High efficiency heat recovery unit
Energy efficient fan motors with modern EC technology
Operation from user friendly control panel(s), type CD with LCD-display
Separate setting of supply and extract airflow
Changes automatically to summer operation with no heat recovery
Automatic defrosting
Modbus communication via RS-485
White painted model with EC fans, flexible control functions and modern control
panel, designed for installation on the floor in dwellings with ventilated area up to
apx. 600 m2.
The SAVE VTC 700 is designed for installation on floor, in laundry room, storeroom.
The unit is double skinned, fully insulated and with complete control functions, high
efficiency counterflow heat exchanger and filters. Energy efficient fans with EC
motors will reduce energy consumption for transportation of ventilation air by apx. 50
% compared to traditional AC motors. Modern technology gives low SFP factor
(Specific Fan Power).
The unit will automatically alternate between normal operation with heat recovery
and summer operation without heat recovery. This solution will also automatically
recover chilled indoor air (from cooling).
Airflow and supply air temperature can be set from one or more CD control panels. Symbol and text in the display will indicate chosen settings; reheater operating, summer operation and need for filter change. Commissioning of airflow on supply and extract, on each step, is set from the control
panel. Timer-function for automatic change between day and night operation (installations in commercial buildings) is integrated. Alarm signal will
indicate possible malfunctions.
The CD panel also has a user level for authorized installers and service personnel. The CD panel is connected to the unit by means of cable with
quick connectors (modular plugs), alternatively via 4-pole terminal block.
The SAVE VTC 700 is provided with outlet for control of external hot water battery and inlets prepared for demand controlled ventilation from
external sensors, f. inst. CO2, presence or humidity sensor (potential free contact).
The unit has an automatic defrost function that can be chosen in 5 different modes depending on the indoor environment as well as the outdoor
conditions.
If the unit is to operate for long periods when the outside temperature is below -20, the use of a preheater such as the CB is recommended.
The VTC 700 can be supplemented with a re-heater battery
G4 filters are delivered as standard. F7 and M5 are availabe as accessories.

Technical parameters
Voltage
Frequency
Phase

230

50

Hz

Input power, fan motor(s) (for each motor)

2 x 168

Recommended fuse

10

Enclosure class

24

IP

162

kg

Weight
Filter, supply air

G4 (Standard)

Filter, extract air

G4 (Standard)

Performance
Diagrams
Supply

Name:SAVEVTC700R
SAVEVTC700R
SAVEVTC700R|Itemno.:2173
2173
2173|Version:FilterF7GFG4
FilterF7GFG4
Documenttype:Productcard
Productcard
Productcard|Documentdate:20151012
20151012
20151012|Generatedby:Onlinecatalogue
Onlinecatalogue

Extract

1/5

Selection
Unit

Supply

Extract

Working air flow

725

725 m/h

Working air pressure

100

100 Pa

Power

133

109 W

Speed

2282

SFP (clean filters)

2126 r.p.m.
1.21

Supply air temperature

kW/m/s

20

Sound power level

63

125

250

500

1k

2k

4k

8k

Tot

Supply

dB(A)

46

52

59

59

62

63

54

50

68

Outdoor

dB(A)

35

40

51

43

40

36

28

22

53

Exhaust

dB(A)

40

49

62

60

60

62

53

54

68

Extract

dB(A)

35

41

47

42

44

39

25

22

50

Surrounding

dB(A)

25

36

45

41

42

41

35

30

49

Heat recovery

Supply

Extract

Inlet air temperature

-6

22 C

Outlet air temperature

20

6 C

Inlet air humidity

90

55 %

Outlet air humidity

14

92 %

Air pressure drop

60

76 Pa

Condensate

0,03

l/min

Transferred power

6.27

kW

Temperature efficiency

92

Dry efficiency according to EN 308

83

Exchanger type

Counter flow

calculated at outdoor air +5C, extract air +25C and 27% RH

Dimensions

Name:SAVEVTC700R
SAVEVTC700R
SAVEVTC700R|Itemno.:2173
2173
2173|Version:FilterF7GFG4
FilterF7GFG4
Documenttype:Productcard
Productcard
Productcard|Documentdate:20151012
20151012
20151012|Generatedby:Onlinecatalogue
Onlinecatalogue

2/5

Supply air

Exhaust air

Outdoor air
Extract air

Wiring
Wiring diagram
VTC_700_WD_207582_EN_(A005).pdf (476,42kB)
Scheme

Accessories
Electric accessories
Humidity Sensor Wireless (25127)
Input Module Wireless (25128)
CD Control panel 3 (208175)
CE/CD-diverting plug 4pin (37367)
CEC Cable w/plug 12m (24782)
CEC Cable w/plug 6m (24783)
CO2 Sensor Wireless (25126)
EFD 250 Damper + LF230 motor (6748)
F-T120 Timer frame (5137)
PSS48 Transformer 24V (204385)
Reheater VTC 700 R (2738)
RS485 Gateway Wireless (25130)
RVAZ4 24A Actuator 0-10V (9862)
SmartDial (25129)
TG-K360 Duct sensor 0-60C (4846)
X-Pressure guard w. pitot tube (14369)
CEC Cable w/plug 15m (306594)
Name:SAVEVTC700R
SAVEVTC700R
SAVEVTC700R|Itemno.:2173
2173
2173|Version:FilterF7GFG4
FilterF7GFG4
Documenttype:Productcard
Productcard
Productcard|Documentdate:20151012
20151012
20151012|Generatedby:Onlinecatalogue
Onlinecatalogue

3/5

JP Junction plug for cable (12428)


T 120 Timer (5165)
TG-A130 Surface sensor 0-30C (5159)

Accessories
BFVTC 700 F7 (207470)
Connectduct 250/1,0 M/F (2561)
CVVX 250 Combi grille, black (8498)
CWK 250-3-2,5 Duct cooler,circ (30024)
FK 250 Fast clamp (1612)
LDC 250-600 Silencer (51200)
LDC 250-900 Silencer (5196)
MPVTC 700 F7 (207472)
MPVTC 700 G4 (207469)
MPVTC 700 M5 (207471)
VBC 250-2 Water heating batt (5460)
VBC 250-3 Water heating batt (9843)
X-MRZ 250 CH Round Damper (312144)
ZTR 15-1,6 valve 3-way (9673)
ZTV 15-1,6 2-way valve (9824)
Flex-8-90-125F-REV (25471)
Flex-8-90-125U-REV (25470)
Flex-8-90-160F-REV (25473)
Flex-8-90-160U-REV (25472)
Flex-Blanco RAL 9016 (25474)
Flero-090 (69702)
Kabelbinder 9.0x550mm schwarz (27690)
KSR 90 (27680)
RDR-80/15-50m/h (37293)
Flero-Muffe 090 (68008)
Flero-Dichtung 090 (68011)
Hella-A-2-600-CH-RAL 9016 (27420)
Hella-A-2-400-CH-RAL 9016 (19642)
Hella-A-600-CH-RAL 9016 (19574)
Hella-A-400-CH-RAL 9016 (18125)
PB-Hella-A-2-400-CH (25331)
PB-Hella-A-2-600-CH (26393)
PB-Hella-A-400-CH (14918)
PB-Hella-A-600-CH (18775)
LGS-PRAG RAL9016 (49971)
LGS-BERN RAL9016 (27419)
PB-LGS (49970)
LGR-PRAG RAL9016 (27221)
LGW-Bern (63287)
PB-LGR (27220)

Specification text
Wohnungslftungsgert mit Wrmerckgewinnung.
Montage stehend.
Anschlussfertig mit Kabel und Schukostecker.
Komplett mit zwei Hochleistungslaufrder mit energiesparenden EC-Motoren, einseitig saugend.
Mit vier vertikal oben liegenden Anschlssen (Muffe) fr Lftungsrohr DN 250 ausgestattet.
Gehuse aus doppelschaligen verzinktem Stahlblech, wei lackiert (RAL 9010), allseitig isoliert mit 30 mm Mineralwolle zur Wrme- und
Schalldmmung.
Die komplette Front ist fr Reinigung und Wartungsarbeiten abnehmbar.
Wrmerckgewinnung mittels Gegenstromwrmebertrager aus Aluminium, Wrmebereitstellungsgrad bis ber 85%, Frostschutz integriert,
Kondensatablauf vorhanden, Kondensatanschluss erforderlich.
Automatischer Sommer Bypass und automatische Rckgewinnung von Klteleistung im Sommer.
Zwei Hochleistungslaufrder aus Kunststoff, rckwrtsgekrmmt.
Laufrder nach VDI 2060, Auswuchtgte G 6.3, in zwei Ebenen dynamisch gewuchtet.
Ventilatormodule auf Gummischwingungsdmpfer gegen Krperschall entkoppelt.
Energiesparenden, hocheffizienten EC-Auenlufermotor, schwingungsfrei aufgehngt.
Khlung durch Anordnung des Motors innerhalb des Luftstromes.
Motorschutz durch integrierte Motorelektronik, zustzliches Motorschutzschaltgert wird hierzu nicht bentigt.
Steckverbindungen an allen elektr. Bauteilen zur Vereinfachung von Wartungsarbeiten.
Ventilatoren fr 3-stufigen Betrieb, wobei die Luftmenge in jeder Stufe direkt eingegeben werden kann.
Die Gleichstromventilatoren sind volumenstrombalance geregelt und knnen zustzlich untereinander plus/minus 20% ausgeregelt werden.
Zwei Kassettenfilter G4 fr Zu- und Abluft serienmig eingebaut.
Die Filter sind vor dem Wrmetauscher angeordnet, auf Schienen gefhrt und mit Dichtungen ausgestattet.
Filterberwachung mittels Filterstandzeit, einstellbar von 6-15 Monaten.

Name:SAVEVTC700R
SAVEVTC700R
SAVEVTC700R|Itemno.:2173
2173
2173|Version:FilterF7GFG4
FilterF7GFG4
Documenttype:Productcard
Productcard
Productcard|Documentdate:20151012
20151012
20151012|Generatedby:Onlinecatalogue
Onlinecatalogue

4/5

Die Zuluft ist rechts angeordnet.


Regelung:
Die Bedieneinheit CD mit LCD-Display sowie 6 m Verbindungskabel sind im Lieferumfang inklusive.
Ein Anschluss von zustzlich bis zu zwei Bedieneinheiten Typ CD 2 (Zubehr) ist mglich.
An der Bedieneinheit kann die Zulufttemperatur (Schaltpunkt fr die Sommerfunktion) von ca. 15-19C und die Drehzahl der Ventilatoren eingestellt
werden.
Ebenfalls als Zubehr kann ein Wasserheiz- oder -khlregister angeschlossen und ber einen 0-10V Ausgang geregelt werden.
(24V Versorgung fr den Stellantrieb bauseits).
Ein Nachheizregister (Zubehr) kann aktiviert werden und schaltet zu, sobald die eingestellte Zulufttemperatur nach dem Wrmebertrager
unterschritten wird.
ber einen Sammelstrmeldeausgang knnen Strungen extern weitergegeben werden.
Auf dem Display werden die Strungen im Klartext angezeigt.
ber digitale Eingnge knnen die Drehzahlstufen von extern angewhlt werden.
Ebenfalls kann eine Differenzdruckberwachungseinrichtung fr die Kombination mit einem Holzofen aufgeklemmt werden.
Bei Abschaltung geht der Zuluftventilator auf max. Drehzahl und der Abluftventilator auf min. Drehzahl.
Somit wirkt das Lftungsgert aktiv dem Unterdruck entgegen.
Es ist elektronisch gesichert, dass immer nur beide Ventilatoren laufen bzw. beide Ventilatoren stehen.
Die Zertifizierung nach Richtlinien des Passivhaus Instituts ist beantragt.

Abmessungen:
Breite: 1170 mm
Tiefe: 860 mm
Hhe: 1214 mm
Techn. Daten:
Luftleistung: 830 m/h
Bei dp: 150 Pa
Wrmebereitstellungsgrad: 85 %
Nennleistung/Motoren: je 168 W
Absicherung: 10 A
Gewicht: 150 kg

CAD drawing
VTC 700 R.dxf (837,33kB)

Documentation
VTC_700_Inst_and_service_207580_CE_GB_A003.pdf (4,84MB)
VTC_700_User_manual_207581_GB_A002.pdf (821,37kB)
Quick_Guide 205821.pdf (80,62kB)
E80981_SAVE_VTC_300_700_SE.pdf (1,91MB)
Nvod_SAVE_VTC_700_2014.pdf (1,38MB)
Bvd Bostadsaggregat SAVE VTC300, VTC700.pdf (54,25kB)
Pipojen_SAVE_VTC_700.pdf (161,96kB)
Modbus for Residential units_D24810_User_manual (A005).pdf (263,77kB)
CD panel Instruction for wall mounting 206858 GB_SE.pdf (221,37kB)
SAVE_VTC_700_Changing_the_bypass_damper_209246-en_GB (A002).pdf (8,23MB)
Passive House Certificate SAVE VTC 700.pdf (254,24kB)

Name:SAVEVTC700R
SAVEVTC700R
SAVEVTC700R|Itemno.:2173
2173
2173|Version:FilterF7GFG4
FilterF7GFG4
Documenttype:Productcard
Productcard
Productcard|Documentdate:20151012
20151012
20151012|Generatedby:Onlinecatalogue
Onlinecatalogue

5/5

Das könnte Ihnen auch gefallen