Sie sind auf Seite 1von 9

Eco Audit Report

Product name

space heater

Country of use

United States

Product life (years)

Summary:

Energy details

Phase
Material
Manufacture
Transport
Use
Disposal
Total (for first life)
End of life potential

space heater.prd

CO2 footprint details


Energy
(J)
2.82e+08
0
1.87e+07
9.85e+11
4.23e+06
9.85e+11
-1.34e+08

Energy
(%)
0.0
0.0
0.0
100.0
0.0
100

CO2 footprint
(kg)
18.9
0
1.33
6.1e+04
0.296
6.1e+04
-9.63

NOTE: Differences of less than 20% are not usually significant.


See notes on precision and data sources.

CO2 footprint
(%)
0.0
0.0
0.0
100.0
0.0
100

Page 1 / 9
Wednesday, September 16,
2015

Eco Audit Report


Summary

Energy Analysis

Energy (J/year)
Equivalent annual environmental burden (averaged over 3 year product life):

3.28e+11

Detailed breakdown of individual life phases


Summary

Material:
Recycled
content*
(%)

Part
mass
(kg)

Qty.

Total mass
processed**
(kg)

Energy
(J)

Virgin (0%)

5.7

5.7

1.8e+08

64.8

Virgin (0%)

0.4

0.4

2.9e+07

10.4

Wrought iron

Virgin (0%)

0.13

0.13

3.2e+06

1.1

conductor

Copper, C10200, wrought, soft


(oxygen-free h.c. copper)

Virgin (0%)

0.08

0.08

4.7e+06

1.7

insulation

PE-LD (molding and extrusion) Virgin (0%)

0.08

0.08

6.4e+06

2.3

Virgin (0%)

0.35

0.35

2.7e+07

9.6

Virgin (0%)

0.09

0.09

4.8e+06

1.7

Virgin (0%)

0.22

0.22

2.4e+07

8.5

2.8e+08

100

Component

casting
heat shield
morter

connecting hose
hose conector
other

Material
Carbon steel, SA216 (Type
WCC), cast, normalized &
tempered
Stainless steel, austenitic,
AISI 321, wrought

Natural rubber (unreinforced)


Brass, CuZn39Pb2, C37700,
wrought, soft (leaded (forging)
brass)
PC (high viscosity, molding
and extrusion)

Total
*Typical: Includes 'recycle fraction in current supply'
**Where applicable, includes material mass removed by secondary processes

space heater.prd

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 2 / 9
Wednesday, September 16,
2015

Manufacture:

Summary

Component

Process

% Removed

Amount processed

Energy
(J)

Total

%
100

Summary

Transport:
Breakdown by transport stage
Transport type

Distance
(m)

Energy
(J)

land

32 tonne truck

6e+05

1.9e+06

10.3

sea

Sea freight

1.5e+07

1.7e+07

89.7

1.6e+07

1.9e+07

100

Mass
(kg)

Energy
(J)

casting

5.7

1.5e+07

80.7

heat shield

0.4

1.1e+06

5.7

morter

0.13

3.5e+05

1.9

conductor

0.08

2.1e+05

1.1

insulation

0.08

2.1e+05

1.1

connecting hose

0.35

9.4e+05

5.0

hose conector

0.09

2.4e+05

1.3

other

0.22

5.9e+05

3.1

Total

1.9e+07

100

Stage name

Total

Breakdown by components
Component

space heater.prd

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 3 / 9
Wednesday, September 16,
2015

Summary

Use:
Static mode
Energy input and output type
Country of use
Power rating
(W)

Mobile mode
Electric to thermal
United States
9.3e+03

Usage (hours per day)

24

Usage (days per year)

1.8e+02

Product life (years)

Fuel and mobility type


Country of use

United States

Product mass
(kg)

Distance
(m per day)

Diesel - heavy goods


vehicle

1e+05

Usage (days per year)

Product life (years)

Relative contribution of static and mobile modes


Mode

Energy
(J)

Static

9.8e+11

100.0

Mobile

Total

9.8e+11

100

Breakdown of mobile mode by components


Component

Energy
(J)

casting

heat shield

morter

conductor

insulation

connecting hose

hose conector

other

Total

space heater.prd

100

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 4 / 9
Wednesday, September 16,
2015

Summary

Disposal:
End of life
option

% recovered

Energy
(J)

casting

Recycle

100.0

4e+06

93.6

heat shield

Landfill

100.0

8e+04

1.9

morter

Landfill

100.0

2.6e+04

0.6

conductor

Landfill

100.0

1.6e+04

0.4

insulation

Landfill

100.0

1.6e+04

0.4

connecting hose

Landfill

100.0

7e+04

1.7

hose conector

Landfill

100.0

1.8e+04

0.4

other

Landfill

100.0

4.4e+04

1.0

4.2e+06

100

Component

Total

EoL potential:
End of life
option

% recovered

Energy
(J)

casting

Recycle

100.0

-1.3e+08

100.0

heat shield

Landfill

100.0

0.0

morter

Landfill

100.0

0.0

conductor

Landfill

100.0

0.0

insulation

Landfill

100.0

0.0

connecting hose

Landfill

100.0

0.0

hose conector

Landfill

100.0

0.0

other

Landfill

100.0

0.0

-1.3e+08

100

Component

Total

Summary

Notes:

space heater.prd

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 5 / 9
Wednesday, September 16,
2015

Eco Audit Report


Summary

CO2 Footprint Analysis

CO2 (kg/year)
Equivalent annual environmental burden (averaged over 3 year product life):

2.03e+04

Detailed breakdown of individual life phases


Summary

Material:
Recycled
content*
(%)

Part
mass
(kg)

Qty.

Total mass
processed**
(kg)

CO2
footprint
(kg)

Virgin (0%)

5.7

5.7

13

70.8

Virgin (0%)

0.4

0.4

2.1

11.2

Wrought iron

Virgin (0%)

0.13

0.13

0.3

1.6

conductor

Copper, C10200, wrought, soft


(oxygen-free h.c. copper)

Virgin (0%)

0.08

0.08

0.29

1.5

insulation

PE-LD (molding and extrusion) Virgin (0%)

0.08

0.08

0.24

1.3

Virgin (0%)

0.35

0.35

0.68

3.6

Virgin (0%)

0.09

0.09

0.32

1.7

Virgin (0%)

0.22

0.22

1.6

8.3

19

100

Component

casting
heat shield
morter

connecting hose
hose conector
other

Material
Carbon steel, SA216 (Type
WCC), cast, normalized &
tempered
Stainless steel, austenitic,
AISI 321, wrought

Natural rubber (unreinforced)


Brass, CuZn39Pb2, C37700,
wrought, soft (leaded (forging)
brass)
PC (high viscosity, molding
and extrusion)

Total
*Typical: Includes 'recycle fraction in current supply'
**Where applicable, includes material mass removed by secondary processes

space heater.prd

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 6 / 9
Wednesday, September 16,
2015

Manufacture:

Summary

Component

Process

% Removed

Amount processed

CO2
footprint
(kg)

Total

%
100

Summary

Transport:
Breakdown by transport stage
Stage name

Transport type

Distance
(m)

CO2 footprint
(kg)

land

32 tonne truck

6e+05

0.14

10.3

sea

Sea freight

1.5e+07

1.2

89.7

1.6e+07

1.3

100

CO2 footprint
(kg)

Total

Breakdown by components
Component

Mass
(kg)

casting

5.7

1.1

80.7

heat shield

0.4

0.076

5.7

morter

0.13

0.025

1.9

conductor

0.08

0.015

1.1

insulation

0.08

0.015

1.1

connecting hose

0.35

0.066

5.0

hose conector

0.09

0.017

1.3

other

0.22

0.042

3.1

Total

1.3

100

space heater.prd

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 7 / 9
Wednesday, September 16,
2015

Summary

Use:
Static mode
Energy input and output type
Country of use
Power rating
(W)

Mobile mode
Electric to thermal
United States
9.3e+03

Usage (hours per day)

24

Usage (days per year)

1.8e+02

Product life (years)

Fuel and mobility type


Country of use

United States

Product mass
(kg)

Distance
(m per day)

Diesel - heavy goods


vehicle

1e+05

Usage (days per year)

Product life (years)

Relative contribution of static and mobile modes


Mode

CO2 footprint
(kg)

Static

6.1e+04

100.0

Mobile

Total

6.1e+04

100

Breakdown of mobile mode by components


Component

CO2 footprint
(kg)

casting

heat shield

morter

conductor

insulation

connecting hose

hose conector

other

Total

space heater.prd

100

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 8 / 9
Wednesday, September 16,
2015

Summary

Disposal:
End of life
option

% recovered

CO2
footprint
(kg)

casting

Recycle

100.0

0.28

93.6

heat shield

Landfill

100.0

0.0056

1.9

morter

Landfill

100.0

0.0018

0.6

conductor

Landfill

100.0

0.0011

0.4

insulation

Landfill

100.0

0.0011

0.4

connecting hose

Landfill

100.0

0.0049

1.7

hose conector

Landfill

100.0

0.0013

0.4

other

Landfill

100.0

0.0031

1.0

0.3

100

Component

Total

EoL potential:
End of life
option

% recovered

CO2
footprint
(kg)

casting

Recycle

100.0

-9.6

100.0

heat shield

Landfill

100.0

0.0

morter

Landfill

100.0

0.0

conductor

Landfill

100.0

0.0

insulation

Landfill

100.0

0.0

connecting hose

Landfill

100.0

0.0

hose conector

Landfill

100.0

0.0

other

Landfill

100.0

Component

Total

0.0
100

Summary

Notes:

space heater.prd

0
-9.6

Report generated by
CES EduPack 2015 (C) Granta Design Ltd.

Page 9 / 9