Sie sind auf Seite 1von 28

C I R C U L AT I N G

S E R I E

P U M P
S C R

C I R C U L AT I N G P U M P 2 0 0 7

Technical Characteristics.
The technical data and characteristics stated in this General Catalogue are not binding. SPERONI spa
reserves the right to make modifications without notice. Therefore weights, dimensions, performances
and any other stated issues are indicative only and not binding. Anyway for any technical details you
must require an up-to-date product technical card.
Competent Court.
In case of any dispute the competent Court will be one of Reggio Emilia even if the payment is by bill
of exchange.

Revisione 1 - 02/2007

INDEX
Pumping Technology

4-5

SCR

6-7

SCRE

8-9

SCRS

10 - 11

SCRF 40

13

SCRF 50

14

SCRF 65

15

SCRF 80

16

SCRFE 40

18

SCRFE 50

19

SCRFD 40

21

SCRFD 50

22

SCRFD 65

23

SCRFD 80

24

SCRFED 40

26

SCRFED 50

27

PUMPING TECHNOLOGY

Production program of the SPERONI Company


The production program of the SPERONI Company comprises pumps of forced circulation of hot
and cold operating in heating systems.
Pumps with the rotor operating in liquid
In pumps with the rotor operating in wet conditions, the rotor is immersed in liquid and
constitutes an element of electric motor.
The sleeve sealing the motor is made from high quality stainless steel and protects the stator of
the motor against flooding by liquid. The pump shaft is made from material resistant to corrosion,
featuring ceramic/graphite bearings. The pump has static sealing. Liquid forced through the pump
fulfills the following two functions: cools the pump and decreases friction in bearings.
Pumps with the rotor operating in wet conditions operate without noise and do not require
expenses to maintain them in the condition of technical efficiency. The group of pumps with the
rotor operating in wet conditions includes pumps with three rotational speeds, selected with
the use of U type switch as well as UE type pipes with electronic control.

Selection of proper type of pump


Selection of pump with three levels of rotational speed
Characteristic features of pumps have been presented in the form of characteristic curves, showing
pressure H, power P and level of pump usage depending on flow Q.
The data related to required flow and pressure drop in the
Figure 1
system / installation are contained in the project
Selection of the pump
documentation. These data can be compared with technical
Pump is completely used
characteristics of pumps, shown in the form of charts; based
(total effectiveness coefficient)
on it we select a proper pump.
PROPER / GOOD
The calculated point R with coordinates Qr and Hr constitutes
the basis for selecting the pump. The pump having three
levels of speed has three characteristics Q-H, for every level
Q-H curve of the pump
of revolutions (see Figure 1). This pump will operate in the
actual working point D. This point constitutes the crossing
between the curve of hydraulic resistance in installation and
R calculation point
the curve Q-H of a given pump.
Qr calculated flow
Hr calculated height of lifting

Selection of electronically regulated pumps


Functioning of electronically regulated pumps has been adjusted to the requirements regarding
usage of heating energy in a year. This average usage is shown on the chart Figure 2 presenting
the profile of seasonal overload.

Heating load

Range of regulation type

Figure 2
Profile of the load

Pump operation field


Max curve Q-H

- angle

Curve Q-Hmin

Number of heating days

- angle specified for every one of pumps

Proper selection of regulated pumps has been shown on figures 3, 4 and 5. (Comparison of pump
characteristics, depending on the design, with actual technical characteristics of a given pump).
4

PUMPING TECHNOLOGY

Calculation point is located in the


proximity of the maximal curve
WRONG
PROPER / GOOD

Calcultion point is located far away


from the maximal curve. The pump is
oversized.

R calculation point

In regulated pumps we have at our disposal the entire operational field of a given pump, contained
between the minimal and maximal functional curve Q-H. Therefore, this type of regulation is
called the stepless thermal regulation. The calculation point R should be located as close as possible
to the maximal functional curve Q-H.
From the figure showing the annual load, we can notice that the heating system with the full
load of thermal power, operates throughout the year only for several days. During the remaining
days the regulation system of electronic pump decreases power usage. In the case of an optimal
control in the system (also with the use of thermostatic valves installed on heating systems) we
are able to save thanks to pumps regulating high amounts of supplied energy. These savings are
shown on Figure 6.
Figure 6
Energy savings with the use of electronic circulating pumps
Characteristic of the system with partial load
Curve Q-H max for electronically regulated pump
I. + II.

- savings field of pressure drops

- calculation point, full load

QR

- full flow

QD

- partial flow

HD=HR

- required height of lifting the pump

Z, Z , Z

- work point, partial load

Characteristic of the system with full load

} Regulated pump

Viscosity of operational media


All hydraulic data and other data contained in the technical catalog, refer to operational media
in the form of water, having kinematic viscosity of 1 mm2/sec.
When in individual pumps there are no separate data regarding operational medium, then in
order to receive normal functionality of the pump we have to guarantee such medium that is
clean, has a standard of normal, liquid form of heating water (according to the requirements of
VDI 2035, specifying hardness and pH value of water), without aggressive and explosive additive,
admixtures of mineral oil as well as hard and fibrous particles.
Kinematic viscosity of water can amount to 10 mm2/sec.
When viscosity of water is in the range between 1 and 10 mm2/sec, then addition of agents
preventing against freezing (e.g. glycol) has no significant influence on operation of the pump.
All rights reserved as regards changes of technical characteristics of SPERONI products without
the necessity of prior notification as well as errors in our technical catalog.

CIRCULATING FOR HEATING AND CONDITIONING

SCR

Applications
The threaded Speroni circulators assure the best technical
and economic performances and they are able to solve all
specific problems in every plants, thanks to their technological
construction innovations.
Single phase circulators are perfect for single or collective
plants of residences, sporting building, hospitals, greenhouses,
etc
Particularly suitable for heating and conditioning plants, for
water circulation in heating system and sanitary warm water
system, with water hardness less than 30F.
Limits of application
- Pressure rating 5,5 bar
- Working max pressure NP 10bar
- Delivery 3,5m/h
- Temperature liquid up to 110 C
- Recommended temperature 65 C
- Continuous service
Motor
- Electric motor
- Isolation class F
- Protection IP 44
Components
- Pumps body in cast iron GG25
- Synthetic Impeller (polymer)
- Shaft in ceramics
- Ball bearing in ceramics
- Trust bearing
- Rotor with Stainless steel housing
- Winding copper wire
- Gasket in EPDM

DIMENSIONS AND WEIGHTS

DN
15
15
20
25
20
25
25
32
20
25
32
20
25
32
25
32

D1
1/2
1/2
3/4
1
3/4
1
1
1 1/4
3/4
1
1 1/4
3/4
1
1 1/4
1
1 1/4

D2
1
1
1 1/4
1 1/2
1 1/4
1 1/2
1 1/2
2
1 1/4
1 1/2
2
1 1/4
1 1/2
2
1 1/2
2

L1
130
130
130
130
130
130
130
130
180
180
180
180
180
180
180
180

B1
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84
84

B2
43
43
43
43
43
43
43
43
43
43
43
43
43
43
43
43

H2
117
117
117
117
117
117
117
117
117
117
117
117
117
117
117
117

Kg
2,3
2,3
2,3
2,3
2,3
2,3
2,6
2,6
2,5
2,5
2,5
2,5
2,5
2,5
2,8
2,8

D2

D1

L1

TYPE
SCR 15/40-130
SCR 15/60-130
SCR 20/40-130
SCR 25/40-130
SCR 20/60-130
SCR 25/60-130
SCR 25/80-130
SCR 32/80-130
SCR 20/40-180
SCR 25/40-180
SCR 32/40-180
SCR 20/60-180
SCR 25/60-180
SCR 32/60-180
SCR 25/80-180
SCR 32/80-180

B1

B2

H2

SCR
SCR 15-20-25-32/60

SCR 15-20-25-32/40

Type

DN

SCR 15/40-130

15

SCR 15/60-130

15

SCR 20/40-130

20

SCR 25/40-130

25

SCR 20/60-130

20

SCR 25/60-130

25

SCR 25/80-130

25

SCR 32/80-130

32

SCR 20/40-180

20

SCR 25/40-180

25

SCR 32/40-180

32

SCR 20/60-180

20

SCR 25/60-180

25

SCR 32/60-180

32

SCR 25/80-180

25

SCR 32/80-180

32

Pos.

(min-1)

P1 (W)

1x230 V
(A)

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

1315
1723
2456
1080
1396
1980
1315
1723
2456
1315
1723
2456
1080
1396
1980
1080
1396
1980
1080
1396
1980
1080
1396
1980
1315
1723
2456
1315
1723
2456
1315
1723
2456
1080
1396
1980
1080
1396
1980
1080
1396
1980
1080
1396
1980
1080
1396
1980

39
60
69
39
62
80
39
60
69
39
60
69
39
62
80
39
62
80
122
158
172
122
158
172
39
60
69
39
60
69
39
60
69
69
62
80
39
62
80
39
62
80
122
158
172
122
158
172

0,17
0,26
0,30
0,17
0,27
0,35
0,17
0,26
0,30
0,17
0,26
0,30
0,17
0,27
0,35
0,17
0,27
0,35
0,53
0,69
0,75
0,53
0,69
0,75
0,17
0,26
0,30
0,17
0,26
0,30
0,17
0,26
0,30
0,17
0,26
0,30
0,17
0,27
0,35
0,17
0,27
0,35
0,53
0,69
0,75
0,53
0,69
0,75

SCR 25-32/80

10
8
6
4
2

ACCESSORIES
Set connections circulators 1/2 SCR 15
Set connections circulators 3/4 SCR 20
Set connections circulators 1 SCR 25
Set connections circulators 1 1/4 SCR 32
7

CIRCULATING FOR HEATING AND CONDITIONING


ELECTRONIC

SCRE

Applications
The threaded Speroni circulators assure the best technical
and economic
performances and they are able to solve all specific problems
in every plants, thanks to their technological construction
innovations.
The electronic circulators allow the automatic regulation of
the pump, according to the applications of the plant; this
is allow a considerable save of energy, the elimination of
the noisiness thanks to thermostatic valves and accessories
and in the improvement of the plant control.
Single phase circulators are perfect for single or collective
plants of residences, sporting building, hospitals, greenhouses,
etc
Particularly suitable for heating and conditioning plants, for
water circulation in heating system and sanitary warm water
system, with water hardness less than 30F.
Limits of application
- Pressure rating 5,5 bar
- Working max pressure NP 10bar
- Delivery 3,5m/h
- Temperature liquid up to 110 C
- Recommended temperature 65 C
- Continuous service
Motor
- Electric motor
- Isolation class F
- Protection IP 44
Components
- Pumps body in cast iron GG25
- Synthetic Impeller (polymer)
- Shaft in ceramics
- Ball bearing in ceramics
- Trust bearing
- Rotor with Stainless steel housing
- Winding copper wire
- Gasket in EPDM

DIMENSIONS AND WEIGHTS


TYPE

DN

D1

D2

L1

B1

B2

H2

Kg

SCRE 15/40-130

15

1/2

130

89

43

117

2,3

SCRE 15/60-130

15

1/2

130

89

43

117

2,3

SCRE 25/40-130

25

1 1/2

130

89

43

117

2,3

SCRE 25/60-130

25

1 1/2

130

89

43

117

2,3

SCRE 25/40-180

25

1 1/2

180

89

43

117

2,5

SCRE 25/60-180

25

1 1/2

180

89

43

117

2,5

SCRE 32/40-180

32

1 1/4

180

89

43

117

2,5

SCRE 32/60-180

32

1 1/4

180

89

43

117

2,5

D2

D1

L1

B1

B2

H2

SCRE
SCRE 15-25-32/40

SCRE 15-25-32/60

POWER CURRENT POWER CURRENT


P1 min (A) min P1 max (A) max

Type

DN

SCRE 15/40-130

15

31

0,12

68

0,33

SCRE 15/60-130

15

37

0,16

86

0,37

SCRE 25/40-130

25

31

0,12

68

0,33

SCRE 25/60-130

25

37

0,16

86

0,37

SCRE 25/40-180

25

31

0,12

68

0,33

SCRE 25/60-180

25

37

0,16

86

0,37

SCRE 32/40-180

32

31

0,12

68

0,33

SCRE 32/60-180

32

37

0,16

86

0,37

ACCESSORIES
Set connections circulators 1/2 SCR 15

Set connections circulators 1 SCR 25

Set connections circulators 1 1/4 SCR 32


9

CIRCULATING FOR SANITARY WARM WATER

SCRS

Applications
The SPERONI SCRS circulators for sanitary warm water are
conceived for the water circulation insisde the distributing
system.
The technical adopted solutions allow the solving of specific
plant problems without changing the water quality.
Limits of application
- Pressure rating 5,5 bar
- Working max pressure NP 10bar
- Delivery 3,5m/h
- Temperature liquid up to 110 C
- Recommended temperature 65 C
- Continuous service
Motor
- Electric motor
- Isolation class F
- Protection IP 44
Components
- Pumps body in bronze
- Synthetic Impeller (polymer)
- Shaft in ceramics
- Ball bearing in ceramics
- Trust bearing
- Rotor with Stainless steel housing
- Winding copper wire
- Gasket in EPDM

DIMENSIONS AND WEIGHTS


DN

D1

D2

L1

B1

B2

H2

Kg

SCRS 20/40-110

20

3/4

1 1/4

110

84

43

117

2,3

SCRS 20/60-110

20

3/4

1 1/4

110

84

43

117

2,3

SCRS 25/40-110

25

1 1/2

110

84

43

117

2,3

SCRS 25/60-110

25

1 1/2

110

84

43

117

2,3

SCRS 20/40-130

20

3/4

1 1/4

130

84

43

117

2,4

SCRS 20/60-130

20

3/4

1 1/4

130

84

43

117

2,4

SCRS 25/40-130

25

1 1/2

130

84

43

117

2,4

SCRS 25/60-130

25

1 1/2

130

84

43

117

2,4

10

D2

D1

L1

TYPE

B1

B2

H2

SCRS
SCRS 20-25/60

SCRS 20-25/40

Type

DN

SCRS 20/40-110

20

SCRS 20/60-110

20

SCRS 25/40-110

25

SCRS 25/60-110

25

SCRS 20/40-130

20

SCRS 20/60-130

20

SCRS 25/40-130

25

SCRS 25/60-130

25

Pos.

(min-1)

P1 (W)

1x230 V
(A)

1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3

1315
1723
2456
1080
1396
1980
1315
1723
2456
1080
1396
1980
1315
1723
2456
1080
1396
1980
1315
1723
2456
1080
1396
1980

39
60
69
39
62
80
39
60
69
39
62
80
39
60
69
39
62
80
39
60
69
39
62
80

0,17
0,26
0,30
0,17
0,27
0,35
0,17
0,26
0,30
0,17
0,27
0,35
0,17
0,26
0,30
0,17
0,27
0,35
0,17
0,26
0,30
0,17
0,27
0,35

ACCESSORIES
Set raccordi circolatore bronzo SCRS 15 1/2 x1

Set raccordi circolatore bronzo SCRS 20 3/4 x1 1/4

Set raccordi circolatore bronzo SCRS 25 1 x1 1/2


11

THREE SPEEDS THREE PHASE CIRCULATING PUMP

SCRF

Applications
The SPERONI SCRF circulators for clean liquids,
without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required.
Limits of application
- Liquid temperature from -10 C to +120 C
(in short-time duty up to + 140 C).
- Ambient temperature up to 40 C.
- Maximum glycol quantity: 50%
(Mixture with more than 20% glycol content require
recheking of the pumping data).
- Maximum permissible working pressure 6/10 bar.
Motor
- 2/4 pole induction motor, 50 Hz.
- Three adjustable speeds.
- SCRF: three-phase 230V or 400 V.
- Insulation class F.
- Protection IP 43.
Components
- Pump casing Cast iron
- Impeller Stainless steel
- Shaft Stainless steel

SCRF
SC

RF

RF

SC

50

20

20

/1
SC
RF

SC

40
/6
0

12

RF

40

/4

RF

/1

40
SC

SC

RF

50

/6

SCR

65

/1

SC

20

SCR

F 50
/4

SCR

F6

5/6

RF

F 80
/60

SCR

SCR
F6
5/4

F8
0/4
0

80

/12

SCRF 40

SCRF 40/60

SCRF 40/40

SCRF 40/120

DIMENSIONS AND WEIGHTS


TYPE

DN

N
Pole
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

SCRF 40-40/250

40

3
2
1

1440
1200
660

240
160
100

0,76
0,24
0,11

17,0

SCRF 40-60/250

40

3
2
1

2790
2240
1440

320
240
140

0,74
0,36
0,18

17,5

40

3
2
1

2820
2200
1250

560
400
220

1,16
0,64
0,26

SCRF 40-120/250

65

198

R 1/4

250

R 1/4
153

92

19,0
13

SCRF 50
SCRF 50/60

SCRF 50/40

SCRF 50/120

DIMENSIONS AND WEIGHTS


TYPE

DN

N
Pole
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

SCRF 50-40/280

50

3
2
1

1450
1220
620

340
240
120

1,05
0,44
0,22

24,0

SCRF 50-60/280

50

3
2
1

1400
1000
560

470
300
100

1,15
0,55
0,20

24,0

50

3
2
1

2800
2330
1270

950
540
265

1,73
1,05
0,46

SCRF 50-120/280
14

70

250

R 1/4

280

R 1/4
160

24,0

113

SCRF 65
SCRF 65/60

SCRF 65/40

SCRF 65/120

DIMENSIONS AND WEIGHTS


TYPE

DN

N
Pole
2 4 Pos. 1/min

P1
(W)

3x
400 V
[A] [kg]

SCRF 65-40/340

65

3
2
1

1430
1150
600

400
260
120

1,10
0,50
0,22

29,0

SCRF 65-60/340

65

3
2
1

1370
950
450

600
360
120

1,25
0,64
0,22

29,0

65

3
2
1

2810
2200
1250

1560
960
460

2,80
1,70
0,84

SCRF 65-120/340

80

252

R 1/4

340

R 1/4
160

123

31,0
15

SCRF 80
SCRF 80/120

SCRF 80/60

DIMENSIONS AND WEIGHTS


TYPE

DN

SCRF 80-60/360

80

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

1350

690

2,20

1000

560

1,10

600

200

0,38

100

257

R 1/4

33,5
360

SCRF 80-120/360

16

80

2800

2200

3,80

2160

1400

2,40

1200

550

1,05

R 1/4

34,5

160

130

THREE SPEEDS SINGLE PHASE CIRCULATING PUMP

SCRFE

Applications
The SPERONI SCRFE circulators for clean liquids,
without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required.
Limits of application
- Liquid temperature from -10 C to +120 C
(in short-time duty up to + 140 C).
- Ambient temperature up to 40 C.
- Maximum glycol quantity: 50%
(Mixture with more than 20% glycol content require
recheking of the pumping data).
- Maximum permissible working pressure 6/10 bar.
Motor
- 2/4 pole induction motor, 50 Hz.
- Three adjustable speeds.
- SCRFE: single-phase 230 V.
- Insulation class F.
- Protection IP 43.
Components
- Pump casing Cast iron
- Impeller Stainless steel
- Shaft Stainless steel

SCRFE

SC

SCR

FE 4
0/6

RF

40

/1

SC

20

RF

SCR

E5
0

/12

FE 5
0/60

17

SCRFE 40
SCRFE 40/120

SCRFE 40/60

DIMENSIONS AND WEIGHTS


TYPE

DN

SCRFE 40-60/250

SCRFE 40-120/250

18

40

40

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

2690

285

1,20

2360

245

1,18

1820

225

1,15

2750

550

2,35

2100

475

2,30

1270

355

1,85

65

198

R 1/4

17,5
250

R 1/4

19,0

153

92

SCRFE 50
SCRFE 50/60

SCRFE 50/120

DIMENSIONS AND WEIGHTS


TYPE

DN

SCRFE 50-60/280

50

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

1260

415

1,8

1030

300

1,3

740

230

1,0

70

250

R 1/4

24,5
280

SCRFE 50-120/280

50

2720

830

3,6

1870

480

2,1

1450

390

1,7

R 1/4

24,5

160

113

19

THREE SPEEDS SINGLE PHASE


CIRCULATING TWIN PUMP

SCRFD

Applications
The SPERONI SCRFD circulators for clean liquids,
without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required.
Limits of application
- Liquid temperature from -10 C to +120 C
(in short-time duty up to + 140 C).
- Ambient temperature up to 40 C.
- Maximum glycol quantity: 50%
(Mixture with more than 20% glycol content
require recheking of the pumping data).
- Maximum permissible working
pressure 6/10 bar.
Motor
- 2/4 pole induction motor, 50 Hz.
- Three adjustable speeds.
- SCRFD: three-phase 230V or 400 V.
- Insulation class F.
- Protection IP 43.
Components
- Pump casing Cast iron
- Impeller Stainless steel
- Shaft Stainless steel

SCRFD
SC
SC

RF

RF

50

40

/1

SC

/1

20

RF

65

20

SC

SC

20

RF

RF

40

SC

/6

D4
0/4

RF

D5
0/6

SCR

FD

SC
0

50/

RF

FD

RFD

20

SCRF

D6
5/6

SCR
40

SC
/1

80/

D 80/
60

65/

SCRF

40

D 80/
40

120

SCRFD 40

SCRFD 40/60

SCRFD 40/40

SCRFD 40/120

DIMENSIONS AND WEIGHTS


TYPE

DN
SCRFD 40-40/250

40

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

3
2
1

1440
1200
660

240
160
100

0,76
0,24
0,11

34,0

346
R 1/4

62

198

153

SCRFD 40-60/250

40

3
2
1

2790
2240
1440

320
240
140

0,74
0,36
0,18

35,0

SCRFD 40-120/250

40

3
2
1

2820
2200
1250

560
400
220

1,16
0,64
0,26

35,0

250

110

21

SCRFD 50
SCRFD 50/40

SCRFD 50/60

SCRFD 50/120

DIMENSIONS AND WEIGHTS


TYPE

DN
SCRFD 50-40/280

50

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

3
2
1

1450
1220
620

340
240
120

1,05
0,44
0,22

44,0

70

160

SCRFD 50-60/280

50

3
2
1

1400
1000
560

470
300
100

1,15
0,55
0,20

44,0

SCRFD 50-120/280

50

3
2
1

2800
2330
1270

950
540
265

1,73
1,05
0,46

44,0

22

400
R 1/4

280

121

250

SCRFD 65
SCRFD 65/40

SCRFD 65/60

SCRFD 65/120

DIMENSIONS AND WEIGHTS


TYPE

DN
SCRFD 65-40/340

65

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

3
2
1

1430
1150
600

400
160
120

1,10
0,50
0,22

49,0

450
R 1/4

80

252

160

SCRFD 65-60/340

65

3
2
1

1370
950
450

600
360
120

1,25
0,64
0,22

49,0

SCRFD 65-120/340

65

3
2
1

2810
2200
1250

1560
960
460

2,80
1,70
0,84

54,0

340

141

23

SCRFD 80
SCRFD 80/120

SCRFD 80/60

DIMENSIONS AND WEIGHTS


TYPE

DN

SCRFD 80-60/360

80

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

1350

960

2,20

1000

560

1,10

600

200

0,38

60,0

470
R 1/4

160
360

SCRFD 80-120/360

24

80

2800

2200

3,80

2160

1400

2,40

1200

550

1,05

95

146

62,0

257

THREE SPEEDS SINGLE PHASE


CIRCULATING TWIN PUMP

SCRFED

Applications
The SPERONI SCRFD circulators for clean liquids,
without abrasives, which are non-aggressive
for the pump materials (contents of solids up to 0.2%).
For heating, conditioning, cooling and circulation plants.
For civil and industrial applications.
When low noise operation is required.
Limits of application
- Liquid temperature from -10 C to +120 C
(in short-time duty up to + 140 C).
- Ambient temperature up to 40 C.
- Maximum glycol quantity: 50%
(Mixture with more than 20% glycol content
require recheking of the pumping data).
- Maximum permissible working
pressure 6/10 bar.
Motor
- 2/4 pole induction motor, 50 Hz.
- Three adjustable speeds.
- SCRFED: single-phase 230V.
- Insulation class F.
- Protection IP 43.
Components
- Pump casing Cast iron
- Impeller Stainless steel
- Shaft Stainless steel

SCRFED

SCR

SC
FED

40/

60

RF

ED

40

/1

SC

20

SCRF

ED 5
0/6

RF

ED

50

/12

25

SCRFED 40
SCRFED 40/60

SCRFED 40/120

DIMENSIONS AND WEIGHTS


TYPE

DN

SCRFED 40-60/250

40

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

2690

285

1,20

2360

245

1,18

1820

225

1,15

35,0

346
R 1/4

153
250

SCRFED 40-120/250 40

26

2755

550

2,35

2100

475

2,30

1270

355

1,85

62

110

35,0

198

SCRFED 50
SCRFED 50/60

SCRFED 50/120

DIMENSIONS AND WEIGHTS


TYPE

DN

SCRFED 50-60/280

50

3x
400 V
[A] [kg]

N
Pole
2 4 Pos. 1/min

P1
(W)

1260

415

1,8

1030

300

1,3

740

230

1,0

44,0

400
R 1/4

SCRFED 50-120/280 50

2720

830

3,6

1870

480

2,1

1450

390

1,7

250

160
280

70

121

44,0

27

Revisione 01 - 02/2007

42024 Castelnovo di Sotto (Reggio Emilia) - Italy - Via S. Biagio, 59


tel. +39.0522.487011 fax +39.0522 487019 - www.speroni.it speroni@speroni.it

Das könnte Ihnen auch gefallen