Sie sind auf Seite 1von 4

Lindab Butler m e t a l b u i l d i n g s y s t e m s

Butler Building Systems


Butler Building Systems
Evans Business Centre
Mitchelston Industrial Estate
Lindab Butler Building Systems
Service Centre
HBV-Hallen + Bausysteme Vertrieb
Lindab Butler Building Systems
Representative Office
International Trade Center
Lindab Butler Building Systems
Lindab s.r.o.
Zděbradská 56
Butler Building Systems
Mitchelston Drive Franz-Kissing Str. 7. Bd. Al. Vlahuta 10. office No. F8 Říčany
Kirkcaldy Fife 58 706 Menden, Germany Brasov 251 01 Czech Republic
Scotland, KY1 3UF Tel: +49 2373 926 130 2200 Romania Tel: +420 323 627 111
Tel: +44 (0) 1592 652 300 Fax: +49 2373 926 133 Tel: +40 268 324 618 Fax: +420 323 637 463
Fax: +44 (0) 1592 653 135 Mobile: +49 172 77 52 175 Fax: +40 268 326 431

Lindab Sp. z o.o.


Lindab Butler Building Systems
ul. Kolejowa 311, Sadowa
Lindab Butler Building Systems
Derkovits u. 106-108.
Nyíregyháza
www.lindab-butler.com Structural Systems
05-092 Łomianki, Poland 4400 Hungary
Tel: +48 (22) 751 88 90 Tel: +36 (42) 501 310
Fax: +48 (22) 751 96 67 Fax: +36 (42) 312 029

Office in Poznań: Representative Office:


ul. Św. Michała 43 Alkotás u. 39/c
61-119 Poznań Budapest
Poland 1123 Hungary DUISBURG
Tel: +48 (61) 650 36 86 Tel: +36 (1) 489 46 70 GmbH
Fax: +48 (61) 650 36 89 Fax: +36 (1) 489 46 80 Anerkannte Ausbildungs-, Prüf-, Überwachungs-
und Zertifizierungsstelle
Akkredititerte Prüflaboratorien
Truss Beam Framing for roof openings Portal Brace
(optional)
Roof Purlin
Parapet
Crane Support
Steelwork

Wind Bracing

Multi-Storey
Building

Beam and Framed wall


Post Endwall openings
Intermediate (LRF)
Rigid Frame

X
1 ROOF SLOPE

Bay Spacing
6 m to 12 m
The WIDESPAN Structural System
EAVE HEIGHT

CLEAR HEIGHT

is versatile and economical.


The proven economics of rigid frame
construction provides unlimited
Rigid Frame
design flexibility. Endwall (WX)
Intermediate
STRUCTURAL LINE
(extendable) Canopy Width Extension Wall Girt
W=WIDTH (OUTSIDE FACE OF
WALL GIRTS)
(MRF)
Rigid Frame

WIDESPAN Structural System


Building Type Type Description Width Eave Height Min. Roof Slope Building Type Type Description Width Eave Height Min. Roof Slope

12.00 m – 23.00 m 4.00 m – 9.00 m 1:48 Clearspan


MP 6.00 m – 21.00 m 4.00 m – 6.00 m 1:48
Mono Pitch

24.00 m – 42.00 m 4.00 m – 12.00 m 1:24 WX Width 6.00 m – 12.00 m 3.00 m – 7.00 m 1:48
Extension
LRF Clearspan

over 42.00 m 5.00 m – 12.00 m 1:12


MRF Modular 24.00 m – 90.00 m 4.00 m – 9.00 m 1:48

CRB Clearspan 15.00 m – 30.00 m 4.00 m – 6.00 m R=Wx2


Curved Roof R=Radius

Note: For other dimensions contact your local Lindab Butler Sales Office.
Lindab Butler m e t a l b u i l d i n g s y s t e m s

SYSTEMLINETM
TM
The SYSTEMLINE Structural System
offers economy and flexibility for
spans from 10 m to 25 m, especially
where high roof slopes are required.
The primary frames are fabricated
from standard hot rolled profiles.

MULTI-STOREY STRUCTURAL SYSTEM


The Multi-Storey Structural System offers all the benefits of systems construction and the reliability
of Lindab Butler's technology and products.

Multi-Storey and Mezzanines

TRUSS STRUCTURAL SYSTEM


The system combines truss roof beams supported on steel or concrete columns and pre-punched galvanized
purlins and girts.

Multi-Storey and Mezzanine support steel to suit various floor construction details, including precast concrete units, metal
deck with concrete topping or site cast concrete floors.
Lindab Butler m e t a l b u i l d i n g s y s t e m s

Design Specifications
Crane Supports
Structural design is in accordance with specific country requirements and generally in accordance with the requirements of the applicable
Eurocodes.
Building reactions and anchor bolt layout drawings are supplied as part of the structural design documentation package, for use by the foundation
design engineer.
General arrangement drawings will be supplied for approval if requested.

Material Specifications
Structural Steel Structural Galvanised Steel Strip
Material shall conform to: Material for cold formed light gauge structural members including
– EN10025 for technical delivery conditions purlins and girts shall conform to:
CANTILEVER BRACKET STEPPED COLUMN BRACED COLUMN – EN10029 for tolerances – EN 10147 for technical delivery conditions
(LIGHT CAPACITY (MEDIUM CAPACITY (HEAVY CAPACITY
CRANES) CRANES) CRANES) Steel quality shall conform to: – EN 10143 for tolerances
– S355J2G3 for welded sections Steel quality shall conform to:
– S235 for hot rolled sections – EN 10147-S350+Z275 N-A-CO
Where 350 = minimum yield strength in N/mm2
Secondary Structural Components Surface Preparation and Coatings Z275 = coating weight in g/m2
Primarily consisting of cold formed Z and C sections, available in depths ranging Surface preparation (shotblasting) for all primary structural elements N = normal spangle
from 100 mm to 350 mm and thicknesses from 1.0 mm to 3.0 mm. shall be in accordance with ISO 8501-1: A Sa2½. A dry film thickness of A = as coated surface
40 microns “Korrodur+” primer paint shall be applied to all primary CO = chemically passivated and oiled
structural elements. The primer paint is Alkyd resin based with high build Minimum yield strength 350 N/mm2
zinc phosphate. This primer is intended to protect the steel during the Minimum tensile strength 420 N/mm2
erection process, however, in non-corrosive, indoor conditions, expe-
rience has shown that this one layer will successfully protect the steel
work without application of a top coat. Hollow Structural Sections
Where further protection is required, the following options are available: Material shall conform to:
a) Tri-coat layers: second and third layers consisting of 40+40 microns KH – BS EN 10210-1; Designation S 275 J2H
kombilack quick drying finish paint consisting of a combination of PVC Tolerances and Section Properties shall be in accordance with:
and acrylate. – BS 4848 Part 2 - 1991 or DIN 59410
b) Fire protection: Based on Deutsches Institut für Bautechnik certificate Mechanical Properties:
(Z-19.11-329) Minimum yield strength 275 N/mm2
F30 = 30 minutes fire protection paint system (600 microns) Minimum tensile strength 430 N/mm2
Overlapped purlins provide strength with maximum Typical girt connection detail. or
economy. F60 = 1 hour fire protection paint system (2000 microns)
c) Special coatings:
– hot dip galvanised coating (90-100 microns)
– Multicoat: hot dip galvanised coating, plus one layer special topcoat
(excellent for highly aggressive corrosive environments)

Quality Certification
ISO 9001 audited by TÜV.
Welding procedures and quality is inspected by SLV Duisburg
based upon DIN 18800-7.
Lindab Butler complies with the quality requirements of EN 729-2.

Lindab Butler buildings have been tested by our research specialists and
DUISBURG
approved by building authorities around the world. GmbH
Anerkannte Ausbildungs-, Prüf-, Überwachungs-
und Zertifizierungsstelle
Akkredititerte Prüflaboratorien
Typical corner detail at extendable Endwall. Fully engineered framed openings for windows and doors
with countersunk bolts. Lindab Butler reserves the right to alter the above specifications without prior
notice.

Das könnte Ihnen auch gefallen