Sie sind auf Seite 1von 50

Ivar Aasen Field Development Project pdQ

David Stone

28.05.2015

04L

05.05.15

As Built

DSF

EsFr

HFO

03L

17.03.15

As Built

EsFr

HFO

StWe

02L

19.11.14

As Built

EsFr

HFO

StWe

01E

01.07.14

Issued for review

EsFr

HFO

StWe

Rev.

Date

Reason for Issue

Prepared
by

Reviewed
Approved

by

by

110 KV SWBD CIRCUIT/WIRING DIAGRAM, SPARE

Package Title:

EICT Package

Area
Code:

System

Code:

M120

80

Project Tag Numbers:

80EC0505

No. of

Pages:

50

Project No.:

Supplier Document Number:

Rev.

C-00011

1
51PO-04193.210-K-105-00

04L

Purchase Order No:

Project Document Number:

Proj Rev.

1
DN02-S09011-E-XK-1005-00

04L

S09011

<1>

Item

Description

Page

Item

Description

Page

1.

Table of content

30.

Condition monitoring, Gas density sensors

30

2.

Single line drawing

31.

Capacitive voltage indicators

31

3.

Control voltage overview and distribution

32.

Arc detection sensors

32

4.

Control voltage distribution

33.

Voltage/current measurement unit (PAC 3200)

33

5.

Busbar A/B voltage measurement

34.

Overview diagram, Siprotec module 1 and 2

34

6.

Cabel voltage measurement

35.

Overview diagram, Siprotec module 3 and 4

35

7.

Disconnector Q61 for voltage transformer T5

36.

Overview diagram, Siprotec module 5 and 6

36

Current transformer T1 core 1 , 2, 3

37.

Overview diagram, Circuit breaker Q0 part 1

37

Current transformer T1 core 4, 5, 6

38.

Overview diagram, Circuit breaker Q0 part 2

38

10.

Control voltage distribution

10

39.

Overview diagram, Circuit breaker Q0 part 3

39

11.

Control voltage distribution, cabinet light

11

40.

Status switches, Circuit breaker Q0

40

12.

Control voltage and commands, Circuit Breaker Q0

12

41.

Overview diagram, Disconnector Q1

41

13.

Direct trip signals to circuit Breaker Q0

13

42.

Status switches, Disconnector Q1

42

14.

Trip circuit supervision

14

43.

Overview diagram, 3-position switch QZ2

43

15.

Control voltage and commands, Disconnector Q1

15

44.

Status switches, 3-position switch QZ2

44

16.

Control voltage and commands, 3-position switch QZ2

16

45.

Overview diagram, 3-position switch QZ9

45

17.

Control voltage and commands, Earth switch Q8

17

46.

Status switches, 3-position switch QZ2

46

18.

Control voltage and commands, 3-position switch QZ9

18

47.

Overview diagram, Earth switch Q8

47

19.

Heating

19

48.

Status switches, Earth switch Q8

48

D
20.

Breaker/switch positions

20

49.

Spare Terminals

49

21.

Breaker/switch positions

21

22.

Signals to Siprotec, Signals from CB Q0

22

23.

Signals to Siprotec, SF6 pressure alarm/trip

23

24.

Signals to Siprotec, Alarms and VTs online

24

25.

Signals to Siprotec, VT MCBs

25

26.

Signals to Siprotec, Trip signals

26

27.

Signals to Siprotec, Spare BI

27

28.

Breaker/switch status to BBdiff

28

29.

Trip signals from SAS, ESD and PSD

29

B
8.
9.

04L
As Built
03L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

DETNORSKE

02L
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E
Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue
Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Acceptance Code:

1
Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Table of content

StWe

Drawing Title:

Supplier

HFO

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-01

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

01

DN02-S09011-E-XK-1005-01

+E05

Sheets:

49

<1>

3
Busbar A

1 1 0kV, 1 250A, 40 kA(1 s)

Busbar B

-Q1

-QZ2

GC01

-Y1 , Y2 shunt coils

GC02

-Q0

In: 1 250A

P1

-T1
6
P2

L1 ,L2,L3:

600/1 A

2.5 VA Cl. 0.2FS5

2.5 VA Cl. 0.2S FS10

5 VA Cl. 5P20

10 VA Cl. 5P20

5 VA Cl. 5P20

5 VA Cl. 5P20

GC00

GC03

-QZ9

GC04

-T5

L1,L2,L3:

(90)110kV 110V

-Q61

GC05

3
3

10VA / Cl.0,2

10VA / Cl.0,2

-F1

-Q8

E
-Z1

Spare

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Single line drawing

StWe

02L

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-02

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

02

DN02-S09011-E-XK-1005-02

+E05

Sheets:

49

+UPS1

13

/.6

21

/.7

31

/.7

43

/.7

<>

22

32

230 VAC Supplied from UPS A

230 VAC Supplied from UPS B

230VAC Changeover UPS supply

K04: Changeover Relay

F230.1 : Socket outlet supply

MCB

B1 : Insulation monitoring of

110 VDC bus

13
23

44

A1

I > I >

14

/24.1

-K04
/.5

<6>

<5>

12

11
<8>

<7>

I > I >

As Built

F4:1

/1 0.4

1 7.03.1 5

DSF
EsFr

EsFr
HFO

Supplier

HFO

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Made by

Chc. by

SMOE

Appr. by

14
24
F6:1

/1 2.1

F230.1 :4

/1 1 .6

F6:3

/1 2.1

Acceptance Code:

Drawing Title:

Tag no.

Date:

P.O.Number

80EH0500

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

/24.2

I > I >

14
24
/24.3

F230.1:2

/1 1 .6

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Control voltage overview and distribution

StWe

02L

Date

C 3A

F5:3

/1 0.6

DETNORSKE

Description

-F6

F5:1

/1 0.6

F4:3

/1 0.4

05.05.1 5

I > I >
1

14
24
/24.3

2
As Built

C 3A

I > I >

C 3A

/24.2

I > I >

-F5

/24.2

14
22

C 6A

13
23

13
23

13
23

13
23

14
24

-F4

13
21

F6:4

/04.1

F3:3

/1 0.2

Issue

110VDC Supplied from UPS

F6: Spring charge Circut

breaker Q0 MCB

F6:2

/04.1

F3:1

/1 0.1

C 3A

03L

110VDC Supplied from UPS

F5: Trip coil 2 supply MCB

/24.1

14

-V2

/24.1

-V1

-F3

04L

-K04

/.5

-F230.1

1 1 0VDC Supplied from UPS

F4: Trip coil 1 supply MCB

32

44

Bender IR125Y-4

21

14

/24.1

-B1

13

/24.1

1 1 0VDC Supplied from UPS

F3: Instrument supply MCB

110VDC

Type of wire: Radox

11 0VDC

1 3

/24.1

-K04

/.5

22

-U4

PE

14

/24.1

L2

L1

L2

13

13

/24.1

L1
-U3

14

14

/24.1

L2

A-

13

/24.1

L1
-U2

-K04
/.5

A+

L2

R2

L1
-U1

R1

<4>

31

43

A2

-K04

/.5

14
24

C 10A

No. / Text

14

/24.1

14
24
2

I > I >

-F2

/24.1

C 10A

1
-F1

-X230

13
23

-K04

Yard cable

Yard cable
-X230

6
<3>

+UPS2

<2>

Please advice SWBD TAG and terminals

<1>

Please advice SWBD TAG and terminals

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-03

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

03

DN02-S09011-E-XK-1005-03

+E05

Sheets:

49

<2>

<1>

<3>

<4>

<5>

Circuit 604

<>

No. / Text

+82EL0123

F6:2
/03.6

1 1 0VDC Supplied from UPS

F7: disconnector switch Q1

motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F8: 3-postition switch QZ2

motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F9: Earthing switch Q8


motor and operation supply

MCB

1 1 0VDC Supplied from UPS

F1 0: 3-postition switch QZ9

motor and operation supply

MCB

230 VAC Supplied from Main

For heating and light

Yard cable

I >
I

I >

14
22

C 6A

/24.2

14
24

-F230.2

/24.2

I > I >

C 3A

13
23

2
-F10

I > I >

/24.2

14
24

13
23

2
C 3A

I > I >

13
23
14
24
/24.2

2
C 3A

I > I >

-F9

C 3A

-F8

-F7

14
24

13
23

13
21

-X230

F6:4
/03.6

/24.2

Type of wire: Radox

110 VDC

F7:1
/1 0.4

F9:1
/1 0.4

F8:1
/1 0.6

F7:3
/1 0.4

F8:3
/1 0.6

F1 0:1
/1 0.6

F230.2:2

/1 1 .2

F10:3
/1 0.6

F9:3
/1 0.4

F230.2:4

/1 1 .2

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Control voltage distribution

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-04

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

04

DN02-S09011-E-XK-1005-04

+E05

Sheets:

49

<1>

<2>

<3>

<>

Inter connection terminals

No. / Text

Details shown in document:

DN02-S09011-E-XK-1 006-01

110 V AC Busbar Voltage

voltage from ringloop

Busbar voltage MCB

Busbar B

Busbar voltage MCB

Busbar A

1 10V AC, 60HZ


VOLTAGE

BUSBAR A L1

2
L2

3
L3

B
B

B
B

I >

I >

I >

13
21

-XR1 1

110V AC, 60HZ

/25.3

A 1A

14
22

-F158

-XR1
5

VOLTAGE

BUSBAR B L1
6

L2

L3

I >

I >

I >

13
21

A 1A

/25.3

14
22

-F159

A1

A3

A5

U1

U2

U3

A2

A4

A6

Siprotec 7SJ85

C1
U7

U6
A14

-F21.3

/35.1

C2

A13

A11
U5
A12

-F21.3
/35.1

Siprotec 7SJ85

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Busbar A/B voltage measurement

StWe

02L

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-05

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

05

DN02-S09011-E-XK-1005-05

+E05

Sheets:

49

<1>

<2>

<4>

<3>

<5>

+80EH0500+E05

<>

2a2
4

32

03L

As Built

As Built

B6

1 7.03.1 5

EsFr

HFO

14
22
7

41

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

20

SMOE

Appr. by

18

14

13

-XT5

Acceptance Code:

Drawing Title:

Tag no.

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Cabel voltage measurement


.

DETNORSKE

StWe

As Built

Cable voltage transformer

core 2 110 kV/ 110 VAC

Spare

Supplier

02L

HFO

Cable voltage transformer

core 2 110 kV/ 110 VAC

Spare

EsFr

6
31

21

XT5:7

/33.5

DSF

Cable voltage transformer

core 2 110 kV/ 110 VAC

Class 0,2 star-star

Spare

XT5:6

/33.4

05.05.1 5

13
21

33

1
2

16

B5

XT5:8

/33.5

04L

Cable voltage transformer

core 1 110 kV/ 110 VAC

Cable voltage to PAC3200

multimeter

2n

2a1
31

11

41

31

I >

4
B

I >

-X722

XT5:5

/33.4

U3

B3
U2
B4

B1
U1
B2

Siprotec 7SJ85

I >

-XT5

-F21.1

/34.1

Cable voltage transformer

core 1 110 kV/ 110 VAC

Class 0,2 star-star

Cable voltage to

Siprotec protection relay

19

C 3A

6
A

13
21
14
22

2
A

12

10

-XT5

23

21

22

12
5

3
4
A

-F722

I >

11

11

41

2
B

I >

21

14
22
A

7
B

-X721

Yard cable

2a2
6

2n

2a1
5

2n

2a2
2

11
1

13
21

4
6
B

I >

6
31

13

32

C 3A

17

-XT5

-F721

I >

21

2
11

41

-X71 2

I >

2a1
1

1n

1a2
4
33

1
I >

3
B

-F712

6
31

-X720

-T5L3

15

-XT5

Yard cable

C 3A

I >

21

2
11

-X71 1

I >
4

I >

31

22
14
22

-F711

C 3A

1a1

1n

1a2
6
B

13
21

23

21

13

11

-X71 0

E03-W702

7x4 sq mm

-T5L2

E03-W703

7x4 sq mm

12

+80EH0500+E05

-T5L1

E03-W703

7x4 sq mm

1a1

1a2
2

1n

1a1
1

E03-W701

7x4 sq mm

-T5L3

-T5L2

-T5L1

No. / Text

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-06

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

06

DN02-S09011-E-XK-1005-06

+E05

Sheets:

49

<1>

<>

Line voltage transformer T5

isolator switch status

Isolating link not in

Isolating link in

Isolating link not in

X1:13
GY
BL
X1:14

X1:7
BN

BK

/24.6

/24.6

X1:8

X1:9
GY
BL
X1:10

X1:3
BK
BN
/24.4

X1:4

X1:15
GY
BL
X1:16

X1:5
BK
BN
X1:6

X1:11
GY

-BG2

BL

-BG1

X1:12

X1:1
BK

-BG4

BN

-BG3

X1:2

-T61

Isolating link for voltage


transformer T5

/24.4

Isolating link in

Isolating link not out

Isolating link out

Isolating link not out

Isolating link out

+80EH0500+E05

No. / Text

-BG1 , -BG2 is shown in deactivated position

-BG3, -BG4 is shown in activated position

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Disconnector Q61 for voltage transformer T5


Overview diagram

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-07

+E05

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

07

DN02-S09011-E-XK-1005-07

Sheets:

49

<2>

<1>

<3>

<>

No. / Text

+80EH0500+E05

-T1L1

-T1L1

-T1L1

L1

Current Transformer

Measurning current, Core 1

600/1 A 2,5VA Cl. 0,2S Fs5

measuring current to PAC3200

Current Transformer

Measurning current, Core 2

600/1 A 2,5VA Cl. 0,2S Fs5

Spare

Current Transformer

Protective current, Core 3

600/1A 5VA Cl. 5P20

protection current to

Siprotec

3S1

3S2

2S1

2S2

1S1

1S2

-T1 L2

-T1L2

-T1L2

L2

3S1

-T1L3

3S2

2S1

2S2

1S1

1S2

-T1L3

-T1L3

L3

E05-W603

7x4 sq mm

3S1

3S2

E05-W602
7x4 sq mm

2S1

2S2

49

41

11

21

31

32

-X630

22

12

49

41

21

31

11

std 4 sq mm

A
B

A
B

A
B

-XT1

A
B

A
B

A
B

A
B

310

311

321

331

Yard cable

332

-XT1

322

312

210

211

221

110

111

121

-XT1

131

Yard cable
132

Yard cable
122

std 4 sq mm

112

std 4 sq mm

32

-X620

22

12

49

41

231

232

11

21

31

222

212

32

-X61 0

22

+80EH0500+E05

12

1S1

1S2

E05-W601
7x4 sq mm

XT1:112

/33.3

A1

A3

A5

A7

I 2

I 3

I 4

A6

A8

XT1 :1 21

/33.3

A4

A2

XT1 :1 31

/33.4

I 1

-F21.1

/34.1

XT1:132

/33.4

Siprotec 7SJ85

XT1:1 22

/33.3

XT1:111

/33.3

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.15
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Current transformer T1 core 1 , 2, 3

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-08

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

08

DN02-S09011-E-XK-1005-08

+E05

Sheets:

49

<2>

<1>

<3>

<>

No. / Text

+80EH0500+E05

-T1L1

-T1L1

-T1L1

L1

Current Transformer

Measurning current, Core 4

600/1A 10VA Cl. 5P20

Spare

Current Transformer

Protective current, Core 5

600/1A 5VA Cl. 5P20

Protection current to

bus bar differential

Current Transformer

Protective current, Core 6

600/1A 5VA Cl. 5P20

Spare

6S1

6S2

5S1

5S2

4S1

4S2

-T1L2

-T1L2

-T1L2

L2

6S1

-T1L3

6S2

5S1

5S2

4S1

4S2

-T1L3

-T1L3

L3

E05-W606

7x4 sq mm

6S1

6S2

E05-W605
7x4 sq mm

5S1

5S2

B
A

49

41

11

21

31

32

22

A
B

A
B

-XT1

A
B

A
B

A
B

A
B

A
B

610

A
B

510

511

A
B

521

531

-XT1

Yard cable

532

-X660

std 4 sq mm

mm

522

A
B

12

49

41

11

21

31

std 4 sq mm

512

410

A
B

411

A
B

421

A
B

431

432

-XT1

422

Yard cable
412

Yard cable

611

std 4 sq mm

621

std 4 sq mm

32

-X650

22

12

49

41

631

632

11

21

31

622

612

32

-X640

22

+80EH0500+E05

12

4S1

4S2

E05-W604
7x4 sq mm

std 4 sq mm

Inter connection terminals

Details shown in document:

DN02-S09011-E-XK-1 006-01

-XR2

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Current transformer T1 core 4, 5, 6

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51 PO-041 93.21 0-K-1 05-09

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

09

DN02-S09011-E-XK-1005-09

+E05

Sheets:

49

X30:108

/26.2

110

116

/1 3.2

117

X30:107

/1 2.3

118

119

/1 2.6

111

X30:106

/1 2.4

-X30

112

108
109

113

107

102
1 03
104

X30:104 B

-X30

X30:111 B

X30:112 B
B

Control Voltage distrubution

110 VDC

Control Voltage Shunt coil 1

and close coil

110 VDC

Control Voltage Shunt coil 2

110 VDC

Control Voltage disconnector

switch Q1

110 VDC

Control Voltage 3-position

switch QZ2

110 VDC

Control Voltage Earthing

switch Q8

110 VDC

Control Voltage 3-position

switch QZ9

110 VDC

/04.2

X30:116

/1 2.6

F7:3

/1 6.6

130

136

/1 6.3

137

X30:127

/1 5.4

138

/1 6.2

139

X30:126

/1 5.2

-X30

131

127

X30:1 23 B

132

/1 5.6

128

X30:1 22 B

129

/1 5.4

X30:121 B

122

/1 5.2

-X30

133

126

-X30

F8:3

134

121

-X30

120

F8:1
125

F7:1

/04.3

/04.3

135

/04.1

X30:131 B
X30:132 B
X30:133 B

<5>

No. / Text

F5:3

114

105
106

101

100

<>

<4>

X30:136

/1 6.2

X30:1 37

/1 6.3

<6>

<7>

/04.4

/1 7.3

/1 7.4

/1 7.6

X30:141 B

X30:1 42 B

X30:143 B

-X30
B

X30:146

/1 7.3

/1 8.2

X30:147

/1 7.4

/1 8.3

/1 8.6

-X30
B

156

157

-X30

X30:151 B

X30:1 52 B
X30:153 B
B

F1 0:3

158

F1 0:1

/04.6

159

-X30

F9:3

150

/04.5

151

F9:1

/04.4

152

X30:1 56

/1 8.2

X30:157

/1 8.3

Acceptance Code:

1
04L
As Built
03L
As Built

05.05.1 5
17.03.15

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

02L
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E
Issued for review

01 .07.1 4

EsFr

HFO

StWe

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Control voltage distribution

DETNORSKE

Issue
Description

20

/03.4

153

19

154

/1 3.2

145

/33.5

X30:103 B

146

65
66
67

X30:54

/1 2.2

147

16
17
18

/25.3

X30:102 B

148

X30:53

/1 2.5

149

/33.5

50
61
62
63
64

B
X30:14

51

12

X30:12

13

/26.4

14

/26.3

15

52
59
60

B
X30:11

53

10

11

/25.1

123

X30:52

/1 2.4

124

X30:8

/20.2

X30:101 B

140

X30:51

F5:1

-X30

141

X30:7

142

-X30

143

X30:6

54

1
5

/03.4

F4:3

144

/25.3

X30:5

57

/25.3

58

/25.1

X30:4

68

/24.3

X30:3

/24.2

-X30

/24.1

X30:2

F4:1

/20.2

-X30

6
<3>

/03.3

/03.3

F3:3

55

F3:1

/03.1

56

/03.1

<2>

115

<1>

155

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-10

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

10

DN02-S09011-E-XK-1005-10

+E05

Sheets:

49

<1>

/03.7

9
10

X1 00:4
/.6

B
B

B X1 00:9

/.6

-X1 01

10

B X1 00:8

/.5

X1 00:3
/.5

X101 :2
/.6

B
B

-X230

Control Voltage distrubution

230 VAC from Main

Heater Low voltage control

cubicle with thermostat

230 VAC

Light Junction box

with door switch

230 VAC

Light Low voltage control

cubicle with door switch

230 VAC

Control Voltage distrubution

230 VAC from UPS

Heater Low voltage control

cubicle with thermostat

230 VAC

Socket outlet

230 VAC UPS

Yard cable

/.1
+80EH0500+S05
-X202

43

A
B

-X100

+80EH0500+S05

A
B

X100:3

/.1

X1 00:4

X101:7

/.7

-X230

No. / Text

F230.1:4

B X1 00:7

/.3

<>

-X1 01

-X100

/03.7

F230.1:2

<7>

<6>

F230.2:4

-X100

6
<5>

/04.7

F230.2:2

5
<4>

/04.7

<3>

<2>

/.6

-S1 01

-S100

-T1

/.5

-R101

X07:43

E05-W07

+80EH0500+E05
47x1,5 sq mm

43

X101:7

X07:44

B
A

PE

L2

L1

2
8

44
44

-X102

X202:6

E05-W07
47x1,5 sq mm

-X202

-R100

/1 9.1

-X100

+80EH0500+S05

-E100

142

-E101

141

X101:2

-Q0_4

/40.4

B
A

X1 00:8
/.2

X1 00:9

/.2

Yard cable

-X230

X202:44

/1 9.1

X100:7

/.2

Acceptance Code:

1
04L
As Built
03L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
1 9.1 1 .1 4

EsFr

HFO

StWe

01E
Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue
Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Control voltage distribution, cabinet light

and socket outlet

StWe

02L
As Built

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-105-11

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

11

DN02-S09011-E-XK-1005-11

+E05

Sheets:

49

Yard cable

B
A

207

B
A

206

205

B
A

204

203

202

201

200

X30:207

B13

B
A

B
A

-X4

/1 3.1

X4:2
/1 4.6
X4:3
B
B
B
A

B14
F21.1:B14
/1 4.5

/1 4.3

No. / Text

CB Q0 spring charge motor

110 VDC

Reset blocked motor Q0

Breaker operation counter Q0

Shunt trip 1 with trip

circuit supervision CB Q0

Close coil CB Q0

Shunt trip 2 with trip

circuit supervision CB Q0

/1 3.1
X3:2
/1 4.3

X3:3
B
B
B
B
A

-X30

BO 1 .3
F

B
A

X30:210

/1 4.6

210

-X3

F21.1:B9
/1 4.2

B12
BO 1.2

B11

BO 1.1

<>

F21.1:B13

/1 4.5

208

-H10

-S1

Siprotec 7SJ85

-F21.1
/34.1

X30:111

/1 0.5

X30:102

/1 0.3

F21.1:B10

<6>

F6:1
/03.6

X30:1 01

/1 4.2

<5>

B10

/1 0.3

F6:3

/03.6

<4>

4
<3>

209

3
<2>

2
<1>

B9

B
30

26

X06:30

X06:26

30

-X202

28

A
B

28

B
E05-W06
47x1,5 sq mm

X06:28

13

26

-X201

X07:13

E05-W07
47x1,5 sq mm

30

28

13

12

-X202

12

23
X06:23

4
X06:4

A
B

22

23

22

X06:3

E05-W06
47x1,5 sq mm

X07:1 2

X06:22

-X201

+80EH0500+S05

E05-W07

47x1,5 sq mm

M
DC

A1
A2

29 X07:29

A2
27 X06:27

A1

A1

-KK4

E05-W07

47x1,5 sq mm

-X202

29

27

X06:2
2
A

A2

X06:1
1
B

29

-X201

+80EH0500+S05

E05-W06
47x1,5 sq mm

-KK1

29 X06:29

-KK3

Control Voltage

X07:28

60s
A2

-M1

-Q0_1

/37.4
/37.4

A1

-Q0_2
/38.5

-Q0_1
/37.4

X07:30

+80EH0500+E05

04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

X30:107

/1 0.4

B
EsFr
HFO

/1 0.4

X30:106

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

X30:116

/1 0.6

Acceptance Code:

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Control voltage and commands


Circuit breaker Q0

StWe

02L

Drawing Title:

Supplier

HFO

215

214

213

212

-X30
X30:1 03

/1 0.3

211

Yard cable

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-105-12

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

12

DN02-S09011-E-XK-1005-12

+E05

Sheets:

49

<1>

L+ 110 DC

X30:104

<2>

<3>

<4>

/1 0.3

<>

21

12

-XR4

-XR1

Direct trip Shunt coil 1

ESD (Disabled)

Direct trip Shunt coil 1

PSD (Disabled)

Direct trip Shunt coil 1

Bus bar differential

Direct trip Shunt coil 1

Arc detection

Direct trip Shunt coil 2

ESD (Disabled)

Direct trip Shunt coil 2

PSD (Disabled)

Direct trip Shunt coil 2

Bus bar differential

+80EC0501

-XR4

13

22

-XR1

A
B

X3:2

/1 2.5

14

Arc detection

D1

-BO 4.1

D2

-K02.1

/29.4

Siprotec 7SS85

12
8

12
8

+80EC0501

-K01 .1
/29.2

XR4:3
/26.2

<5>

L+ 110 DC

X30:1 1 2

<6>

No. / Text

<7>

/1 0.5

23

-XR1

D3

-BO 4.2

D4

12
8

12
8

-K02.2

/29.5

-K01.2
/29.3

Siprotec 7SS85

+80EC0501

24

-XR1

X4:2

/1 2.7

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Wood Group

Installation: Ivar Aasen Field

Mustang
Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Direct trip signals to circuit breaker Q0

Shunt coil 1 and 2

StWe

02L

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-13

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

13

DN02-S09011-E-XK-1005-13

+E05

Sheets:

49

<1>

<2>

<>

A
/1 2.4

F21.1:B10

/1 2.5

/1 2.6

F21.1:B1 3

/1 2.4

F21.1:B1 4

A8

A7
BI 6.3

Circuit breaker Q0

Trip circuit supervision

Trip coil 2

110 VDC

BI 6.4

A6

A5

A4

/1 2.6

Siprotec 7SJ85

A1

A2

-F21.6

/36.4

X30:207
/12.5

F21.1:B9

Circuit breaker Q0

Trip circuit supervision

Trip coil 1

110 VDC

X4:3

BI 6.2

BI 6.1

A3

Siprotec 7SJ85

-F21.6
/36.4

1
/1 2.7

X3:3

No. / Text

X30:210

/1 2.7

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Trip circuit supervision


Shunt coil 1 and 2

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-14

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

14

DN02-S09011-E-XK-1005-14

+E05

Sheets:

49

<1>

<2>

X30:126

/1 0.4

<3>

<4>

X30:122

/1 0.3

/1 0.3

<>

No. / Text

Disconnector Q1

operation motor

110 VDC

Disconnector Q1

command off

110 VDC

Disconnector Q1

command on

110 VDC

Disconnector Q1

control voltage

110 VDC

X30:1 23

B14

B12
B

220

B13

E05-W1

47x1,5 sq mm

30

-X211

219

218

B1 1

+80EH0500+S05

B
A

Yard cable

E05-W1
47x1,5 sq mm

-X30

30

B
A

BO 4.2

32

-X21 1

BO 4.1

32

Yard cable

+80EH0500+S05

217

-X30

216

-F21.4

/35.4

Siprotec 7SJ85

X30:121

/1 0.3

X1:3

-Q1

/41 .4

.4

-QA2

A1

DC

-QA1

31

X1:31

X1:4

A2

A2

-M1

A1

-Q1
/41 .4

X1 :30

X1:32

X1 :6

X1 :5

+80EH0500+E05

-X21 1

31

+80EH0500+S05

E05-W1

47x1,5 sq mm

B
A

-X30

221

Yard cable

Acceptance Code:

X30:127
/1 0.4

04L
As Built
03L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
1 9.1 1 .1 4

EsFr

HFO

StWe

01 E
Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue
Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Control voltage and commands

Disconnector switch Q1

StWe

02L
As Built

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-15

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

15

DN02-S09011-E-XK-1005-15

+E05

Sheets:

49

<1>

<2>

X30:136

/1 0.6

<3>

<4>

<6>

<5>

X30:132

/1 0.5

/1 0.5

<>

No. / Text

X30:133

3-position switch QZ2

command disconnector off

110 VDC

3-position switch QZ2

command disconnector on

110 VDC

3-position switch QZ2

command earthing switch off

110 VDC

3-position switch QZ2

command earthing switch on

110 VDC

3-position switch QZ2

control voltage

110 VDC

C8

C6
C5

C7

226

227

228

C4
C3
225

B
A

-X222

A
B

A
B

E05-W2B
47x1,5 sq mm

E05-W2A
47x1,5 sq mm

-X212

30

-X212

32

+80EH0500+S05

A
B

E05-W2A
47x1,5 sq mm

B
A

30

A
B

3-position switch QZ2

operation motor

110 VDC

Yard cable

-X21 2

B
A

Yard cable

+80EH0500+S05

C2
-X30

BO 4.6

BO 4.5

C1

BO 4.4

224

BO 4.3

32

-X30

223

222

-F21.4

/35.4

Siprotec 7SJ85

X30:131

/1 0.5

E05-W2A

47x1 ,5 sq mm

X1:3

X2:30

-QZ2

/43.4
/43.4

A1

-QA2

-QA1

-X222

-X212

E05-W2A

47x1,5 sq mm

31

-X212

E05-W2B
47x1 ,5 sq mm

31

E05-W2A
47x1,5 sq mm
+80EH0500+S05

X1 :4

X2:31

X1:31

A2

DC

A2

-M1

A1

-QZ2
/43.4

X2:32

X1:30

X1:32

X1:6

X1:5

+80EH0500+E05

-X30

229

Yard cable

Acceptance Code:

X30:137
/1 0.6

04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Control voltage and commands

3-position switch QZ2

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-16

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

16

DN02-S09011-E-XK-1005-16

+E05

Sheets:

49

/1 0.4

<2>

<1>

X30:146

<3>

<4>

X30:142
/1 0.3

/1 0.3

<>

No. / Text

C14

Earthing switch Q8

command off

110 VDC

Earthing switch Q8

command on

110 VDC

Earthing switch Q8

control voltage

110 VDC

C13
B
A

30

3
X1:3

X1:32

-Q8

/47.4

/47.4

A1

-QA2

-QA1

31

X1:31

X1 :4

A2

DC

A2

-M1

A1

-Q8
/47.4

X1:30

6
X1:6

E05-W8

47x1,5 sq mm

+80EH0500+E05

A
B

B
32

-X224

30

+80EH0500+S05

32

X1:5

E05-W8
47x1,5 sq mm

B
A

Earthing switch Q8

spring charge motor

110 VDC

Yard cable

-X224

C12
-X30

Yard cable

+80EH0500+S05

C11

BO 4.8

234

BO 4.7

233

231

-X30

230

-F21.4

/35.4

232

X30:141
/1 0.3

Siprotec 7SJ85

X30:143

-X224

31

+80EH0500+S05

E05-W8

47x1,5 sq mm

B
A

-X30

235

Yard cable

Acceptance Code:

X30:147
/1 0.4

04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Control voltage and commands

Earth switch Q8

StWe

02L

Tag no.

Signature:

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-105-17

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

17

DN02-S09011-E-XK-1005-17

+E05

Sheets:

49

<1>

<3>

<2>

X30:156

/1 0.6

<4>

<5>

<6>

X30:152

/1 0.5

/1 0.5

<>

No. / Text

X30:153

242

C3
B

241

C1
240

3-position switch QZ9

operation motor

110 VDC

3-position switch QZ9

command disconnector off

110 VDC

3-position switch QZ9

command disconnector on

110 VDC

3-position switch QZ9

command earthing switch off

110 VDC

3-position switch QZ9

command earthing switch on

110 VDC

3-position switch QZ9

command control voltage

110 VDC

C4

C2

B14
B13
239

E02-W9A

47x1,5 sq mm

X1 :3

X2:32

X2:30

E02-W9B
47x1,5 sq mm
X1:32

-X213

30

-X223
A

E02-W9A
47x1,5 sq mm

-QZ9

/45.4

/45.4

A1

DC

-QA1

-X223

E02-W9A

47x1,5 sq mm

-X213

E02-W9B

47x1,5 sq mm

31

-X21 3

31

E02-W9A

47x1,5 sq mm

+80EH0500+S05

X1:4

X2:31

X1:31

A2

-QA2

A2

-M1

A1

-QZ9

/45.4

/45.4

32

-X213
A
B

30

+80EH0500+S05

X1 :6

+80EH0500+E05

X1 :5

E02-W9A
47x1,5 sq mm

X1:30

A
B

Yard cable

-X213

B11
-X30

Yard cable

+80EH0500+S05

B12

BO 5.4

BO 5.3

BO 5.2

238

BO 5.1

32

-X30

237

236

-F21.5

/36.1

Siprotec 7SJ85

X30:151

/1 0.5

243

Yard cable

-X30
A

X30:157

/1 0.6

04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Acceptance Code:

Supplier

HFO

DETNORSKE

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Appr. by

Tag no.

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Control voltage and commands


3-Position switch QZ9

StWe

02L

Drawing Title:

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-18

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

18

DN02-S09011-E-XK-1005-18

+E05

Sheets:

49

<1>

<2>

<3>

<5>

<4>

+80EH0500+S05

<>

No. / Text

/1 1 .1

Heater Circuit breaker Q0

230 VAC

Heater Disconnector Q1

230 VAC

Heater 3-Position switch QZ2

230 VAC

Heater 3-Position switch QZ9

230 VAC

Heater Earthing switch Q8

230 VAC

E05-W2A
47x1,5 sq mm

E05-W9A
47x1,5 sq mm

E05-W1
47x1,5 sq mm

47x1,5 sq mm

-X224

E05-W8
47x1,5 sq mm

-X213

-X212

-X211

E05-W07

X202:44
-X202

X1:1

X1:1
-EB2

-EB1

2
-EB2

-EB2

-EB1

-EB1

X1:2

E05-W9A
47x1,5 sq mm

X1:2

X1:2

E05-W2A
47x1,5 sq mm

X1:2
E05-W1
47x1,5 sq mm

E05-W07
47x1,5 sq mm

X07:6
6

-EB2

-EB1

-EB3

-Q8

/47.4

-QZ9
/45.4

-EB2

-QZ2
/43.4

-Q1
/41 .4

-EB1

X1:1

X1:1

X07:5

X07:3

X07:4

+80EH0500+E05

-Q0_1
/37.4

E05-W8

47x1,5 sq mm

-X213

B
A

-X224

-X212

-X211

-X202

+80EH0500+S05

E
X202:6

/1 1 .4

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Heating
.

StWe

02L

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-19

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

19

DN02-S09011-E-XK-1005-19

+E05

Sheets:

49

<1>

<3>

<2>

<5>

<4>

<6>

<7>

<8>

L+ 110 DC

X30:2

<>

250

/1 0.1

-X30

Circuit breaker Q0 off

Status contact

110 VAC

Circuit breaker Q0 on

Status contact

110 VAC

46

Disconnector Q1 off

Status contact

110 VAC

X2:46

Disconnector Q1 on

Status contact

110 VAC

43

Yard cable

3-position switch QZ2

disconnector off

Status contact

110 VAC

3-position switch QZ2

disconnector on
Status contact

110 VAC

46

7
X2:7
41

43

-QZ2_2

/44.4

46

E05-W2B
47x1,5 sq mm

44

X2:8

X2:9
9

-X222

E05-W2B

47x1,5 sq mm

42

44
X1:9
9

X1:46

7
42
X1:8
8

-X21 2

E05-W2A

47x1,5 sq mm

-BG2

X1:9
9

-X222

X1:7
-QZ2_1
/44.4

44

X1:8

42
-X21 1

E05-W1

47x1 ,5 sq mm

42

46

46
46
X1:46

E05-W2A
47x1,5 sq mm

-BG1

114
X06:42
41

112
X06:40
40
40

-X201

+80EH0500+S05

-BG1

E05-W06

47x1,5 sq mm

41

-Q1_1
/42.4

-BG1

7
X1:7

E05-W1
47x1,5 sq mm

41

41
X06:41

111

-Q0_4
/40.4

A
B

113

+80EH0500+E05

39

E05-W06
47x1,5 sq mm

X06:39

-X21 2

43

-X21 1

41

39

-X201

3-position switch QZ2

earthing switch off

Status contact

110 VAC

3-position switch QZ2

earthing switch on

Status contact

110 VAC

307

D14
BI 1 .8

BI 1 .7

D11

D10

D13

BI 1 .6

D9

D8

D7

BI 1 .5

D12

306

305

304

303

BI 1 .4

D3

BI 1 .3

D6

D5

C14

C13

BI 1 .2

D2

BI 1 .1

A
B

D1

-F21.1

/34.1

Siprotec 7SJ85

D4

302

301

300

-X30

Yard cable

X222:46

/21 .1

+80EH0500+S05

No. / Text

F21.1:D12

/21 .1

L-

X30:51 /1 0.2

Acceptance Code:

1
04L
03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Supplier

HFO

DETNORSKE

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Breaker/switch positions

Status to Siprotec

StWe

02L

Drawing Title:

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-20

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

20

DN02-S09011-E-XK-1005-20

+E05

Sheets:

49

<1>

<2>

<4>

<3>

<5>

<6>

<7>

<8>

L+ 110 DC

<>
1

3-position switch QZ9

disconnector off

Status contact

110 VAC

3-position switch QZ9

disconnector on

Status contact

110 VAC

3-position switch QZ9

earthing switch off

Status contact

110 VAC

A
+80EH0500+S05

X202:15

/22.1

15

10

46
X07:15

Earthing switch Q8 off

Status contact

110 VAC

Earthing switch Q8 on

Status contact

110 VAC

On-spring unloaded Q0

Fault contact

110 VAC

General lockout SF6 Q0

Fault contact

110 VAC

21

22
X07:16
A

-X202

3-position switch QZ9

earthing switch on

Status contact

110 VAC

46

X07:11
7

E05-W07

47x1,5 sq mm

46

-X224

4
-K10

12

14
X1:9

X1:8

X2:9
46
A

E05-W8
47x1,5 sq mm

7
X07:10

-BG1 6
12

44

42
-X223

46

7
8

-X213

+80EH0500+S05

E05-W2B
47x1,5 sq mm

81

-Q0_3
/39.1

13

X1:7

X1 :46

E05-W07

47x1,5 sq mm

E05-W2A
47x1,5 sq mm

A
B

46

11

-Q8_1
/48.4

-X202

-BG1

X2:8

X1:9

42
X1:8

46

46
46
X2:46

E05-W8
47x1,5 sq mm

-BG2
44

-BG1

A
B

43

X2:7
-QZ9_2
/46.4

43

41

-QZ9_1
/46.4

E05-W2B
47x1,5 sq mm

-X224

7
X1:7

A
B

X1:46

+80EH0500+E05

E05-W2A
47x1,5 sq mm

B
46

-X223

41

-X213

46

X222:46
/20.7

No. / Text

Yard cable

315

D11

D10

BI 3.8

D12

D8

BI 3.7

BI 3.6

D14

B
D13

D7
BI 3.5

314

313

312

311
D6
BI 3.4

D3

A
B

D4

BI 3.3

BI 3.2

D9

C14

C13

A
B

D2

BI 3.1

A
B

D1

-F21.3

/35.1

Siprotec 7SJ85

310

D5

-X30

309

308

F21.1:D1 2
/20.7

F21.3:D12

/22.1

L-

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

DETNORSKE

02L

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Date:

P.O.Number

80EH0500

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Breaker/switch positions

Status to siprotec

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-105-21

Installation: Ivar Aasen Field

Development Project - PDQ Platform

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

21

DN02-S09011-E-XK-1005-21

+E05

Sheets:

49

<1>

<2>

<3>

<4>

<6>

<5>

<7>

L+ 110 DC

<>

+80EH0500+S05

X202:15
/21 .7

Spring charge motor MCB Q0

(MCB inside of breaker)

Status contact (alarm high)

110 VAC

Motor running time

supervision Q0

Fault contact (alarm high)

110 VAC

Loss of SF6 Q0

Fault contact (alarm high)

110 VAC

40

40

40

40
13

-Q8

/47.4

Disconnector Q1

crank inserted

Status contact

110 VAC

3-position switch QZ2

crank inserted

Status contact

110 VAC

3-position switch QZ9

crank inserted

Status contact

110 VAC

Earthing switch Q8

crank inserted

Status contact

110 VAC

14

14

-BG22

41

X1 :41

X1:41
E05-W9A
47x1,5 sq mm

X1 :40

X1 :40

E05-W8

47x1,5 sq mm

13

40
14
41

E05-W2A
47x1,5 sq mm

-BG23

X1 :41

X1:41

X06:11
11

-QZ9
/45.4

-BG23
14

11

X06:10
10

E05-W1
47x1,5 sq mm

E05-W9A
47x1 ,5 sq mm

13

13
-BG23

X06:12

22

-QZ2
/43.4

-X224

X1:40

X1:40
-BP1

12

E05-W06
47x1,5 sq mm

E05-W2A
47x1,5 sq mm

41

-K67
25

-F1

-Q1
/41 .4

13
12

21

-Q0_2
/38.5

26
28

-X223

40

E05-W1
47x1,5 sq mm

X06:14

E05-W06
47x1,5 sq mm
+80EH0500+E05

14

-X212

41

40

-X211

40

-X201

1
X224:40

/23.1

14

E05-W8
47x1,5 sq mm

-X223

-X30

A5

A8
BI 4.4

A6

A7

-F21.4

/35.4

BI 4.3

A4

Crank inserted

common alarm (alarm high)

110 VAC

Siprotec 7SJ85

A2

A1

BI 4.2

322

A
B

A3

BI 4.1

318

317

316

Siprotec 7SJ85

Yard cable

-X30

-F21.4
/35.4

Yard cable

-X224

41

-X212

41

-X211

41

41

11

12

10

+80EH0500+S05
-X201

No. / Text

E
F21 .4:A6

/23.1

F21 .3:D1 2
/21 .7

L-

Acceptance Code:

1
04L
As Built
03L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
1 9.1 1 .1 4

EsFr

HFO

StWe

01E
Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue
Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Signals to Siprotec

StWe

02L
As Built

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-22

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

22

DN02-S09011-E-XK-1005-22

+E05

Sheets:

49

<1>

<2>

<3>

<4>

<5>

<6>

<7>

7
<9>

<8>

<10>

L+ 110 DC

<>

No. / Text

+80EH0500+S05

X224:40

/22.6

-X99
A

X99:14
14

E05-W95

7x1 ,5 sq mm

SF6 Signals from BP1

GC01 (Q1 chamber)

SF6-loss warning

110 VAC

SF6 Signals from BP1

GC01 (Q1 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC02 (QZ2 Chamber)

SF6-loss warning

110 VAC

E05-W94

7x1,5 sq mm

13

11

A
B

E05-W93
7x1,5 sq mm

10

E05-W92

7x1 ,5 sq mm

E05-W91

7x1,5 sq mm

/24.3

+80EH0500+E05

23
22

13
12

23
22

-BP5

21

SF6 Signals from BP1

GC02 (QZ2 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC03 (QZ9, Q8, Z1 Chamber)

SF6-loss warning

110 VAC

E05-W95

7x1,5 sq mm

25

24

SF6 Signals from BP1

GC03 (QZ9, Q8, Z1 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC04 (T5 Chamber)

SF6-loss warning

110 VAC

SF6 Signals from BP1

GC04 (T5 Chamber)

SF6-loss critical (trip)

110 VAC

SF6 Signals from BP1

GC05 (F1 Chamber)

SF6-loss warning

110 VAC

10

SF6 Signals from BP1

GC05 (F1 Chamber)

SF6-loss critical (trip)

110 VAC

35

34

33

32

22

21

31

23

+80EH0500+S05

-X99

A13

A12

328

B4

B3
BI 4.9

BI 4.1 0

B6

BI 4.8

A
B

B2

B1

A10

BI 4.7

-X30

BI 4.6

327

326

B5

A9
BI 4.5

A11

-F21.4

/35.4

Siprotec 7SJ85

-X30

A14

325

324

323

-X30

L-

Acceptance Code:

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF

EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Description

Made by

Date

SMOE

Chc. by
Appr. by

Tag no.

Wood Group

Mustang
Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Signals to Siprotec

Pressure alarm/trip from GIS chambers

StWe

02L

Issue

F21 .4:B6

/24.1

F21.4:A6

/22.6

04L

Yard cable

11

21

13
12

E05-W94

7x1,5 sq mm

-BP5

21

E05-W93

7x1 ,5 sq mm

-BP4

11

21
2

-BP4

11

E05-W92

7x1,5 sq mm

-BP3

+GC05

-BP3

23
22

+GC04

13
12

23
22

13
12

-BP2

11

21

P
11

E05-W91

7x1,5 sq mm

-BP2

-BP1

23
22

13
12

-BP1

+GC03

+GC02

+GC01

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-23

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

23

DN02-S09011-E-XK-1005-23

+E05

Sheets:

49

<2>

<1>

<3>

<4>

<5>

<6>

L+ 110 DC

X30:3

/1 0.1

X30:4

/1 0.1

X30:5

<>

/1 0.1

No. / Text

+80EH0500+S05

-X261

X99:14

/23.7

-X261

-X501

Line voltage transformer

connected (Core 2)

Common alarm VT MCB and

VT disconnector

SPARE BI

Yard cable

-F721

-X30

-X501

-X30

D8

D7

BI 4.16

BI 4.1 5

D9

BI 4.1 4

BI 4.13

D12

D11

D6

D5

D10

-X501

330

-X30

14

Line voltage transformer

connected (Core 1)

Common alarm VT MCB and

VT disconnector

-F711

B8

80

Yard cable

13

-X501

10 14

X1 :8
8

-X261

B10

B9

Common MCB alarm critical

Trip coil 1 or 2 MCB fault

+80EH0500+S05
8

-X261

BI 4.1 2

B7

Siprotec 7SJ85

BI 4.1 1

7
BN

5
14
6

E05-W61

25x1,5 sq mm

14

13 14

-X501

-F21.4

/35.4

Common MCB alarm

-F722

14

+80EH0500+S05

-F230.2

/04.7

-X501

-BG2

329

13 14
-F230.1

/03.7

13

BN
X1:4

13 14
-U4

/03.4

E05-W61

25x1,5 sq mm

-F1 0

/04.5

-X501

13 14

-U3

/03.3

-X501

+80EH0500+S05

-F712

13

13 14
-F9

/04.4

-T61

/07.3

14

13 14

-F8

/04.3

13 14

-U1

/03.1

-U2

/03.2

+80EH0500+S05

-BG1

13 14

-F7

/04.1

X1:7

X1:3
-T61

/07.3

+80EH0500+E05

13 14

-F2

/03.3

+80EH0500+E05

BK

E05-W61

25x1,5 sq mm

-F5

/03.4

E05-W61

25x1,5 sq mm

BK

-F6

/03.6

Control voltage failure

110 VDC bus and voltage

converter 230 VAC/110 VDC

13
13 14

-F1

/03.1

14

13
13 14

-F4

/03.3

13 14

-F3

/03.1

13 14

-B1

/03.5

13 14

11

1
A

13

F21.4:B6

/23.5

LAcceptance Code:

1
04L
03L

As Built
As Built

05.05.1 5
DSF
1 7.03.1 5
EsFr

EsFr
HFO

DETNORSKE
As Built

1 9.1 1 .1 4
EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4
EsFr

HFO

StWe

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Signals to Siprotec
Alarms and breaker failure

StWe

02L

Issue

Drawing Title:

Supplier

HFO

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-24

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

24

DN02-S09011-E-XK-1005-24

+E05

Sheets:

49

<1>

<2>

<3>

<4>

<6>

<5>

<7>

L+ 110 DC

X30:6

X30:7

/1 0.1

X30:8

/1 0.1

<>

/1 0.1

Control power to Siprotec

7SJ85

110 VDC

Busbar A voltage MCB F158

fault contact

110 VDC

Busbar B voltage MCB F159

fault contact

110 VDC

Spare

Spare

Backup ARC detection.

(Only active if QZ2D is

closed)

Arc detection

Trip of Edvard Grieg

-F158
/05.6

82

81

-X30

A10

A9

BI 5.6

BI 5.5

A12

A4

A11

BI 5.4

A6

BI 5.3

A5

BI 5.2

A8

A7

A2

A1
BI 5.1

A3

Siprotec 7SJ85

B1
B2

Siprotec 7SJ85

14

14

-F159

/05.4

-X30

-F21.5

/36.1

13

13

-F21.2
/34.4

No. / Text

F21.5:A1 2

/26.1

L-

X30:52 /1 0.2

X30:53 /1 0.2

Acceptance Code:

1
04L
As Built
03L
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
1 9.1 1 .1 4

EsFr

HFO

StWe

01E
Issued for review

01.07.14

EsFr

HFO

StWe

Issue
Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Signals to Siprotec

StWe

02L
As Built

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-25

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

25

DN02-S09011-E-XK-1005-25

+E05

Sheets:

49

<2>

<1>

<3>

<4>

<5>

<6>

L+ 110 DC

X30:11

X30:12

/1 0.1

<>

/1 0.1

Spare BI

110 VDC

Arc detection Trip

110 VDC

ESD Trip. Status and

trip signal to IED

110 VDC

PSD Trip. Status and

trip signal to IED

110 VDC

-K02.2

/29.5

84

BI 5.8

BI 5.9

BI 5.1 0

BI 5.1 1

B10

B9

B3

B2

BI 5.1 2

B8

B7

B5

A14

B6

B1

B4

A13

Siprotec 7SJ85

BI 5.7

85

-X30

-F21.5

/36.1

F21.5:A12
/25.7

F21.5:B10

/27.2

X30:108

/1 0.4

Acceptance Code:

L04L

03L

As Built
As Built

1
05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

02L

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Signals to siprotec

Trip signals

DETNORSKE

Issue

Spare BI

11
7

11
7
-K01.2
/29.3
3

83

-X30

Spare BI

-K02.1

/29.4

-K01.1
/29.2

XR4:3

11
7

11
7

/1 3.4

No. / Text

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-26

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

26

DN02-S09011-E-XK-1005-26

+E05

Sheets:

49

<1>

<3>

<2>

<4>

L+ 110 DC

<>

No. / Text

Spare BI

Spare BI

Spare BI

Spare BI

86

-X30

B
A

B
A

89

88

87

B
A

D12

D11

BI 5.1 6

D9

BI 5.1 5

D10

D6

D5

BI 5.1 4

D8

BI 5.1 3

D7

-F21.5

/36.1

Siprotec 7SJ85

F21.5:B10

/26.7

L-

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Signals to Siprotec
Spare BI

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-27

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

27

DN02-S09011-E-XK-1005-27

+E05

Sheets:

49

<1>

<2>

<3>

<4>

<5>

<6>

<7>

331

<>
-X30

110 VDC L+

From Bus-Coupler E01

Circuit breaker Q0 off

To Bus-Coupler E01

Status contact

110 VAC

12

10

12
X1:12

3-position switch QZ1

disconnector off

To Bus-Coupler E01

Status contact

110 VAC

53

10

Circuit breaker Q0 on

To Bus-Coupler E01

Status contact

110 VAC

X1:10

E05-W2A
47x1,5 sq mm

X1 :1 0

X1:12

-QZ2_1
/44.4
/44.4

53

121

51

-Q1_1
/42.4

123

X06:43

X06:45

+80EH0500+E05

-Q0_4
/40.4

-BG1

-BG1

-BG1

54

X1:11

X1 :1 3

52

54
X1:13

X1 :1 1

X06:46

X06:44

52

122

124

13

E05-W2A
47x1,5 sq mm

11

13

E05-W1
47x1,5 sq mm

11

46

44

6
E05-W06
47x1,5 sq mm

51

E05-W1
47x1,5 sq mm

-X212

12

45

43

12

-X211

10

10

43

-X201

E05-W06
47x1,5 sq mm

+80EH0500+S05

45

No. / Text

13

-X212

11

13

-X211

11

44

-X201

46

+80EH0500+S05

3-position switch QZ1

disconnector on

To Bus-Coupler E01

Status contact

110 VAC

3-position switch QZ2

disconnector off

To Bus-Coupler E01

Status contact

110 VAC

3-position switch QZ2

disconnector on

To Bus-Coupler E01

Status contact

110 VAC

A
B

337

336

335

334

-X30

333

332

Yard cable

Inter connection terminals

B
A

B
A

28

27

26

25

24

-XR3

22

23

Details shown in document:

DN02-S09011-E-XK-1006-01

B
A

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE

Breaker/Switch Status to Bus Bar Differential IED

StWe

DETNORSKE

02L

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-28

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

28

DN02-S09011-E-XK-1005-28

+E05

Sheets:

49

<1>

<2>

<>

No. / Text

ESD trip from SAS

24 VDC

PSD trip from SAS

24 VDC

+SAS

A
B

Yard cable

-X24

Yard cable

-X24

-K02.2

/.5

-K02.1
/.4

-K01.2
/.3

-K01.1
/.2

-K01.1
7
/26.3 11
8
/1 3.2 12
9
13
10
14

-K01.2
3
4
5
6

7
/26.3 11
8
/1 3.2 12
9
13
10
14

-K02.1
7
/26.4 11
8
/1 3.2 12
9
13
10
14

3
4
5
6

-K02.2

7
/26.4 11

8
/1 3.2 12

5
6

9
13

10
14

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Trip signals from SAS


ESD and PSD

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-29

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

29

DN02-S09011-E-XK-1005-29

+E05

Sheets:

49

<1>

<2>

<3>

<4>

<5>

<6>

<>

Preasure measurement

to SAS

GC00 (CB, T1)

6,5 - 20 mA

Preasure measurement

to SAS

GC01 (Q1)

6,5 - 20 mA

Preasure measurement

to SAS
GC02 (QZ2)

6,5 - 20 mA

Preasure measurement

to SAS

GC03 (QZ9, Q8, Z1)

6,5 - 20 mA

Preasure measurement

to SAS

GC04 (T5)
6,5 - 20 mA

B
A

12

11

B
A

10

+SAS

B
A

Yard Cable

+GC00
-BP1

62

Preasure measurement

to SAS

GC05 (F1)

6,5 - 20 mA

bn

bk

E05-W95S

2x0,35 sq mm

6,5-20 mA

+
+GC04
-BP4.

61

60
bn

E05-W94S
2x0,35 sq mm

A
B

+GC03
-BP3.

6,5-20 mA

6,5-20 mA

bk

bn

E05-W93S
2x0,35 sq mm

59

bk

bn

bk

58

57

56

55

54
bn

+GC02
-BP2.

A
B

6,5-20 mA

+
+GC01
-BP1.

A
B

E05-W92S
2x0,35 sq mm

6,5-20 mA

+80EH0500+E05

A
B

E05-W91S
2x0,35 sq mm

6,5-20 mA

53

bn

E05-Q0-WG1S
2x0,35 sq mm

A
B

bk

bk

51

52

+80EH0500+S05

-X99

No. / Text

+GC05

-BP5.

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Condition monitoring
Gas density sensors

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-30

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

30

DN02-S09011-E-XK-1005-30

+E05

Sheets:

49

<1>

<>

No. / Text

Capacative voltage

Indicator

L3

L1

L2

Sensors in cable terminations Female part

L3

L1

L2

-A51

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Capacitive voltage indicators


.

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-31

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

31

DN02-S09011-E-XK-1005-31

+E05

Sheets:

49

3
<2>

<1>

4
<3>

6
<5>

<4>

<6>

<>

-F23:BC91

-F23:BC1 05

-F23:BC105

-F23:BC1 05

-F23:BC105

Fiber optical arc detection

sensor

Q1 chamber

Fiber optical arc detection

sensor

QZ2 chamber

Fiber optical arc detection

sensor
QZ9, Q8, Z1 chamber

Fiber optical arc detection

sensor

T5 chamber

Fiber optical arc detection

sensor

F1 chamber

Fiber optical arc detection

sensor

Q0 chamber

Fiber optical wire

Fiber optical wire

Fiber optical wire

Fiber optical wire

Fiber optical wire

+80EC0501

-F23:BC21

No. / Text

Fiber optical wire

+GC01
-F10

+GC02
-F10

+GC03
-F1 0

+GC04
-F10

+80EH0500+E05

+GC05
-F10

+GC00

-F1 0

All fiber optical wires

are directly connected

to the arc detection unit in

cublicle E01 (bus tie LVCC)

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Arc detection sensors


.

StWe

02L

Tag no.

Signature:

28/05/15

David Stone

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-32

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

32

DN02-S09011-E-XK-1005-32

+E05

Sheets:

49

<1>

<>

No. / Text

Voltage/current measurement

PAC 3200 multimeter

/08.2

XT1:131

B
/08.2

XT1:132

/08.2

/06.4

XT1:121

XT5:8

/08.2

/06.3

XT1 :122

XT5:7
/08.3

/1 0.2

/06.3

XT1:111

X30:54

XT5:6

/08.2

/1 0.1

/06.3

XT1:112

X30:14

N/-

L/+

X2:N

X2:V3

X2:V2

X2:V1

X1 :IL3 i

X1 :IL3 k

X1 :IL2 i

X1:IL2 k

X1 :IL1 i

-P02

X1 :IL1 k

XT5:5

DC:110-340 V

AC:95-240 V

PAC 3200

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Voltage/current measurement unit (PAC 3200)


.

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-33

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

33

DN02-S09011-E-XK-1005-33

+E05

Sheets:

49

<1>

IO202

/08.5

I1

A4

/08.6

A5

/08.6

A6

/08.6

A7

/08.6

A8

/06.2
/06.2
/06.2

B10 /1 2.5

BO 1.1

B9

A2

/08.5

/06.2

A1
A3

/06.2

<>

No. / Text

Siprotec 5 7SJ85

module 1 (IO202)

Siprotec 5 7SJ85

module 2 (PS201)

-F21.2

/08.5

/06.2

PS201

-F21.1
/08.5

6
<2>

F
I2

BO 1.3

B1

BO 1.5

B2

E
communication port

=
-

D-sub 9 Time

synchronization

B11 /1 2.6

/25.1

B1

B13 /1 2.6

/25.1

B2

B12

BO 2.1

C1

B14

BI 2.2

C4

B13

BI 2.3

C6

B11

U2

B6

B8

BO 2.2

B5

BO 1.6

B5

B7

C8

B4

B9

Life contact

C10

U3

B3

C3

B3

B4

BI 2.1

C2

BO 1.4

U1

Optical IEC61 850

=
+

B14 /1 2.6

I4

/1 2.5

B12 /1 2.6

BO 1.2

I3

Power
Supply

B10

C7

B6

B7

U4

B8

/20.2

C13

/20.2

D1

/20.2

C14

/20.2

D2

/20.3

D3

1 )

1 )

BI 1.1

BI 1 .2

1 )

BI 1.3

/20.3

D5

/20.4

D4

/20.4

D6

/20.4

D7

/20.4

D9

/20.5

D8

/20.5

D10

/20.6

D11

/20.6

D13

/20.6

D12

/20.6

D14

1)

1 )

1 )

BI 1.4

BI 1 .5

BI 1.6

1 )

BI 1 .7

1 )

1 ) USE THESE TERMINALS TO

ROOT THE BINARY INPUTS

F : Fast Switch

BI 1.8

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

DETNORSKE
02L

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Date:

P.O.Number

80EH0500

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Siprotec module 1 and 2

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-34

Installation: Ivar Aasen Field

Development Project - PDQ Platform

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

34

DN02-S09011-E-XK-1005-34

+E05

Sheets:

49

IO211

A1
A2

/05.6

A3

/22.2

U1

U2

A4

/05.6

A5

/05.6

A6

U3

U4

A8
/05.4

A11

/05.4

A12

/05.4

A13

/05.4

A14

C1

/05.4

C2

U6

C13

/21 .2

C14

/21 .2

D2

1)

1)

BI 3.1

BI 3.2

1)

/21 .3

D3

/21 .3

D5

/21 .4

D4

/21 .4

D6

/21 .4

D7

BI 3.4

/21 .4

D9

/21 .5

D8

/21 .5

D10
D11

/21 .6

D13

/21 .6

D12

/21 .6

D14

BI 3.3

1)

1)

/21 .6

A5

/22.3

A7

1)

BI 3.5

BI 3.6

1)

BI 3.7
1)

BI 3.8

1)

BI 4.1

BO 4.1

<>

No. / Text

Siprotec 5 7SJ85

module 3 (IO211)

Siprotec 5 7SJ85

module 4 (IO207)

1 )

BI 4.2

BO 4.2

BI 4.3

BO 4.3

B12 /1 5.5
B11 /1 5.5
B13 /1 5.5

1)

1)

C2

/1 6.4

C1

/1 6.4

C4

/1 6.4

A6

/22.6

A8

C3

/1 6.4

A9

C6

/1 6.5

C5

/1 6.5

C8

/1 6.6

C7

/1 6.6

BI 4.4

1 )

/23.1

A11

/23.2

A10

A12

1 )

BI 4.5

BI 4.6

BO 4.4

BO 4.5

BO 4.6

1 )

A13

BI 4.7

BO 4.7

C11 /1 7.5

1)

/23.3

B2

/23.4

B3

/23.4

B5

/23.4

B4

/23.4

B6

/24.1

B7

/24.1

B9

1 )

1 )

BI 4.8

C12 /1 7.5

B1
A14

C14 /1 7.5

BO 4.8

C13 /1 7.5

BI 4.9

BI 4.10

1)

BI 4.11

1 )

/24.2

B8

/24.2

B10

/24.3

D5

/24.3

D7

/24.5

D6

/24.5

D8

/24.6

D9

/24.6

D11

/24.7

D10

/24.7

D12

1 )

1 )

BI 4.12

BI 4.13

BI 4.14

1 )

BI 4.15

1 )

BI 4.16

1) USE THESE TERMINALS TO


ROOT THE BINARY INPUTS

1) USE THESE TERMINALS TO

ROOT THE BINARY INPUTS

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Siprotec module 3 and 4

StWe

02L

B14 /1 5.5

/22.6

/23.3
U8

A4

/22.3

/23.3

C4

D1

A2

/23.2

U7

C3

/21 .2

/22.2

/23.3

/05.4

/21 .2

A3

/23.1
U5

A1

/22.2
/22.2

A7

-F21.4

/05.6
/05.6

IO207

-F21.3
/05.6

6
<2>

<1>

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-35

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

35

DN02-S09011-E-XK-1005-35

+E05

Sheets:

49

-F21.5
/25.3

A1
A3

/25.3

A2
A4

/25.4

A5

/25.4

A7

/25.5

A6

/25.5

A8

/25.5

A9

/25.5

A11

/25.7

A10

/25.7

<>

No. / Text

Siprotec 5 7SJ85

module 5 (IO207)

Siprotec 5 7SJ85

module 6 (IO207)

-F21 .6

/25.3
/25.3

IO207

IO207

6
<2>

<1>

A12

/26.1

A13

/26.1

B1

/26.2

A14

/26.2

B2

/26.3

B3

/26.3

B5

/26.4

B4

/26.4

B6

/26.5

B7

/26.5

B9

/26.6

B8

/26.6

B10

/27.2

D5

/27.2

D7

/27.3

D6

/27.3

D8

/27.4

D9

/27.4

D11

/27.5

D10

/27.5

D12

1 )

BI 5.1

1 )

BI 5.2

B12 /1 8.4

BO 5.1

BO 5.2

BO 5.4

BI 5.4

BI 5.5

1)

BI 5.6

BO 5.5

BO 5.6

BO 5.7

/1 4.3

1)

BI 5.9

1)

BI 5.10

BI 6.3

BO 6.3

B11
B14

B13

A4

1 )

/1 4.6

A5

/1 8.5

/1 4.6

A7

C2

/1 8.6

/1 4.6

A6

C3

/1 8.6

/1 4.6

A8

C4
BI 6.4

BO 6.4

1 )

BI 6.5

BO 6.5

1 )

BI 6.6

BO 6.6

BI 6.7

BO 6.7

Note 1

C3

C6

A9

C5

A11

C8

A10

C5

C8

C7

A12

1 )

A13

C12

C11

B1
1 )

A14

C13

Note 1

C1

1 )

C4

C14
BO 5.8

BI 5.8

BO 6.2

/1 8.5

C11

1)

BI 6.2

A2

C12
BI 5.7

1 )

/14.3

C7

1)

BO 6.1

B14 /1 8.4

C6
1)

BI 6.1

A3

C1

1)

1 )

/1 4.2

C2
BO 5.3

B12

A1

B11 /1 8.4
B13 /1 8.4

1 )

BI 5.3

/1 4.2

BO 6.8

C13

B2
B3

1 )

C14

BI 6.8

BI 6.9

B5

B4

1 )

BI 6.1 0

B6

1 )

1)

B7

BI 5.11

BI 6.11

B9
1 )

1)

B8

BI 5.12

BI 6.12

B10

1)

BI 5.13

1 )

BI 5.14

D5

1 )

BI 6.13

D7

D6

1 )

BI 6.1 4

D8

1 )

1)

D9

BI 5.15

BI 6.15

1)

D10

1)

BI 5.16

BI 6.1 6

D12
1) USE THESE TERMINALS TO
ROOT THE BINARY INPUTS

Acceptance Code:

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

StWe

DETNORSKE
02L

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Siprotec module 5 and 6

Note 1

BO 6.3 mapped as test

pickup output

BO 6.4 mapped as test

trip output

D11

1) USE THESE TERMINALS TO


ROOT THE BINARY INPUTS

04L

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-36

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

36

DN02-S09011-E-XK-1005-36

+E05

Sheets:

49

/1 9.1 Heater
230 VAC

/1 9.2 Heater
230 VAC

X07:4

X07:5

Tripping coil 2
110 VDC L+
X07:22

/1 9.1 Heater
230 VAC

/1 2.6 Tripping coil 2


110 VDC L+
X07:28

X07:3

/1 2.7 Tripping coil 2


110 VDC L+
X07:30

244

243

53

233

54

234

224

A2

-F1

A1

A1

-KK4

-EB3

-EB2

-EB1

73
74

63

223

222

DC/AC

64

221

-M1

-BG1

A2

-KK3

A2

14

I>

83

43
44

84
X07:29

X06:27

-K1 0

X06:29

-K10

-K7

X06:4

21 71

-K7

X07:6

72 62

-K7

A1

13

61

-K10

22

Circuit breaker Q0 part 1


Type:

/1 2.1 DC motor
110 VDC L+

Tripping coil 1
110 VDC L+
X06:21

-QA9

A1

41

-BG|
103

-BG1

-QA9

-K7

Circuit breaker Q0

overview diagram

Part 1

I>

A2

-KK1

X06:3

/1 2.5 Tripping coil 1


110 VDC L+
X06:28
84
83

101
-BG1
1 02

-BG1

-F1

-BG1

104

52
42

DWG No: E50115-A0000-S014 (11-06-2013)

-BG1
94

-BG1

No. / Text

-BG1

93

22

14

-BG1

<>

/1 2.5 Tripping coil 1


110 VDC L+
X06:30

extended anti
pumping function
X06:20

13
-K7

51

61

-BG16
64

-BG1

21

63

62

X06:26

-Q0_1

53

+80EH0500+E05

54

Anti pumping
device 1

/1 2.6 Closing coil


110 VDCl L+

<1>

04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

/1 9.1

DC motor
L-

1
Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Circiut breaker Q0

StWe

02L

Acceptance Code:

Drawing Title:

Supplier

HFO

/1 2.2

Tripping
/1 2.6
coil 2 L-

Closing
coil L-

/1 2.6

Tripping
/1 2.5
coil 1 L-

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-37

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

37

DN02-S09011-E-XK-1005-37

+E05

Sheets:

49

Motor running time


supervision

/22.2 Motor protection

General
lockout SF6

<>

No. / Text

Circuit breaker Q0

overview diagram

Part 2

X06:14

X06:15

/1 2.4
X07:13

X07:12

X06:23

/1 2.3

/1 2.4

Operation cycle
counter

Motor running
time supervision
/1 2.3

X06:1

-Q0_2

X06:22

+80EH0500+E05

/1 2.3

General
lockout SF6

Control Voltage
110 VDC L+

<1>

Spare

Loss of SF6

-X31

5
-BP1

31

11

25

32

33

12

13

28

-BP1

-WG1

22

62

26

-K67

-F1

-K1 0
214

12

21

61

213

11

22

23

21

-WG1

-WG1

-WG1

-K67

-X31

18

16

-X31

A1

X06:11

/22.3

X06:10
/22.2

/22.2

X06:12

X06:16

A2

-K67

60 s

Control
voltage /1 2.4
110 VDC L-

-QA9

A2

-K10

A1

15

-X31

A1

Circuit breaker Q0 part 2


Type:

-BG1

-BG16

A2

-WG1

X06:2

DGW No: E50115-A000-S014 (11-06-2013)

-WG1

-BP1

-X31

-X31

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram

Circuit breaker Q0

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-38

+E05

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

38

DN02-S09011-E-XK-1005-38

Sheets:

49

Auto reclosure
interlock

<>

No. / Text

Circuit breaker Q0

overview diagram

Part 3

X06:17

/21 .6 General
loclout SF6

-Q0_3

X07:15

+80EH0500+E05

/21 .6 On-spring
unloaded

X07:10

<1>

-BG16

-K10

54

62

72

-K1 0

53

61

71

21

81
-K10

22

33

-BG16

34

-BG16
82

DGW No: E50115-A000-S014 (11-06-2013)

X06:19

X06:18

X07:16

/21 .6

/21 .6

X07:11

Circuit breaker Q0 part 3


Type:

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Circuit breaker Q0

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-39

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

39

DN02-S09011-E-XK-1005-39

+E05

Sheets:

49

<1>

<>

A
Circuit breaker on

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

Circuit breaker off

Circuit breaker on

X06:43

X06:45

X07:39

X07:41

X07:43

X07:45

X07:31

X07:33

X07:35

X07:37

X06:31

X06:33

X06:35

X06:37

X06:24

121

123

131

133

141

143

151

153

161

163

171

173

181

183

19

/1 1 .1

/28.3

Circuit breaker off

Circuit breaker on

Circuit breaker off


/28.3

Circuit breaker on
X06:41
113

/20.2

X06:39

114

122

124

132

134

142

144

152

154

162

164

172

174

182

184

10

X06:42

X06:44

X06:46

X07:40

X07:42

X07:44

X07:46

X07:32

X07:34

X07:36

X07:38

X06:32

X06:34

X06:36

X06:38

X06:25

-BG1

112

Circuit breaker Q0

overview diagram

auxilliary switches

X06:40

Q0 Circuit breaker aux. switches

-Q0_4

111

+80EH0500+E05

/20.2

Circuit breaker off

No. / Text

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Status switches
Circuit breaker Q0

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-40

+E05

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

40

DN02-S09011-E-XK-1005-40

Sheets:

49

/1 9.3 Heater
230 VAC

/22.4 Hand crank


cover open
X1:40

61

61
62

-QA2

21
22

-EB1

-M1

13

-QA2

A1

A1/RD

22
A1

-QA1

-BG23

-EB2

14

73

/22.4

/1 9.3

X1:2

X1:6
DC motor L- /1 5.3

X1:41

74

-QA2

74

43

X1:4

83

83
-QA1

/1 5.5

-QA1

73

1u
44

44
43

-QA2

Control
voltage L-

X1:31
Disconnector /1 5.5
on/off L-

84

84
-QA2

-BG22

-QA1

A2/BK

A2

1o

A2

DC

As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr

Acceptance Code:

HFO

Drawing Title:

Supplier

HFO

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Disconnector Q1

StWe

02L

Disconnector Q1

overview diagram

22

21

21
-QA1

-QA2

As Built

Description

13

13

53

-QA1

DETNORSKE

Issue

No. / Text

03L

<>

-BG23

04L

14

X1:5
14

27

X1:1

/1 5.3 DC motor
110 VDC L+

/1 5.5 Disconnector off

54
53
DGW No: E50115-A0000-S024 (11-06-2013)
Disconnector Switch Q1
Type:

-QA2

-QA2

-QA1

-QA1

-BG1
2

16

-BG26

28

-BG25
2

-BG1

15

X1:3

X1:30

-Q1

54

+80EH0500+E05

4
<1>

X1:32

/1 5.6 Control Voltage


110 VDC L+

/1 5.5 Disconnector on

62

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-41

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

41

DN02-S09011-E-XK-1005-41

+E05

Sheets:

49

<1>

<>

Disconnector on
make before break

Disconnector off
make before break

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

X1:7

X1:46

X1:10

X1:12

X1:14

X1:16

X1:18

X1:20

X1:22

X1:24

X1:26

X1:28

X1:36

X1:38

X1:42

X1:44

41

43

51

53

61

63

71

73

81

83

91

93

101

103

135

147

/28.5

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector Q1

overview diagram

auxilliary switches

-BG1
44

52

54

62

64

72

74

82

84

92

94

102

104

136

148

X1:9

X1:11

X1:13

X1:15

X1:17

X1:19

X1:21

X1:23

X1:25

X1:27

X1:29

X1:37

X1:39

X1:43

X1:45

42

X1:8

Q1 Disconnector aux. switches

-Q1 _1

/28.4

/20.3

+80EH0500+E05

Disconnector on

/20.4

Disconnector off

No. / Text

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Status switches
Disconnector Q1

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-42

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

42

DN02-S09011-E-XK-1005-42

+E05

Sheets:

49

Control Voltage
110 VDC L+

Hand crank
cover open

<>

/22.4

Heater
230 VAC

DC motor
110VDC L+
/1 6.2

/1 9.4

/1 6.4

Earthing
switch on

Disconnector
off

<1>

/1 6.6

/1 6.5

/1 6.4

Earthing
switch off

Disconnector
on

/1 6.6

No. / Text

3-position switch QZ2

overview diagram

As Built

13
62

22

-EB1

13

-M1

A1/RD
-QA2

A1

A1

-QA1

-BG23

-EB2

EsFr

EsFr
HFO

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Made by

Chc. by

Wood Group

Mustang

Appr. by

14

83

/22.4

/1 9.4

X1:2

X1:41

74

DC motor L- /1 6.2

SMOE

1
Tag no.

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
3-position switch QZ2

StWe

Acceptance Code:

Drawing Title:

Supplier

HFO

1 9.1 1 .1 4

Date

73

83
X1:6

X2:31
/1 6.5
Earthing
switch
on/off L-

X1:4
/1 6.6
DSF

-QA2

74

43

-QA1

Contro
voltage L-

1 7.03.1 5

-QA1

73

44

44
43

-QA2

05.05.1 5

84

84
-QA2

-BG22

-QA1

A2/BK

A2

1o

A2

DC

As Built

61

61
62
21

32

21

21
22

22

02L

Description

-QA2

DETNORSKE

Issue

X1:40

14

14
13

16
31

27

53

28

-QA1

1u
03L

As Built

X1:1

X1:5

X2:30
15

1
-BG1

-QA1

-QA2

Disconnector /1 6.4
on/off L04L

-QA2

-QA1

-BG23

X1:31

3-Position Switch QZ2


Type:

-QA2
53

28

32
DWG No: E50115-A0000-S055 (21-01-2013)

54

27

54

16
31

-QA1

-BG2

-BG2

-BG26
2

-BG25

-BG1

X1:32

X1:3
1

15

-QZ2

X2:32

X1:30

+80EH0500+E05

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51 PO-041 93.21 0-K-1 05-43

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

43

DN02-S09011-E-XK-1005-43

+E05

Sheets:

49

F
04L

03L

Issue
Description

1
44

52

54

62

64

72

74

82

84

92

94

102

104

136

148

X2:11

X2:13

X2:15

X2:17

X2:19

X2:21

X2:23

X2:25

X2:27

X2:29

X2:37

X2:39

X2:43

X2:45

X2:46

X2:10

X2:12

X2:14

X2:16

X2:18

X2:20

X2:22

X2:24

X2:26

X2:28

X2:36

X2:38

X2:42

X2:44

43

51

53

61

63

71

73

81

83

91

93

101

103

135

147

-QZ2_2

As Built

As Built
/20.6

/20.6

+80EH0500+E05

X2:9

X2:7

05.05.1 5

1 7.03.1 5

Date

2
DSF

EsFr

Made by

EsFr

HFO

Chc. by

02L
As Built
1 9.1 1 .1 4
EsFr
HFO
StWe

01E
Issued for review
01 .07.1 4
EsFr
HFO
StWe

HFO

Supplier

StWe

DETNORSKE

SMOE

Wood Group

Mustang

Appr. by

4
5

102

104

136

148

X1:37

X1:39

X1:43

X1:45

147

135

103

101

93

91

83

81

73

71

63

61

53

51

X1:44

X1:42

X1:38

X1:36

X1:28

X1:26

X1:24

X1:22

X1:20

X1:18

X1:16

X1:14

X1:12

X1:10

X1:46

Disconnector on

Disconnector off

Disconnector on

/20.5

/28.5

/28.6

Disconnector on
make before break

Disconnector off
make before break

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector off

/20.4

Earthing switch on
make before break

Earthing switch off


make before break

Earthing switch on

94

X1:29

74

X1:21

92

72

X1:19

X1:27

64

X1:17

84

62

X1:15

X1:25

54

X1:13

82

52

X1:11

43

X1:7

Earthing switch off

Earthing switch on

Earthing switch off

X1:23

44

X1:9

41

Earthing switch on

Earthing switch off

Earthing switch on

42

X1:8

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

-QZ2_1

41

+80EH0500+E05

42

B
QZ2 Disconnector auxiliary switches

X2:8

QZ2 Earthing switch aux. switches

1
<1>

Drawing Title:

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Status switches
3-position switch QZ2

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Tag no.

80EH0500

<>

Area:
Scale

Siemens Dwg. No.:

M120
NA
51PO-04193.210-K-105-44

System:
DWG Size Drawing No.:
Rev:
Sheet:

80
A3

04L
44

DN02-S09011-E-XK-1005-44

P.O.Number

S0901 1

No. / Text

1
3-position switch QZ2

disconnector auxilliary

switches

2
3-position switch QZ2

earhing switch auxilliary

switches

<2>

Acceptance Code:

David Stone

Date:

+E05

Sheets:

49

-BG1

-BG2

28/05/15

Signature:

=80EC0505

Control Voltage
110 VDC L+

Hand crank
cover open

<>

/22.5

/1 9.5

Heater
230 VAC

DC motor
110VDC L+

/18.6

/1 8.4

Earthing
switch on

Disconnector
off

<1>

/1 8.6

/18.5

/18.4

Earthing
switch off

Disconnector
on

/1 8.2

No. / Text

3-position switch QZ9

overview diagram

13
61

61

62

62
21

32

22

22

-BG23

-EB2

EsFr

EsFr
HFO

As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Made by

Date

Chc. by

SMOE

X1:41

Drawing Title:

Tag no.

Wood Group

Mustang

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram

3-position switch QZ9

Appr. by

/22.5

X1 :2

StWe

02L

Acceptance Code:

Supplier

HFO

14

83
73
74

/1 9.5

/1 8.2
DC motor L-

X1:6

X2:31
/1 8.5
Earthing
switch
on/off L-

X1:4
/1 8.6
Contro
voltage L1 7.03.1 5

DSF

-QA2

74

43

-QA1

05.05.1 5

84

84
73

-QA2
43

-QA1

83

1u
44

44
-QA1

A2/BK

A2

A2
1o

-QA2

-BG22

As Built

-EB1

13

-M1

A1/RD
A1

-QA2

DC

As Built

Description

-QA2

DETNORSKE

Issue

X1:40

14

14
13

16
31

27

53

28

-QA1

21

21
22
A1

-QA1

Disconnector /1 8.4
on/off L03L

X1:1

X1:5

X2:30
15

1
-BG1

-QA1

-QA2

X1:31

3-Position Switch QZ2


Type:
04L

-QA2

-QA1

-BG23

-QA2
53

28

32
DWG No: E50115-A0000-S055 (21-01-2013)

54

27

54

16
31

-QA1

-BG2

-BG2

-BG26
2

-BG25

-BG1

X1:32

X1:3
1

15

-QZ9

X2:32

X1:30

+80EH0500+E05

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-45

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

45

DN02-S09011-E-XK-1005-45

+E05

Sheets:

49

F
QZ2 Earthing switch aux. switches

04L

03L

Issue
Description

1
X2:10

X2:12

X2:14

X2:16

X2:18

X2:22

X2:24

X2:28

X2:36

X2:38

X2:42

X2:44

51

53

61

63

71

73

81

83

91

93

101

103

135

147

52

54

62

64

72

74

82

84

92

94

102

104

136

148

X2:11

As Built

As Built
X2:13

X2:15

05.05.1 5

1 7.03.1 5

Date

2
DSF

EsFr

Made by

X2:17

EsFr

HFO

Chc. by

X2:19

02L
As Built
1 9.1 1 .1 4
EsFr
HFO
StWe

01E
Issued for review
01 .07.1 4
EsFr
HFO
StWe
X2:21

3
X2:23

HFO

X2:25

X2:27

Supplier

StWe

DETNORSKE

SMOE

Wood Group

Mustang

Appr. by

4
X2:29

X2:37

X2:39

X2:43

X2:45

X2:26

102

104

136

148

X1:37

X1:39

X1:43

X1:45

147

135

103

101

93

91

83

81

73

71

63

61

53

51

X1:44

X1:42

X1:38

X1:36

X1:28

X1:26

X1:24

X1:22

X1:20

X1:18

X1:16

X1:14

X1:12

X1:10

X1:46

Disconnector on

/21 .2

Disconnector on
make before break

Disconnector off
make before break

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector on

Disconnector off

Disconnector off

/21 .2

Earthing switch on
make before break

Earthing switch off


make before break

Earthing switch on

94

X1:29

74

X1:21

92

72

X1:19

X1:27

64

X1:17

84

62

X1:15

X1:25

54

X1:13

82

52

X1:11

43

X1:7

Earthing switch off

Earthing switch on

Earthing switch off

X1:23

44

X1:9

41

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

/21 .4

42

X1:8

X2:20

X2:46

43

-BG2

44

Earthing switch off

-QZ9_2

X2:9

D
/21 .3

+80EH0500+E05

X2:7

-QZ9_1

41

+80EH0500+E05

42

X2:8

B
QZ2 Disconnector auxiliary switches

1
<1>

Drawing Title:

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Status switches
3-position switch QZ9

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Tag no.

80EH0500

<>

Area:
Scale

Siemens Dwg. No.:

M120
NA
51PO-04193.210-K-105-46

System:
DWG Size Drawing No.:
Rev:
Sheet:

80
A3

04L
46

DN02-S09011-E-XK-1005-46

P.O.Number

S0901 1

No. / Text

1
3-position switch QZ2

disconnector auxilliary

switches

2
3-position switch QZ2

earhing switch auxilliary

switches

<2>

Acceptance Code:

David Stone

Date:

+E05

Sheets:

49

-BG1

Signature:

28/05/15

=80EC0505

<>

/22.6 Hand crank


cover open

/1 9.7 Heater

/1 7.3 DC motor L+

/1 7.6 Control
Voltage L+

/1 7.5 Command on

/1 7.5 Command off

<1>

No. / Text

Earthing switch Q8

overview diagram

14

13

13

61

61

62

62

2o
2u

-EB1

-BG26

-M1

21

-QA2

A1

-QA1

A1

A1

-BG25

X1:40

14

X1:1

X1:5

X1:32
53
22

22

-QA2

-BG23

-BG22

-EB2

22

83

73

/22.6

/19.7

X1:2

X1:6
DC motor L- /1 7.3

X1:41

74

-QA2

74

43

X1:4

73

14
44

44
43

-QA1

-QA1

-QA2

Control
/1 7.5
Voltage L-

Command L- /1 7.5

84

84
-QA2
83

-BG23

-QA1

A2

A2

13

A2

DC

X1:31

-QA1

-QA1

-QA2

DGW No: E50115-A0000-S044 (21-01-2013)


High speed earthing switch Q8
Type:

-QA2

21

21

-QA1

-QA2
53

-QA1

54

54

-Q8

X1:3

X1:30

+80EH0500+E05

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

1 1 0 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Overview diagram
Earth switch Q8

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-47

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

47

DN02-S09011-E-XK-1005-47

+E05

Sheets:

49

<1>

<>

/21 .4

Earthing switch on
make before break

Earthing switch off


make before break

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch off

Earthing switch on

Earthing switch Q8

overview diagram

auxilliary switches

/21 .5

Earthing switch off

No. / Text

X1:44

X1:42

X1:38

X1:36

X1:28

X1:26

X1:24

X1:22

X1:20

X1:18

X1:16

X1:14

X1:12

X1:46

97

85

73

71

63

61

53

51

43

41

33

31

23

21

13

11

14

22

24

32

34

42

44

52

54

62

64

72

74

86

98

X1 :9

X1:11

X1:13

X1:15

X1:17

X1:19

X1:21

X1:23

X1:25

X1:27

X1:29

X1:37

X1:39

X1:43

X1:45

-BG1

12
/21 .4

/21 .5

X1:8

Q8 High speed earthing switch

X1:7

-Q8_1

X1:10

+80EH0500+E05

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Status switches
Earth switch Q8

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M120

NA

51PO-04193.210-K-105-48

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L

48

DN02-S09011-E-XK-1005-48

+E05

Sheets:

49

17

B
A

254

253

B
A

252

B
A

251

246

B
A

245

244

170

B
A

169

B
A

168

B
A

167

166

165

B
A

164

B
A

163

B
A

162

161

B
A

160

B
A

95

94

93

B
A

92

91

90

B
A

70

69

16

15

30

29

28

27

No. / Text

Spare terminals

26

<>

25

22

A
B

-X31

21

-X30

24

23

-X24

13

14

<1>

Acceptance Code:

1
04L

03L

As Built
As Built

05.05.1 5
1 7.03.1 5

DSF
EsFr

EsFr
HFO

Drawing Title:

Supplier

HFO

DETNORSKE
As Built

1 9.1 1 .1 4

EsFr

HFO

StWe

01 E

Issued for review

01 .07.1 4

EsFr

HFO

StWe

Issue

Description

Made by

Date

Chc. by

SMOE

Wood Group

Mustang

Appr. by

Installation: Ivar Aasen Field

Development Project - PDQ Platform

Date:

P.O.Number

80EH0500

110 KV SWBD - CIRCUIT/WIRING DIAGRAM, SPARE


.

Spare Terminals
.

StWe

02L

Tag no.

Signature:

David Stone

28/05/15

S0901 1

=80EC0505

Area:

Scale

Siemens Dwg. No.:

M1 20

NA

51PO-04193.210-K-105-49

System:

DWG Size Drawing No.:

Rev:

Sheet:

80

A3

04L