Beruflich Dokumente
Kultur Dokumente
REFERENCE
NSCP 2010 -6th
Edition
(4th Printing)
Table 204-2
(NSCP 6th edition 4th printing)
Component
Material
Load
Ceiling
Suspended
Metal Lath and
Cement Plaster
0.72 KPa
24 KN/m3
Concrete
Floor fill
Lightweight
concrete
0.015 KPa
Floor finish
1.10 KPa
Exterior walls
3.59 KPa
Interior partition
600mm Grout
Spacing (16.5
KN/m3 , 150 mm
wythe)
1.63 KPa
Water Proofing
Liquid, applied
0.05 KPa
Coverings, Roof
Deck, metal
gage 20
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS
0.12 KPa
SUBMITTED BY:
NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON
DATE:
09/17/2015
Pag
e
2
Of
6
Page
1
Of
11
REFERENCE
B. LIVE LOAD
Live loads are usually unstable or moving loads. These
dynamic loads
may involve considerations such as impact, momentum,
vibrations, slosh
dynamics of fluids and etc. Live loads shall be the maximum load expected by
the intended use or occupancy but in no case shall be less than the loads
required by this section.
Residential
Uniform Load
(KPa)
1.9
Concentrated
Load
(KN)
0
Exterior
Balconies
Decks
2.9
1.9
Table 205-1
(NSCP 6th edition 4th printing)
C. WIND LOAD
Building, towers and other vertical structures including
the main
Figure 207-1
(NSCP 6th edition 4th printing)
Zone II
V = 200kph
D. SEISMIC LOAD
The phillipine archipelago is divided into two seismic
zones only. Zone 2
covers the provinces of Palawan, Sulu, tawi-tawi while the rest
of the countrys
part is under zone 4. Each structure shall be assigned a
seismic zone factor Z.
Figure 208-1
(NSCP 6th edition 4th
printing)
Referenced Seismic
Map of the Philippines
(Page 2-86)
Zone 4
0.4
SUBMITTED BY:
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS
NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON
DATE:
09/17/2015
Occupancy
Category1
I. Essential
Facilities3
II. Hazardous
Facilities
III. Special
Occupancy
Structures
IV. Standard
Occupancy
Structures
V. Miscellaneous
structures
Seismic
Importance
Factor, I
1.50
Seismic
Importance2
Factor, Ip
1.50
1.25
1.50
1.00
1.00
1.00
1.00
1.00
1.00
REFERENCE
NSCP 2010 -6th
Edition
(4th Printing)
Pag
e
3
Of
6
SEISMIC PARAMETERS
SUBMITTED BY:
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS
NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON
DATE:
09/17/2015
Table 208-1
(NSCP 6th edition 4th printing)
REFERENCE
NSCP 2010 -6th
Edition
(4th Printing)
Soil Profile
Type
SA
SB
SC
Soil Profile
Name/Generic
Description
SPT,N(blows/
300mm)
Hard rock
>1500
Rock
760 to 1500
>50
Very Dense Soil
360 to 760
and Soft Rock
15 to 50
Stiff ZONE
Soil Profile
180 to
2 360
4
<15
Soft Soil
<180
Z Profile
.20
.40
Soil Requiring Site-specific Evaluation.
See Section 208.4.3.1
SD
SE1
SF
Table 208-2
Undrained Shear
Strength,Su(kPa)
>100
SEISMIC ZONE
(Page 2-83)
FACTOR, Z
50 to 100
<50
Table 208-3
(NSCP 6th edition 4th printing)
Pag
e
4
Of
6
Seismic
Source
Type
Closest Distance To
Known Seismic Source2
5 km
10 km
A
B
C
1.2
1.0
1.0
1.0
1.0
1.0
Table 208-5
(NSCP 6th edition 4th printing)
(Page 2-85)
SUBMITTED BY:
Near-Source Factor N
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS
1
V
NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON
DATE:
Table
09/17/2015
th
208-6
Seismic
Source
Type
Closest Distance To
Known Seismic Source2
5 km
10 km
15 km
REFERENCE
A
B
C
1.6
1.2
1.0
1.2
1.0
1.0
1.0
1.0
1.0
Seismic Coefficient Ca
Soil Profile
Type
SA
SB
SC
SD
SE
SF
Seismic Zone Z
Z=0.2
Z=0.4
0.16
0.32Na
0.20
0.40Na
0.24
0.40Na
0.28
0.44Na
0.34
0.44Na
See Footnote 1 of Table 208-8
Table 208-7
(NSCP 6th edition 4th printing)
Seismic Coefficient Ca
(Page 2-92)
Seismic Coefficient Cv
Soil Profile
Type
SA
SB
SC
SD
SE
SF
Seismic Zone Z
Z=0.2
Z=0.4
0.16
0.32Na
0.20
0.40Na
0.32
0.56Na
0.40
0.64Na
0.64
0.94Na
See Footnote 1 of Table 208-8
Table 208-8
(NSCP 6th edition 4th printing)
Seismic Coefficient CV
(Page 2-92)
Pag
e
5
Of
6
STRUCTURAL SYSTEM
SUBMITTED BY:
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS
NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON
DATE:
09/17/2015
Basic
SeismicForce
resisting
system
Lateral-Force
Resisting
System
Description
MomentResisting
frame
systems
Special
Reinforced
concrete
moment
frames
Intermediate
reinforced
concrete
moment
frames
Ordinary
reinforced
concrete
moment
frames
Table 208-11A
REFERENCE
(NSCP 6th edition 4th printing)
Height
Limit
for
Zone 4
Resisting Structural
Systems
of Concrete
(4th
Printing)
(Page 2-105)
8.5
2.8
NL
5.5
2.8
NP
3.5
2.8
NP
SUBMITTED BY:
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS
NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON
DATE:
09/17/2015
Pag
e
6
Of
6