Transducer ETM 50

Data Sheet - N00393/9

For alternating current or voltage

Page 1/4
July 2005

Caractersticas

Measuring of sinusoidal electric magnitudes.


Measuring RMS (Optional) of sinusoidal eletric magnitudes or not
sinusoidal
Linear measuring field.
Output signal with or without supressed zero
Galvanic isolation between input and output and auxiliary power
supply.
Reduced size for mounting space saving.
Case type housing for fastening on rail.

Application

Conversion of an alternating sinusoidal voltage or current into a


signal of direct current or voltage, which is independent on the load

Functioning

The transducer ETM 50 with alternating sinusoidal voltage or


current input is a fully electronic instrument, which work on the
principle of rectification.

Technical data (NBR 8145)


Input

Voltage
Current
Power consumption

Rated frequency
Overload
The transformer (1) attenuates the input signal for the rectifier (2) and
effectuates a galvanic isolation between the in- and output signals. The
amplifier (3) converts the input signal into an output of alternating
voltage or current.
The rectifier (2) and the output module (3) need an auxiliary power
supply (4).

Characteristic curves

Output

Current

Signal limit
Load limit
Voltage
Residual ripple

Power supply

0..100/110/220/380/500V
(others on consult)
01A ou 05A (others on consult)
Voltage version: 0,65VA for class 0,5%
1,00VA for class 0,25%
Current version: 0,15VA
50;60 Hz 10% (others on consult)
permanently: 1,5 x UrtdI ; 2 x IrtdI
briefly: 4 x UrtdI/1s; 50 x IrtdI/1s
maximum: 250A/1s

0.20mA, 4...20mA,010V
(others on consult)
1,5 IrtdO, UrtdO mx.
25V; RC = infinite
Rc=
15.000(mV)

max. output signal (mA)


p.ex.: Rc=750 for 20mA
0...10V; Rc500 (other by consulting)
0,5% (peak to peak)

85265Vca e 90300Vcc
2060Vca/Vcc
consumption: 3W aprox.

Transducer ETM 50

Data Sheet - N00393/9

For alternating current or voltage

Influence Magnitudes
Error limit

Reference condictions
Input:

Frequency:
Form factor:
Auxiliary Power supply:
Load:
Ambient temperature:
Heat up time:
Additional error above
1,2IrtdI or UrtdI
Linearity deviation
Load
Temperature
Auxiliary power supply

Response time
External magnetic fields
Radio frequency
interference

Electrical Test
Test voltage

Surge Voltage
Radio frequency

0,5% (standard)
0,25% (option)
UI = UrtdI
II = 0...IrdtI for sinusoidal
electrical magnitudes without
zero displacement
frtdI 2%
1,111
UAX 2%
0,5 RC mx.
25C 2K
. 20 min
0,2%
0,2% (included in error limit)
0,05% RC = 0....RC mx.
(included in error limit)
0,2% /10 K; rated
temperature 25C
0,05% within the permitted
tolerance range for the supply
voltage
voltage
200 ms
0,5% for field intensity of
0,4 kA/m
0,5% between 27...460MHz
at a distance of 1m; power 1W
Uax. 85V : 2,5kV/1mim ; 60Hz
(for all circuits mutually).
Uax. 60V : 1,5kV/1min ; 60Hz
(for all circuits mutually).
5kV; 1,2/50us; 0,5Ws
2,5kV;1MHz; 400 pulsos / 1s

Notes:
- With respect to the output span.
- UrtdI = Rated voltage
- IrtdI = Rated Current
Response times below 200ms result in bigger residual ripple.

Page 2/4
July 2005

Construction and Mounting


Construction
Material
Fastening
Eletrical connection
Protection class
Weight

Climatic conditions

In surface mouting case


Polyamide UL94 VO
Surface mouting using DIN rail.
Terminals for pin shaped cable shoes.
IP 40 housing
IP 20 connection terminal
0,1 kg

Operation temperature
Functioning temperature
Transport and storage
temperature
Relative humidity

Mechanical test

Impact
Vibration

-20...+60C
-25...+70C
-40+80C
75% of anual average, with
light condensation
(others on consult)
acceleration 30g ; during 11ms
acceleartion 2g ;frequency
5..150Hz

Transducer ETM 50

Data Sheet - N00393/9

For alternating current or voltage

Page 3/4
July 2005

Additional information

Electric Conections

II
II , UI
UAx
O1

5
UI

=
=
=

13 14

+ _
61 62

UAX

O1

Input Current or Voltage


Auxiliary power supply
Output current or voltage

Dimensional Drawing
Dimensions in mm

The following items contain tips and cautions to be observed by


the user for a good functional performance, as well as the
maintenance of the instrument and the saftey of the installations.

Cautions

Be sure the voltage and current to be connected to the instrument,


are compatible.
Loosen all connections from the instrument before removing it
from the installation.

Mounting Instructions

Observe the ambient temperature range. At the place of


installation, values for vibration, dust, dirt and humidity, which
must remain between the limits, established by the protection class
of the housing and the climatic group, especified in this data sheet,
have to be observed.

For mounting on DIN rail, use the snap-in device on the rear of the
instrument.
The connections can be made with pin for shaped cable shoes.

Instructions for Use

When connections have been made, switch on the power supply


and check at the output the functioning of the transducer.

Transducer ETM 50

Data Sheet - N00393/9

For alternating current or voltage

Page 4/4
July 2005

Ordering information
Catalog number
TRANSDUCER ETM-50 for alternated current or alternated voltage

Housing
Normal
RMS

3
9

Rated Frequency
50 Hz
60 Hz
400 Hz
Others

1
2
3
0

Measuring range:
Voltage: between 0...10 up to 0..20VAC
between 0...21 up to 0...50VAC
between 0...51 up to 0...97VAC
between 0...98 up to 0...180VAC
between 0...181 up to 0...340VAC
between 0...341 up to 0...600VAC
Current: 0...1A
0...5A
Others
Auxiliary Power Supply
2060Vca/Vcc
85265Vca and 90300Vcc

1
2
3
4
5
6
7
8
0
12
13

Output Signal
0...20mADC
4...20mADC
0...10VDC
Others( 0...1mAdc at 20mAdc e 0...1Vdc at 0...15Vdc)
Optional
Error Limit 0,25%
Others response times between 50ms and 2s
Standard (Class 0,5%)
Additional information
Standard
Complement (Inform input signal voltage)

For quoting and ordering please issue your order according to the specification text.
Example:
Transducer ETM 50
Rated frequency:
60Hz
Measuring range:
05A
AuxiliaryPower supply:
85265Vca e 90300Vcc
Output Signal:
420mADC
Options:
Error limit 0,25%
Additional information:
Standard
Code number : N003932813511

ABB Ltda - ATIM/I Instrumentation Electrical


Avenue Dos Autonomistas, 1496 - 06020-902 - Osasco - SP
Phone: +55 11 3688-8320 / 8323 / 8347 - Fax: +55 11 3688-8322
instrumentacao@br.abb.com

4
5
6
0
1
4
5
1
C