Beruflich Dokumente
Kultur Dokumente
Hardware Replacement
Hardware Version: HV1.0
ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://support.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright 2014 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.
Revision History
Revision No.
Revision Date
Revision Reason
R1.0
2014-11-17
First edition
SJ-20141127113509-004|2014-11-17 (R1.0)
Contents
About This Manual ......................................................................................... I
Chapter 1 ZXSDR R8872A Replacement .................................................. 1-1
Chapter 2 Cable Replacement................................................................... 2-1
2.1 Replacing the Grounding Cable........................................................................... 2-1
2.2 Replacing the Power Cable................................................................................. 2-3
2.3 Replacing the Optical Fiber ................................................................................ 2-4
2.4 Replacing the Antenna Feeder Jumper Cable ...................................................... 2-6
2.5 Replacing the AISG/MON Interface Cable............................................................ 2-8
Glossary .......................................................................................................... I
I
SJ-20141127113509-004|2014-11-17 (R1.0)
II
SJ-20141127113509-004|2014-11-17 (R1.0)
Intended Audience
This manual is intended for:
l
l
R8872A Replacement
R8872A.
Chapter 2, Cable
Replacement
Related Documentation
The following documentation is related to this manual:
l
l
Conventions
This manual uses the following conventions.
Note: provides additional information about a topic.
I
SJ-20141127113509-004|2014-11-17 (R1.0)
II
SJ-20141127113509-004|2014-11-17 (R1.0)
Chapter 1
Prerequisite
l
l
You have acquired the hardware configuration of the faulty ZXSDR R8872A, and
prepared a new ZXSDR R8872A with the same specifications as the faulty one.
You have recorded the information of all cable connections to the faulty ZXSDR
R8872A, such as the interfaces to which the optical fibers and antenna feeder
jumpers are connected. This information is used for correctly reconnecting the cables
to the new ZXSDR R8872A after the replacement.
Steps
1. Stop operating the equipment.
a. Inform the OMC administrator that the ZXSDR R8872A will be replaced, and ask
the administrator to block the cells corresponding to this site.
b. Power off the faulty ZXSDR R8872A.
2. Remove the faulty equipment.
a. Wear an ESD wrist strap, and ensure that the ESD wrist strap is grounded securely.
If no ESD wrist strap is available or no appropriate earthing point is available for
grounding the ESD wrist strap, wear antistatic gloves instead.
b. Disconnect all related cables from the faulty equipment, and stick a label on
the disconnected end of each cable. For how to disconnect the cables, refer to
Chapter 2 Cable Replacement.
c.
1-1
SJ-20141127113509-004|2014-11-17 (R1.0)
3. Install the equipment by referring to the ZXSDR R8872A Macro Remote Radio Unit
Hardware Installation.
a. Install the new chassis.
b. According to the information marked on cable labels, reinstall the removed cables.
4. Make power-on checks.
During equipment power-on, check whether the indicators are displayed in correct
statuses, and perform the corresponding operation according to different situations.
For the status description of each indicator on the ZXSDR R8872A, refer to the ZXSDR
R8872A Macro Remote Radio Unit Hardware Description.
l
l
5. Notify the OMC administrator to unblock the cells corresponding to this site.
6. Handle the faulty ZXSDR R8872A.
a. Put the faulty ZXSDR R8872A into a moisture-proof antistatic bag, mark the
equipment model, sector information, and fault information on a label, and stick
the label on the bag.
b. Put the bag containing the faulty device into a carton. Paste a label on the carton,
also describe the equipment model, sector information, and fault information.
c.
Contact the local office of ZTE for repairing the faulty equipment.
End of Steps
1-2
SJ-20141127113509-004|2014-11-17 (R1.0)
Chapter 2
Cable Replacement
Table of Contents
Replacing the Grounding Cable..................................................................................2-1
Replacing the Power Cable ........................................................................................2-3
Replacing the Optical Fiber .......................................................................................2-4
Replacing the Antenna Feeder Jumper Cable ............................................................2-6
Replacing the AISG/MON Interface Cable ..................................................................2-8
Steps
1. Record the statuses of all output switches in the external power supply cabinet, and
then turn off the output switch corresponding to the power cable to be replaced.
2. Remove the grounding screws on the grounding point of the equipment, and take off
the cable, see Figure 2-1.
2-1
SJ-20141127113509-004|2014-11-17 (R1.0)
3. Connect a new grounding cable. For detailed operations, refer to the ZXSDR R8872A
Macro Remote Radio Unit Hardware Installation.
4. Close the external power supply switch, and then observe whether power-related
indicators on the equipment are in proper statuses. For the description about
indicator statuses, refer to the ZXSDR R8872A Macro Remote Radio Unit Hardware
Description.
l Yes Power supply is normal. Go to the next step.
l No Troubleshoot the fault and connect the power cable again, or contact ZTE
technical support.
5. Handle the faulty cable.
a. Put the faulty cable into a moisture-proof antistatic bag, mark the cable type and
fault information on a label, and then stick the label on the bag.
b. Put the bag containing the faulty cable into a carton, and stick the same label on
the carton, providing necessary information for cable repair.
c.
Contact the local office of ZTE for handling the faulty cable.
End of Steps
2-2
SJ-20141127113509-004|2014-11-17 (R1.0)
Prerequisite
A spare power cable with the same type and length as the DC input power cable to be
replaced is available.
Steps
1. Take a record of the output switch status of the external power supply cabinet. Turn
off the output switch corresponding to power cable to be replaced.
2. Record the connection information at both ends of the old power cable, and then
disconnect the power cable. The following describes how to disconnect the power
cable from the ZXSDR R8872A.
a. Open the maintenance cavity, and loosen the power cable crimping clip at the
entrance of the maintenance cavity.
b. Press the top pole with the screwdriver, until the pole cannot spring back. Pull out
the power cable with the tubular terminal from the terminal block, see Figure 2-2.
Figure 2-2 Removing the Tubular Terminals
Note:
To pull out the plug, pull the ring at the plug with fingers and pull out the plug
gradually.
a. Install the new DC input power cable in accordance with the previously recorded
connection relationship. For detailed operations, refer to the ZXSDR R8872A
Macro Remote Radio Unit Hardware Installation.
b. Stick a label on the power cable.
The label of the new cable must contain the same information as that on the label
of the old cable.
c.
Use the multimeter to verify that no short circuit exists on -48 V and GND power
cables.
l Yes The power cable is connected properly. Go to the next step.
l No Troubleshoot the fault and connect the power cable again, or contact
ZTE technical support.
4. Close the external power supply switch, and then observe whether power-related
indicators on the equipment are in proper statuses. For the description about
indicator statuses, refer to the ZXSDR R8872A Macro Remote Radio Unit Hardware
Description.
l Yes Power supply is normal. Go to the next step.
l No Troubleshoot the fault and connect the power cable again, or contact ZTE
technical support.
5. Handle the faulty power cable.
a. Put the faulty cable into a moisture-proof antistatic bag, mark the cable type and
fault information on a label, and then stick the label on the bag.
b. Put the bag containing the faulty cable into a carton, and stick the same label on
the carton, providing necessary information for cable repair.
c.
Contact the local office of ZTE for handling the faulty cable.
End of Steps
Prerequisite
A spare optical fiber is available. The spare cable must be of the same type as the cable
to be replaced.
Steps
1. Disconnect the old cable.
a. Record the connection position at both ends of the optical fiber to be replaced,
and mark the positions.
b. Loosen the optical fiber crimping clip at the entrance of the maintenance cavity.
2-4
SJ-20141127113509-004|2014-11-17 (R1.0)
c.
Press the blue line card at the front of the optical fiber, and remove the optical fiber
and optical module (if it needs to be replaced) from the maintenance cavity, see
Figure 2-3.
Figure 2-3 Removing the Optical Fiber
Note:
If the replaced optical fiber is not damaged, cover the fiber connector with a dustproof
cap to prevent the connector getting dirty. If the fiber connector is dirty, use a piece of
dust-free cotton cloth or a fiber-cleaning box to clean it.
3. Check whether indicators on the optical fiber are in normal statuses. For the
description about indicator statuses, refer to the ZXSDR R8872A Macro Remote
Radio Unit Hardware Description.
2-5
SJ-20141127113509-004|2014-11-17 (R1.0)
l
l
Contact the local office of ZTE for handling the faulty cable.
End of Steps
Prerequisite
A set of RF cables are specified for different types of sites.
l
l
If RF cables are to be replaced for capacity expansion on a site, you can use a set of
RF cables in accordance with the site type.
If a single RF cable is to be replaced, you can select an RF cable with an appropriate
length from a set of cables according to the location where the cable is to be used.
Steps
1. Inform the OMC administrator that the antenna feeder jumper cable will be replaced.
Ask the administrator to block the cells in this site.
2. Disconnect the old cable.
a. Remove the waterproof tape from the antenna feeder jumper cable.
b. Use a wrench to unscrew the fastening screws of the antenna feeder cable
connector and the interface. Take off the connector carefully, see Figure 2-4.
2-6
SJ-20141127113509-004|2014-11-17 (R1.0)
Check whether the cable can send and receive RF signals properly.
l Yes The cable is connected properly. Go to the next step.
l No Troubleshoot the fault and connect the cable again, or contact ZTE
technical support.
c.
Contact the local office of ZTE for handling the faulty cable.
End of Steps
Steps
1. Remove the old cable, see Figure 2-5.
a. Record and mark the connection positions at both ends of the faulty AISG/MON
interface cable.
b. Turn the fastening screws on the cable connector in counterclockwise direction
with a screwdriver to loosen the connector.
c.
Pull out the connectors at both ends of the cable to take out the faulty cable.
2-8
SJ-20141127113509-004|2014-11-17 (R1.0)
Contact the local office of ZTE for handling the faulty cable.
End of Steps