BYSSY SYSTEM
BySSy has designed an
alternative refrigeration system that
is highly efficient. By using a closed
circuit it prevents the loss of water
through evaporation, which allows
the
systems
condensation
temperature to be lower. As a result
performance is improved even
during the hottest months of the
summer.
Because the water that is
used in BySSy system is not lost
through evaporation, it not only
eliminates the risk of releasing
water particles that might be
contaminated with legionella but
also does not produce any
atmospheric
emissions.
This
makes
the
product
very
environmentally
friendly
and
prevents it from contaminating.
In addition, not losing
water to evaporation greatly
reduces water consumption, which
is one of the biggest drawbacks of
refrigeration
towers.
The
performance of the refrigeration
equipment is also improved and its
useful life increased, thanks to
cooling the water at lower
temperatures and a reduction in the
level of deposits that can clog
tubing.
Further, there is less risk
of equipment corroding which
lowers maintenance costs.
Energy consumption is
significantly lowered thanks to the
reduction in the condensation
temperature.
Byssy system is thereby
able to offer an improved
Coefficient of Performance (COP),
which translates into energy
savings of between 15% and 20%.
This is a significant advantage for
companies that are heavy users of
air conditioning equipment.
1. ESQUEMAS
No es necesario la aditivacin del agua con biocidas, correctores del pH, inhibidores de la corrosin,
etc., para mantener el sistema en condiciones higinico-sanitarias y tcnicas correctas, as como la
realizacin de toma de muestras y ensayos de laboratorio para el control.
Es de circuito de agua cerrado, por lo que no existen consumos de agua por explotacin, ni el consumo
de aditivos para la misma, ni tratamiento previo de estas. El ahorro de agua por s solo, ya justifica la
utilizacin de estos equipos.
No exponen a ensuciamiento ni contaminacin, al agua o fluido de recirculacin.
Mayor salto trmico de diseo y menor caudal de agua en circulacin, lo que implica menor potencia
de la bomba.
No existe precipitacin de sales, ni concentracin de ests.
Regulable segn demanda.
Mnimo mantenimiento anual.
Elimina totalmente el riesgo de contaminacin por legionella al quedar libres de contaminacin desde
el resto del sistema.
2
2. ESQUEMA DE FUNCIONAMIENTO
3. ESQUEMAS ELCTRICOS
4.1 ESQUEMA ELCTRICO 1
ff
Compresor
13-2SC-26
15-2SC-30
15-3SC-45
08-4SC-32
10-4SC-40
13-4SC-52
15-4SC-60
135.77
25.32
169.71
33.00
254.57
49.55
181,03
35.59
226,29
46.76
294,17
59.02
339.43
66.49
3000x1060x2000
4000x2200x2000
1475
45 dba
Scroll
1505
45
Scroll
1580
48
Scroll
1540
47
Scroll
1575
47
Scroll
1640
48
Scroll
1680
48
Scroll
SZ-160
13 CV
37.7
SZ-185
15 CV
43.5
SZ-185
15 CV
43.5
SZ-100
8 CV
22.1
SZ-120
10 CV
29.0
SZ-160
13 CV
37.7
SZ-185
15 CV
43.5
3.25 L
POE-160SZ
4.00 L
POE-160SZ
6.20 L
POE-160SZ
65 w
7/8
75 w
20
3.4
3.25 L
POE-160SZ
3.25 L
POE-160SZ
3.25 L
POE-160SZ
Refrigerante
Caldern
Presin diferencial de
tarado (bar rel.)
Seccin de paso (mm2)
Capacidad de descarga a la
P. de tarado (kg/h)
Tipo
Limitador
Marca
de presin
Modelo
Presin de tarado (bar rel.)
Separador de aceite
Filtro deshidratador
Resistencia de crter
N
Dimetro (mm)
Tipo
Ventilador
Alimentacin elctrica
Regulacin de velocidad
Caudal aire nominal (m3/h)
Potencia absorbida mxima
(W)
r.p.m.
Alimentacin elctrica
Mx. intensidad en funcionamiento
continuo
(por cada compresor) (A)
Intensidad a rotor bloqueado (por cada
compresor) (A)
Intensidad mx. absorbida ventilador(es)
(A)
3.25 L
POE-160SZ
Vlvula de
seguridad
4000x2200x2000
17.72
379
65 w
ACB
Danfoss
061D6052
28
Opcional
5/8
65 w
65 w
65 w
1
65 w
2
800
Axial
240V-I-50 hz
400V-III-50 hz
22000
22000
Variador de tensin
46000
46000
2000
2000
3700
29
35
35
150
175
175
3700
900
400 V-III-50 Hz
19
98
46000
44000
44000
3700
4000
4000
29
29
35
130
150
3.90
175
7.80
Temperatura exterior: 35 C
Sobrecalentamiento: 10K
Temperatura de evaporacin: -10 C
Subenfriamiento: 3 K
2
Potencia total absorbida por compresor y ventiladores en condiciones nominales.
3
Definicin dada en el RD 138/2011 Reglamento de seguridad para instalaciones frigorficas y sus I.T.
complementarias. IF 01.
4
Nivel de presin sonora a 10 m de la unidad moto-condensadora medido en campo abierto.
5. DIMENSIONES Y PESO
SERIE 1/MODELO: 13-2SC-26; DIMENSIONES: 3.000X1.060X2.000; PESO: 1.475 KG.
SERIE 1/MODELO: 15-2SC-30; DIMENSIONES: 3.000X1.060X2.000; PESO: 1.505 KG.
SERIE 1/MODELO: 15-3SC-45; DIMENSIONES: 4.000X2.200X2.000; PESO: 1.580 KG.
SERIE 1/MODELO: 08-4SC-32; DIMENSIONES: 4.000X2.200X2.000; PESO: 1.540 KG.
SERIE 2/MODELO: 10-4SC-40; DIMENSIONES: 4.000X2.200X2.000; PESO: 1.575 KG.
SERIE 2/MODELO: 13-4SC-52; DIMENSIONES: 4.000X2.200X2.000; PESO: 1.640 KG.
SERIE 2/MODELO: 15-4SC-60; DIMENSIONES: 4.000X2.200X2.000; PESO: 1.680 KG.
SERIE 1
SERIE 2
6. ESPECIFICACIONES TCNICAS
BySSy
Equipo de
refrigeracin
de alto
rendimiento
BySSy consigue en un slo elemento:
Ahorro de Agua
Temperatura Constante de trabajo
Mejor Aprovechamiento Energtico
Absoluta Seguridad Medioambiental