Sie sind auf Seite 1von 2

datasheet

1065 ELEVATOR CONTROLLER


Key Features
16 on-board supervised
inputs (4-state, dual endof-line)
Four on-board outputs (2 x
relay, 2 x open-emitter)
Two on-board expansion
ports (for Pacom I/O
expansion cards)

Secure elevators with Pacom control.

The 1065R-EC-UL is used to control access to floors


serviced by an elevator, where a low-level elevator interface
is used. This is performed by interrupting the wiring
between the elevator and its control panel using relays,
so that the Pacom system determines whether or not the
elevator can be accessed, and may also determine which
floors can be selected. Generally, a card reader is installed
in the elevator car and when a valid card is swiped, the
selection buttons for floors authorized for that cardholder
can be activated. Once a floor selection button is pressed,
no other floor can be selected.
The 1065R-EC-UL requires 1050R-003-UL 8-output
expansion card(s) in order to have the required relays for
full floor selection control. It may also be used without
expansion cards, where it controls access to the elevator
only, allowing the user to select any floor once their access
card is validated.

The 1065R-EC-UL also supports apartment operation.


In this scenario, the person in the apartment can press
a button to allow a visitor access to the floor that the
apartment is on. When the visitor enters the elevator, only
the floor that has granted the access is selectable.
When connected to a Controller, each 1065R-EC-UL can
control access to up to 16 consecutively numbered floors.
If an elevator services non-consecutive floors (for example,
floor 1 and floors 20-30), although it may be less than 16
floors in total, it may require two 1065R-EC-UL devices one for each group of 16.
The 1065-EC communicates with the Controller over an
RS485 multi-drop device loop. A 1058 Controller can control
access for up to two elevators. 1057 and 8000 series
Controllers can control access for up to 16 elevators (all
Controllers have a limit of 128 floors per elevator).

System Architecture

Inputs from
floor selection
buttons

Pacom
Controller

1065
Elevator
Controller

RS485

Outputs to
elevator system

Technical Specifications
Dimensions: 172 x 118mm (6.8 x 4.6).
Weight: 150g (5.3oz).
Operating Environment: [EU] -10 to 50C (14 to
122F)/[US] 0 to 50C (32 to 122F), 85% relative
humidity (non-condensing).
Power Input: 9 to 15VDC, 100mA (can be supplied by
Controller or external power supply).
Auxiliary Power: 12VDC, 200mA maximum per open
emitter output when powered by Controller/12VDC, 1A
maximum per relay output when powered by external
power supply.

Power Consumption: 110mA @ 12VDC (typical,


excluding attached devices). 135mA maximum with all
alarm conditions present and all outputs active.
Inputs: 16 x 3.3-25.4k end-of-line (EOL) supervised
(10k default). All inputs can be configured as analog.
Outputs: Four - 2 x relay/2 x open-emitter.
Expansion Slots: Two.
Communication: Two-wire RS485.

Compliance/Accreditation
RoHS, A-Tick.
Radiation: FCC Part 15.

Safety: C-Tick, CE Safety.

Order Information
Part Number

Type Code

Description

300 072 011

1065R-EC-UL

1065 elevator controller (PCB only).

DS-031-V1
Specifications subject to change without notice. Copyright Pacom Systems

Page 2

Das könnte Ihnen auch gefallen