List of Physical Testing Equipment

S.No.
1.

Equipment
Blain Apparatus

Detail
Variable Flow Type

Make Com.
AMIL

Quantity
3

1a.

Permeability cell with


preformatted metal
Disk
Filter Paper Disk
Mercury

For determination of
Specific surface

AMIL

Whatsman No. 40
For calibration of
Blaine Apparatus
Accuracy up to 0.1
second

Self
GLAXO

Sufficient
One Kg

Self

For Standardization of
Blain apparatus
Accuracy up to 0.0001
gm.
For determination of
Setting time

NCCBM

6 Vails

Mac

AMIL

Double pan with


accuracy 50 gm. Can
weight up to
Double pan with
accuracy 0.01gm.

NSW,Varanasi /
Self

NSW,Varanasi /
Self

400 gm capacity

AMIL
AMIL

12
2

10,100,150ml
700 x 700 x 10 mm
For Soundness test

BOROSIL
Self
AMIL

2-2
1
12

Water should boil in 25


min.
0-300 mm with scale
division of 0.5mm
For measuring the
Expansion
For calibration

Ambassador/self

Gesma /self

AMIL

AMIL

1b.
1c.
1d.

1e.
2.
3

4.

5.

6.

7.

8.

Stop Watch with


starting stop
mechanism
Standard Cement
Electrical Single pan
Chemical Balance
Vicat apparatus with
Plunger and Initial
Final Setting time
needles
Physical Balance with
Weights from 50 gm.
to 3 kg.
Physical Balance with
Weights from 10 mg.
to 100 mg.
*Setting Time Moulds,
*Gauging Trowels,
*Measuring Cylinder,
*Gauging plate ,
* Le-Chatelier moulds
along with weight and
cover glasses ,
* Water Bath with
Thermostatic control
* Measuring Scales
* Length Comparator
* Standard Bar

* Thermometer
* Auto Clave Bar
Moulds
9.

CST Machine

10.

* Vibrating Machine
with cube mould fitting
assembly
* Cube moulds
* Digital Tachometer
* Standard send
Grade I
Grade II
Grade III

11.

Proving Ring with all


accessories

12.

Humidity Chamber

13.

Hygrometer

14.

Aeration Chamber

15.
16.

Laboratory
Thermometer
Laboratory Ball Mill

17.

Air Conditioner (AC)

0 to 250o c with scale


division of 0.1oc
Size 25x 25 x 282 mm

2
Self/Zeal
AMIL

6 Nos
Double

Motorized cum Hand


operated duly
calibrated
12000 rpm

AMIL

AMIL

Size 70.6 x 70.6


For Calibration of
vibrating Machine
Tamin Brand From
Tamilnadu
-Do-Do-

AMIL

52

Countronics

Duly calibrated for


calibration of CST
Machine
Self fabricated with
humidity maintaining
arrangements.
For finding out the
humidity range 0 to
100 %
Self fabricated with
two partition all side
walls mosquito proof
wire gauge for keeping
the sample for aeration
.
0 to 500c

Perpetual
Instrument
(INDIA)
Self

JTIA , JAPAN

Self

Zeal / Self

Motorized with
capacity approx 6 kg
Clinker locally grinding
media
For Maintaining Room
Temp.

LAWRENCE &
MAYO

Self

1 Bag
per
grade

18.

Room Heater

19.

Mixing Tray

20.

Curing Tank

For Maintaining Room


Temp.
With 24 Partition for
keeping hourly sample
& making composite
sample.

Self

Self

Self