Tree falls
Rock masses/ rock avalanches
Snow slides
Local/ small scale earth slides
Provides barriers against shallow landslides
Protects against underwater instabilities
Stabilizes river banks
Can with stand maximum energies upto 8000 kJ, multiple impacts
Tests conducted
Advantages over wire rope nets, hexagonal meshes and heavy square mesh nets
Quicker to install
Easier to adapt
Stronger
Load bearing performance can be controlled
Easier to tension
Greater flexibility and dimensional stability
Minimal deflection
Free choice of anchor points
Fast mounting of the spiral rope net rolls over large areas
Suitable for reinforcing existing protection measures
Installation
T3 clips are used to connect the mesh panels reliably and without overlap
By means of spike plates the spiral net can be stretched over edges and rock spurs with
rock nails or rock anchors.
Geobrugg ring net stopped a 20 MT concrete cube with an impact velocity of 103 km/h
Geobrugg retain upto 1000 m3
Slope protection works
High tensile wire mesh
Can be optimized depending on subsoil with several mesh types
Small CO2 foot print and option to cover with natural vegetation
Advantages
If an economical spacing of nails are aimed simple wire meshes are unable to absorb the
occurring forces and to transmit them on to the nails
Type of products for slope stability
TECCO G65/2
S.No
1
2
3
4
5
6
7
8
9
10
Property
Mesh type
Mesh width
Wire diameter
Tensile resistance of wire, Zw
Tensile strength of mesh, Zm
Elongation longitudinal with tensile load Zm = 65 kN/m
Bearing resistance against puncturing, DR
Bearing resistance against shearing off, PR
Bearing resistance against slope- parallel tensile stress, ZR
Corrosion protection
Value
rhomboid
65 mm
2 mm
5.5 kN
65 kN/m
6.5 %
80 kN
40 kN
10 kN
94.5% Zn/5% Al + 0.5% add
on
TECCO G65/3
S.No
1
2
3
4
5
6
7
8
Property
Mesh type
Mesh width
Wire diameter
Tensile resistance of wire, Zw
Tensile strength of mesh, Zm
Elongation longitudinal with tensile load Zm = 150 kN/m
Bearing resistance against puncturing, DR
Bearing resistance against shearing off, PR
Value
rhomboid
65 mm
3 mm
12.5 kN
150 kN/m
6.5 %
180 kN/ 240 kN
90 kN/ 120 kN
9
10
30 kN/ 45 kN
95% Zn / 5% Al
TECCO G65/4
S.No
1
2
3
4
5
6
7
8
9
10
Property
Mesh type
Mesh width
Wire diameter
Tensile resistance of wire, Zw
Tensile strength of mesh, Zm
Elongation longitudinal with tensile load Zm = 250 kN/m
Bearing resistance against puncturing, DR
Bearing resistance against shearing off, PR
Bearing resistance against slope- parallel tensile stress, ZR
Corrosion protection
Value
rhomboid
63 mm
4 mm
22 kN
250 kN/m
7%
280 kN/ 370 kN
140 kN/ 185 kN
50 kN/ 75 kN
95% Zn / 5% Al
SPIDER S3-130
S.No
1
2
3
4
5
6
7
8
9
10
Property
Mesh type
Mesh width
Wire diameter
Tensile resistance of wire, Zw
Tensile strength of net, Zm
Elongation longitudinal with tensile load Zm = 220 kN/m
Bearing resistance against puncturing, DR
Bearing resistance against shearing off, PR
Bearing resistance against slope- parallel tensile stress, ZR
Corrosion protection
Value
rhomboid
143 mm
3 mm
12.5 kN
220 kN/m
8%
230 kN/ 300 kN
115 kN/ 150 kN
45 kN/ 70 kN
95% Zn / 5% Al
By tightly pressing the spike plate in the ground to be stabilized the mesh is tensioned
Design considerations
Local stability
o Instabilities near the surface and parallel to the slope
o Local instabilities between the nails
Global stability
Instabilities parallel to slope
1. Proof against a superficial layer sliding off
It is assumed that no excess hydrostatic pressure and no flow pressure is acting on the sliding
body
G = dead weight of cubic body
CxA = retaining influence of cohesion along sliding surface inclined by angle with
horizontal
V = force with stabilizing effect in the direction of nail
Which pretensions the mesh against slope surface
S = shear force which is to be absorbed by nail and transferred
into stable subsoil
C.
[ G*cos + V*sin(+)]*tan}