Sie sind auf Seite 1von 104

Background

This database contains a list of FOG related devices/products/systems along with contact details for the Manufacturers and Suppliers. Information
from the Manufacturer/Supplier websites has been included to supply further data relating to the systems/devices/products.
Information relating to trials of devices/products/systems has been included and is accessed by clicking on the 'GO' hyperlink associated with a
system/device/product. This information has been obtained from either:
Trials carried out during the WRc FOG Project, OR
Trials conducted by the WRc FOG Project contributors outside of the WRc FOG Project.
Where this information is included it reports on the trial that took place. This information should not be used as a WRc recommendation for a
system/device/product. This is because the success or not of a particular product will depend upon its application. Due regard should therefore be
taken of the environment in which it will be used and its method of application. For example with microbiological products consideration should be
given to effluent flow rates, effluent concentrations, contact times etc.
It should be noted that this is not an exhaustive list of FOG related devices/products/systems or Manufacturers and Suppliers.
The information in this database has been obtained and updated during the lifetime of the WRc FOG Project.
The information in this database is correct at the time of issue September 2008.

Instructions for use:


1
2
3
4
5
6

Go to 'Products Database' tab.


Go to 'Location product is installed / applied' and click
Select from the drop down list the location where the system/device/product is required.
Go to 'Product Category' and click
Select from the list the type of system/device/product required.
If 'Physical Separator' is selected from 'Product Category' - Go to 'Product Sub-Category' and select either 'External' or 'Internal'

Note: This process selects a range of devices/products/systems that are suitable for intstallation / application for the location selected.

Note: This process selects a range of devices/products/systems that are suitable for intstallation / application for the location selected.

Location product is
installed / applied

Product Category

Septic Tanks

Microbiological

Septic Tanks

Microbiological

Commercial Kitchens

Physical Separator

Product Sub-category Product Name

Company Name

Contact Name

An innovative bio product developed for the bio-augmentation of dissolved air flotation (DAF) units
and industrial grease traps. It comprises a highly concentrated powdered formulation, containing a
Dissolved oxygen (Aerobics)
synergistic blend of selectively adapted bacteria, surfactants, and enzymes specifically formulated for
the bio-degradation of oil and grease in sewer lines and municipal sewage treatment plants.

Accepta

Accepta 7111

Accepta 7111 is an innovative, eco-friendly product developed specifically for the bio-augmentation of
industrial grease traps and dissolved air flotation (DAF) units. Accepta 7111 comprises a green liquid
Dissolved oxygen (Aerobics)
formulation based on emulsifiers, enzymes and selectively adapted micro-organisms specially
formulated for the effective bio-degradation of oil and grease.

Grease Trap

Grease traps have been developed to minimising the problems caused by the unwanted
accumulation of waste solids, grease and fats. Grease traps incorporate an innovative high
performance mesh system that acts to effectively filter out solid organic waste before it enters the
drainage system, minimising its impact on drains, pipes, interceptors and wastewater discharge
quality.

Accepta 7112

Internal / External

Website Basic Product related info

Product requirements

Use every day

Contact Address

Contact Phone No

Country

Quay West,
Naitle Richardson Trafford Wharf Road,
Manchester, M17 1HH. UK

+44 (0) 161 240 2100

UK

Accepta

Quay West,
Naitle Richardson Trafford Wharf Road,
Manchester, M17 1HH. UK

+44 (0) 161 240 2101

UK

Accepta

Quay West,
Naitle Richardson Trafford Wharf Road,
Manchester, M17 1HH. UK

+44 (0) 161 240 2100

UK

Accepta

Quay West,
Naitle Richardson Trafford Wharf Road,
Manchester, M17 1HH. UK

+44 (0) 161 240 2100

UK

Acqua International
Group

David Carnell

Tel: (0061) 392962115

Accepta 7141, an innovative, eco-friendly biological (bacteria/ enzymes/ surfactants) grease trap and
drainage cleaner. It is the perfect solution to those drainage problems caused by the build-up of
grease, oil and fat . It is an innovative high performance liquid formulation based on four selected
biological strains developed to digest grease, proteins, starch and cellulose. Its advantages include:

Commercial Kitchens

Physical Separator &


Microbiological

Accepta 7141

- Allows the rapid 'start-up' of grease traps.


- Reduced maintenance
- Allows grease traps to work
better and longer with reduced servicing.
- Keeps drain lines clean and free flowing.
- Controls odours effectively.
- Long shelf life.
- Minimise Health & Safety risks.
- Can be handled without danger to staff.

Commercial Kitchens

WwTW

Grease Separators

Commercial Kitchens

Industrial Use

Commercial Kitchens

Drains / Sewers

Physical Separator

Microbiological

Microbiological

Microbiological

Microbiological

Microbiological

Microbiological

External

Vertical Gravity
Separator

Advetec 100

The Vertical Gravity Separator is a cylindrical multi-plate oil water separator, that uses gravity as its'
separating mechanism.

Advetec 100 is an intra-cellular micro- nutrient additive for application within a WwTW. The product is
used to combat fats, oils and greases atr the bar screens and throughout the WwTW.

Advetec 400

Advetec 400 significantly reduces fats, oils and greases in grease traps along with a specially
designed dispenser, is utilised remotely by being suspended below manhole cover.

Advetec 440

Advetec 440 is an intra-cellular micro-nutrient additive for application within fast food outlets and
restaurants. The product is used to combat the build-up of fats, oils and greases throughout drainage
systems and within fat traps.

Advetec Ltd.

Advetec Ltd.

Advetec Ltd.

Mick Lohan
Craig Shaw

Advetec Manufacturing Limited


Unit A
Tel: 0 1761 433434
Upper Lentney Farm Building
Radstock
Fax: 0 1761 433365
Somerset
BA3 5SL

UK

Mick Lohan
Craig Shaw

Advetec Manufacturing Limited


Unit A
Tel: 0 1761 433434
Upper Lentney Farm Building
Radstock
Fax: 0 1761 433365
Somerset
BA3 5SL

UK

Mick Lohan
Craig Shaw

Advetec Manufacturing Limited


Unit A
Tel: 0 1761 433434
Upper Lentney Farm Building
Radstock
Fax: 0 1761 433365
Somerset
BA3 5SL

UK

Mick Lohan
Craig Shaw

Advetec Manufacturing Limited


Unit A
Tel: 0 1761 433434
Upper Lentney Farm Building
Radstock
Fax: 0 1761 433365
Somerset
BA3 5SL

UK

Advetec 460

Advetec 460 is an intra-cellular micro-nutrient additive for delivery within food processing plant. The
product is used to combat fats, oils and greases throughout the plant drainage systems.

Advetec Ltd.

AM-301

24 species of bacteria for the degradation of fats, oils, protein, starch, sugars and other compounds
associated with food production, processing, preparation, or service. Higher efficiences of organic
removal result in lower volatile solids and lower cake volumes. By increasing the biological efficiency
of the WwTW, the plant is able to handle greater volumes of through - put with lower operational
costs.

Advanced Microbial

5738 S. 116th West Ave. Sand


1-800-984-9961
Springs, OK 74063

USA

Aluline Commercial
Drainage Specialists

Aluline Ltd,
1 Aldborough Street,
Blyth,
Northumberland,
NE24 2EU
England

UK

Alubio "L" Block

Dissolve block attacks fats, oil and grease.

+44 (0) 1670 544322

Location product is
installed / applied

Universal

Product Category

Product Sub-category Product Name

Microbiological

Alubio- Block / GT

WwTW / Pumping Stations Microbiological

AluBio - Block TP/LS

WwTW / Pumping Stations Microbiological

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Universal

Universal

Commercial Kitchens

Universal

Pumping Stations

Physical Separator

Physical Separator

External

Internal

Microbiological

Microbiological

Microbiological

Physical Separator

Microbiological

Microbiological

Internal

Website Basic Product related info

Product requirements

Block GT: designed to liquefy and consume organic wastes that are commonly found in grease traps,
sewerage, drainage and septic systems.

AluBio - Block TP/LS: designed for industrial treatment plants and lift stations to digest organic
wastes, grease, fats and oils that accumulate and keep them free flowing.

QuickBlock

QuickBlock: a special fast dissolving block designed to provide an appropriate amount of shock
dosage into the system before the maintenance slow dissolve block takes effect.

Oil Separator

Aluline Oil separator systems are designed to efficiently separate free oil substances from polluted
rain water and waste water. Essential for the treatment of waste water/polluted rainwater from such
installations as: industrial plants, etc

Company Name

Contact Address

Contact Phone No

Country

Aluline Commercial
Drainage Specialists

Aluline Ltd,
1 Aldborough Street,
Blyth,
Northumberland,
NE24 2EU
England

+44 (0) 1670 544323

UK

Aluline Commercial
Drainage Specialists

Aluline Ltd,
1 Aldborough Street,
Blyth,
Northumberland,
NE24 2EU
England

+44 (0) 1670 544324

UK

Aluline Commercial
Drainage Specialists

Aluline Ltd,
1 Aldborough Street,
Blyth,
Northumberland,
NE24 2EU
England

+44 (0) 1670 544325

UK

Aluline Commercial
Drainage Specialists

Aluline Ltd,
1 Aldborough Street,
Blyth,
Northumberland,
NE24 2EU
England

+44 (0) 1670 544322

UK

Aluline Ltd,
1 Aldborough Street,
Blyth,
Northumberland,
NE24 2EU
England

+44 (0) 1670 544322

UK

AG Grease Trap

Experience of surveying, specifying, supplying, installing and maintaining Grease Traps in


commercial kitchens, such as hotels is unrivalled

Aluline Commercial
Drainage Specialists

Drain Gel

DrainGel is a highly-concentrated gel which clings to the sides of drains and pipes. DrainGel can also
be easily sprayed into cracks and crevices and onto hard-to-access non-drain sites. DrainGel's
formulation incorporates specialized microorganisms (bacteria) in combination with biological support
ingredients and essential growth factors. This unique formulation promotes improved performance in
degradation of organic materials in both aerobic and anaerobic environments. Also it's specifically
designed to block the production of odours frequently occurring in drain lines, sewer lines and grease
traps.

American Bio-Systems

LLMO G-1

In the Liquid Live Micro Organism (LLMO) technology the bacteria are alive in a dormant state and
suspended in a liquid solution. Bacterial growth resumes at virtually 100% recovery rate when
introduced to appropriate nutrients in a biological waste treatment system. LLMO is a blend of several
selected strains of saprophytic bacteria that accelerates the digestion of organic wastes in the
sewage treatment system through the process of natural bacterial action on the wastes. LLMO
contains both aerobic and anaerobic bacteria to ensure maximum effectiveness under varying plant
conditions.

Can be used by pouring the product


directly into the waste to be treated.
However, for best results, should be
used with an Automatic Bacterial
Injection (ABI) Delivery System.

GelPac G

For treatment anywhere grease/fat is a problem. Continuous addition optimises results. GelPac
technology involves immobilising bacteria in a slow-release gel. When a GelPac is added to water,
the gel slowly dissolves, which releases GelPac bacteria to the waste stream. Whereas liquid LLMO
is often added daily, GelPacs are generally replaced once per month or per week..

Automatic Bacterial Injection (ABI)


Delivery System .
Enclosed area
Electricity
Water

Contact Name

USA

Amitek

AMITEK SOLUTIONS (PTY)


Spike Becker
LTD
[spike@amitek.co. Head Office
+27 11 782 4608
za]
PO Box 2405 Pinegowrie 2123
South Africa

South
Africa

Amitek

AMITEK SOLUTIONS (PTY)


Spike Becker
LTD
[spike@amitek.co. Head Office
+27 11 782 4608
za]
PO Box 2405 Pinegowrie 2123
South Africa

South
Africa

South
Africa

South
Africa

FatFoe

Grease trap to solve problems like: Blocked drain pipes, Blocked sinks, Fat traps always full, Space
constraints, Building control regulations, Sewer plant blockages, Kitchen odours

Amitek

AMITEK SOLUTIONS (PTY)


Spike Becker
LTD
[spike@amitek.co. Head Office
+27 11 782 4608
za]
PO Box 2405 Pinegowrie 2123
South Africa

Drain Free

Do not use the product in


combination with chemical drain
It's an ultra-concentrated suspension of live bacteria and enzymes that digest grease, scum and
treatments or disinfectants. It will not
septic sludge. These organisms are a selection of naturally occurring bacteria that are nondissolve tree roots. It will not
pathogenic (disease-causing), non-toxic, non-caustic and totally safe for humans, animals and the
degenerate inorganic compounds
Amitek
environment. The selected bacteria in it perform the natural function of degrading organic waste such such as metals, plastic, sand and
as cellulose, plant and animal fibre, fat, oil and grease (FOG).
silt. Storage +/1 18 C. Automatic
Drain Free dosing unit will be
required

AMITEK SOLUTIONS (PTY)


Spike Becker
LTD
[spike@amitek.co. Head Office
+27 11 782 4608
za]
PO Box 2405 Pinegowrie 2123
South Africa

Bacta-Pur Bactivator

The Bacta-Pur Bactivator assures the continual presence of an optimal community by seeding
specific organisms to accomplish a particular task, for example the biological removal of grease, or
cleaning sewers.

Ameco

Ameco Ltd
245 Pineridge
The Park
Findhorn
Forres
Moray
IV36 3TB
Scotland

Tel: 0 1309 691846


Mob: 0 7905 007883

UK

Location product is
installed / applied

Product Category

Commercial Kitchens

Microbiological

Commercial Kitchens

Physical Separator

Product Sub-category Product Name

Website Basic Product related info

Product requirements

Company Name

Contact Name

Contact Address

Contact Phone No

Country

The gobbler contains an amazing 8 million micro - organisms (enzymes) to every 1 ml of product, that
quickly digests grease and odour causing bacteria. We have incorporated the latest four strains of
intelligent enzymes, which have the ability to hibernate if the presence of caustics and bleach are
detected and will resume digestion when the hazard has passed

Anglo - Net2

Lemon Works, Russel Gardens,


Wickford, Essex, SS11 8BH

UK

ECH2OTM

Oil and grease and laden wastewater is gravity fed through a two stage solid filter. This solid filter
removes both settle able and suspended food particles down to 40 microns.

API Industries Inc.

API Industries Inc. 6590 E.


40th St.
918 664-4010
Tulsa, Oklahoma U.S.A. 74145

USA

Microbiological

Bio Treat 2000

Blend of surfactant, enzymes, non-harmful bacteria and nutrient salts. A dry powder (more stable
with longer shelf life) or a liquid (easier to dispense automatically). Breaks down organic solids,
reducing odour and corrosion. The primary enzymes include amylase, glucanase and proteinase
while the microbial content is composed of 8 strains of bacteria belonging to the Bacillus
Pseudomonas and Chaetomium Genera.
http://www.enterpriselink.co.uk/ecluster/DisplayArticle.asp?ID=2494

Valley Works
Thurning Rd.
Luddington
Peterborough
PE8 5QX

01832 293600

UK

Commercial Kitchens

Microbiological

Aquazar
Envirofloc GD

A blend of natural microbes which digest FOG.

Aquazur UK Ltd
(PermaCare
International)

Chapel House
Alma Road
Windsor
Berkshire
SL4 3HD

01753 712000

UK

Commercial Kitchens

Consultant

Service

Environmental consultancy.

AWN Consulting

Fergal Coallaghan

The Tecpro Building


Clonshaugh Industrial Estate
Dublin 17

Tel: 0035318474220
Fax:
035318474257

Ireland

Commercial Kitchens

Microbiological

Gemi

A unique, patented bio- treatnment (bacteria) system to provide effective removal of wastewater fats,
grease and oils for commecial catering and food processing applications with minimal operationg
costs.

BioClear
Environmental
Services Ltd

Paul Prince

Unit 10, Carver Rd, Astonfields 01785 254553


Ind Est, Stafford ST16 3HR
07710 014964

UK

Bio- treat

Bio- treat is a range of bio-consumables formulated for use with bio-cultivation systems to improve
commercial and industrial wastewater treatment. The solutions contain naturally occurring
microorganisms (bacteria), selected for their ability to digest specific wastes, blended with additional
ingredients to assist the bio-cultivation process. A blend of micro- organisms, selected for their
superior ability to digest FOG. and other organic matter.

BioClear
Environmental
Services Ltd

Paul Prince

Unit 10, Carver Rd, Astonfields 1786 254553


Ind Est, Stafford ST16 3HR
07710 014964

UK

Biological solution developed for commercial applications to provide low cost maintenance of drains
and grease interceptors. The product is simple to apply either manually or with an automatic
dispenser. The blend of non toxic naturally occuring micro-organisms (bacteria) have been selected
for their superior ability to digest oils, fats, greases and other organic matter blocking drainage
systems. The solution also contains free enzymes and surfactants to aid the digesting process
immediately after dosing.

BioClear
Environmental
Services Ltd

Paul Prince

Unit 10, Carver Rd, Astonfields 1787 254553


Ind Est, Stafford ST16 3HR
07710 014964

UK

BioClear
Environmental
Services Ltd

Paul Prince

Unit 10, Carver Rd, Astonfields 01785 254553


Ind Est, Stafford ST16 3HR
07710 014964

UK

Universal

Commercial Kitchens

Microbiological

Grease Gobbler

Internal

Continuous dosage depending on


requirements. The product must be
diluted with final effluent, it is not
recommended to use potable water
because it contains chloride. Before
APPS Ltd.
application, leave it for 24 hours in
an open top container.
They need oxygen (aerobic) and are
more effective around 25C
temperature

Phillip Christmas
Carla Phillips

Commercial Kitchens

Microbiological

Bio Clear DG-X


BioDegreaser

Commercial Kitchens

Microbiological

S3000 Automatic Drain


Programmable automatic dispenser for time controlled dosing of BioClear GD-X Bio-Degreaser.
Dispenser

Commercial Kitchens

Microbiological

BFL Drain Clean +

BFL Drain Clean brings together the benefits of biodegradable surfactants and natural citrus extract
to penetrate and dissolve organic deposits in drains. These surfactants help to emulsify and mobilise
organic material so that drains can be restored to free flowing. BFL Drain Clean can be used to
remove fat/grease deposits in drains prior to starting a dosing programme using the microbial product

BioFuture Ltd

David Cordial

62c Heather Road


Sandyford Industrial Park
Dublin 18

t ; + 353 1 2149749
f : + 353 1 2149767

Ireland

Commercial Kitchens

Microbiological

BFL Grease Clean

BFL Grease Clean - biological digester. Once cleaned using BFL Drain Clean an ongoing
maintenance programme using BFL Grease Clean will keep the drains clean.

BioFuture Ltd

David Cordial

62c Heather Road


Sandyford Industrial Park
Dublin 19

t ; + 353 1 2149749
f : + 353 1 2149768

Ireland

BFL 5150PS

It contains a wide range of micro-organisms that have been specially selected for their ability to
efficiently degrade grease. They also are efficient in degrading other organic waste materials. These
bacteria produce a range of enzymes that degrade grease, starch, protein and cellulose. The key to
the degradation of grease and other compounds that are not water-soluble is the production of bio
surfactants. This helps to emulsify the grease so that it can be degraded more efficiently. The
bacteria in BFL 5150PS have been selected for their ability to produce bio surfactants. A small
quantity of biodegradable surfactant is included to start the process until the bacteria produce their
own bio surfactants to continue the degradation process.

Biofuture Ltd

62c Heather Road


Sandyford Industrial Park
Dublin 18

01-2149749

Ireland

BIO-TREAT GF

BIO-TREAT GF Accelerates the Breakdown of Grease and Fats


Improves Waste Water Treatment and Discharge Quality
A Natural Biological Process
Cost Effective
Safe and easy to apply
The build up of fats, oils and grease clogs up sewer lines, reduces pumping at
pumping stations and creates processing problems for plant operators in waste water
treatment facilities. Continuous use of BIO-TREAT GF on a preventative
maintenance basis will reduce grease accumulation.
The product comprises a blend of diverse micro-organisms, known for their
ability to break down oils, fats and grease. The addition of BIO-TREAT GF to
waste water maximises the effectiveness of organic decomposition by ensuring
that the micro-organisms responsible for digesting specific organic compounds
are present in high concentrations. This is safe, economic and a proven
method.

Bio-Industries Ltd,
Unit 66d Heather Road,
Sandyford Industrial Estate,
Dublin 18,
Ireland

Tel: +353(1)2941025
Fax: +353(1)2941027

Ireland

Pumping Stations

WwTW

Microbiological

Microbiological

Requires a cold water supply and


230v or 110v electric supply to
operate.

The application of any biological


product requires an understanding of
the specifics
of site conditions. The information
gained from each site is used to
determine
whether the BIO-TREAT GF is the
Bio-Industries Ltd
best product for treatment and
the specific dosage required. On
going analysis can be conducted
during
treatment in order to optimise the
treatment process.

Adrian Hughes

Location product is
installed / applied

Product Category

Product Sub-category Product Name

Website Basic Product related info

Product requirements

Company Name

Contact Name

Contact Address

Contact Phone No

Country

The application of any biological


product requires an understanding of
the specifics
of site conditions. The information
gained from each site is used to
determine
whether the BIO-TREAT GF is the
Bio-Industries Ltd
best product for treatment and
the specific dosage required. On
going analysis can be conducted
during
treatment in order to optimise the
treatment process.

Adrian Hughes

Bio-Industries Ltd,
Unit 66d Heather Road,
Sandyford Industrial Estate,
Dublin 18,
Ireland

Tel: +353(1)2941025
Fax: +353(1)2941027

Ireland

Daily use.

Bionetix UK

John Duffy

Bionetix UK, North Dean


Business Park, Stainland Road, 01422 363462
Greetland, Halifax, HX4 8LR

UK

Commercial Kitchens

Microbiological

Bio-degreaser

BIO-DEGREASER biologically digests grease and other organic


waste build up, turning it into carbon dioxide (CO2) and water (H2O).
The micro-organisms in BIO-DEGREASER go to work as soon as
they contact waste, anywhere in the plumbing system (grease traps,
joints and drain lines) breaking down and digesting grease
and solid waste wherever it accumulates. This action keeps
drain lines and grease traps functioning properly as long as
treatment is applied.

Domestic Kitchens

Microbiological

Drainflush

For clearing drains and grease-traps and preventing future blockages: drainflush breaks down fats,
greases and oils. It can be dosed directly into drains to clear and prevent blockages; breaks down
fats, greases and oils; reduces unpleasant odours

Bionetix UK

John Duffy

Bionetix UK, North Dean


Business Park, Stainland Road, 1423 363462
Greetland, Halifax, HX4 8LR

UK

Bio-sol

Graham Mellish

PO Box 18, Mirfield, West


Yorkshire, WF14 0XB

0800 389 6076

UK

None (Simply suspend the Bio-Cube


into the treatment area, hanging the
Bio-Cube the way into grease trap
or nearest point to inflow pipe. The
Bio-sol
Bio-Cube will dissolve slowly
providing optimal efficiency and
treatment)

Graham Mellish

PO Box 18, Mirfield, West


Yorkshire, WF14 0XB

0800 389 6076

UK

BioStim

Jerry Pressley

BioStim, LLC
8718 Botts Lane
San Antonio, Texas 78217

Tel: (210) 821-5977


Fax: (210) 822-7717
(800) 338-8812

USA

Commercial Kitchens

Microbiological

Eco Trap

ECO TRAP LIQUID was developed to break-down grease, fats, proteins, cellulose and starches
which are normally difficult to eliminate and clog waste disposal systems. The grease trap treatment
product works quickly and effectively with no harmful effects on plumbing and does not create odours
or noxious gases. These bacterial strains become activated when exposed to water and shortly begin
production of the enzymes required to biodegrade these insoluble substrates. The strains of bacteria
are ravenous feeders of organic waste. As this digestive process begins, the water slurry of waste is
dark and cloudy. As the organic matter is biodegraded by the bacteria, the slurry becomes light and
clear.

Universal

Microbiological

Eliminator

Highly Concentrated Solid with Microbes & Enzymes to remove oil and odour. Eliminator is an
industrial strength concentrate, formulated to remove all common soils, grease, oil, dirt, wax, gum,
dye, inks, carbon, smoke and exhaust stains.

Universal

Microbiological

PDM7 BIO CUBES

Highly Concentrated Solid with Microbes & Enzymes to remove oil and odour

BioPlug L

The BioPlug L is a timed-release, multi-strain, microbial formula specifically designed for efficient
digestion of fat, oil, and grease (FOG) and organic buildup in lift stations. The BioPlug L requires no
Bio Floter (flocculation device)
maintenance other than monthly plug replacements for optimum digestion.

Drains / Sewers / Pumping


Microbiological
Stations

BioPlug CS

The BioPlug CS has been specifically designed to provide timed-released, multi-strain, microbes for
optimum digestion of fat, oil, and grease (FOG) and organic buildup in sewer lines (accessible by
Bio Floter (flocculation device)
manhole covers) and commercial lift stations. The BioPlug CS requires no maintenance other than
monthly plug replacement(s).

BioStim

Jerry Pressley

BioStim, LLC
8718 Botts Lane
San Antonio, Texas 78218

Tel: (210) 821-5977


Fax: (210) 822-7717
(800) 338-8813

USA

Commercial Kitchens

Microbiological

Bio Pill

The BioPill is a 100 percent multi-strain, microbial formula designed to digest fat, oil, and grease
(FOG) and other organic matter that accumulates in indoor grease interceptors (traps) and drain lines

BioStim

Jerry Pressley

BioStim, LLC
8718 Botts Lane
San Antonio, Texas 78217

Tel: (210) 821-5977


Fax: (210) 822-7717
(800) 338-8812

USA

Grease Separators

Microbiological

Super Aug Pill

Super Aug Pill is a timed-released, multi-strain, highly-concentrated, microbial formulation designed


to "shock treat" the outdoor grease interceptor (trap).

BioStim

Jerry Pressley

BioStim, LLC
8718 Botts Lane
San Antonio, Texas 78218

Tel: (210) 821-5977


Fax: (210) 822-7717
(800) 338-8813

USA

Grease Separators

Microbiological

Super Aug Formula

Super Aug Formula is a multi-strain, highly-concentrated, microbial formulation designed to "shock


treat" the outdoor grease interceptor (trap).

BioStim

Jerry Pressley

BioStim, LLC
8718 Botts Lane
San Antonio, Texas 78219

Tel: (210) 821-5977


Fax: (210) 822-7717
(800) 338-8814

USA

B220

Degrades grease Deposits in Pipes and Sump boots & Tanks

Bio-Systems

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2972

South
Africa

B220 R

It has been formulated from a blend of natural micro-organisms that have been selected and taken
from their environment (sewage effluent) and adapted to the (often), harsh conditions found in
municipal pump stations and sewers, particularly those transporting effluent from industrial areas. It is
reinforced with selected free enzymes and micro-nutrients to ensure immediate activity when the air
dried powder is re-hydrated in liquid effluent No genetically modified cultures are used. Powder
soluble in water.

Bio-Systems

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2972

South
Africa

Bio-Systems

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2972

South
Africa

Drains / Sewers / Pumping


Microbiological
Stations

Drains / Sewers / Pumping


Microbiological
Stations

Drains / Sewers / Pumping


Microbiological
Stations

Fog Free

Biological Digester - Made up product. Degrades FOG in kitchen traps.

Commercial Kitchens

Microbiological

Commercial Kitchens

Microbiological

Drain Flow

Biological Digester - Made up product. Degrades FOG stop odour.

Bio-Systems

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2973

South
Africa

Commercial Kitchens

Microbiological

Dop-A-Day

Biological Digester - Made up product. Degrades FOG stop odour.

Bio-Systems

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2974

South
Africa

Drains / Sewers

Microbiological

L800 UK

Biological Digester - Liquid product. Degrades FOG under jetting pressure.

Bio-Systems

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2972

South
Africa

Location product is
installed / applied

Product Category

Product Sub-category Product Name

Drains / Sewers / Pumping


Microbiological
Stations

Drains / Sewers / Grease


Separators

Microbiological

Drains / Sewers / Grease


Separators

Microbiological

Commercial Kitchens

Grease Separators

Microbiological

Commercial Kitchens

Commercial Kitchens

Pumping Stations

Universal

Physical Separator

L1020

Biological Digester - Liquid product. Reduce grease in drains and sumps.

BIOBUGGreen

BIOBUGGreen is specially formulated and packaged for direct addition to drains and grease traps
in homes, restaurants and commercial buildings.It contains microorganisms that are capable of
degrading a wide range of oils and greases under aerobic, facultative, anaerobic conditions
combained with natural biological enhancers, micronutrients and macronutrients.

BIOBUGRed

BIOBUGRed is an improved biological product, specifically formulated and packaged for use in
pumping stations. It also contains specialty penetrants and surfacantts which loosen and liquefy
heavy grease deposits, thereby assisting in their biodegradation.

Microbiological

Biotal GD is a specially selected blend of non-toxic natural microbes (bacteria/ enzymes), which
digest oils, fats, greases and other organic matter blocking drainage systems. The primary
application of Biotal GD is in restaurants, hotels, and food preparation and processing
establishments, where regular quantities of solid food wastes find their way into the drainage system.

Organicas Grease
Trap Treatment
Product

Microbiological

External

Microbiological

Microbiological

Website Basic Product related info

A unique formulation containing natural non-pathogenic bacteria with enzymes, non-ionic surfactants
and oxygen containing compounds. This product was developed to break-down grease, fats,
proteins, cellulose and starches which are normally difficult to eliminate and clog waste disposal
systems. Grease Trap Treatment Product works quickly and effectively with no harmful effects on
plumbing and does not create odours or noxious gases. These bacterial strains are preserved using
preservatives and become activated when exposed to water and shortly begin production of the
enzymes required to biodegrade these insoluble substrates. The strains of bacteria are ravenous
feeders of organic waste. As this digestive process begins, the water slurry of waste is dark and
cloudy. As the organic matter is biodegraded by the bacteria, the slurry becomes light and clear.

Product requirements

Company Name

Bio-Systems

Country

Bio-Systems SA
PO Box 136
Simon's Town 7995
South Africa

+27 21 786 2973

South
Africa

Unit F1 Kings Drive Kingmoor


Park South, Carlisle, Cumbria,
CA6 4RD

Tel: 01228522255
Fax: 01228522288

UK

Bio-Systems
International

Rick Thomas

Unit F1 Kings Drive Kingmoor


Park South, Carlisle, Cumbria,
CA6 4RD

Tel: 01228522255
Fax: 01228522289

UK

Peter Graham

Biotal Limited
Collivaud House
Ocean Way
Cardiff
CF24 5PD
United Kingdom

Reception Tel: 029 2047


5550
Fax: 029 2047 5598
UK
Tel: 029 2047 5550 Mob:
07884 312386

Birch Farm
Southery Road
Feltwell
Norfolk. UK
IP26 4EN

Tel: 01277 889333

UK

Biotal

Biotank

Grease Guard

Grease Guard is a liquid grease fat treatment which distinguishes all greases and most processed
fats within the grease trap and drainage system. Used daily your grease trap and drainage system
will be free of the grease and fats which cause 99% of the problems caused in the drains outside
most busy kitchens. The product comes in 25 liters containers and can be dosed by automatic pump
or nmanually poured into the sink or grease trap.

Black Hat

Mark Conway

14/15 Harvey Close, Crowther


Industrial Estate, Washington
NE38 0AB

0191 415 9090

UK

Grease Traps

The grease trap works by slowing down the flow of warm or hot greasy water allowing it to cool. As
the water cools, the grease and oil seprate and float to the top of the grease trap. The cooler water
containing less grease continues to flow down the pipe to the sewer. The grease is trapped by baffles,
which cover the inlet and outlet of the tank, preventing grease from flowing out of the trap.

Black Hat

Mark Conway

14/15 Harvey Close, Crowther


Industrial Estate, Washington
NE38 0AB

192 415 9090

UK

The product is supplied in opaque


25-liter canisters. It can be manually
poured down the drain; or it can be
automatically dosed via an
BRE
electronically controlled positive
displacement pump that injects the
product directly into the drainage
line.

Karim Esmail

Garston, Watford, Herts, WD25


01923 664000
9XX

UK

Karim Esmail

Garston, Watford, Herts, WD25 01923 664630


9XX

UK

Eco-Bio 608

Eco-Bio product use a blend of natural plant extracts, micronutrients, vitamins and bio stimulants to
enhance and accelerate the action of indigenous micro organisms within the system. A range of
products are available, however, the Eco-Bio 608 fatbuster solution is the most applicable fot he
control of FOG.

Eco-Bio

The Eco-Bio Process is one of the most advanced, versatile and


economic methods for the treatment of waste water from a broad
range of sources. The process involves the addition of natural nutrients,
biocatalysts and active ingredient Dakarin, which accelerate the
indigenous microorganisms (bacteria) that are naturally present in the waste
water, to achieve complete odour elimination and decontamination of
the water to international discharge and recycle standards.

BRE

Burbank Grease
Services

606 Basset street, DeForest,


WI 53532
USA

(608) 846 5467

USA

607 Basset street, DeForest,


WI 53532
USA

(608) 846 5468

USA

Tel: 08456011188

UK

Service

Grease Trap Service

Commercial Kitchens

Containment

Sani Safe

SANI SAFE: System for outdoor grease disposal and storage. Your container is cleaned and
deodorized after each pickup. Large grease screens keep out foreign materials and you only need
one container at your site. Safety features such as leak proof construction, a large opening for
pouring, and a lockable cover make Burbank the safe choice

Burbank Grease
Services

Commercial Kitchens

Microbiological

Grease Buster

The Fragile Earth Greasebuster is an innovative, self contained, eco-friendly solution for maintaining
drains and grease traps in hot food establishments, contains bacteria. Designed to comply with
Building Regulations Part H, it ensures that drain pipes and grease traps are kept free from
blockages arising from fat, oils, greases, and food deposits.

Burdens
Environmental

Drains / Sewers

Chemical

Kitchen Drain Clear

External

Contact Phone No

Rick Thomas

Commercial Kitchens

Physical Separator

Contact Address

Bio-Systems
International

GREASE TRAP SERVICE: Keeping your grease trap in good working order keeps you in business.
Their preventive pumping trap maintenance program helps eliminate untimely problems and costly
emergency pumping services. After each pumping, they leave a compliance report indicating the
general condition of the trap, potential problem areas, and a recommendation for future servicing
frequency.

Commercial Kitchens

Contact Name

BMS Grease Trap

It has been designed to suit the needs of catering facilities large and small, and the food and meat
processing industries. Discharge of grease into sewers causes pipe blockages and hinders the
performance of sewage treatment plants. This range has been designed to suit the needs of catering
facilities large and small, and the food and meat processing industries. (1-8 lps). All Grease Traps are
manufactured from Corrosion Proof Glass Reinforced Polyester (GRP) material, ensuring extended
operation compared to other materials. At the grease trap inlet a solids tray collects food particles
carried in the wastewater. The water is cooled inside the trap allowing the fats and grease to separate
out and rise to the surface.

Buster

Buster
PO Box 7, Ipswich
Suffolk IP7 6DH
United Kingdom

+44 (0)870 6030420

UK

Butler Manufacturing
Services Ltd.

Strokestown Rd.
Longford Ireland

043-26100

Ireland

Location product is
installed / applied

Commercial Kitchens

Product Category

Physical Separator

Product Sub-category Product Name

Website Basic Product related info

External

The GreaseCatcher is compact in design requiring only a small amount of space near the kitchen
sink. The Grease Catcher has a remarkable capacity for its size to remove up to 7.5 litres/day of fat,
oil & grease (FOG).

Grease Catcher

Product requirements

Company Name

Contact Name

Cater Waste

Contact Address

Contact Phone No

Country

Cater Waste
63 Airfield Road
Toomebridge
Co Antrim
Northern Ireland

Sales: 0 28 7965 1888


Services: 028 7965 1990 UK
Fax: 028 7965 1999

BT41 3SQ

Commercial Kitchens

Physical Separator

External

GTS GreaseTrap

Recommended for installation


outside restaurants at an accessible
point, in-ground for ease of
Coalescing filter material separates grease equivalent to tanks that are 3-4 times larger
installation and easy maintenance.
The GTS GreaseTrap has a disposable screening mesh and a removeable holding clamp. (GTS0/1). Note: Grease Traps should be
GTS GreaseTraps have completely removable covers for total access during maintenance. Fits
serviced regularly. Durable, chemical Cater Waste
directly onto the under-ground pipe-work leading from the last kitchen sink. (prior to any foul waste). resistant polypropylene prevents
grease from sticking to it, yet is
lightweight for ease of installation.

Cater Waste
63 Airfield Road
Toomebridge
Co Antrim
Northern Ireland

Sales: 0 28 7965 1888


Services: 028 7965 1990 UK
Fax: 028 7965 2000

BT41 3SQ

Commercial Kitchens

Physical Separator

External

Stainless Steel Grease Traps - a high quality UK manufactured stainless steel grease trap for above
Stainless Steel Grease ground installation. Light weight, easy installation and maintenance unit. Recommended for small
Traps Above Ground
kitchen operations and take-away food preperation operations. Designed for use with biological
dosing and daily emptying by kitchen staff.

Catering Waste
Solutions

Unit 2, Princes Drive,


Kenilworth, Warwickshire, CV8
2FD

1927 853 828

UK

Commercial Kitchens

Physical Separator

External

Stainless Steel Grease A high quality stainless steel grease trap for above or below ground installation. Recommended for
Traps Above or Below medium sized hot food kitchen operations. Catering Waste Solutions recommend our professional
Ground
installation and servicing for this size of unit. Designed for use with biological dosing.

Catering Waste
Solutions

Unit 2, Princes Drive,


Kenilworth, Warwickshire, CV8
2FD

1928 853 828

UK

Commercial Kitchens

Physical Separator

External

Grease Traps Below


Ground

High Density Poly Ethylene (HDPE) grease trap which is designed for below ground installation and
supplied with a single seal galvanised steel cover.

Catering Waste
Solutions

Unit 2, Princes Drive,


Kenilworth, Warwickshire, CV8
2FD

1929 853 828

UK

A pre-programmed, battery operated, peristaltic dosing pump system complete with grease digesting
fluid (up to 6 months supply). The unit is supplied with easy installation kit and instructions.
(Installation prices available) This product package is exclusive to Catering Waste Solutions giving
proven reliable grease control and taking up minimum space in your kitchen. We offer ongoing
support and maintenance free of charge with contracted replacement biological fluid orders.

Catering Waste
Solutions

Unit 2, Princes Drive,


Kenilworth, Warwickshire, CV8
2FD

1930 853 828

UK

Catering Waste
Solutions

Unit 2, Princes Drive,


Kenilworth, Warwickshire, CV8
2FD

1931 853 828

UK

Fatstrippa

Continuous Separation Systems


require daily and weekly
maintenance by kitchen staff. The
The Fatstrippa works by liquids lighter than water rising and escaping by means of a patented valve.
filter basket must be emptied and
Because the fats, oils and greases gather around the valve it is these that are removed as the valve
cleaned daily. The FOGs collected in
opens. Correctly specified the Fatstrippa consistently removes fats, oils and greases to below
the external chamber needs to be
100ppm.
Catering Waste
disposed of responsibly.
Fatstrippa is available in a variety of sizes to suit all commercial or industrial uses.
Solutions
These units also need regular
With a simple install or retrofit, the Fatstrippa does more than just separate fats, oils and greases; it
professional servicing to completely
also strains out solid materials and therefore prevents another major cause of blockages. The system
empty the unit, check over all the
retains settled silts and by means of a simple valve, flushes them away en-mass.
operational functions, clean and
assess the units effectiveness and to
descale the heating element.

Unit 2, Princes Drive,


Kenilworth, Warwickshire, CV8
2FD

1929 853 828

UK

Freeway

Freeway is a liquid formulation of four specifically selected micro organisms which naturally and
Equipment required: dosing meter
safely digest grease, proteins, starch and cellulose. It liquefies, digests and removes organic deposits
for grease traps, hand spray for
from drains, grease traps and kitchen cooker hoods, converting them to harmless compounds of
kitchen hoods.
carbon dioxide and water.

Tony Wood

Gillmans Industrial Estate


Natts Lane
Billingshurst
West Sussex
RH14 9EZ

01403 780638
Fax no: 01403 780639

UK

Inter-X

Inter X It is of vegetable origin and contains no petroleum based ingredients. The absence of
petroleum makes this product particularly suitable for use in foul water drains. Inter-X combines a
powerful odour control in the fast acting and safe solvent to ensure clean degreased drainage
systems and no unpleasant odours.

Tony Wood

Gillmans Industrial Estate


Natts Lane
Billingshurst
West Sussex
RH14 9EZ

1404 780638
Fax no: 01403 780639

UK

Hyzyme

Hyzyme is made up of selective bacteria and enzymes which enhance the natural process of
decomposition. In the form of a fragrant lemon powder, Hyzyme is activated by adding a little water
for a few minutes, or by simply pouring directly down the sink, toilet or drain. Restoring the balance of
friendly bacteria Hyzyme with regular use will; reduce foul odours, digest grease and fat, break down
solids in septic tanks, overcome regular drain blockages due to effluent obstruction and improve
effluent quality.

Tony Wood

Gillmans Industrial Estate


Natts Lane
Billingshurst
West Sussex
RH14 9EZ

1405 780638
Fax no: 01403 780639

UK

Tony Wood

Gillmans Industrial Estate


Natts Lane
Billingshurst
West Sussex
RH14 9EZ

1406 780638
Fax no: 01403 780639

UK

Tony Wood

Gillmans Industrial Estate


Natts Lane
Billingshurst
West Sussex
RH14 9EZ

1407 780638
Fax no: 01403 780639

UK

Commercial Kitchens

Microbiological

Automatic Biological
Dosing System

Commercial Kitchens

Microbiological

Biological Dosing Fluid Digestion solution - Bacteria and enzymes.

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Physical Separator

Microbiological

Microbiological

Microbiological

Chemical

Microbiological

Internal

Citrex

X- IT

This fast acting solvent has a slight citrus fragrance which will not taint treated areas making Citrex
the ideal choice for kitchens and food preparation units. Based on a fully biodegradable aliphatic
solvent, this product is safe as it is not classified as flammable. Citrex is easily rinsed away forming
stable emulsions in water.
Biodegradable and manufactured entirely from vegetable origin, X-it eliminates the pollution
associated with petroleum based alternatives. This fast acting solvent combats the effects of fats,
grease, oil and wax by forming stable emulsions in water, which are easily rinsed away.
This environmentally friendly product is safe to use and suitable for foul water drains. X-it leaves
drains clear of troublesome deposits and free from foul smelling odours.

Chemaide

Chemaide

Chemaide

Chemaide

Chemaide

Location product is
installed / applied

Product Category

Commercial Kitchens

Microbiological

Biosys

Microbiological

Super Chem-ZymeTM V contains fast-acting biological organisms to thoroughly digest organic waste
instead of just pushing it down the waste stream and coats drain walls for extended protection against
drain buildup. Contains no harsh caustics acids or solvents and is non-corrosive. Its active organisms
Super Chem-ZymeTM V
also will not cause disease and are tested salmonella free. Controls odors by eliminating the source
and uses an advanced grease liquefying agent as well as the organisms for fast-acting drain
maintenance. Works with or without oxygen.

Microbiological

Super Chem-ZymeTM V Plus now contains a powerful deodorant as well as an advanced biological
Super Chem-ZymeTM V
concentrate for maintaining grease traps, drain lines, septic tanks, and sewage treatment systems. In
Plus
addition it coats drain line surfaces for maximum retention, digestion, and cleaning activity.

Universal

Universal

Pumping Stations

Microbiological

Product Sub-category Product Name

Contact Address

Contact Phone No

Country

Chemrite International

Kirkleys House, Kirk Langley,


Ashbourne Road, Derbyshire,
United Kingdom.

01332 824848

UK

Chemsearch

Phil Hickman

NCH (UK) Ltd - Chemsearch


2nd Floor, Landchard House
Victoria Street
West Bromwich B70 8ER
United Kingdom

046-9075533
0121 524 7302

UK - USA SPAIN

Chemsearch

Phil Hickman

NCH (UK) Ltd - Chemsearch


2nd Floor, Landchard House
Victoria Street
West Bromwich B70 8ER
United Kingdom

046-9075533
0121 524 7303

UK - USA SPAIN

Pumping station, Biofilter, fat trap etc.

1. Technical Data
a) Description of the problems
caused by the FOG at the works.
Distributors for General Environmental Sciences General Environmental Sciences (GES) has been a b) Daily flow (cu m/day)
leading manufacturer and marketer of bacterial additives for wastewater treatment since 1974.
c) Influent BOD (mg/l)
Products ranging from fat traps to biological treatment.
d) Retention Time at the works prior
to the bio-stage. Details of the size
of any pump chamber and primary
tank will be of

Clarkcomm Ltd

Roger Clark

St. George's House, 14 George


Street, Huntingdon, Cambs,
07747 873713
PE29 3GH

UK

In our Bio-Katz products we have formulated several bacteria strains to essentially degrade waste,
control odours and remove specific unwanted chemicals. In essence the bacteria species are very
effective decomposing and digesting organic material. All bacteria must eat to stay alive. So bacteria
produce Enzymes which break down organic wastes into a liquid form that then can be absorbed by
our bacteria. Subsequently the bacteria convert the absorbed liquids into carbon dioxide and water
which are harmless to our environment. Enzymes are actually catalysts which initiate the chemical
processes involved in digestion. Contrary to popular misconception neither bacteria nor their
enzymes secretions are miniature packmen chewing up waste material. Rather. bacteria are like
sponges that absorb organic waste that has been previously liquefied by enzymes.

Clearwater Services

PO BOX 168, ORMSKIRK, L40


01744 886622
6ZX

UK

Cleveland Biotech

2 Vanguard Court, Preston


Farm Business Park, Stockton01642 606606
on-Tees, Cleveland, TS18
3TR

UK

Grease Separators /
Pumping Stations

Microbiological

Bio-Katz

Commercial Kitchens

Microbiological

Bacnite

Commercial Kitchens

Product requirements

The Biosys - bacteria range of products covers bacteria based cleaning and fat digestion systems.
The Biosys offer the bacteriacide range of products including byclsoan a leading material offering
antiseptic performance. Ingredients Powdered bacterial amylase, neutral proteinase and spore
preparation of Bacillus subtilis

Nutrient solution ideal for enhancing bacterial growth, it includes a variety of biological growth
enhancers.

Company Name

Contact Name

Microbiological

The product contains aerobic, spore-forming bacterial strains belonging to the genus Bacillus. The
total viable count in the ready to use product is not less than 5 x 106 cfu/ml. Amnite L100 is efficient
at digesting fat, oil and grease which tend to build up in fat traps and lead to blocked drains. The
product is best applied with an automatic dosing pump. The product is suitable for use in both
commercial and industrial organisations. The product can be used as a key element of the grease
managment system for a variety of establishments with catering facilities such as fast food outlets,
public houses, hotels, academic institutions and nursing homes. Amnite L100 is also effective in
treating drain blockage in industrial and municipal fat traps and treatment plants.

Cleveland Biotech

Ben Hoskyns,
Tony Brooke

2 Vanguard Court, Preston


Farm Business Park, Stockton01642 606606
on-Tees, Cleveland, TS18
3TR

UK

Microbiological

Amnite L140X is a liquid, biological product which rapidly degrades fat, oil and grease converting
them into simple, environmentally harmless compounds that can not recombine at a later stage.
Therefore unlike chemical alternatives use of Amnite L140X does not merely "move" the problems
elsewhere but eliminates it altogether. The product is completely homogeneous, made from foodgrade ingredients, fully biodegradable and safe to use. It does not contain any pathogens. The
product contains bacterial strains.

Cleveland Biotech

Ben Hoskyns,
Tony Brooke

3 Vanguard Court, Preston


Farm Business Park, Stockton1643 606606
on-Tees, Cleveland, TS18
3TR

UK

Cleveland Biotech

Ben Hoskyns,
Tony Brooke

4 Vanguard Court, Preston


Farm Business Park, Stockton1644 606606
on-Tees, Cleveland, TS18
3TR

UK

Amnite L 100
Commercial Kitchens

Website Basic Product related info

Amnite L 140 X

The product contains aerobic, spore-forming bacterial strains belonging to the genus Bacillus. The
total viable count in the ready to use product is not less than 2.5 x 108 cfu/ml. Amnite L200 in a
janitorial situation is suitable for use in sinks, bathtubs, shower cubicles etc. It is an effective carpet
spotter and can also be used on floors, walls and ceilings. On an industrial level it can be used in
waste disposal sites, land fill sites, transfer stations and waste shutes. The product can be applied
with an automatic dosing pump, fogger, sprinklers or manually by hand, spray bottle or mop. The
product is suitable for use in hospitals, hotels, schools, restaurants and nursing homes.

Universal

Microbiological

Amnite L 200

Universal

Microbiological

Amnite L 240x

Amnite L240X is a liquid, biologically enhanced odour control/surface cleaning agent that can rapidly
degrade everyday organic materials that give rise to offensive odours. The product is completely
homogeneous, perfumed, made from food-grade ingredients, fully biodegradable and safe to use. It
does not contain any pathogens. The product contains bacterial strains.

Cleveland Biotech

Ben Hoskyns,
Tony Brooke

5 Vanguard Court, Preston


Farm Business Park, Stockton1645 606606
on-Tees, Cleveland, TS18
3TR

UK

Other

Consultant

Service

Compliance Consulting, Inc. (CCI) is a leader in the pre-treatment, control and disposal of fat, oil and
grease (FOG). CCI offers a full complement of FOG program planning and policy consulting, code
compliance services, which includes review of codes and regulations.

Compliance
Consulting Inc

Patricia Tripodi,
Philip Soden

Compliance Consulting, Inc.


28 Paine Road
North Attleboro, MA 02760

508.643.4011

USA

COPA

Crest Industrial Estate,


Richard Munden /
Pattenden Lane, Marden,
Joey
Kent TN12 9QJ

01622 833900
01622 833909

UK

Pumping Stations

Microbiological

Bi-Chem 2000 Series


and Bio- Sock

Bi-Chem 2000 Series products have been developed to solve common problems experienced in the
Municipal Sewage Treatment Industry. Bio-Sock is a "loose weave" sock containing bacteria specially
cultured to produce enzymes which digest grease. The floating Bio-Sock works 24 hours a day,
Effective pH 6 - 8.5. Temperature 5
providing cultures are wet and rehydrated. As a result of this enzymatic action, the amount of
-43 C
accumulation at the Pumping Station is reduced or eliminated. We recommend that the station is
Requires continuous dosage
cleaned prior to installing the Bio-Sock. Bio-Sock is a preventative maintenance tool.

Location product is
installed / applied

Product Category

Product Sub-category Product Name

Website Basic Product related info

Product requirements

Bi-Chem 2003 (5lb) for rapid start-up of Biological Treatment Systems.


Bio-Sock 2003 consists of a specially woven fabric sack containing ten strains of patented bacteria. A Effective pH 6 - 8.5. Temperature 5
high strength polypropylene line enables sock to be attached to a suitable fixture. Bio-sock 2003 can -43 C
be used in all types of suspended growth or fixed film biological treatment systems.
Requires continuous dosage

Company Name

Contact Name

COPA

Crest Industrial Estate,


Richard Munden /
Pattenden Lane, Marden,
Joey
Kent TN12 9QJ

Custom Biologicals

Thomas Baugh

Pumping Stations

Microbiological

Bi-Chem 2003 Series


and Bio- Sock 2003

Universal

Microbiological

Custom GT

Its powerful formula is a highly concentrated blend of micro-organisms scientifically chosen for their
enhanced ability to digest the cellulose, lipids, proteins, starches, grease and detergents and other
organic wastes commonly found in grease traps and drain lines.

Other

Service

Service

This company processes the fat, oil, and grease and puts it into other products, such as, ink, rubber,
paint, shoes etc.

DarlingII

Other

Service

Jetting, Rodding,
Electro- Mechanical
Cleaning.

This is a general sewer unblocking company.

Dyno-Rod

Commercial Kitchens

Microbiological

BIOFLOW

BIOFLOW is grease prevention system and maintenance service for drains and grease traps,
supplied and mnaged by Dyno-Rod. The BIOFLOW treatment is a fully automatic process. Integral to
the system is a small wall-mounted pump that is programmed to ensure that a measured dose of
bacteria is discharged daily at a time for maximum effect.

Dyno-Rod

Commercial Kitchens

Physical Separator

ecoGrease

The patent pending grease interceptor, designed according to the newly adopted European Standard
pr-EN1825, separates liquid, coagulating animal and vegetable fat and grease from water prior to
discharge in septic or municipally owned sewer application. (2-10 lps)

BIOAmp

The BIOAmp is a pre-treatment system that produces a concentrated bacterial product, which can be
applied to existing wastewater systems to improve efficiency. The unit is a controlled self-contained,
microbial growth system. This revolutionary system delivers 31 trillion live, vegetative Pseudomonas
and Bacillus bacterial cells every 24 hours at one-tenth the cost of commercially available dry powder
or liquid bacterial formulations. That is the daily equivalent of five 55-gallon drums of readily available
liquid bacterial products or one pail (25 lbs) of dry bacterial product.
By automatically fermenting bacteria onsite, the BioAmp is able to drastically reduce the cost of
biological treatments. This automated system requires no client operator time or attention; all systems
are installed, monitored, and serviced by an ECO Bionics technician.

EcoBug 1

EcoBug 1 is an extremely stable blend of non-toxic natural microbes, which effects FOG and other
organic sewage thus preventing blockages in drainage systems. EcoBug 1 works by liquefying key
elements in FOG etc., allowing the matter to flow away so preventing rotting matter, which can
EcoBug 1: Septic Tanks. To avoid
harbour germs and disease.
time requirements of grease traps.
EcoBug Ltd
EcoBug 1 is demonstrably more effective than chemicals or enzyme treatments as the EcoBugs, like EcoBug 1 pp for immediate reaction
little factories, produce a continuous and renewable supply of highly active enzymes, from within a
bio-film. This film is not washed out because it sticks to the walls of the drainage system.

Universal

Drains / Sewers

Microbiological

Microbiological

Internal / External

EcoBug 1pp is an extremely stable blend of non-toxic natural microbes coupled with lipase enzymes,
which effects FOG and other organic sewage thus preventing blockages in drainage systems.
EcoBug 1pp works by liquefying key elements in FOG etc., allowing the matter to flow away so
preventing rotting matter, which can harbour germs and disease.
EcoBug 1pp is demonstrably more effective than chemicals treatments as the EcoBugs, like little
factories, produce a continuous and renewable supply of highly active enzymes, from within a biofilm. This film is not washed out because it sticks to the walls of the drainage system.

Effective pH 6 - 8.5. Temperature 5


-45 C (28C Optimum). Limit the use
of bleaches and other chemicals

EcoBugs require time to colonise a


site so, to enable the immediate
reaction, EcoBug 1pp is
recommended because the free
lipase enzymes will act instantly
upon the immediate problem whilst
the EcoBugs will carry out long term
maintenance

Contact Address

Contact Phone No

Country

1623 833900
01622 833909

UK

902 Clint Moore Road


Suite #208
Boca Raton, FL 33487 USA

USA

251 O'Connor Ridge Blvd.,


Suite 300, Irving, TX 75038
USA

(972) 717-0300

USA

Richard Swan

Zockoll House,
143 Maple Road,
Surbiton,
Surrey, KT6 4BJ

+44 (0)20 8481-2200

UK

Richard Swan

Zockoll House,
143 Maple Road,
Surbiton,
Surrey, KT6 4BJ

+44 (0)20 8481-2201

UK

Eco Technic

Hrbach 4
A-4673 Gaspoltshofen
Austria

+43 (0) 7735 7320-0

Austria

ECOBionics (Division
Phil Hickman
of NCH UK Ltd.)

2728 CHEMSEARCH BLVD,


IRVING TEXAS 75062

1-866-438-6136
1-866-438-8139

USA

Milton Farm,
Llanteg,
Pembrokeshire
SA67 8PY,
UK

Tel: 01834 831838 or


07000 EcoBug (326284)
Fax:01834 831842

UK

Milton Farm,
Llanteg,
Pembrokeshire
SA67 8PY,
UK

Tel: 01834 831838 or


07000 EcoBug (326284)
Fax:01834 831843

UK

Drains / Sewers

Microbiological

EcoBug 1pp

Commercial Kitchens

Microbiological

ES6

EcoTrap looks like any normal waste trap you would find underneath a sink, however it has some
internal components which allow the slow erosion of a solid bio/enzyme which silently but naturally
consume and digest fats oils and greases.

ECOSAVE

John Ellacott

Unit 8 Rogers Industrial Estate,


Yalberton Road, Paignton,
Tel: 07590 564 640
Devon, TQ4 7PJ

UK

Commercial Kitchens

Microbiological

DDS

Drain Doser is unique and the most effective way to release bio into drainage system without the use
of expensive and problematic pumping systems. The product contains enzymes.

ECOSAVE

John Ellacott

Unit 8 Rogers Industrial Estate,


Yalberton Road, Paignton,
Tel: 07590 564 640
Devon, TQ4 7PJ

UK

Range of products

Supplying Environmentally Friendly & traditional products, chemicals & machinery to meet all our
customers cleaning requirements. EEZYPEEZY are able to supply everything required to clean
whatever the customer needs to clean, on a next day delivery service Micro-organisms eat grease
and fat, to produce water and CO2. Unlike with enzymes the problem is NOT transferred further down
the drain system

Eezypeezy Ltd
Eezytreat

Mr Eric Tindall

6 North Street
Snow Hill Industrial Estate
MELTON MOWBRAY
Leicestershire
LE13 1NL

01664 566 599

UK

Service

Engenica provides operational, maintenance and capital upgrade services for major industrial
organisations throughout the UK and Ireland. We enable our clients to concentrate on their core
business by taking responsibility for non-core utilities assets su

Chris Lambton

Engenica House
Wraysbury Reservoir
Coppermill Road
Wraysbury
Middlesex
TW19 5NW

0800 056 0899

UK

EEC Compliant
Containers

The EEC Compliant Containers & closed loop systems are a clean, convenient and safe method to
handle Waste Cooking Oil. The Containers are custom designed for waste cooking oil and are
suitable for all sites that produce Waste Cooking Oil such as Catering establishments, Hospitals,
Leisure Complexes, Staff Restaurants, Retailers, Hotels, Restaurants etc.

Tel 0 845 009 4287


Fax 0 709 231 0266

UK

GES Grease
Eradication System

The GES is a cost-effective, environmentally conscious system that "remediate's" grease problems
for good. Our state-of-the-art technology harnesses the power of bioremediation, a natural process in
which bacteria actually consume grease and oil from drain lines, grease traps, and interceptors.
These bacteria are non-toxic, non-pathogenic, live, and vegetative. Best of all, they turn grease and
oil waste into harmless carbon dioxide and water. Also provide services in maintenance (disposal) of
grease traps. The system comprises of a reservoir containing a solution of vegetative bacteria, which
remains active 14-days. The solution is dosed into sewer line via peristaltic pump. The system can be
installed in commercial kitchens and the solution dosed into the drain. Also can be dosed into the
sewer line via manholes.

Commercial Kitchens

Other

Commercial Kitchens

Commercial Kitchens

Microbiological

Service

Containment

Microbiological

EcoBug Ltd

Engenica (ThW)

Euro Environmental
Containers

Facility visits by Service Technician


Drain line dye inspection
Treatment of equipment drains with
bacteria
Environmental Biotech Aziz Tejpar, Justin
Treatment of all floor drains with
UK
Price, Bill Hadley
bacteria
Injection system inspection and
maintenance

The Court House


Denmark Street
Wokingham
Berkshire
RG40 2AY
United Kingdom

41 Redhills Road,
South Woodham,
Ferrers,
Chelmsford, Essex,
CM3 5UL

0870 240 6154


07711 752740

UK

Location product is
installed / applied

Product Category

Product Sub-category Product Name

Contact Phone No

Country

42 Redhills Road,
South Woodham,
Environmental Biotech Aziz Tejpar, Justin
Ferrers,
UK
Price, Bill Hadley
Chelmsford, Essex,
CM3 5UL

0871 240 6154


07711 752740

UK

Septic Aid

SEPTIC AID is a powerful septic system and drain line treatment in an easy to use- effectivescent
tablet. It release millions of beneficial bacteria into system. These bacteria enhance the natural
populations and replace those bacteria lost to antimicrobial soaps and other harsh chemicals.
SEPTIC AID should be use in combination with regular septic tank pumping.

43 Redhills Road,
South Woodham,
Environmental Biotech Aziz Tejpar, Justin
Ferrers,
UK
Price, Bill Hadley
Chelmsford, Essex,
CM3 5UL

872 240 6154


07711 752740

UK

Drain Blast
Commercial Kitchens

Microbiological

Website Basic Product related info

Drain Blast degrades organic material in cracks, crevices and drain lines. An easy to use biological
mop water treatment for homes, commercial bars and restaurants.The product contains bacteria.

Product requirements

Company Name

Contact Name

Contact Address

Drains / Sewers

Microbiological

Commercial Kitchens

Physical Separator

Internal

Fat Strippa

Immiscible Liquid Separator able to continuously remove fat, oil, and grease from waste effluent.

Envirocare Systems

Kilcullen Rd., Naas, Co. Kildare

Tel/Fax: 045 874152


Mobile 086 Ireland
8197080

Commercial Kitchens

Physical Separator

Internal

Fat Strippa

Immiscible Liquid Separator able to continuously remove fat, oil, and grease from waste effluent.

Environmental
Innovations

9 Lishanda Manor
Ardclough
Straffan
Co. Kildare

01-6279814

29 Cairn Hill, Newry, Co. Down,


N. Ireland BT342ST
and
Units 6&7 Miltown Close, Tel: 028 3025 7773
Miltown Ind., Estate, Burren,
Warrenpoint, Co. down, N.
Ireland, BT 34 3FN

N.Ireland

Harwell International Business


Centre, 329, Didcot,
Oxfordshire, OX11 0QJ

0870 190 2883

UK

30 Ainseley Grove, Darlington,


Co Durham, DL3 0GD

01325 460040

UK

Ireland

Commercial Kitchens

Physical Separator

Internal

Grease Shield

Protects drains and public hygiene by efficiently removing fats, oils and greases. Whilst removing,
dewatering and transferring solid contaminants for recycling.

Environmental
Products and Services Jim O'Neil
Ltd.

Commercial Kitchens

Physical Separator

Internal

Fat Strippa

Grease separation system connected to sink, induces pressure onto a flowing liquid and then
releasing the pressure by means of a valve

Enviroshield UK

Paul M Finch

Other

Guidance document

Guidance document

Envirowise delivers a valuable government-funded programme of free, confidential advice to UK


businesses. This assistance enables companies to increase profitability and reduce environmental
impact.

Envirowise

Simon Miller

Commercial Kitchens

Physical Separator

Internal / External

Filtra-Trap

Immiscible Liquid Separator able to continuously remove fat, oil, and grease from waste effluent.

Clearflow
Environmental
Technologies Ltd

Commercial Kitchens

Physical separator

Internal / External

Grease traps are designed to separate grease and oil from the wastewater stream.

FC Frost Ltd.

01376 329111

UK

Grease Separators

Microbiological

Dosing units

FC Frost Ltd.

1377 329111

UK

Grease Separators

Microbiological

Biomatic Concentrate

FC Frost Ltd.

1378 329111

UK

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Physical Separator

Physical Separator

Physical Separator

Physical Separator

Physical Separator

External

Internal

Internal

Internal

Internal

Biomatic Grease
Separator

The separated layer from the grease trap is treated with a biomatic bacteria that permanently
converts the grease into an environmentally safe solution that wont re-solidify downstream.
The separated layer from the grease trap is treated with a biomatic bacteria that permanently
converts the grease into an environmentally safe solution that wont re-solidify downstream.
All KESSEL grease separators function using the gravity principle. Wastewater containing grease and
cooking oils enters the separator through a inlet calming device so as not to interfere with the
separations process. Inside the chamber, heavier sludges settle to the bottom while lighter oils and
grease rise to the surface of the separator. The cleansed wastewater then exits the separator and
flows into a public or private sewer system. The collected sludge and grease should be disposed of
monthly by a licensed disposal company. During disposal, the entire contents of the separator are
pumped into a waiting disposal truck and finally the empty grease separator is refilled with fresh water
and placed back into operation.

Fernco Environmental Linda Molly

Endeavour Works, Newlands


Way, Valley Park, Wombwell,
Barnsley, S73 0UW

Tel: 01226340222
Fax:01226340999

UK

KESSEL G free
standing

All KESSEL grease separators function using the gravity principle. Wastewater containing grease and
cooking oils enters the separator through a inlet calming device so as not to interfere with the
separations process. Inside the chamber, heavier sludges settle to the bottom while lighter oils and
grease rise to the surface of the separator. The cleansed wastewater then exits the separator and
flows into a public or private sewer system. The collected sludge and grease should be disposed of
monthly by a licensed disposal company. During disposal, the entire contents of the separator are
pumped into a waiting disposal truck and finally the empty grease separator is refilled with fresh water
and placed back into operation.

Fernco Environmental Linda Molly

Endeavour Works, Newlands


Way, Valley Park, Wombwell,
Barnsley, S73 0UW

Tel: 01226340222
Fax:01226341000

UK

KESSEL D free
standing

All KESSEL grease separators function using the gravity principle. Wastewater containing grease and
cooking oils enters the separator through a inlet calming device so as not to interfere with the
separations process. Inside the chamber, heavier sludges settle to the bottom while lighter oils and
grease rise to the surface of the separator. The cleansed wastewater then exits the separator and
flows into a public or private sewer system. The collected sludge and grease should be disposed of
monthly by a licensed disposal company. During disposal, the entire contents of the separator are
pumped into a waiting disposal truck and finally the empty grease separator is refilled with fresh water
and placed back into operation.

Fernco Environmental Linda Molly

Endeavour Works, Newlands


Way, Valley Park, Wombwell,
Barnsley, S73 0UW

Tel: 01226340222
Fax:01226341001

UK

KESSEL D+S free


standing

All KESSEL grease separators function using the gravity principle. Wastewater containing grease and
cooking oils enters the separator through a inlet calming device so as not to interfere with the
separations process. Inside the chamber, heavier sludges settle to the bottom while lighter oils and
grease rise to the surface of the separator. The cleansed wastewater then exits the separator and
flows into a public or private sewer system. The collected sludge and grease should be disposed of
monthly by a licensed disposal company. During disposal, the entire contents of the separator are
pumped into a waiting disposal truck and finally the empty grease separator is refilled with fresh water
and placed back into operation.

Fernco Environmental Linda Molly

Endeavour Works, Newlands


Way, Valley Park, Wombwell,
Barnsley, S73 0UW

Tel: 01226340222
Fax:01226341002

UK

KESSEL E+S free


standing

All KESSEL grease separators function using the gravity principle. Wastewater containing grease and
cooking oils enters the separator through a inlet calming device so as not to interfere with the
separations process. Inside the chamber, heavier sludges settle to the bottom while lighter oils and
grease rise to the surface of the separator. The cleansed wastewater then exits the separator and
flows into a public or private sewer system. The collected sludge and grease should be disposed of
monthly by a licensed disposal company. During disposal, the entire contents of the separator are
pumped into a waiting disposal truck and finally the empty grease separator is refilled with fresh water
and placed back into operation.

Fernco Environmental Linda Molly

Endeavour Works, Newlands


Way, Valley Park, Wombwell,
Barnsley, S73 0UW

Tel: 01226340222
Fax:01226341003

UK

KESSEL G
underground

Location product is
installed / applied

Commercial Kitchens

Product Category

Physical Separator

Product Sub-category Product Name

Internal

KESSEL E+P free


standing

Website Basic Product related info

Product requirements

All KESSEL grease separators function using the gravity principle. Wastewater containing grease and
cooking oils enters the separator through a inlet calming device so as not to interfere with the
separations process. Inside the chamber, heavier sludges settle to the bottom while lighter oils and
grease rise to the surface of the separator. The cleansed wastewater then exits the separator and
flows into a public or private sewer system. The collected sludge and grease should be disposed of
monthly by a licensed disposal company. During disposal, the entire contents of the separator are
pumped into a waiting disposal truck and finally the empty grease separator is refilled with fresh water
and placed back into operation.
Automatic Grease Removal Unit Traps and Removes Grease, Fats and Oils.
Stage 1 - Solids Collection
Waste water from the kitchen is directed through the inlet of the Grease Guardian where a
removable strainer basket collects any solid debris.
Stage 2 - Grease and Oil Separation
Grease in the waste water floats to the surface and is trapped while the clear water leaves the unit
and enters the drainage system.
Stage 3 - Self Cleaning and Grease Removal
The timer-driven heating element is activated to liquefy grease, which is then removed by the
skimming wheel and deposited into a portable container for recycling.

Company Name

Contact Name

Contact Address

Contact Phone No

Country

Fernco Environmental Linda Molly

Endeavour Works, Newlands


Way, Valley Park, Wombwell,
Barnsley, S73 0UW

Tel: 01226340222
Fax:01226341004

UK

FM Environmental Ltd Olga McNulty

FM Environmental Ltd.
Greenbank Industrial Estate
NEWRY, BT34 2PB, N. Ireland

+44 (0) 28 302 66616

UK

Commercial Kitchens

Physical Separator

Other

Consultant

Service

FM Environmental Limited incorporates a group of business operations, which provide specialist


services to the pump and wastewater treatment industry.

FM Environmental Ltd Olga McNulty

FM Environmental Ltd.
Greenbank Industrial Estate
NEWRY, BT34 2PB, N. Ireland

+44 (0) 28 302 66616

UK

Other

Service

Service

FM Environmental Limited incorporates a group of business operations, which provide specialist


services to the pump and wastewater treatment industry.

FM Environmental Ltd Olga McNulty

FM Environmental Ltd.
Greenbank Industrial Estate
NEWRY, BT34 2PB, N. Ireland

+44 (0) 28 302 66617

UK

Universal

Microbiological

Bacta-Pur
BACTIVATOR

Bacta-Pur BACTIVATORs have been engineered to overcome cost-effectively all of the above
challenges by automatically performing the following operations:
- Grow the bacteria to increase their numbers;
- Physiologically engineer or activate the micro organisms

Global Bio Solutions


Ltd

Marton, Warwickshire, CV23


9SA, UK.

Tel: 01926 633275 Fax:


01926 632750 Mob:
07887 661750

UK

Internal

Goslyn system

It is a liquid separator that significantly reduces the level of fat, oil, and grease (FOG) in waste water
effluent Typical FOG discharge is reduced from 18,500 ppm to 62 ppm.

Goslyn USA Ltd.


1536 Lantern Trail
Frisco
TX 75034
United States of America

+1 214 618 3764

USA

Automatic Grease
Removal Range

The Grease Guardian automatic grease removal system can be installed at source and typically
suits most commercial kitchens. In cases where space is limited the Grease Guardian can be
installed in a basement or adjacent room or kiosk. (0.75 - 3.5 lps)

D1/2 - Pre-Rinse Sink or CombiOven. 230 Volt Power Supply


D2/2 - 1 x Double. Pot wash Sinks.
230 Volt Power Supply
D3/2 - 1 x Double Pot wash Sink &
Combi or Pre-Rinse Sink

Grease Guardian
Products

Anna McNamara

Wareley Road, Woodston,


Peterborough, PE2 9PF

08700 500 012

UK

Manual Grease Trap


Range

The units are ideal for kitchens producing less than 50 meals per day. Each system comes with
connection couplers, solids basket and easy to remove lid as standard.

Small kitchen

Grease Guardian
Products

Anna McNamara

Wareley Road, Woodston,


Peterborough, PE2 9PF

8701 500 012

UK

Food Waste Strainers


And Traps

Solid waste entering grease traps and sewer lines is not only costly to remove but poses an ongoing
threat to our entire sewerage system. Help prevent blockages with IN-SINK DBA and IN-FLOOR DBA
filters. Can be supplied with the Grease Guardian automatic grease interceptor for heightened
performance.

Grease Guardian
Products

Anna McNamara

Wareley Road, Woodston,


Peterborough, PE2 9PF

8702 500 012

UK

Commercial Kitchens

Physical Separator

Commercial Kitchens

Physical Separator

Internal

Commercial Kitchens

Physical Separator

Internal

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Physical Separator

Internal

Physical Separator &


Microbiological

Physical Separator

Physical Separator

Kitchen Biomass
Grease Trap

External

External

The Kitchen Biomass Grease Trap (above-ground installation) is designed for installation inside your
building, it has a smooth, clean, hygienic grey GRP exterior. It can be installed on the floor close to
the sinks or anywhere else convenient to the waste pipes. The standard above-ground units are
supplied complete with an Automatic Biofluid dosing pump and 25 litres of Biofluid (enough to last 5-6
months) There is also an economy range with a Biosock instead of the dosing pump and fluid. All
units are supplied with multi-fit 50mm Osma waste connections.

This range of grease trap is for installation externally, below ground and connected to standard
drainage pipes. Sizes are normally determined by the number of meals per day that the restaurant
Underground Biomass caters for. All units are fitted with 110mm uPVC drainage connections but can be fitted with 160mm
Grease Traps
fittings if requested at time of order.

Lamina Filtertraps

The very high quality of grease and oil separation from these units (better than 25 parts oil per million
parts water). Apart from ensuring that the separation levels are un-surpassed, considerable thought
has been given to the maintenance aspects of the Lamina Filtertrap. With all but the very smallest
size, a mechanical lifting hoist is supplied. This allows the large capacity grease collection trays to be
lifted and suspended above ground level where the valve on the side of the tray can be opened to
allow the oil/grease to drain into a suitable waste container.
If a Garbage Grinder is to be installed in the kitchen, we recommend that the waste from it be run to
enter the drains down stream of the Filtertrap. Alternatively, one size larger Filtertrap may be
specified.

Mike Atkin

Gosyln

Grease Trap
Progressive Product
Developments Ltd

Grease Trap
Progressive Product
Developments Ltd

Grease Trap
Progressive Product
Developments Ltd

Biomass Grease
Treatment
Systems

Dingley Dell House,


24 Beacon Bottom,
Swanwick,
Southampton.
SO31 7GQ

Biomass Grease
Treatment
Systems

Dingley Dell House,


24 Beacon Bottom,
Swanwick,
Southampton.
SO31 7GQ

Biomass Grease
Treatment
Systems

Dingley Dell House,


24 Beacon Bottom,
Swanwick,
Southampton.
SO31 7GQ

Tel: +44 (0)1489-576787


England
Fax: +44 (0)1489-578464

Tel: +44 (0)1489-576787


England
Fax: +44 (0)1489-578465

Tel: +44 (0)1489-576787


England
Fax: +44 (0)1489-578466

Location product is
installed / applied

Commercial Kitchens

Commercial Kitchens

Product Category

Physical Separator

Physical Separator

Product Sub-category Product Name

External

Tanker Emptied
Filtertraps

Website Basic Product related info

Product requirements

The Tanker Emptied Filtertraps are the largest in our range. The oil/grease and sediment storage
capacity is increased considerably in this range. A Sediment separator is included for installation
upstream of the main Filtertrap. If a Garbage Grinder (Macerator) is to be used, increase the size of
Filtertrap by one model or direct the waste from the Grinder down stream of the Filtertrap.

External

Oil Water Separator

Our separators have been independently tested by B.S.IHemel Hempstead, England; L.G.A.
Wurzberg, Germany and C.S.T.B. Nantes, France, the major separator test facilities in Europe. The
EN858 test simulates a rain storm with oil being mixed turbulently into the water before entering the
separator. The outflow from the separator must contain less than 5 parts oil per million part water.
Separators which achieve this standard can normally be placed so that the output flows directly to
streams, lakes and rivers without polluting them. All our separators are approved by the U.K.
Environment Agency and the British Standards Institute.
Poly Trap grease traps can be installed above ground sitting on the floor, or flush to the floor in
concrete. The units are produced in a variety of sizes to satisfy virtually all requirements. Custom
units available up to 300 gpm.
Poly grease traps and grease interceptors are designed and engineered with a specially compounded
material that out performs other plastic materials and steel units in most severe applications

Company Name

Grease Trap
Progressive Product
Developments Ltd

Contact Name

Contact Address

Biomass Grease
Treatment
Systems

Dingley Dell House,


24 Beacon Bottom,
Swanwick,
Southampton.
SO31 7GQ

Biomass Grease
Treatment
Systems

Dingley Dell House,


24 Beacon Bottom,
Swanwick,
Southampton.
SO31 7GQ

Contact Phone No

Country

Tel: +44 (0)1489-576787


England
Fax: +44 (0)1489-578467

Grease Trap
Progressive Product
Developments Ltd

Grease Trap Sales

PO Box 218 Williston, OH


43468 USA

800 476 7930

USA

Grease-o-nator

7041 North Camino Martin, Ste


#121
520-579-1352
Tucson, AZ 85741

USA

Tel: +44 (0)1489-576787


England
Fax: +44 (0)1489-578468

Commercial Kitchens

Physical Separator

External

Poly Trap - Grease


Traps

Commercial Kitchens

Physical Separator

Internal

Grease-o-nator

The unit is easily plumbed into your system with only one 120v/60cy/1ph, 20 amp electrical
connection. The Water Flow regulator is provided with the unit. Once installed FOG are easily
extracted from the wastewater and deposited into the exterior waste container.

Commercial Kitchens

Physical Separator

Internal / External

Ecotec Grease
Extractor S100

The S100 is smaller and lighter than traditional grease traps. It weighs only 28kgs. The S100 is ideal
for difficult site applications, it fits through a doorway, can be installed inside and 1-2 people can lift it.

Halgan

Unit 2, 187 South Creek Road,


Cromer new 2099 USA

02 9972 1355

USA

Pumping Stations

Microbiological

MC 10 Bio-digester,
MC200 Bio-digester

The product contains bacteria and enzymes.

Haulapply Projects Ltd Paul Heath

October Cottage, Main Road,


Little haywood, Staffordshire

Tel 07973391072

UK

Commercial Kitchens

Physical Separator

A high-quality, cost-effective solution to grease separation offering efficient protection systems in


domestic and commercial hot food premises.

Hunter Plastics

Nathan Way
London SE28 0AE

44 (0) 20 8855 9851

UK

Commercial Kitchens

Microbiological

Commercial Kitchens

Drains / Sewers

Physical Separator

Internal

External

Endura Grease
Interceptor
Edura BioPak Dosing
Package

Endura BioPak: is supplied complete with all the necessary fittings, tubing, etc. The product
comprises a mains operated peristaltic programmable dosing pump, 3 litres of Bio-G dual-acting
liquid digesting media (sufficient for 4-6 weeks operation), pre-installed liquid delivery tubing and full
installation instructions.

Hunter Plastics

Nathan Way
London SE28 0AE

45 (0) 20 8855 9851

UK

Oil Separator

Oil / water separators are designed to remove all free and dispersed non-emulsified oil and some
settleable solids from waste streams. If emulsified or dissolved oils are present in the waste water
additional downstream may be required. The principal function of the oil / water separator is to
remove gross quantities of free oil before further treatment. In this capacity, the oil / water separator
protects more sensitive downstream treatment processes from excessive amounts of oil.

Hydro Quip

Hydro Quip Inc.


P.O. Box 3160
North Attleboro, MA 02760

508-695-3640

USA

Victor Franco

+32 2 345 42 53

Belgium

Victor Franco

+32 2 345 42 54

Belgium

Bio-Col

Microbiological

Incoming and outgoing pipe size =


2". Optional inline filter system

Depending of their concentrations in


the environment a specific product
can be adapted to the following
organic pollution : Hydrocarbons,
Since 1996, Idrabel is an European biotechnology company which develops and supplies products to
Petroleum derivatives,Tensioactives, Idrabel
treat all industrial and municipal organic pollution in water and soil.
Dioxins, Organic sulphurs, Nitrogen,
Fats, Cellulose, PCBs, Phenol,
Cresol, Chloro-phenol, Cyanides and
Halogens.
A specific Bio-Epur can also be
adapted to all organic pollution
depending of their concentrations in
the influent of the WWTP:
Hydrocarbons, Petroleum
derivatives,Tensioactives, Dioxins,
organic sulphurs, Nitrogen, Fats,
Cellulose, PCBs, Phenol, Cresol,
Chloro-Phenol, Cyanides and
Halogens.

WwTW

Microbiological

Bio-Epur

Commercial Kitchens

Microbiological

Range of products

IWT is a supplier and designer of bio-augmentation techniques and chemical treatment processes for
urban and industrial wastewater treatment systems.

Industrial Wastewater
Nick Foster
Treatment Ltd

Office 6, Batley Enterprise


Centre, 513 Bradford Road,
Batley, West Yorkshire, WF17
8LL

Commercial Kitchens

Physical Separator

Grease Recovery
Device

The International GRD (Grease Recovery Device) has the newest design in automatic grease traps
that allow recycling of grease and oil. This design will help solve the immense problem of clogged
drain lines and pollution caused from grease and oil.

International GRD

2940 Washington Blvd.


Baltimore, Maryland 21230

410 / 525-0383

USA

APF Pump cleaner

The APF-Cleaner system is designed to control the pump so that it will operate down to the lowest
possible water level in the sump, i.e. down to the level at which air is drawn into the impeller. The
pump will then be able to pump away the grease and dirt that normally always remain on the water
surface. The action of entraining air at low operating depths, also promotes a high level of turbulence
for a short period of the end of the pumping cycle. The turbulence will stir up some of the dirt and
grease that normally collect on the sump floor, and these pollutants will then also be pumped away.
The removal of both floating and settled solids during pumping reduces routine maintenance and
sump cleaning, such as sparging and desludging, and significantly improved pump reliability.

ITT Flygt United


Kingdom

ITT Flygt Ltd


Colwick
Nottingham
NG4 2AN

Tel: 0115 940 0111


Fax: 0115 940 0444

UK

Pumping Stations

Mechanical Device

Internal / External

Idrabel

01924 876750: 01924


422355
Fax 01924 422356

UK

Location product is
installed / applied

Commercial Kitchens

Product Category

Physical Separator

Product Sub-category Product Name

External

The JFC GT01 Grease trap has a capacity of 40litres which mades this trap ideal for dwelling houses.
When the wastewater enters the grease trap, the grease rises to the top and eventually solidifies to
form a hard layer at the surface. The heavier waste solids are deposited in the perforated filtering
bucket, which sits firmly at the bottom of the grease trap chamber.After the wastewater passes
through the filtering bucket it then exits the grease trap through an outlet pipe and continues through
the drainage system. When necessary the filtering bucket can be removed and the grease and
trapped solids can be properly disposed of.

Physical Separator

Commercial Kitchens

Microbiological

Suma Drain GTS Plus degrades organic materials that block drains through the use of nonSuma Drain GTS Plus pathogenic bacteria that break down organic waste into liquid form. It is also highly effective at
eliminating the bad odour that often lingers around drains.

Commercial Kitchens

Microbiological

Suma Drain GTS 1

Commercial Kitchens

Microbiological

Bio-guard

Commercial Kitchens

Physical Separator

Physical Separator

GT01

The JFC GT02 Grease trap has a capacity of 200 litres which made this trap ideal for restaurants,
bars, service station,hotels, fast food outlets etc.
This trap consists of three Chambers:
1. Inlet Chamber: The wastewater flows into the inlet chamber where
the heavier waste solids are retained in the perforated filtering bucket. At this stage some grease may
solidify and rise to the top to form a layer of sludge. There is a baffle to retain any un-trapped solids in
this chamber.
2. Settlement Chamber: The wastewater flows under gravity from the inlet chamber into this chamber.
The settlement chamber acts as a buffer zone where the wastewater will circulate by natural currents
to cool the remaining grease. Then the wastewater flows forward into the outlet chamber.
3. Outlet Chamber: This chamber collects the remaining grease from the wastewater and retains it in
the perforated filtering bucket. The wastewater flows under gravity through the outlet. Again there is a
baffle to retain any un-trapped solids in this chamber.

Domestic Kitchens

Commercial Kitchens

External

GT02

Website Basic Product related info

Product requirements

Company Name

Contact Name

Contact Address

Contact Phone No

Country

JFC Manufacturing
Co. Ltd

Maes Y Clawdd Industrial


Estate
Maesbury Road,
Oswestry, Shropshire, SY10
8NN

Tel: 01691 659226


Fax: 01691 659344

UK

JFC Manufacturing
Co. Ltd

Maes Y Clawdd Industrial


Estate
Maesbury Road,
Oswestry, Shropshire, SY10
8NN

Tel: 01691 659226


Fax: 01691 659345

UK

Johnson Diversey

Siu-lan Chong

Weston Favell Centre,


Northants, NN3 8PD

Tel: 07967694614

UK

Suma Drain GTS1 is a ready to use highly concentrated bio-formulation


designed specifically for the maintenance of grease traps, drains and sewage
pits. The product contains bacteria.

Johnson Diversey

Siu-lan Chong

Weston Favell Centre,


Northants, NN3 8PD

Tel: 07967694614

UK

Liquid biological solution that works 24 hours a day. The system contains micro organisms that
degrade fat, oil, and grease.

Kee - (Formerly
Klargester)

Suru Nathwani

College Road, Aston Clinton,


Aylesbury, Buckinghamshire,
HP22 5EZ

01293 634520

UK

Separation is achieved by reducing the velocity of the incoming liquid in the interceptor causing the
grease to separate from the water and rise to the surface. There it is broken down by Biological
Bacteria allowing the water to flow out of the interceptor into the drainage system.

Tel: +353 53 91 43 216

Internal

GIK 9075

Kent Stainless

Internal

Klargester Grease
Separator

Grease Traps & Separators are most commonly used in catering applications such as pubs and
restaurants. They allow the safe and easy removal of Grease and Fats from wastewater, minimising
problems caused by the unwanted build up of such residue on drainage systems.

Klargester
Environmental Ltd

Bacta-Pur
BACTIVATOR

Bacta-Pur BACTIVATORs have been engineered to overcome cost-effectively all of the above
challenges by automatically performing the following operations:
- Grow the bacteria to increase their numbers;
- Physiologically engineer or activate the micro organisms
The Bacta-Pur BACTIVATORs contain four principal components, which are mounted in a cabinet
of blue rotomolded polyethylene: (1) reservoir for the micro-organisms and nutrients, (2) multi-step
bioreactor, (3) water conditioning system, and (4) electrical controls.

LAS International Ltd


(Bacta-Pur)

David Orme

Less Mess Ltd

Tina Offield
Tina Offield

College Road North, Aston


Clinton,
Aylesbury,
Buckinghamshire,
HP22 5EW

Commercial Kitchens

Microbiological

Domestic Kitchens

Physical Separator

Internal

Fat Trap

Container (500ml) into which you pour your waste oil.

Domestic Kitchens

Physical Separator

Internal

Fat Trap

The New Fat Trap has been developed by Less Mess as a disposable version of the existing Fat Trap
product, based on feedback from customers.

Less Mess Ltd

Roebic - bacterial
drainage treatments

Roebic bio-cleaners for septic tanks & grease traps. The product contains bacteria.

Levermore Workshop
Adrian Griffiths
World

GreasePaK

GreasePaK DMi unit is factory set to automatically deliver a medium dose of


GreasePaK fluid into the kitchen drain each night. Each 28 30 days when the 5L fluid box is
changed, a high boost dose is automatically delivered. During its operational cycle, a simple fluid
level display advises the kitchen operator how much fluid remains. A low-level fluid / empty warning
display will appear when the MSGD fluid box requires replacing. When empty, the box is simply
exchanged for a new refill and connected via a simple unique twist-action quick-connect valve, that
will not allow leakage or liquid loss on change over. The product contains bioenzymes.

Mechline

Fatbuster

Dosing systems and biological products for kitchens. Enzyme producing bacteria (spore forming
bacteria). Fatbuster is a fat digestion system which breaks down the fat and food matter in your waste
pipes, safely. Installed and regularly serviced by Metro

Domestic / Commercial
Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Microbiological

Microbiological

Microbiological

Physical Separator

Domestic / Commercial
Kitchens

Chemical

Commercial Kitchens

Physical Separator

Internal / External

Internal

Metro Rod

Due to location only really available


in Severn Trent and Thames regions.
Dimensions 1 (wheelie bin style)
1020 x 750 x 600 mm Dimensions 2
Miskin Interceptors
(smaller unit) 500 x 600 x 600 mm
Plumbing.1/1/2 inch inlet/outlet pipe.
Adaptor available for larger/smaller
pipe

Miskin Grease Trap

Grease oil Interceptor - maintained by company by taking them away and replacing them fortnightly

Mr Muscle Sink and


Plughole Unblocker

Mr Muscle Sink & Plughole Unblocker is a thick gel specially formulated so that it will not disperse but
instead head straight for the heart of the blockage. Unlike normal bleach it sinks through standing
water until it reaches the blockage and destroys

Mr Muscle

Grease Shield

Protects drains and public hygiene by efficiently removing fats, oils and greases. Whilst removing,
dewatering and transferring solid contaminants for recycling.

Munster Drain and


Environmental
Services

Tel: 0 1296 633000


Fax: 01296 633001

22, Prins Boudewijnlaan


B-2600 Berchem Antwerpen - +32-3-230-9119
Belgium

8 Dunns Close, Wrafton,


Braunton, N Devon, EX33
9 Dunns Close, Wrafton,
Braunton, N Devon, EX33
24 Endeavor Way, London,
SW19 8UH

Ireland

UK

Belgium

01271 817977

UK

1272 817977

UK

020 8946 9882

UK

Peter Galliford

15 Carters Lane, Kiln Farm,


Milton Keynes, MK11 3ER

01908 261511

UK

Andre Hopkins

Metro House
Churchill Way
Macclesfield
Cheshire
SK11 6AY

01625 888100
0 800 668800

UK

Nick Rodgers

Units 3-4, No. 31 Papermill


01213444555 07773
End, Aldridge Road, Great Barr,
310558
Birmingham, B44 8NH

UK

SC Johnson Ltd
Frimley Green
Frimley
CAMBERLEY
Surrey
GU16 7AJ

UK

01276 852000

Tel: 021 4770797


Fax:
0214770877

Location product is
installed / applied

Product Category

Drains / Sewers

Microbiological

Commercial Kitchens

Physical Separator

WwTW

Microbiological

Drains / Sewers

Drains / Sewers

Commercial Kitchens

Commercial Kitchens

Microbiological

Microbiological

Microbiological

Microbiological

Product Sub-category Product Name

Internal

Website Basic Product related info

Product requirements

Company Name

Contact Name

Bio Kat

Bio-Kat is a 100% natural highly concentrated liquid Bio Catalyst that stimulates the aerobic,
anaerobic and facultative bacteria in wastewater.
Its complex formulation increases the cellular metabolism of the bacterial micro-organisms present in
wastewater. It functions by supplying the missing or deficient micronutrients and intercellular enzymes
that are lacking in the nutrient constituent of the wastewater. Bio-Kat addition to wastewater will
potentially lower the BOD, reduce the amounts of FOG and eliminate odours.

Natural Resource
Protection Limited
(NRP)

Rhino Unit

A wet waste interceptor that is fitted underneath sinks.

NCH (UK) Ltd.

Lynne Ratcliffe

BIOAMP

A mini incubator for bacterial dosing that is suitable for larger sites and WwTW.

Dosing carried out up to twice a day. NCH (UK) Ltd.

Lynne Ratcliffe

The Eco-Bio Process is a simple, economic and revolutionary method of accelerating natural
processes for cleaning-up pollution in soils and water.
It uses plant extract material that accelerates the indigenous micro organisms that are naturally
present

The product is supplied in opaque


25-liter canisters. It can be manually
poured down the drain; or it can be
automatically dosed via an
Nimasco
electronically controlled positive
displacement pump that injects the
product directly into the drainage
line.

Eco-Bio Process

Dakarin

The product contains bacteria.

Eco-Swift

Eco-Swift Fat Digester is a state-of-the art system that can be mounted in kitchen drain systems as
a replacement for conventional above ground grease traps. The system receives all kitchens waste
water and liquefies the fats and grease using Bio-Swift Drain Plus Cleaner solution, which is an all
natural plant extract nutrient.

Bio-Swift Drain Plus

Bio-Swift Drain Plus solution is a mixof selected natural plant extracts that accelerates the
liqufication of oil, fats, proteins, strach, cellulose and grease contaminants. The product contains
bacteria and enzymes.

Nimasco

Nimasco

Nimasco

Contact Address

Contact Phone No

Country

329 S. Topeka
Wichita, KS 67202
USA

Tel: 316-303-0505 Fax:


316-303-0506

USA

Lanchard House, Victoria Street


West Bromwich, West
Tel: 0121 524 7310
Midlands, B70 8ER
Lanchard House, Victoria Street
West Bromwich, West
Tel: 0121 524 7311
Midlands, B70 8ER

UK

UK

Amyn S Dahya

Pol.Ind.2a fase # 72 bis,


Alhaurin de la torre, Malaga,
Spain
Building Research
Establishment Ltd
Garston, Watford Herts WD25
7XX

34 952 41 14 39
34 647 664 740
UK
Tel: 044 (0)1923 664630 -SPAIN
Fax 044 (0)1923 664687

Amyn S Dahya

Pol.Ind.2a fase # 72 bis,


Alhaurin de la torre, Malaga,
Spain
Building Research
Establishment Ltd
Garston, Watford Herts WD25
7XX

35 952 41 14 39
34 647 664 740
UK
Tel: 044 (0)1923 664630 -SPAIN
Fax 044 (0)1923 664687

Amyn S Dahya

Pol.Ind.2a fase # 72 bis,


Alhaurin de la torre, Malaga,
Spain
Building Research
Establishment Ltd
Garston, Watford Herts WD25
7XX

35 952 41 14 39
34 647 664 740
UK
Tel: 044 (0)1923 664630 -SPAIN
Fax 044 (0)1923 664687

Amyn S Dahya

Pol.Ind.2a fase # 72 bis,


Alhaurin de la torre, Malaga,
Spain
Building Research
Establishment Ltd
Garston, Watford Herts WD25
7XX

35 952 41 14 39
34 647 664 740
UK
Tel: 044 (0)1923 664630 -SPAIN
Fax 044 (0)1923 664687

Amyn S Dahya

Pol.Ind.2a fase # 72 bis,


Alhaurin de la torre, Malaga,
Spain
Building Research
Establishment Ltd
Garston, Watford Herts WD25
7XX

35 952 41 14 39
34 647 664 740
UK
Tel: 044 (0)1923 664630 -SPAIN
Fax 044 (0)1923 664687

Grease Separators / Septic


Microbiological
Tanks

Septi-Pure

Septi-Pure is a liquid product comprised of natural plant based nutrients and vitamins for odour
control.

Nimasco

Commercial Kitchens

BacTANK T3 TM

An active bacterial/active enzyme technology is used that eliminates the need for harsh chemicals.

Nolan Bio Labs, Inc.

Bio-Kat

Bio-Kat is a Mega concentrate for wastewater treatment, that reduces total suspended solids , odor
reduction, bio-solids reduction and improves effluent, bioremediation of lakes ponds and streams.
Applications of Bio-Activator products have proven to be a complete success and already exist for
Municipalities, Industrial Plants, Pulp, Poultry, Swine and Cattle processing plants.

NRP

2948 NW 60th St.


Ft. Lauderdale, Fl 33309

1-888-633-3444

USA

NRP24DE

The NRP24DE is fully adjustable to regulate dispensing flow rates and can make up to 24 injections
in a 24 hour period. It is battery operated so there is no need to supply electrical hookups. Batteries
will last a minimum of 6 months and are rechargeable. This unit can be fully adjustable using wireless
technology. By utilizing the NRP24DE dosing equipment and Bio-KatTM, any wastewater treatment
facility can eliminate those massive chemical storage tanks now a common eyesore in many
communities throughout the world.

NRP

2949 NW 60th St.


Ft. Lauderdale, Fl 33309

1-888-633-3445

USA

Microbiological

Drains / Sewers / Pumping


Microbiological
Stations

Drains / Sewers / Pumping


Microbiological
Stations

Universal

Drains / Sewers / Grease


Separators

Domestic / Commercial
Kitchens

Microbiological

Microbiological

Chemical

WW07P

WW07L

Oil Lift

WW07P - Powder concentrate for Rapid Grease Removal . WW07P contains a specially formulated
range of adapted high-performance micro-organisms (microbes/ surfactants) developed for use in the
biological wastewater treatment with a high content of greases, fats and oils. As well as microorganisms.
WW07L is specially formulated and packaged for direct addition to drains and grease traps in
restaurants and commercial buildings. WW07L contains microorganisms that are capable of
degrading a wide range of oils and greases under aerobic, facultative and anaerobic conditions,
combined with natural biological enhancers, micronutrients and macronutrients.

Oil Lift is a chemically balanced cleaner and degreasing agent that breaks up oil stains. EcoLogo
certified, Oil Lift meets the highest environmental standards.
When applied to a stained surface Oil Lift starts working immediately, removing 98% of t

NOLAN BIOLABS
P.O. BOX 870631
1-877-246-2847
STONE MOUNTAIN, GA 30087

USA

Oasis Environmental

Oasis Environmental Ltd, Eaton


Tel: 0870 766 8203
Place, 114 Washway Rd, Sale,
Fax: 0161 613 5551
Manchester, M33 7RF

UK

Oasis Environmental

Oasis Environmental Ltd, Eaton


Tel: 0870 766 8203
Place, 114 Washway Rd, Sale,
Fax: 0161 613 5552
Manchester, M33 7RF

UK

Oil Lift

Environmental Building Science


Inc.
100 - 9200 Van Horne Way
604-279-9994 ext 100
Richmond, BC
V6Z 1W3

UK

Location product is
installed / applied

Universal

Product Category

Product Sub-category Product Name

Microbiological

Commercial Kitchens

Containment

Domestic / Commercial
Kitchens

Physical Separator

Commercial Kitchens

Microbiological

Commercial Kitchens

Physical Separator

Formula 33

External

External

Website Basic Product related info

Product requirements

Company Name

FORMULA-33 contains adapted microorganisms specifically formulated for use in municipal and food
production waste-water collection systems. FORMULA-33 is composed of aerobic and facultative
anaerobic microorganisms. These microorganisms have been carefully selected from nature and
adapted for optimum performance in diverse waste streams. FORMULA-33 contains organisms
which produce high levels of lipase, amylase and protease for degradation of grease, fats, oils, starch
protein and cellulose. FORMULA-33 also degrades detergents, surfactants, phenolics, waxes and
hydrocarbons, all of which are present in municipal waste collection systems. FORMULA-33 contains
no added enzymes, wetting agents, emulsifiers or surfactants. FORMULA-33's degradation process
produces harmless water, carbon dioxide and biodegradable microbial protoplasm, a source of food
for higher life forms.

1. Do not add to the treatment


system at a location where toxic or
otherwise adverse pH, dissolved
oxygen or temperature conditions
may exist at peak levels.
2. Application Rates: Consult your
Organica representative prior to use Organica
for specific instructions.
3.
In many cases, it is best used in
conjunction with other fine bacterial
aids from Organica. Consult your
Organica representative with your
specific requirements.

Contact Name

Contact Address

Organica (UK) Limited


4 Sovereign Way
Dock Road
Birkenhead
Wirral
CH41 1DL

Contact Phone No

Country

PHONE NUMBER
0151 653 0253
UK
FAX NUMBER
0151 653 0353

Organic Fat Trap

Dispoable absorbant pouch filled with coconut husk used to absorb waste cooking fats & oils from
grill/fying pans etc.

Organic Absorbents
Ltd

John Black
Geoff Nutland

Nile House
Barkers Business Park
Ripon
HG4 5NB

Tel: 01765 641362


Fax: 01765 641363

UK

Pierre Nortje Fat Trap

The Grease Separator is designed presently to be attached to the outlet pipe from the kitchen. The
kitchen waste water passes into a sealed liner where the F.O.G.S. (fats, oils, grease and solids)
remain in the trap and the clean water is then expelled through an out let pipe in the liner into the
drain.

CapCan Ltd

Pierre Van Nortje

8a New Lane,
Drighlington,
Bradford,
BD11 1NL

Tel: 0113 285 3453

UK

Range of products

The digestion process will be speeded up by catalyzing natural reactions.

Planet Eco

Aly Karim

48 Russell Road, Moor Park,


Middlesex, HA6 2LR

01923 836 649

UK

Aquascreen Grease
Trap

Rapid contaminant removal. Disposable screening mesh and removable holding clamp. Highly
chemical resistant. Optional grease conversion system.

Installation in the drainage pipes


outsidee, approximately 5-15 meters Pollution Control
after the last sink of fixture but prior Products
to joining with any foul waste pipes.

Townsend Bussiness Park,


Belfast BT13 2ES

Tel: 01232 894552


N.Ireland
Fax: 01232 894502

For treatment anywhere grease or fat is a problem. Cleans sewer collection lines, lift station and
septic systems. Reduces pumping frequency in grease traps and septic systems. Reduces septic
tank maintenance costs.

GelPac G must be used with an


Automatic Bacterial Injection (ABI)
Delivery System. This combination
provides the ultimate in product
David Solden/
Unit 13 Knochgriffin Industrial
Polychem Technology
effectiveness, affordability and
Clodagh Grannon Estates, Midelton, Co. Cork
convenience. This combination is so
unique it is patented.

Tel: +353 214633484


Fax: +353
861705080

Ireland

David Solden/
Unit 13 Knochgriffin Industrial
Clodagh Grannon Estates, Midelton, Co. Cork

Tel: +353 214633484


Fax: +353
861705081

Ireland

Polychem Technology

David Solden/
Unit 13 Knochgriffin Industrial
Clodagh Grannon Estates, Midelton, Co. Cork

Tel: +353 214633484


Fax: +353
861705082

Ireland

Polychem Technology

David Solden/
Unit 13 Knochgriffin Industrial
Clodagh Grannon Estates, Midelton, Co. Cork

Tel: +353 214633484


Fax: +353
861705083

Ireland

Universal

Microbiological

GelPac G

Drains / Sewers

Microbiological

GelPac LS

GelPac LS is placed in a flow through bag with attached tether. Tether is tied to post or rail, holding
GelPac LS in place in water. For grease reduction where power/water not available.

Polychem Technology

Grease Separators

Microbiological

GelPac LS2

DOES NOT INCLUDE BAG OR TETHER. Placed directly into influent end of grease trap or directly
into septic systems. Consult GES for best applications procedures.

Universal

Microbiological

LLMO G-1

Used for grease and fat solubilization. Applications include sewage collection systems, wet wells,
grease traps, drain lines and septic tank maintenance. Also for industrial waste with high grease/fat
content.

PS Depth Charge

The Depth Charge is a mixing system that re-suspends floating solids such as fats, oils, and grease
as well as settled solids within a pump station wet well allowing the pumps to remove them. Because
this mixing occurs during every pumping cycle, the solids are kept to a manageable size preventing
any repetitive clogging problems normally associated with pump stations with large amounts of solids.
This mixing is accomplished using a small volume of high pressure air injected immediately before
the pump is energized. This air creates sufficient turbulence within the wet well to mix in the solids
and then exit the water prior to energizing the pumps. The pump is then energized removing the resuspended solids. The entire cycle occurs automatically with no moving parts being added to the wet
well.

Precision Systems

1530 Huntington Drive


Calumet City, Illinois 60409

708-891-4300

USA

Pumping Stations

Mechanical Device

Commercial Kitchens

Physical Separator

Internal / External

Proceptor Grease Model GMC

Fat, oil, and grease interceptor.

Proceptor

202 South Tryon Street, Suite


1475
Charlotte, NC, 28202 USA

704-295-1734

USA

Commercial Kitchens

Physical Separator

Internal

Retroceptor

The Retroceptor is a high-performance, beneath-the-sink grease interceptor that offers wastewater


treatment at the source for restaurants, institutions, manufacturers and other food service industry
businesses.

Proceptor

203 South Tryon Street, Suite


1475
Charlotte, NC, 28202 USA

704-295-1735

USA

Proviro

5 Castaheany
Navan Rd.
Dublin 15

01-8202189

Ireland

Big Dipper Internal Strainer (IS) series units utilize an internal strainer basket to capture incidental
solids in kitchen waste water flows. A skimming wheel system inside the unit skims the grease & oils
out of the retention area when activated by a programmable timer. IS units work well inside fast foodtype restaurants or food preparation facilities where grease removal directly at the source is
important. Big Dipper IS Point Source Grease Removal Units treat kitchen flows of 15 to 50 gallons
per minute. There are also larger Grease Removal Units in the IS category that pretreat wastewater
flows of 75 and 125 gallons per minute.

Commercial Kitchens

Physical Separator

Internal

Internal Strainer
Basket Systems

Commercial Kitchens

Physical Separator

Internal

Central Grease
Removal Units

Big Dipper Point Central Grease Removal Units treat kitchen drain flows of 75 & 125 GPM. These
units are designed to treat flows from multiple fixtures in a central location like a basement or
mechanical room. Big Dipper Central Grease Traps are typically found in higher flow installations like
hospitals, casinos, correctional facilities and hotels.

Proviro

6 Castaheany
Navan Rd.
Dublin 15

01-8202190

Ireland

Commercial Kitchens

Physical Separator

Internal

Point Source Grease


Removal

Big Dipper Point Source Grease Recovery Units treat kitchen drain flows of 15-50 GPM (0.95-3.15
l/s). These units are designed to treat single fixtures such as a three compartment sink or pre-rinse
station. Big Dipper Point Source Grease Traps are typically found in fast food & full-service
restaurants, delis, rotisserie ovens, schools, grocery stores and similar establishments.

Proviro

7 Castaheany
Navan Rd.
Dublin 15

01-8202191

Ireland

Location product is
installed / applied

Product Category

Product Sub-category Product Name

Trapzilla Grease Trap


Systems

Website Basic Product related info

The Thermaco, Inc. Trapzilla Supercapacity Grease Trap collects free-floating (non-emulsified)
grease & oils contained in kitchen drain water flows. Grease buildup inside a buildings grease
containment system is a major cause of problems due to exterior drain line blockages. These
problems jeopardize normal operations as well as create health and safety hazards within the facility
itself. Proper installation of a Trapzilla Supercapacity Grease Trap can reduce or eliminate grease
problems. Use of a Trapzilla system assures minimization and/or elimination of costly sewer
surcharges and fines through efficient separation and retention of free-floating grease & oils.

Commercial Kitchens

Physical Separator

Internal / External

Commercial Kitchens

Physical Separator

Internal

The Big Dipper FSH Horizontal Flow Splitter Module splits a single effluent flow exiting a kitchen
Horizontal Flow Splitter
into two separate, equal flows in large institutional-type installations or for sites that need central
Module
grease removal but have a small footprint.

Commercial Kitchens

Physical Separator

External

PSI separator

Domestic / Commercial
Kitchens

Physical Separator

Drains / Sewers / Grease


Separators

The engineers of PSI have 20 years experience designing high performance and low maintenance
oil-water separators. PSI offers a wide range of separator sizes and configurations.

Product requirements

Company Name

Contact Address

Contact Phone No

Country

Proviro

8 Castaheany
Navan Rd.
Dublin 15

01-8202192

Ireland

Proviro

9 Castaheany
Navan Rd.
Dublin 15

01-8202193

Ireland

PS International

5309 E. Ryan Place


Sioux Falls, South Dakota
57110

605-332-1885

USA

Its position in relation to the Kitchen/


Source is important as it is
necessary to allow the material to
PVC Fabrications
cool (approximately 40C) thus
(Sales) Ltd.
enabling the separation process
(about 4 m from the source is
recommended).

Contact Name

Cullinanes Cross roads


Ballynagrumoolia,
Briar Hill, Waterfall
Near Cork

PVC Grease Trap

PVC Grease Traps greatly reduce incidents of drain blockages from catering facilities as well as
domestic operations.

Microbiological

Grease Buster

Grease buster is an innovative, self contained eco-friendly solution for maintaining drains and grease
traps in hot food establishments. In addistion to maintaining drains the bacteria also eradicates foul
smelling odours that often emanate from drains in food establishments. The product contains
bacteria.

Pulsonic Bioscience

Riverside House, North Dean


Business Park, Stainland Road, Tel: 01422 363462
Greetland, Halifax, West
Fax: 01422363275
Yorkshire, HX4 8LR

UK

WwTW

Microbiological

MICROCAT - SXM

MICROCAT-SXM is a synergistic blend of preselected, adapted micro-organisms and enzymes for


use in sewer systems, lift stations and biological wastewater treatment plants receiving municipal and
food processing waste and for use in aerobic and anaerobic sludge digesters.

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701370

Netherlan
ds
(Holland)

Drains / Sewers / Grease


Separators

Microbiological

MICROCAT - DNT

MICROCAT-DNT is a synergistic blend of preselected, adapted micro-organisms for liquefying


greases and fats and maintaining plumbing systems free of blockages. MICROCAT-DNT also
contains enzymes and additional synergistic ingredients for keeping drains and traps clear and freeflowing.

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701371

Netherlan
ds
(Holland)

Microbiological

MICROCAT-DNTHT is a synergistic blend of preselected, adapted microorganisms for liquefying


greases and fats (FOG) and maintaining plumbing systems free of blockages. MICROCAT-DNTHT
MICROCAT - DNTHT also contains specialized heat-tolerant microorganisms for controlling odors FOG accumulations
where hot water conditions are frequent in the drains, traps, lift stations, etc. It also contains enzymes
and additional synergistic ingredients for keeping drains, traps and lift stations clear and free-flowing.

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701372

Netherlan
ds
(Holland)

Drains / Sewers / Grease


Separators

Microbiological

MICROCAT-DNTTH is a synergistic blend of preselected, adapted microorganisms for liquefying


greases and fats and maintaining plumbing systems free of blockages. MICROCAT-DNTTH also
MICROCAT - DNTTH contains specialized microorganisms for controlling odors associated with FOG accumulations and
inadequate grease traps. It also contains nzymes and additional synergistic ingredients for keeping
drains, traps and lift tations clear and freeflowing.

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701373

Netherlan
ds
(Holland)

Universal

Microbiological

MICROCAT - ECL

MICROCAT-ECL is a liquid blend of natural enzymes and surfactants for use in cleaning and
deodorizing. It is formulated for use in a wide range of applications from food processing to
wastewater treatment to enhance cleaning and removal of fats, oils, greases, starches, proteins, etc.
and to suppress the odors resulting from such compounds.

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701374

Netherlan
ds
(Holland)

Drains / Sewers / Grease


Separators

Microbiological

MICROCAT - GEL

MICROCAT-GEL is a liquid blend of natural bacteria, enzymes and surfactants for use in maintaining,
cleaning and deodorizing. It is formulated for ease of cleaning and removal of fats, oils, greases,
starches, proteins, etc. which accumulate in toilets, drains, traps, plumbing systems and septic tanks
and to suppress the odors that result from such accumulations.

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701375

Netherlan
ds
(Holland)

QM Environmental
Services Ltd.
(Formerly: QM
Bioscience)

De Vlinderhoven 68 - 3124 BT
SCHIEDAM - The Netherlands

31(0)104701376

Netherlan
ds
(Holland)

Drains / Sewers / Grease


Separators

Internal

Glen O'Callaghan

353 87 2613159

Ireland

Drains / Sewers / Grease


Separators

Microbiological

MICROCAT - SMAL

MICROCAT-SMAL is a concentrated liquid cleaning compound containing microbes, cleaners and


enzymes. It is formulated to wet, lift and emulsify animal and vegetable fat, oil and grease (FOG)
deposits on hard surfaces such as concrete, macadam or in drain pipe interior walls and floors.
MICROCAT-SMAL contains ecialized naturally-occurring microbes in dormant form. When activated
by applying them to FOG, the microbes are capable of digesting and deodorizing the FOG deposits.

Commercial Kitchens

Containment

Fat Trapper

The Fat Trapper is a plastic, airtight container that holds a foil lined bag. Simply pour hot cooking
grease into the bag, seal, and replace the lid. It eliminates spills and odours, while protecting your
residents' plumbing system.

Special Accounts Manager,


419-331-8000
Range Kleen Mfg. Inc. Jackie Schroeder Range Kleen Mfg. Inc, PO Box
1-888-391-2020
696, Lima, OH 45802, USA

Commercial Kitchens

Containment

Storage Cabinets

A robust galvanised steel cabinet providing safe, secure, dry and out of sight storage designed to
meet oil storage regulations and best practice.

Ri Manufacturing Ltd

Pippa Fordham

Chapelbarn Yard, Wylye,


wiltshire BA12 0QQ

01985 248454

Pumping Stations

Microbiological

Bacta-Pur Bactivator

Rockbourne
Environmental Ltd.

Angus Marland

6 Silver Business Park, Airfield


Way, Christchurch, Dorset,
BH23 3TA

Tel: 01202 480980


UK
Fax: 01202 490590

However, in a permanent installation


the switching may be done by wiring
into the pump control panel. But for
trials purposes a simple garden
Rodney Perrigo Ltd
watering timing device could be
used.
A potable water supply is required on
site.

Rodney Perrigo

Pumping Stations

Mechanical Device

Auto Well Washer

The Bacta-Pur Bactivator assures the continual presence of an optimal community by seeding
specific organisms to accomplish a particular task, for example the biological removal of grease, or
cleaning sewers.

Auto wet well washer system Eliminates Fat : uses as little as 100 litres of water per day to keep well
walls and components fat free. No more manual cleaning. Easy to install. The McBerns Auto Well
Washer is an automatic well washing system for sewage pumping stations. The system comprises a
cleverly designed rotating spray device. The spray device has two arms with special nozzles, which
are directed at the wet walls and components.

01327 860787

USA

UK

UK

Location product is
installed / applied

Product Category

Grease Separators

Microbiological

Biokleer

"Biokleer is a liquid product that contains natural cultures, selected specifically to attack grease and
fat deposits. These cultures release active enzymes to degrade and digest the fats and oils in grease
traps - before they get a chance to cause problems

Commercial Kitchens

Physical Separator &


Microbiological

OILiminator

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Commercial Kitchens

Domestic / Commercial
Kitchens

Physical Separator

Product Sub-category Product Name

External

Oil Separation
Modules

Website Basic Product related info

Contact Address

Contact Phone No

Country

Scotmas Limited

Spylaw Road
Kelso, Borders
TD5 8DL
Scotland

+44 (0)1573 226901

UK

The only approved bio-mechanical oil water separator system, a complete pollution-prevention
solution for bilge water, the OILiminator is a USCG and International Maritime Organization (IMO)
approved oily water separator (OWS) that easily handles phase-se

Skimoil, Inc.

P.O. Box 6042


Chesterfield, MO 63006-6042

(314) 579-9755

USA

The Spinifex oily water separator works on a very simple hydrocyclone principle. Oily water treatment
is achieved by pumping the mixture tangentially into the oil water separator. This initiates a spinning
vortex which is accelerated as the water is forced down the tapered section, separating the heavier
water phase to the outside wall while the lighter oil phase moves to the center. The separated oil is
removed through a reject orifice located in the inlet head and the treated water is discharged through
the opposite end.

Spinifex

12 Heysen Grove, Doncaster


East
VIC, 3109, Australia

(61-3) 98427960

Australia

Serious Waste
Management Ltd

Serious Waste Management


Ltd
58-60 Wetmore Road
Burton-upon-Trent
Staffordshire
DE14 1SN

01283 562382

UK

Swan Enviro

Simon Nicholas

10, Engine Road


Loanhead,
Edinburgh EH20 9RF

1314403812 UK

Swan Enviro

Simon Nicholas

10, Engine Road


Loanhead,
Edinburgh EH20 9RF

1314403813 UK

Microbiological

Grease Guzzler

Usually once a day, at a regular pre-programmed time, the Grease Guzzler dilutes , heats and
activates a mix of bacteria and enzyme strains which are released (dosed) into the drainage system.
The solution digests grease, cooking oils and animal fats, deg

Microbiological

Swan Freshflo
Dosing units

Stainless steel housing for easy wipe down and long life in a tough kitchen environment. Wall
mounted, so it is easy to fit out of the way and convenient for refilling the fluid. Battery powered unit
option to suit location without wiring.
Ideal for retro-fit. Full maintenance instructions supplied with the unit.
2 year return to base warranty.

Physical Separator

Internal / External

Microbiological

Microbiological

Swan Freshflo
Grease Traps

Swan Grease Traps are available in a range of sizes to suit every application, from the compact
GT05 for domestic use up to the extra high capacity GT200M for industrial multi-sink use.
Internal or external use (above ground). Through flow
unit, serves any sink/dishwasher volume where recommended installation and cleaning procedures
are followed. High quality type 304 stainless steel. All seams fully welded.
Connection using standard Multi-fit connectors. Quick release watertight lid for simple inspection and
cleaning. Integrated access for grease reliquifier (if specified). Full maintenance instructions supplied.
2-year return to base warranty.

Product requirements

Company Name

Contact Name

Symbio

Symbio
38 Bookham Industrial Park
Church Road
Great Bookham
Surrey
KT23 3EU

44 (0) 1372 456101

UK

Symbio

Symbio
38 Bookham Industrial Park
Church Road
Great Bookham
Surrey
KT23 3EU

46 (0) 1372 456101

UK

47 (0) 1372 456101

UK

056-7763932

Ireland

Symbio Liquid Drain


clean

Symbio Liquid Drain Clean digests and degrades fats due to the action of selected microorganisms
(bacteria and enzymes). The digestion prevents the fermentation of anaerobes, the source of bad
odours and pollutants, and so has a deodorising effect. The microorganisms also enhance the
functioning of sewage treatment plants.

Grease Buster

Action Grease Buster contains microorganisms (bacteria and enzymes) specially selected for their
ability to rapidly break down animal and vegeatble fat and grease. They are fixed to a protective
mineral support, which sticks to the grease in the trap and rapidly degrade it into its basic mineral
elements, water and gas.

Symbio

Symbio
38 Bookham Industrial Park
Church Road
Great Bookham
Surrey
KT23 3EU
Canices Court
Dean St.
Kilkenny Ireland

Drains / Sewers

Microbiological

Darain Clean

Symbio Drain Clean contains microorganisms (bacteria and enzymes) fixed to a proactive mineral
support. They feed on waste matter in the drain and break it down into its basic mineral elements,
water and gas. This natural action degrades your waste and prevents noxious odours. Drain Clean
also enhances the action of effluent treatment plants.

Commercial Kitchens

Service

Service

Service offered - removing grease removal

Treatment Systems
Ltd.

Commercial Kitchens

Physical Separator &


Microbiological

Actimatic Grease
Converter

The Atimatic Grease Converter works in 2 stages:


1) Separation - effluent entering the converter passes over a hydrafilter baffle which causes grease
to form in globules which float to the surface.
2) Digestion - achieved by Wade Actimatic which

Wade International
Ltd.

Other

Guidance document

Guidance document

Guide to advise catering establishments on best practice for disposal of food waste and the need to
keep fat, oil and grease out of drains and sewers.

Water UK

Commercial Kitchens

Physical Separator

Internal

Big Dipper

Commercial Kitchens

Physical Separator

Internal

Internal Grease Traps

The Big Dipper does this by first trapping grease & oil using a baffled tank and then at a preprogrammed time it activates a semi-submerged skimming wheel which skims the collected oil into an
external flask for manual disposal.
To prevent grease entering the drainage system Watling Hope supply a range of floor standing
stainless steel grease-traps. Constructed in high quality stainless-steel the units are available in a
variety of sizes to be used with pot wash sinks, pan wash sinks and dishwashers.

UK

Phill Mills

020 7344 1809

UK

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

Location product is
installed / applied

Product Category

Product Sub-category Product Name

Commercial Kitchens

Physical Separator

External

Commercial Kitchens

Microbiological

Pumping Stations

Microbiological

Website Basic Product related info

Watling Hope supply a range of external below ground grease separators for the interception of fat,
External Grease Traps oil and grease. Constructed in GRP or High Density linear polyethylene and ranging in size from 150
to 50,000 litres whatever your requirement we have a grease interceptor to suit.

Product requirements

Company Name

Contact Name

Contact Address

Contact Phone No

Country

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

Grease Guzzler

Wall mounted the Grease Guzzler works by automatically preparing and then releasing a solution of
grease digesting micro-organisms (bacteria and enzymes) into the drainage system. The solution
digests grease accumulations and forms a natural culture to prevent further deposits.

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

BioCake Sump
Treatment

The Watling Hope BioCake is a 'cake' of powdered micro-organisms (bacteria and enzymes) held in a
dormant spore state. The product is suspended in a sewage pump well where on contact with effluent
it activates and releases enzymes and bacteria which digest fat, oil and grease build-up. Located
within the well itself the BioCake continually releases grease degrading micro-organisms - providing
ongoing protection 24 hours a day. Frequency of replacement depends on the size of sump and is
typically between 2-3 months. The WH BioCake can be replaced by onsite maintenance engineers
or by Watling Hope as part of an automatic replacement programme.

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

The BioActive Drain Treatment System is a fully automatic biological drain treatment system which
digests grease build-up and prevents odours.
Installed at the point at which the greasy effluent enters the line the BioActive DTS automatically unit
injects a high performance biological formula which controls grease build-up. The systems small size
and battery operation mean that it can be installed virtually anywhere and can be used to treat grease
from pot wash sinks, combi ovens and rotisseries. The products contains bacteria and enzymes.

Commercial Kitchens

Microbiological

BioActive DTS

Commercial Kitchens

Microbiological

Grease Goblin

Grease Goblin system automatically delivers a measure of biological fluid containing specially
cultured bacteria and enzymes into the drainage network, after the kitchen is closed each night. The
bacteria and enzyme work together to attact grease deposits in the drain line and form a living culture
within the pipework to provide protection 24 hours a day.

Watling-hope

1 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

01789 740757

UK

Commercial kitchens

Microbiological

Mini Guzzler

Mini Guzzler mixes a unique, naturally- formulated biological compound into a solution that effectively
Single phase electrical supply, fused
'sweeps' drain pipes clean. The fluid not only prevents grease from sticking to the clean pipes, but
Watling-hope
at 2 amps and cold water supply.
also leeches simultaneously into any existing deposits, attacking and forcing them off.

2 Goldicote Business Park,


Stratford-Upon-Avon,
Warwickshire, CV37 7NL

1790 740757

UK

Edlington Lane
Edlington
Doncaster
South Yorkshire
DN12 1BY
United Kingdom

Tel: 01709 856300


Fax: 01709 856301

Commercial Kitchens

Commercial kitchens

Physical Separator

Microbiological

External

UNIV GREASE TRAP


COMPLETE L

Grease Trap

GREASE GUZZLER

GREASE GUZZLER employs patented processing to activate and condition a unique, naturally
formulated biological compound. Once the effectiveness of this bio-fluid has been fully optimized,
against a pre-set time-schedule, GREASE GUZZLER releases it into the drainage system, where its
presence rapidly accelerates grease degradation.

The system is not affected by the


normal use of kitchen equipment
Wendage Pollution
such as dishwashers, or by bleaches Control Ltd
and cleaning agents etc.

Wendage Pollution Control


Limited
Rangeways Farm, Conford,
Liphook
Hampshire, GU30 7QP

01428-751296

UK

The system is not affected by the


normal use of kitchen equipment
Wendage Pollution
such as dishwashers, or by bleaches Control Ltd
and cleaning agents etc.

Wendage Pollution Control


Limited
Rangeways Farm, Conford,
Liphook
Hampshire, GU30 7QP

01428-751297

UK

Commercial kitchens

Microbiological

MINI GUZZLER

GREASE GUZZLER employs patented processing to activate and condition a unique, naturally
formulated biological compound. Once the effectiveness of this bio-fluid has been fully optimized,
against a pre-set time-schedule, GREASE GUZZLER releases it into the drainage system, where its
presence rapidly accelerates grease degradation.

Drains / Sewers / Grease


Separators

Microbiological

BIOAmp

The product contains bacteria and enzymes. BIOAmp was primarily developed for grease traps, drain
lines and interceptors and this is where it works best.

Wavin

White Rock
Consultants

Rod Thornhill

UK

RETURN TO DATABASE

Company Name: Advetec Ltd.


Trial No

Product

Location

Advetec 100

Pumping Station

Advetec 100

Drains / Sewers

Description
The pumping station had historically suffered from excessive
build up of fats, oils and greases. The site was being cleaned
every three months to remove the excessive FOG build up. The
product was dosed directly into the pumping station.
The product was dosed into the drain/sewer system of a food
processing factory to remove FOG build up.

Results
It was noted that the dosing is having a
noticeable effect as there have been no
reported odours and the build up of FOG
has been significantly reduced.
Noticeable reduction in FOG build up.

RETURN TO DATABASE

Company Name: Aluline Commercial Drainage Specialists


Trial No

Product

Location

AG2 300

Commercial
Kitchen

BioBlock, Alubio
"L" Block

Drains / Sewers

BioBlock, Alubio
"L" Block

Drains / Sewers

nage Specialists
Description
Without biological teratment the trap was cleaned every two weeks. Once
the biological dosing was initiated, the maintenance interval was extended
to 6-8 weeks.
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged via the
sink.
An initial CCTV survey was carried out which showed a heavy build up of
FOG in the drain/sewer.

The public sewer at rear of the row of properties regularly blocks with FOG,
causing lack of toilet use and internal flooding at the properties. The sewer
has a flat gradient which exacerbates the problems caused by FOG
discharges from local catering premises. A Chinese takeaway is thought to
be the main source of FOG. It is believed that the premise has general bad
practices relating to the disposal of waste fats and oils, and it is thought that
these are disposed of directly via a manhole outside their property. The
sewer was cleaned prior to installation, therefore the product was acting to
prevent FOG accumulation. A single Alubio L block (a specialised slow
dissolve block which attacks fats, oils and grease) was suspended inside
the manhole in the wastewater flow.

Results
Feedback from the properietors was positive
regarding the kitchen practice and grease trap
maintenance guidance sheets.

The BioBlock performed quite well. Although it did


not keep the pipework clean, the (reported)
blockage rate was greatly reduced. The FOG that
did build up in the pipework appeared to be softer
in texture and may have been more easily
removed using high pressure jetting.
The amount of fat being discharged at this location
appears to be greater than first thought, therefore
it was difficult to determine the effectiveness of the
product at this location.

RETURN TO DATABASE

Company Name: APPS Ltd.


Trial No

Product

Location

Bio Treat 2000

WwTW

Bio Treat 2000

WwTW

3
4

Bio Treat 2000


Bio Treat 2000

Pumping Station
Pumping Station

Bio Treat 2000

Pumping Stations
& Sewers

Description
FOG entering the works affects the primary settlement tanks
causing blockages and forming excessive deposits on the
surface of the tanks. Daily removal of FOG from tanks
requires 4 man-hours of time. The sludge line from the
primary tanks is jetted to remove FOG accumulation every 3
months, a 2-days job for a jetter and tanker.

FOG deposits cause problems throughout the treatment


process, particularly within the sludge thickening tanks and
pipework, causing blockages and valve failure.
The system was installed at the inlet to the treatment works
and is still in operation.
No record included in the report
A pumping station with low flows, and a large FOG problem.
The size of the rising main coupled with the low flows meant
that it could take up to four days for the sewage to reach the
end of the rising main. This lead to odour complaints from
the gravity sewer section beyond the rising main, and
problems with corrosion both on the rising main and the
gravity section following it.
Sites suffered from either odour or FOG problems. Biotreat
was dosed into the wet well of each the pumping station or
straight into the sewer via manholes.

Results
The FOG build up at the treatment works is still significant,
however, the deposits are softer and easier to remove.
The system has continued to be in operation,since the trial in
2003.
The way the system is operated at this site is not as the
suppliers would recommend, hence the results obtained during
this trial may not be as good as is possible with this system.

A reduction in the thickness of the fat deposits on the inlet


channel walls was noted.
The frequency that the sludge thickener pipework is jetted has
been reduced from monthly to 3 monthly intervals.
Changes in operational and maintenance tasks at the works
have also helped to reduce costs.
No results included in the report
Biotreat was dosed into the wet well of the pumping station, and
according to the contractors, turned the thick, hard, black crust
of FOG to a much thinner, softer layer. Odour complaints at this
site have also stopped since the start of the dosing.

Evidence suggests that there have been no subsequent odour


complaints, and the FOG problem is much reduced at all sites.

RETURN TO DATABASE
Company Name: Aquazur UK Ltd (PermaCare International)
Trial No
1

Product

Location

Envirofloc GD Commercial
Kitchen

Description

Results

The main reason behind the premature operation of a CSO was found to be the
A significant reduction in the number of fat
presence of fat and silt blocking the throttle pipe. CCTV surveys in the area were carried related sewer blockages.
out to confirm the presence of fat and identify the likely source (an army barracks).
A decision in the 1970's meant that the army barracks grease separator had been
removed due to its high maintenance cost.
Substantial quantities of fat were discovered in the public sewer downstream of the
army barracks, therefore it was recommended that either the grease separator was reinstated or a biological dosing system was installed.
The Aquazur system was subsequently installed in the kitchens at the army barracks.

RETURN TO DATABASE
Company Name: BioClear Environmental Services Ltd
Trial No

Product

Location

Bio Clear

Pumping Station

Bio Clear

Pumping Station

al Services Ltd
Description
The product has been used since 2001 to overcome fat
build up in the wet well. The fat:
caused blockages in the pumps;
caused odour problems; and
prevented the operation of float controls.
The product has been used since 2001 to overcome fat
build up in the wet well. The fat:
caused blockages in the pumps;
caused odour problems; and
prevented the operation of float controls.

Results
The fat turned into light spongy layer on surface of effluent in wet
well.
Dosing at the wet well was also beneficial to rising main, the
downstream gravity sewer and the treatment works. It has also
reduced cleansing costs.
The fat turned into light spongy layer on surface of effluent in wet
well.
Dosing at the wet well was also beneficial to rising main, the
downstream gravity sewer and the treatment works. It has also
reduced cleansing costs.

RETURN TO DATABASE
Company Name: BRE
Trial No
1

Product
Eco-Bio 608

Location
Pumping Station

Description
The pumping station has a long history of heavy FOG
accumulation, which forms into a thick crust affecting the
operation of the floats, pumps and other monitoring
equipment.
Regular wet well cleaning and tankering of the contents
was the only way to deal with the problem.
Prior to the trial the pumping station wet wall had a 4-6
month old, solid dry crust approx 300mm thick. The
volume of this crust was estimated to be 3.6m3.

Results
Upon application of the solution the surface of the crust the
sewer system operators noted that the crust appeared to visibly
break down almost immediately.
Estimates indicate that around 65% of the crust was removed by
microbial action or broken up sufficiently to pass through the wet
well without causing problems.
One week after the initial application the remaining FOG crust
had formed a layer of small round balls 15 mm thick, with
approximately 25% of the surface of the wet well as clear water.

RETURN TO DATABASE
Company Name: Chemaide
Trial No
1

Product
Freeway

Location
Pumping Station

Description
The product was applied to a pumping station with
known FOG problems for a 3 month period.

Results
The product appeared to work at first but there was deemed to
be no real benefit.
The problem was subsequently tackled at the source of the
FOG discharge rather than at this pumping station.

RETURN TO DATABASE
Company Name: Chemsearch
Trial No

Product

Location

Super
Pumping Station
Chemzyme IV

Super
Pumping Station
Chemzyme IV

Super
Pumping Station
Chemzyme IV

Super
Pumping Station
Chemzyme IV

Super
Pumping Station
Chemzyme IV

Description
A minor pumping station that receives regular inflow of fats and greases,
with only a small percentage of its volume composed of other materials.
3 weeks prior to the start of the 3 month trial the wet well was emptied and
cleaned.
Immediately prior to the commencement of the trial the surface of the wet
well was approximately 60% covered in a FOG crust, which was estimated
to be 10 mm thick. ChemSearch personnel applied the product to the wet
well surface using a spray gun.

A minor pumping station that receives a large volume of rags and other
solids debris, as well as some fats and greases in the wastewater flow.
3 weeks prior to the start of the 3 month trial the wet well was emptied and
cleaned.
Immediately prior to the commencement of the trial the surface of the wet
well was approx 50% covered in rags and other debris. Some FOG
deposits were visible on the wet well sides. ChemSearch personnel
applied the product to the wet well surface using a spray gun.
A major pumping station that receives substantial quantities of fat and
greases from the upstream catchment. THa upstream catchment consists
of industrial, commercial and residential areas.
Due to the larges volumes of fats and greases, the wet well is typically
emptied on a weekly basis.
6 days before the start of the 6 week trial the wet well was emptied and
cleaned.
Immediately prior to the commencement of the trial the surface of the wet
well was approximately 95% covered in a FOG crust.
ChemSearch personnel applied the product to the wet well surface using
a spray gun.

This major pumping station had noticed an increase in the levels of fats,
oils and greases received from the upstream catchment.
Prior to the start of the 5 month trial a thick layer of fats and greases was
noted on the wet well surface. This was approximately 0.5-1.0 m thick.
Jetting and a heavy spray programme using the product was carried out to
break up the surface of the crust.

A dry weather pumping station which receives moderate amounts of fat,


grease, rags and other debris.
Prior to the start of the 14 month trial the wet well was emptied and
cleaned.
The product was applied from above ground using a spray gun.
Initial dosing was carried out weekly, this was then reduced to fortnightly
intervals and finally to monthly intervals.

Results
At the end of the trial there was little evidence of any
FOG crust. The product worked well and kept the fats
and grease in watery condition.

It was noted that the fats and greases entering the wet
well actually helped to bind the rags and paper
components together.
The rags and other debris present in the wet well during
the trial severely inhibited the bacterial action of the
product.
The product is not designed to work on the inorganic
debris in the wastewater.
Unfortunately due to the break down of the pumping
machinery the trial had to be terminated early. However,
the results showed that the FOG crust had been
reduced so that it only covered approximately 5% of the
surface of the wet well.

Application of the product softened and reduced the


volume of the fats and grease layer so that the wet well
could be emptied easily.
The trial demonstrated that this product dealt with the
large volumes of fats and grease entering in the
wastewater very well.

The product did not remove the FOG entirely, but did
keep it pliable and the fat was therefore much easier to
remove.
The trial demonstrated that this product dealt with the
large volumes of fats and grease entering in the
wastewater very well.

RETURN TO DATABASE

Company Name: Cleveland Biotech


Trial No
1

Product
Bactaerator (Amnite
L100 + Bacnite)

Location
Pumping Station

Record
The catchment consists of primarily domestic premises with single
commercial discharge (a secondary school).
The FOG forms a shelf at the pump on level and FOG balls also
accumulate in the wet well. The wet well needs cleaning at an interval of
between six weeks to three months.
The product was dosed directly into the pumping station.

Results
A noticeable reduction in the FOG shelf build
up and the amount of FOG balls.

RETURN TO DATABASE
Company Name: COPA
Trial No

Product

Location

Bi-Chem 2000
GL Bio-Sock

WwTW

Bi-Chem 2000
GL Bio-Sock

Sewer

Bio Sock

Pumping Station

Description
The upstream catchment has a population of approximately 500. A
conference centre in the catchment significantly affects the load on
the treatment works as it can cater for around 300 people each day.
The high FOG load in the wastewater causes the formation of a crust
on the primary settlement tank; rising sludge and solids carry over
from the primary settlement tank and blocking of the filter arms.
Prior to the start of the trial, the affected areas of the treatment works
were jetted clean of all FOG accumulation.
The Bio-Sock was suspended in the inlet channel to the primary
settlement tanks.

The sewers at this location are cleaned on an annual basis, typically


during a week at the end of the summer period (holiday season).

A 1 month trial was carried out in the late 1980's at a pumping station
with known FOG problems

Results
The results of using this system are difficult to determine
due to the variable FOG load in the incoming wastewater.
However:
a reduction in fat build up on the primary settlement
tanks was noted.
FOG deposits that remained were softer and easier to
remove,
The fat was broken down into smaller particles that
were able to pass through the filter arms without causing
blockages, and
an improvement in the performance of the treatment
was noted.
Bi-Chem 2000 GL Bio-Sock has been used since August
2004.

The Bio Socks were used here, but they proved to be


expensive, one week's hire of a vactor machine was
cheaper than the product dosing. The product dosing did
not remove all the FOG.
At the end of the trial period it was noted that there had
been a reduction in the amount surface grease scum on
wet well walls, and the numbers of fat blockages in
pumps had been reduced. Therefore the cleaning
frequency of the wet well could be reduced.
Despite good results for this trial, the long-term use of
Bio-Socks was not adopted at this site.

RETURN TO DATABASE
Company Name: Dyno-Rod
Trial No
1

Product
Bioflow

Link to Kent Stainless

Location
Hotel

Record
The hotel had a grease separator, however, the management and staff were
unaware of its existence. Therefore, it had not been maintained for some time.
Manhole inspections and an initial CCTV survey found that grease from the hotel
was solidifying in the sewer as far as 500m downstream. The problem required
immediate attention and the grease separator was pumped out by a drain cleaning
contractor.
A new grease separator was supplied by Kent Stainless, this was installed with the
existing, undersized grease separator being retained for use as a solids trap.
In addition Dyno - Rod installed the "Bioflow" system (an automatic dosing pump
with a drum of "Bioflow" solution) and provided the grease separator maintenance
service. The service contract includes one pump out per year and the grease
separator is inspected every 8 weeks. During the service visits any food debris
present is removed from the separator by hand.
The food basket within the old grease separator was emptied twice per week by a
member of the hotel staff.
Guidance documents were issued to highlight the importance of good kitchen
practices and to reduce the amount of food waste discharged via the sink.

Results
A CCTV survey was carried out at the end of the
trial, this showed the sewer to be in very good
condition.

RETURN TO DATABASE
Company Name: EcoBug Ltd
Trial No
1

Product
Eco-Bug

Location
Pumping Stations

Record
The Eco-Bug product was used at 2 pumping stations and a pipe bridge.
The cast iron bridge blocks with FOG at a location approximately 200m
downstream of a restaurant.
The restaurant has a grease separator installed, however, this was thought
to be situated too close to the kitchens, FOG therefore passes through the
separator and solidifies in the pipe bridge. This causes blockages and
subsequent spills directly to the river.
The Eco-Bug dosing regime involves an annual dose with regular monthly
seeding to maintain the bacterial population.

Results
The local council originally carried out the dosing,
however, operations are now the responsibility of
the local water company.
Information received notes that the regular
monthly dosing has not been carried out for
several months, therefore the problems at this
site are likely to return.

RETURN TO DATABASE
Company Name: Environmental Biotech UK
Trial No

Product

Location

GES System

Pumping Station

GES System

Sewer

GES System

Pumping Station
& Sewer

GES System

Town Centre

Description
The pumping station serves a petrol station, burger restaurant
and 20 residential properties.
The pumping station had a history of heavy fat build up which
required a high number of reactive site visits to rectify operational
problems.
Prior to star of a 6 month trial a thick crust of FOG covered the
surface of the wet well.

A 450mm sewer suffered from recurring FOG related blockages,


which lead to flooding of a nearby car park. Access to site for
sewer jetting machines is difficult.
Historically there was a problem with FOG build up at the
pumping station and in the sewer leading to the pumping station.
A factory producing food products discharges into the sewer,
which is believed to be the cause of the problem. The factory has
an on site treatment works which treats the discharge from the
factory prior to discharge to the public sewer.
The product was installed to dose into the sewer and at the
pumping station. It was applied using a spray gun. Dosing
continued for the duration of the 6 month trial.

Over the past ten years this road has had many FOG related
issues. These are largely thought to be due to the high
concentration of food catering outlets. There have been odour
complaints, sewer blockages, sewer flooding incidents, many
reports of rats and the loss of the use of toilets.
Environmental Biotech GES system was installed in the kitchens
of 8 food catering premises for a year long trial.
It should be noted that other FOG management systems/devices
were installed at a number of the other premises in the road.
Guidance documents were issued to highlight the importance of
good kitchen practices and to reduce the amount of food waste
discharged via the sink.

Results
After 1 month of dosing the crust turned a foam consistency.
After 2 months of dosing no FOG was obvious on the chamber
walls and the remaining fat in the wet well had formed small balls.
After 3 months of dosing very little fat was evident and the
chamber walls and pump bodies were free of FOG accumulation.
The GES system has now been in place for approximately 3
years and continues to operate effectively to prevent the build up
of FOG.

No results were available

The sewer was still blocked with FOG at the end of the trial.
The FOG at the pumping station changed during the trial period
from a lumpy texture to a soft mousse, however, this still caused
problems at the pumping station. Environmental Biotech
suggested that the design of the pumping station and that fact
that fat built up on the rags present in the pumping station, had
meant that the FOG had not been completely removed.

During the trial period it was noted that there were no odour
issues and there was a significant reduction in the numbers of
rats at this Town Centre location. There were also no reported
sewer blockages or flooding incidents in the local drain/sewer
system. This trial significantly reduced the amount of FOG being
discharged to the local drain/sewer system.

RETURN TO DATABASE
Company Name: Environmental Innovations
Trial No

Product

Location

Fatstrippa

Commercial
Kitchen

Fatstrippa
(FS10)

Commercial
Kitchen

Fatstrippa

Commercial
Kitchen

Record
The appropriate Fatstrippa interceptor size was selected and
installed. Staff training was carried out upon installation and was
re-enforced several weeks later during a follow up courtesy call.
Some problems were experienced with maintenance of the units
during the trial period.

The separator was installed in the kitchen for the trial.


There was not any grease management in kitchen. The
proprietor was explained that a discharge licence was required
for all FSEs and the Fatstrippa interceptor was installed and staff
training was carried.

Results
The maintenance record sheet improves traceability of the
waste but is open to abuse.
The waste removed by the unit is in a much more
concentrated form than when removed by hand from a
traditional passive separator, therefore it is cheaper to
dispose of.
The premise owner was very happy with the system as it
was easy to clean and did not take up much space.
The staff training was carried out second time because the
supplier was not satisfied with the maintenance being
carried out at this site.

RETURN TO DATABASE
Company Name: Environmental Products and Services Ltd.
Trial No
1

Product
GreaseShield
Mechanical Interceptor

Location
Commercial Kitchens

Description
Environmental Prod and Serv Ltd supplied a package which
included the entire sink unit with a flood interceptor unit
followed by the interceptor itself. This was installed inside
the kitchen, initially incorrectly by the plumber and problems
were experienced with the filter basket unit. The was later
repaired.

Results
Sampling of the effluent from the unit was carried out
but results were very poor - due to initial incorrect
installation. The final sample yielded a much more
encouraging result but was still above the limit
prescribed by the local authority (50mg/l of FOG).

RETURN TO DATABASE
Company Name: FM Environmental Ltd
Trial No
1

Product
Grease
Guardian

Location
Commercial
Kitchen

Description
A large supermarket with a hot food delicatessen, bakery and butcher
had 4 existing Grease Guardian units. Although these units were
installed, blockages were still occurring in the downstream sewer
approximately once per year. Blockage crews noted significant volumes
of FOG in the sewer on each occasion.
Maintenance practices of the Grease Guardian units were subsequently
examined. It was found that the supermarket staff were carrying out daily
maintenance on the units, however, they were unsure how the waste
should be disposed of and so it was tipped down a surface water gully at
the side of the building.
The manufacturers of the Grease Guardian units noted that these
systems are approximately 10 years old and records show they were
long overdue a service. The manufacturers examined the units and a
report shows that 3 of the 4 units were in good working order, the fourth
unit had a broken heating element, which was subsequently replaced.
Further investigations indicated that a sink, adjacent to the fourth unit,
was not plumbed into the unit. It was suggested that this may
have been the cause of the FOG build up downstream.
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged
via the sink.

Results
Following the investigations at this location it was
recommended that:
the additional sink should be connected to the fourth
Grease Guardian unit.
a waste oil collector should be contracted to remove the
waste from the units.

RETURN TO DATABASE
Company Name: JFC Manufacturing Co. Ltd
Trial No
1

Product
GT02

Location
Commercial Kitchen

GT02

Commercial Kitchen

Description
This location was a small but busy takeaway. Investigations at this site
showed that there was an adequately sized external grease separator
already installed. It was located in a suitable position and was cleaned
by hand twice per week by an in-house employee; this included the
use of a degreaser.
The owner stated that the waste from the units was collected by a
used cooking oil collection company, however, details could not be
provided.
The investigations highlighted that a washing machine was plumbed
into the grease separator. The detergents and hot water from the
washing machine would be quite detrimental to the performance of the
separator
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged
via the sink.

This site is a convenience shop with a hot food delicatessen.


Investigations at this site found that a grease separator installed
underground in the back yard of the premises. This unit was a
domestic JFC model, which was greatly undersized for the amount of
FOG being discharged.
An initial CCTV survey showed a significant build up of FOG on the
walls of the pipework downstream of the separator. There was also
some structural damage to the pipework which may have exacerbated
the problem. The site experienced blockages on two or three
occasions over the past 6/7 years.
A new grease separator, JFC 200 litre GT02 model, was subsequently
installed downstream of the existing grease separator.
Once the new grease separator was installed, the pipework was
thoroughly cleaned by a jetting crew and another CCTV survey was
carried out.
Following advice from the manufacturer maintenance of the unit was
conducted at an interval of 2 weeks.
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged
via the sink.

Results
The unit appeared to performing adequately and no
odour problems were experienced during the trial
period.
It was recommended that the use of the degreaser
to "clean" inside the unit was stopped. Use of small
amounts of degreaser to clean around the unit once
closed could continue.
It was recommended that the washing machine was
disconnected from the grease separator.

Although it was intended to maintain the separator


as per manufacturer's recommendations, this
proved difficult for various reasons. On several
occasions, when the project technician arrived at
the site to clean the separator, deliveries were
being made and in this case cleaning had to be
postponed. However, it is likely to be the case in
reality and showed the sensitivity of the system to
perform outside of the normal maintenance interval.

RETURN TO DATABASE
Company Name: Kent Stainless
Trial No
1

Product

Location

3270 l Kent Stainless Hotel


Interceptor

Link to Dyno-Rod

Record
The hotel had a grease separator, however, the management and staff
were unaware of its existence. Therefore, it had not been maintained
for some time.
Manhole inspections and an initial CCTV survey found that grease from
the hotel was solidifying in the sewer as far as 500m downstream. The
problem required immediate attention and the grease separator was
pumped out by a drain cleaning contractor.
A new grease separator was supplied by Kent Stainless, this was
installed with the existing, undersized grease separator being retained
for use as a solids trap.
In addition Dyno - Rod installed the "Bioflow" system (an automatic
dosing pump with a drum of "Bioflow" solution) and provided the grease
separator maintenance service. The service contract includes one
pump out per year and the grease separator is inspected every 8
weeks. During the service visits any food debris present is removed
from the separator by hand.
The food basket within the old grease separator was emptied twice per
week by a member of the hotel staff.
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged
via the sink.

Results
A CCTV survey was carried out at the end of the
trial, this showed the sewer to be in very good
condition.

RETURN TO DATABASE
Company Name: Metro Rod
Trial No
1

Product
Fatbuster

Location
Town centre
catchment

Description
Historic problems of FOG accumulation in a town centre
catchment.
The public sewer was cleaned prior to the start of the trial.
"Fatbuster" units were installed in "high-risk" food outlets within
the catchment in order to prevent the build up of the FOG in the
public sewer.
The "Fatbuster" unit automatically doses fat-digesting microorganisms into the drainage system.

Results
Results showed that 8 months after installation of the units
FOG had begun to accumulate in the public sewer. However,
some of the restaurants had noticed a reduction in fat and
grease blockages within their private systems since the
installation of the units.
The units were not successful in terms of preventing FOG build
up in the public sewer. However, the following factors should
be considered:
existing poor hydraulic conditions,
not all the restaurants in the catchment were fitted with the
units, and
low rainfall during the trial period.

RETURN TO DATABASE
Company Name: Miskin Interceptors
Trial No

Product

Location

Miskin
Commercial
Interceptors Kitchen

Miskin
Town Centre
Interceptors Commercial
Kitchens

Miskin
Commercial
Interceptors kitchen

Description
The site sell fresh fish and also cooks fish products such as fish pies etc.
When first approached to take part in the trial, the proprietor was surprised
that they had been described as a FOG hotspot and could not recall ever
having considerable problems with their drains.
Despite an initial CCTV survey showed a build up of FOG in the drain. In a
later CCTV survey, structural problems were discovered in the clay pipe
downstream of the shop which may have contributed to the build up of
FOG.
Investigations found that it would be difficult to install a single unit due to
the lacke of external space and the arrangement of the pipework. Suitable
locations were found for three separate Miskin Interceptor units.
The first unit catered for a sink used to rinse fish in the front of the shop.
The second served a large double sink in the kitchen used for pot wash
etc., and
The third catered solely for a combination oven used to cook fish.

The Town Centre has a history of FOG problems (sewer blockages and
associated sewer flooding), partly due to the high concentration of
restaurants in the town centre.
17 Miskin grease separators were been installed in the kitchens of 16
commercial catering premises for a 6 month trial. The grease separators
were installed to take the wastewater from sinks in the premises.
The units were removed and emptied by Miskin on a fortnightly basis.
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged via
the sink.

The food catering outlet selected was alleged to be the cause of known
problems of repeat blockages and internal flooding incidents from a
manhole in the kitchen extension of a property, both thought to be caused
by the accumulation of FOG in the local sewer system.
The location is well known to the local Environmental Health Officer (EHO)
who attributes the previous incidents to FOG being discharged from a
neighbouring Chinese takeaway, as this is the only likely significant source
of FOG discharging to the affected section of sewer.
A 6 month trial used two Miskin Interceptor units installed at the kitchen,
one internally and one externally.
Guidance documents were issued to highlight the importance of good
kitchen practices and to reduce the amount of food waste discharged via
the sink.

Results
In the latter stages of the trials three flooding incidents occurred
at the trial site. In each case a blockage had occurred
downstream of the premise.
On the first occasion the jetting crew noted blue paper hand
towel in the sewer along with a slight FOG built up on the walls
of the manhole. The use of blue paper hand towel was
subsequently stopped.
A second incident occurred within two weeks of the first
incident. On this occasion it was presumed that the FOG in the
pipework was the cause of the blockage. However, a follow up
CCTV survey discovered serious structural damage to the clay
pipework downstream. It is likely that this caused a flow
restriction.
The third blockage occurred just downstream of the separator
allocated to the combination oven. It is possible that some small
particles will pass through the grease separator, which may
have been sufficient to block the small pipe downstream of the
separator.

The grease separators worked well and the trial demonstrated


to the premise owners how these grease separators work and
how much fat, oil and grease they actually capture, just from the
waste going down the kitchen sinks.

The trial was deemed to be successful as no blockages or


flooding events occurred during the six month trial period.
CCTV evidence confirmed that over the trial period little to no
build up of FOG or debris had occurred in the local drain/sewer.

RETURN TO DATABASE
Company Name: NRP
Trial No

Product

Location

NRP P100 SD
Sewer
Dispenser & Bio-Kat

Bio-Kat

Sewer

Bio-Kat

Pumping
Station

Record
The sewer has a history of blockages and required cleaning every 2-4
weeks in order to remove the FOG build up.
A trader at the top of the sewer manufactures Indian sweets.
A NRP P100 SD Dispenser was installed in a manhole and which
dosed the Bio-Kat product for a 30 day trial period in 2004.
Nutriox dosing was being carried out to solve odour problems at 2
pumping stations at this location. A length of sewer running across a
golf course kept blocking due to FOG and the wastewater treatment
works had mousse on the ditches.
It was therefore decided to replace the Nutriox dosing with the NRP
product (Bio-Kat) to remove both the odour and the build up of FOG.
The dosing was carried out upstream of the location of the odour
complaints. The product was applied by drip-feeding directly into the
sewer from a manhole. This trial ran for a period of 30 days during the
winter of 2004.

The dosing was required because a factory upstream was exceeding


their BOD/COD consent. The factory manufactures ready meals.

Results
It was difficult to determine the complete level of success of
the trial due to third party intervention, where the sewer
became blocked with plastic bags. NRP Ltd noted in their
report that the product did reduce the level of FOG build-up

It was difficult to assess the impact of the product on the


odour problem due to the time of year the trial was carried
out.
The local water company were keen to carry out a similar
trial but during warmer weather when the odour problems
would be worst.
There appeared to be little impact on the mousse at the
wastewater treatment works, NRP suggested that this was
because the concentration of the product used during this
trial was sufficient for odour removal, but not high enough to
have an effect on the problems at the treatment works.

The trial was carried out in 2005, and upon completion the
factory achieved their BOD/COD consent limit. The
reduction in the amount of FOG build up by 94% was an
additional effect of dosing.

RETURN TO DATABASE
Company Name: Organica
Trial No

Product

Location

Formula 33

WWTW

Formula 33

WWTW

Description
Trial at WWTW with FOG problems causing blockages in
sludge pipelines

Trial at WWTW, biological dosing was carried out at this site


for a period of 4-6 months.

Results
Enzyme dosing had some benefits but was not totally effective
at stopping fat congealing in the sludge pipelines.
Contradictory information about this trial was supplied.
Information stated that:
the dosing resulted in an increase in filamentous bacteria
which caused bulking in the activated sludge and sludge.
Also,
once dosing of the product had stopped there was an
increase in filamentous bacteria, which caused bulking in the
activated sludge and sludge.
It is difficult to determine from this information the effect of the
product.

It was noted that the product kept incoming solids mobile and
prevented FOG accumulation on weirs and channels.
However, it was not used long enough to see long term
benefits.

RETURN TO DATABASE
Company Name: QM Environmental Services Ltd. (Formerly: QM Bioscience)
Trial No
1

Product
Microcat

Location
Trunk sewers

rvices Ltd. (Formerly: QM Bioscience)


Description
A long term trial carried out over 3.5 years.
The sewers were cleaned prior to the start of the trial period.
The aim, of the dosing was to prevent the accumulation of
FOG in these large sewers.
The product comes in the 0.5g bags of powder, which are
placed in the sewer from the manholes on a monthly basis.
The product is gradually released from the bag, and the bags
themselves gradually degrade in the sewer.

Results
Although fat did build up in the sewers it was noted to be of
a softer consistency, making it easier to remove and control.

RETURN TO DATABASE
Company Name: PVC Fabrications (Sales) Ltd.
Trial No
1

Product
21 litre PVC
Fabrications Passive
Interceptors

Location
Commercial Kitchen

Description
The butcher shop discharges to a sewer which has had
several blockages in recent years and had used a drain
cleaning contractor to jet the sewer.
An initial CCTV survey was carried out and a notable build
up of FOG was found in the pipework.
During investigations at this site it was discovered that the
sinks were plumbed into the soakaway rather than foul
drain. This problem was subsequently rectified by the
landlord of the building.
Two grease separators, one to cater for each set of sinks,
were installed. Once the traps were installed, the butcher
shop staff undertook the maintenance on a weekly basis.
The waste that was removed from the traps was placed in
their regular refuse bins for collection.

Results
Little was known of the effluent from a butchers shops
prior to this trial and it is now clear that a greater FOG
loading is generated than was expected.

RETURN TO DATABASE
Company Name: Rodney Perrigo Ltd
Trial No
1

Product
Auto Well Washer

Location
Pumping Station

Description
There are historic FOG problems at this pumping station.
The wet well washer was installed for a one year trial.

Results
The information regarding this trial did
not include any results/findings.

RETURN TO DATABASE
Company Name: Swan Enviro
Trial No
1

Product
Grease separator

Location
Town Centre

Record
Over the past ten years this road has had many FOG related
issues. These are largely thought to be due to the high
concentration of food catering outlets. There have been odour
complaints, sewer blockages, sewer flooding incidents, many
reports of rats and the loss of the use of toilets.
Swan Enviro Grease separator was installed externally at a food
catering premise for a year long trial.
It should be noted that other FOG management systems/devices
were installed at a number of the other premises in the road.
Guidance documents were issued to highlight the importance of
good kitchen practices and to reduce the amount of food waste
discharged via the sink.

Results
The grease separator significantly reduced the amount of
FOG entering the drain/sewer system. It was noted that
the performance could be improved with the addition of
the Swan Enviro dosing product "Swan Freshflo Dosing
Fluid". This would also make maintenance practices less
unpleasant.
During the trial period it was noted that there were no
odour issues and there was a significant reduction in the
numbers of rats at this Town Centre location. There were
also no reported sewer blockages or flooding incidents in
the local drain/sewer system. This trial significantly
reduced the amount of FOG being discharged to the local
drain/sewer system.

RETURN TO DATABASE
Company Name: Watling-hope
Trial No
1

Product
BioCake

Location

Record

Pumping Station The pumping station has FOG problems, and receives
the discharge from a relatively small catchment of
about 20-25 domestic properties and one pub.
Three FOG treatment devices, 2 Big Dippers (one
connected to a pre-wash sink the second attached to
a double sink) and a Grease Guzzler were installed at
the pub but the problems at the pumping station
remained. Therefore the BioCake product was
installed at the pumping station as an additional FOG
control measure. Three BioCakes were suspended in
the wet well for a trial period of 3 months.

Results
At the end of the trial the FOG built up to a similar level to that at the
beginning of the trial (before cleaning), so the BioCake had made
little, if any difference. The FOG had accumulated around the side
walls, around the pumps, and on the netting holding the BioCakes.
The cake at the lowest level had dissolved completely, the other had
partially dissolved and the cake at the highest level, which didn't
appear to be under the water-level very much, was almost whole.
The reason that the product didnt work as well as anticipated is
possibly due to a lack of movement around the wet well as there
isn't much inflow in that pumping station and the water level in the
wet well doesn't rise/fall quickly. The cakes may not have been
installed at the correct levels as one had not dissolved at all.