Sie sind auf Seite 1von 6

Project Details

Project Owner Name :


Project Name :
House or Apartment Block Name :

Edificio Vertice

Project Address Line 1 :

Edificio Vertice 237

Project Address Line 2 :


Project City :

Lima

Project Owner Email :

Project Province/State :

Lima

Project Owner Phone :

Project Postal Code :

Project Number :

Vertice 237

Jr. Punta Sal 237

Not Assigned

Lima 01

Project Country : Per


m

The master project floor area : 576.7

Location & Climate Data


Country :

Peru

City :

Lima

Income Category :

Upper Middle

Building Data

Area Details
Default

Type of Unit : Flats/Apartments

User Entry

Bedroom :

38.4

35 m

Average Unit Area :

128 m

Kitchen :

19.2

20 m

Bedrooms/Unit :

3 no.

Living/Dining :

48.6

45 m

Floors :

4 no.

Bathroom :

12.8

13 m

Units :

12 no.

Utility, Balcony, Service Shaft ** :

Occupancy (People/Unit) :

3 no.

Gross Internal Area :

128.0

External Wall Length m/Unit :

30.2

Window to Floor Ratio :

18%

15.0 m
128.0 m
30 m

**The Utility, Balcony, Service Shaft (m) field is equal to the


remaining space required to total the Gross Internal Area (m).

Building Systems
Air Conditioning : No
Space Heating : No

Created By : Julia Evans

File Number :

Modified By : Julia Evans

Project No. :

15112510002645
Not Assigned

EDGE Version :

1.0

Date Time : 25-Nov-2015 18:58:06

Key Assumptions for the Base Case


Default

User Entry

Fuel Used for Hot Water :

Electric Resistance

Electric Resistance

Fuel Used for Space Heating :

Electricity

Electricity

Cost of Electricity :

0.4

0.45 S/./kWh

Cost of Diesel Fuel :

1.8

1.75 S/./L

Jan :

22.5

23

Cost of LPG/Natural Gas :

1.9

1.83 S/./L

Feb :

23.2

23.5

Cost of Water :

3.2

3.3 S/./kL

Mar :

23.1

23

CO2 Emissions g/kWh of Electricity :

262.9

263 g/kWh

Apr :

20.9

21

Window to Wall Ratio :

0.3

May :

19.2

20

Solar Reflectivity for Paint - Wall :

0.7

Jun :

18.5

18

Solar Reflectivity for Paint - Roof :

0.3

Jul :

17.0

17.5

Hot Water Boiler Efficiency :

0.8

Aug :

16.6

17

Roof U Value :

2.2

W/m.k

Sep :

17.1

17.5

Wall U Value :

2.4

W/m.k

Oct :

17.8

18

Glass U Value :

5.7

W/m.k

Nov :

19.3

19.5

Glass SHGC :

0.8

Factor

Dec :

21.5

21

AC System Efficiency :

2.9

COP

Latitude :

12.1

Created By : Julia Evans

File Number :

Modified By : Julia Evans

Project No. :

15112510002645
Not Assigned

Monthly Average Outdoor


Temperature
(deg.C)
Default

EDGE Version :

User Entry

Deg

1.0

Date Time : 25-Nov-2015 18:58:06

Results
Final Energy Use :

444.4 kWh/Month/Unit Operational CO2 Savings :

Final Water Use :

15 kL/Month/Unit

0.4 tCO 2/Year

Embodied Energy Savings : 1,365.5 MJ

Base Case Utility Costs :

321 S/./Month/Unit

Utility Costs Reduction :

71 S/./Month/Unit

Energy Efficiency Measures 19.52% ENERGY SAVINGS

No

HME01 Reduced Window to Wall Ratio - WWR of 25%

WWR %
WFR

18%
50

No

HME02 Reflective Paint/Tiles for Roof - Solar Reflectivity (SR) of 70%

SR

No

HME03 Reflective Paint for External Walls - Solar Reflectivity (SR) of 70%

SR

No

HME04 External Shading Devices - Annual Average Shading Factor (AASF) of 0.51

Yes

HME05 Insulation of Roof - U Value of 0.44

[W/m K]

No

HME06 Insulation of External Walls - U Value of 0.46

[W/m K]

No

HME07 Low-E Coated Glass - U Value of 3 W/m K and SHGC of 0.45

[W/m K]

AASF

SHGC
No

HME08 Higher Performance Glass - U Value of 2 W/m K and SHGC of 0.28

[W/m K]
SHGC

No

HME09 Natural Ventilation

No

HME10 Ceiling Fans in all Habitable Rooms

Created By : Julia Evans

File Number :

Modified By : Julia Evans

Project No. :

15112510002645
Not Assigned

EDGE Version :

1.0

Date Time : 25-Nov-2015 18:58:06

No

HME11 Air Conditioning System - COP of 3.5

COP

No

HME12 High Efficiency Boiler for Space Heating - Efficiency of 0.008

% Eff.

No

HME13 High Efficiency Boiler for Hot Water - Efficiency of 0.9

% Eff.

No

HME14 Heat Pump for Hot Water - COP of 3

No

HME15 Energy Efficient Refrigerators and Clothes Washing Machines

Yes

HME16 Energy-Saving Light Bulbs - Internal Spaces

Yes

HME17 Energy-Saving Light Bulbs - Common Areas and External Spaces

No

HME18 Lighting Controls for Common Areas and Outdoors

No

HME19 Solar Hot Water Collectors - 50% of Hot Water Demand

COP

% Hot Water
Collector Area(m)/Unit

No

HME20 Solar Photovoltaics - 25% of Total Energy Demand

% of Annual Electricity Use


Capacity kWp/Unit

No

0.8

HME21 Smart Meters

Created By : Julia Evans

File Number :

Modified By : Julia Evans

Project No. :

15112510002645
Not Assigned

EDGE Version :

1.0

Date Time : 25-Nov-2015 18:58:06

Water Efficiency Measures

17.6%

WATER SAVINGS

Yes

HMW01 Low-Flow Showerheads - 8 lt./min

Lt./min

Yes

HMW02 Low-Flow Faucets for Kitchen Sinks -10 lt./min

Lt./min

10

Yes

HMW03 Low-Flow Faucets for Washbasins - 6 lt./min

Lt./min

No

HMW04 Dual Flush for Water Closets - 6 lt./first flush and 3 lt./second flush

1st - Lt./flush
2nd - Lt./flush

Yes

HMW05 Single Flush for Water Closets - 6 lt./flush

No

HMW06 Rainwater Harvesting System - 50% of Roof Area Used for Rainwater Collection

No

HMW07 Recycled Grey Water for Flushing

No

HMW08 Recycled Black Water for Flushing

Created By : Julia Evans

File Number :

Modified By : Julia Evans

Project No. :

Lt./flush

15112510002645
Not Assigned

% of Roof Area Used

EDGE Version :

1.0

Date Time : 25-Nov-2015 18:58:06

Materials Efficiency Measures 62.5% EMBODIED ENERGY SAVINGS Meets EDGE Materials Standard

HMM01

Floor Slabs

Concrete Filler Slab

mm

200

HMM02

Roof Construction

Concrete Filler Slab

mm

150

HMM03

External Walls

Medium Weight Hollow Concrete Blocks

mm

150

HMM04

Internal Walls

Medium Weight Hollow Concrete Blocks

mm

150

HMM05

Flooring

Laminated Wooden Flooring

HMM06

Window Frames

Aluminium

HMM07

Roof Insulation

None

HMM08

Wall Insulation

None

Created By : Julia Evans

File Number :

Modified By : Julia Evans

Project No. :

15112510002645
Not Assigned

EDGE Version :

1.0

Date Time : 25-Nov-2015 18:58:06