Beruflich Dokumente
Kultur Dokumente
FST4000 Series
DISPLACER TYPE LEVEL TRANSMITTER
GENERAL
FST4000 is a torque tube displacement type level indicating transmitter with intelligent data processing function. Through 18 years of
field proven experiences accumulated by the existing model FST3000, FST4000 has intensified its reliability by adding such features
as SIL2 compatible functional safety, ATEX flameproof and field bus
communication of FOUNDATION Fieldbus .
Varieties of materials and wide range of pressure ratings are available to meet various applications such as high pressure and temperature boilers as well as low temperature down to minus 196 of
liquefied gases.
STANDARD SPECIFICATION
1Detection method
2Measuring range
3Liquid density
1Level measurement
2Interface measurement
3Density measurement
8Ambient temperature
9Ambient humidity
10Available material
1Torque tube
ATEX
SIL2
HART, FOUNDATION Fieldbus
Communication
HART
FOUNDATION Fieldbus
Supply voltage
9 to 32 VDC 1
Base Current
18 mA DC or less
Input and output signals
conform to IEC61158-2
Communication protocol
FOUNDATION Fieldbus H1
H1 Profile Class
31PS, 32L
H1 Device class
Link Master
Function block
1-RB2, 1-AI, 1-TB
1 When a safety barrier is used in intrinsically safe circuit, the
supply voltage is 9 to 24 VDC. FISCO explosionproof 9 to
17.5 VDC
13Accuracy
0.5 %F.S (Based on mass
conversion correction at factory
calibration)
14Protection class
IP67, JIS C0920 equivalent to
IEC60529
15Explosionproof classification
1Flameproof
TIIS Exd II CT6 (under application)
ATEX & IECEx Exd II CT6,
KOSHA, NEPSI
2Intrinsically safe
TIIS Ex ia II CT6 (under application)
ATEX & IECEx Ex ia II CT6,
KOSHA, NEPSI
16Cable entry
G1/2, 1/2NPT, M20 x P1.5
17Painting
Transmitter Munsell 7.5BG4/1.5
Chamber silver
No painting on stainless steel
components
18Related standards referred ATEX (IEC60079-0, -1, -11)
EMC (IEC61000-4-2 to-4-6,
IEC61010-1, IEC61326-2-1,
EN5501), TIIS, PED
19Functional safety
SIL2 compatible with IEC61508
20RoHS Directive
Complied with
21Product mass
Pressure rating class 150
approx. 30kg
Pressure rating class 600 approx.
35kg
22Setting
Following operation and settings
are available either remotely
through HART or locally by the
magnet key operation. Zero adjustment, Span adjustment,
Output simulation test, Damping
adjustment, Setting of burn-out,
Density.
TG-L1010-0E
APR. 2011K
TG-L1010-2E
JUL. 2012K
MODEL CODE
E S -
Measuring
range
1
2
3
Installation
4
method
5
6
9
1
Material:
2
Bonnet/
3
Displacer/
4
Chamber
9
Enclosure
1
2
3
4
Pressure rating
5
6
7
8
9
1
2
Process connection
3
9
1
2
Torque tube material
3
9
1 2 Cable entry
9 L1 to8
Orientationrotation angleRefer to the
below diagram.
R1 to R8
FST4
1
2
3
4
5
6
7
8
9
1
2
3
4
5
Explosionproof and communication
6
7
8
A
B
6
DESCRIPTION
300 mm or less
301 to 500 mm inclusive
501 to 700 mm inclusive
701 to 1000 mm inclusive
1001 to 1500 mm inclusive
1501 to 2000 mm inclusive
2001 to 2500 mm inclusive
2501 to 3000 mm inclusive
Special
SIDE
SIDE
BOTTOM SIDE
SIDE
TOP
BOTTOM TOP
Top mount
Side mount
Special
SCPH2 / SUS304 / Carbon steel
SCS13A/ SUS304 / SUS304
SCS14A/ SUS316 / SUS316
SCS16A/ SUS316L/ SUS316L
Special
General purpose
Flameproof type
Intrinsically safe type
ASMEJPIClass 150
ASMEJPIClass 300
ASMEJPIClass 600
JIS 10K
JIS 30K
JIS 63K
ASMEJPIClass 1500
ASMEJPIClass 2500
Special
1-1/2 inch flange
2 inch flange
3, 4 inch flangeused only for the installation "5" top mount
Special
SUS316L 196 to 200
INCONEL 196 to 450
NW0276
196 to 200
Special
G1/2F
1/2NPTF
Special
Left hand side
Right hand side
TIIS Flameproof with HART Ex d IIC T6under application
TIIS Intrinsic safety with HART Ex ia IIC T6under application
ATEX & IECEx Flameproof with HART Exd IIC T6
ATEX & IECEx Intrinsic safety with HART Ex ia IIC T6
ATEX & IECEx Flameproof with FOUNDATION Fieldbus Exd IIC T6
under application
ATEX & IECEx Intrinsic safety with FOUNDATION Fieldbus Exia IIC T6
under application
KOSHA Flameproof with HART Exd IICT6
KOSHA Intrinsic safety with HART Ex ia IICT6
NEPSI Flameproof with HART Exd IICT6
NEPSI Intrinsic safety with HART Ex ia IICT6
8
1
5
4
3
4
2
1
6
7
Note: Positions of (2) (4) (6) (8) are not selectable for the pressure rating "1", i.e. ASME class 150.
2
TG-L1010-2E
DIMENSIONS
Fig.1 Transmitter, Torque Tube & Bonnet
(564)
Transmitter
144
50%
91
FST4000
0%
100
%
120
TOKYO KEISO.CO.,JP
Bonnet
132
160
175
232.5
0%
50%
FST4000
100
%
0%
TOKYO KEISO.CO.,JP
100
%
TOKYO KEISO.CO.,JP
150
150
(80)
140
(80)
140
F
50%
320
FST4000
100
%
FFMIN.H + 120
50%
TOKYO KEISO.CO.,JP
FFMIN.H + 320
FST4000
0%
120
FST43
FST42
FST41
140
FST4000
50%
FST4000
100
%
0%
320
0%
50%
100
%
TOKYO KEISO.CO.,JP
120
FST44
FST45
(MIN.H + L
10
T1
FF(MIN.H + 440)
T1
TOKYO KEISO.CO.,JP
TT1 x 2 + 10)
T1 : Thickness of gasket
Details of "A" part
Dimensions
Standard connection flange
Measuring range
Installation dimension
Flange surface to highest
position of span. (Min. 50mm)
Please specify above dimensions when
ordering.
TG-L1010-2E
DIMENSIONS
Fig.3 Assembling of the chamber for class 600
Assembling and mounting dimensions differ with the class 900 and higher classes.
F
FST4000
100
%
0%
50%
FST4000
100
%
0%
TOKYO KEISO.CO.,JP
50%
100
%
TOKYO KEISO.CO.,JP
FFMIN.H + 350
50%
TOKYO KEISO.CO.,JP
350
FST4000
0%
130
(80)
(80)
FFMIN.H + 130
175
175
FST43
FST42
FST41
FST4000
50%
FST4000
100
%
0%
350
0%
50%
F
100
%
TOKYO KEISO.CO.,JP
T1
H
(MIN.H + L
T1
FF(MIN.H + 480)
10
TOKYO KEISO.CO.,JP
TT1 x 2 + 10)
Dimensions
Standard connection flange
Measuring range
Installation dimension
Flange surface to highest
position of span. (Min. 50mm)
130
FST44
T1 : Thickness of gasket
Details of "A" part
FST45
Code
Remarks
V#7020
SS400
Steel
V#8591
SUS304
Stainless steel
V#8596
Carbon steel
V#6596
A320-L7 / A194-4
V#7596
A193-B8CL2 / A194-8
A320-B8CL2 / A194-8
Special
Gasket
Special
TG-L1010-2E
WIRING
Flameproof version
FST4000
1
2
3
4
DC Power supply
Load resistor
Min. 250
CommunicatorCommunicator
Hazardous area
Safe area
Safety barrier
1
2
3
4
4 to 20mA DC
Power supply for safety barrier
CommunicatorCommunicator
Hazardous area
Safe area
TG-L1010-2E
Fieldbus
Terminator
ORDERING INFORMATION
Specify the following for order and inquiry:
1. Model
2. Liquid name
3. Density
4. Temperature Nor. Max.
5. Pressure Nor. Max.
6. Connection
7. Cable entry
8. Measuring range
9. Center to center distance
FST4 - -
NOR.
NOR.
MIN.
MAX.
MAX.
MPa
Head Office : Shiba Toho Building, 1 7 24 Shibakoen, Minato-ku, Tokyo 105 8558
Tel : +81-3 3431 1625 (KEY) ; Fax : +81-3 3433 4922
e-mail : overseas.sales@tokyokeiso.co.jp ; URL : http://www.tokyokeiso.co.jp
6
TG-L1010-2E