AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

ALIAMAG

Electromagnetic Flowmeter
Model AMC2100 Series
Operation Manual

URL: http://www.alia-inc.com
E-mail: alia@alia-inc.com
OP2100.1.1.5.R1ENG

ALIA Group Inc.


113 Barksdale Professional Center, Newark, DE 19711, USA
TEL : +1 - 302 - 213 - 0106
FAX: +1 - 302 - 213 - 0107

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

Index
1. Sensor - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1.1 AMF900 Flange Type - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1.2 AMF500Wafer Type - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

1.3 AMF500 Installation - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2.Installation- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2.1 Install position - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2.2 Remove the interference of magnetic field - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2.3 Straight tube length - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

2.4 Install method - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3. Converter AMC2100 Operate Manual - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3.1 Power and signal output connected line (Compact and separate mode) - - - - - - - - - - - - - -

3.2 Separate wiring - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3.3 AMC2100 Panel deploy - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3.4 Survey mode setting- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3.5 Example - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3.6 Totalizer Reset- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

3.7 Auto zero Adjustment - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10


3.8 Check for power off message - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
3.9 Operate flow chart - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
3.10 User operate description - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 13
3.11 System Mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 16
3.12 Advance Mode- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 17

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

1. Sensor
EM Flowmeter composed by sensor and Converter, be compact version or separate version, there are several
specification of sensor as follow:
98

60

Size: 6mm ~ 2000mm (1/4 ~ 80)


Liner : Neoprene
Polyurethane
FEP
PTFE
PFA
Protection : IP68
Max.Temp.:180 Deg. C
Installation : Flange End

48

1.1 AMF900 Flange Type

Size

Standard
Pressure

(mm)

Kg/cm2

Liner Material
FEP / PFA

Neoprene

Polyurethane

Dimensions (mm)
PTFE

6
10
15

90

145

95

155

105

160

115

166

140

180

40

150

190

50

165

201

185

220

200

235

220

254

250

284

150

20
25
32

40

200

65
80
100
125

250

16

150

300

285

314

200

350

340

369

250

400

395

430

445

480

505

540

500

565

600

550

615

640

670

700

780

800

300

450

350
400
450
500

10

600

600
700

700

895

910

800

800

1015

1020

900

900

1115

1120

1000

1000

1230

1230

1200

1200

1405

1450

1400

1400

1630

1560

1600

1830

1770

1800

1800

2045

2040

2000

2000

2265

2250

1600

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

1.2 AMF500 Wafer Type


Size: 25mm ~ 200mm (1 ~ 8)
Liner:FEP
Protection:IP68
Max.Temp.: 180 Deg. C
Installation: Wafer

Size

Dimensions (mm)

mm

Inch

25

1"

90

67

142

32

1-1/4"

76

152

40

1-1/2"

87

160

50

2"

110

100

175

65

2-1/2"

120

120

195

80

3"

130

135

210

100

4"

145

155

230

125

5"

160

185

260

150

6"

175

210

285

200

8"

200

265

340

100

1.3 AMF500 Installation

Tie-rod
Nut

Packing
Flange

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

2. Installation
When you design the tube, please consider following items:

2.1 Install position


Please avoid the sunlight when you install the flowmeter, the ambient temperature between-25~60 Deg.C will be great.
2.2 Remove the interference of magnetic field
Please DO NOT install flowmeter near motor-driven machine,transformer,frequency transformer.etc.for it will cause interference of
magnetic field..

2.3 Straight tube length


In order to guarantee the EM Flowmeter accuracy, upstream and downstream of the installation should satisfied the following
conditions(Picture).

T - Tube
ELBOW 90

> 5D

> 5D

> /2

Grove Valve

When the upside and downside is shrink tube,


the degree should be smaller then 15

> 10D

Generally tube installation, the flowmeter Upstream could try to stay 5D-10D ,Downstream 2D-5D.

2.4 Install method


a. Flowmeter can be horizontal, vertical or slanting, please make sure the tube is full of fluid no matter if it is
moving or not.
b. When fluid contained solid material, Its suggested to try vertical installation(bottom to top), which can avoid the
solid material sink inside the tube.

c. Pipe design should make sure no air bubble in the flowmeter position.

F:
123 . 4 m3 /H
F:
5 6. 7 m/ S
T: 123 4 .56 7 8 m3
A MC 30 00 S e ri es
SET

F:
123 . 4 m 3/H
F:
5 6. 7 m/ S
T: 123 4. 56 78 m 3
A M C 30 00 S e ri es
SET

ESC

F: 123.4 m3 /H
F: 56.7 m/S
T: 12 34.5678 m3
AMC 3000 Seri es

SET

F: 123. 4 m3 /H
F: 56.7 m/S
T: 12 34.5 678 m3
AMC 3000 Seri es

ESC

SE T

ESC

ESC

AMC2100 Operation Manual


OP2100.1.1.5.R1ENG
d. Electrode position should parallel with ground
EM Flowmeter installed by horizontal or slanting the electrode position(A.B) should match the 2 side( right/left)of
tube, converter(wiring box)should be top of the tube.

Exhaust valve

>3m

Horizontal install, the electrode position A.B should on the right and left side.

e. Transportation
When you moving, please remember DO NOT use rope through the flowmeter tube, it may cause Liner inside
broken.
Please DO NOT use your hand or rope to hang on Converter or wiring box, if Flowmeter size is bigger than 80mm,
because the material of converter and wiring box is tender aluminum, it cant stand huge weight.

f. Grounding measure
Grounding
Ring

Grounding resistance < 10

General metal tube

Non-metal tube (plastic tube Liner)

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3. Converter AMC2100 Operate Manual


3.1 Power and signal output connected line(compact and separate model)
Open the 4 screws of the converter, and you can see terminal, decide if you need to connect according to your
needs.

F
U
S
E

I+

I-

P+ R+
P- RP-

L N

1 .4 ~ 20mA output +
2.4~ 20mA output -

3. Pulse output +
4. Pulse output 5 . RS485 output +
6. RS485 output -

Power supply
90 ~ 260V AC
50/60Hz
or
24VDC

Cable from sensor

1
+

3
-

mA
Load

Output a load: 600

4~20mA Output
( Hart protocol)

Load

Max. Outer Voltage: 30VDC

Modbus protocol

Pulse (Frequency)
Output

RS485 Output

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.2 Separate Wiring


Converter
AM C2100
series

Coil

Electrode

Sensor
AM F500
AM F900
series

3.3 AMC2100 Panel deploy

70 mm

123.456 m3

Key
Name
Setting

Up

Right

Button
Sign
ENT

150 mm

150 mm

+0.000 m3/h

Normal status function

Parameter setting status function


Save presently settled parameter. Jump to next
parameter setting

Login parameter setting level

Selected one of 4 display line

Change present digit, dot and survey unit.


Up/Down movement

Change the selected line on the display

Move

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.4 Survey mode setting


Flowmeter will enter to normal mode when electrified, every line has several choice as follow:
Position

Display
Unit sign
Unit
Totalizer

L, M3, G , kg, T
Totalizer+
+
Totalizer
Velocity
m/s
Flowrate
m3/h
% of Full Scale
FS%

Line 1

Line 2

mA output
value
Frequency

Description
= + ()

mA

When reverse flow, it will show-


When reverse flow, it will show-
Actual flowrate should match
flowrate%
Actual mA output Value

Hz

Full scale output : 5000Hz

3.5 Example
If you need Line 1 display from m3/h turn to %

123.456 m3

+0.0000m3/h
V

123.456 m3

+0.0000m3/h

In normal display press

button until Line 2 is selected.

123.456 m3

+0.0000 %FS

Press

ENT

button to change m3/h to %FS

3.6 Totalizer Reset

123.456 m3

+0.0000m3/h

In general display, Press

or

button and select

,make sure enter zero window

V
ENT

1
2

123.456 m3
123.450 m3
123.400 m3

EXIT

HELP

Zero window.
.current totalizer value
1.last totalizer value
2.the time before last time totalizer value
Please selected CLR and press enter,doing the zero operation

CLR

ENT

Clear
NO

Total

Select YES for making zero operation and press

YES

ENT

to confirm

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.7 Auto zero Adjustment


When the tube are full pipe, and no flow, flowmeter still show the flowrate, then you could use Auto Zero adjustment
to adjust your flowmeter to Zero, the method as follow:

123.456 m3

In the normal display, press

ENT

button for 5 seconds, then it will go to next setting

+0.1234m3/h
V
ENT

OPERATIONS
SET

ZERO

In this setting, Press

or

Select YES, and press

ENT

button till you selected ZERO and press

ENT

to confirm

ESC

ENT

ZERO
NO

to confirm .

YES

ENT

Condition OK ?
NO

YES

Select YES, press

ENT

to confirm and start Zero Adjustment.

HELP

ENT

Zero Adjustment.
Zero

Triming

ENT

Zero Tirm End


-2.624mv
Zero

Zero Adjustment end. Select ESC, press


to turn back to the operations select
(If you want to do Zero Adjustment again, Pls select ZERO )
ENT

Esc
ENT

OPERATIONS
SET

ZERO

Select ESC, press

ENT

to confirm and turn back to the normal display

ESC

ENT

123.456 m3

the normal display

+0.0000m3/h
V
3.8 Check for power off message

123.456 m3

+0.0000m3/h

In general display, Press or


power off message window

button to select

Press ENT to confirm, then check for the

V
ENT

ON

Power off message window


2008/04/23
13:30:55

OFF

2008/04/23
13:30:55

Q:
:

1.0234 m3/h
4.321 m3

ON : date and time for power on


OFF : date and time for power off
the flowrate for power off
:the totalizer when power off
Example: 01 means the power off recored series No.(It could record 99 times of power off)
Press PgUP or PgDN check the history record of power off.
Ps: Press PgDN till the last page, OFF option means current date, time, and flowrate.

01 PgUP PgDN ESC

10

Q:

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.9 Operate flow chart

123.456 m3

+0.0000m3/h
V
ENT

OPERATIONS
SET

ZERO

ESC

ENT

Password
ENT

0000

Empty Detect

Language
ENT

ENT

PV Units

Empty Limit(%)
ENT

Communication

ENT

ENT

URV
MODBUS Type

ENT

ENT

ENT

Switch Func

Baudrate

ENT

Liter/Pulse
ENT

Freq of URV (Hz)

ENT

Parity

ENT

Pulse Width
ENT

Alarm

Select

ENT

Modbus Address

ENT

Low Cutoff(%fs)

UPPER-Alarm

ENT

DATE (yy-mm-dd)

ENT

ENT

Damping(s)

TIME (hh-mm-ss)

ENT

Hydro-State

ENT

ENT

Direction
ENT

11

HART Address

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

ENT

Password

Password

****

1111

Sensor NO.

Sensor NO.
ENT

ENT

Diameter (mm)

Diameter (mm)

ENT

ENT

Sensor Factor

Sensor Factor

ENT

ENT

Output Check

Output Check
ENT

ENT

Loop

Restore Shipping
ENT

Restore Shipping

Test

ENT

ENT

Pulse

Convertor NO.

Test

ENT

ENT

Coil

Test

Convertor Factor
ENT

Coil Current (A)


ENT

Coil Freq (Hz)


ENT

Zero Factor
ENT

4mA

Trim

ENT

20mA Trim

12

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.10 User operate description

123.456 m3

+0.0000m3/h

In the normal display, press

ENT

button for 5 seconds, then it will go to next setting

V
ENT

OPERATIONS
SET

ZERO

In this setting, Press

or

button till you selected SET

ESC

ENT

Password login window

Password

Input the password


Password: 0000

0000

ENT

Language

Language

CHINESE ENGLISH

Press

or

to selected the language

ENT

PV Units
m3/h L/h GPH
Kg/h t/h GPM
L/min m3/min

Select Flow Engineer unit


Press
or
to select the Engineer unit
0: m3/h
1: L/h
2: GPH
3: Kg/h
6: L/min
7: m3/min

4: t/h

5: GPM

ENT

URV

m3/h
70.0000

Flow Range
Setting Flow Range, thats mean 4-20mA and Pulse, frequency output max. Value
Press
button to move, Press to change the Value

ENT

Switch

Contact output

Func

Default
Freq

Pulse
Alarm

Press
or
1. Default

button to selected the output


2. Pulse
3. Frequency

4. Alarm

ENT

Liter/Pulse

(L/P)
0.1000

Pulse output
Each pulse match the Liter value (Liter/Pulse)
Press button to move, Press to changed the Value

ENT

Pulse width

Pulse Width
1ms
10ms
100ms 1s

20ms
50%

Press

or

to selected Pulse width

ENT

Low

Cutoff (%fs)
0.0

Function for cutoff the low flowrate


Press button to move, press
Setting Range: 0.0% ~ 9.9%

button to change the Value

ENT

13

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

The flowrate response time setting,

Damping (s)
01

Press button to move, Press button the Value


Setting Range:01 ~ 99 Seconds, Factory Standard set value is 2 Seconds

ENT

Hydro-State

Hydro State
Normal

Waved

Press
or
button to selected the Hydro-State
Normal: for general application
Waved: For fluid in wave states

ENT

Response speed adjustment

Max Limit (%fs)


05

Press button to move, Press


button to change the value
Range: 00~30%, 1% means max 1% flowrate value change for each Limit Time

ENT

Response time

Limit Time (s)


05

Press
button to move, Press
to change the value
Response time range: 00~99, Adjust flowmeter response time.

ENT

Direction

Direction
Fwd.

Press or
1. Forward

Bid.

button to select the Hydro-state


2. Bidirection

ENT

Empty pipe detect

Empty Detect
NO

Press

YES

or

button to select if it needs empty pipe detect

ENT

Empty pipe detect the value

Empty Limit (%)

Press

button to move, Press

to change the value

50
ENT

Communication
OFF

ON

Communication
Press

or

button to select if need to use communication function

HART

Address

ENT

Please read page 15


00

MODBUS

Type

RTU

ASCII

MODBUS Mode
Press

or

button to select MODBUS mode

ENT

14

AMC2100 Operation Manual

Baudrate
1200
4800
19200

2400
9600
38400

OP2100.1.1.5.R1ENG

RS485 Speed
Press

or

button to select communication speed.

ENT

Parity

Parity Type

NONE ODD EVEN

Press or
button to select the parity type
1. None 2. Odd 3. Even

ENT

MODBUS Address
001

MODBUS address
Press

button to move, Press

button to change the digit

ENT

DATE (yy-mm-dd)

Date Setting
Press

button to move, Press

button to change the digit.

08-01-10
ENT

TIME (hh:mm:ss)

Time Setting
Press
button to move, Press
button to change the digit.
button for 5 seconds, then it will go back to the normal display.
Pls press
ENT

17:09:49

HART operate description


HART

HART Address

Address
00

Press

or

button to select HART Address

ENT

DATE (yy-mm-dd)

Date Setting
Press

button to move, Press

button to change the digit.

08-01-10
ENT

TIME (hh:mm:ss)

Time Setting
Press
button to move, Press
button to change the digit.
button for 5 seconds, then it will go back to the normal display.
Pls press
ENT

17:09:49

15

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.11 System Mode


OPERATIONS
SET

ZERO

ESC

In the normal display, press


button for 5 seconds, then it will go to next setting
In this setting, Press or
button till you selected SET
ENT

ENT

Password login window

Password

Input the system password:


Password: 1111

1111

ENT

Sensor No.

Sensor NO.

Press

button to move, Press

button to change the digit.

A7082106
ENT

Diameter

Diameter (mm)

Press

button to move, Press

button to change the diameter

0065
ENT

Sensor Factor KS

Sensor Factor
00.94100

KS is the original factory rectified factor, please dont change it unless professional or technical staff
button to change the value
Press button to move, Press

ENT

Output Calibration

Output Check
NO

Press
or
button to choose YES select if needs calibration
Choose NO jump to Restore Shipping

YES

ENT

Loop

Test

16

4-20 mA simulated output


12

Press
or
button to select the simulated output value
4 . 8 . 12 . 16 . 20

100

Pulse Simulated output


or
button to select the calibration type
Press
1 . 10 . 100 . 1000 . 2000 . 5000

20

ENT

Pulse Test
1
1000

10
2000

5000

ENT

Coil

Test

ON

XJY

Excit voltage calibration


YJX

Check the coil X to Y or Y to X excit signal are correct or have fail


or
button to select the calibration type
Press
Choose X->Y, the Voltage will be 24VDC, Choose Y->X, then Y to X will be 24 VDC

ENT

Restore
NO

Shipping
YES

Restore the parameter to second memory


Press
or
button to select if it needs to restore the factory setting
button for 5 seconds, then it will go back to the normal display.
Pls press
ENT

16

AMC2100 Operation Manual

OP2100.1.1.5.R1ENG

3.12 Advance Mode


OPERATIONS
SET

ZERO

ESC

In the normal display, press


button for 5 seconds, then it will go to next setting
In this setting, Press or
button till you selected SET
ENT

ENT

Password login window

Password

Input the system password:


Password: * * * *

****

ENT

Sensor No.

Sensor NO.

Press

button to move, Press

button to change the value

A7082106
ENT

Diameter (mm)

Diameter
Press

button to move, Press

button to change the diameter

0065
ENT

Sensor Factor KS

Sensor Factor
00.94100

KS is the original factory rectified factor, please dont change it unless professional or technical staff
button to change the value
Press button to move, Press

ENT

Output Calibration

Output Check
NO

Press
or
button to choose YES select if needs calibration
Choose NO jump to Restore Shipping

YES

ENT

Loop

Test

16

4-20 mA simulated output


12

20

Press
or
button to select the calibration type
4 . 8 . 12 . 16 . 20

ENT

Pulse Simulated output

Pulse Test
1

10
1000 2000

100
5000

Press
or
button to select the calibration type
1 . 10 . 100 . 1000 . 2000 . 5000

ENT

Coil

Test

ON

XJY

Excit voltage calibration


YJX

Check the coil X to Y or Y to X excit signal are correct or have fail


or
button to select the calibration type
Press
Choose X->Y, the Voltage will be 24VDC, Choose Y->X, then Y to X will be 24 VDC

ENT

17

AMC2100 Operation Manual

Restore

Shipping

NO

OP2100.1.1.5.R1ENG

Restore the parameter to second memory


Press

YES

or

button to select if it needs to restore the factory setting

ENT

Converter No.

Converter NO.

Press

button to move, Press

button to change the value

B0000000
ENT

Converter

Factor
01.05988

Converter Factor KC
Press

button to move, Press

button to change the value

ENT

Coil

Coil Current IC(A)

Current (A)
0.1654

Ic is the tested current of the converter when out of factory, please dont change it unless agent or
professional technical staff.
button to move, Press button to change the value
Press

ENT

Coil
3.125

Coil Frequency (Hz)

Freq (Hz)
6.25

33

Press
or
button to select the coil frequency
Original setting Value: 6.25

ENT

Zero

Zero Factor manual setting

Factor

Press

button to move, Press

to change the value

- 9.9
ENT

4mA

4mA output calibration

Trim

Press

button to move, Press

to change the Value

4.000
ENT

20mA

20mA output calibration

Trim

Press
button to move, Press
to change the value
button for 5 seconds, then it will go back to the normal display.
Pls press
ENT

20.000

18