Many states require UST owners and operators to obtain an operating permit.
Contact your state regulatory authority for specific permit requirements.
than 42,000 gal. The level of SPCC Plan detail and whether the Plan needs to be
certified by a licensed professional engineer (PE) are determined by the total
aggregate oil storage and the size of the largest tank at a facility.
When replacing or installing new ASTs, consider choosing a tank size that will
keep your facility below the following SPCC thresholds:
Facilities with aggregate aboveground oil storage capacity of 1,320 gal or
less and completely buried oil storage capacity of 42,000 gal or less are
not subject to SPCC rules.
Facilities with aggregate aboveground oil storage capacity of 10,000 gal or
less and that have not had significant oil spills in the past 3 years are
considered qualified facilities and may self-certify their SPCC Plan and
amendments rather than use a PE.
Qualified facilities with no individual aboveground oil storage container
with a capacity greater than 5,000 gal and no significant oil spill over the
past 3 years are considered Tier 1 qualified facilities and have the option
to complete a self-certified SPCC Plan template instead of a full SPCC Plan.
Federal UST rules allow the use of manual tank gauging as the sole leak detection method for USTs 1,000 gal or smaller. Consider using a smaller tank to store
products such as used oil to avoid having to employ more costly and complex
leak detection methods.
Sections 311 and 312 of the Emergency Planning and Community Right-to-Know
Act (EPCRA) require facilities storing hazardous chemicals above certain thresholds to submit safety data sheets (SDSs) or a list of SDS chemicals, as well as an
annual inventory of those chemicals to state and local emergency response officials. The storage threshold that triggers reporting for most hazardous chemicals
is 10,000 pounds. The threshold is lower for extremely hazardous substances and
higher for gasoline and diesel fuel stored in USTs at retail gas stations. Before
adding or replacing tanks at your facility, determine the EPCRA reporting threshold of the chemical or product you plan to store and convert that number to
gallons. If facility or process requirements allow, consider using a smaller tank
to keep your maximum inventory below the applicable storage threshold. For
example, storing heating fuel in a tank with a capacity less than 1,300 gal,
provided there is no other heating fuel storage at the site, will enable a facility
to avoid EPCRA chemical inventory reporting obligations for that product.