Sie sind auf Seite 1von 3

CT HB 602, HB 603

Data Sheet - N0036

Current transformer

Page 1/3
October 2003

Characteristics

Primary circuit of window type for standard cables or


conducting bars.
It allows any installation position around the primary
conducting bar.
Reduced size for installation space saving.
Available for secondary currents of 1 A or 5 A .
CT HB 603 double terminals make connection easier and allow
major safety when short-circuiting the secondary winding.

Application

Measuring of electric currents with major safety isolating the primary


power circuit from the secondary measuring circuit.

Technical Data (NBR 6856 )


Housing
Temperature class
Electrical
Connections
Polarity
identification
Fastening
Rated secondary
current
Working voltage
Rated frequency
Thermal factor
Test voltage
Thermal current
Dynamic current
Weight

plastic
B (max. 130C)
Primary circuit: passing cable or conducting
bar
Secondary circuit: terminals with lock and
screws
Primary circuit: P1 and P2
Secondary circuit: S1 and S2
Primary cable or bar (normal)
Loose delivered primary bar (optional)
1 A or 5 A
0,6kV (r.m.s.)
50/60 Hz
1,5 Irtd
4,0kV / min - 60 Hz
60 x Irtd / 1 s
150 x Irtd / 0,1 s
HB 602 0,35kg .
HB 603 0,4...0,6kg (according to the field).

Notes:
As a current transformer elevates the voltage, it must have the
secondary circuit always short-circuited before disconnecting the
measuring instrument.
Same indexes correspond to same polarities.
In delivery included accessories:
HB 602 - holder for fastening on cable or bar.
2 fastening supports for base.
HB 603 - 1 fastening support with screws for bar.
2 fastening supports for base.
In case of currents under 50 A, the primary conductor has to be
Winded through the window around the transformer with a
number of windings corresponding to the relation between the
measuring current and the primary current of the used transformer.
Example: Measuring current = 10 A
Primary current of the transformer =50 A
Number of windings of the conductor = 5 windings
( 1 winding = 1 passage of the primary conductor
through the window)

Specification text
Primary
Current

Code

(A)

Class/ Capacity (VA)


HB 602

HB 603

50

0050

3 C 2,5

60

0060

3 C 2,5

75

0075

3 C 2,5

100

0100

1,2 C 2,5

1,2 C 3,75

150

0150

0,6 C 3

0,6 C 2,5

200

0200

0,6 C 3

0,6 C 2,5

250

0250

0,6 C 3

0,6 C 3,75

300

0300

0,6 C 5

0,6 C 5,0

400

0400

0,6 C 5

0,6 C 5,0

500

0500

0,6 C 5

0,6 C 5,0

600

0600

0,6 C 5

0,6 C 7,5

800

0800

-----------

0,6 C 7,5

CT HB 602, HB 603
Current transformer

Dimensional Drawing
Dimension ( in mm)
CT 602

CT 603

Data Sheet - N0036


Page 2/3
October 2003

CT HB 602, HB 603

Data Sheet - N0036

Current transformer

Page 3/3
October 2003

Ordering information
Catalog number
Current Transformer

Type
HB 602, ring type, secondary/1A
HB 602, ring type, secondary/5A
HB 603, window type, secondary/1A
HB 603, window type, secondary/5A
Measuring range
Inform primary according specification of text.
Version
HB
Export

----

2
3
4
5
xxxx
H
E

Additional information
Normal

Example for solicitation:


Current transformer HB602, ring type 400/5A
Code: N003630400H1

ABB Ltda - ATLV/IE Electrical Instrumentation


Avenue Autonomistas, 1496 - 06020-902 - Osasco - SP
Phone: +55 11 3688-8320 / 8323 / 8347 - Fax: +55 11 3688-8322
instrumentacao@br.abb.com