The BP-S (single plate) and the BP-D (dual plate) are single piece, powder-coated steel backplates
designed to accommodate the MP/MPX enclosures, a Magnum inverter, and the inverter hood (two of
each component for the BP-D); thus making the complete system appear seamless. These backplates
also provide a non-combustible surface for mounting the inverter(s) on a wall. Designed with PEM (i.e.,
internally threaded) nuts, each backplate is shipped with the necessary hardware for mounting the
components listed above.

Mounting the Backplates to the Wall


Mount all the backplates to the wall using appropriate hardware (not supplied). The mounting holes on
the backplates are spaced to accommodate wall studs that are placed 16 on center (refer to Figures
1 and 2). If the mounting holes dont fall on wall studs, attach a sheet of plywood (minimum ) or
APA-rated sheathing on the wall. The backplates with the attached components are heavy, so ensure
that all the backplates are securely mounted.
Info: If mounting more than one backplate, start with the right-most backplate and work
to the left.
Info: Each backplate has pre-drilled side holes (see Figures 1 and 2, Detail C) which can be
used to connect all the backplates together prior to mounting them on the wall.
Info: For a cleaner look, the four attachment clips on the far right backplate can be removed
(snapped off) prior to mounting (see Figures 1 and 2, Detail B)
CAUTION: If you remove the attachment clips, you lose the 16 on center measurement
on both the BP-S and BP-D backplates (right side of BP-D only).

Mounting Components on the Backplates


The dual backplate is designed to support two MP enclosures, two Magnum inverters, and two inverter
hoods. You also have the option to mount just one MP enclosure, a MPX extension, and two connected
inverters. Once the backplates are mounted, follow the steps below to attach (in this order) the enclosures (MP or MPX), the Magnum inverters, and then the inverter hoods. Refer to Figures 1 thru 4.

A - Enclosures (MP or MPX extension)


1. Screw four Hex head bolts halfway into the backplate where the enclosure will be mounted
(M or X holes).
2. Hang the MP/MPX enclosure on those four Hex head bolts using the enclosures keyhole slots.
3. Tighten the Hex head bolts to secure the enclosure to the backplate.
4. Repeat steps 1-3 to mount any additional MP enclosures or MPX extensions (M2 or X2 holes).

B - Magnum Inverters
1. Place the Magnum inverter on top of the enclosure.
2. Secure the inverter to the backplate using four Hex head bolts and the inverters keyhole slots
(I holes).
3. Tighten the Hex head bolts to secure the inverter to the backplate.
4. Repeat steps 1-3 to mount any additional Magnum inverters (I2 holes).

C - MP Hoods
1. Screw two Hex head bolts halfway into the backplate where the inverter hood will be mounted
(H holes).
2. Place the inverter hood on these screws and tighten securely. Ensure that the bottom edge of the
hood is flush against the top of the Magnum inverter.
3. Repeat steps 1 and 2 to mount any additional inverter hoods (H2 holes).

PN: 64-0048 Rev A

BP-S and BP-D Instruction Sheet


16 15/ 16
16

3/4

3 1/ 2
TO P

5/16

T h e in v e r t e r a n d p a n e ls w ill o n ly
in s t a ll c o r r e c t ly w h e n t h is p la t e is
in s t a lle d w it h t h e t o p f a c in g u p.
6 2 -0 0 2 9Re v A

5/ 16

Mounting Holes
H = Hood
I = Inverter
X = MPX
M = MP enclosure

X/ M

X/ M

39 1/ 4

M
16

SIDE VIEW

16

3 /4

Notes:
1. All dimensions are in inches.
2. Shipping Dimensions:
18 3/16 x 1 1/16 x 41 9/16.
3. Material = 16-gauge steel.
4. Finish = Powder-coated
white.
5. Weight: 15.5 lbs. (7.1 kg),
Shipping Wt: 17.5 (8.0 kg).
6. Includes ten 1/4-20 x 3/4
Hex bolts; for mounting the MP
enclosure, a Magnum inverter,
and the inverter hood.

1 5 /1 6

TOP VIEW
5/ 16

5/16

1
5/ 16

5/16
15/16

Mounting Holes (x10)


DETAIL A

5/ 16

15/16

Attachment Clips (x4)


DETAIL B

Side Holes (x6)


DETAIL C

Figure 1, BP-S Backplate Dimensions


2

2010 Magnum Energy, Inc.

BP-S and BP-D Instruction Sheet


32 15/ 16
16
3 1/ 2

3/ 4

16

H2

H2

H1

H1

TO P

T h e in v e r t e r a n d p a n e ls w ill o n ly
in s t a ll c o r r e c t ly w h e n t h is p la t e is
in s t a lle d w it h t h e t o p f a c in g u p.

5/16

6 2 -0 0 2 9Re v A

Mounting Holes
H1 = Hood#1
H2 = Hood#2
I1 = Inverter#1
I2 = Inverter#2
X1 = MPX#1
X2 = MPX#2
M1 = MP enclosure#1
M2 = MP enclosure#2

I2

I2

I1

I1

I2

I2

I1

I1

X2 /M 2

X2 /M2 X1 /M 1

X1 /M1

39 1/ 4

X2

X2 X1

X1

5/ 16

M2

M2 M1

M1
SIDE VIEW

32

1 5 /1 6

32

3 /4

TOP VIEW
5/16

Notes:
1. All dimensions are in inches.
2. Shipping Dimensions: 34 3/16 x 1
1/16 x 41 9/16.
3. Material = 16-gauge steel.
4. Finish = Powder-coated white.
5. Weight: 29.5 lbs. (13.4 kg), Shipping Wt: 33.5 lbs (15.2 kg).
6. Includes twenty 1/4-20 x 3/4 Hex
bolts; for mounting two MP enclosures, two Magnum inverters, and
two inverter hoods.

5/ 16

11
5/ 16

/4

5/16
15/16

5/ 16

Mounting Holes (x20)


DETAIL A

Side Holes (x6)


DETAIL C
15/ 16

Attachment Clips (x4)


DETAIL B

Figure 2, BP-D Backplate Dimensions


2010 Magnum Energy, Inc.

BP-S and BP-D Instruction Sheet


Hood

Hood

Inverter
Inverter

MP Enclosure

MP
Enclosure

Angled View

Front View

Figure 3, Installing Components on a BP-S Backplate

Hood #2

Inverter #2

Hood #1

Inverter #1

Hood #2

Hood #1

Inverter
#2

Inverter
#1

MPX
MP
Enclosure

MP Enclosure

MPX

Angled View

Front View

NOTE: Magnum recommends that the MPX be mounted on the left side of the BP-D backplate.

Figure 4, Installing Components on a BP-D Backplate