MPH: OIL PUMP MOTOR

It is a pump motor used to circulate transformer oil through the radiator. A relay QPH is provided
to ensure the proper functioning of MPH. Whenever the MPH or PH is not functioning properly
this relay QPH will deenergise and trips DJ. A switch HPH is provided to isolated the motor
MPH it has four positions.
HPH position:
0 Both MPH and QPH isolated
1 Both MPH and QPH in service
2 MPH isolated and QPH in service
3 MPH in service and QPH isolated.
QPH is provided in HT2 compartment and HPH is located in switch panel.
Silicon Rectifier Blower Motors: MVSI 1 & 2
Each rectifier block is provided with one blower which is driven by the motors MVSI 1
& 2. These motors are three phase induction motors of 2.2 KW each. These motors of rectifier
blocks are switched on and off by means of HVSI 1.& 2. The cooling of the rectifiers is
monitored by the airflow relay QVSI 1.& 2, the contact of QVSI 1.& 2 are connected in series
and lie in the energizing circuit of Q44. During normal operation this contact are closed. On
failure of blower the air flow relay QVSI 1 & 2 operates (contacts opens) will cause to open DJ.
These motors are starting along with ARNO.
HVSI positions:0 motor and relay not in service
1 motor and relay in service
2 motor isolated and relay in service
3 motor working and relay isolated

MVSL 1: Blower Motor For Smoothening Reactor


This is also a direct motor, which starts along with ARNO. It also operates the blower VSL . A
relay QVSL1 is provided to ensure the proper functioning of MVSL1, and VSL1. Whenever
MVSL, or VSL1 is not functioning properly DJ trips. Switch HVSL1 is provided which is
having 4 positions.
HVSL 1 positions:
0 MVSL1, QVSL1 - Isolated.
1 MVSL1, QVSL1 - in Service
2 MVSL1 isolated, QVSL1 - in service
3 MVSL 1- in Service ,QVSL1 isolated
MVSL1&2 are located in HT2 compartment and HVSL is located in switch panel. This is a
direct motor starts along with ARNO. It cools smoothening reactor No.1 (SL1).

MVSL2: Blower Motor for Smoothening Reactor2


This motor starts along with ARNO. It cools the smoothening reactor SL2. It also operates the
blower VSL2. QVSL2 is provided to check the performance of VSL2 and MVSL2. Whenever
VSL2 or MVSL2 becomes defective QVSL2 will deenergise and trips DJ. A switch HVSL2 is
provided which is having four positions similar to that of HVSL1. It is provided in HT2
compartment RSI2 block.
HVSL2 position:
0 MVSL2, QVSL2 Isolated
1 MVSL2, QVSL2 - in Service
2 MVSL2 isolated, QVSL2 - in service
3 MVSL2- in Service, QVSL2 - isolated
REMOTE CONTROLLED AUX. MOTORS
Main Compressors (MCP1, MCP2, MCP3)
There are 3 compressor motors provided in a loco to build up air pressure for the operation of
pneumatic & braking system. The electromagnetic contactor C101, C102 & C103 are for MCP1,
MCP2 and MCP3 respectively. The switches for these contactors are BLCP and BLCPD. The
switch HCP is located in switch panel and it is having 8 positions to program the compressor as
required.
HCP Main compressor isolating switch:
HCP is having 8 positions namely 0, 1, 2, 3, 12, 23, 13, 123.
Whenever vacuum brake train is operated HCP should be kept in 1 or 2 or 3. While
working in AIR brake HCP should be kept in 1&3 or 1&2 or 2&3 or 1&2&3 position. The
compressors are provided with individual oil sump. The oil level should be with in the minimum
and maximum marks. Whenever any MCP is defective, it can be isolated by HCP. In WAG 5A
locomotives compressor starts working when BLCP is switched ON. But the air pressure is
maintained between 8.5kg/cm and 10 kg/cm by RGCP & VEAD valve. MCP 1, 2 & 3 are
provided in motor chest No1. RGCP is provided in CAB1 center locker 1, VEAD is provided
behind CAB1.
Exhauster Motors MPV1&MPV2:
There are two exhauster motors provided in WAG 5A Electro Magnetic contactors C121 is for
MPV1 and C111 is for MPV2. These contactors are remote controlled by the switches BLPV &
HPV. When BLPV is closed and ZPV on 2 position, contactor C121 closes and MPV1 starts
working. When ZPV in 1 position contactor C111 closes and MPV2 starts working.
ZPV POSITIONS
ZPV

BLPV

HPV

1 Position

C111closes PV2 works

C121 closes PV1works

2 Position

C121 closes PV 1works

C111 closes PV2 works

3 Position

C111 closes PV2 works

PV1 isolated

4 Position

C121 closes PV1 works

PV2 isolated

MPV1 & MPV2 are located behind CAB1. ZPV is located in switch panel. Two types of
exhausters are provided. They are of SLM TYPE & NORTHEY TYPE. SLM type exhauster
is having an oil sump at the bottom with a dipstick for checking oil level. The oil level
should be between minimum and maximum marks. A gear driven lubricating oil pump is
provided to transfer the oil from the sump to the bearings. 4 sight glasses are provided on the
exhausters. To check the oil drops for lubricating the gears and bearings. Minimum 9-12
drop/min should pass thorough the sight glasses. A manual operating handle is also provided
on lubricating pump to check the efficiency of the pump.
In NORTHEY type exhauster there are two oil sumps. One at the bottom and other the
top for lubricating the gears & bearings. The lower sump lubricates the gears by splashing oil and
the upper lubricates the gears by splashing oil and the upper sump lubricates the bearings by
section. Both sumps are provided with dipsticks for checking the oil levels. It should between
min & max marks.
MVRH: Radiator Blower Motor
It is provided to operate the blower VRH for cooling the transformer oil in the radiator and RPS.
It is provided in HT2 compartment. C107 contactor is provided to start and stop the motor.
BLVMT is provided to start and stop the motor. When BLVMT is switched on contactor C107
closes and MVRH starts working. The working of MVRH can be checked from corridor No2. To
monitor the working of VRH, a relay QVRH is provided. A switch HVRH is provided to isolate
QVRH or MVRH whenever MVRH or QVRH is defective. It has four positions.
HVRH switch positions:
0
QVRH & MVRH not in service
1
QVRH & MVRH both in service
2
QVRH in service & MVRH not in service
3
QVRH out of service & MVRH in service
MVMT1 & MVMT2 (TRACTION MOTORS BLOWER MOTORS 1 & 2)
MVMT1 is provided to operate VMT1, which cools TM1, 2&3. MVMT2 is provided to
operate VMT2, which cools TM4, 5 and 6. MVMT1 is provided behind CAB1 & MVMT2 is
behind CAB2. Electro magnetic contactor C105 is for MVMT1, and C 106 is for MVMT2.
These contactors are remote controlled by the switch BLVMT. Relays QVMT1 & QVMT2 are
provided to check the proper functioning of MVMT1 &2. In any case if one of the MVMTs
becomes defective or sluggish in operation, these relays will de-energise and trip DJ. MVMT1 is
having an isolating switch HVMT1 and MVMT2 is having an isolating switch HVMT2. They
are located in switch panel and have 4 positions (0, 1, 2 and 3).
HVMT1 positions
0 MVMT1 and QVMT1 are isolated
1 Both MVMT1 and QVMT1 in service
2 MVMT1 is isolated and QVMT1 is in service
3 MVMT1 is in service and QVMT1 is isolated

HVMT2 positions
0 MVMT2 and QVMT2 are isolated
1 Both MVMT2 and QVMT2 in service
2 MVMT2 is isolated and QVMT2 is in service
3 MVMT2 is in service and QVMT2 is isolated

Sl
No

Auxiliary
Name

Remote
Control
Switch

Contacto
Relay
r

ARNO

BLDJ
BLRDJ

C118

Sl
No

Auxiliary
Name

Remote
Control
Switch

Conta
ctor

QCVAR

Relay

Isolating
Switch

HQCVAR

Switch
Positio
ns

Purpose

0,1

It is a single-phase
induction
motor
while starting and
after picking up
speed it works as
on 3 Induction
Generator.
It
converts
single
phase into 3 phase
and supplies 3 to
all 13 auxiliary
motors.

Switch
Isolating
Position
Switch
s

MPH

Direct

QPH

HPH

0,1,2&3

MVSL1

Direct

QVSL1

HVSL1

0,1,2&3

MVSL2

Direct

QVSL2

HVSL2

0,1,2&3

MVSI1

Direct

QVSI1

HVSI1

0,1,2&3
0,1,2&3

MVSI2

Direct

QVSI2

HVSI2

Purpose
It is a motor for
circulating oil in the
transformer through the
pump PH.
It is a motor for
smoothening
reactor
blower (VSL1) which
supplies air to cool SL
It is a motor for
smoothening
reactor
blower (VSL2) which
supplies air to cool SL2.
It is a motor for rectifier
block Cooling blower
(VSI1) which supplies
air to cool RSI1
It is a motor for Rectifier
block cooling blower
(VSI2) Which supplies
air to cool RSI block 2.

7
8

MCP1
MCP2

MCP3

10

MPV1

11

MPV2

12

MVRH

13
14

C101
C102
BLCP /
BLCPD

BLPV/
HPV
BLVMT

RGCP

HCP

C103
C121

0,1,2,3,
(1-2) (23) (1-3)
& (1,2,3)
1,2,3,4

ZPV

C111

C107

QVRH

HVRH

0,1,2&3

MVMT1

C105

QVMT1

HVMT1

0,1,2 &3

MVMT2

C 106

QVMT2

HVMT2

0,1,2&3

To Build up compressed
air pressure and to store
in main Reservoirs
MR1, MR2, MR3&4 for
pneumatic operations
and brake system.
To create vacuum & to
maintain
for
train
braking operation.
It is a motor for radiator
cooling blower (VRH)
which supplies air to
cool the Tr. oil as well as
RPS1 to RPS6
It is a motor for TM
blower to cool the
traction motors 1,2 & 3
It is a motor for TM
blower to cool TM4 ,
5&6