Analysis of Cola

Michelle Pryce
Chemistry 101 Laboratory, Section
Instructor: Sabina Maskey
07 November 2007

My signature below indicates that this document represents my own


work. Excluding shared data, the information, thoughts, and ideas are
my own, except as indicated in the references.

Michelle Pryce

Abstract:
This purpose of this experiment is to analyze the phosphate content of three
different colas using a spectrophotometer. In order to accomplish this task,
several things must be done. First, proper usage of the spectrophotometer
must be determined. Then the spectrophotometer must be used in order to
determine the relationship between the color of a compound and the
wavelength of light absorbed. Once a relationship has been determined, a
correlation between the amount of light absorbed and the concentration of
phosphate in the solution must be determined. Several different
experiments were conducted in order to analyze the phosphoric acid content
since phosphoric acid cannot be directly measured. After several weeks of
investigation, both goals of the project were met, and it was determined that
Diet Coke had the greatest concentration of phosphate among the three
colas tested.
Introduction:
Background: This research group has been transferred to a major cola
company. The company has decided to engage in industrial espionage in
order to look at the formula for the rivals cola products. The major
ingredient that the company is interested in is the phosphate content of the
colas, since many people drink cola because they think the buffering
capacity of the phosphate will help to settle their upset stomach. The
purpose of this research is to analyze as many of the rivals coal products as

possible
(lab manual, 2005).
There were two goals to this research project. The first goal was to learn how
to accurately use the spectrophotometer. In learning to accurately use the
spectrophotometer, two distinct relationships must be determined. The first
relationship that had to be determined was the relationship between color of
a compound and the wavelength of the light absorbed. Once that was
determined, a second relationship had to be determined. The second
relationship was the correlation of the amount of light absorbed with the
concentration of the solution. Once those relationships were established,
then the second goal of determining the amount of phosphate contained in
each sample of the competitors cola could be analyzed.
This experiment consisted of four parts. Part one consisted of determining
the proper use of the spectrophotometer and using it correctly to determine
the relationship between color and wavelength of absorbance. Part two
consisted of making solutions of different colors and measuring them in the
spectrophotometer at several different wavelengths in order to determine
the relationship between color and absorbance. Once part two was
completed, part three could begin. In part three the determination of the
relationship between absorbance and concentration was established. Finally,
once the concentration of solutions that contained colors was clarified, then

that data could be used to analyze the phosphoric acid content of the
samples of cola.
Results:
Part one:
The first part of this experiment was to learn how to properly use the
spectrophotometer. A sample with known transmittance and absorbance
values was measured to determine the accuracy of the spectrophotometer.
Once the accuracy of the known values had been verified, then the actual
experiments could begin.
Part two:
In part two of the experiment, the relationship between color and wavelength
of absorbance could be measured.

In order to perform an analysis of color,

the samples had to be prepared. The samples were prepared as follows:


Sample 1blank, consisted only of water, sample 2one drop of red food
color mixed into 100 mL of water, sample 3---one drop of blue food color
mixed into 100mL of water, sample 4---a 1:1 mixture of the red and blue
solutions, and sample 50.001M KMnO4 from 1mL of 0.004M of KMnO4 and 3ml
of water. The samples were tested in the spectrophotometer at wavelengths
ranging from 350 nm to 700 nm at 25nm increments. The
spectrophotometer was blanked in between each increase of wavelength.
Results are summarized in table 1and graph1. Absorbency and molarity at

525nm were determined and results were summarized in table 2 and chart
2.
Part three:
In part three of this experiment, the relationship between absorbance of light
and concentration of solution was investigated. The relationship was
determined to be inversely proportional. As concentration of a sample was
decreased, absorbance increased. This relationship makes sense because
samples that are too heavily concentrated are much darker in color than
diluted samples, and therefore absorb all light emitted from the
spectrometer giving no reading. These results were summarized in the table
and graphs section.
Part four:
In part four of the experiment the phosphate content of the colas could
finally be determined. In order to accomplish the task, the colas first had to
be prepared. The carbon dioxide had to be removed, and the cola had to be
diluted in order to obtain meaningful readings. Since phosphoric acid does
not absorb UV light a solution of AVM was added to the diluted colas so that
the phosphoric acid could be measured.
Discussion:

This was a multi faceted experiment to determine the phosphate content in


several varieties of colas. However, phosphate content could not be directly
measured so a series of experiments were devised in order to assist in the
development of the new cola product. It was hypothesized that people
consume cola because of the phosphate contained in the product acts as a
buffer against stomach acid. In order to confirm or deny if this hypothesis is
correct, a comparison of phosphate content of known medications for upset
stomach such as pepto bismol and cola should have been done. In the
absence of such a comparison, it cannot be proven or disproven that people
drink cola solely to assuage an upset stomach.
Part one:
Part one of the experiment consisted only of the calibration of the
equipment. A sample with known values was placed in the
spectrophotometer and the reading of absorbance and percent
transmittance were taken and compared to the known values. This was a
critical step for the entire project as the calibration of the spectrophotometer
was of vital importance as it was the main piece of equipment used in this
project.
Part two:
In part two of the experiment, the relationship between color and wavelength
of absorbance was determined. Four samples of four different colors were
prepared as described in the experimental section. Results are summarized

in the tables and graphs section. Measurements were taken at several


increments of the light spectrum in order to determine the point of maximum
absorbance. As a reminder, the point of maximum absorbance is not the
same as the color of the sample. These results were compared to the table
on page 89 of the lab manual (Cooper, 2005) in order to determine the
relationship between color of light and wavelength of light.
Another important aspect of this portion of the experiment was the
determination of the relationship between transmittance and absorbance.
Transmittance is defined as the number of photons that pass through the
sample without being absorbed (Cooper, 2005) while absorbance is usually
thought of as the opposite of transmittance. In fact, the mathematical
relationship between absorbance and transmittance can be expressed in the
following formula: A=2.000-log (%T) (Cooper, 2005).
Part three:
Part three adds another layer of complexity to the experiment. In this
section of the experiment, the relationship between the absorbance of light
and concentration (molarity) of solutions were investigated. Concentrations
of most everyday items are way too concentrated to be analyzed in the
spectrophotometer. For this reason, samples used to measure concentration
must be diluted in order to be measured. As samples are diluted, the
molarity of the solution is decreased. This relationship is illustrated in the
tables and graphs section.

Part four:
All previous experiments have produced information needed to measure the
phosphate content in the colas. The colas must be diluted in order to be
analyzed in the spectrophotometer. At shelf concentration, the sample is
much too concentrated to be measured by the equipment. Once the cola
was diluted to a useable concentration, an indicator was added. For this
experiment, the indicator used was ammonium vanadomolybdate. AVM was
added to the solution because phosphoric acid cannot absorb ultraviolet or
visible light. However, with the indicator added, the solution undergoes a
chemical reaction that allows phosphoric acid to be measured.
Experimental Section:
Part one:
The spectrophotometer was turned on and allowed to warm up for a
minimum of 10 minutes. Two solutions were prepared. The first solution
prepared was a blank. The blank only contained the solvent and the known
sample contained the solvent and the solution. The difference in the amount
of light absorbed between the blank and the solution is the absorbance
amount since the absorbency of the solvent was the same in both samples.
The blank was placed in the spectrophotometer and % transmittance (%T)
was set to 0. Then a blank cuvette was placed in the spectrophotometer.
Then % T was set to 100%. Once the machine was calibrated, readings

could be obtained. The process had to be repeated for each change in


wavelength. This process allowed a known sample to be measured in the
spectrophotometer to access the accuracy of the device.

Part two:
Four different colored samples were made and tested in the
spectrophotometer. The samples were tested at several different
wavelengths and the absorbance was recorded in table 1. Sample 1
consisted only of water and was used as the blank. Sample 2 was made
from adding 1 drop of red dye to 100 ml of water. Then the solution was
stirred and poured into a 10ml flask. A cuvette was filled with the red
solution from the 10ml flask. Sample 3 was made from adding 1 drop of blue
dye to 100 ml of water. Then the solution was stirred and poured into a 10ml
flask. Sample 4 was made by taking 1:1 ratio of red solution and blue
solution and mixing them together. Sample 5 was made by diluting 0.004M
KmnO4 into 0.001M KmnO4 and then adding 1ml of solution to 3ml of water.
These four colored samples were analyzed at wavelengths ranging from
350nm to 700nm at 25nm increments.
Part three: The third step of this experiment consisted of two parts. Part one
was the determination of the analytical wavelength of phosphate and AVM
and part two was the creation of a calibration curve of phosphate/avm using

%T vs. molarity and A vs. molarity. In order to accomplish this portion of the
experiment, the stock KH2PO4 (M=0.101) had to be diluted. In order to
achieve the final concentration of 0.0002M, the stock was diluted in two
separate steps first going from 0.101M to 0.005M and then going from
0.005M to 0.0002M using the M1V1=M2V2 formula. Once the final
concentration of 0.0002M KH2PO4 was achieved, then the maximum point of
absorbance could be determined (see table % T 350-650). Calibration
curves were drawn for phosphate/avm using %T vs. molarity and A vs.
molarity values.
Part four:
In order to accomplish the task, the colas first had to be prepared. In order
to prepare the colas for analysis, dissolved carbon dioxide had to be removed
from the cola. The colas were boiled for approximately 20 minutes in glass
beakers. A watch glass was placed on top of the beakers in order to
minimize evaporation. Then the colas were diluted by a 50:1 ratio (50 mL of
water and 1mL of cola) and 10 mL of diluted cola was mixed with 5mL of
AVM. A sample of each cola/AVM mixture was placed in four separate
cuvettes and each sample was measured in the spectrophotometer. The
results for the 400nm wavelength are summarized in table 8 (Note: The
wavelength of maximum absorbency was determined to be 350nm, but the
spectrophotometer would not allow the samples to be measured at
wavelengths less than 400nm. Samples were prepared multiple times and

checked multiple times as well. The error was determined to be a


malfunction of the spectrophotometer and the experiment was allowed to
continue using the closest wavelength available which was 400nm).

Conclusion:
Several experiments were conducted in order for the company to spy on its
competitors. All goals of the experiment were met including learning to use
the spectrophotometer, determining the significance of relationship between
absorbance, wavelength and concentration, and analyzing the phosphate
content of all of the samples of the competitors products. It was concluded
that Diet Coke had the greatest phosphate content. In order for the new
product to have a greater buffering capacity against stomach acid than Diet
Coke, the new product should have higher phosphate content than Diet
Coke. The researchers also learned how to effectively use the new
spectrophotometers in order to conduct research and analysis.

References:

Cooper, M M. Cooperative Chemistry Laboratory Manual. 3rd


edition, 2005.
www.msds.gov
-ammonium vanadomolybdate
-potassium permanganate
-KH2PO4
Periodic Table of the Elements. SparkCharts. 2002.