Sie sind auf Seite 1von 4

Type 1259 Process Pressure Gauge

Solid front safety case


Accuracy complies with ASME B40.1
Grade 2A (0.5% of span)
As-welded Bourdon tube for safety and
longer life
Micrometer adjustable pointer.
Adjustable movement
Ranges: vac to 20,000 psi
Date coded socket to ensure pedigree
Wetted part material printed on dial
Liquid filled case option (Code L)
The Type 1259 process gauge is offered
with an as-welded Bourdon tube to ensure
safety and a long life. Meeting ASME
B40.1, the Type 1259 process gauge has
been engineered to meet marketplace
requirements.
TEMPERATURE LIMITS

Dry
LF
(glycerin)

Ambient
20/200F
(29/93C)
20/150F
(7/66C)

Process
Storage
20/250F 40/250F
(29/121C) (40/121C)
20/200F
0/150F
(7/93C) (18/66C)

Note: Other than discoloration of the dial and hardening of the


gasketing that may occur as ambient or process temperatures
exceeds 150F, non-liquid-filled gauges with standard glass windows, can withstand continuous operating temperatures up to
250F (121C). Liquid-filled gauges can withstand 200F (93C)
but glycerin fill and acrylic window will tend to yellow. Accuracy
at temperatures above or below the reference ambient temperature of 68F (20C) will be affected by approximately .4% per
25F. Gauges with welded joints will withstand 750F (450F
(232C) with silver brazed joints) for short times without rupture, although other parts of the gauge will be destroyed and
calibration will be lost. For continuous use and for process or
ambient temperatures above 250F (121C), a diaphragm seal
or capillary or siphon is recommended.

PRODUCT SPECIFICATIONS
Model Number: 1259
1
Accuracy:
2% full scale (Grade 2A,
ASME B40.100)
Ranges:
Vacuum 20,000 psi
Ring Type:
Cam lock, fiberglass
reinforced thermoplastic
Dial Size:
412 diameter
Case:
Solid front safety
Case Material: Fiberglass reinforced
thermoplastic
Weather
Protection:
Dry Case: IP54
Liquid filled or hermetically
sealed case: IP 65
Window:
Glass
Dial:
Aluminum, white background,
black pressure scale.
Pointer:
Micrometer adjustable
Movement:
Adjustable 300 series ss
Bourdon Tube 316L SS/316L SS (S)(1)
& Socket:
K Monel/Monel (P)(1)
1
Conn. Size:
4, 12 NPT
Conn. Location: Lower
Weight (Lbs.)
2.5 (Dry)
3.5 (Liquid Filled)
PRODUCT OPTIONS
Fill:
Glycerin
Hermetic Seal: XLJ
Flush Mounting
Ring:
X56, X57
Shatter Proof
Glass Window: XSG
Window Acrylic: XPD
(1)

Joints welded

Dimensions
Dia. 5.37
BOLT CIRCLE

3.36
Dia. 5.81

Dia. 5.19

2.63
.24
3X Dia.

3.98

.62
ACROSS FLATS
1/2 OR 1/4
NPT

BULLETIN PR-1259

All specifications are subject to change without notice.


All sales subject to standard terms and conditions.
2015 Ashcroft Inc.06/15

1.53

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA


Tel: 203-378-8281 Fax: 203-385-0408
email: info@ashcroft.com www.ashcroft.com

Type 1259 Process Pressure Gauge


PSIRANGES
Pressure psi
Range
0/15
0/30
0/60
0/100
0/160
0/200
0/300
0/400
0/600
0/800
0/1000
0/1500
0/2000
0/3000
0/4000
0/6000
0/10,000
0/20,000
Vacuum
30/0 in.Hg
34/0 ftH20
Compound
30Hg/15 psi
30Hg/30 psi
30Hg/60 psi
30Hg/100 psi
30Hg/150 psi
30Hg/300 psi

METRIC RANGES

Pressure kg/cm2 and bar


(Outer Scale)
Range
psi
0/1
0/14
0/1.6
0/22
0/2.5
0/35
0/4
0/55
0/6
0/85
0/10
0/140
0/16
0/220
0/25
0/350
0/40
0/550
0/60
0/850
0/100
1400
0/160
2200
0/250
3500
0/400
5500
0/600
8500
0/1000
14,000
0/1600
22,000
Vacuum Outer Scale
1/0
30Hg
Compound
1/0/1.5 30Hg/20
1/0/3
30Hg/40
1/0/5
30Hg/70
1/0/9
30Hg/125
1/0/15
30Hg/215
1/0/24
30Hg/340

METRIC RANGES

Pressure kPa
(Outer Scale)
Range
psi
0/100
0/14
0/160
0/22
0/250
0/35
0/400
0/55
0/600
0/85
0/1000
0/140
0/1600
0/220
0/2500
0/350
0/4000
0/550
0/6000
0/850
0/10,000
1400
0/16,000
2200
0/25,000
3500
0/40,000
5500
0/60,000
8500
0/100,000 14,000
0/160,00
22,000
Vacuum Outer Scale
100/0
30Hg
Compound
100/0/150 30Hg/20
100/0/300 30Hg/40
100/0/500 30Hg/70
100/0/900 30Hg/125
100/0/1500 30Hg/215
100/0/2400 30Hg/340

Pressure mPa
(Outer Scale)
Range
psi
0/0.1
0/14
0/0.16
0/22
0/0.25
0/35
0/0.4
0/55
0/0.6
0/85
0/1
0/140
0/1.6
0/220
0/2.5
0/350
0/4
0/550
0/6
0/850
Vacuum Outer Scale
0.1/0
30Hg
Compound
0.1/0/0.15 30Hg/20
0.1/0/0.3 30Hg/40
0.1/0/0.5 30Hg/70
0.1/0/0.9 30Hg/125
0.1/0/1.5 30Hg/215
0.1/0/2.4 30Hg/340

Order Coding Example


45

1259

04

OPTIONAL X VARIATIONS

100

SIZE

TYPE

SYSTEM
(TUBE & SOCKET)

CASE DESIGN
SOLID FRONT

PROCESS
CONNECTION SIZE

CONNECTION
LOCATION

OPTIONS
(X VARIATIONS)(1)

RANGE

ENGINEERING
UNITS

(45)
4

1259

(LJ) Hermetically Sealed, IP65

See above

(S) 316L(2)

(D) Dry (IP54)

(02) 1/4 NPT male

(P) K-Monel 500 tube,


Monel 400 socket(2)

(L) Liquid filled


(glycerin standard)
(IP65)

(04) 1/2 NPT male

(2)

(L) Lower

Max pressure 30,000psi

(BR)) Bar

(PD) Acrylic window

(KG) Kilograms/CM2

(SG) Safety glass

(KP) Kilopascal

(56) Flush mounting ring

(IMV) Inches of Mercury


Vacuum

(1)

BULLETIN PR-1259

All specifications are subject to change without notice.


All sales subject to standard terms and conditions.
2015 Ashcroft Inc.06/15

(#) PSI

(NH) St. St. Wired Tag

Others on request

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA


Tel: 203-378-8281 Fax: 203-385-0408
email: info@ashcroft.com www.ashcroft.com

PLUS! Performance
FlutterGuard
Nickel plated socket
WaII mounting bracket
Back flange
Front flange
U-clamp
Dry liquid-fillable gauge
Overload stop
Underload stop
Throttle screw
Throttle plug
Throttle plug
Throttle plug
Throttle plug
Throttle plug
Slotted link movement (decrease)
Slotted link (increase)
Adjustable pointer
Micrometer pointer
Red set hand stationary
Red set hand adjustable
Maximum pointer
Minimum pointer
Plastic window
Safety glass
Dial marking
Paper tag
Stainless steel tag
Absolute pressure
1
2% optional accuracy
1% optional accuracy
Retard scale
Black dial
Oxygen-cleaned gauges (gaseous)
Tip bleed
High and low electric contacts
Double high-electric contacts
Double low-electric contacts
Electric contacts off at low or
high and in-between
Silicone-filled gauge
Halocarbon-filled gauge
Carrying handle
Calibration Chart

TEST GAUGES

STD
STD

STD

STD

STD

STD
STD

STD

STD

PROCESS GAUGES

1009 (212, 312)

1009 (412, 6)

STD

STD

1008S
(1)

STD

STD(1)
STD(1)

STD

STD

STD

STD

STD

STD

STD

STD

STD

STD

COMMERCIAL GAUGES

STD

1001T

NOTES: The options listed above are only a partial listing. For other options on these or other pressure instruments please call the factory for availability.
Not all variations available for each size, connection, range in a specific gauge, model/type. Minimums may also apply.
(1) Available on 40mm and 50mm.

XGV
XGX
XCH
XC4

XLL
XSF
XNP
XBF
XFW
XFF
XUC
XLJ
XOS
XVS
XTS
XTU
XT4
XT5
XT7
XT9
XS4
XRJ
XAP
XMP
XSH
XEO
XEP
XEQ
XPD
XSG
XDA
XNN
XNH
XAB
XAJ
XAN
XRA
XBD
X6B
XTB
XED
XEE
XEF
XEG

GENERAL SERVICE

PRESSURE GAUGE TYPE


STAINLESS STEEL CASE
INDUSTRIAL GAUGES
SPECIAL SERVICE

TEST & PROCESS GAUGES


1490/1495 SERIES

DESCRIPTION

1005/1000 SERIES

CODE

1007P

Pressure Gauge Options

1008A

BULLETIN G7

3% 0.25%
3-22-1 0.5% %
-2% 1.0

All specifications are subject to change without notice.


All sales subject to standard terms and conditions.
Ashcroft Inc. 2015 04/15

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA


Tel: 203-378-8281 Fax: 203-385-0408
email: info@ashcroft.com www.ashcroft.com

ASME B40.100 recommends that normal operating pressure be confined to 25%-75% of the
scale. If pulsation is present in the process, maximum operating gauge pressure should not exceed
50% of the full-scale range.
CONCLUSION
To properly select a pressure gauge, consider the gauge process, range, environment, accuracy, dial
size, connection and mounting requirements.

7. PRESSURE RANGES

Consider the following mounting options when selecting a pressure gauge:


Stem mount lower connect
Wall/surface mount lower connect
Panel mount back connect
U-clamp flush mount back connect, for panel mounting
Front flange flush mount back connect, for panel mounting

6. CONNECTION LOCATION

Gauges are available with a variety of connections including NPT, DIN, JIS, BSP & SAE. Process
pressure gauges with 412 dial sizes or larger are most often supplied with a 12 NPT connection to
best support the gauge. Factors to consider when selecting a pressure gauge connection include
process pressures, gauge size and weight, space limitations, leak integrity, and past experience.

5. CONNECTION SIZE

The wetted parts of the pressure gauge, the Bourdon tube and socket must be compatible with the
process media. If not compatible with the wetted parts of the gauge, corrosion will occur. Corrosion
of gauge wetted parts will eventually cause gauge failure and possibly safety issues. When the gauge
wetted parts are not compatible with the process media, a diaphragm should be considered.

4. MEDIA / WETTED PARTS

Environmental considerations include ambient temperature, air-borne particulate, condensation,


humidity, water and chemicals, all of which can affect gauge performance.
Ambient temperature may affect the accuracy and integrity of the gauge. Gauges are available either
temperature compensated or non-temperature compensated. Ambient conditions may require that
the gauge be isolated from temperature extremes. When required, the gauge should be isolated from
temperature extremes with a flexible line assembly.
When ambient conditions are corrosive, contain a large number of particulate or if the gauge will be
exposed to a wet or humid environment like humidity, wash-downs or rain, specify a gauge that is
weatherproof/hermetically sealed or liquid filled.

3. CASE STYLE / MATERIAL

Pressure gauge dial sizes range from less than 1 to 16 diameters. Generally, readability requirements, space limitations and required gauge accuracy determine dial size. Accuracies of 0.25% or
0.5% generally have dial sizes of 412 or larger since more dial graduations are required.

2. DIAL SIZE

For a mechanical pressure gauge, accuracy is defined as a percentage of the full-scale range.
While requirements differ from one industry to another, the following are general guidelines:
Test Gauges and Standards: 0.25% through 0.10% full scale accuracies.
Critical Processes: 0.5% full scale accuracy.
General Industrial Processes: 1.0% accuracy. Less Critical Commercial Uses: 2.0% accuracy.
Refer to ASME B40.100 for more information on accuracy.

1. ACCURACY

Seven Steps to Select a Pressure Gauge

Pressure Gauge Accessories


CHEMIQUIP PRESSURE LIMITING VALVE (4)
Type Number

Conn.

Material

25-5460

4 NPTF

50-5500

4 NPTF

09-6430(1)

4 AMINCO

Available Ranges(3)
100-800 psi
303 SS
800-2500 psi
303 SS 2500-10,000 psi(1)
303 SS 10,000-18,000 psi(2)

Style
L
M
N
O

(1) Not available attached to instrument at factory.


(2) Available with model 09-6430 only.
(3) Use code XFS for factory setting.
Type of Service

Protects pressure instruments


against surges and pulsations.
Provides automatic positive
protection and accurate,
repeatable performance.
Automatic pressure shut-off.
Built-in snubber enhances
instrument, protecting
performance.

Porosity Designations

High viscous fluids (over 500 S.S.U.)


Oil (225-500 S.S.U.)
Water and light oils (30-225 S.S.U.)

C
D
E

Air or other gases


Extreme gas pulsations

G
HX

SIPHONS

In order to prevent live steam


from entering a pressure gauge

condensing hot vapors (not just


steam) are present.

water should be installed between


the gauge and the process line. If
freezing of the condensate in the
loop of a siphon is a possibility, a
diaphragm seal should be used to
isolate the gauge from the process
steam. Also use siphons whenever

Pig Tail SiphonNumber 1100


Series, 14 sizes: to 500 psi and
400F.

Type
Number

NPT
Conn.

Coil Pipe SiphonNumber 1098


Series, 14, 12 sizes: to 9550 psi
and 400F.

Material

Capacity

25-1098 I

Iron

500 psi @ 400F

25-1098 B

Brass

250 psi @ 400F

25-1098 S

ASTM A-106 seamless steel,


Grade A

338 psi @ 1000 to 3360 psi


from 20 to 400F

50-1098 S

ASTM A-106 seamless steel,


Grade A

333 psi @ 1000F to 3000 psi


from 20 to 400F

50-1098 SD

ASTM A-106 seamless steel,


Grade A

420 psi @ 1000F to 3740 psi


from 20 to 400F

50-1098 CD

ASTM A-213 seamless steel,


Grade T 22

1048 psi @ 1200F to 9550 psi


from 20 to 400F

50-1098 NS

Seamless stainless
steel, Type 316

294 psi @ 1500F to


3981 psi from 20 to 100F

50-1098 ND

Seamless stainless
steel, Type 316

336 psi @ 1500F


5840 psi from 20 to 100F

25-1100 A

Stainless steel

25-1100 I

Iron 638 Long

25-1100 IL

Iron 8 Long

25-1100 IN

Iron Angle

25-1100 B

Brass 538 Long

25-1100 BL

Brass 8 Long

BULLETIN ACC-1

500 psi @ 400F

Type 1100

Type 1098

250 psi @ 400F

All specifications are subject to change without notice.


All sales subject to standard terms and conditions.
Ashcroft Inc. 2007

Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA


Tel: 203-378-8281 Fax: 203-385-0408
email: info@ashcroft.com www.ashcroft.com