Positive Displacement Pumps - Controlled Volume
12 November 2013
General.......................................................... 2
Basic Design.................................................. 4
Accessories.................................................... 6
Vendor's Data................................................ 8
The following paragraph numbers refer to API STD 675, Second Edition, October 1994,
which is part of this Specification. The text in each paragraph below is an addition to this
Standard unless it is noted as an exception. Paragraph numbers which do not appear in
API STD 675 are new paragraph numbers to be inserted in numerical order.
1
General
1.1
Scope
1.1.1
This Specification, together with the Pump Data Sheet and Purchase Order,
defines the minimum mandatory requirements for positive displacement,
controlled volume pumps of the diaphragm and packed plunger types.
Diaphragm pumps using direct mechanical actuation are excluded from this
Specification.
1.1.2
1.1.3
1.1.4
1.2
Alternative Designs
1.2.1
1.3
Conflicting Requirements
1.3.1
Any conflicts between this Specification and other applicable Saudi Aramco
Materials System Specifications (SAMSSs), Engineering Standards (SAESs),
Standard Drawings (SASDs) or industry standards, codes and forms shall be
resolved in writing by the Company or Buyer Representative through the
Manager, Consulting Services Department, Saudi Aramco, Dhahran.
1.3.2
1.5
Referenced Publications
Material or equipment supplied to this Specification shall also comply with
the latest edition of the references listed below, unless otherwise noted.
Saudi Aramco References
Saudi Aramco Engineering Procedure
SAEP-302
17-SAMSS-503
17-SAMSS-515
34-SAMSS-621
34-SAMSS-622
34-SAMSS-623
34-SAMSS-820
34-SAMSS-821
34-SAMSS-831
Page 3 of 8
Screw Threads
ASME B1.13M
Basic Design
2.1
General
2.1.4
2.1.12
2.1.21
2.2
2.2.2
The Vendor's operating and instruction manual shall indicate torque values
to be used for the bolting of the cylinder head(s).
Page 4 of 8
2.2.5.1
2.3
2.3.1
2.3.6.2
Flat-faced flanges are not acceptable for materials other than cast iron or
Ni-resist alloys.
2.5
Diaphragms
2.5.2
2.5.5
2.7
2.7.1
(Exception to second sentence) The actual pump internal relief valve setting
shall be between 110% and 120% of the rated discharge pressure.
2.11
Lubrication
2.11.1
2.12
Capacity Adjustment
2.12.1
2.13
Materials
2.13.1
General
2.13.1.9
2.14
2.14.3
Pump nameplates shall also include Purchase Order number, service, pump
mark number, liquid pumped, pulsation damper charging pressure, lubricant,
Page 5 of 8
Accessories
3.1
Drivers
3.1.1
3.2
3.2.2
3.4
3.4.1
General
3.4.1.1
3.4.2
Control Systems
3.4.2.3
3.4.3
3.4.3.1
2)
3)
3.4.4
Instrumentation
3.4.4.2
Thermowells
Thermowells shall be in accordance with Form 8020-418-ENG or
Form 8020-418-M-ENG. Wake and natural frequency calculations shall be
performed in accordance with ASME PTC 19.3 Part 3. The insertion length
shall satisfy a wake to natural frequency ratio of 0.8.
Page 6 of 8
3.5
Piping
3.5.1
General
3.5.1.1
3.6
3.6.1
rated suction pressure or 100 kPa gauge (15 psig) whichever is less;
b)
rated discharge pressure or 100 kPa gauge (15 psig) whichever is less.
The Vendor shall be responsible for ensuring that the following
situations are avoided:
- cavitation in the suction or discharge of the pump;
- over delivery due to suction losses or uncontrolled delivery;
- exceeding maximum allowable working pressure of pressure
containing parts (including auxiliaries).
The Vendor shall provide any fittings required for charging the pulsation
dampers. These shall be securely fastened to the pump.
3.6.2
General
4.1.1
4.4
4.4.3.4
All alloy casings shall be provided with plugs of the same material as the
casing.
4.4.3.8
4.4.3.9
A complete set of spare gaskets and O-rings shall be included with the
equipment when shipped.
Page 7 of 8
Vendor's Data
5.3
Contract Data
5.3.7
12 November 2013
Revision Summary
Revised the Next Planned Update, reaffirmed the content of the document, and reissued
as major revision.
Page 8 of 8