Sie sind auf Seite 1von 5

Ancillary

Texa FAN

Fan & Filter Ventilating Units

Index
Catalogue Information
Leaflet

Web Links
Texa FAN Information Page
Ask a question / Send us an enquiry
Information about B&R
Local Sales Team Phone Numbers

B&R Enclosures Pty Ltd, PO Box 1151, Browns Plains BC, QLD 4118
Ph 07 3714 1000 Fax 07 3714 1081

Texa FAN
Fan & Filter Ventilating Units

brenclosures.com.au/fan.htm

Texa FAN Features


Reversible air ow direction
Click-in tting with no screws
required (all enclosures but Econo
EC range which requires the
supplied screw kit)
30,000 hours life expectancy
Optional temperature control
thermostat
Approvals - CE, UL94 V0
Materials - ABS plastic grill
Protection rating - IP54

The Texa FAN and FIL ranges are

reversible so air can be pumped into

fans and lters with air ow capacities

the enclosure as normal or pulled out

from 57 to 580 m3/h. Fan units are

of the enclosure should the need arise.

Inclusions
All xings required for assembly.

FAN Selection Guide - DC


Catalogue No

Air Flow
Rate (m3/h)

Power Supply
(V/Ph/Hz)

TX-FAN12UN0A

60

24 V DC

Dimensions (mm)
Height

Width

Depth

Matching Filter

150

150

67

TX-FIL12XN0A

TX-FAN12VN0A

60

48 V DC

150

150

67

TX-FIL12XN0A

TX-FAN23UN0A

120

24 V DC

250

250

102

TX-FIL25XN0A

TX-FAN23VN0A

120

48 V DC

250

250

102

TX-FIL25XN0A

TX-FAN25UN0A

230

24 V DC

250

250

114

TX-FIL25XN0A

TX-FAN25VN0A

230

48 V DC

250

250

114

TX-FIL25XN0A

FAN Selection Guide - 115V


Catalogue No

Air Flow
Rate (m3/h)

Power Supply
(V/Ph/Hz)

TX-FAN12CN0A

57/61

TX-FAN23CN0A

115/125

TX-FAN25CN0A
TX-FAN28CN0A*
TX-FAN35CN0A
* Available on request

108 Ancillary Items

Dimensions (mm)
Height

Width

Depth

Matching Filter

115/1/50-60

150

115/1/50-60

250

150

67

TX-FIL12XN0A

250

102

TX-FIL25XN0A

230/262

115/1/50-60

400/440

115/1/50-60

250

250

114

TX-FIL25XN0A

250

250

98

TX-FIL35XN0A

520/580

115/1/50-60

325

325

153

TX-FIL35XN0A

FAN Selection Guide - 240V to 440V


Air Flow
Rate (m3/h)

Power Supply
(V/Ph/Hz)

TX-FAN12BN0A

57/61

230/1/50-60

TX-FAN23BN0A

115/125

230/1/50-60

TX-FAN25BN0A

230/262

230/1/50-60

TX-FAN28BN0A*

400/440

230/1/50-60

TX-FAN28LN0A*

400/440

TX-FAN35BN0A

520/580

TX-FAN35LN0A

520/580

Dimensions (mm)
Height

Width

Depth

Matching Filter

150

150

67

TX-FIL12XN0A

250

250

102

TX-FIL25XN0A

250

250

114

TX-FIL25XN0A

250

250

98

TX-FIL35XN0A

400/2/50-60

250

250

98

TX-FIL35XN0A

230/1/50-60

325

325

153

TX-FIL35XN0A

400/2/50-60

325

325

153

TX-FIL35XN0A

Introduction

Catalogue No

General Purpose

* Available on request

FIL Selection Guide - Filters


Dimensions (mm)

Power Supply
(V/Ph/Hz)

Height

Width

Depth

TX-FIL12XN0A

150

150

24

TX-FIL25XN0A

250

250

26

TX-FIL35XN0A

325

325

28

Special Purpose

Catalogue No

Air Flow
Rate (m3/h)

25 20 15

Multiple Application

Quick Selection Guide


T (C)

10
5

2000

800

Datacoms

P (W)

1000

600
500
400
300

Ancillary Items

200

100

5 6 7 8 10

20

30 40 50 60 80 100

200

300 400 500 600 800

Q (m3/h)
FAN 12
FAN + FIL
FAN free ow

FAN12
FAN
23
FAN23

Enclosure Selection

FAN 25
FAN25

FAN 35
FAN28
FAN free flow
FAN+FIL

FAN35
The
air flows shown in the graph refer to standard filters.

P = Heating power to be dissipated (W)


T = Temperature difference
(C or K)
Q = Air Flow Rate required
(m3/h)

Example:
Dissipated power
Temperature difference
Necessary air flow rate

500 W
10 K
3
160 m /h

Unit chosen
FAN25

The air ows shown in the graph refer to standard lters.

For more information visit www.brenclosures.com.au/fan.htm

B&R Enclosures Catalogue 2009 109

TEXA FAN Ventilating Units


The Texa FAN and FIL ranges are fans and lters with
air ow capacities from 57 to 580 m3/h. Fan units are
reversible so air can be pumped into the enclosure as
normal or pulled out of the enclosure should the need
arise.
A wide range of owrates
The range of air owrates that FAN ventilating units can produce
is from 57m3/h to 580m3/h. For larger ows we recommend a DLK
ventilating tower, but this ow range will cover the vast majority of
applications.
Quick & easy to assemble
A simple square cut needs to be made into the enclosure panel, and
the FAN unit is tted with a simple click-in system which requires
no screws. Compared to traditional systems this can save 20-30
minutes in installation time alone! The click-in system is suitable for
panel thicknesses of between 1.2 and 2.4mm, making it suitable for
almost all of the B&R range. If the panel falls outside this range, a kit
is included in the pack for a more traditional installation method.
The standard direction of air ow is from the outside to the inside of
the enclosure (supply ow) for all FAN units. If required the user can
reverse the direction of ow by simply removing and remounting the
fan in the opposite direction.
Reliability & minimal maintenance
The FAN units have an extremely high volumetric efciency, and
have an expected life of 30,000 working hours at an ambient
temperature of 55C. They are all designed to ensure quick and safe
electrical connect via a terminal board.
Maintenance is quick and easy, with ready access to lter cloths,
and options of washable lter cloths available.
Protection
The standard cloth lter is an EU4 type which has a ltering
efciency equivalent to 91% and an IP44 rating. It features a
progressive ltering surface made from synthetic bres. If a higher
rating is required an EU5 lter cloth will allow an IP54 protection
rating, and improves the ltering efciency to 97%. This is available
as an optional extra.

s
tail
e
d
for
e
c
of

R
u
al B& ures.com.a
c
o
l
r
u
o
nc l o s
Contact y
w.bre
ww

TECHNICAL INFORMATION
FAN range ventilating units are available for owrates of between 55
and 550m3/h. They are also available suitable for a wide range of power
supplies. The table below gives information on the range available, as
well as overall dimensions:
Air Flow Rate
(m3/h)

Power Supply V/
ph/Hz

Height

Dimensions (mm)
Width

Depth

150

150

24

TX-FIL12XN0A

250

250

26

TX-FIL25XN0A

325

325

28

TX-FIL35XN0A

57/61

230/1/50-60

150

150

67

TX-FAN12BN0A

57/61

115/1/50-60

150

150

67

TX-FAN12CN0A

60

24VDC

150

150

67

TX-FAN12UN0A

60

48VDC

150

150

67

TX-FAN12VN0A

115/125

230/1/50-60

250

250

102

TX-FAN23BN0A

115/125

115/1/50-60

250

250

102

TX-FAN23CN0A

120

24VDC

250

250

102

TX-FAN23UN0A

120

48VDC

250

250

102

TX-FAN23VN0A

230/262

230/1/50-60

250

250

114

TX-FAN25BN0A

230/262

115/1/50-60

250

250

114

TX-FAN25CN0A

230

24VDC

250

250

114

TX-FAN25UN0A

230

48VDC

250

250

114

TX-FAN25VN0A

400/440

230/1/50-60

250

250

98

TX-FAN28BN0A

Catalogue No

400/440

115/1/50-60

250

250

98

TX-FAN28CN0A

400/440

400/3/50-60

250

250

98

TX-FAN28LN0A

520/580

230/1/50-60

325

325

153

TX-FAN35BN0A

520/580

115/1/50-60

325

325

153

TX-FAN35CN0A

Queensland (Brisbane)

520/580

400/3/50-60

325

325

153

TX-FAN35LN0A

Ph 07 3714 1000

SALES OFFICES

Queensland (Townsville)
Ph 07 4775 6255

New South Wales (Sydney)


Ph 02 9687 0077

New South Wales (Newcastle)


Ph 02 4961 4433

Victoria (Melbourne)
Ph 03 8588 8400

South Australia (Adelaide)


Ph 08 8243 1166

Western Australia (Perth)


Ph 08 9248 9744

Tasmania (Launceston)
Ph 03 6331 5545

Northern Territory (Darwin)

ACCESSORIES GUIDE

FAN12

Ph 08 8947 0870

Cloth Filters EU4

Cloth Filters EU5

Cleanable Metal
Filters

Thermostat

FAN23

FAN25

FAN28

FAN35

www.brenclosures.com.au

Das könnte Ihnen auch gefallen