Sie sind auf Seite 1von 2

Illustration 2

g00670066

Governor Actuator
(1) Governor Actuator
(2) Accelerator Cable

Illustration 3
Cable For The Governor Actuator
(2) Accelerator Cable
(3) Support
(4) Bellows
(5) Lever
(6) Decelerator Cable
(7) Nut
(8) Nut
(9) Bellows
(10) Locknut
(11) Locknut

g00670071

1. Turn the nut (8) and turn the locknut (10) of the accelerator cable (2) counterclockwise until
the nuts are separated.
2. Insert the threaded end "L" of the accelerator cable (2) and the decelerator cable (6) through
the hole in lever (5). Install a nut in order to hold the cable in position.
3. Insert the other threaded portion of the accelerator cable (2) into the notch of the support
(3).
4. Turn the lever (5) counterclockwise to the position of high idle stop.
5. Hold the lever (5) against the high idle stop. Turn the nut (8) clockwise until the slack is
removed from bellows (9). The nut (8) should be tightened for approximately two turns
more.
6. Tighten the locknut (10) against the support (3). Ensure that the nut (8) remains in position
on the threaded portion of the accelerator cable (2) while the locknut is being tightened
against the support (3).
7. Insert the other threaded portion of the decelerator cable (6) into the notch of the support
(3) .
8. Hold the lever (5) against the high idle stop and turn the nut (7) clockwise until the slack is
removed from the bellows (4). The nut (7) should be loosened for two turns more.
9. Tighten the locknut (11) against the support (3). Ensure that the nut (7) remains in position
while the nut (7) is tightened against the support (3) .
Note: Ensure that the governor lever is in contact with the high idle stop. Also, ensure that
the nut (8) is correctly tightened in order to ensure that the accelerator cable (2) has the
correct tension. The setting of the engine speed and an overload of the governor actuator
could result, if the cable is not correctly tightened.
Note: When the current governor actuator is being used the following conditions are
applicable:
a. The initial setting should always be performed when the governor actuator is being
supplied with power.
Note: If the current governor, that is being used, is a governor from spare parts, then
do not send electricity to the governor. The initial setting of the governor should
always be performed because the governor may have received electricity.

Calibration Of The Governor Actuator


Note: For more information, see the topic Testing And Adjusting, "Governor Actuator".
1. Start the engine. Perform the calibration procedure for the governor actuator.
2. Clear the error log, after the calibration procedure has been correctly performed.
Note: For more information, see Testing And Adjusting, "Error Log".