IID
(SLC 500 only)
There is no I/O to generate an interrupt, therefore this instruction has no effect.
IIE
(SLC 500 only)
There is no I/O to generate an interrupt, therefore this instruction has no effect.
IIM
(SLC 500 only)
There is no I/O to update, therefore this instruction has no effect.
IIN
There is no I/O image table to update in the software.
The instruction is not executed.
INT
(SLC 500 only)
There is no I/O to trigger an interrupt, therefore this instruction has no effect.
IOM
(SLC 500 only)
There is no I/O to update, therefore this instruction has no effect.
IOT
There is no I/O image table to update in the software.
The instruction is not executed.
MSG
Even though the software provides Data Highway Plus emulation and Channel 0 emulation,
the MSG instruction is not fully emulated.
When an MSG is "executed", the enable (.EN) bit is set during the first scan,
and the done (.DN) bit is set during the second scan.
If you wish, you may use debug files to emulate the data transfer.
1 of 3
7/21/2008 3:27 PM
http://rockwellautomation.custhelp.com/cgi-bin/rockwellautomation...
PID
The software does not attempt to execute the PID instruction or change any of the PID control bits or words.
REF
(SLC 500 only)
There is no I/O to refresh, therefore this instruction has no effect.
RPI
(SLC 500 only)
There is no I/O to generate an interrupt, therefore this instruction has no effect.
SVC
(SLC 500, MicroLogix 1200 and 1500)
There are no processor communications to service, therefore this instruction has no effect.
PTO
(MicroLogix 1200 and 1500 only)
There are no outputs. The instruction is not executed.
PWM
(MicroLogix 1200 and 1500 only)
There are no outputs. The instruction is not executed.
DLG
(MicroLogix 1500 only)
The data logging function is not emulated. The instruction is not executed.