CONCRETE

For columns, pile caps, footing tie beams, retaining walls,


stairs,

suspended slabs, beams, girders and elevator cores.


fc=21 MPa (3000 psi)

REFERENCE
NSCP 2010 -6th
Edition
(4th Printing)

For Slab on grade


fc=17 MPa (2500 psi)

DESIGN LOAD CRITERIA


A. DEAD LOAD
Dead loads includes load that are relatively constant
over time

Table 204-2
(NSCP 6th edition 4th printing)

including the weight of structure itself and immovable fixtures


such as
walls. Roof is also a dead load. Dead loads are also
known as permanent load.

Component

Material

Load

Ceiling

Suspended
Metal Lath and
Cement Plaster

0.72 KPa

Minimum Design Dead


Loads
(Page 2-82)

24 KN/m3

Concrete

Floor fill

Lightweight
concrete

0.015 KPa

Floor finish

Solid Flat Tile

1.10 KPa

Exterior walls

Full Grout (16.5


KN/m3 , 200 mm
wythe)

3.59 KPa

Interior partition

600mm Grout
Spacing (16.5
KN/m3 , 150 mm
wythe)

1.63 KPa

Water Proofing

Liquid, applied

0.05 KPa

Coverings, Roof

Deck, metal
gage 20

EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS

0.12 KPa
SUBMITTED BY:

NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON

DATE:
09/17/2015

Pag
e
2
Of
6

Page
1
Of
11

REFERENCE

B. LIVE LOAD
Live loads are usually unstable or moving loads. These
dynamic loads
may involve considerations such as impact, momentum,
vibrations, slosh

NSCP 2010 -6th


Edition
(4th Printing)

dynamics of fluids and etc. Live loads shall be the maximum load expected by
the intended use or occupancy but in no case shall be less than the loads
required by this section.
Residential

Uniform Load
(KPa)

Basic Floor Area

1.9

Concentrated
Load
(KN)
0

Exterior
Balconies
Decks

2.9

1.9

Table 205-1
(NSCP 6th edition 4th printing)

Minimum Uniform and


Concentrated Live Loads
(Page 2-16)

C. WIND LOAD
Building, towers and other vertical structures including
the main

Figure 207-1
(NSCP 6th edition 4th printing)

wind-force resisting system and all components and cladding


thereof shall
be designed and constructed to resist wind loads as specified

Design Wind Zone


Basic Wind Speed

Wind Zone Map of the


Philippines
(Page 2-26)

Zone II
V = 200kph

D. SEISMIC LOAD
The phillipine archipelago is divided into two seismic
zones only. Zone 2
covers the provinces of Palawan, Sulu, tawi-tawi while the rest
of the countrys
part is under zone 4. Each structure shall be assigned a
seismic zone factor Z.

Design Seismic Zone


Seismic Zone Factor

Figure 208-1
(NSCP 6th edition 4th
printing)

Referenced Seismic
Map of the Philippines
(Page 2-86)

Zone 4
0.4

E. DISTANCE FROM THE FAULT LINE


Table 208-3
(NSCP 6th edition 4th printing)

Seismic Zone Factor


(Page 2-85)

SUBMITTED BY:

EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS

NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON

DATE:
09/17/2015

Occupancy
Category1
I. Essential
Facilities3
II. Hazardous
Facilities
III. Special
Occupancy
Structures
IV. Standard
Occupancy
Structures
V. Miscellaneous
structures

Seismic
Importance
Factor, I
1.50

Seismic
Importance2
Factor, Ip
1.50

1.25

1.50

1.00

1.00

1.00

1.00

1.00

1.00

REFERENCE
NSCP 2010 -6th
Edition
(4th Printing)

Pag
e
3
Of
6

SEISMIC PARAMETERS
SUBMITTED BY:

EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS

NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON

DATE:
09/17/2015

Table 208-1
(NSCP 6th edition 4th printing)

Seismic importance factor


(Page 2-82)

REFERENCE
NSCP 2010 -6th
Edition
(4th Printing)

SEISMIC COEFFICIENT PROFILE TYPE

Average Soil Properties for Top 30 m of Soil Profile

Soil Profile
Type

SA
SB
SC

Soil Profile
Name/Generic
Description

Shear Wave Velocity, VS(m/s)

SPT,N(blows/
300mm)

(NSCP 6th edition 4th printing)

Soil Profile Types

Hard rock
>1500
Rock
760 to 1500
>50
Very Dense Soil
360 to 760
and Soft Rock
15 to 50
Stiff ZONE
Soil Profile
180 to
2 360
4
<15
Soft Soil
<180
Z Profile
.20
.40
Soil Requiring Site-specific Evaluation.
See Section 208.4.3.1

SD
SE1
SF

Table 208-2

Undrained Shear
Strength,Su(kPa)

>100

SEISMIC ZONE
(Page 2-83)
FACTOR, Z

50 to 100
<50

Table 208-3
(NSCP 6th edition 4th printing)

Seismic Zone Factor Z


(Page 2-85)

Pag
e
4
Of
6

Near-Source Factor Na1

Seismic
Source
Type

Closest Distance To
Known Seismic Source2
5 km

10 km

A
B
C

1.2
1.0
1.0

1.0
1.0
1.0

Table 208-5
(NSCP 6th edition 4th printing)

(Page 2-85)

SUBMITTED BY:

Near-Source Factor N
EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS

1
V

Near-Source Factor Na1

NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON

DATE:
Table
09/17/2015
th

208-6

(NSCP 6 edition 4th printing)

Near-Source Factor Nv1


(Page 2-85)

Seismic
Source
Type

Closest Distance To
Known Seismic Source2
5 km

10 km

15 km

REFERENCE

A
B
C

1.6
1.2
1.0

1.2
1.0
1.0

1.0
1.0
1.0

NSCP 2010 -6th


Edition
(4th Printing)

Seismic Coefficient Ca

Soil Profile
Type
SA
SB
SC
SD
SE
SF

Seismic Zone Z
Z=0.2
Z=0.4
0.16
0.32Na
0.20
0.40Na
0.24
0.40Na
0.28
0.44Na
0.34
0.44Na
See Footnote 1 of Table 208-8

Table 208-7
(NSCP 6th edition 4th printing)

Seismic Coefficient Ca
(Page 2-92)

Seismic Coefficient Cv
Soil Profile
Type
SA
SB
SC
SD
SE
SF

Seismic Zone Z
Z=0.2
Z=0.4
0.16
0.32Na
0.20
0.40Na
0.32
0.56Na
0.40
0.64Na
0.64
0.94Na
See Footnote 1 of Table 208-8

Table 208-8
(NSCP 6th edition 4th printing)

Seismic Coefficient CV
(Page 2-92)

Pag
e
5
Of
6

STRUCTURAL SYSTEM

SUBMITTED BY:

EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS

NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON

DATE:
09/17/2015

Basic
SeismicForce
resisting
system

Lateral-Force
Resisting
System
Description

MomentResisting
frame
systems

Special
Reinforced
concrete
moment
frames
Intermediate
reinforced
concrete
moment
frames
Ordinary
reinforced
concrete
moment
frames

Table 208-11A
REFERENCE
(NSCP 6th edition 4th printing)

Height
Limit
for
Zone 4

NSCP 2010 -6th


Earthquake-ForceEdition

Resisting Structural

Systems
of Concrete
(4th
Printing)
(Page 2-105)

8.5

2.8

NL

5.5

2.8

NP

3.5

2.8

NP

SUBMITTED BY:

EARTHQUAKE ANALYSIS
SEISMIC PARAMETERS

NBB,EJAB,ZDG,
ACDL,BAPL
CHECKED BY:
ENGR. M.B.BAYLON