Sie sind auf Seite 1von 6

Profis Anchor 2.5.

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

1
6/14/2015

Specifier's comments:

1 Input data
Anchor type and diameter:

HIT-HY 200-R + HIT-Z M12

Effective embedment depth:

hef,opti = 60 mm (hef,limit = 80 mm)

Material:

DIN EN ISO 4042

Evaluation Service Report:

ETA 12/0028

Issued I Valid:

3/15/2013 | 2/10/2017

Proof:

Design method ETAG BOND (EOTA TR 029)

Stand-off installation:

eb = 0 mm (no stand-off); t = 25 mm

Anchor plate:

lx x ly x t = 600 mm x 300 mm x 25 mm; (Recommended plate thickness: not calculated)

Profile:

no profile

Base material:

uncracked concrete, C40/50, fcc = 50.00 N/mm2; h = 250 mm, Temp. short/long: 30/40 C

Installation:

hammer drilled hole, Installation condition: Dry

Reinforcement:

no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
with longitudinal edge reinforcement d >= 12

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

2
6/14/2015
y

2 Load case/Resulting anchor forces


Load case: Design loads
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Tension force
Shear force
Shear force x
Anchor
1
7.957
1.667
1.667
2
7.957
1.667
1.667
3
4.242
1.667
1.667
4
4.242
1.667
1.667
5
0.527
1.667
1.667
6
0.527
1.667
1.667
max. concrete compressive strain:
0.08 []
max. concrete compressive stress:
2.37 [N/mm2]
resulting tension force in (x/y)=(-117/0):
25.452 [kN]
resulting compression force in (x/y)=(276/0): 25.452 [kN]

Shear force y
0.000
0.000
0.000
0.000
0.000
0.000

x
Compression

Tension
2

3 Tension load (EOTA TR 029, Section 5.2.2)


Load [kN]
7.957

Capacity [kN]
36.667

Utilization bN [%]
22

Status
OK

Combined pullout-concrete cone failure**

25.452

84.171

31

OK

Concrete Breakout Strength**

25.452

56.142

46

OK

N/A

N/A

N/A

N/A

Steel Strength*

Splitting failure**
* anchor having the highest loading

**anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN]
55.000

gM,s
1.500

NRd,s [kN]
36.667

NSd [kN]
7.957

3.2 Combined pullout-concrete cone failure


Ap,N [mm2]
178200

A0p,N [mm2]
32400

2
tRk,ucr,25 [N/mm ]
22.00

scr,Np [mm]
180

ccr,Np [mm]
90

yc
1.000

2
tRk,ucr [N/mm ]
22.00

k
3.200

yg,Np
1.000

yg,Np
1.000

ec1,N [mm]
117

yec1,Np
0.461

ec2,N [mm]
0

yec2,Np
1.000

ys,Np
1.000

N0Rk,p [kN]
49.763

NRk,p [kN]
126.256

gM,p
1.500

NRd,p [kN]
84.171

NSd [kN]
25.452

cmin [mm]
800

hef,Helix [mm]
60

yre,Np
1.000

3.3 Concrete Breakout Strength


Ac,N [mm2]
178200

A0c,N [mm2]
32400

ccr,N [mm]
90

scr,N [mm]
180

ec1,N [mm]
117

yec1,N
0.461

ec2,N [mm]
0

yec2,N
1.000

N0Rk,c [kN]
33.192

gM,c
1.500

NRd,c [kN]
56.142

NSd [kN]
25.452

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

ys,N
1.000

yre,N
1.000

k1
10.100

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

3
6/14/2015

4 Shear load (EOTA TR 029, Section 5.2.3)


Load [kN]
1.667

Steel Strength (without lever arm)*


Steel failure (with lever arm)*

Capacity [kN]
21.600

Utilization bV [%]
8

Status
OK

N/A

N/A

N/A

N/A

Pryout Strength**

10.000

243.408

OK

Concrete edge failure in direction x+**

10.000

131.759

OK

* anchor having the highest loading

**anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN]
27.000

VRd,s [kN]
21.600

gM,s
1.250

VSd [kN]
1.667

4.2 Pryout Strength (Concrete Breakout Strength controls)


Ac,N [mm2]
178200

A0c,N [mm2]
32400

ccr,N [mm]
90

scr,N [mm]
180

k-factor
2.000

k1
10.100

ec1,V [mm]
0

yec1,N
1.000

ec2,V [mm]
0

yec2,N
1.000

ys,N
1.000

yre,N
1.000

N0Rk,c [kN]
33.192

gM,c,p
1.500

VRd,c1 [kN]
243.408

VSd [kN]
10.000

a
0.027

b
0.043

yec,V
1.000

4.3 Concrete edge failure in direction x+


hef [mm]
60

dnom [mm]
12.0

k1
2.400

c1 [mm]
800

Ac,V [mm2]
568750

A0c,V [mm2]
2880000

ys,V
0.931

yh,V
2.191

ya,V
1.000

ec,V [mm]
0

V0Rk,c [kN]
490.518

gM,c
1.500

VRd,c [kN]
131.759

VSd [kN]
10.000

yre,V
1.000

5 Combined tension and shear loads (EOTA TR 029, Section 5.2.4)


bN
0.453
a

bV
0.077

a
1.500

Utilization bN,V [%]


33

Status
OK

bN + bV 1

6 Displacements (highest loaded anchor)


Short term loading:
NSk

0.390 [kN]

dN

0.007 [mm]

VSk

3.704 [kN]

dV

0.185 [mm]

dNV

0.185 [mm]

dN

0.019 [mm]

dV

0.296 [mm]

dNV

0.297 [mm]

Long term loading:


NSk

0.390 [kN]

VSk

3.704 [kN]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

4
6/14/2015

7 Warnings
Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading!

Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with EOTA TR 029, Section 7!
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of EOTA TR029! For larger
diameters of the clearance hole see Chapter 1.1. of EOTA TR029!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Characteristic bond resistances depend on short- and long-term temperatures.
Edge reinforcement is not required to avoid splitting failure

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

6/14/2015

8 Installation data
Anchor plate, steel: Profile: no profile; 0 x 0 x 0 mm
Hole diameter in the fixture: df = 14 mm
Plate thickness (input): 25 mm
Recommended plate thickness: not calculated
Cleaning: No cleaning of the drilled hole is required

Anchor type and diameter: HIT-HY 200-R + HIT-Z M12


Installation torque: 0.040 kNm
Hole diameter in the base material: 14 mm
Hole depth in the base material: 90 mm
Minimum thickness of the base material: 120 mm

8.1 Recommended accessories


Drilling
Suitable Rotary Hammer
Properly sized drill bit

Cleaning
No accessory required

Setting
Dispenser including cassette and mixer
Torque wrench

300

6
75

150

150

150

75

300

100

200

200

100

Coordinates Anchor [mm]


Anchor
1
2
3

x
-200
-200
0

y
75
-75
75

c-x
9800
9800
10000

c+x
1200
1200
1000

c-y
1075
925
1075

c+y
9925
10075
9925

Anchor
4
5
6

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

x
0
200
200

y
-75
75
-75

c-x
10000
10200
10200

c+x
1000
800
800

c-y
925
1075
925

c+y
10075
9925
10075

Profis Anchor 2.5.0

www.hilti-me.com
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:

Page:
Project:
Sub-Project I Pos. No.:
Date:

6
6/14/2015

9 Remarks; Your Cooperation Duties


Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan