Beruflich Dokumente
Kultur Dokumente
(CDR)
CDR Number:
For Mechanical, Corrosion and
Erosion damage anomalies.
GP III
07-093
Pipework
Section 1 :
Installation :-
Details of System
Date Reported :-
N/A
9/23/2007
Design parameters
MC Work Order. :-
Yes
GP3008-PR-PI-0006
Component History
Pressure (bar.g)
Temperature C
Flow (m/s)
3"-PG-08076-D15A
Details of Anomaly
Drawing No.
Material Type :-
22Cr Duplex
Component OD:-
3" (75)
Type
Location
Anomaly Type:-
Vibration
Equipment Type:-
Anomaly Location:-
External
Component:-
Leak:-
No
Anomaly Mechanism:-
Deferment:-
No
Pitting Depth :-
N/A
N/A
Anomaly Found:
N/A
Oil = m3
Value =
Extent:-
Gas = scfd
Value =
WI = m3
Value =
Solids present:-
Pipework
Instrument Connection
Area:-
N/A
Routine Inspection
N/A
Fabric Maintenance
Coating system:-
Substrate:-
Heat Traced:-
Break down %
Substate Condition:-
Insulation Class:-
Anodes Fitted:-
Insulation Defect:-
Section 2: Additional information not covered in Section 1 above. (Note - use Sheet 2 for sketch / photo of defect location).
Both tube sections of the flow transmitter FT-08-5500 have low stiffness and natural frequency and are vibrating significantly. Recommend that
hancuff supports from flange to instrument DBB valves be fitted. See original JMD VRA report GP3/07/117 on page 2 for details.
Print name
J. McGhee
Job Title:
JMD Specialist
Date
27/09/2007
ACTION PRIORITY:
Print name
Date
ACTION
Print name
C. Beedie
Signature
Date
Signature
Date
Signature
Date
Signature
Date
Print name
Job Title
Date
No
Continuation Sheet
2 of 2
Continuation sheet for further text, sketches etc. If not in electronic format, forward separately through internal mail system.
CDR Number:
GP III
07-093
Pipe Details
3"-PG-08076-D15A
WO Number
CDR Number
Location
Line Number
Material / Grade
P&ID Number
Wall Thickness
Medium
Temperature Rating
Pipe Coating
Pressure Rating
N/A
07-093
HP Gas Comp Skid
3"-PG-08076-D15A
22Cr Duplex
Design/S
Current
Operatin 0
0
Operatin 0
Desig
Comment
Desig
Comment
Attach drawings of pipe system, inspection reports, etc where available. Indicate any access restrictions a
proximity to other equipment.
Repair Specification
ICP approved
Nature of Defect
Current Size
Cause
Effect
Yes/No
Other (specify in Page 2)
Area
Corrosion Yes/No
External Yes/No
Perforate Yes/No
d
Depth
Erosion
Internal
Yes/No
Yes/No
Maximu
m
Maximu
Minimum
Minimum
Other Information
Note: This should include any remarks on previous repairs, fire protection requirements, etc
Integrity Review
Date Fitted
Inspection
Frequency
Inspection Method
Last
inspection
Date
Current WT
Life of repair
ea
Yes/No
Yes/No
mentation of Repair
requirements, etc