Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

Upto 100 mm

1.4 m

Using Grade 0 Blocks


By Comparison Method

Upto 100 mm
100 mm to 200 mm
200 mm to 400 mm
400 mm to 600 mm

3.5 m
5.0 m
7.3 m
8.5 m

Using Grade 0 Blocks


By Comparison Method

Upto 100 mm

4.1 m

Using Grade 0 Blocks


By Comparison Method

Upto 600 mm
Upto 600 mm

15.0 m
18.5 m

Using Caliper Checker


By Comparison Method

Upto 600 mm
Upto 600 mm

16.0 m
19.5 m

Using Caliper Checker


By Comparison Method

Upto 300 mm

15.0 m

Using Grade 0 Blocks


By Comparison Method

0.01mm to 10 mm
0.001mm to 1 mm

4.7 m
1.7 m

Using Electronic dial


calibration tester
By Comparison Method

I. DIMENSION
1.

OUTSIDE
MICROMETER$
L.C. 0.001mm

2.

OUTSIDE
MICROMETER$
L.C. 0.01 mm

3.

INSIDE MICROMETER$
L.C.0.01 mm

4.

5.

VERNIER CALIPERS$
L.C. : 0.01/ 0.02 mm

HEIGHT GAUGE$
L.C. : 0.01 / 0.02 mm

6.

DEPTH VERNIER$

7.

PLUNGER DIAL$

Laboratory

Microtech Calibration Lab, Plot No. 143, Indira Housing Society, Kabnoor,
Ichalkaranji, Kolhapur, Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Mechanical Calibration

Issue Date

03.03.2014

Certificate Number

C-0229

Valid Until

02.03.2016

Last Amended on

Page

2 of 6

Quantity Measured/
Instrument

8.

9.

10.

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

LEVER TYPE DIAL$


L.C. 0.01 mm

Upto 1mm

3.8 m

L.C. 0.001 mm

Upto 1mm

1.6 m

Using Electronic Dial


Calibration Tester
By Comparison Method

All range Upto 1.5mm


stroke

2.5 m

Using Electronic Dial


Calibration Tester
By Comparison Method

Upto 50 mm

58.0 m

Using Grade 0 Gauge


Blocks
By Comparison Method

Upto 150 mm

10.4 m

Electronic Sylvac Dial


with Comparator Stand
By Comparison Method

BORE GAUGE$
(Transmission Accuracy
only)

PISTOL CALIPER$
L.C. 0.1mm

11.

V BLOCK$
(Parallelism &
Squareness
Symetricity)

12.

MEASURING SCALE $
L.C. 1.0 mm

Upto 1000 mm

144 m

Electronic Scale & tape


Calibration Unit
By Comparison Method

MEASURING TAPE$
L.C. 1.0 mm

Upto 5000mm

250.0 m

Using Electronic Scale


& tape Calibration Unit
By Comparison Method

13.

Laboratory

Microtech Calibration Lab, Plot No. 143, Indira Housing Society, Kabnoor,
Ichalkaranji, Kolhapur, Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Mechanical Calibration

Issue Date

03.03.2014

Certificate Number

C-0229

Valid Until

02.03.2016

Last Amended on

Page

3 of 6

Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

DEGREE PROTECTOR$
L.C.1

0 to 90 to 0

40 min of arc

Using Angle Gauge


Blocks
By Comparison Method

BEVEL PROTECTOR$
L.C. 5

0 to 90 to 0

5 min of arc

Using Angle Gauge


Blocks
By Comparison Method

COMBINATION SET$
L.C.1

0 to 90 to 0

40 min of arc

Using Angle Gauge


Blocks
By Comparison Method

17.

FEELER GAUGE$

Upto 5.0mm

1.2 m

Using Electronic Sylvac


probe with Comparator
Stand
By Comparison Method

18.

CYLINDRICAL
SETTING MASTER$

Upto 100mm
100 mm to 300mm

1.7 m
3.3 m

Using Electronic Sylvac


probe with Comparator
Stand
By Comparison Method

19.

SETTING PIECE /
LENGTH BAR$

Upto 100mm
100 mm to 300mm

1.7 m
3.3 m

Using Electronic Sylvac


probe with Comparator
Stand
By Comparison Method

14.

15.

16.

Laboratory

Microtech Calibration Lab, Plot No. 143, Indira Housing Society, Kabnoor,
Ichalkaranji, Kolhapur, Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Mechanical Calibration

Issue Date

03.03.2014

Certificate Number

C-0229

Valid Until

02.03.2016

Last Amended on

Page

4 of 6

Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

4mm to 300mm

4.2 m

Using Length
Measuring Machine

Upto 200mm

4.9 m

Using Grade O Gauge


Block
By Comparison Method

20.

PLAIN RING GAUGE$

21.

DIAL SNAP GAUGE$

22.

COMPARATOR STAND
FLATNESS OF PLATE$

200mmx200mm

3.5 m

Using Electronic Probe


Comparator
By Comparison Method

23.

PLAIN PLUG GAUGE$

Upto 100mm
100mm to 300mm

1.7 m
3.3 m

Using Electronic Sylvac


probe with Comparator
Stand
By Comparison Method

24.

SNAP GAUGE$

2mm to 300mm

4.2 m

Using Slip gauge LMM


300mm
By Comparison Method

25.

THREAD PLUG
GAUGE $
(Effective Dia Only)

2mm to 100 mm

3.0 m

Using Floating Carriage


Dia Measuring Machine
By Comparison Method

26.

THREAD PLUG
GAUGE$
(Effective Dia Only)

100mm to 300mm

4.1 m

Using Universal Length


Measuring Machine
300mm

27.

TAPER THREAD PLUG$


(Effective Dia Only)

2mm to 100 mm

4.5 m

Using Floating Carriage


Dia Measuring Machine
By Comparison Method

Laboratory

Microtech Calibration Lab, Plot No. 143, Indira Housing Society, Kabnoor,
Ichalkaranji, Kolhapur, Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Mechanical Calibration

Issue Date

03.03.2014

Certificate Number

C-0229

Valid Until

02.03.2016

Last Amended on

Page

5 of 6

Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

2mm to 100 mm

2.0 m

Using Universal Length


Measuring Machine
300mm

100mm to 300mm

4.2 m

Using Universal Length


Measuring Machine
300mm

11.8 m

Using Taper mandrel &


Parallel Mandrel with
Electronic Dial
By Comparison Method

28.

THREAD RING GAUGE$


(Effective Dia Only)

29.

THREAD RING
GAUGE$

30.

BENCH CENTRE
(Co-axillity &
Parallelism)

Upto 500mm

31.

SURFACE PLATE

400mm x 400mm to 2000


mm x 2000 mm

6.0

L+ W
125

Where L&W is in mm
32.

PROFILE PROJECTOR
L.C.0.001mm

Using Precision Spirit


Level
By Comparison Method

Linear 0 to 100
Angular 0 to 360
Magnification 10x20x

8.8
3.0 min
1.0 %

Using Precision Glass


Scale
Angle Gauge & Slip
Blocks

Upto 700 bar

0.35% FSD

Using Electronic
Pressure Calibrator
As per DKD R-6-1
By Comparison Method

II. PRESSURE
1.

PRESSURE GAUGE#
(Analogue/ Digital)

* Measurement Capability is expressed as an uncertainty () at a confidence probability of 95%


$

Only in Permanent Laboratory


Only for Site Calibration

Laboratory

Microtech Calibration Lab, Plot No. 143, Indira Housing Society, Kabnoor,
Ichalkaranji, Kolhapur, Maharashtra

Accreditation Standard ISO/IEC 17025:2005


Discipline

Mechanical Calibration

Issue Date

03.03.2014

Certificate Number

C-0229

Valid Until

02.03.2016

Last Amended on

Page

6 of 6

Quantity Measured/
Instrument

Range / Frequency

*Calibration Measurement
Capability ()

Remarks

The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual
environmental conditions and master equipment used.

Das könnte Ihnen auch gefallen