The Importance Of Best Efficiency Point (BEP)

Understanding the factors involved in pump performance is key to optimizing the fluid-handling
systems in your operations.
ByEugene Vogel, Electrical Apparatus Service Association (EASA)
Have you become so focused on the efficiency of the motors around your plant that youre losing sight of the equipment those
motors are driving? In many applications, pumps included, the answer to the efficiency question is best addressed when the
complete system is studied.
Sooner or later, most maintenance professionals who work with pumps will encounter a pump curve and its key parameters, one
of which is Best Efficiency Point (BEP). The BEP graphically represents the point on a pump curve that yields the most efficient
operation. For electric motors, efficiency varies with load, with the best efficiency being at about 75% of load. With rotodynamic
pumps (which includes centrifugal and axial flow types), efficiency depends on three important pump curve parametershead,
flow (i.e., capacity or volume) and poweras expressed in this simple equation:

As the equation shows, power is inversely proportional to efficiency, which basically means pumps use less power when operating
more efficiently. But power is also directly proportional to flow X head (Q X H), both of which vary with demand in a rotodynamic
pump system. If the system restricts the discharge of the pump, as when a discharge throttle valve is closed, the flow decreases
and the head increases. Conversely, less restriction from the system means greater flow and less head. This relationship is
illustrated by a pump curve that is specific to each pump (see Fig. 1).

To understand BEP, it is essential to know that the flow through a rotodynamic pump varies from zero flow at dead head
(discharge valve closed) to maximum flow at run out condition (no discharge restriction). Pump efficiency, it turns out, is a
function of flow through the pump, although it is not strictly linear (see Fig. 2).

Effect of flow rate


To visualize how flow affects pump efficiency, imagine the flow of traffic on a highway, with efficiency measured as cars per
minute. Late at night with no cars on the road (and therefore no traffic), efficiency is zero. Early in the morning, traffic moves
quickly, but with few cars traveling, efficiency remains low. During rush hour traffic volume greatly increases, so bottlenecks form,
traffic slows to a crawl and efficiency plummets. Usually, there is a time just before rush hour with lots of fast-moving traffic when
the highway handles the most cars per minutei.e., its BEP.
The BEP for a pump is similar (see Fig. 3). With the discharge valve closed (dead head) and zero flow, efficiency is zero. As the
discharge valve opens (i.e., the discharge restriction is gradually reduced), flow and efficiency gradually increase, until the flow
through the pump becomes more turbulent. At that point, efficiency will start dropping and then continue to drop as the pump
approaches run out condition (zero). As with traffic flow on a busy highway, somewhere between dead head and run out
condition, there is a flow rate at which the efficiency is maximumi.e., the BEP.
Note that the BEP in Fig. 3 occurs at a flow rate of about 1600 unitswhich coincides with the maximum value on the efficiency curve.
That flow rate also intersects the pump curve at a point equal to head of about 220 units.

If the efficiency of the pump changes with flow rate, a logical question might be Why? As mentioned earlier, one reason is that
pump efficiency directly correlates with turbulence in the flowi.e., the greater the turbulence, the lower the efficiency. Thus, it makes
sense that the BEP is where turbulence is minimal.
Effect of impeller design
Impeller design is the most significant factor for determining the BEP of a pump because it dictates how efficiently power (brake
horsepower or BHP) is transmitted to the liquid being pumped (pumpage). A properly designed impeller optimizes flow while
minimizing turbulence.
Pumpage enters the impeller eye and accelerates as it travels radially outward toward the impeller discharge. As theliquid
discharges from the impeller, it merges with liquidalready in the impeller housing. If the impeller vanes are at just the right angle
relative to the flow rate, incoming pumpage will merge smoothly with the swirling pumpage in the housing, minimizing turbulence,
maximizing efficiency and yielding the BEP for that impeller.
Designers use a series of vectors to calculate impeller vane angle for a certain flow rate. As shown in Fig. 4,vector Vt represents
the speed of the vane tip (tangent andrelative to the impeller), and Vr represents the radial velocity of the pumpage flowing out of
the impeller. The discharge angle of the flow is Vm, the sum of vectors Vt and Vr, which should match the impeller vane angle at
the discharge. The length of vector Vr changes with flow rate, so greater flow through the pump means the pumpage must move
faster as it exits the impeller.

Note that the flow rate changes the discharge angle, but the impeller vane angle remains constant. The BEP is the flow rate where
the discharge angle matches the vane angle. Similar design factors apply to the impeller intake. Although impeller housing
characteristics also play a role, the impeller design is the primary factor that determines the flow rate at which the BEP occurs.
Points to remember
The most important thing to remember from this discussion is that any modification of the impeller will change the BEP of the
pump. Trimming the outside diameter (OD) of an impeller, replacing an impeller with one of different diameter or number of vanes
or changing the rotating speed of the impeller will alter the BEP for the pump.
Before modifying an impeller in any way, make sure that you determine how the change will impact the pump curve, the efficiency
curve and the BEP. UM
Eugene Vogel is a Pump and Vibration Specialist with the Electrical Apparatus Service Association, Inc. (EASA), in St. Louis, MO. EASA is
an international trade association of more than 1900 firms in 59 countries that sell and service electrical, electronic and mechanical
apparatus. Telephone: 314-993-2220; email: easainfo@easa.com; Web: www.easa.com.

You may also like:


Problem Solvers
Gaining An Edge With The Right Hydraulic Fluids
Honeywell Introduces Cold Conditions Fire Retardant Apparel

EXAIR Reversible Drum Vacs are CE Compliant


Swift-JB Intl. Offers High Pressure Filter Assemblies
Keeping Motors And Gearboxes In Tip-Top Shape
[ what's this ]

Follow Us

About Maintenance Technology


View all posts by Maintenance Technology

Sage Advice: Understanding RCM

0 Comments

Efficient Gadgets
1

Maintenance Technology

Recommend 1

Share

Login

Sort by Best

Start the discussion

Be the first to comment.

WHAT'S THIS?

ALSO ON MAINTENANCE TECHNOLOGY

Making Sense Of Plant Maintenance

Enhanced Cooling Tower Maintenance Saves


Water

1 comment a year ago

Sap Pm Its very useful and interesting.This is a

good chance to take decisssion to motiviate


before going to PM http://sappmtraining.com/

1 comment a year ago

Mikito Ohara What is the main advantage of

using that bulky cooling towers from the modern


technology cooling towers? Cooling

Are You Ready? Preparing For Reliability


Improvement

Building And Using Effective Visual


Management Boards

1 comment 2 months ago

1 comment 8 months ago

Jennie Great article, Wayne. It is so important to

ProjectCanvas Thank you Rick for the

update maintenance practices so your company


can work efficiently and effectively!

comprehensive article. Project Canvas


(www.projectcanvas.dk) might be of interest

Subscribe

Add Disqus to your site

Privacy

Search...

Back to top
Quick Links
Advertise
Contact Us
Events
Products
Subscribe
Videos
Webinars
White Papers

Recent Posts
Are Your Marketing Dollars Paying Off?
GP:50 Introduces USB Digital Output Pressure Transducers
Synchrono Releases New Version of Manufacturing Intelligence Software
Swift-JB Intl. Offers High Pressure Filter Assemblies
CBS ArcSafe Introduces RSA-56C Remote Switch Actuator

Latest Issue

Tweets
Swift-JB Intl. Offers High Pressure Filter Assemblies http://t.co/FsImRCmbSD 2 days ago

Production operations begin at new ABB robot plant in Auburn Hills, MI. Site to serve booming North American
Market. http://t.co/fWb9JQzxMs 1 week ago
Follow mtmagazine on Twitter

2015 Maintenance Technology. All Rights Reserved.

Das könnte Ihnen auch gefallen