Sie sind auf Seite 1von 11

UA5000

Operation Manual - PVU Volume

Contents

Contents
6 Frame Configuration .................................................................................................................6-1
6.1 Overview of Frames ......................................................................................................................................6-2
6.2 Frame Configuration .....................................................................................................................................6-3
6.2.1 Adding a Frame....................................................................................................................................6-3
6.2.2 Querying the Information of a Frame ..................................................................................................6-4
6.2.3 Adding an Inter-frame Connection.......................................................................................................6-4
6.2.4 Querying the Information about an Inter-frame Connection................................................................6-4
6.2.5 Deleting an Inter-frame Connection.....................................................................................................6-5
6.2.6 Deleting a Frame..................................................................................................................................6-5
6.3 Configuration Example .................................................................................................................................6-5
6.3.1 Networking ..........................................................................................................................................6-6
6.3.2 Adding the Frames ...............................................................................................................................6-6

Issue 02 (2007-03-20)

Huawei Technologies Proprietary

UA5000
Operation Manual - PVU Volume

Figures

Figures
Figure 6-1 Sample connection among the master, slave and extended frames...................................................6-6

ii

Huawei Technologies Proprietary

Issue 02 (2007-03-20)

UA5000
Operation Manual - PVU Volume

Tables

Tables
Table 6-1 Frames and backplanes.......................................................................................................................6-2
Table 6-2 Commands for configuring a frame....................................................................................................6-2

Issue 02 (2007-03-20)

Huawei Technologies Proprietary

iii

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

Frame Configuration

About This Chapter


The following table lists the contents of this chapter.
Section

Describes

6.1 Overview of Frames

The types of the UA5000 frames and the commands for


configuring a frame

6.2 Frame Configuration

How to configure a frame

6.3 Configuration Example

Example of configuring a frame

Issue 02 (2007-03-20)

Huawei Technologies Proprietary

6-1

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

6.1 Overview of Frames


There are three types of the UA5000 frames. They are master frame, slave frame and extended
frame.
z

A master frame can be connected with a slave frame and an extended frame to expand the
system capacity.

A slave frame can be connected with an extended frame to expand the system capacity.
The slave frame needs to be added using the frame add command. The slot of the slave
frame is numbered from 0.

An extended frame can be seen as a logical extension of the master frame or the slave
frame it connects. The slots are numbered sequentially with that of the mater frame or the
slave frame.

These three types of frames use different backplanes. See Table 6-1.

Table 6-1 Frames and backplanes


Frame Type

Backplane Type

Frame Alias

Rear-access master frame

HABA

MAIN_HABM_30

Front-access master frame

HABD

MAIN_HAFM_30

Rear-access master frame

HABC

MAIN_HABM_12

Front-access slave frame

HABE

SLAVE_HAFS_32

Front-access extended frame

HABF

Table 6-2 lists the commands for configuring a frame.


Table 6-2 Commands for configuring a frame

6-2

To

Use

In

Add a frame

frame add

Global config mode

Add an inter-frame connection

frame connect

Global config mode

Delete an inter-frame connection

[undo] frame connect

Global config mode

Query the setting of inter-frame


connection

display frame connect

Global config mode

Query the setting of frames

display frame info

Global config mode

Delete a frame

frame delete

Global config mode

Configure frame attributes

frame set

Global config mode

Huawei Technologies Proprietary

Issue 02 (2007-03-20)

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

6.2 Frame Configuration


6.2.1 Adding a Frame
To configure a frame, you need to add it to the system first. To add a frame, use the frame add
command. The frame with PVU card is the master frame, and the frame number is fixed as 0.
For example, to add a master frame whose frame type is MAIN_HAFM_30 (H601HABD), and
add a slave frame whose frame type is SLAVE_HAFS_32 (H602HABE), do as follows:
huawei(config)#frame add
{ frameid<U><0,64> }:0
FrameType:
0 : MAIN_HAFM_30(H601HABD)

1 : MAIN_HAFM_6(H601HABL)

2 : MAIN_HABM_30(H601HABA)

3 : MAIN_HAFM_30(H602HABD)

4 : MAIN_HABM_12(H601HABC)

5 : SLAVE_HAFS_32(H601HABE)

6 : SLAVE_HABS_32(H601HABB)

7 : SLAVE_HABS_30(H601HABA)

8 : SLAVE_HAFS_30(H601HABD)

9 : SLAVE_HAFS_30(H602HABD)

10 : SLAVE_HAFS_32(H602HABE)

11 : RSU_HAFS_30(H601HABD)

12 : RSU_HABS_30(H601HABA)

13 : RSU_HAFS_6(H601HABL)

14 : RSU_HAFS_30(H602HABD)

15 : RSP_19(HCB)

16 : RSP_15(HDB)

17 : RSP_14(HIB)

18 : RSP_12(HFB)

19 : RSP_10(HGB)

20 : RSP_6A(HMB)

21 : RSP_6B(HLB)

22 : UAM_R (HUBM)

23 : UAS_R (HUBS)

24 : UAFM_R(HUBE)

25 : UAFS_R(HUBF)

26 : UABM_R(HUBB)

27 : ONU60A_R(HUBO)

28 : UAFX_R(HUBL)
Please select frame type (0 ~ 28):0
Frame add successfully
huawei(config)#frame add 10
FrameType:
0 : MAIN_HAFM_30(H601HABD)

1 : MAIN_HAFM_6(H601HABL)

2 : MAIN_HABM_30(H601HABA)

3 : MAIN_HAFM_30(H602HABD)

4 : MAIN_HABM_12(H601HABC)

5 : SLAVE_HAFS_32(H601HABE)

6 : SLAVE_HABS_32(H601HABB)

7 : SLAVE_HABS_30(H601HABA)

8 : SLAVE_HAFS_30(H601HABD)

9 : SLAVE_HAFS_30(H602HABD)

10 : SLAVE_HAFS_32(H602HABE)

11 : RSU_HAFS_30(H601HABD)

12 : RSU_HABS_30(H601HABA)

13 : RSU_HAFS_6(H601HABL)

14 : RSU_HAFS_30(H602HABD)

15 : RSP_19(HCB)

16 : RSP_15(HDB)

17 : RSP_14(HIB)

18 : RSP_12(HFB)

19 : RSP_10(HGB)

20 : RSP_6A(HMB)

21 : RSP_6B(HLB)

22 : UAM_R (HUBM)

23 : UAS_R (HUBS)

24 : UAFM_R(HUBE)

25 : UAFS_R(HUBF)

26 : UABM_R(HUBB)

27 : ONU60A_R(HUBO)

28 : UAFX_R(HUBL)
Please select frame type (0 ~ 28):10
Frame add successfully
! FAULT MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame fault
PARAMETERS :FrameID: 1

Issue 02 (2007-03-20)

Huawei Technologies Proprietary

6-3

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

Select correct frame type when adding a frame. Otherwise, the cards in the frame may not function
normally.

A slave frame is in fault state after it is added. You need to configure the inter-frame connection for the
frame to make it work normally.

6.2.2 Querying the Information of a Frame


To query the information of one or all frames, use the display frame info command.
For example, to query the information of all frames, do as follows:
huawei(config)#display frame info
{ desc<K>|ts-information<K> }:
{ info<K>|link<K>|connect<K> }:info
{ <cr>|frameid<U><0,64> }:
Command:
display frame info
---------------------------------------------------------------------------FrameID

FrameType

FrameState

---------------------------------------------------------------------------0

MAIN_HAFM_30(H601HABD)

Normal

RSU_HAFS_30(H602HABD)

Failed

---------------------------------------------------------------------------Total: 2

6.2.3 Adding an Inter-frame Connection


The PVU card provides five 16 Mbit/s HWs to connect slave and extended frames. These HWs
are numbered 16 to 20. HW 16 is for the extended frame of this master frame. HWs 17 and 18
are for the slave frames and their extended frames.
To add an inter-frame connection, use the frame connect command. In the UA5000 PVU, the
master frame is numbered 0 and the slave frames are numbered 18.
For example, to add an inter-frame connection between frame 0 and frame 1, do as follows:
huawei(config)#frame connect
{ upframeid<U><0,64> }:0
{ downframeid<U><0,64> }:1
Add the frame connection successfully
huawei(config)#
! RECOVERY MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame recovery alarm
PARAMETERS :FrameID: 1

6.2.4 Querying the Information about an Inter-frame Connection


To query the information about the inter-frame connection of one or all frames, use the display
frame connect command.
For example, to query the information about the inter-frame connections of all frames, do as
follows:
huawei(config)#display frame connect
{ <cr>|frameid<U><0,64> }:

6-4

Huawei Technologies Proprietary

Issue 02 (2007-03-20)

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

Command:
display frame connect
--------------------------------------------Record

Upper-frame

Lower-frame

---------------------------------------------

6.2.5 Deleting an Inter-frame Connection


To delete an inter-frame connection, use the undo frame connect command.
For example, to delete the link between frame 0 and frame 1, do as follows:
huawei(config)#undo frame connect
{ upframeid<U><0,64> }:0
{ downframeid<U><0,64> }:1
Changing the connection between frames will interrupt services,are you sure to
continue(y/n)[n]:y
Delete the frame connection successfully
! FAULT MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame fault
PARAMETERS :FrameID: 1

6.2.6 Deleting a Frame


To delete a frame, use the frame delete command.
Before deleting a frame, you need to delete all configurations associated with the frame,
including services, line card, environment monitor unit, and inter-frame connections.
For example, to delete frame 1, do as follows:
huawei(config)#frame delete
{ frameid<U><0,64> }:1
Are you sure to delete this frame? (y/n)[n]:y
Frame 1 delete successfully

6.3 Configuration Example


The configuration procedure is as follows:
Step 1 Add a frame.
Step 2 Add an inter-frame connection.
Step 3 Add line cards.
Step 4 Confirm the line cards.
----End

Issue 02 (2007-03-20)

Huawei Technologies Proprietary

6-5

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

6.3.1 Networking
Figure 6-1 shows the connection between the master frame (HABD), the slave frame (HABE)
and the extended frames (HABF).
Figure 6-1 Sample connection among the master, slave and extended frames
PSTN
E1/V5

Extended frame of the master frame

Master frame
PP
VV
UU

D
S
L

D AA
S SS
L L L

D D
S S
L L

D
S
L

AA
SS
L L

HWOUT0
HWOUT1
HWOUT2

H
W
C

HWIN

Slave frame

Extended frame of the slave frame

D D
S S
L L
HWIN

H
W
T

D
S
L

AA
SS
L L

D D
S S
L L

D
S
L

AA
SS
LL

HWIN H
W
T

H
W
T

6.3.2 Adding the Frames


Step 1 Add a master frame, with the frame number of 0, and frame type of MAIN_HAFM_30
(HABD).
huawei(config)#frame add
{ frameid<U><0,64> }:0
FrameType:
0 : MAIN_HAFM_30(H601HABD)

1 : MAIN_HAFM_6(H601HABL)

2 : MAIN_HABM_30(H601HABA)

3 : MAIN_HAFM_30(H602HABD)

4 : MAIN_HABM_12(H601HABC)

5 : SLAVE_HAFS_32(H601HABE)

6 : SLAVE_HABS_32(H601HABB)

7 : SLAVE_HABS_30(H601HABA)

8 : SLAVE_HAFS_30(H601HABD)

9 : SLAVE_HAFS_30(H602HABD)

10 : SLAVE_HAFS_32(H602HABE)

11 : RSU_HAFS_30(H601HABD)

12 : RSU_HABS_30(H601HABA)

13 : RSU_HAFS_6(H601HABL)

14 : RSU_HAFS_30(H602HABD)

15 : RSP_19(HCB)

16 : RSP_15(HDB)

17 : RSP_14(HIB)

18 : RSP_12(HFB)

19 : RSP_10(HGB)

20 : RSP_6A(HMB)

21 : RSP_6B(HLB)

22 : UAM_R (HUBM)

23 : UAS_R (HUBS)

24 : UAFM_R(HUBE)

25 : UAFS_R(HUBF)

26 : UABM_R(HUBB)

27 : ONU60A_R(HUBO)

28 : UAFX_R(HUBL)
Please select frame type (0 ~ 28): 0

6-6

Huawei Technologies Proprietary

Issue 02 (2007-03-20)

UA5000
Operation Manual - PVU Volume

6 Frame Configuration

Frame add successfully

You can use the display board 0 command to query the state of the card in the new frame.
Step 2 Add a slave frame, with the frame type of SLAVE_HAFS_32 (H602HABE).
huawei(config)#frame add
FrameType:
0 : MAIN_HAFM_30(H601HABD)

1 : MAIN_HAFM_6(H601HABL)

2 : MAIN_HABM_30(H601HABA)

3 : MAIN_HAFM_30(H602HABD)

4 : MAIN_HABM_12(H601HABC)

5 : SLAVE_HAFS_32(H601HABE)

6 : SLAVE_HABS_32(H601HABB)

7 : SLAVE_HABS_30(H601HABA)

8 : SLAVE_HAFS_30(H601HABD)

9 : SLAVE_HAFS_30(H602HABD)

10 : SLAVE_HAFS_32(H602HABE)

11 : RSU_HAFS_30(H601HABD)

12 : RSU_HABS_30(H601HABA)

13 : RSU_HAFS_6(H601HABL)

14 : RSU_HAFS_30(H602HABD)

15 : RSP_19(HCB)

16 : RSP_15(HDB)

17 : RSP_14(HIB)

18 : RSP_12(HFB)

19 : RSP_10(HGB)

20 : RSP_6A(HMB)

21 : RSP_6B(HLB)

22 : UAM_R (HUBM)

23 : UAS_R (HUBS)

24 : UAFM_R(HUBE)

25 : UAFS_R(HUBF)

26 : UABM_R(HUBB)

27 : ONU60A_R(HUBO)

28 : UAFX_R(HUBL)
Please select frame type (0 ~ 28):10
Frame add successfully
! FAULT MAJOR 2006-12-25 22:04:14 ALARM NAME :Frame fault
PARAMETERS :FrameID: 1

Step 3 Add an inter-frame connection.


huawei(config)#frame connect 0 1
Add the frame connection successfully

Step 4 Add line cards.


Add line cards for the master, slave and extended frames according to the data planning. The
command used is board add. Following is an example.
huawei(config)#board add 0/14 asl

huawei(config)#board add 0/25 asl

huawei(config)#board add 1/15 asl


huawei(config)#board add 1/25 asl

Step 5 Confirm the line cards.


huawei(config)#board confirm 0
huawei(config)#board confirm 1

----End