCBs
MCCBs
Switches
RCCBs
RCBOs
Contactors

EN
EN
EN
EN
EN
EN
EN
EN

60439-3
61439-2
60898
60947-2
60947-3
61008
61009
61095

In addition to the above, and where appropriate, Dorman Smith branded products
also comply with the relevant requirements of the standard for protection against
physical, mechanical and liquid ingress as follows:
Ingress Protection

134

EN 60529

Standard Terminology
The Harmonised Standard EN 60898 and the IEE Wiring Regulations BS 7671:2008
contain references to a set of adopted standard terminology for the principal
device parameters with regard to MCBs. This terminology is also embraced by
other standards with regard to MCCBs and switches (EN60947-2 and EN 60947-3).
The standard terminology relates to the following parameters:
Rated
Rated
Rated
Rated
Rated
Rated

Operational Voltage, Ue
Insulation Voltage, Ui
Current, In
Short Circuit Capacity, Icn
Service Short Circuit Breaking Capacity, Ics
Ultimate Breaking capacity, Icu

Rated Voltage and Current


Rated Operational Voltage, Ue
The nominal voltage of the system should not exceed the stated value of Ue.
For example: single-pole Ue = 230/400V, three-pole Ue = 400V.
The standardised values of 230V and 230/400V will progressively replace 240V,
220/380V and 240/415V.

Rated Insulation Voltage, Ui


This is the voltage upon which the dielectric properties are based, using tests at
high voltage and mains frequency.
Unless otherwise stated, the rated insulation voltage is the value of the maximum
rated voltage of the circuit breaker.
In no case shall the maximum rated voltage exceed the rated insulation voltage.

Rated Current, In
This is the current that the circuit breaker will carry continuously under specified
conditions and upon which the time/current characteristics are based.
Unless otherwise stated, this value is based upon a reference ambient temperature
of 30 degrees Celsius.
EN 60898 Standard refers to the following terms:

Short Circuit Capacity


Rated Short Circuit Capacity, Icn
The calculated prospective fault current at the incoming terminals of the
circuit breaker should not exceed the stated value. For example: Icn = 10kA
(marked 10000).

Service Short Circuit Breaking Capacity, Ics


This value is the maximum level of fault current operation, after which further
service of the device is assured without loss of performance. Note that there is no
requirement for Ics to be marked on the device.
There is a proscribed relationship between Ics and Icn, as follows:
For values of Icn up to 6000A
Ics = Icn
For values of Icn 6000A to 10000A
Ics = 0.75Icn (but with a minimum value
of Ics = 6000A)
For values of Icn above 10000A
Ics = 0.5Icn (but with a minimum value
of Ics = 7500A)

135

The EN 60947-2 and EN 60947-3 Standards also refer to the following terms.

Isolation Suitability
These define the requirements for the suitability of circuit breakers to perform
isolation duty by defining tests to which such units must comply. Conforming
devices must carry a standard symbol mark to show that they are suitable for
isolation duty. For example, all Dorman Smith circuit breakers are so marked.

Utilisation Categories
The utilisation category of a circuit breaker is stated with reference to whether
or not it is specifically intended for discrimination by means of an intentional time
delay with respect to other circuit breakers in series on the load side under
short-circuit conditions.

Category A
This designates circuit breakers not specifically intended for selectivity with devices
on the load side. Circuit breakers will discriminate only up to certain fault levels,
above which discrimination with devices on the load side cannot be guaranteed.

Category B
This designates circuit breakers specifically intended for selectivity with devices on
the load side. Such circuit breakers will incorporate some form of time delay.
EN 60947-2 recognises both a rated service and a rated ultimate short circuit
breaking capacity for both Category A and Category B circuit breakers.

Rated Service Breaking Capacity, Ics


In order to define this value, the circuit breakers under test must be subjected to a
test sequence of:
Ics = o t co - t co, where:
o = opening time under fault conditions
t = time interval before re-closing (not more than 3 minutes)
c = closing operation on to a fault
After this test sequence, dielectric, terminal temperature and over-current tests are
to be applied. The circuit breaker must meet certain test parameters to ensure that
the device has not deteriorated in performance and can be put back into service.

Rated Ultimate Breaking capacity, Icu


In order to define this value, the circuit breakers under test must be subjected to a
test sequence of:
Icu = o t co.
After this test sequence, dielectric and over-current tests are to be applied.
The rated service breaking capacity (Ics) applies to short circuit faults that could
occur in practice; whereas the ultimate short circuit capacity (Icu) is the maximum
theoretical fault value of the installation at the point of connection.
The standard defines the ratio between the two values. Ics will be shown as 25%,
50%, 75% or 100% of its Icu value for Category A devices and 50%, 75% or 100% of
Icu for Category B devices.
A circuit breaker can remain in service after interrupting a short circuit up to its
rated value of Ics. However, where two or more faults occur between the Ics and Icu
values, the capability of the device for continued operation must be verified.

136

Current Carrying and


Switching Devices
Switch
A switch is a mechanical device capable of making, carrying and breaking current
under normal circuit conditions.

Disconnector (Isolator)
A disconnector is a mechanical switching device that provides the function of
circuit isolation.

Switch Disconnector
This device combines the functionality of the two foregoing devices; it provides
making, carrying, breaking and isolation of current within a circuit.

Fuses
Fuses can be combined with any of the above devices in any physical order. The
inclusion of a fuse will add the functionality of short circuit protection, breaking the
circuit when the current flow is higher than that for which the circuit is rated.

Combination Devices
In order to enhance circuit protection, switches and fuses are often combined
within a single device. The physical composition of the device can be identified by
the literal position of the words in its description. For example, the word fuse at
the beginning of the device description identifies the fuse as forming part of the
moving contact system, whereas placing it at the end of the description identifies
the fuse as a static link.

Functional Summary
Term

Features
provided

Features
not provided

Switch

Current rating
Operational and insulation
voltage
Making and breaking of load
Short time current rating
Current rating
Isolation
Operational and insulation
voltage
Short time current rating
Overload protection
Short circuit protection

Isolation

Disconnector

Fuse

Protection

Protection
Making/breaking capability

Switching

Suitability for Purpose


All of these devices have the ability to carry rated current either continuously or
for a period of eight hours under defined conditions. Selection and specification of
a specific device depends upon the circuit application.

137

Function

Switching Applications
For switching applications, the principal functions and capabilities include:
Making and breaking operation
A switch must have the ability to make or break defined load and overload
currents at a rated operational voltage, for the useful life of the device.
Short circuit action
The device must have the capability of handling short circuit current and/or
through fault and/or fault making.
Protection
The device must interrupt the circuit under overload and/or short circuit
conditions.
Isolation
To meet this requirement, the device must ensure disconnection of the supply for
safe downstream working. Facilities must be included for safety padlocking in the
off position, together with positive indication of the contact position.
Neutral switching
Where the neutral is reliably earthed, it is accepted that the neutral need not be
switched except in defined circumstances (e.g. the incoming switch disconnector
in a consumer unit) even though the Wiring Regulations (BS 7671:2008) class the
neutral as a current carrying conductor.
In applications where the neutral cannot be confirmed as reliably earthed, the
neutral should be switched simultaneously with the phase(s) or alternatively
arranged to make before and break after the phase(s).

Fuse Combination Unit

138

Utilisation Category
The utilisation category defines the basic circuit conditions and the switching
capability of the device.

Category

Circuit/application

AC20/DC20

Connecting and disconnecting under no load.


Assumes all switching operations are carried out by other
capable devices before this device is operated.
Switching of resistive loads including moderate overloads.
Suitable for purely resistive type loads.
Device can switch 150% of its rated current under
fault conditions.
Switching of mixed resistive/inductive loads, including
moderate overloads.
Suitable for mixed resistive/inductive loads.
Device can switch 300% of its rated current under
fault conditions.
Switching of highly inductive loads.
These devices are provided principally as back-up to other
means of switching, e.g. contactors. In the event of failure of
the functional device, the AC23/DC23 device can safely
interrupt a stalled motor current. Where devices are the
only means of controlling individual motors they should
comply with the requirements of Appendix A of the
EN 60947-3 standard.

AC21/DC21

AC22/DC22

AC23/DC23

Note: Switch disconnectors for AC21/DC21, AC22/DC22 and AC23/DC23 categories


also have to meet the requirements of AC20/DC20.
For specific and special applications such as switching of capacitors and tungsten
lamps not covered by the EN 60947-3 standard, the manufacturers advice should
be sought.

Frequent and Infrequent Use


The designation A or B should be appended to utilisation categories to indicate
the suitability for frequent or infrequent use in service. The Rule of Thumb
definition for full load current switching duty is:
Frequent (A): Up to five times a day for small devices, say up to 100 amps, and
once per week for larger devices.
Infrequent (B): One per week for the smaller devices and once per month for the
larger devices.

139

Miniature Circuit Breakers (MCBs)


In general terms, circuit breakers are thermal/magnetic electromechanical devices
that provide current making, carrying and breaking functions and will trip to
interrupt a circuit under abnormal conditions. MCBs are equipped with positive
contact indication flags: red indicates that the contact(s) are closed, green
indicates the open state. The contact(s) will open when tripped due to abnormal
circuit conditions or can be manually put into the open state by use of a handle.
These devices are used to provide protection and control of circuits against
overload and short circuit conditions. Dorman Smith MCBs are supplied with
various breaking capacities, particularly for ratings of 6kA and 10kA. The lower
rated devices are used typically in domestic installations, e.g. in consumer units,
whereas the higher rated devices are suitable for a range of commercial and
industrial circuit protection applications.
The thermal and magnetic trip functions cater for different circuit abnormalities and
operate as follows:

Thermal Trip Function


The purpose of this form of protection is to interrupt the circuit upon sensing an
overload current. Typically, a bi-metallic strip is used such that it will deflect due to
differential expansion of the dissimilar metals in response to the heating effect
caused by the passage of current through it. The higher the current, the greater will
be the heating effect and the more the deflection. At a preset point the physical
deflection will be sufficient to actuate the tripping mechanism, opening the
contact(s) and interrupting the circuit.

Magnetic Trip Function


The purpose of this form of tripping is to protect against the effects of short circuit
fault currents. A wire coil or solenoid is used to provide this function, operating the
trip mechanism when the over-current reaches a preset magnitude. As the fault
current rapidly increases, the magnetic field also increases, energising the coil and
moving a cam that is part of the contact assembly to fully open the contact(s)
thereby interrupting the circuit.

Characteristics
MCBs are designed according to one of three distinct tripping characteristics
designated B, C or D. These designations relate to the magnetic trip setting and
indicate the multiple of nominal current that will be tolerated by the device before
tripping. The following table illustrates these characteristics with typical duties and
applications. The nominal rated current is denoted by the symbol In.

140

Type

Magnetic
trip

Application

B
C
D

3-5 In
5-10 In
10-20 In

Light duty, resistive loads


Fluorescent lights, small motors, inductive loads
Sodium lights, large motors (>3kW), large
inductive loads

MCB Tripping Characteristics B, C and D Types

B
C
D

The tripping time for the thermal release is defined according to specific values of
applied overload current, as follows:
Text current

Tripping time

1.13In

>1h (In < 63A)


>2h (In > 63A)
<1h (In < 63A)
<2h (In > 63A)
1s<t<60s (In < 32A)
1s<t<120s(In > 32A)

1.45In
2.55In

MCB Add-on Functions


Various accessories can be added to MCBs to enable remote access and signalling.
For example, the contact status could be relayed to an alarm annunciator panel
or SCADA system; the circuit breaker could be controlled also from the
SCADA system.

Auxiliary Contacts
Relaying of contact status can be achieved by the addition of an auxiliary contact
and the contact form selected to suit the remote system input requirements.

Shunt Trip
The addition of a shunt trip allows remote access to the breaker operation,
permitting the supervisory system to manually trip the breaker. The shunt trip
actuator is a coil that is normally de-energised in the closed (on) state. When
activated, the shunt trip will force the breaker to its off state and the toggle
handle and indicator flag will move to this corresponding position. Since the
fail-safe (i.e. non-powered) state of a shunt coil is with the breaker remaining
closed, this precludes its use for emergency stop purposes. The interconnecting
wiring could be open-circuit, for example, and would therefore not allow the shunt
to open the breaker when the remote emergency switch is closed.

Under-voltage Release
If the supply voltage dropped to a low level and devices tripped, a dangerous
situation could exist if the devices were automatically reset. For example, motors
could suddenly restart or other operating machinery set in motion without warning.
In the event that the mains voltage should drop significantly below its normal
operating range, typically to less than 50%, an under-voltage release will force the
breaker to its off state and the toggle handle and indicator flag will move to this
corresponding position. Only when the supply has returned to, typically, at least
85% of normal operating voltage will the under-voltage release allow the breaker to
be closed.
If a break occurred in the interconnecting wiring in this case, the breaker would be
tripped, just as if the voltage had fallen below the threshold value. For this reason,
it is advisable to include an alarm function when using a UVR function.

141

Energy Let-through
An important facet of circuit protection devices is the extent to which they limit the
amount of electrical energy they allow to pass through them. This applies to fuses
as well as to circuit breakers.
When an electric current flows through a resistance for a certain time, energy
is produced in the form of heat. This thermal effect can be measured using
the formula:
I2 x R x t, to give a quantity in Watt seconds. The unit of measurement for energy
is the Joule, which is equivalent to one Watt second.
For all practical purposes, the resistance is treated as constant and negligible;
therefore the commonly accepted term for energy let-through of a device is I2t
since this will always be proportional to the true thermal effect. The I2t term is
referred to as the Joule Integral since the results are expressed in integral form.
Under short-circuit fault conditions there is the potential for considerable energy
to be let through by a circuit protection device. Knowledge of the energy letthrough characteristics of circuit protection devices is useful for comparison
between different devices and also with regard to the selection of devices that are
required to act in co-ordination to produce the levels of discrimination required for
fault clearance.
The I2t characteristics of circuit breakers are depicted as curves, graphed against
values of prospective short-circuit current. These characteristics are relevant to
both MCBs and MCCBs as depicted in the following graphs.

Energy Let-through Characteristics


10

10

5
4

B25

B20
B16

B10
B13
4

B6

10

2.5

10

9 10 4

I t/As

Ip/A

3
2

10

8
6

D32

D25
D20

4
3

D16
D10
D13
D6

10

8
6
5
4
3
2

10

10 3

1.5

2.5

Prospective current I p (A)

C6

10 3

1.5

2.5

Prospective current I p (A)

C10
C13

C16

Max. operating I t (A s)

C25
C20

1.5

C40
C32

10 3

C50

C63

Prospective current I p (A)

142

B40
B32

10

Max. operating I t (A s)

Max. operating I t (A s)

B63

B50

10

Ip/A

10

10

I t/As

Ip/A

10

I t/As

9 10 4

9 10 4

Within the EN 60898 standard, circuit breakers with B and C characteristics are
categorised into energy limiting classes 1, 2 and 3, with Class 3 denoting devices
having the lowest energy let-through. The appropriate energy class is marked
within a square box on conforming devices. Dorman Smith MCBs are categorised
within Class 3.
The following table indicates the maximum energy let-through values permissible in
each class, stated in Watt-seconds. In practice, compliance with the standard is
checked on the circuit breakers with the highest applicable rated current within the
range, normally 40A.

Rated
shortcircuit
capacity

Current
Class 1
rating (A) I2t max.

6kA

1-16
20-32
40
1-16
20-32
40

10kA

Class 2
I2t max.

B type and B type


C type

100,000
130,000
156,000
240,000
310,000
372,000

No
limits
specified

Class 3
I2t max.

C type

B type

C type

120,000
160,000
192,000
290,000
370,000
444,000

35,000
45,000
54,000
70,000
90,000
108,000

42,000
55,000
66,000
84,000
110,000
132,000

Effect of the ambient temperature on the tripping characteristic


70

T/ C
60

te

te

50

40

30

20

10

-10

-20

I(xC)

-30

k= ----------------I(30C)

-40
0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5

Correction factor is valid for current with times over 30 s


I(xC) - test current at x ambient temperature
I(30C) - test current at 30C ambient temperature
In
[A]
0,5
1
1,6
2
4
6
10
13
16
20
25
32
40
50
63

-40
0,61
1,22
1,95
2,44
4,88
7,32
12,2
15,9
19,5
24,4
30,5
39
48,8
61
76,9

-30
0,6
1,2
1,92
2,4
4,8
7,2
12
15,6
19,2
24
30
38,4
48
60
75,6

-20
0,59
1,18
1,89
2,36
4,72
7,09
11,8
15,4
18,9
23,6
2,5
37,8
47,8
59,1
74,4

-10
0,57
1,15
1,84
2,30
4,61
6,91
11,5
14,9
18,4
23
28,8
36,9
46,1
57,6
72,6

Ambient temperature T/OC


0
10
20
30
0,56 0,54 0,52
0,5
1,12 1,09 1,05
1
1,79 1,74 1,68
1,6
2,24 2,18
2,1
2
4,49 4,36 4,20
4
6,73 6,54 6,31
6
11,2 10,9 10,5
10
14,5 14,1 13,6
13
17,9 17,4 16,8
16
22,4 21,8
21
21
28
27,2 26,3
25
35,9 34,9 33,6
32
44,9 43,6
42
40
56,1 54,5 52,6
50
70,7 68,7 66,2
63

40
0,47
0,94
1,51
1,88
3,77
5,66
9,44
12,2
15,1
18,8
23,6
30,2
37,7
47,2
59,4

50
0,44
0,88
1,42
1,77
3,55
5,33
8,89
11,5
14,2
17,7
22,2
28,4
35,5
44,4
56

60
0,41
0,82
1,32
1,65
3,29
4,94
8,23
10,7
13,2
16,5
20,6
26,3
32,9
41,2
51,9

70
0,38
0,75
1,2
1,5
3
4,5
7,5
9,75
12
15
18,8
24
30
37,5
47,3

143

Maximum Zs for Loadlimiter MCBs

Current
rating (A)
6
10
13
16
20
25
32
40
50
63

B type
0.4s
5s

0.4s

5s

0.4s

5s

7.6
4.6
3.7
2.9
2.3
1.8
1.4
1.1
0.9
0.7

3.8
2.3
1.8
1.4
1.1
0.9
0.7
0.6
0.5
0.4

5.9
3.5
2.8
2.2
1.7
1.4
1.1
0.9
0.7
0.6

2.7
1.6
1.3
1.0
0.8
0.6
0.5
0.4
0.3
0.3

3.6
2.9
2.3
1.8
1.4
1.1
0.9
0.7
0.6
0.5

7.6
4.6
3.7
2.9
2.3
1.8
1.4
1.1
0.9
0.7

C type

D type

The above table is based on 230V rated voltage to earth.


Minimum Fuse Rating for Discrimination

Current
rating (A)
6
10
13
16
20
25
32
40
50
63

B type

20
20
20
32
40
50
63
80
100
125

C type
Fuse link rating (A)

32
32
32
50
63
80
100
100
125
125

D type

25
40
40
63
63
80
100
125
125
125

Maximum Back-up Fuse Rating for Protection

Current
rating (A)
6
10
13
16
20
25
32
40
50
63

144

B type

63
80
80
80
80
100
100
125
160
160

C type
Fuse link rating (A)

40
63
63
80
80
100
100
125
160
160

D type

40
63
63
80
80
100
100
125
160
160

Residual Current Circuit Breakers


Currents of low magnitude caused by unintentional leakage paths to earth can cause
deterioration within circuit wiring and components with the potential to create a
rapidly escalating situation that will permit the current to reach dangerous levels.
Special forms of circuit breakers are designed to use the detection of earth leakage
or residual current to limit the effects of this type of fault.
The generic term residual current device is used to describe a range of circuit
protection devices that include the functions of sensing and measurement of a
leakage current, with subsequent tripping when the magnitude of the residual
current reaches a preset level. The purpose of these devices is to protect human
life, livestock, property and equipment against the escalation of earth fault currents
to destructive magnitudes.
Two forms of technology are commonly employed in the design of residual current
devices; electromagnetic and electronic. In both cases, a current transformer is
used and is arranged such that normal current flows in the phase and neutral
conductors cancel each other to produce a zero balance. The presence of any
residual current will create an out-of-balance that can be used to signal the
actuation of a mechanism for circuit interruption.
In the electromagnetic type, a trip relay is used as the actuation device. The relay is
powered by the fault current and therefore requires no external power source.
With electronic devices internal signal amplification allows a much smaller current
transformer to be used, reducing the physical size of the circuit breaker. In this
case, however, the actuation power is derived from both the fault current and the
mains power. Also, a separate earth reference connection may be required to
ensure continuity of operation in the event that the mains neutral is lost.
Residual current devices are accorded a sensitivity coding that indicates the level
of residual current that would cause a trip action. Commonly, the available
sensitivity ranges are 10mA, 30mA, 100mA and 300mA. In general, the 10mA and
30mA devices are used to protect human life, the 100mA and 300mA devices
being applied to protect wiring, cabling and equipment.
The degree of electrocution that could take place when a fault arises depends upon
the combined effects of the magnitude and duration of current flow. For sensitivity
levels of 30mA and below, tripping must be instantaneous to protect human life.
Longer periods of residual current flow can be tolerated by equipment and the trip
action may not necessarily be required to interrupt the circuit instantaneously.

Residual Current Circuit Breaker


The RCCB device combines the functions of a switch with those of a residual
current device. It is often used in place of an incoming switch disconnector with
the advantage that it functions also as a residual current protection device. The
disadvantage, however, is that a residual fault will cause the device to operate
interrupting ALL downstream circuits even when these circuits remain in a
healthy state.
Note that an RCCB should not be used as the sole means to provide complete
protection. It has no overload or short circuit protection and must therefore be
further protected by an upstream device having these capabilities. Frequently, the
RCCB is used in consumer units and distribution boards to protect sub-circuits in a
split load configuration. In these applications, the upstream back-up is provided by
the Regional Electricity Companys local fuse.

Residual Current Breaker with Overload Protection


The RCBO combines the functions of an MCB with those of a residual current
device. It will therefore provide protection against overload, short circuit and
earth leakage.

145

RCBOs and RCCBs General


These devices are furnished with a test pushbutton on the front face of the
module. Operation of this button will simulate the presence of a residual fault and
the test should be made frequently, say once per month, to assure continued
correct functionality of the device.
In addition to the range of sensitivities, RCBOs and RCCBs are available in two
types, type AC and type A. These refer to the types of circuit for which the
devices are suitable.
Type AC: for use with residual sinusoidal ac, whether applied as a step or ramp.
Type A: for use with either residual sinusoidal ac or residual chopped (pulsating)
dc, whether applied as a step or ramp.
A time delay facility may also be included, adjustable up to, typically, 50-70mS.
This is denoted by S included within the description and also marked on the
device. This function is included in order to enable the device to be used as
part of a circuit device discrimination (or selectivity) arrangement. Without the
time delay, residual current circuit breakers cannot be easily used within a
discrimination scenario due to their inherent rapid tripping in response to residual
current detection.
Whereas RCBOs are single module width devices used in place of or alongside
MCBs in outgoing circuits, RCCBs are available in 2-pole and 4-pole forms and are
readily used in single phase and three phase distribution systems where they can
function as either incoming or outgoing ways.
Due to their low levels of sensitivity RCCBs are generally equipped with
suppression filtering to avoid nuisance tripping that could be induced from
disturbances in external or incoming circuits.

146

Modular Contactors
Contactors are simply electromechanically controlled switches. A contactor acts
as an interposing relay which, when its coil is energised, operates one or more
sets of contacts that are able to carry currents of sufficient magnitude to switch
power equipment such as large banks of lights, highly inductive lamps, motors and
large solenoids. The current required to operate the coil is minimal, therefore a
contactor can be controlled by light duty contacts in a timer, pushbutton or other
control device.
Generally, contactors have no latching facility, i.e. once the coil is de-energised the
contact state returns to its normal condition. However, whilst there is no
mechanical latching, electrical latching can be easily accomplished by using a
separate relay contact to hold on the supply to the contactors coil.

Selection Criteria
The correct choice of contactor depends upon a number of parameters within the
intended application. These include:
The form of power supply
The magnitude of the power to be switched
The type of load to be controlled
The control voltage required
The frequency of switching
Since the device operates by its coil being energised for possibly lengthy periods,
considerable internal heat can be generated. For this reason, a venting insert must
be placed between alternate pairs of contactors or between a contactor and any
other adjacent circuit device.

Switching Capacity
Contactor ratings are stated for AC1 type loads only (resistive). Where the load to be
switched differs from this, it is likely that the contactor will have to be de-rated to
ensure its performance. If the load is dc, inductive or capacitive, the degree of
de-rating may be considerable. The following contactor de-rating tables indicate the
maximum power/current that can be switched according to the type of load to be
controlled. The figures quoted are per phase and are based upon a 230V ac supply.

147

Modular Contactor Technical Data

GENERAL

Type
Standards
Module width
Mechanical
endurance
Ambient temp.
Storage temp.
No. of contactors
(side-by-side)
Contact reliability
Min. distance of
open contacts
Power dissipation
per pole
Overload current
withstand
capability
Max. back-up fuse
for short-circuit
protection gL
Coordination
type 2
Max. operating
frequency

Weight
Rated insulation
voltage
Rated impulse
withstand voltage
Thermal current
Rated operational
voltage
Rated frequency
Rated operational
current
Operational power
AC-1/AC-7a

op. c.

40 C
40 - 55 C

DC-1
AC-1/AC-3/
AC-5b/AC-6b
AC-15
no load

AC-1/AC-7a

3-pole
3-pole
AC-1/AC-7a
AC-3/AC-7b

230 V
400 V

1-phase
motor
AC-3/AC-7b
3-phase
motor
3-phase
motor
Electrical endurance AC-3/AC-7b
Switching of
AC-6b
capacitors
Electrical endurance AC-6b
Rated operational
DC-1
current
1-pole
U
U
U
2-poles connected
U
in series
U
U
3-poles connected U
in series
U
U
4-poles connected U
in series
U
U
Electrical endurance DC-1
Terminal capacity

230 V

148

max. 3
max. 2

Iv

230 V

EE4P63

max. 3
max. 2
17 V; 50 mA
3.6

1.7

1.7

72

68

176

240

20

25

63

80

op. c./h

300
600

Ui

kg
V

1,200
3,000
0.42
400

Uimp

kV

Ith
Ue

A
V

20
230

25

f
Ie

Hz
A

20

25

50/60
40

5.4

8.7

13.3

200,000
9

9
16

24
40

8.5

16
26
100,000
22

1.3 only for NO1) 1.32)

3.72)

52)

kW

2,2

5.5

8.5

11

15

op. c.
F

300,000
30

500,000
36

150,000
220

150,000
330

op. c.

200,000

Pe

kW

Ie

op. c.
A

Pe

400 V

230 V

EE4P40

-5 +55
-30 +80
no limitation

mm

230 V

Screw
Screw head
Tightening torque

EE4P25

IEC/EN 61095 , IEC/EN 60947-4-1, IEC/EN 60947-5-1


1
2
3
3 x 106

C
C

1-pole

Electrical endurance
Rated operational
current
Operational power

MAIN CIRCUIT

EE2P20

e = 24 V DC
e = 110 V DC
Ie
e = 220 V DC
e = 24 V DC

0.13
230

0.24
440

0.42

4
40
400

63

63

30

100,000

20
6
0.6
20

25
6
0.6
25

40
4
1.2
40

63
4
1.2
63

e = 110 V DC
Ie
e = 220 V DC
e = 24 V DC

10
6
-

10
6
25

10
8
40

10
8
63

e = 110 V DC
Ie
e = 220 V DC
e = 24 V DC

20
15
25

30
20
40

35
30

e = 110 V DC
Ie
e = 220 V DC

20
15
100000

40
40

63
63

rigid
flexible

op. c.
mm2

Nm

M3,5
PZ1
1.2

1.5 25
1.5 25
M5
PZ2
3.5

Modular Contactor Technical Data continued

CONTROL CIRCUIT

AUXILIARY CONTACTS

Type
Rated operational
voltage
Rated insulation
voltage
Rated impulse
withstand voltage
Thermal current
AC-15 Rated
1-phase
operational current 1-phase
Electrical endurance AC-15
Range of
control voltage
Control voltages
Surge immunity test
(1.2/50 s), acc. to
IEC/EN 61000-4-5
Coil consumption
Make/break delays
Terminal capacity

EE2P20

230 V
400 V

EE4P25

EE4P40

Ue

230

400

Ui

230

440

Uimp

kV

Ith
Ie

A
A

Uc

op. c.
%

Uc

switch-on
operation
make
break
rigid
flexible

4
20
6
300,000

25
6
4
500,000

V
kV

VA/W
ms

40
6
4
150,000
85 110

63

150,000

230
2

12/10
2.8/1.2
15 _ 25
10 _ 30

33/25
5.5/1.6
10 _ 30
10 _ 30

Screw
Screw head
Tightening torque

EE4P63

5/5
5/5
15 _ 20
35 _ 45
1 2.5
1 2.5

M3,5

5/5
5/5
15 _ 20
35 _ 45

M3
PZ1
0.6

Nm

Switching of Lamps
Max. number of lamps per pole at 230 V 50 Hz
Type

Power (W)

Current (A)

C (F)

EE2P20

EE4P25

EE4P40

EE4P63

Incandescent lamps
(tungsten filament)

60
100
200
500
1000
18
24
36
58
2 x 18
2 x 24
2 x 36
2 x 58
18
24
36
58
18
36
58
2 x 18
2 x 36
2 x 58
50
80
125
250
400
700
1000
50
80
125
250
400
700
1000

0.26
0.44
0.87
2.17
4.35
0.37
0.35
0.43
0.67
0.11
0.14
0.22
0.35
0.12
0.15
000
0.32
0.09
0.16
0.25
0.17
0.32
0.49
0.61
001
1.15
2.15
3.25
005
008
0.28
0.41
0.65
1.22
1.95
3.45
005

2.7
2.5
3.4
5.3

4.5
4.5
4.5
7

7
8
10
18
25
45
60

33
20
10
3
1
22
22
17
14
2 x 30
2 x 24
2 x 17
2 x 10
7
7
7
4
25
15
14
2 x 12
2x7
2x7
14
10
7
4
2
1
1
4
4
3
1
1
_
_

33
20
10
3
1
24
24
20
17
2 x 40
2 x 31
2 x 24
2 x 14
8
8
8
5
35
20
19
2 x 17
2 x 10
2x9
18
13
9
5
3
2
1
5
5
4
2
1
_
_

65
40
20
8
4
90
90
65
45
2 x 100
2 x 78
2 x 65
2 x 40
48
48
48
31
100
52
50
2 x 50
2 x 26
2 x 25
38
29
20
10
7
4
3
31
27
22
12
9
5
4

85
50
25
10
5
140
140
95
70
2 x 150
2 x 118
2 x 95
2 x 60
73
73
73
47
140
75
72
2 x 70
2 x 38
2 x 36
55
42
29
15
10
6
4
47
41
33
18
13
7
5

Incandescent lamps
uncompensated or series
compensated
Incandescent lamps
lead-lag circuit

Incandescent lamps
parallel compensated

Fluorescent lamps with


electronic ballast units (EVG)

High-pressure
mercury-vapour lamps.
Uncompensated

High-pressure
mercury-vapour lamps.
Parallel compensated

149

Modular Contactor Switching of Lamps continued


Type

Power (W)

Current (A)

C (F)

EE2P20

EE4P25

EE4P40

EE4P63

Halogen metal-vapour lamps.


Uncompensated

35
70
150
250
400
1000
2000
35
70
150
250
400
1000
2000
20
35
70
150
20
50
75
100
150
200
300
150
250
400
1000
150
250
400
1000
20
35
70
150
18
35
55
90
135
180
18
35
55
90
135
180

0.53
001
002
003
004
010
16.5
0.25
0.45
0.75
002
003
006
012
000
000
0.36
001
_
_
_
_
_
_
_
002
003
005
10.3
0.83
002
002
006
000
000
0.36
001
0.35
002
002
002
004
003
0.35
0.31
0.42
0.63
0.94
1.16

6
12
20
33
35
95
148
integrated
integrated
integrated
integrated
_
_
_
_
_
_
_
_
_
_
_
20
33
48
106
integrated
integrated
integrated
integrated
_
_
_
_
_
_
5
20
20
26
45
40
Lumilux T5

18
10
5
3
3
1

5
2
1
_
_
_
_
9
6
5
4
40
20
13
10
7
5
3
5
3
2
_
1
_
_
_
9
6
5
4
22
7
7
4
3
3
6
1
1
1
_
_

22
12
7
4
3
1

6
3
1
1
1
_
_
9
6
5
4
52
24
16
12
9
6
4
6
4
2
1
1
1
_
_
9
6
5
4
27
9
9
5
4
4
7
1
1
1
_
_

43
23
12
7
6
2
1
36
18
11
6
6
2
1
18
11
10
8
110
50
35
27
19
14
9
17
10
6
3
11
6
4
2
18
11
10
8
71
23
23
14
10
10
44
11
11
8
5
4

60
32
18
10
9
3
1
50
25
15
9
8
3
2
20
13
12
10
174
80
54
43
29
23
14
22
13
8
3
16
10
6
3
20
13
12
10
90
30
30
19
13
13
66
16
16
12
8
7

22
40
55
14
21
28
35
24
39
49
54
80
2 x 22
2 x 40
2 x 55
2 x 14
2 x 21
2 x 28
2 x 35
2 x 24
2 x 39
2 x 49
2 x 54
2 x 80

0,11
0,21
0,28
0,08
0,11
0,14
0,18
0,12
0,20
0,24
0,27
0,39
0,23
0,42
0,55
0,15
0,22
0,28
0,36
0,24
0,39
0,48
0,54
0,74

22
12
8
30
22
18
14
20
12
10
9
6
2 x 11
2x6
2x4
2 x 15
2 x 11
2x9
2x7
2 x 10
2x6
2x5
2x4
2x3

30
15
12
40
30
22
18
26
16
14
13
8
2 x 15
2x7
2x6
2 x 20
2 x 15
2 x 11
2x9
2 x 13
2x8
2x7
2x6
2x4

80
40
30
105
80
60
48
70
42
35
32
22
2 x 40
2 x 20
2 x 15
2 x 52
2 x 40
2 x 20
2 x 24
2 x 35
2 x 21
2 x 17
2 x 16
2 x 11

110
60
45
150
115
90
70
100
62
52
47
32
2 x 55
2 x 30
2 x 22
2 x 75
2 x 57
2 x 45
2 x 35
2 x 50
2 x 31
2 x 26
2 x 23
2 x 16

Halogen metal-vapour lamps,


parallel compensated

Halogen metal-vapour lamps,


with electronic ballast unit PCI
50-125 x In lamp for 0.6 ms
Transformers for halogen
metal-vapour lamps

High-pressure
sodium-vapour lamps.
Uncompensated
High-pressure
sodium-vapour lamps.
Parallel compensated
Halogen metal-vapour lamps
with electronic ballast unit PCI
50-125 x In lamp for 0.6 ms
Low-pressure sodium-vapour
lamps. Uncompensated

Low-pressure sodium-vapour
lamps. Compensated

LUMILUX* Fluorescent lamps


T5 with electronic ballast unit
(EVG)

FC

HE

HO

2 x FC

2 x HE

2 x HO

*LUMILUX is a trademark of OSRAM GmbH

150

Moulded Case Circuit Breakers


The operation and application of the MCCB is similar to that of the MCB, however
this device has the air-break mechanism contained within a moulded case housing
made from a very robust non-conducting material. Generally, MCCBs exhibit much
higher breaking capacities and rated current than their smaller counterparts and
can be used to perform full isolation duty. Consequently, MCCBs are employed in
both incoming and outgoing circuits. MCCBs are constructed to a particular frame
size and typically provide rated current in the range 16-1600A.
These devices can be equipped with adjustable thermal and magnetic tripping
mechanisms to cater for overload and short circuit protection to meet the
requirements for isolation and Category A discrimination duty. Dorman Smith
electronic MCCBs provide adjustable long, short and instantaneous trip functions,
allowing more complex overall tripping characteristics to be configured, allowing
these devices to be used for isolation and Category B discrimination requirements.
(Refer to page 136 for Category definitions).
Devices equipped with the full range of adjustable trips for long, short and
instantaneous durations are generally referred to as LSI-MCCBs to distinguish
them from the L and I only versions employed for Category A devices.
The range of accessories that can be added to MCCBs is similar to that given in the
section dealing with MCBs, including shunt trips, under-voltage releases and various
forms of auxiliary contacts. The physical size of triple-pole and four-pole MCCBs
allows these accessories to be internally mounted, although there are some
restrictions with regard to combinations of these that can be co-mounted. For
example, either a shunt trip or under-voltage release can be incorporated, but not
both. Also, due to the much larger physical size of these devices compared with
MCBs, additional safety features normally include interphase barriers and terminal
shrouds to provide IP2X ingress protection at the terminals.
The tripping operation of some MCCBs is different from that of MCBs in that there are
three distinct positions of the toggle or handle. Whereas MCBs are either on or off,
MCCBs have a central position when they are tripped. As a further safety feature, the
coloured flags indicating the on and off states are masked in the tripped state. The
breaker can be reset only after it has been set into the fully off state.
MCCBs are equipped with a test pushbutton that allows periodic testing of the
mechanical tripping mechanism. As in the case of a fault trip, the device must be
moved into the off position before it can be reset following a test.
These devices conform to EN 60947-2 therefore the definitions that apply to some
parameters differ from those of EN 60898 that apply to miniature circuit breakers.
These differences are explained in the section covering Standard Terminology.

Motor Control Applications


The MCCB is a viable means of providing motor control switching. However,
MCCBs used for this type of application are often required to provide only short
circuit protection, with the overload protection catered for by a separate thermal
or electronic overload relay. For this reason, specifically designed motor control
MCCBs are available upon request, with only the single tripping mechanism.
The range of circuit breakers for each frame size includes a basic switch
disconnector version, generally in both triple-pole and four-pole variants. Devices of
this type are sometimes referred to as non-auto MCCBs.

151

Loadline YA Frame MCCBs for Motor Starting (415 V ac)

Motor
rating

Motor full
load
current

Sub-transient
starting
current

P(Kw)

Ie(A)

Id"(A)

0.37
0.55
0.75
1.10
1.50
2.20
3.00
4.00
5.50
7.50
9.00
11.00
15.00
18.50
22.00
30.00
37.00
45.00
55.00
75.00
90.00
110.00
132.00
150.00

1.2
1.6
2
2.8
3.7
5.3
7
9
12
16
20
23
30
37
43
59
72
85
105
140
170
210
224
255

14
19
24
34
44
64
84
108
144
192
240
276
360
444
516
708
864
1020
1260
1680
2040
2520
2688
3060

Notes
1
2

Breaker
frame

YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA2/YA3
YA3
YA3
YA3
YA5
YA5
YA5

Breaker
rated
current

Breaker
instantaneous
trip threshold
(set on max.)

In(A)

Ii (lower
tolerance) (A)
192
192
192
192
192
192
192
192
192
307
307
480
480
480
605
960
1200
1200
1664
2600
2600
3840
3840
3840

20
20
20
20
20
20
20
20
20
32
32
50
50
50
63
100
125
125
160
250
250
400
400
400

In>le
li/lower > ld"

The above table is suitable for DOL and Star Delta starting.

152

Discrimination
In the context of power distribution schemes, the term discrimination (sometimes
referred to as selectivity) describes a hierarchy of circuit devices that are arranged
such that a single upstream circuit breaker can fan out to several downstream
devices to act in a co-ordinated fashion should a fault occur. Under fault conditions,
only the upstream protective device closest to the fault should operate to clear the
fault, leaving all other healthy circuits operable. This is especially important in
installations where circuit failures could be life-threatening, such as in hospitals.
The concept of discrimination is similar to that of cascading, the prime difference
being in the objectives of the application. Whereas discrimination is used to ensure
continuity of supply to sub-circuits by limiting the disconnection to the faulted
sub-circuit alone, cascading is used to buffer downstream protective devices
against the effects of high prospective short circuit currents.
In both cases, the protective devices are specifically selected to meet the criteria
for the type of co-ordination required.
When the selected devices are properly matched to fulfil the ideal discrimination
principle described above, the co-ordinating devices are said to achieve total
discrimination. In many practical installations, however, a partial discrimination may
be satisfactory for safe continuity of supply, with an added advantage of cost
savings due to selecting a lower rated upstream circuit breaker.
Discrimination between two circuit breakers arranged in series may be based on
either current or time. Where the magnitude of the fault current is to be used as
the critical factor for selection, the co-ordination in this case is termed current
discrimination. Where the basis for selection is the duration over which the
upstream device can withstand the fault current, the selection is to achieve time
discrimination. In some cases, time discrimination can be achieved by using an
upstream device that has a built-in time delay.
Current Discrimination
In general, the basis for current discrimination is that the downstream protective
device will have a lower current rating than the upstream device. It should also
have a lower instantaneous tripping point. The discrimination tables that follow
highlight the consequential increase in discrimination level as the differential in
current ratings between the devices increases.
Time Discrimination
Discriminating by time between two devices in series relies on the operation of the
upstream device being delayed at least until the downstream circuit breaker has
tripped to clear the fault. The clearing time of the downstream device must be less
than the time setting of the upstream device and the upstream device must also be
capable of withstanding the fault current for the full duration of its time setting.
There is generally no problem in achieving these conditions where the upstream
device is a Category B circuit breaker specifically designed for this type of
co-ordination duty.
Time/Current Characteristics
Comparison of the time/current characteristic graphs of the two devices proposed
can give a quick check on their suitability for co-ordination in both current and time
discrimination cases. Ideally, there should be no overlap of the respective curves to
achieve total discrimination. If, however, the instantaneous portion of the curves do
intersect, a partial discrimination will be achieved at the current level projected
from the intersect point.
In the tables that follow, total discrimination is indicated by the letter T in
appropriate boxes. Total discrimination applies for all fault levels up to the lower
breaking capacity of the two devices in co-ordination. Where a value is contained
in any of the boxes, this indicates a partial discrimination of that value of current
limit. If no discrimination is possible, this is shown by a dash symbol.

153

Note that partial discrimination infers that, above the current limit value indicated, it is possible that both devices could trip,
resulting in disconnection of other sub-circuits and loss of supply continuity to those areas of the distribution system.

Discrimination Tables

UPSTREAM ELECTRONIC ACB


Z2 1250A

Z2 800A

Z2 1600A

Z2 2000A

Z3 2500A

Z3 3200A

Z3 4000A

Frame
Rating
Model

125A

DOWNSTREAM MCCB

250A

400A

800A

1250A
1600A

YA2N
Thermal/
Mag
YA2S
Thermal/
Mag
YA2J
Thermal/
Mag
YA3N
Thermal/
Mag
YA3S
Thermal/
Mag
YA3J
Thermal/
Mag
YA5N
Thermal/
Mag
YA5H
Thermal/
Mag
YA5H
Electronic
YA5J
Thermal/
Mag
YA5K
Electronic
Y6H
Thermal/
Mag
Y6H
Electronic
Y6J
Electronic
Y6K
Thermal/
Mag
Y7J
Electronic
Y8K
Electronic

STD
HIGH
STD
HIGH
STD
HIGH
STD
HIGH
STD
HIGH
STD
HIGH
STD
Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity Capacity
Breaking 65kA
Capacity

80kA

65kA

80kA

65kA

80kA

65kA

80kA

85kA

100kA

85kA

100kA

100kA

25kA

36kA

65kA

25kA

36kA

65kA

25kA

50kA

50kA

65kA

70kA

50kA

50kA

65kA

85kA

65kA

85kA

T= Total Selectivity
Notes: All ACBs have instantaneous trip set to NON and the MCR set to ON.
Assumes all ACB time settings are greater than MCCB.
The above table is in accordance with IEC 60947-2, Annex A.

154

Discrimination Tables

UPSTREAM ELECTRONIC MCCB


Frame
Rating

400A

DOWNSTREAM MCCB

Model

YA5HElectronic

YA2N
Thermal/
Mag
YA2S
125A Thermal/
Mag
YA2J
Thermal/
Mag
YA3N
Thermal/
Mag
YA3S
250A Thermal/
Mag
YA3J
Thermal/
Mag
YA5N
Thermal/
Mag
YA5H
Thermal/
Mag
400A YA5H
Electronic
YA5J
Thermal/
Mag
YA5K
Electronic

800A

1250A

1600A

YA5KElectronic

Y6HElectronic

Y6JElectronic

Y7JElectronic

Y8KElectronic

Breaking 50kA
Capacity

70kA

50kA

65kA

65kA

85kA

25kA

36kA

65kA

50

25kA

36kA

65kA

50

50

25kA

50kA

25

25

50kA

25

25

65kA

25

25

70kA

25

25

T= Total Selectivity
Notes: All pick-up current and time delay settings to be set at maximum on
upstream MCCBs.
Partial discrimination level is in kA.
The above table is in accordance with IEC 60947-2, Annex A.

UPSTREAM THERMAL MAGNETIC MCCB

DOWNSTREAM K SERIES MCB

YA2N (25kA) or YA2S (36kA)

YA3N (25kA) or YA3S (36kA)

YA5H
(50kA)

In

20A 32A 50A 63A 100A 125A 20A 32A 50A 63A 100A 125A 160A 200A 250A 250A 400A

6A

260 T

260 T

10A

260 420 T

260 420 T

16A

260 420 650

260 420 650 T

20A

260 420 650

1000 T

260 420 650 1000 T

25A

260 420 650

1000 T

260 420 650 1000 T

32A

260 420 650

1000 1500 T

260 420 650 1000 1500 T

40A

260 420 650

1000 1500 2000 260 420 650 1000 1500 2000 T

50A

260 420 650

1000 1500 2000 260 420 650 1000 1500 2000 3000 T

63A

260 420 650

1000 1500 2000 260 420 650 1000 1500 2000 3000 2600 T

T= Total Selectivity
Notes: MCBs can be of any manufacture as long as they are Energy Class 3 as
defined in EN 60898.
Table based on Type B & C characteristic MCBs.
MCBs can be 6kA or 10kA at 400V ac.
Partial discrimination level is in amps.
The above table is in accordance with IEC 60947-2, Annex A.

155

Discrimination Table

UPSTREAM THERMAL MAGNETIC MCCB

DOWNSTREAM
K SERIES D TYPE MCB

YA2N (25kA) or YA2S (36kA)


20A

32A

50A

63A

80A

YA3N (25kA) or YA3S (36kA)

100A 125A 16A

20A

32A

50A

63A

80A

16A

100A 125A 160A 200A 250A 250A 400A

6A

166

192

307

480

605

832

960

1200

166

192

307

480

605

832

960

1200

1664

2080 2000 2400 3840

10A

307

480

605

832

960

1200

307

480

605

832

960

1200

1664

2080 2000 2400 3840

16A

480

605

832

960

1200

480

605

832

960

1200

1664

2080 2000 2400 3840

20A

480

605

832

960

1200

480

605

832

960

1200

1664

2080 2000 2400 3840

25A

605

832

960

1200

605

832

960

1200

1664

2080 2000 2400 3840

32A

832

960

1200

832

960

1200

1664

2080 2000 2400 3840

40A

960

1200

960

1200

1664

2080 2000 2400 3840

50A

1200

1200

1664

2080 2000 2400 3840

63A

1664

2080 2000 2400 3840

T= Total Selectivity
Notes: Table based on Type D characteristic MCBs.
MCBs can be 6kA or 10kA at 400V ac.
Partial discrimination level is in amps.

156

YA5H (50kA)

In

Cascading
Cascading is sometimes referred to as back-up protection. The technique of
cascading is used to allow circuit breakers with a breaking capacity lower than the
value of prospective short-circuit current at the connection point to be used when
these are positioned downstream of a current-limiting circuit breaker of higher
breaking capacity. The net result of this arrangement is that the downstream
device acquires an enhanced installed breaking capacity, therefore a less
expensive, lower breaking capacity breaker can be used.
The upstream circuit breaker must have the normally required breaking capacity
for its point of installation however, when combined with another circuit breaker
downstream, the two devices in series will be able to clear a larger fault. For
example: if a 10A, 6kA MCB is place downstream of a YA frame MCCB rated at
125A and 25kA, the MCB will have an installed breaking capacity of 14kA. Similarly,
a 10A, 10kA MCB downstream of a YA frame MCCB rated at 250A and 25kA will
have an installed breaking capacity of 25kA.
It should be noted that the cascading technique is not limited to only two devices
in series. The important point is that it is the upstream device that is limiting the
current to a value that can be interrupted by the following device, so that the
pattern of paired devices can be repeated many times in an hierarchy of devices.
The following tables give installed breaking capacity values of downstream circuit
breakers for both the MCCB/MCB and MCCB/MCCB pairings of cascaded devices.
Note that all values shown are at 400V ac. The values for the installed breaking
capacities are given in kA.
Upstream YA frame MCCB with downstream S-series MCB

MCB
(6kA)

MCCB
YA2N
(25kA)
125A

MCCB MCCB MCCB MCCB MCCB MCCB MCCB


YA2S
YA2J
YA3S
YA3J
YA3N
YA3S
YA3J
(36kA) (65kA) (36kA) (65kA) (25kA) (36kA) (65kA)
125A
125A
160A
160A
250A
250A
250A

14

14

14

12

12

12

12

12

10

14

14

14

12

12

12

12

12

16

14

14

14

12

12

12

12

12

20

14

14

14

12

12

12

12

12

32

14

14

14

12

12

12

12

12

40

12

12

12

10

10

10

10

10

50

12

12

12

10

10

10

10

10

63

12

12

12

10

10

10

10

10

Upstream YA frame MCCB with downstream K-series MCB


UPSTREAM MCCB
125A

Frame
Rating

DOWNSTREAM MCB

Model

YA2N T/Mag

250A

YA2S T/Mag YA2J T/Mag

YA3N T/Mag YA3S T/Mag

YA3J T/Mag

Current Breaking 25kA


Rating Capacity

36kA

65kA

25kA

36kA

65kA

6A

10kA

25

30

30

25

25

25

10A

10kA

25

30

30

25

25

25

16A

10kA

25

30

30

25

25

25

20A

10kA

25

30

30

25

25

25

25A

10kA

25

30

30

25

25

25

32A

10kA

25

30

30

25

25

25

40A

10kA

25

30

30

23

23

23

50A

10kA

25

30

30

23

23

23

63A

10kA

25

30

30

23

23

23

157

Cascading (continued)
UPSTREAM MCCB
Frame
Rating

125A

DOWNSTREAM MCCB

Model

YA2N
T/Mag
125A YA2S
T/Mag
YA2J
T/Mag
YA3N
T/Mag
YA3S
250A
T/Mag
YA3J
T/Mag

YA2N
T/Mag

250A

YA2S
T/Mag

YA2J
T/Mag

YA3N
T/Mag

YA3S
T/Mag

YA3J
T/Mag

Breaking 25kA
Capacity

36kA

65kA

25kA

36kA

65kA

25kA

36

50

36

50

36kA

65

65

65kA

25kA

36

50

36kA

65

65kA

UPSTREAM MCCB
Frame
Rating

125A

DOWNSTREAM MCCB

Model

YA2N
T/Mag
125A YA2S
T/Mag
YA2J
T/Mag
YA3N
T/Mag
YA3S
T/Mag
YA3J
T/Mag
YA5N
T/Mag
YA5H
T/Mag
YA5J
T/Mag

YA5H
T/Mag

YA5H- YA5J
Electric T/Mag

250A
YA5K- Y6HY6J
Electric Electric T/Mag

Breaking 50kA
Capacity

70kA

50kA

65kA

65kA

65kA

85kA

25kA

36

50

36

36

36kA

50

65

50

50

65kA

70

25kA

36

50

36

50

50

36kA

50

65

50

65

65

65kA

70

25kA

36

50

36

50

50

36

36

50kA

70

65

65

65

70kA

85

Notes: Cascade fault level is expressed in kA.

158

Y6JY7JY8KElectric Electric Electric

Short-circuit Discrimination Levels


Where a high prospective fault level exists at the MCB distribution point,
discrimination at short-circuit levels should be considered. This will require
comparison of the device I2t characteristics at the relevant prospective fault level.
Discrimination will be obtained at all fault levels for which the MCB total operating
I2t is lower than the pre-arcing I2t of the device closer to the supply.
The data for typical cartridge fuses can be extracted from graphs and is presented
in the following tables.

MCB, type B
Current
rating (A)

20

25

80

100

125

160

0.5

0.8

1.7

3.1

10

0.4

0.7

1.4

2.3

7.0

10.0

10.0

10.0

10.0

3.4

4.8

7.5

10.0

10.0

0.7

1.4
1.3

2.3

3.4

4.8

7.5

10.0

10.0

2.0

2.9

4.2

6.0

9.5

10.0

20

1.9

2.7

3.8

5.6

8.5

10.0

25

1.8

2.6

3.6

5.4

8.0

10.0

2.4

3.2

4.2

6.8

10.0

3.2

4.2

6.8

9.5

50

3.8

5.7

8.5

63

3.8

5.7

8.5

13
16

35

Fuse
sizes
50
63

32
40

MCB, type C
Current
rating (A)

1.7

3.1

7.0

10.0

10.0

10.0

10.0

1.4

2.3

3.4

4.8

7.5

10.0

10.0

13

2.3

3.4

4.8

7.5

10.0

10.0

16

2.0

2.9

4.2

6.0

9.5

10.0

2.7

3.8

5.6

8.5

10.0

3.6

0.5

0.8

10

20

5.4

8.0

10.0

32

4.2

6.8

10.0

40

4.2

25

6.8

9.5

50

5.7

8.5

63

5.7

8.5

MCB, type D
Current
rating (A)

3.0

5.9

6.0

6.0

6.0

6.0

6.0

1.3

2.2

3.6

6.0

6.0

6.0

6.0

13

1.7

2.5

4.0

6.0

6.0

6.0

16

1.6

2.2

3.1

4.6

6.0

6.0

2.2

3.1

4.6

6.0

6.0

25

3.1

4.6

6.0

6.0

32

2.6

3.5

6.0

6.0

3.5

6.0

6.0

5.5

6.0

6
10

20

40
50

0.7

1.7

63

159

System Sizing and Diversity


The adequacy of sizing and rating of power distribution systems is important to
ensure supply continuity and safety in operation. A number of design parameters
must be taken into account in order to ensure that the supply and safety
requirements are met. These include busbar ratings, short-circuit fault levels and
circuit utilisation.
Once the overall loading requirements have been established, and the supply
transformer selected, consideration of the circuit distribution systems follows.
Distribution enclosures and their busbar systems are pre-tested to accepted norms
of through-fault levels, typically 16kA, 25kA, 35kA, 50kA and 80kA. These shortcircuit ratings alone will limit the choice of switchboard, panel board or distribution
board. The selection of the type and size of enclosure to be used will then depend
upon the busbar current rating needed, together with availability of sufficient
circuit ways of the correct type for the circuits and sub-circuits to be supplied.
The busbar current rating is generally chosen to be sufficient to supply full load,
plus some safety factor. For example, if the full load is expected to be 750 amps,
an enclosure with a busbar rating of 800 amps may be selected. Once the busbar
current rating has been nominated, the incoming device for that group of circuits
will be matched to the rating. In the example cited, the incoming device would
be rated at 800 amps. More than one incoming device may be required to effect
proper circuit protection and isolation, such as a switch disconnector in series
with a thermal fuse. In this case, the fuse link will provide the protection and
the disconnector will permit isolation. Alternatively, a moulded case circuit
breaker (MCCB) employed as the incoming device will provide both protection
and isolation.
The size and type of circuits to be supplied will further refine the eventual choice
of distribution system. Automatic or manual circuit disconnection will point to
an enclosure suitable for either circuit breakers or switch-fuse devices. If the
requirement is for automatic disconnection, prospective fault levels at the
connection point may dictate that an MCCB must be used, rather than an MCB of
the same current rating.
Finally, consideration is given to the degree of circuit utilisation capacity, often
referred to as diversity. Notwithstanding the limitations of the busbar system and
the matched protection provided by the incoming device, the outgoing circuit ways
may be configured with individual circuit protection devices having an aggregate
rated current capacity in excess of the rating of the incomer.
The basis for this approach is that it is often reasonable to assume that not all
circuits will be supplying their rated current at the same time. In this case, a
diversity factor is applied during the design stage to give an overall service
capacity for the outgoing circuits. The maximum current rating divided by the
diversity factor will give the maximum aggregate fitted current allowed. The
following table lists the factors that may be applied subject to the number of
outgoing circuits to be supplied.
Taking the example of a 400A panel board with 400A MCCB incomer and 6
outgoing circuits, a diversity factor of 0.7 would allow outgoing MCCBs with an
aggregate of 570A capacity to be installed. The individual circuits would be
protected at the level of current rating of each MCCB, with the incomer providing
ultimate protection at 400A. To allow for the possibility of future expansion of a
distribution system, an allowance for 25% spare capacity is often included when
applying a diversity factor to the initial design.

160

Number
of circuits

MCCB panel boards


to EN 61439-2

MCB distribution boards


to EN 60439-3

2-3
4-5
6-9
10+

0.9
0.8
0.7
0.6

0.8
0.7
0.6
0.5

Prospective Short-circuit Current


The Prospective Short-circuit Current, or PSC, is the theoretical maximum fault
current that could exist at any point within a complete circuit distribution system.
The magnitude of the fault current at any particular point is calculated on the basis of
a bolted (virtually permanent) fault path at that point and therefore assumes a
constant voltage, continuous current supply feeding the fault. Using this assumption,
the PSC that could possibly exist at the bolted fault path would be limited only by the
sum of the circuit impedances of the complete current path, from high voltage feed
to the supply transformer through to the bolted connection point. Since this
assumption cannot be fulfilled in practice (for example, the voltage will not remain
constant) the value of calculated PSC can never be exceeded in a practical scheme.
The foregoing commentary is particularly relevant to larger commercial and industrial
networks, where many sub-systems are present and often, many sub-circuits within
these. For more compact arrangements, such as domestic installations, where the
distribution scheme is contained within one or more consumer units, the situation is
much simpler. The Regional Electricity Companies generally agree on a fixed fault
level of 16kA at the local zone supply distribution point to one or more dwellings.
Those dwellings that lie some distance from the zone origin point of the distributed
supply will have reduced PSC due to the higher impedance of the longer run of
service cable. Consumer units should therefore have a minimum short-circuit rating of
16kA. When an MCB trips, the combination of forced contact separation and rapid arc
extinction produces a limiting effect on the fault current such that it will be
adequately handled within the normal 6kA breaking capacity of MCBs fitted to
domestic installations.
PSC at the origin point
In practice and with consideration of the total distribution network; the breaking
capacity of an individual circuit device would normally be less than that calculated for
the origin point of the scheme.
PSC at the connection point
The breaking capacity of individual devices must be greater than (or at least equal to)
the PSC at the specific point of their connection within a scheme. Conversely, where
the circuit device breaking capacity is greater than the PSC at origin, there is no need
for further measurement or calculation in this regard.
The PSC at any particular connection point can be estimated, calculated, or
determined by measurement of the circuit impedance at that point. Measurement of
the circuit impedances at all relevant connection points can be a laborious exercise;
the calculation method is generally used since this can be readily carried out using
one of a number of available computer software packages.
PSC by calculation
The magnitude of the short-circuit current (rms value of the ac component) at the
connection point will depend upon:
the PSC at the origin point.
the total resistance in the circuit between the origin point and the relevant circuit
reference point.
whether the short-circuit condition is considered as phase-phase, phase-neutral or
phase-earth.
The maximum PSC at the origin can be calculated from the following formula:
PSC (kA) =

Supply transformer rating (kVA) x 100


3 x secondary voltage x % transformer reactance

PSC by estimation
To estimate the PSC, first calculate the total resistance in the LV circuit by
determining the sizes and lengths of cables between the supply source and the point
under consideration. Next, use the following table to find the cable resistances and
summate these to obtain the total resistance. Finally, use this value to read off the
estimated PSC from the following graph.

161

Maximum Resistance of Copper Conductors at 20C (milli ohms)

Nominal
cross
sectional
area (mm2)

10

15

90.50
60.50
37.10
23.10
15.40
9.15
5.75
3.64
2.62
1.94
1.34
0.96
0.77
0.62
0.49
0.38
0.30
0.23
0.18
0.14

181.00
121.00
74.10
46.10
30.80
18.30
11.50
7.27
5.24
3.87
2.68
1.93
1.53
1.24
1.00
0.75
0.60
0.47
0.37
0.28

182.00
111.00
69.20
46.20
27.50
17.30
10.90
7.86
5.81
4.02
2.88
2.30
1.86
1.49
1.13
0.90
0.70
0.55
0.42

20

30

148.00
92.20 138.00
61.60 92.40
36.60 54.90
23.00 34.50
14.50 21.80
10.48 15.70
7.74 11.60
5.36 8.04
3.86 5.79
3.06 4.59
2.48 3.72
1.98 2.97
1.51
2.26
1.20 1.80
0.94 1.41
0.73
1.10
0.57 0.85

40

50

60

70

80

90

100

123.00
73.20
46.00
29.10
21.00
15.50
10.70
7.72
6.12
4.96
3.96
3.02
2.40
1.88
1.46
1.13

91.50
57.20
36.40
26.20
19.40
13.40
9.65
7.65
6.20
4.96
3.77
3.00
2.35
1.83
1.42

110.00
69.00
43.60
31.40
23.20
16.10
11.60
9.18
7.44
5.96
4.52
3.60
2.85
2.20
1.78

80.50
50.90
36.70
27.10
18.80
13.50
10.70
8.68
6.94
5.28
4.20
3.29
2.56
2.15

92.00
58.20
41.90
31.00
21.40
15.40
12.20
9.92
7.93
6.03
4.80
3.76
2.93
2.51

65.40
47.20
34.80
24.10
17.40
13.80
11.20
8.92
6.79
5.40
4.23
3.29
2.88

72.70
52.40
38.70
26.80
19.30
15.30
12.40
9.91
7.54
6.00
4.70
3.66
3.25

Fault Current (kA)

1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

Cable length (m)

Total Circuit Resistance (m)

162

PSC in a typical installation

Note that the values on the graph assume a symmetrical fault across the three
phases. In a single circuit, for line-neutral faults, the cable resistance value given in
the table should be doubled.
The following values of PSC would be obtained at the various circuit points marked
in the above diagram:

Point A
Point B

Point C

Point D

PSC = approximately 27kA


Two cables per phase, therefore halve the value.
Resistance from A to B
= 0.3 Milli ohms
With reference to the graph PSC
can be assumed to be 25kA
Resistance from A to B
= 0.3 Milli ohms
Resistance from B to C
= 10.7 Milli ohms
Total circuit resistance A to C
= 11.0 Milli ohms
With reference to the graph PSC
can be assumed to be 12kA
Resistance from A to B
= 0.3 Milli ohms
Resistance from B to C
= 10.7 Milli ohms
Resistance from C to D
= 46.0 Milli ohms
(Double the value for the 2-core cable)
Total circuit resistance A to D
= 57.0 Milli ohms
With reference to the graph PSC
can be assumed to be 3kA

163

Earth Fault Protection


One of the most common means of protecting persons against the effects of high
voltages and currents is by insulating the wiring and components. Most earth faults occur
when some part of the insulation has broken down, creating the possibility of causing
electric shock through indirect contact with the faulty circuit. The breakdown of insulation
can often cause all or part of an enclosure or frame to become live by raising conductive
parts to a hazardous voltage level. Touching any of the exposed parts of the enclosure or
frame would then be highly dangerous and would most likely cause an electric shock.
Whilst protective devices may open quickly to minimise the possibility of high currents
flowing for any significant length of time, additional measures are necessary to limit the
potential earth fault current at source. In some cases fault current limiting resistors or
inductors may be installed at the transformer star point however, in all cases, it is
important to ensure that the impedance of circuit conductors is kept to a minimum so
that the voltage developed under fault conditions will be restricted. The earth fault loop
impedance is denoted Zs and is an important circuit design parameter.
Circuit designs must always ensure that the magnitude of the fault current will be
sufficient to trip the over-current protective devices within acceptable times as stated in
the IEE Wiring Regulations. Circuit breakers are designed to trip and therefore disconnect
faulted circuits very quickly. The design value of tripping time is generally expressed in the
form of a graph that maps current against time and any practical scheme can be checked
against this value to ascertain conformance with the requirements.
The fault current can be established very simply using Ohms law, as follows:
Fault current = Phase-to-earth voltage
Zs
Once this value is known, the corresponding tripping time can be read from the relevant
devices time/current characteristic graph and the result compared with that given within
the Wiring Regulations. In general, the higher the nominal voltage of an installation, the
shorter will be the required disconnection time. For fixed equipment installations, the
maximum disconnection time is stated as 5 seconds, whereas it is 0.4 seconds for
portable equipment. The Regulations define portable as including fixed outlet sockets
that may be used to supply apparatus that is movable or portable when in use.
The following table illustrates the maximum Zs allowable for MCBs to achieve the
specified disconnection times.

Current
rating (A)

10

16

20

25

32

40

50

63

Type B
max. Zs
(ohms)

8.00

4.80

3.00

2.40

1.92

1.50

1.20

0.96

0.76

Type C
max. Zs
(ohms)

4.00

2.40

1.50

1.20

0.96

0.75

0.60

0.48

0.38

Type D
max. Zs
(ohms)

2.00

1.20

0.75

0.60

0.48

0.38

0.30

0.24

0.19

Since the complete loop impedance is the sum of the individual impedances of the
supply transformer winding, circuit phase conductor and protective circuit
conductor, the total may be higher than that specified for in-time disconnection for
the protection device proposed. In these cases, several solutions may be possible
to overcome or at least assist in achieving compliance.
The supply cable may be replaced by one with greater cross sectional area
The short-circuit tripping threshold of the device may be set to a lower value
(if it is adjustable)
A Residual Current Device could be used to replace the circuit breaker in question
The following tables indicate the maximum Zs for Dorman Smiths range of
MCCBs. Using these tables obviates the need to determine the suitability of a
device by reference to its time/current characteristic graph.

164

Zs Values for YA2, YA3 and YA5 MCCBs

Maximum Allowable Earth Loop Impedance Values, in accordance with BS7671

MCCB Reference

S/C Protection
Setting

YA2 1P Fixed Mags

YA2N, 25kA

YA2 3P & 4P
Thermal Magnetic

YA2N, 25kA
YA2S, 36kA
YA2J, 65kA

MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX

YA3 1P Fixed Mags

YA3N, 25kA

YA3 3P & 4P
Thermal Magnetic

YA3N, 25kA
YA3S, 36kA
YA3J, 65kA

MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
MAX

Zs values @ 230 Volts


In
0.4 sec
5 sec
16
20
25
32
40
50
63
80
100
125

0.92
0.74
0.59
0.46
0.37
0.29
0.23
0.18
0.15
0.12

1.31
1.00
0.82
0.62
0.51
0.42
0.33
0.26
0.20
0.16

20
20
32
32
50
50
63
63
100
100
125
125

1.60
0.80
1.00
0.50
0.64
0.32
0.51
0.25
0.32
0.16
0.26
0.13

1.64
1.64
1.00
1.05
0.64
0.37
0.51
0.29
0.32
0.19
0.26
0.15

16
20
25
32
40
50
63
80
100
125
160

1.20
0.96
0.77
0.60
0.48
0.38
0.30
0.24
0.19
0.15
0.12

1.28
1.05
0.82
0.62
0.50
0.41
0.33
0.26
0.21
0.17
0.13

20
20
32
32
50
50
63
63
100
100
125
125
160
160
200
200
250
250

1.60
0.80
1.00
0.50
0.64
0.32
0.51
0.25
0.32
0.16
0.26
0.13
0.20
0.09
0.16
0.07
0.13
0.06

1.60
0.88
1.00
0.58
0.64
0.37
0.51
0.29
0.32
0.18
0.26
0.14
0.20
0.11
0.16
0.09
0.13
0.06

165

Zs values for Y6, Y7 and Y8 MCCBs


Maximum Allowable Earth Loop Impedance Values, in accordance with BS7671
Loadline MCCBs

Y6 Frame
Y6HJK
Thermal magnetic
Y6HJK
Thermal magnetic
Y6HJK
Thermal magnetic
Y6HJK
Electronic

Y6HKJ
Electronic

Y7 Frame
Y7JK
Electronic

Y7JK
Electronic

Y8 Frame
Y8JK
Electronic

166

Magnetic
adjustment

Set at maximum
Set at minimum
Set at maximum
Set at minimum
Set at maximum
Set at minimum
Set at maximum
"INST/STD"
Set at minimum
Set at maximum
"INST/STD"
Set at minimum

Set at minimum
"INST/STD"
Set at minimum
Set at minimum
"INST/STD"
Set at maximum

Set at minimum
"INST/STD"
Set at maximum

Breaking
capacity
(kA)

0.4 sec

5 sec

400
400
630
630
800
800
630

50
50
50
50
50
50
50

0.05
0.10
0.03
0.07
0.03
0.05
0.03

0.05
0.10
0.03
0.07
0.03
0.05
0.03

630
800

50
50

0.17
0.13

0.17
0.13

800

50

0.03

0.03

1000

65

0.02

0.02

1000
1250

65
65

0.10
0.08

0.1
0.08

1250

65

0.02

0.02

1600

85

0.07

0.07

1600

85

0.01

0.01

In

Max Zs values

Forms of Separation
The principle of separation applied to multi-cubicle switchboards and panel boards
is the achievement of a high degree of safety for equipment and people during
normal operation and to promote safe working during commissioning and service.
The resulting concept is one of functional separation and segregation of live parts
of the system into sub-units by the use of barriers or partitions.
In general, separation should provide enhanced safety by:
Protecting against contact with the live parts of adjacent functional units
Preventing the passage of solid foreign bodies from one section of an assembly
to an adjacent one
Various elements of an assembly must be considered for separation from
neighbouring live sections, such as busbars, terminals and functional units. The
specific form of their separation can be achieved in several ways according to the
particular application and the requirements for access for maintenance. The
minimum degree of protection to be achieved at each barrier or partition is to IP2X
as specified in the Ingress Protection standard EN 60529. Typically, this may include:
PVC sleeving, wrapping or plastic coating of conductors
Insulated terminal shrouds or PVC boots
Rigid insulated barriers or partitions
Compartments formed from earthed metal
A devices integral housing
There are several forms of separation, indicated by numbered category and subcategory; however the requirements for the degree of separation need to be
carefully considered since the cost increases significantly with increased degree.
The principal categories are:
Form 1 no separation
Typical applications are where the assembly is to be placed in a secure location
and where failure will cause little or no additional disruption to other areas being
supplied by that particular assembly.
Form 2 separation of busbars from functional units
Applications may be similar to those of Form 1 but where it is important that a fault
need not affect all functional units being supplied by the same busbar system.
Form 3 separation of busbars from functional units and the functional units
from one another, but not their terminations
This form should be applied where it is important to provide protection from
internal live parts and where failure of functional units being supplied from the
same busbar would cause unacceptable disruption.
Form 4 separation of busbars from functional units and the functional units
from one another, including their terminals
This form should be applied where it is important to provide protection from
internal live parts and where failure of functional units being supplied from the
same busbar would cause unacceptable disruption. Because all the terminations are
separated, it is possible to isolate and work on a single functional unit.
Dorman Smith LF-type panel board systems are supplied in Form 2 as standard,
with Form 4 versions achieved with simple conversion kits. However, other
separation forms can be provided in special cases.
With the exception of Form 1, the other separation forms have sub-categories that
permit permutations of the general form to be configured according to the
requirements for specific applications and to allow the accommodation of different
types of protection method. The exact form of separation provided on an assembly
is a matter for agreement between the manufacturer and the end user.

167

Sub-categories of Separation Forms


Main criteria

Sub criteria

No separation
Separation of
busbars from
the functional
units

Construction

1
Terminals for external
conductors not
separated from
busbars

2a

Terminals for external


conductors separated
from busbars

2b

Separation of
busbars from the
functional units
and separation of
all functional units
from one another.
Separation of the
terminals for external
conductors from
functional units but
not from each other

Terminals for external


conductors not
separated from busbars

3a

Terminals for external


conductors separated
from busbars

3b

Separation of
busbars from the
functional units and
separation of all
functional units
from one another
including terminals
for external
conductors which
are an integral
part of the
functional unit

Terminals for external


conductors in the
same compartment
as the associated
functional unit

1
2

1
2

Busbar separation by
insulated coverings
Busbar separation by
rigid barriers

Busbar separation by
insulated coverings
Busbar separation by
rigid barriers

Busbar separation by insulated


coverings
Cables may be glanded elsewhere

Busbar separation by rigid barriers


Cables may be glanded elsewhere

4a
3

Terminals for external


conductors not in the
same compartment as
the associated
functional unit but in
individual, separate,
enclosed protected
spaces or
compartments

168

Form Type

All separation by rigid barriers


The termination for each
functional unit has its own integral
glanding facility
Busbar separation by insulated
coverings
Cables may be glanded elsewhere

Busbar separation by rigid barriers


Terminals may be separated by
insulated coverings and glanded
in common cabling chambers

All separation by rigid barriers


Cables are glanded in common
cabling chambers

All separation by rigid barriers


The termination for each
functional unit has its own integral
glanding facility

4b

Ingress Protection
The EN 60529 standard describes a system for classifying degrees of protection
against the ingress of foreign bodies and harmful liquids. It is intended that this
standard is applied to enclosures of low voltage (LV) electrical equipment. The
classification scheme comprises a designation prefixed by the upper case letters
IP, followed by two numerals.
The first numeral designates the degree of protection with regard to solid objects;
the second numeral indicates the degree of protection against the ingress of liquid.
Compliance to the standard is intended to:
protect persons against access to hazardous parts inside enclosures and protect
the equipment inside the enclosure against the ingress of solid foreign objects.
protect the equipment inside the enclosure against harmful ingress of liquids.

IP

Protection

No protection

Full entry of 50mm


sphere, but no
contact with
hazardous parts

Equivalent

Back of
hand

Full entry of 12.5mm Finger


sphere not allowed,
but no contact with
hazardous parts with
jointed test finger

2.5mm diameter
access probe shall
not enter

1mm diameter access Wire


probe shall not enter

Limited ingress of
dust (no harmful
deposit)

Wire

Total protection
against dust ingress

Wire

Not tested

IP

Protection

No protection

Against vertically
falling water drops

Vertical
drips

As in 1, but with
enclosure tilted 15
degrees from vertical

Slanted
dripping
to 15
degrees
from
vertical

Against spray to 60
degrees from
vertical limited
ingress permitted

Limited
spray

Against splashing
from any direction
limited ingress
permitted

Splashing
from any
direction

Against low pressure


jets from any
direction limited
ingress permitted

Hosing
jets from
any
direction

Against strong jets


from any direction

Power
hosing
from any
direction

Against immersion
up to one metre

Temporary
immersion

Against prolonged
immersion under
pressure

Continuous
immersion

Not tested

Tool

Equivalent

For assemblies for indoor use where there is no requirement for the protection
against ingress of water, the following IP codes are preferred: IP00, IP2X, IP3X,
IP4X, IP5X, IP6X.

169

Insulation Distances for Loadline YA


Frame MCCBs
The insulation distances between an MCCB and adjacent earthed metal parts and
insulators shown in the diagram below must be maintained to prevent arcing faults
occurring due to conductive ionised gases. In cases where requirements differ from
those illustrated here, the greater distance must be maintained. Where two
different YA frame devices are installed one above the other, the insulation
distance between the two should be as for the lower size of MCCB.
Exposed conductors must be insulated up to the barrier terminals. Interphase
barriers or terminal covers are recommended. However, if terminal covers are used,
the exposed conductor must be insulated until it overlaps the terminal cover.

4. Front connected MCCB

A. Distance from lower breaker to exposed


live part of upper breaker terminal (front
connected type) or from lower breaker to
end face of upper breaker (rear connected
or plug-in type)

5. Front connected MCCB with


terminal bar

B1. Distance from end face of breaker to


top plate

6. Rear connected type or


plug-in type

B2. Distance from end face of breaker to


insulation plate

7. Side panel (earthed metal)

C.

1. Insulation plate
2. Top plate (earthed metal)
3. Interphase barriers

Gap between breakers

D. Distance from side of breaker to side panel


E.

MCCB

170

Dimensions of insulation over exposed


conductors

Distances

Frame
Size

Poles

B1

B2

YA2N

50

10

10

25

*(1)

YA2N

3/4

50

10

10

25

*(1)

YA2S

3/4

50

10

10

25

*(1)

YA2J

3/4

75

45

25

25

*(1)

YA3N

50

40

40

50

*(1)

YA3N

3/4

50

40

40

50

*(1)

YA3S

3/4

50

40

40

50

*(1)

YA3J

3/4

100

80

60

50

*(1)

YA5N

3/4

100

80

60

80

*(1)

YA5H

3/4

100

80

60

80

*(1)

*Note: (1) Insulate the exposed conductor until it overlaps the moulded case at the
terminal or terminal cover.

Loadline YA2 Frame MCCB Characteristics

YA2 1-pole Time/Current Characteristic

YA2 1-pole Energy Let-through

YA2 3 and 4-pole Time/Current Characteristic

YA2 3 and 4-pole Energy Let-through

171

Loadline YA3 Frame MCCB Characteristics

2500+/-500

YA3 1-pole Time/Current Characteristic

YA3 1-pole Energy Let-through

172

YA3 3 and 4-pole Time/Current Characteristic

YA3 3 and 4-pole Energy Let-through

Loadline YA5 and Y6 Frame MCCB Characteristics

YA5 3 and 4-pole Energy Let-through

YA5 3 and 4-pole Time/Current Characteristic

173
Y6 Time/Current Characteristic

Loadline Y7 and Y8 Frame MCCB


Characteristics

Y7 Time/Current Characteristic

4
3

I1

IP

2
1
50
40
30

T1
IG

I2

T2

TG

20

I3

Curves based on standard settings

10
8
6
5
4
3

2
1
50
40
30
20
10
8
6
5
4
3
2
1
0.8
0.6
0.5
0.4
0.3
0.2
0.1
0.08
0.06
0.05
0.04
0.03

Percent rated current of base current (I0)

Y8 Time/Current Characteristic

174

3000

2500

2000

1500

700
800
900
1000

600

500

400

300

250

200

150

125

50
80
90
100

20
40

15

8
9
10

0.01
0.008
0.006
0.005

12.5

0.02

Section

Products & Parts Locator

10

2IP-7-0244
3C345 01
3G365 02
AV2100
AV2125
AV3100
AV3125
AV363
AV4100
AV4125
AV463
CBT-94F-035
CBT-94F-070
CBT-94F-105
CBT-94F-140
CI1-01-PUL
CI3-01-PUL
CI-MOD-01
CI-PUL-01
DA06X
DA09X
DA12X
DA15X
DA18X
DA22X
DAS08X
DAS11X
DAS14X
DAS17X
DAS20X
DAS24X
DAXD1
DAXEB
DAXEB
DAXSK08
DAXSK11
DAXSK14
DAXSK17
DAXSK20
DAXSK24
DAXTP
DBMSB
DBS18X
DBS36X
DBTE04X
DBTE06X
DBTE08X
DBTE12X
DBTE16X
DBTE20X
DBTE24X
DBX04R
DBX06R
DBX08R
DBX12R
DBX16R

176

116
124, 125
124, 125
9,
9,
20,
20,

118
118
118
118
118
20, 118
20, 118
118
123
123
123
123
25, 51, 67, 124
25, 51, 67, 124
25, 51, 67, 124, 125
25, 51, 67, 124, 125
8
8
8
8
8
8
8
8
8
8
8
8
9
8
19
8
8
8
8
8
8
19
18, 26
18
18
19
19
19
19
19
19
19
18
18
18
18
18

DBX20R
18
DBX24FK
19
DBX24R
18
DBX24WL
19
DBXBH
8, 11, 19
DBXBM
8, 11, 19
DBXBP
8, 11, 19
DBXC06NAH06CA
27
DBXC06NAV04CA
27
DBXC08NAV06CA
27
DBXC08NJV06CJ
27
DBXC08NNV06CA
27
DBXC12NAH12CA
27
DBXC12NAV08CA
27
DBXC12NJV08CJ
27
DBXC12NNV08CA
27
DBXCKR
20
DBXCL
8, 19, 38, 39, 41, 60
DBXD0
9, 21
DBXD1
21
DBXD2
21
DBXE08NAH08NA
27
DBXE08NAV06NA
27
DBXE08NJV06NJ
27
DBXE12NAV08NA
27
DBXE12NJV08NJ
27
DBXEP
19
DBXJK
19
DBXL
8, 19
DBXLSA1
20
DBXLSA2
20
DBXPL
8, 19, 38, 39, 41, 60
DBXSKA
19
DBXT06
19
DBXT12
19
DBXT18
19
DBXT24
19
DBXTS
19
DBXW16
26
DBXW16T
26
DBXW24
26
DBXWP125
26
DBXWP250
26
DBXYA3
18
DRK-1P-230-D63
25, 127
DRK-1PCT-240
127
DRK-3P-400-D100
25, 127
DRK-3PCT-415
11, 25, 40, 127
DRK-3PCT-415-LCD
11, 25, 127
DRT-DW2R
24, 118
DSPE600
116
DSPE600N
116
DSPE600R
116
DSPM1P
115
DSPM1PN
9, 115
DSPM1PNR
115
DSPM3P
115
DSPM3PN
21, 115
DSPM3PNR
115
DSPML
9, 21, 115

DSPMNE
DSPT3PN
EE100/100/2
EE100/100/4
EE100/30/2
EE100/30/4
EE100/300/4
EE2P20CC
EE2P20CO
EE40/100/2
EE40/100/4
EE40/30/2
EE40/30/4
EE40/300/4
EE4P25CC
EE4P25CO
EE4P40CC
EE4P40CO
EE4P63CC
EE4P63CO
EE63/100/2
EE63/100/4
EE63/30/2
EE63/30/4
EE63/300/2
EE63/300/4
EE80/30/2
EES100/100/2
EES100/100/4
EES63/100/4
ELR1

9, 21, 115
117
9,
20,
9,
20,
20,

24, 97
24, 97
24, 97
24, 97
24, 97
24, 118
24, 118
97
20, 24, 97
24, 97
20, 24, 97
97
24, 118
24, 118
24, 118
24, 118
24, 118
20, 24, 118
9, 24, 97
20, 24, 97
9, 24, 97
20, 24, 97
9, 24, 97
20, 24, 97
9, 24, 97
9, 24, 97
20, 24, 97
20, 24
122

FS2

85, 87

HB125CSB
HB200CSB
HB400CSB
HB800CSB
HBE3P32N
HBF3P100N
HBF3P100N
HBF3P125N
HBF3P160N
HBF3P200N
HBF3P200N
HBF3P63N
HBF4P100
HBF4P200
HBK3P315N
HBL3P400N
HBL4P400
HBN3P630N
HBN3P800N
HBN4P800
HEL32
HFL200A
HFL63
HLL400
HNL800

85
85
85
85
84
84
20
84
84
84
20
84
84
84
84
84
84
84
84
84
85
85, 87
85, 87
85, 87
85, 87

49,
49,
49,
49,

HS13P20
HS13P20N
HS13P32
HS13P32N
HS13P40
HS13P40N
HS13P63
HS13P63N
HS23P100
HS23P100N
HS23P125
HS23P125N
HS23P63
HS23P63N
HSAUX
HSNL125
HSNL63
HSTS1125
HSTS163
HSTS3125
HSTS363
INT-1630-M-5-M-000
INT-1630-M-5-M-100
INT-1630-M-5-M-110

K1PB06
K1PB10
K1PB13
K1PB16
K1PB20
K1PB25
K1PB32
K1PB40
K1PB50
K1PB63
K1PC06
K1PC10
K1PC13
K1PC16
K1PC20
K1PC25
K1PC32
K1PC40
K1PC50
K1PC63
K1PD06
K1PD10
K1PD13
K1PD16
K1PD20
K1PD25
K1PD32
K2PB06
K2PB10
K2PB16
K2PB20
K2PB25

91
91
91
91
91
91
91
91
91
91
91
91
91
91
92
92
92
92
92
92
92
126
25, 51, 67,
126
25, 51, 67,
126
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,

22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,
22,

94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94

K2PB32
K2PB40
K2PB50
K2PB63
K2PC06
K2PC10
K2PC16
K2PC20
K2PC32
K2PC40
K2PC50
K2PC63
K2PD06
K2PD10
K2PD16
K2PD20
K2PD25
K2PD32
K3PB06
K3PB10
K3PB13
K3PB16
K3PB20
K3PB25
K3PB32
K3PB40
K3PB50
K3PB63
K3PC06
K3PC10
K3PC16
K3PC20
K3PC25
K3PC32
K3PC40
K3PC50
K3PC63
K3PD06
K3PD10
K3PD16
K3PD20
K3PD25
K3PD32
KAUX1
KDL
KR1PB0630
KR1PB1030
KR1PB1630
KR1PB2030
KR1PB3230
KR1PB4030
KR1PB4530
KR1PC06100
KR1PC0630
KR1PC10100
KR1PC1030
KR1PC16100
KR1PC1630
KR1PC20100
KR1PC2030

94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22,94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
22, 94
11, 23, 95
11, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95
10, 23, 95

KR1PC32100
KR1PC3230
KR1PC40100
KR1PC4030
KR1PC4530
KR2PB0630
KR2PB1030
KR2PB1630
KR2PB2030
KR2PB3230
KR2PB4030
KR2PC0630
KR2PC1030
KR2PC1630
KR2PC2030
KR2PC3230
KR2PC4030
KST240
LB1F2A
LB1F4A
LB1Y6
LB1Y7
LB1YA3
LB406YA3
LB412YA3
LB418YA3
LB802YA5
LB806YA3
LB812YA3
LB818YA3
LBBP3PYA3
LBCK4
LBCK8
LBDD06
LBDD12
LBDD18
LBDR4
LBDR8
LBSKE
LBWCT
LBWI
LBWM6
LBWP
LBYA2BP3P
LCFVK
LD1D06X
LD1D12X
LD1DS
LD2D12X
LDS17
LDS24
LDT106X
LDT112X
LDT212X
LEBM1
LEBM2
LEBM2
LEBM3
LEBM4
LEBM5

10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
10,
11,

23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,
23,

95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
95
60
60
60, 61
61
60
60
60
60
62, 66
61
61
61
60, 61
60
60, 61, 66
60, 61
60, 61
60, 61
60
61
60, 61
51, 67
51, 67
51, 67
51, 67
38, 39, 41
48, 64
50, 66
50,66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66
50, 66

177

LEBM6
LECK2SM
LECK2SP
LECM1
LECM2
LECM3
LECM4
LECM5
LECM6
LECM8
LECMD2
LECMD3
LECMD4
LECMD5
LECMD6
LECMD8
LF1F4A
LF1F8A
LF806A
LF806YA
LF810A
LF810YA
LFS41A
LFS41YA
LFS42A
LFS42YA
LFXHBA
LGES
LGES
LLMV
LM10
LM20
LM30
LM3P20
LM3P30
LM40
LM50
LM60
LMMB2
LMMB3
LW3
M30-DINCLIP
M30-DINCLIP
M3N1-25-100/5
M3N1-25-125/5
M3N1-25-160/5
M3N1-25-60/5
M3N1-35-100/5
M3N1-35-125/5
M3N1-35-160/5
M3N1-35-200/5
M3N1-35-250/5
M3N1-45-250/5
M3N1-45-250/5
M3N1-45-300/5
M3N1-45-400/5
M3N1-45-400/5
M3N1-45-500/5
M3N1-45-630/5

178

50, 66
50, 67
50, 67
50, 67
50, 67
50, 67
50, 67
50, 67
50, 67
50, 67
51, 67
51, 67
51, 67
51, 67
51, 67
51, 67
48, 64
48, 64
48
64
48
64
48
64
48
64
48
60
61
24, 118
114
114
114
114
114
114
114
114
114
114
114

40,
40,
40,
26, 51, 67,
26, 51, 67,

11
119
120
120
120
120
120
120
120
26
26
40
120
120
40
120
120
120

M50-DINCLIP
M53J-100/5D
M53J-125/5D
M53J-200/5D
M53J-250/5D
M53Q-100/5
M53Q-125/5
M55E-30/5
M55E-60/5
M63N-400/5
M63N-600/5
M93L-600/5
M93L-800/5
MB5D-800/5
MCFMY6
MMS15Y
MXD06
MXD10
MXEPF
PB206YA
PB208YA
PB212YA
PB406YA
PB408YA
PB412YA
PB416YA
PB4PNC250
PB4PNC400
PBSM
PBWCT
PBWI
PBWM6
PBWP
PBYA2CSB
PBYA2MB
PBYA2OG
PBYA2SC24
PS100NY
PS125NY
PS16NY
PS25NY
PS32NY
PS40NY
PS63NY
PS80NY
RI3-01
S1PB06
S1PB10
S1PB16
S1PB20
S1PB25
S1PB32
S1PB40
S1PB50
S1PB63
S1PC06
S1PC10

119
119
119
119
119
11, 119
11, 119
119
119
51, 67, 119
51, 67
119
51, 67
119
64
64
48, 64
48, 64
60
38
38
38
39
39
39
39
38, 41
39, 41
40
40
40
40
40
38
40
38
38
90
90
90
90
90
90
90
90
11, 25, 40, 128
96
96
96
96
96
96
96
96
96
96
96

S1PC16
S1PC20
S1PC25
S1PC32
S1PC40
S1PC50
S1PC63
S1PD06
S1PD10
S1PD16
S1PD20
S1PD25
S1PD32
S1PD40
S1PD50
S1PD63
S2PB06
S2PB10
S2PB16
S2PB20
S2PB25
S2PB32
S2PB40
S2PB50
S2PB63
S2PC06
S2PC10
S2PC16
S2PC20
S2PC25
S2PC32
S2PC40
S2PC50
S2PC63
S2PD06
S2PD10
S2PD16
S2PD20
S2PD25
S2PD32
S2PD40
S2PD50
S2PD63
S3PB06
S3PB10
S3PB16
S3PB20
S3PB25
S3PB32
S3PB40
S3PB50
S3PB63
S3PC06
S3PC10
S3PC16
S3PC20
S3PC25
S3PC32
S3PC40
S3PC50

96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96
96

S3PC63
S3PD06
S3PD10
S3PD16
S3PD20
S3PD25
S3PD32
S3PD40
S3PD50
S3PD63
SAUX2F
SAUX2N
SAUX4F
SAUX4N
SAUX6N
SC1-100/5A
SC1-150/5A
SC1-200/5A
SC1-250/5A
SC1-300/5A
SC1-400/5A
SC2-250/5A
SC2-300/5A
SC2-400/5A
SC3-1000/5A
SC3-250/5A
SC3-300/5A
SC3-400/5A
SC3-500/5A
SC3-600/5A
SC3-750/5A
SC3-800/5A
SC4-1000/5A
SC4-1200/5A
SC4-1250/5A
SC4-1500/5A
SC4-1600/5A
SC4-500/5A
SC4-600/5A
SC4-750/5A
SC4-800/5A
SCLK
SF1P100N
SF1P125N
SF1P160N
SF1P200N
SF3P100N
SF3P125N
SF3P160N
SF3P200N
SF3P63N
SF4P100
SF4P125
SF4P160
SF4P200
SF4P63
SFFS125
SFFS200
SFTB
SFTSL

96
96
96
96
96
96
96
96
96
96
49, 85, 87
49, 85, 87
49, 85, 87
49, 85, 87
49, 85, 87
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
121
85, 87
49
49
49
49
49, 86
49, 86
49, 86
49, 60, 86
49, 86
49, 86
49, 86
49, 86
49, 60, 86
49, 86
87
87
49, 87
87

SFTSS
SHA1
SHA2
SHA3
SHA4
SK3P315N
SK4P315
SKFS
SKTB
SKTS
SL3P400N
SL4P400
SL4P400N
SLFS
SLTB
SLTS
SN3P630N
SN3P800N
SN4P630
SN4P630N
SN4P800
SN4P800N
SNCET
SNFS
SNTS
SRLB100
SRLB125
SRLB160
SRLB200
SRLB315
SRLB400
SRLB63
SRLB630
SRLB800
SXT127
SXT160
SXT227
SXT260
T1PD40
T1PD50
T1PD63
T2PD40
T2PD50
T2PD63
T3PD40
T3PD50
T3PD63
XPL
Y2DL
Y5CF
Y5DCLCAM
Y5TB3P
Y5TB4P
Y6AC400
Y6AC630
Y6AC800
Y6AUX1

49, 87
87
87
87
87
86
86
87
87
87
48, 60, 64, 86
48, 60, 86
64
87
49, 87
49, 87
48, 66, 86
48, 66, 86
48, 86
66
48, 86
66
48, 49, 66, 87
87
49, 87
87
87
87
87
87
87
87
87
87
87
87
87
87
10, 22, 94
10, 22, 94
10, 22, 94
94
94
94
22, 94
22, 94
22, 94
11, 23, 95
41
110
110, 112, 113
110, 112, 113
110, 112, 113
111
111
111
110

Y6AUX2
Y6AUXAL
Y6B3P400D
Y6B3P630D
Y6B3P800D
Y6B4P400D
Y6B4P630D
Y6B4P800D
Y6CC4P
Y6CLDS1
Y6CLDS2
Y6DL
Y6H3P400T5
Y6H3P630E
Y6H3P630T5
Y6H3P800E
Y6H3P800T5
Y6H4P400T5
Y6H4P630E
Y6H4P630T5
Y6H4P630T5
Y6H4P800E
Y6H4P800T5
Y6HE
Y6J3P630E
Y6J3P800E
Y6J4P630E
Y6J4P800E
Y6K3P400T5
Y6K3P630T5
Y6K3P800T5
Y6K4P400T5
Y6K4P630T5
Y6K4P800T5
Y6MA110
Y6MA240
Y6MMS
Y6MR
Y6MW10
Y6MW15
Y6NL
Y6RH1
Y6RH2
Y6ST115AC
Y6ST24DC
Y6ST480AC
Y6TS3P
Y6TS4P
Y6UVR120AC
Y6UVR240AC
Y6UVR24DC
Y6UVR450AC
Y7AUX3P1
Y7AUX3P2
Y7AUX3PAL
Y7AUX4P1
Y7AUX4P2
Y7AUX4PAL
Y7B3P1250D
Y7B3P800D

110
110
60, 66
60, 109
109
60, 66
60, 109
109
110
110
110
110
60, 66, 109
109
60
109
66, 109
60, 66, 109
109
60
66, 109
109
66, 109
110
109
109
109
109
109
109
109
109
109
109
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112
60

179

Y7B4P1250D
Y7B4P800D
Y7CL
Y7DL
Y7J3P1000E
Y7J3P1250E
Y7J4P1000E
Y7J4P1250E
Y7MA110
Y7MA240
Y7NL
Y7ST115AC
Y7ST24DC
Y7ST480AC
Y7TS3P
Y7TS4P
Y7UVR120AC
Y7UVR240AC
Y7UVR24DC
Y7UVR450AC
Y8B3P1600D
Y8B3P1600DDO Y8B3P1600DR Y8B4P1600D
Y8K3P1600E
Y8K3P1600EG
Y8K3P1600ER
Y8K4P1600E
YA2CC3P
YA2J3P100T
YA2J3P125T
YA2J3P20T
YA2J3P32T
YA2J3P50T
YA2J3P63T
YA2J4P100T
YA2J4P125T
YA2J4P20T
YA2J4P32T
YA2J4P50T
YA2J4P63T
YA2N1P100T
YA2N1P125T
YA2N1P16T
YA2N1P20T
YA2N1P32T
YA2N1P40T YA2N1P50T
YA2N1P63T
YA2N1P80T
YA2N3P100T
YA2N3P125T
YA2N3P20T
YA2N3P32T
YA2N3P50T
YA2N3P63T
YA2N4P100T
YA2N4P125T
YA2N4P20T
YA2N4P32T

180

112
60
112, 113
112, 113
60, 112
112
60, 112
112
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
112, 113
113
113
113
113
113
113
113
113
41
103
103
103
103
103
103
103
103
103
103
103
103
103, 41
103, 41
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
41, 103
103
103
103
103

YA2N4P50T
YA2N4P63T
YA2S3P100T
YA2S3P125T
YA2S3P50T
YA2S3P63T
YA2S4P100T
YA2S4P125T
YA2S4P50T
YA2S4P63T
YA2TS1P
YA2TS3P
YA34J100T
YA34J125T
YA34J160T
YA34J200T
YA34J250T
YA34J63T
YA3B3P250D
YA3B4P250D
YA3CC3P
YA3CC4P
YA3F4BP
YA3J3P100T
YA3J3P125T
YA3J3P160T
YA3J3P200T
YA3J3P250T
YA3J3P50T
YA3J3P63T
YA3MA110
YA3MA240
YA3ML
YA3MMS
YA3MW10
YA3MW15
YA3N1P100T
YA3N1P125T
YA3N1P160T
YA3N1P16T
YA3N1P20T
YA3N1P32T
YA3N1P40T
YA3N1P50T
YA3N1P63T
YA3N1P80T
YA3N3P100T
YA3N3P125T
YA3N3P160T
YA3N3P200T
YA3N3P20T
YA3N3P250T
YA3N3P32T
YA3N3P50T
YA3N3P63T
YA3N4P100T
YA3N4P125T

103
103
103
103
103
103
103
103
103
103
41
41
105
105
105
105
105
105
21, 38, 60, 105
21, 38, 60, 105
41, 62, 106
62, 106
64
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
106
106
106
106
106
106
62, 105
62, 105
62, 105
62, 105
62, 105
62, 105
62, 105
62, 105
62, 105
62, 105
21, 62, 65, 105
21, 62, 65, 105
21, 38, 60, 62,
65, 105
21, 38, 60, 62
65, 105
62, 65, 105
21, 38, 60, 62
65, 105
62, 65, 105
62
21, 62, 65, 105
21, 105
21, 105

YA3N4P160T
YA3N4P200T
YA3N4P20T
YA3N4P250T
YA3N4P32T
YA3N4P50T
YA3N4P63T
YA3NL
YA3PB3P
YA3PB4P
YA3PRA3P
YA3PRA4P
YA3PT3P
YA3PT4P
YA3PXT3P
YA3PXT4P
YA3R1
YA3R2
YA3RT3P
YA3RT4P
YA3S3P100T
YA3S3P125T
YA3S3P160T
YA3S3P200T
YA3S3P250T
YA3S3P50T
YA3S3P63T
YA3S4P100T
YA3S4P125T
YA3S4P160T
YA3S4P200T
YA3S4P250T
YA3S4P50T
YA3S4P63T
YA3TB
YA3TS1P
YA3TS1P
YA3TS3P
YA3TS3PS
YA3TS4P
YA3XT4P
YA5B3P400D
YA5B4P400D
YA5CC3P
YA5CC4P
YA5DL
YA5H3P250T
YA5H3P400T
YA5H4P250T
YA5H4P400T
YA5J3P250T
YA5J3P400T
YA5J4P250T
YA5J4P400T
YA5K3P250E
YA5K3P400E
YA5K4P250E
YA5K4P400E
YA5MA110
YA5MA240

21, 38, 60, 105


21, 38, 60, 105
105
21, 38, 60, 105
105
63, 105
21, 105
18, 60
106
106
106
106
106
106
106
106
106
106
106
106
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
62, 65, 105
105
105
105
105
105
105
105
106
41, 106
106
38, 41, 62, 106
106
38, 41, 62, 106
106
39, 107
39, 107
41, 62, 108
62, 108
108
62, 107
62, 107
62, 107
62, 107
107
107
107
107
107
107
107
107
108
108

Das könnte Ihnen auch gefallen