Sie sind auf Seite 1von 4

Digitron VAP Series of Panel Indicators

Digitrons VAP Series offer a range of high accuracy performance panel meters designed for
use with pressure transducers, high voltage transducers and current loop sensors.
Features include:
Highly accurate performance
Large LED display
Easy to use
Controller model
Superb value
Compact design
All models incorporate a decimal point position selection and continuous scaling of
gain, from full scale > 250 to < 1999, using jumper links, zero and gain adjustment
control
The VAP Series are supplied with a set of standard engineering units for
customer use. The appropriate symbol should be fixed to the front panel.
A440 SERIES CURRENT LOOP INDICATORS
Digitrons A440 Series current loop indicators are
designed for use with any current loop sensor, which
gives out a dc current in the range 0-20mA, or 420mA.
0mA or 4mA zero inputs are selectable, with
further offset adjustment for sensor calibration
(using jumper links). Both instruments give out a
nominal excitation voltage of 24V dc and can also be
used as repeaters on loops, which are already
powered.
Two models are available:
The model A445 indicator and the model A448 indicator with single set point.

Tempcon Instrumentation Ltd.


Unit 19, Ford Lane Business Park, Ford Lane
Ford, Nr. Arundel, West Sussex. BN18 0UZ
Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

B324

Email: info@tempcon.co.uk
Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators


P440 SERIES PRESSURE INDICATORS
Digitrons P440 Series pressure indicators are designed for
use with pressure transducers with a full-scale output 100mV
or other strain gauge device.
Two models are available:
Model P445 indicator and model P448 indicator with single
set point.
The instruments give a 10V dc excitation voltage and can be
adjusted to give full-scale indication for other than 100mV
using jumper links, zero and gain adjustment control.
V440 SERIES BRIDGE TRANSDUCER INDICATOR
The V440 series transducer Indicators are designed for
use with any 3 terminal transducer which requires a
nominal + 24V dc excitation voltage and gives out a
signal in the range 0-5V or 0-10V dc (1-6V, 1-11V dc with
offset).
Two models are available:
Model V445 indicator, and model V448 indicator with
single set point each with 2 ranges, 0-5V (1-6Vdc with
offset). or 0-10V (1-11V dc with offset). Both instruments
give out a nominal excitation voltage of 24V dc.
Reliability
All models are subjected to detailed inspection and a rigorous testing programme before
being calibrated. All models are also supplied with a 12 month warranty on parts and labour

Tempcon Instrumentation Ltd.


Unit 19, Ford Lane Business Park, Ford Lane
Ford, Nr. Arundel, West Sussex. BN18 0UZ
Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

B324

Email: info@tempcon.co.uk
Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators


Applications
Application
Air
Amps/Volts/Power
Compressors
Displacement
Engines
Flow
Frequency
Gas

A440

P440
X

V440
X

X
X

X
X

X
X

X
X
X

Heating & Ventilating

Industrial Hydraulics
Oil
pH
Pressure
Refrigeration
Speed
Strain
Temperature
Water

X
X
X
X

X
X
X

X
X
X

Tempcon Instrumentation Ltd.


Unit 19, Ford Lane Business Park, Ford Lane
Ford, Nr. Arundel, West Sussex. BN18 0UZ
Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

X
X
X
X

B324

Email: info@tempcon.co.uk
Web site: www.tempcon.co.uk

Digitron VAP Series of Panel Indicators


Specification

A440
Input

Transducer/Excitation
Voltage
Display
Range-Full Scale

Decimal Point Position


Indicator Accuracy
Power Supply
Zero Offset Control
Operational
Temperature Range

P440

V440

0-20mA full scale or 420mA full scale selectable


with jumper link

100mV full scale output

24V dc nominal

10Vdc

24dc nominal

31/2 digit, 13.5mm LED

31/2 digit, 13.5mm LED

31/2 digit, 13.5mm LED

Adjustable from. 250 to


1999 Counts

0-5, 1-6V dc pre-set by


manufacturer or 0-10, 1-11V
dc (please specify)

Adjustable from. 250 to 1999 Adjustable from. 250 to 1999 Counts


Counts

Selectable using jumper link

Selectable using jumper link

Selectable using jumper link

Linearity 1 digit
Stability typically 100ppm/C

0.2% of reading 1 count

Linearity 1 digit
Stability typically 100ppm/C

230/115V ac 15%
(selectable), 50/60 Hz

230/115V ac 15%
(selectable) 50/60 Hz

230/115V ac 15% (selectable),


50/60 Hz

Adjustable pots and jumper Adjustable pots and jumper


links access from behind
links access from behind
front panel
front panel
0-40C

0-40C

Adjustable pots and jumper links


access from behind front panel
0-40C

Dimensions
Cut Out

96x48x68.1mm (after DIN


43700) 92x45mm + 1.0mm
0.0mm

96x48x68.1mm (after DIN


68.1mm (After DIN 43700)
43700) 92x45mm + 1.0mm- 96 x9248x x45mm
+ 1.0mm 0.0mm
0.0mm

Changeover Relay

Heavy duty silver Cadmium


Oxide 5 amps resistive load
@240V ac

Heavy duty Silver Cadmium


Oxide 5 amps resistive load
@240V ac

Setpoint Hysteresis

pot (1 count up Adjustable pot ( 1 count up to


Adjustable pot (1 count up toAdjustable
10 counts) access through 10
to 10 counts), access
counts) access through vents
vents on right hand side of
through vents on right
on right hand side of case.
case.
(Model A448 only)
(Model V448 only)
(Model P448 only)

Tempcon Instrumentation Ltd.


Unit 19, Ford Lane Business Park, Ford Lane
Ford, Nr. Arundel, West Sussex. BN18 0UZ
Tel: +44 (0) 1243 558270 Fax: +44 (0) 1243 558288

B324

Heavy duty Silver Cadmium Oxide


5 amps resistive load @ 240V ac

Email: info@tempcon.co.uk
Web site: www.tempcon.co.uk

Das könnte Ihnen auch gefallen