Sie sind auf Seite 1von 8

Release Notes for Altium Designer Version 15.

0
Modified by Nikolay Ponomarenko on 16-Mar-2015

Key feature highlights


High Speed Design with xSignals
Solder Mask Expansion Enhancements
Accurate Route Length Calculation
Polygon Enhancements
OLE Object Support in PCB Documents
Support for Rectangular Pad Holes
Separate 2D & 3D View Orientations
IPC-2581 Support
Gerber X2 Support
IDX Support
Exporting to IDF in Unicode Format
True Variants Enhancements
Output Job Editor Enhancements
Upgraded Duplicate UID Correction
System and Performance Enhancements
Vault Connection Enhancements
Ability to Control Parameter Visibility for Vault Components
Parameter List Templates
Parameter-based Name Templates
Vivado toolchain improvements
Intuitive Import and Export

Version 15.0.15
Build: 41991 Date:16 March 2015
4720

Releasing a managed project to Altium Vault for a second time no longer reports a
Release.Log error.

5205

Resolved issue where changes made to an Output Job from the Configuration Manager are not
saved (BC:5258).

4999 Intermediate files no longer be removed during synthesis.


5111 Improved stability of Allegro importer when working with large designs.
5257

Resolved issue where running an FSO on pins from multiple parts results in none being
selected.

5258

Resolved issue when deleting multiple sub parts of a component in the schematic library
editor, the selected components aren't always the ones that are deleted (BC:4768).

5260 Special strings with parameters containing "-" or "." symbols are now processed properly.

5262 Re-annotate works properly now for components initially placed on the PCB.
5264 A proper DuplicateID warning is shown for cases when repeat sheet symbols are used.
5410 Resolved an issue with saving menu customizations between sessions (BC:4957, BC:5299).

Version 15.0.14
Build: 40656 Date:19 January 2015
4317 Rotation of components is now correctly exported to dwf/dxf formats (BC:4977)
4892 Fixed generation of pdf file via outputjobs when parametric file name is used
4899 Fixed issue of Japanese translation that prevents PCB document to be loaded

Version 15.0.13
Build: 40581 Date:16 January 2015
4634 Length calculation is now taking into account through-hole pins height
4367 Fixed Protel PCB 2.8 export
4401 "Create xSignals from connected net" command now has dedicated dialog
4601 Issues with layer disappearance while working with rigid -flex layer stack
4656 Components with @ in UniqueID are now properly included into Pick&Place files
4663

Gerber generation of embedded board referencing non existent pcb document do not crashes
anymore

4738 Altium Designer do not hangs anymore during Spectra files import (BC:5054, BC:5047)
4747 Exception while working with split planes was fixed (BC:5059)
4825 Task with DrillDrawing printed to pdf do not prevent release to Vault anymore
4207

The option "Always repour polygons on modification" has been added to the PCB Editor General page of the Preferences dialog (BC:5010).

4394

xSignal length calculation includes path inside of the component (as shortest path between
pads)

4650 Fixed work of copy/paste between components in schlib


4682

Visibility of Comment field on placement from DBLib restored to old behaviour and is driven
by symbol setting (BC:4994)

4745 Chinese (Traditional) translation was updated


4793 Resolved problem with pdf file opening using FoxirReader
4812 Altium Designer detects Component Clearances correctly
4833 Fixed error with downloading released data via web browser
4836 Device Support Report no longer crashes
4845 IPC2581 output can now be generated via PCBReleaseView

Version 15.0.8

Build: 38726 Date:26 December 2014


4206

IPC Footprint Wizard - PSON Solder Mask Expansion default setting changed back to
"Expansion value from rules"

4261 Altium Designer no longer requests that Adobe Reader be installed on the system.
4396 Issues with opening older Protel/Altium designs have been resolved.
4417

If an Outjob PDF included =VariantName in the filename it could cause an exception, this no
longer occurs.

4438 Acrobat Reader XI is now properly recognized by Altium Designer


4443 Fixed error with Pin Swapping affecting xSignals
4444 Import MCAD IDX menu entry moved to the File Import menu.
4446 Altium Designer no longer hangs while generating Board Stack report (BC:5002)
4447 Excel processes no longer remain running after Excel-based report generation.
4449 Redundant dialog about shelved polygon removed from STEP exporter
4452 Proper net name is being shown for shelved polygons in Polygon Manager
4458 Ctrl+R (Rubber Stamp) now works correctly in the Schematic editors.
4478 "Invalid argument to date encode" error during release to Vault is fixed
4479 Fixed naming of features in exported step files
4487 Fixed CADSTAR schematic importer
4493 Fixed crash in cmplib while openning file with models requiring update
4497

Certain editing scenarios could result in an exception in the schematic editor (error details
included "read of address 80808088"), this no longer occurs.

4504

New polygons were immediately shelved in some installations of Altium Designer, this no
longer occurs.

4506 Fixed issue with sch print via PDF printer in outputjob (BC:4947)
4537 Fixed disappearing wire dragging in sch
4539

It was not possible to have CmpLib folders of the same name, with a different path - this has
been resolved.

4560 xSignal related length matching DRC are now shown in report and violations panel (BC:4960)
4586 Fixed Orcad importer
4590

BOM generation do not hangs anymore, when ActiveBOM is used as source with Variant
switch

Version 15.0.7
Build: 36915 Date:17 November 2014
1015 Support for high DPI screens using oversized fonts has been reviewed and improved.
1335

PCB NC drill layer pair reports now correctly report layer spans for blind/buried via holes,
when layers are shuffled out of default order.

1381 Export to AutoCAD now correctly includes thru-hole pad geometries and holes.

1382

After certain editing sequences the PCB editor would incorrectly switch to masking the display,
this no longer occurs.

1408 IDF export now includes an option to export in Unicode format.


1615

Changing PCB layer names could result in layer-related lists populating incorrectly and certain
outputs not generating correctly, this has been fixed.

2613 A Vault Content Cart can now target regular folders.


2816

It is now possible to define a CmpLib Component Naming scheme using a template with
values from any parameter, for example CMP-[Value]-[PackageReference]-{0001}.

The CmpLib editor now supports the addition of new parameters via customizable parameter
2817 list templates. Click the Required Models/Parameters Add button to access the templates
(samples are stored in the \Templates folder).
2855

Duplicate UniqueIDs are detected by the Schematic compiler and detailed in the Messages
panel. Existing duplicate UIDs are also automatically resolved during document loading.

2910 Release Notes column is now available when using Vault-based libraries in the Libraries panel.
3006

The Component Cuts Wire mode now functions correctly when the Always Drag option is
enabled.

OutputJob Editor enhanced by the addition of: mouse wheel scrolling & scroll bars when not
3008 all Jobs/Containers are visible, drag and drop to change Job order, multi-Job Enable/Disable
right-click commands & shortcuts (select the container first).
3026

Import and Export options are now directly accessible via the Files menu. Save As commands
are now used exclusively for Altium file formats. (BC:1812, BC:2731 partial)

3033

Gerber X2 is now available as an output format. It supports output generation via the PCB
editor Fabrication Outputs menu, or via an OutputJob.

IPC-2581B is now available as an output format. Install the extension and generate output via
3035 the PCB editor Fabrication Outputs menu, or via an OutputJob. Download a free viewer from
http://www.ipc2581.com/index.php/ipc-2581-files
3081

The Vaults panel now supports changing the column visibility and order. These changes,
along with panel-section resize actions are retained between sessions.

3143 Timeout errors after releasing project documents to a Vault have been fixed.
3188 OutputJobs now support using a slash character in the Output Container Name.
It is now possible to pre-configure the display state of Vault component parameters, via the
3189 Vault Folder Properties dialog (Type = altium-component-library) and the Vault Library dialog
(add a Vault as a Library).
3205

Switching from the logical to the physical tab of a schematic no longer leaves artifacts on the
screen.

3225

Schematic dragging has been further developed to improve wire/bus bending and reduce the
likelihood of a netlist change.

3227

Schematic dragging has been further developed to improve object handling and the quality of
the result, and reduce the likelihood of a netlist change.

3232

Polygon vertex deletion using Ctrl+Hover+Click is now working correctly. Hold the left mouse
button down as you click, until the vertex disappears.

3251 Releasing projects to the vault with file-locking being enabled works correctly now

3272

The schematic library editor panel now supports standard copy and paste shortcuts, Ctrl+C
and Ctrl+V.

3293

BOM filters no longer mix up the parameters. Note that for an existing BOM the filters must be
cleared, the BOM saved, closed and re-opened, and the filters re-defined.

3338

Multi-net routing no longer creates a clearance violation at corners when the Converge
shortcut (C) is pressed.

3341

When a PDF is generated from a schematic that includes a hyperlink, clicking the hyperlink
now opens the target web page correctly.

3357 Teardrop removal speed has been improved.


3381 Second click to select an individual segment in a schematic wire now works correctly.
3412

The issue with not being able to close documents having "=" character in their name has
been resolved

3419

When the Interactive Router is in push mode, a via on the pushing net can push other-net
objects, including vias.

3423 A specific Verilog HDL project would cause an AV on compile, this no longer occurs.
3425

Update from Libraries now correctly preserves existing location and orientation of parameter
strings.

3437

2D and 3D PCB view orientations are now completely separate, each retains the previous
orientation and zoom when switching between the views.

Pin-pairs have been added to the PCB editor, delivering the ability to define the path and
3441 constraints for a signal to travel between a source and destination, through termination
components and y-splits.
3442 The import of complex arc shapes from AutoCAD has been improved.
3443

The PCB Editor now supports embedding OLE objects, such as Word or Excel documents, into
a PCB document (Place Object from File).

3456

Xilinx Vivado toolchain is now correctly detected, and can also be added manually in the FPGA
- Place and Route preference settings.

3457 Split plane editing could occasionally cause an exception, this no longer occurs.
When a wire is placed perpendicular to multiple schematic pins and then dragged, a wire
3459 segment is automatically added between every pin and the wire being dragged. This fix
restores previous schematic editing behavior.
3477

Schematic library editor, the Parameter Manager now supports editing parameters across
multiple selected components.

3492

A warning is displayed when you attempt to complete an invalid blanket (has intersecting
edges) in the schematic editor.

3495

PCB component fanout now functions correctly when there is an unpoured polygon under the
component.

3497 Click and drag to move a group of selected objects now be functions correctly.
3498 An exception that occurred during import of specific DxDesigner projects has been resolved.
3514 PCB Step model import has been enhanced with better support for curved shapes.
3521 Fileless editing of an external SIM model no longer generates an AV.
3528 AVS 1.1 is now supported by Altium Designer 14.3.

3529

Component pads placed on a signal layer other than top or bottom could not be edited in
certain layer-stack configurations, this no longer occurs.

3530 Top and Bottom Solder Mask layers are now included in the PCB Filter panel's Layer list.
3546 The IPC Footprint Wizard now previews 2-pin and 3-pin DFN component correctly.
3551 Schematic auto-junctions now size correctly regardless of the wire width.
3556

Component primitives placed on mechanical layer 17 or higher now have their layer displayed
correctly in the Components mode of the PCB Panel.

3560

It is now possible to connect to an SVN repository with a user name containing the @
character.

3561 The correct Lifecycle and Naming Schema is now being loaded during CmpLib file-less editing.
3567 Model selection drop-downs in the CmpLib editor now display the Lifecycle state in color.
3568 The Vaults panel now shows the Note data from the correct Lifecycle state.
3576 PDF generated by running OutputJob can be opened directly from OutputJob document
3577 Simulation model pin mapping now works correctly in the CmpLib editor.
3585

Pin swapping was not correctly generating an ECO after performing PCB pin swapping, this
has been resolved.

3592

The path tracing routines used for creating a polygon from selected primitives have been
improved, to better handle small objects and multiple paths.

3598 From-To panel now shows length taking via heights into account
3611

The schematic Place Wire command now correctly retains the corner mode used in the
previous wire placement.

3626 Vault-defined part choice currencies are now used in Altium Designer supplier dialogues
3633 Updating Altium Designer from an NIS no longer requires a current Portal connection.
3634 "Access denied" error when installing an update from NIS has been resolved
3640 Support for rectangular-shaped pad holes has been added
3664

PCB exception while re-building a net to an arc center point in a specific design no longer
occurs.

3681 Plane connects (thermal reliefs) are now shown correctly when board is flipped
3689 Exception no longer occurs when choosing PCB font style in VariantManager (BC:4664)
3692

Pads with rotated square holes no longer show copper still being present after running the
Remove Unused Pad Shape command.

3695 GOST specific documents can now be generated in BOM Report outputs
3707 "No model link found for component" error no longer occurs while editing old cmplib files
3708 Clicking on a supplier part number in the Vaults panel no longer causes an exception.
3721 Occasional exceptions during a print preview no longer occur.
3722

Under certain conditions changes made in the Variant Management dialog could cause an
exception, this no longer occurs.

3729

The Variant Management dialog now immediately reflects changes to components, such as
clearing or choosing an Alternate Part, improving usability.

3732

The Edit action is now available when right-clicking in the Search results panel in the
VaultExplorer

3736 Fixed error while releasing Vault revisions with extra long file and path names
3737

Changes to Comment and Description are no longer lost during component release from the
CmpLib editor

3739 A Length column has been added to the Primitives table in the Nets view of the PCB panel
3755 Scope section of the Teardrops dialog was modified to distinguish TH and SMD pads
3757

Duplicate Port UIDs no longer cause Port names to be changed when generating a PDF from
the schematic.

3774

Under certain conditions, schematic compile masks did not exclude components or net
objects underneath them, this has been resolved.

3778

On a schematic with a lot of wiring, placing a wire with the Break Wires at Autojunction option
enabled was very slow, this has been optimized.

3779 Improved performance of selection and zooming in Schematic in comparison with 14.3
3785

Under certain conditions it was possible to get the PCB Layer Stack Manager graphical
representation out of sync with the tabular layer detail region, this has been resolved.

3787

The "Print as a single job" option in Output Job File documents now properly combines the
separate documents to a single print output

PCB re-annotation on a variant design with not-fitted parts could result in the varied parts
3789 becoming out of sync, this no longer occurs. Note: PCB re-annotation on a design that uses
alternate parts with different footprints is not yet supported.
3792 STEP models from Inventor 2014 are now loaded without errors
3800

Variant PCB drawing options have been updated to make it easier to understand how Not
Fitted components are displayed.

3809

It is now possible to specify different values for solder mask expansions for top and bottom
layers

3834 Empty surface constructs are now suppressed in ODB++ fabrication output.
3835

The IPC footprint wizard now correctly supports defining PLCC packages with different D and E
pin counts, allowing packages with any even number of pins to be created.

3836

Dragging multiple schematic wire ends could occasionally result in one wire being shorter
than the rest, this no longer occurs.

3841

Reset All command added to the Variant Manager, use this to restore all parameters to
alternate or base component values.

3844

The issue resulting in "I/O error 103" error message when some of the project files are
read-only has been resolved

3845

The speed of updating from libraries or a database has been improved for designs that
include variants using alternate parts.

3849

In certain circumstances a component would still be shown as varied after resetting


parameter variations, this has been resolved.

3857

Polygon management was improved in comparison with 14.3 (restored shelving, modified
concept)

3875 The Vaults panel right-click menus now display correctly when Display scaling is being used.

3876

Elements of the Vaults panel were being compressed when Display scaling is being used, this
no longer occurs.

3888 Crash reports can now be send from behind a proxy


3889 Simulation Waveform viewer print preview issue has been fixed.
3900 Class generation settings are now stored for device sheets (BC:3840)
3903

The time to open the PCB Classes dialog has been substantially reduced, particularly on
designs with a large number of classes.

3972

ODB++ output did not generate drill data for drill holes included in a panel, when none of the
embedded boards had drill holes, this has been resolved.

3984

Drawing of Schematic Blanket directives has been further optimized to get them to draw
quickly and also correctly display the fill color.

4005

Variant designs that include alternate parts with different footprints can now be re-annotated
in the PCB editor.

4016 PCB DRC now supports stacked alternate parts in a variant-based design.
4049

Signal length column was added to Nets panel (this length is being calculated using more
precise xSignal engine)

4062 All extensions within a group can now be installed in a single action.
4069

Some PCB dialogs were ignoring the board units and always displaying in mils, this no longer
occurs.

4076 Modified Polygon rule support check for shelved polygons


4083

During import of a P-CAD PCB file the layer types are now correctly detected and assigned for
all possible layer configurations.

4092

The DRC Violations Display page of the Preferences dialog now displays the complete list of
Display Style entries when Windows display scaling is being used.

4098

An AV could occur while placing a pin in a schematic library and pressing Esc to quit the
command, this no longer happens.

4111

With a specific combination of preferences, placing a component from the schematic libraries
panel could cause Altium Designer to crash, this no longer occurs.

4121

After configuring components for pin swapping, it is no longer necessary for the designer to
manually recompile the design to make those swap configurations available.

4133 Changes made in the FPGA Signal Manager are now correctly added to the constraint file.
4135

Silk to Solder Mask design rule now correctly detects both silk to solder mask or silk to copper
rule check configurations.

4215

When a polygon is shelved, connections created by the polygon are maintained internally so
the connection lines will not be displayed.

4351 NIOS II CPU does not generates with Altera Quartus version 13.0 or later

Source URL: http://techdocs.altium.com/display/ADOH/Release+Notes+for+Altium+Designer+Version+15.0