PlusConfig

Check features
CHECK ADDRESS
1

All you have to do is to select an address and then click on the symbol to
-

1:

PING Request the status of that address.


You find the reply of the PING command at the bottom of your screen:

If you dont receive a reply, the address icon changes to:

2:

SET Activate the address ( 1 ) ON

3:

TOGGLE Switch the address ON-OFF-ON-

4:

CLEAR Deactivate the address ( 0 ) OFF

5:
-

FIND PORTS To find the module(s) in which the selected address is used.
When you click on this icon the search result window appears:

Resize window
Go to selected module

Minelec

Go to port of
selected module

Close window

Resize window
1
Minelec N.V., Isidoor Van Beverenstraat 59, 1702 Groot-Bijgaarden, Belgium
Tel : +322 460 31 75, Fax : +322 461 00 24, www.luxom.be

Test features

CHECK MODULE
6

7
8

6:
PING FOR OPEN STRAP/BUTTON To trace the MIN number of a module.
Push the MIN button on the module briefly (the MIN led starts blinking) and click to trace the MIN
number:

Note: This data is only shown


when the module is present in
the project database.

This window contains all the detailed information about the module.
In treeview, if the module is present in your project, a lightning flash is displayed over the module:
Note: The MIN led stops blinking automatically after 3 minutes, OR when you push again briefly on the
MIN button OR when you push the MIN button of another module.
7: PING MODULE(s) To check if the module is present on the network.
You can check the presence of a single module or a complete group of modules.
The term group (location) means all modules that may be present in a:
Project, Building, Floor, Area or Electrical Cabinet.
In the treeview, select the module or location which you wish to check, click on the right mouse button
and select PING Module(s).
Minelec

2
Minelec N.V., Isidoor Van Beverenstraat 59, 1702 Groot-Bijgaarden, Belgium
Tel : +322 460 31 75, Fax : +322 461 00 24, www.luxom.be

Test features

If the module is present on the network, the next window appears:

If the module is not present on the network, the module icon changes from

to

8: CHECK MODULE(s) If you want to compare the content of the module with the project database.
In the treeview, select the module or location you wish to check, click on right mouse button and select
Check Module(s).
Check window:

Check result window:

If the data in the module is different


from the data in the project database,
the module icon changes from
to
Minelec

.
3

Minelec N.V., Isidoor Van Beverenstraat 59, 1702 Groot-Bijgaarden, Belgium


Tel : +322 460 31 75, Fax : +322 461 00 24, www.luxom.be

Test features

ICON TERMINOLOGY
-

- : Can mean 2 things:


- MIN number still needs to be written to the module or
- Module can not be detected. (Wiring problem on the network, faulty module,
problems with the RS232 or Ethernet gateway, too many modules on the network)
As soon as the problem is solved you Ping the module and the MIN on the icon
should disappear.

- : Data in the computer is different from that in the module. Data still needs to be written to the
module. This icon appears:
- After youve written the MIN number
- After youve changed data in the module OFF-line.
- When programming was interrupted
Note: The first time this icon appears on a module, this indicates that the module needs to be
formatted. This happens automatically and depending on the type of module it can take
a few minutes.

- : Normal, module OK. The data in the computer is the same as in the module.

- : Module in programming mode. (MIN led on the module is blinking)


Appears/Disappears only when you Ping the module.

Minelec

4
Minelec N.V., Isidoor Van Beverenstraat 59, 1702 Groot-Bijgaarden, Belgium
Tel : +322 460 31 75, Fax : +322 461 00 24, www.luxom.be

Test features