Sie sind auf Seite 1von 2

Technical Bulletin

PAGE: 1/2

Reissued: 21-Sep-11
Model: AP-C1

Date: 21-Jul-06

No.: RB222010e

RTB Reissue
The items in bold italics have been added.
Subject: Firmware Release History (Scanner)

Prepared by: H. Tamaki

From: 1st Overseas Tech Support Sec., 1st PQM Dept.


Classification:

Troubleshooting

Part information

Action required

Mechanical

Electrical

Service manual revision

Paper path

Transmit/receive

Retrofit information

Other ()

This RTB has been issued to announce the software release information for the Scanner.
Version
ap_1.25
ap_1.24
ap_1.23
ap_1.22
ap_1.21
1.57
ap_1.20
1.51.2

Program No.
B2215604H
B2215604G
B2215604F
B2215604E

Effective Date
September 2011 production
March 2010 production
January 2008 production
June 2007 production

B2215604D

October 2006 production

B2215604C

June 2006 production

Availability of RFU
Available
Available
Available
Available
Available
Available

Note: Definition of Availability of RFU via @Remote


Available The firmware can be updated via RFU or SD card.
Not available: The firmware can only be updated via SD card.

Version
ap_1.25

Symptom Corrected
Other changes:
Job Cancel + Mode Clear is carried out when card is taken out in the following
status:
- Reading originals
- Job cancel confirmation is displayed.
- During the job cancel (Jam, memory full)

Technical Bulletin

PAGE: 2/2

Reissued: 21-Sep-11
Model: AP-C1
Version
ap_1.24

Date: 21-Jul-06

No.: RB222010e

Symptom Corrected
Symptom corrected:
1. A scan configured to output a Multi-page TIFF might have actually output a PDF.
This only occurred if both of the following conditions were met:
- Scanner operation panel > Send Settings > Compression (Gray Scale/Full
Color) > OFF
- Scanner operation panel > Scan Settings > Scan Type > Auto Color Select
2.

Scan to NCP fails if all of the following conditions met:


- The destination is specified using the IP address.
- The Novell server and the device are in different subnets.
- The subnet routers filter SLP multicasts.
Note: Requires System firmware (version 1.70 or later) and Scanner firmware
(version ap_1.24 or later).
3.

ap_1.23

ap_1.22

Scan to NCP fails or takes long time to complete if the IPX protocol is used and
there are more than 2 Novell Directory Services (NDS) servers in the netwok
hierarchy.
Note: Requires System firmware (version 1.70 or later) and Scanner firmware
(version ap_1.24 or later).
Symptom corrected:
1. Scan to NCP problems. (TechMail#TS070022)
Note: Both System firmware (version 1.67 or later ) and Scanner firmware
(version 1.23 or later) need to be applied to fix this issue.
Symptom corrected:
1. The device or just the scanner application might stall when the device is awoken
from sleep mode. This only happened if both of the following conditions were met:
- User authentication was enabled.
- The SNTP polling interval setting was "Constant Intervals".
Other changes:
1. Supports the Catalan and Turkish languages.
For the details of this, please refer to RTB#RB222031 "Supports the Catalan and
Turkish languages".
Note: To support this feature, install all of the following firmware:
- System_Copy firmware ver 1.63 or later
- LCDC firmware ver 1.15 or later (Language firmware ver 0.77 or later)
- Printer firmware ver 1.06 or later
- Websys firmware ver 1.06.1 or later
- WebDocBox firmware ver 1.12 or later
- Scanner firmware ver 1.22 or later
- Fax firmware ver 01.03.00 or later
- FCU firmware ver 04.00.00 or later

ap_1.21
ap_1.20

Fixed: The device or just the scanner application will stall when the device is awoken
from sleep mode. This only affects devices that use an SNTP server.
1st Mass production