Beruflich Dokumente
Kultur Dokumente
TECH3000
38EYX/FX4CSX
Nominal cooling capacity 6.8-16.7 kW
Nominal heating capacity 6.6-17.1 kW
The 38EYX/FX4CSX direct-expansion split-system heat
pumps are designed to give quiet, reliable heating during
the winter or cooling during the summer. As reversible airto-air heat pump systems they recover heat for indoor
comfort from outdoor air during the heating season and
reverse automatically to remove indoor heat and excess
humidity during the cooling season, providing excellent
comfort all year round. They are designed for light
commercial and residential applications and ideal for
installations in extreme temperature conditions. The system
runs on the ozone-friendly refrigerant R410A and consists
of the 38EYX outdoor unit sections and the FX4CSX
encased indoor fan coils, complete with direct-expansion
indoor coil.
System features
Four model combinations available, offering for highefficiency operation, application flexibility, ease of
installation and high-tech components.
The new design provides excellent energy efficiency (class
A and B), both in cooling and heating mode.
The TECH3000 system has been optimised to run on the
ecological R410A refrigerant.
Systems are offered in 230-1-50 (size 024) and 400-3-50
(sizes 036-060) power supplies. Three-phase systems
include a control board to monitor the electrical phases and
prevent compressor damage in the case of incorrect wiring.
Design and construction are in compliance with European
standards.
Performance data
Outdoor unit 38EYX
Indoor unit FX4CSX
024
024
036
036
048
048
060
060
kW
kW
W/W
kW/h
6.83
2.12
3.22
1060
A
9.98
3.14
3.18
1570
B
13.66
4.37
3.13
NA
NA
16.73
5.87
2.85
NA
NA
kW
kW
W/W
6.64
1.83
3.63
A
10.39
2.98
3.49
B
14.48
3.82
3.79
NA
17.07
5.03
3.39
NA
Physical data
Outdoor unit 38EYX
024
036
048
060
Operating weight
kg
65.8
83.9
99.3
111.6
Refrigerant
Charge
kg
R-410A
2.61
3.69
4.82
6.35
Compressor
Outdoor fan
Air discharge
Air flow
Motor speed
l/s
r/s
1416
15
1180
15
dB(A)
dB(A)
72/72
52/52
72/72
52/52
74/74
54/54
in
5/8 - 3/8
3/4 - 3/8
7/8 - 3/8
7/8 - 3/8
Maximum elevation
Maximum pipe length
Pre-charged pipe length
Additional refrigerant charge
m
m
m
g/m
45**
50
4.5
56
45**
50
4.5
56
45**
50
4.5
56
45**
50
4.5
56
024
036
048
060
kg
55
67
72
80
l/h
3.4
4.6
7.0
8.2
Fan type
Nominal air flow
Max. static pressure
l/s
Pa
750
125
825
125
dB(A)
dB(A)
72
56
77
61
77
61
80
64
in
5/8 - 3/8
3/4 - 3/8
7/8 - 3/8
7/8 - 3/8
72/72
52/52
* Sound pressure level is measured in a hemispheric field at 4 m distance from the unit.
** If the outdoor unit is positioned below the indoor unit the maximum elevation is 15 m.
*** Sound pressure level is measured in an anechoic room at 1.28 m distance from a discharge outlet on the wall.
Electrical data
38EYX
Power supply
Voltage range
Compressor LRA
Compressor RLA
Fan full load current
Max. operating current
Fuse rating*
024
036
048
060
V-ph-Hz
V
A
A
A
A
A
230-1-50
187-253
61
12.5
0.6
16.2
25
400-3-50
360-440
48
6.4
0.7
8.7
15
400-3-50
360-440
64
9.0
0.7
12.0
20
400-3-50
360-440
74
10.6
0.7
14.0
20
024
036
048
060
A
A
A
V-ph-Hz
1.5
1.9
15
230-1-50
1.8
2.3
15
230-1-50
2.7
3.4
15
230-1-50
3.6
4.5
15
230-1-50
FX4CSX
Full load current
Minimum circuit current
Fuse rating
Power supply
* Time-delay fuse
Note: The control circuit is 24 V on all units and requires an external power source. Copper wire must be used from the disconnect to the unit.
All motors/compressors contain internal overload protection.
LRA - Locked rotor current, A
RLA - Rated load current, A
Operating limits
38EYX size
Outdoor piston
Indoor piston
024-70
036-90
048-90
060-90
40
49
65
73
52
65
76
88
Cooling mode
Heating mode
52C
32C db/23C wb
19C db/18C wb
27C db
13C*
21C db/15C wb
-34C db
-
* With low-ambient kits the minimum outdoor temperature in cooling mode is -29C.
Sound
size
level
125
250
500
1000
2000
4000
8000
024
72
76.0
69.0
66.0
65.5
61.5
58.0
56.0
036
72
71.5
68.0
68.5
67.5
65.5
61.5
53.5
048
72
67.5
66.0
69.5
67.5
63.0
60.5
57.0
060
74
70.0
68.5
68.5
69.0
65.5
61.5
55.5
Sound
size
rating
63
125
250
500
1000
2000
4000
8000
024
72
68.5
69.0
66.0
68.5
67.0
65.0
64.5
58.5
036
77
69.5
71.5
70.5
71.5
71.0
69.5
70.0
63.5
048
77
70
72.5
71.5
71.5
71.5
70.0
70.5
64.5
060
80
75.5
76.5
75.5
73.5
73.5
72.5
73.5
69.5
Sound power levels in accordance with Eurovent standards 6/C/006-97 and 8/4.
Dimensions 38EYX
A
Air discharge
Air in
sq.
Air discharge
N
J
K
L
Air in
Air in
B
3/8" dia. liquid line
connection
3/8" dia.
tie-down
knockouts
(2) places
P
Air
discharge
73 mm
Air in
dia. vapour line connection
F
G
32 mm
H
Notes:
1.Allow 760 mm clearance to service side of unit, 1220 mm above unit, 150 mm on one side, 300 mm on remaining side, and 610 mm between units for proper air flow.
2.Minimum outdoor operating ambient in cooling mode is 13C (unless low ambient control is used), max. 52C.
3.Maximum outdoor operating ambient in heating mode is 19C.
4.Series designation is the 13th position of the unit model number.
5.Centre of gravity
Unit dimensions
38EYX
024
036
048
060
Series A
70
90
90
90
mm
571.5
762.0
762.0
762.0
Minimum mounting
mm
760.4
760.4
1014.4
862.0
mm
81.0
81.0
82.6
82.6
in
5/8
3/4
7/8
7/8
mm
93.7
165.1
165.1
165.1
mm
460.4
596.9
596.9
596.9
mm
501.7
692.2
692.2
692.2
mm
549.3
739.8
739.8
739.8
mm
365.1
508.0
508.0
508.0
mm
479.4
669.9
669.9
669.9
mm
560.4
750.9
750.9
750.9
mm
279.4
406.4
381.0
349.3
mm
127.0
355.6
400.1
396.9
mm
355.6
317.5
355.6
381.0
pad dimensions, mm
571.5 x 571.5
762.0 x 762.0
762.0 x 762.0
762.0 x 762.0
FX4CSX
Size
024
036
048
060
Series
A
A
A
A
Coil
type
Slope
Slope
A
A
A
mm
1212
1357
1261
1357
B
mm
448
537
537
537
C
mm
400
489
489
489
25
265
67
24
48
D
mm
397
486
486
486
127
J
mm
432
463
Front view
Inlet air
Opening
D
Fitting
panel
Top view
49
7/8"/1-3/32"/
2" dia.
knockouts for
high-voltage
power wiring
Filter access
panel
157
Suction line
connection
Liquid line
connection
Disconnect or
circuit breaker
location
39
25
7/8" dia.
knockouts for
low-voltage
control wiring
241
Suction
line
connection
Liquid line
connection
3/8" ID sweat
3/4" fit
273
78
119
Liquid:
Condensate:
Liquid line
connection
Inlet air
Alternative
7/8" dia.
knockout for
low-voltage
control wiring
54
32
44
30
560
Outlet air
279
64
38
19
22
Notes:
1. Series designation is the 14th position of the units product number.
2. Allow 533 mm from front for service.
Inlet air
Opening
503
483
Alternative7/8"/1-3/32"/
2" dia. knockouts for
high-voltage power
wiring (opposite side)
1"
259
FX4CSX Dimensions
FX4CSX
size
024
036
048
060
22
typ.
A
A
A
A
Primary drain
46
200
Coil
type
Slope
Slope
A
A
Horizontal left
(as shipped)
38
149
Horizontal left
(as shipped)
Secondary drain
Series
13 typ
22
typ.
13
typ.
Primary drain
Secondary drain
127
56 typ.
(2 places)
F
mm
587
684
593
692
46
typ*
10
typ*
G
mm
600
699
587
684
56 typ.
(2 places)
Secondary drain
Primary drain
73
41
10
32
46
typ.
Secondary drain
Primary drain
68
79
32
83
121
81
25 typ.
(2 places)
Primary drain
25 typ.
(2 places)
11 typ.
(4 places
65
73
Secondary drain
Primary drain
25 typ.
(2 places)
11 typ. (2 places)
Air flow
Downflow
(field converted)
11 typ.
(4 places)
Air flow
Downflow
(field converted)
11 typ.
(4 places)
Primary drain
46 typ.
25 typ.
(2 places)
54
200
149
10 typ.
Horizontal right
(field converted)
10 typ.
Secondary drain
Secondary drain
56 typ.
(2 places)
46
56 typ.
(2 places)
Upflow
(as shipped)
81
121
Air flow
83
Upflow
(as shipped)
32
Air flow
13
Horizontal right
(field converted)
46
38
22
typ.
13 typ
Secondary drain
Primary drain
32
41
22
EWB
36
l/s
TC
TC
SC
kW
TC
SC
kW
40
44
48
52
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
TC
SC
kW
22
20
18
16
14
7.35
7.17
6.93
6.71
6.63
3.86
4.64
5.49
6.45
6.63
1.78
1.77
1.76
1.74
1.74
7.18
7.00
6.79
6.49
6.45
3.81
4.62
5.53
6.36
6.45
1.99
1.98
1.96
1.94
1.94
6.99
6.84
6.57
6.26
6.25
3.74
4.60
5.48
6.26
6.25
2.18
2.16
2.15
2.13
2.13
6.85
6.62
6.32
6.03
6.03
3.72
4.53
5.39
6.03
6.03
2.38
2.36
2.34
2.33
2.33
6.58
6.34
6.04
5.80
5.80
3.62
4.44
5.29
5.80
5.80
2.59
2.57
2.55
2.54
2.54
6.28
6.04
5.73
5.54
5.54
3.51
4.33
5.16
5.54
5.54
2.81
2.79
2.77
2.77
2.76
5.94
5.70
5.39
5.26
5.27
3.39
4.20
5.02
5.26
5.27
3.04
3.02
3.00
2.99
2.99
380
22
20
18
16
14
7.39
7.20
6.99
6.79
6.77
3.93
4.77
5.70
6.79
6.77
1.80
1.80
1.78
1.77
1.77
7.20
7.01
6.85
6.61
6.61
3.88
4.73
5.78
6.61
6.61
2.01
2.00
1.98
1.97
1.97
7.01
6.89
6.64
6.42
6.42
3.82
4.77
5.75
6.42
6.42
2.21
2.19
2.17
2.16
2.16
6.87
6.66
6.39
6.21
6.21
3.81
4.70
5.68
6.21
6.21
2.41
2.39
2.37
2.36
2.36
6.61
6.39
6.11
5.97
5.97
3.73
4.62
5.58
5.97
5.97
2.61
2.59
2.58
2.57
2.57
6.31
6.08
5.80
5.70
5.71
3.62
4.52
5.46
5.70
5.71
2.84
2.82
2.80
2.79
2.79
5.96
5.74
5.46
5.42
5.42
3.49
4.40
5.30
5.42
5.42
3.07
3.05
3.03
3.02
3.02
425
22
20
18
16
14
7.40
7.23
7.02
6.85
6.84
4.00
4.88
5.88
6.85
6.84
1.83
1.82
1.81
1.79
1.79
7.22
7.04
6.87
6.71
6.71
3.95
4.85
5.98
6.71
6.71
2.03
2.02
2.01
2.00
2.00
7.03
6.90
6.68
6.53
6.53
3.89
4.88
5.98
6.53
6.53
2.23
2.21
2.19
2.19
2.19
6.84
6.69
6.44
6.32
6.32
3.83
4.86
5.93
6.32
6.32
2.43
2.41
2.39
2.39
2.39
6.63
6.42
6.16
6.08
6.08
3.81
4.79
5.81
6.08
6.08
2.64
2.62
2.60
2.60
2.60
6.32
6.10
5.85
5.81
5.81
3.71
4.69
5.69
5.81
5.81
2.86
2.84
2.82
2.82
2.82
5.97
5.76
5.52
5.51
5.51
3.58
4.57
5.52
5.51
5.51
3.09
3.07
3.05
3.05
3.05
22
20
18
16
14
11.22
10.76
10.21
9.58
9.55
5.99
7.22
8.52
9.58
9.55
2.69
2.66
2.63
2.62
2.62
10.93
10.46
9.77
9.23
9.22
5.91
7.19
8.37
9.23
9.22
2.95
2.92
2.90
2.89
2.89
10.70
10.08
9.37
8.90
8.90
5.87
7.07
8.20
8.90
8.90
3.20
3.17
3.15
3.14
3.14
10.31
9.66
8.93
8.56
8.56
5.76
6.91
8.02
8.56
8.56
3.46
3.43
3.41
3.40
3.40
9.88
9.20
8.46
8.19
8.20
5.60
6.74
7.80
8.19
8.20
3.74
3.71
3.69
3.68
3.68
9.40
8.70
7.95
7.80
7.80
5.43
6.55
7.56
7.80
7.80
4.04
4.01
3.99
3.98
3.98
8.87
8.17
7.44
7.39
7.39
5.24
6.34
7.30
7.39
7.39
4.35
4.32
4.30
4.29
4.29
560
22
20
18
16
14
11.29
10.86
10.36
9.92
9.93
6.16
7.54
9.04
9.92
9.93
2.74
2.71
2.68
2.67
2.67
11.01
10.59
9.94
9.58
9.58
6.10
7.56
8.91
9.58
9.58
3.00
2.97
2.95
2.94
2.94
10.73
10.22
9.54
9.25
9.25
6.03
7.46
8.76
9.25
9.25
3.25
3.22
3.20
3.19
3.19
10.42
9.79
9.10
8.90
8.90
5.99
7.32
8.56
8.90
8.90
3.51
3.48
3.46
3.45
3.45
9.98
9.33
8.63
8.53
8.53
5.85
7.16
8.34
8.53
8.53
3.79
3.76
3.74
3.74
3.74
9.49
8.84
8.17
8.14
8.14
5.69
6.99
8.10
8.14
8.14
4.09
4.06
4.03
4.03
4.03
8.97
8.29
7.70
7.70
7.71
5.50
6.77
7.70
7.70
7.71
4.40
4.37
4.35
4.35
4.35
640
22
20
18
16
14
11.33
10.52
10.47
10.18
10.18
6.31
7.13
9.49
10.18
10.18
2.78
2.77
2.73
2.72
2.72
11.06
10.66
10.08
9.85
9.85
6.28
7.88
9.40
9.85
9.85
3.05
3.02
2.99
2.99
2.99
10.77
10.31
9.67
9.52
9.53
6.21
7.83
9.24
9.52
9.53
3.30
3.27
3.24
3.24
3.24
10.49
9.89
9.25
9.17
9.17
6.21
7.71
9.03
9.17
9.17
3.56
3.53
3.51
3.50
3.50
10.04
9.43
8.79
8.80
8.80
6.07
7.56
8.79
8.80
8.80
3.84
3.81
3.79
3.79
3.79
9.55
8.92
8.38
8.39
8.39
5.92
7.38
8.38
8.39
8.39
4.14
4.11
4.09
4.08
4.08
9.02
8.38
7.95
7.95
7.95
5.74
7.18
7.95
7.95
7.95
4.45
4.42
4.40
4.40
4.40
22
20
18
16
14
14.88
14.47
14.05
13.42
13.19
7.76
9.30
11.07
12.72
13.19
3.61
3.59
3.56
3.55
3.55
14.46
14.16
13.59
12.93
12.78
7.59
9.26
10.94
12.50
12.78
4.07
4.03
4.01
4.00
4.00
14.19
13.69
13.11
12.46
12.38
7.53
9.09
10.73
12.24
12.38
4.48
4.45
4.43
4.42
4.42
13.63
13.17
12.59
11.96
11.95
7.30
8.87
10.52
11.96
11.95
4.92
4.89
4.87
4.85
4.85
13.06
12.61
12.03
11.48
11.48
7.08
8.65
10.29
11.48
11.48
5.38
5.35
5.32
5.31
5.31
12.41
11.98
11.41
10.96
10.96
6.82
8.39
10.03
10.96
10.96
5.86
5.82
5.79
5.78
5.78
11.69
11.28
10.72
10.40
10.40
6.53
8.10
9.72
10.40
10.40
6.34
6.31
6.27
6.25
6.25
730
22
20
18
16
14
14.94
14.54
14.13
13.59
13.48
7.87
9.51
11.41
13.23
13.48
3.66
3.64
3.62
3.60
3.59
14.50
14.21
13.71
13.11
13.06
7.71
9.48
11.36
13.01
13.06
4.12
4.09
4.06
4.05
4.04
14.21
13.77
13.22
12.66
12.66
7.64
9.34
11.14
12.66
12.66
4.53
4.50
4.48
4.46
4.46
13.67
13.23
12.69
12.22
12.22
7.45
9.12
10.93
12.22
12.22
4.97
4.94
4.92
4.90
4.90
13.09
12.67
12.13
11.74
11.74
7.22
8.90
10.71
11.74
11.74
5.43
5.40
5.37
5.36
5.36
12.44
12.03
11.51
11.21
11.21
6.95
8.65
10.45
11.21
11.21
5.91
5.88
5.84
5.83
5.83
11.71
11.32
10.81
10.62
10.62
6.67
8.36
10.13
10.62
10.62
6.39
6.36
6.32
6.31
6.31
800
22
20
18
16
14
14.99
14.61
14.17
13.80
13.79
8.04
9.82
11.84
13.80
13.79
3.74
3.72
3.70
3.67
3.68
14.54
14.23
13.83
13.38
13.38
7.89
9.78
11.99
13.38
13.38
4.20
4.17
4.15
4.13
4.13
14.17
13.86
13.33
12.97
12.97
7.76
9.73
11.76
12.97
12.97
4.61
4.58
4.56
4.55
4.55
13.72
13.30
12.80
12.51
12.51
7.66
9.50
11.55
12.51
12.51
5.05
5.02
5.00
4.98
4.98
13.11
12.72
12.24
12.02
12.02
7.41
9.29
11.32
12.02
12.02
5.51
5.49
5.45
5.44
5.44
12.46
12.08
11.61
11.47
11.47
7.15
9.04
11.03
11.47
11.47
5.99
5.96
5.92
5.92
5.92
11.74
11.36
10.91
10.85
10.85
6.87
8.75
10.67
10.85
10.85
6.48
6.44
6.40
6.40
6.40
22
20
18
16
14
19.59
18.56
17.25
16.14
16.05
10.37
12.34
14.22
15.94
16.05
5.21
5.15
5.11
5.08
5.08
18.78
17.75
16.58
15.51
15.51
10.03
12.03
13.92
15.51
15.51
5.65
5.59
5.53
5.51
5.50
18.04
17.06
15.89
14.98
14.98
9.76
11.73
13.61
14.98
14.98
6.05
5.98
5.93
5.91
5.91
17.22
16.31
15.19
14.43
14.43
9.43
11.42
13.29
14.43
14.43
6.46
6.40
6.34
6.32
6.32
16.37
15.49
14.40
13.82
13.82
9.08
11.07
12.94
13.82
13.82
6.90
6.83
6.77
6.75
6.75
15.41
14.62
13.58
13.18
13.18
8.68
10.70
12.56
13.18
13.18
7.34
7.27
7.21
7.19
7.19
14.27
13.64
12.73
12.48
12.49
8.17
10.25
12.13
12.48
12.49
7.78
7.71
7.64
7.64
7.64
875
22
20
18
16
14
19.64
18.61
17.32
16.22
16.17
10.44
12.48
14.40
16.19
16.17
5.24
5.18
5.13
5.10
5.10
18.82
17.81
16.64
15.64
15.64
10.10
12.16
14.11
15.64
15.64
5.67
5.61
5.55
5.52
5.52
18.08
17.10
15.95
15.10
15.10
9.83
11.86
13.79
15.10
15.10
6.07
6.01
5.96
5.93
5.93
17.25
16.35
15.24
14.55
14.55
9.50
11.55
13.48
14.55
14.55
6.49
6.42
6.37
6.34
6.34
16.39
15.53
14.45
13.93
13.93
9.14
11.20
13.12
13.93
13.93
6.92
6.85
6.80
6.78
6.78
15.40
14.66
13.63
13.28
13.28
8.74
10.82
12.73
13.28
13.28
7.36
7.29
7.23
7.22
7.22
14.28
13.66
12.76
12.58
12.58
8.22
10.35
12.29
12.58
12.58
7.80
7.74
7.67
7.66
7.66
900
22
20
18
16
14
19.67
18.67
17.38
16.32
16.30
10.51
12.60
14.59
16.32
16.30
5.26
5.20
5.15
5.12
5.12
18.85
17.86
16.70
15.76
15.76
10.17
12.29
14.29
15.76
15.76
5.69
5.63
5.58
5.55
5.55
18.10
17.15
16.00
15.22
15.22
9.90
11.99
13.97
15.22
15.22
6.09
6.03
5.98
5.95
5.95
17.27
16.39
15.29
14.66
14.66
9.57
11.67
13.65
14.66
14.66
6.51
6.44
6.39
6.36
6.36
16.41
15.57
14.51
14.04
14.04
9.20
11.32
13.29
14.04
14.04
6.94
6.88
6.82
6.80
6.80
15.41
14.69
13.68
13.38
13.38
8.79
10.94
12.89
13.38
13.38
7.38
7.31
7.25
7.24
7.24
14.28
13.68
12.81
12.67
12.67
8.27
10.46
12.44
12.67
12.67
7.83
7.76
7.69
7.69
7.69
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or indoor unit is located above outdoor
unit, a slight variation in capacity may occur.
Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
Sensible capacities shown are based on 27C entering air at the indoor coil. For sensible capacities at other than 27C, deduct 245 W per 480 l/s of indoor coil air for each degree below
27C, or add 245 kW per 480 l/s of indoor coil air per degree above 27C.
** System kW is total of indoor and outdoor unit kilowatts.
EWB - Entering wet bulb temperature, C
TC
- Total cooling capacity, kW
SC - Sensible capacity, kW
kW - System power input
TCI
kW
4
TC
TCI
kW
8
TC
TCI
kW
12
TC
TCI
kW
16
TC
TCI
kW
20
TC
TCI
kW
330
380
425
3.61
3.65
3.69
3.32 1.28
3.36 1.27
3.39 1.27
4.71
4.76
4.80
4.29
4.33
4.37
1.37
1.36
1.35
5.90
5.79
5.69
5.12
5.02
4.93
1.48
1.44
1.43
6.31
6.13
5.89
6.16
5.98
5.75
1.52
1.48
1.45
6.66
6.23
5.89
6.66
6.23
5.89
1.57
1.49
1.45
6.78
6.27
5.90
6.78
6.27
5.90
1.58
1.49
1.45
6.85
6.30
5.89
6.85
6.30
5.89
1.58
1.49
1.45
6.91
6.30
5.56
6.91
6.30
5.56
1.58
1.49
1.43
15
330
380
425
3.54
3.58
3.62
3.26 1.37
3.30 1.36
3.33 1.36
4.64
4.69
4.73
4.23
4.27
4.31
1.46
1.45
1.44
5.92
5.85
5.77
5.13
5.07
5.00
1.59
1.55
1.53
6.38
6.23
6.10
6.22
6.08
5.95
1.64
1.60
1.57
6.77
6.52
6.19
6.77
6.52
6.19
1.69
1.63
1.58
7.08
6.60
6.23
7.08
6.60
6.23
1.73
1.64
1.58
7.19
6.65
6.26
7.19
6.65
6.26
1.73
1.64
1.58
7.29
6.70
6.25
7.29
6.70
6.25
1.74
1.64
1.58
18
330
380
425
3.47
3.52
3.55
3.20 1.47
3.23 1.45
3.27 1.45
4.58
4.62
4.66
4.17
4.21
4.25
1.57
1.55
1.54
5.87
5.88
5.83
5.09
5.10
5.05
1.70
1.66
1.64
6.42
6.31
6.19
6.26
6.15
6.04
1.76
1.71
1.69
6.85
6.67
6.45
6.85
6.67
6.45
1.82
1.76
1.72
7.27
6.88
6.53
7.27
6.88
6.53
1.87
1.78
1.72
7.49
6.97
6.58
7.49
6.97
6.58
1.90
1.79
1.73
7.62
7.06
6.62
7.62
7.06
6.62
1.91
1.80
1.73
21
330
380
425
3.41
3.45
3.48
3.14 1.56
3.17 1.55
3.20 1.55
4.51
4.56
4.59
4.11
4.15
4.18
1.67
1.65
1.64
5.80
5.84
5.85
5.03
5.06
5.07
1.83
1.78
1.76
6.43
6.35
6.26
6.28
6.20
6.11
1.88
1.84
1.81
6.90
6.76
6.62
6.90
6.76
6.62
1.95
1.89
1.85
7.36
7.13
6.79
7.36
7.13
6.79
2.01
1.94
1.87
7.74
7.25
6.87
7.74
7.25
6.87
2.06
1.95
1.88
7.90
7.42
6.94
7.90
7.42
6.94
2.08
1.97
1.88
24
330
380
425
3.35
3.38
3.41
3.08 1.66
3.11 1.66
3.14 1.65
4.44
4.49
4.53
4.05
4.09
4.13
1.78
1.76
1.75
5.72
5.77
5.80
4.95
5.00
5.03
1.94
1.91
1.88
6.40
6.38
6.31
6.25
6.22
6.16
2.01
1.96
1.93
6.92
6.82
6.70
6.92
6.82
6.70
2.08
2.02
1.98
7.42
7.24
7.02
7.42
7.24
7.02
2.15
2.08
2.02
7.86
7.49
7.13
7.86
7.49
7.13
2.22
2.11
2.03
8.11
7.63
7.24
8.11
7.63
7.24
2.20
2.12
2.04
500
560
640
5.29
5.35
5.42
4.87 1.96
4.92 1.98
4.98 2.00
6.91
6.99
7.06
6.30
6.37
6.43
2.15
2.15
2.16
8.83
8.90
8.90
7.65
7.71
7.71
2.40
2.38
2.37
9.84
9.76
9.65
9.60
9.53
9.42
2.51
2.48
2.47
15
500
560
640
5.19
5.27
5.33
4.77 2.08
4.85 2.08
4.90 2.11
6.81
6.89
6.96
6.20
6.27
6.34
2.27
2.27
2.28
8.71
8.79
8.85
7.54
7.62
7.67
2.53
2.52
2.51
9.77
9.77
9.70
9.53
9.53
9.47
2.67
2.63
2.61
18
500
560
640
5.10
5.17
5.24
4.69 2.21
4.75 2.21
4.81 2.22
6.71
6.79
6.86
6.11
6.18
6.24
2.40
2.40
2.40
8.58
8.67
8.74
7.43
7.51
7.58
2.66
2.65
2.66
9.65
9.71
9.70
9.41
9.48
9.47
2.83
2.78
2.76
21
500
560
640
5.02
5.08
5.15
4.61 2.33
4.67 2.34
4.73 2.35
6.61
6.69
6.76
6.02
6.09
6.15
2.54
2.53
2.53
8.45
8.54
8.62
7.33
7.40
7.47
2.80
2.79
2.79
9.51
9.60
9.65
9.28
9.37
9.42
2.98
2.96
2.92
24
500
560
640
4.93
5.00
5.06
4.54 2.47
4.59 2.47
4.65 2.49
6.50
6.57
6.65
5.92
5.99
6.05
2.68
2.67
2.67
8.33
8.42
8.50
7.22
7.30
7.37
2.96
2.93
2.93
9.37
9.47
9.55
9.15
9.24
9.31
3.13
3.11
3.10
650
730
800
7.82
7.88
7.96
7.19 2.66
7.24 2.64
7.33 2.64
9.81
9.88
9.98
8.93
9.00
9.09
2.77
2.74
2.71
15
650
730
800
7.74
7.80
7.90
7.12 2.88
7.18 2.87
7.26 2.86
9.72
9.79
9.90
8.86
8.92
9.02
3.01
2.97
2.94
18
650
730
800
7.64
7.71
7.81
7.03 3.10
7.09 3.09
7.18 3.09
9.65
9.72
9.82
8.79
8.85
8.95
3.26
3.22
3.18
21
650
730
800
7.51
7.58
7.70
6.91 3.32
6.98 3.31
7.08 3.31
9.56
9.64
9.74
8.71
8.78
8.87
3.48
3.47
3.43
24
650
730
800
7.34
7.42
7.55
6.75 3.52
6.83 3.52
6.94 3.52
9.47
9.54
9.65
8.63
8.69
8.79
3.76
3.70
3.66
850
875
900
9.37
9.39
9.42
8.61 3.70
8.64 3.70
8.66 3.71
15
850
875
900
9.21
9.24
9.27
8.47 3.91
8.50 3.91
8.53 3.92
18
850
875
900
9.04
9.07
9.09
8.31 4.12
8.34 4.12
8.37 4.13
21
850
875
900
8.83
8.86
8.90
8.12 4.33
8.15 4.33
8.18 4.34
24
850
875
900
8.61
8.64
8.68
7.91 4.53
7.95 4.54
7.98 4.55
* The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
The kW heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The kW heating from supplement heaters should be added to those
values to obtain total system capacity.
EDB - Entering dry bulb temperature, C
TC
- Total instantaneous heating capacity, kW
TCI - Integrated heating capacity, kW
kW - Total power input
10
12
22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16
024 350
0.04
475
0.07
525
0.08
TC
SC
TC
SC
TC
SC
13.8
6.8
15.9
7.7
16.7
8.3
12.1
7.2
14.0
8.3
14.6
8.8
10.6
7.5
12.1
8.9
12.7
9.3
9.1
7.7
10.3
9.4
10.8
9.9
12.9
6.4
14.8
7.3
15.6
7.9
11.1
6.8
12.8
7.8
13.4
8.3
9.5
7.1
11.0
8.3
11.5
8.8
8.0
7.3
9.3
8.8
9.8
9.2
11.9
5.9
13.6
6.9
14.4
7.4
10.0
6.2
11.6
7.3
12.1
7.8
8.4
6.5
9.8
7.7
10.3
8.2
7.0
6.7
8.1
8.1
8.6
8.6
10.8
5.4
12.3
6.4
13.0
6.9
8.9
5.7
10.3
6.8
10.7
7.2
7.4
5.9
8.6
7.1
9.0
7.5
5.9
5.9
7.0
7.0
7.4
7.4
9.5
4.8
10.9
5.7
11.5
6.3
7.6
5.2
8.9
6.1
9.3
6.5
6.2
5.4
7.4
6.4
7.7
6.8
4.9
4.9
6.1
6.1
6.5
6.5
8.1
4.4
9.2
5.2
9.8
5.6
6.3
4.6
7.2
5.5
7.6
5.9
5.3
4.7
6.1
5.7
6.5
6.0
4.4
4.4
5.5
5.5
5.8
5.8
036 475
0.05
600
0.07
700
0.09
TC
SC
TC
SC
TC
SC
19.8
9.4
22.6
11.0
24.5
11.9
17.2
10.0
19.7
11.7
21.4
12.9
14.7
10.5
17.0
12.3
18.6
13.7
12.2
10.9
14.4
13.0
15.8
14.5
18.3
8.8
21.0
10.3
22.8
11.3
15.6
9.2
18.0
10.9
19.7
12.1
13.1
9.7
15.3
11.5
16.8
12.8
10.8
10.1
12.7
12.1
13.9
13.4
16.6
8.1
19.1
9.5
21.0
10.4
13.9
8.6
16.1
10.1
17.6
11.2
11.5
8.9
13.5
10.6
14.8
11.8
9.3
9.2
11.0
11.0
12.1
12.1
14.9
7.4
17.2
8.7
18.9
9.6
12.1
7.8
14.1
9.3
15.4
10.3
9.9
8.1
11.7
9.7
12.8
10.8
7.9
7.9
9.4
9.4
10.5
10.5
13.0
6.6
15.1
7.8
16.6
8.7
10.2
7.0
12.0
8.4
13.2
9.4
8.2
7.1
9.9
8.7
11.0
9.7
6.6
7.1
8.2
8.2
9.3
9.3
10.9
5.9
12.6
7.0
14.0
7.9
8.3
6.2
9.7
7.4
10.8
8.4
6.9
6.3
8.3
7.6
9.2
8.5
6.0
6.0
7.3
7.3
8.3
8.3
048 575
0.05
750
0.07
825
0.08
TC
SC
TC
SC
TC
SC
23.5
11.3
26.7
13.0
27.6
13.6
20.5
12.0
23.3
14.0
24.4
14.8
17.8
12.7
20.3
15.0
21.2
16.0
15.2
13.3
17.6
16.0
18.1
17.0
21.8
10.5
25.0
12.3
25.9
12.7
18.8
11.3
21.6
13.4
22.5
14.0
16.0
11.9
18.5
14.2
19.5
15.1
13.3
12.4
15.6
14.9
16.5
16.2
19.9
9.8
22.9
11.5
23.8
12.0
16.9
10.5
19.6
12.5
20.4
13.2
14.2
11.1
16.6
13.3
17.3
14.1
11.6
11.5
13.8
13.8
14.5
14.5
18.0
9.1
20.7
10.7
21.6
11.3
15.0
9.7
17.3
11.5
18.0
12.3
12.4
10.1
14.6
12.3
15.2
13.0
10.0
10.0
12.1
12.1
12.8
12.8
16.1
8.2
18.4
9.8
19.3
10.4
12.9
8.7
14.8
10.7
15.5
11.3
10.6
9.1
12.6
11.2
13.2
11.8
8.7
8.7
10.9
10.9
11.5
11.5
13.5
7.4
15.7
8.7
16.4
9.4
10.5
7.8
12.2
9.4
12.7
10.1
8.8
8.0
10.6
9.8
11.1
10.5
7.7
7.7
9.7
9.7
10.4
10.4
060 600
0.03
750
0.05
900
0.06
TC
SC
TC
SC
TC
SC
25.7
12.4
29.6
14.4
32.6
15.9
22.1
13.0
25.8
15.3
28.5
17.1
19.0
13.4
22.3
16.0
24.7
18.1
16.1
13.8
18.9
16.6
21.0
19.1
23.6
11.5
27.5
13.4
30.3
14.9
20.2
12.0
23.7
14.2
26.2
16.1
17.2
12.4
20.2
14.9
22.3
16.9
14.2
12.8
16.8
15.6
18.6
17.7
21.6
10.7
25.2
12.5
27.8
13.9
18.2
11.1
21.3
13.2
23.7
14.9
15.1
11.4
17.7
13.7
19.8
15.7
12.2
11.7
14.2
14.1
16.0
16.0
19.5
9.8
22.8
11.6
25.2
12.8
16.0
10.2
18.8
12.2
21.0
13.7
13.0
10.4
15.2
12.4
17.2
14.3
10.1
10.1
11.8
11.8
13.7
13.7
17.0
8.7
20.2
10.5
22.4
11.8
13.7
9.1
16.2
11.1
18.0
12.5
10.8
9.1
13.0
11.2
14.6
12.6
8.1
8.1
10.0
10.0
11.8
11.8
14.3
7.7
17.1
9.2
19.0
10.5
11.0
8.1
13.1
9.9
14.7
11.3
9.0
8.1
10.8
9.9
12.3
11.3
7.5
7.5
9.2
9.2
10.7
10.7
l/s
BF
TC
SC
Notes:
1. Gross capacities shown do not include a deduction for evaporator fan motor heat.
2. Contact Carrier for cooling capacities at conditions other than shown in table.
3. Direct interpolation is permissible. Do not extrapolate.
4. SHC is based on 26.7C temperature of air entering the indoor unit. At any other temperature, correct the SHC read from the table of cooling capacities as follows:
Corrected SHC kW = SHC + [1.23 x 10 -3 x (1-BF) x (Cdb-26.7) x l/s] Observe the rule of signs. Above 26.7C, SHC correction will be positive; add it to SHC. Below 26.7C, SHC
correction will be negative; subtract it from SHC.
5. Formula:
Cldb = Cedb - SHCkW
1.23 x 10-3 x (l/s)
Leaving wet bulb = wet bulb temperature corresponding to enthalpy of air leaving coil (hlwb).
hlwb = hewb - TCkW
1.20 x 10-33 x (l/s)
Where hewb is enthalpy of air entering evaporator coil (kJ/kg).
Combination ratings
38EYX
size
FX4CSX
size
Nominal
air flow
l/s
Heating capacity at 7C
Rated capacity
COP
kW
W/W
024-70
036-90
048-90
060-90
024
036
048
060
380
560
730
875
6.83
9.98
13.66
16.73
6.64
10.39
14.48
17.07
3.22
3.18
3.13
2.85
3.63
3.49
3.79
3.39
Notes:
Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling standard: 27C db/19C wb indoor entering air temperature and 35C db air entering outdoor unit.
High-temperature heating standard: 20 db indoor entering air temperature and 7C db/6C wb air entering outdoor unit.
System Design
1. Intended for outdoor installation with free air inlet and outlet.
Outdoor fan external static pressure available is less than
2.5 Pa.
2. Minimum outdoor operating air temperature for cooling mode
without low-ambient operation accessory is 13C.
3. Maximum outdoor operating air temperature for cooling
mode is 52C.
4. Minimum outdoor operating air temperature for heating mode
is -34C.
5. Maximum outdoor operating air temperature for heating
mode is 19C.
6. For reliable operation, unit should be level in all horizontal
planes.
7. Maximum elevation of indoor coil above or below base of
outdoor unit is: indoor coil above = 15 m, indoor coil below
= 45 m. (See items 8 and 9 following.)
Fan motor
speed
75
100
125
024
High
Medium
Low
519
462
415
482
429
386
431
385
340
369
321
-
299
-
036
High
Medium
Low
692
612
511
658
581
494
619
544
472
571
496
439
478
-
048
High
Medium
Low
812
770
713
765
724
671
716
678
630
661
628
579
595
-
060
High
Medium
Low
885
803
671
844
767
647
800
731
624
755
690
-
706
-
Notes:
Fan performance based on wet coil with factory-supplied filter; no internal heaters.
Not recommended for use above 150 Pa external static pressure.
Outdoor temperature, C
Outdoor unit
Humidifier
Fan coil
Air flow
Electronic air
cleaner
Fans
Condenser fan will be direct-drive propeller type,
discharging air upward. Condenser fan motors will be
totally enclosed, 1-phase type with class B insulation and
permanently lubricated bearings. Shafts will be corrosion
resistant. Fan blades will be statically and dynamically
balanced. Condenser fan openings will be equipped with
PVC-coated steel wire safety guards.
Compressor
Compressor will be hermetically sealed. Compressor will
be mounted on rubber vibration isolators.
Condenser coil
Condenser coil will be air-cooled. Coil will be constructed
of aluminium fins mechanically bonded to copper tubes
which are then cleaned, dehydrated, and sealed.
Refrigeration components
Refrigeration circuit components will include liquid line
shutoff valve with sweat connections, suction shutoff valves
with sweat connections, system charge of refrigerant
R-410A, compressor oil, accumulator, and reversing valve.
Operating characteristics
The capacity of the unit will meet or exceed ____ kW at a
suction temperature of ____ C. The power consumption at
full load will not exceed ____ kW. Combination of the unit
and the evaporator or fan coil unit will have a total net
cooling capacity of ____ kW or greater at conditions of
____ l/s entering air temperature at the evaporator at ____
C wet bulb and ____ C dry bulb, and air entering the unit
at ____ C.
Electrical requirements
Nominal unit electrical characteristics will be ____ V, 1 or 3
phase, 50 Hz. The unit will be capable of satisfactory
operation within voltage limits of ____ V to ____ V. Unit
electrical power will be single point connection. Control
circuit will be 24 V.
Special features
Refer to section of this literature identifying accessories and
descriptions for specific features and available
enhancements.