Beruflich Dokumente
Kultur Dokumente
Sr. N0.
Item Description
Units
Qty.
Lot
Sqft
1100
Sft
168
Sft
759
Nos
Nos
Sqft
440
Sqft
440
Sft
100
Sqft
175
Nos
DOORS
Providing and fixing Single Leaf 2 hour Fire Rated Metallic
Door with frame and Vision Panel size 200mm x 300mm
(1200mm x 2200mm)
2 Providing and fixing Single leaf LAMINATED FLUSH DOOR (9
mm laminate) with Door Frame and fittings, Door closure of
Dorma make with 200 high Handle.(900 x2200)
FALSE CEILING
Providing and fixing Non perforated GI Metal ceiling system
0.4mm thk with Microlook Edge in true horizontal level
suspended on XL 15mm locking grid system and having format
as 600 x 600 mm supported at minimum 1200 mm inervals,
made of hot dip galvanized steel section powder coated as per
manufacturers specification.
FLOORING
The access floor system shall provide a minimum finished floor
height of 450 mm from the existing floor level. The system
shall provide for suitable pedestal and understructure design to
withstand various static loads and rolling loads. The entire
Access floor system shall be be made from steel and
cementatious infilled Access Floor system.UDL of 1350kg /
sq.mt to be maintained for the raised floor tiles.
Providing and Fixing 2mm thk Antistatic and antiskid Vinyl
flooring.
PARTITION
Providing & laying of 200mm thick light weight block (Aerocon)
in cement mortar 1:5 (1cement: 4 coarse sand) including
raking out the joints complete as directed & specified.
FURNITURE WORKS
Nos
Sqft
40
Sqft
Nos
Sqft
1100
month
Nos
Sq Ft
2
40
sft.
646
1
2
3
5
7
8
1
TOTAL
MISCELLANEOUS
Providing & fixing - Floor Matts - 10mm thk as per requirement
Providing & fixing - Door Signages with vinyl cutting on acrylic
base.(size : 12"x3")
Providing and applying paint of approved make and pastel
shade to give an even shade over a primer coat as per
manufacturers recommendations after applying painting putty
to level and plumb and finishing with 2 coats of Plastic paint on
base coat of primer coat.
Housekeeping 2 person 1 industrial vaccum cleaner for 8
hours per day
Two Cup Tile Puller
Providing Step /ramp of 1200 mm Width and capable of
handling rack movement over the surface with matching
laimnation as raised floor with Vinyl Mat flooring and 3M
antiskid tape fixed horizontally at 1 feet distance each from
start to finish of the ramp . The structure should be of suitable
material and frame work of metallic nature if requested by
customer to handle heavey weight equipment
DISMANTLING AND REMOVAL
Demolishing and dismantling of existing partitions floors etc
SL.NO
QUANTITY
UNIT
1.1.2
40 kVA isolation transformer with K9 rating with enclosure and breaker at input with
busbars for input and out cable termination as per rating.
Nos
nos
1.1.16
1.2
1.2.1
A
1.2.2
A
1.3
A
B
C
2.1
A
B
2.2
Emergency Stop Button located remotely (near to the DC main door) to control the Two
Input supplies of Datacenter Main Panel and Two UPS sytems , wall mounted type with
suitable control wirings and accessories required. The Distance between the location of
Push button and the Datacenter main panel will be around 10 Meters and to UPS Room
is 25Mtrs..
FACTORY-BUILT MCB DISTRIBUTION BOARDS:
Supply, store, erection, testing and commissioning of MCB Distribution Boards of type IP43 Protection with Metal Door, wall-mounted (either surface or recessed type)as per
schematic drawings. The erection rates shall include fixing of DB on wall/Column
including supply of all fixing accessories, civil works etc., Space provision shall be made
for mounting ELCB in the incomer MCB. The rate shall be same for any combination of
outgoings (TP/SP).
HORIZONTAL TYPE. DOUBLE DOOR TPN DB :
6 Way TPN DB with seperator Incomer of approved make
SINGLE PHASE DB WITH DOUBLE DOOR :
8 Way DB of approved make
MCB, ELCB, ELMCB
Supply, store, erection, testing and commissioning of the following MCB,s, ELCB,s &
ELMCB,s
motor
6-32 AmpsofSP
MCBduty, C-curve charcterstics Din rail mounted to be fixed in the above
MCB Distribution Boards to suit any required combinations specified in the riser
6-32 Amps DP MCB
diagrams, With all the required accessories. C-curve has to be used for lighting and
6-32
MCB circuits and D-curve to be used for all UPS outgoing circuits.
utilityAmps
powerTPN
distribution
INDUSTRIAL TYPE SOCKETS AND PLUG TOPS
Supply, store, erection, testing and commissioning of factory made metal clad totally
enclosed with cast aluminium housing with industrial socket/interlocked combined rotary
switch and socket with scrapping earth connection and plug top. In case of interlocked
socket, the interlocking should ensure that the plug cannot be inserted or withdrawn while
the switch is in 'ON' position. (all switches & sockets shall be housed in painted MS
boxes). The erection rate shall include supply of angle iron frame work and fixing
accessories such as grip bolts/grouting/ welding to steel structures etc., All the MCBs
shall be of 'D' Curve specifications.
32A, 230V, 2P+E Plastic moulded industrial socket (female type), Overhead cable tray /
Raceways or surface mounted type. The pricing shall include to make the required
cutouts in the Raceways along with required accessories.
16A, 230V, 2P+E Plastic moulded industrial socket, Overhead cable tray / Raceways or
surface mounted type. The pricing shall include to make the required cutouts in the
Raceways along with required accessories.
MODULAR TYPE
Nos
Nos
Nos
14
8
6
Nos
Nos
Nos
20 Each
12 Each
A
B
3.0
3.1
A
C
D
E
F
4.0
4.1
A
B
C
D
5.0
6 Each
3 Each
250
Mtr
100
Mtr
100
Mtr
50
Mtr
100
Mtr
2
4
2
No.
No.
No.
Rate Only
No.
A
B
C
5.1
A
B
C
5.3
A
B
5.1
A
B
C
6.0
6.1
6.3
6.4
6.6
7.0
3 1/2 core, 240 sq mm Aluminum Armoured cable for input to Data Centre electrical panel
from TISS electrical panel.
3 1/2 core, 120 sq mm Aluminum Armoured cable for input to Data Centre electrical panel
from TISS electrical panel.
3 1/2 C x 10 Sq mm (Lighting and BMS)
1.1kV, Copper Conductor, PVC Insulated, Unarmoured, flexible LT Cable
1C X 25 Sqmm
3 1/2 C x 16 Sq mm (PAC Input)
3C x 6 Sqmm
Supplying and providing the end terminations with copper lugs for all the above cables
with Double compression brass cable glands, taping, crimping, gland and armour
earthing, etc. complete as required.
3 1/2 core, 240 sq mm Aluminum Armoured cable for input to Data Centre electrical panel
from TISS electrical panel.
3 1/2 core, 120 sq mm Aluminum Armoured cable for input to Data Centre electrical panel
from TISS electrical panel.
1.1kV, Copper Conductor, PVC Insulated, Unarmoured, flexible LT Cable
1C X 25 Sqmm
3 1/2 C x 16 Sqmm
3C x 6 Sqmm
EARTHING
Supply & installation of the following with clamps, inspection chambers, excavation, refill
with soil, charcoal, salt, compound as per technical specifications & IS standards.
Complete. The cost shall include excavation, bacfilling, compaction, construction of
chambers & all required civil works.
25 x 6 mm GI Strip
25 x 6 mm Cu. Strip with Green sleeves
6 sq mm Green copper cable conductor
600x600x3.15mm Copper plate electrode earth station.The chamber size shall be 450 x
450 mm with C.I. Cover plate. The identification number shall be provided both inside
and outside.
SUPPLY & INSTALLATION OF INDOOR LIGHTING FIXTURES
Supply, Erection, Testing & Commissioning of the following light fixtures complete with
Energy Efficient Electronic Ballast, Control gear and all the other standard accessories
along with High effiecient "T5" or Equivalent Tubes / Lamps.
20
Mtr
300
Mtr
40
Mtr
200
60
40
Mtr
Mtr
Mtr
No.
No
16
32
16
8
No
No
No
No
120
100
75
Mtrs
Mtrs
Mtrs
Nos
NOTE
1.1
A
B
8.0
8.1
8.2
8.3
A
B
A
8 Each
3 Each
0.75
M.T.
50
50
Mtr
Mtr
20
Mtr
8.4
L/S
S.N.
A
2
3
Qty
Unit
Nos
Nos
40
RMT
30
30
15
2
RMT
RMT
RMT
Nos
Nos
300
sq ft
Nos
2
2
Nos
Nos
Lot
Part #
UOM
SUVTR40KH5B5S
AR3100
AR3150
1
5
1.00
AP7552 / AP7551
AP7553
8
4
AR8165ABLK
AR8560
AR8561
AR8571
AR8162ABLK
AR8163ABLK
AR8172BLK
AR8173BLK
WASSEM5X8-3R-PX-10
WASSEM5X8-5R-PX-20
QWPRJ
QWPRJ
QWPRJ
1
2.00
5.00
1.00
7.00
7.00
1.00
1.00
1.00
1.00
1
1
1
1
2
3
4
C
1
2
3
4
5
6
7
8
Item description
UOM
Conventional Fire Alarm Systems
Supply and installation of Conventional 4 Zone Fire Alarm Panel , batteries
Nos.
etc. with 4 line auto dialer with recording message capacity .
Supply and installation of Conevntional photoelectric /Optical type smoke
Nos.
detectors with base.
Supply and installation of Manual call Points with base.
Nos.
Supply and installation of Conventional Electronic's Hooter cum Strobe
Nos.
Supply and installation of Response Indicator
Nos.
Fire Exit Signage boards with 3hrs battery backup
Nos.
Single side glow signage (100mm X 300mm)
Nos.
Supply and installation of 2 core 1.5Sq.mm Armoured FRLS cable.
Nos.
TOTAL
VESDA
Supply, Installing, Testing & Commissioning of the below as per
specifications:
Single zone Very early smoke detection panel (VLF 250)
Nos.
Power Supply Unit with Enclosure
Nos.
Aspiration Tubes, Capilary Tubes, Nozzles, accessories, etc.
Lot
25mm PVC Conduit
Mts.
TOTAL
FM-200 Gas Suppression System
FM-200 / HFC227 Gas Based Fire Suppression System - 42 Bar
System Only
80 Ltr.Seamless Cylinder CCOE Approved, complete with valve assembly.
Nos.
With Cylinder Strap.
HFC227 Gas (1,1,1,2,3,3,3 Hepta fluro propane) manufactured by GLCC
Nos.
or Dupont USA.
Electric Actuator
Nos.
Pneumatic Actuator
Nos.
Discharge Nozzles
Nos.
Master Cylinder Adapter Kit used to actuate the Slave Cylinder.
Nos.
Manual Actuator
Nos.
Flexible discharge Hose
Nos.
QTY
Makes
Ravel/Securico
System Sensor
4
2
5
1
1
150
System Sensor
Agni
STAR
STAR
STAR
Polycab/Technoflex
1
1
9
25
Xtralis
STAR
STAR
Precision/Ashoka
Kidde
50
Kidde
1
1
6
1
1
1
Kidde
Kidde
Kidde
Kidde
Kidde
Kidde
9
10
11
12
13
D
1
2
2
3
4
E
1
2
3
4
5
Cylinder Straps
Flexible Actuation Hose
Piping ASTM Grade A 106 Sch. 40 with fittings & supports
Manual Abort Station
Manual Release Station
TOTAL
Water leak detection system
Supply, Installing, Testing & Commissioning of the below as per
specifications:
2 Zone Water Leak detection Panel with LCDlLED display, power supply
and Water Leak detection Module resistant to oxidation and erosion having
a relay output for connection to the controller.
10mtrs. Water Leak Detection Sensing cable
15mtrs. Water Leak Detection Sensing cable
Sounder
Supply and surface laying of 2Cx 1.0
sq.mm Armoured Cable
TOTAL
Rodent Repellent System
Master Console capable of connecting to 12 Satellites complete with all
accessories as per specifications.
Satellite Units complete as per the specification
Rodent Cables
Bracket Stand
Supply & laying of 20mm PVC conduit
TOTAL
Nos.
Nos.
Nos.
Nos.
Nos.
2
1
1
1
1
Kidde
Kidde
STAR
Ravel
Ravel
Nos.
STAR
Nos.
Nos.
Nos.
1
1
1
STAR
STAR
STAR
Mtr
25
Polycab/Technoflex
Nos.
STAR
Nos.
RM
No.
No.
8
100
1
100
STAR
STAR
STAR
Polycab/Technoflex
SL No.
1
2
3
4
5
6
7
1
2
3
4
5
6
Description
Connectivity between Network rack & Server rack
at data center.
Cat 6A STP Patch cord, White, 2 Meter
10G, 24 Port Un loaded straight Jack Panel, 1U
Cat 6A AMP-TWIST 6S SL die-cast Jack without Dust
Cover
Cat 6A UTP Cable - Roll of 305 Mtrs, PVC
Cat 6A STP Patch cord, White, 2 Meter
Cat 6A STP Patch cord, White, 3Meter
2U Double sided Cable manager with Hinged door
system
Services
Laying of Cat 6A Cables
Termination of cables onto 24 port patch panels
Testing of cat 6A cables.
Integration of racks
Labelling & documentation of network ports
Project management charges
UOM
QTY
Nos
Nos
168
14
Nos
336
Nos
Nos
Nos
8
118
50
Nos
Mtrs
No's
No's
No's
Lot
Lot
2440
14
168
6
L/s
L/s