Sie sind auf Seite 1von 2

TruTec Scanning Services

Neutron Backscatter Study


Measure level and interfaces in vessels and storage tanks
Monitor fouling deposits
Identify plugs and vapor pockets in piping
Measure froth heights in tower downcomers
Measure liquid levels on tower distributors/chimney trays
Detect interface/emulsion band in separators
Identify liquid levels in reboilers/heat exchangers

Vapor

Foam

Vapor
Organic

Organic
Water
Deposition
Water

Deposition
Typical response

A TruTec Neutron Backscatter measurement is used to trouble-shoot or optimize on-line processes. It can measure liquid levels, vapor
pockets, fouling, or interfaces between different phases by detecting differences in hydrogen concentration. This system is an extremely
efficient method of verifying liquid levels in pressure vessels, determining froth heights in downcomers, identifying plugs in piping, or sludge
levels inside tanks.

TruTec Scanning Services

Neutron Measurement on a Polymer Line


A neutron source emits neutron particles which pass readily
through insulation and carbon steel to measure process

Do you have fouling or sludge material build-up in


your relief valve system or process piping?
Piping Measurements

material within a range of 4 - 6 inches. The neutron particles

The neutron

are moderated (scattered) by Hydrogen nuclei, and measured

measurement can

by a detector that adjoins the neutron source, illustrated in the

be used to quickly

figure shown below.

identify flow
restrictions in
piping, or vapor
pockets that may
be contributing to
pump problems. Several rubber and polymer plants require
routine neutron surveys of all their relief piping in the plant, to
assure that no dangerous deposits exist that would result in
undesirable back pressures or flow restrictions.
Neutron measurements are very complementary to our
TRU-SCAN technology results. Froth height or level information

Do you have problems with your tank inventory?


Tank and Pressure Vessel Measurements

provided by our neutron system can be invaluable for identifying


design problems or restricted liquid traffic due to downcomer
blockages. This system is light, compact and portable, therefore

The Neutron Backscatter system is frequently used to verify

its range of application is not limited by set-up requirements. If

level indication devices, detect fouling deposits on tank or

you would like to learn more or if you have a problem that

pressure vessel walls, and to inventory vessels where more than

appears to be suitable for investigation please contact a

one material is present.

Technical Advisor in your area. Additional information is


provided on our website at www.tracerco.com.

Corporate Headquarters:
4106 New West Dr.
Houston, TX 77507 USA
Tel 281 281 7761
Fax 281 291 7709
Toll Free 800 288 8970

Newark, DE 19702 USA


Tel 302 454 1109

West Valley City, UT 84119 USA


Tel 801 478 0736

Merrillville, IN 46410 USA


Tel 219 945 0400
Toll Free 877 994 0400

Edmonton, AB, T6E 6A6 CANADA


Tel 780 469 0055

Field Office Locations:

Baton Rouge, LA 70820 USA


Tel 225 761 0621

Corpus Christi, TX 78409 USA


Tel 361 242 4815

Concord, CA 94520 USA


Tel 925 687 0900

www.tracerco.com

Sarnia, ON, M7S 5C5 CANADA


Tel 519 332 6160

tracercotracerco.com

A Member of the Johnson Matthey Group


TRACERCO and TRACERCO Diagnostics
are trademarks of the Johnson Matthey
Group of companies.

XM0160/0/O/JM1058/968