PPH Catalog
Packaged Air Conditioning units
with Hermetic Compressor
3.0-53.0 T.R. @ 50 Hz
3.5-59.0 T.R. @ 60 Hz
R22
www.petra-eng.com
50/60 Hz Imperial
Abcde abcde
abcdefg
Petra Products
Equipment Description
Series
APX
APS
RWC
WPX
WPS
WRWC
HRWC
CPX
CPS
CRWC
Equipment Description
Fan Coil Units
Low Static Pressure Fan Coil
Medium Static Pressure Fan Coil
High-Wall Plastic Fan Coil
Stack Type Fan Coil
Air Side Control Fan Coil
Free Standing Decorative Units
Air Handlers:
Comfort Maker
Air Handling Unit (Modular Type)
Series
RAC
DC
PWC
RSU
ASC
FSW
CM
PAH
Exhaust Fan
Package Units With Hermetic (Reciprocating & Scroll Compressor)
Package Units With Semi-Hermetic (Reciprocating Compressor)
Water Source Unit
Self-Contained Wall Mount Air Cooled Package
Split Units
Ducted Split Unit (Low, Medium & High Capacity -Hermetic Compressor)
Ducted Split Unit (High Capacity-Semi Hermetic Compressor)
Ducted Split Unit (Centrifugal Condenser Fans Hermetic Comp.)
Mini Split Wall Type
Mini Split Universal Type (Floor & Ceiling)
Cassette Type Unit
Free Standing Units
Close Control Split Unit (Computer Room)
Air Cooled refrigeration Unit
Air Cooled refrigeration Unit (Cold Stores)
Unit Cooler
Unit Freezer
PPH
PPS
PWSP
PWM
DSP
DSPS
PECU
C/HPW
C/HPU
PCU
FSX
PASC
RFU
RCU
UC
UF
* For special cases where standard designs do not fulfill the customers requirements,
custom-made designs can be made available.
Smart Fan
Full Duty
PEXT
PEXS
Heaters
Unit Heater
Electric Heater
Duct Heater
Others
Dry Coolers
Package Unit With Natural Gas Heater
Heat Pump Application For All Dx Units
Note:
EMC certification applies to 50 Hz specifications only.
UL & ETL Marks applies on US & Canada markets' products
UH
EH
DH
Index
Main
Introduction
1
Model Number Nomenclature
1
Main Description
1
Specifications
2
Standard Features
3
Optional Features
3
Microprocessor Controller
5
Selection Procedure
6
Series Data
General Data 50 Hz
8
General Data 60 Hz
10
Model Layout-standard construction12
Model Layout-optional construction 16
Performance Tables 50 Hz
22
Performance Tables 60 Hz
25
Evaporator Coil & Filter Pressure
Drop Charts
28
Petra Fan Series
29
Electrical Information
Data Tables 50 Hz
34
Data Tables 60 Hz
35
Wiring Diagrams
36
Refrigeration Schematic Diagram
38
Introduction
PPH units are single packaged units which are factory assembled, tested and shipped fully charge complete with
compressor, evaporator and condenser coils, fans and controls. These packages are designed for outdoor
installation, and they used for cooling only or cooling and heat pump application (optional).
PPH units are ideal for residential, commercial and industrial applications and are available in nominal range 3.0 to
53.0 tons @ 50Hz and 3.5 to 59.0 tons @ 60Hz.
Quality design and construction make PETRA's air-cooled package units with hermetic compressors the preferred
choice for applications utilizing DX cooling systems. PETRA's PPH series is designed for flexible capacity
applications and easy installation and maintenance.
Easy Installation
PPH units are compact in design, supplied in a complete package ready for operation, with no extra controls or
additional items for installation. The PPH units have a single power point entry with simple connections. All units
are designed to ensure maximum compliance with European standards CE-Mark and EMC through TUV.
Quick start-up is assured once installation is complete, as each PPH unit is manufactured in an ISO 9001 listed
facility to guarantee quality. In addition, all units are tested at the factory to provide reliable start up.
Note:
For more technical details, please refer to the nearest Sales Office or to PETRA Factory.
Nomenclature
P
P
H
60
Petra
Packaged Air Conditioner
Hermetic Compressors
Unit Size (Nominal Capacity MBH)
Main Description
Quiet Operation
Specifications
Casing
Compressor
The compressor(s) used is hermetic refrigerant gas cooled,
with internal thermal protection . Starting is direct -on- line
with high efficiency and low sound levels, to match all other
Petra products' reliability and efficiency.
Models PPH 40 up to PPH 105 are with reciprocating type
compressors while models PPH 115 and higher are with
scroll compressors.
Filters
All Models are provided with 1.0 inch thick aluminum flat
filter (as standard features). Other filters are available upon
request.
Drain Pan
All units are provided with a drain pan having a drain
connection from one side. The drain pan is insulated on the
sides and underside to prevent condensation.
Insulation
All units are internally lined with 1.0 inch thick fiberglass
insulation for the coil and fan section (evaporator side only).
Standard Features
b- Through the external timer for Petra Mark III
controller.
5. Crank case heater for each compressor.
6. Control circuit breaker.
7. 220 volt as control voltage.
8. Microprocessor controller for model PPH 85 and above,
with the following main functions:
a- Compressor lead-lag operation to ensure longer
life for the compressors and equal running hours
between compressors.
b- External remote ON/OFF button for remote
operation of the unit using external ON/OFF
switch or connection to building management
system.
9. One power supply input.
10. High (manual reset) and low (automatic reset) pressure
safety switches (Capsule type; factory pre-set).
11. For models PPH 105 and above, voltage monitor
controller (phase failure relay) for monitoring the main
incoming power supply for the unit, which provides
protection from single phasing, under voltage, phasevoltage imbalance and phase- consequence.
A) Construction standard:
1. Easily accessible system components.
2. Ample space for easy access to power and control panels.
3. Heavy duty mounting chassis for the whole unit with
lifting lugs.
4. Rubber anti-vibration mounting for the compressors.
5. Weather proof, polyester-epoxy powder electrostatic paint
oven-baked finish for sheet metal and multi polyesterepoxy coating for base frame.
6. All units are shipped out from factory tested with safety
and control devices set against client requirement.
7. Variable pitch pulley for evaporator motor (for motors of
5.5 kW and less).
8. Single skin evaporator side with 1 inch thick fiberglass
insulation.
9. All suction lines are covered with rubber insulation, and
for further protection, the lines that extends in the
condenser side are wrapped-in cheese cloth and epoxy
painted with the same compressor color.
B) Electrical features:
C) Refrigeration features:
Optional Features
14. Economizer option with fresh, return and exhaust air
dampers with actuators.
15. Gas Heater.
A) Construction options:
1. Plastic mesh around condenser section perimeter.
2. Mixing box with manually operated fresh and return air
dampers.
3. Roof top arrangement (bottom air supply and return unit).
4. Roof curb mounting.
5. Bag filter.
6. Anti corrosion protection for coils fins (for copper /
aluminum coils only).
7. Copper/copper coils.
8. Hot water coil (built inside unit)
9. Synthetic fiber media for flat filter.
10. 2.0" or 4.0" thick flat filter or V-type filter.
11. Double skin evaporator side.
12. Different evaporator side insulation material.
13. 2.0" thick insulation for evaporator side only.
B) Electrical options:
C) Refrigeration options:
Selection Procedure
This example illustrates a step by step selection procedure to assist any user of this catalogue to select the appropriate
package unit to meet specific requirements.
Altitude (ft)
530 MBH
350 MBH
95 F
80 / 67 F
15,000 CFM
0.5 of Water
3000 Ft
Sea Level
1000
2000
3000
4000
5000
6000
7000
8000
Capacity
Correction
Factor
1
0.995
0.99
0.985
0.98
0.973
0.967
0.96
0.95
Using the correction factor table to correct capacity for altitude, the required capacity will be:
Corrected Capacity = Required Capacity / Correction Factor
= 530 / 0.985
= 538.1 MBH
Corrected Sensible Capacity = Required Sensible Capacity / Correction Factor
= 350/ 0.985
= 355.3 MBH
From the cooling capacity tables (Performance Tables on page 24, model PPH530 is the closest selection to the required
capacity. So, from the table:
Total Capacity = 542.5 MBH
Sensible Capacity = 361.9 MBH
Evaporator Fan Selection
1. Determine Evaporator Coil Face Velocity
From the general data tables on page 9, find the evaporator coil area ft2 .
Coil face velocity
=468.75 fpm
Now use the coil and filter charts on page 28, using face velocity of fpm to get the coil pressure drop and filter pressure drop
which are about 0.33 inch [H2O] and 0.125 inch [H2O] respectively.
Calculate total pressure drop
Total static pressure drop = External Static pressure drop+Evaporator Coil pressure drop+filter Pressure drop
= 0.5+ 0.33+0.125
= 0.955 Inch of [H2O]
Now from the general data table on page 9 find the evaporator fan model to be PETRA 9 unit, From the fan curves on pages
30 with air volume of (16000 cfm) find the following:A. Dynamic pressure drop [Velocity pressure] at 16000 cfm to be inch of [H2O]
B. Determine total fan pressure drop:
- Total Fan pressure drop
Now from the fan curve with 7500* cfm and 1.435 H2O we get the following:
1) Revolution / miniature impeller
2) Absorbed power
: 585 RPM
: 1.75 KW
*From the above data the following must be done to get the data for the double fans (this unit has 2 fans)
1) RPM should be multiplied by * 1.05, so
585 * 1.05 = 614 RPM (approximately)
2) The absorbed power should be multiplied by * 2.15, so
1.75 * 2.15 = 3.76 kW (approximately)
3) The motor kW can be obtained by adding power correction , (i.e 20%), so
3.76 * 1.20 = 4.512 kW
= 5.5 kW ( from the standard motors)
- Sound power level: from the general data tables on page 9, the sound pressure level at
10 ft=78.0 dB(A)
33 ft=72.0 dB(A)
*note:when the unit has two evaporator fans, the following should be done:
1) CFM should be divided by 2
2) RPM should be multiplied by * 1.05
3) The absorbed power should be multiplied by * 2.15
16
17
18
19
20
21
Petra 4
1.20
1.08
0.96
0.84
0.72
0.60
0.48
0.36
0.24
0.12
0
235 471 706 942 1177 1413 1648 1884 2119 2354 2590 2825
29
4.40
4.00
3.60
3.20
2.80
2.40
2.00
1.60
1.20
0.80
0.60
0.40
0.36
0.32
0.00
0.90
1.18
1.47
1.77
2.35
8.83
11.77
0.2
0.4
0.8
4.0
8.0
4.00
3.60
3.20
2.80
2.40
2.00
1.60
1.20
0.80
0.60
0.40
0.36
0.32
0.00
1.77
2.35
3.00
8.83
11.77
17.66
0.2
0.4
0.8
1.2
1.6 2.0
4.0
8.0
40.0
14.00
12.00
8.00
4.00
2.00
1.60
1.20
0.80
0.40
0.32
1.27
2.12
4.24
6.36
8.47 10.60
21.19
42.37
63.57
95.34
0.2
0.4
2.0
4.0
20.0
40.0
36
37
38
Quality Management System ISO 9001;2000 and Environmental Management System ISO
14001;1996 Certification applies to Jordan Office only
Copyright 2002 By Petra Engineering Industries Co.
Design & Layout Copyright 2002 By Petra Engineering Industries Co.
ALL MODELS SIZES AND DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE
Headquarters
P.O.Box 141351 Amman, 11814 JORDAN
Factory Tel (962 6) 4051055 Fax 4051228
Marketing Tel (962 6) 5531508 Fax 5531513
Local Sales Tel (962 6) 4051425 Fax 4051248
International Sales Tel (962 6) 4051050 Fax 4051087
North/South America Sales Tel (962 6) 4051425
Fax (In the US) (888) 5226610 - (877) 4723010
LOCAL BRANCHES
Amman: Tel (962 6) 5531508 Fax 5531509
Mecca Street: Tel/Fax (9626) 5850553
Marj Alhamam: Tel (962 6) 5716151 Fax 5712008
Irbid : Tel/Fax (962 2) 7252406
Aqaba : Tel (962 3) 2019189 Fax 2019728
e-mail:petrasho@go.com.jo
www.petra-eng.com
PP/PPH-R22-50-60 Hz-Imp/2002/rev.0