Sie sind auf Seite 1von 20

ANNEXURE-A

GYASPUR DEPOT
CALCULATIONS FOR STORM WATER
DRAINAGE SYSTEM
1.0

CALACULATIONS FOR CARRYING CAPACITY OF MASONRY


DRAINS

1.1

450MM WIDE X 660MM HYDRAULIC DEPTH (NODE 1 TO 4)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.66
0.45+ (2x0.66)

0.297
1.77

0.168

1
x (0.168)2/3 x 1 1/2
0.015
1000

1
x (0.168)2/3 x (0.001) 1/2
0.015

1
x 0.304x 0.0316
0.015

0.641m3/sec.

bxd
b + 2d
1:1000
0.015
450mm
=
660mm

Therefore carrying capacity of drain

Techno Engineering Consultants

DC-2

ANNEXURE-A
q

1.2

=
=

b x d xv
0.45x0.66x0.641

0.190m3/sec

450MM WIDE X 825MM HYDRAULIC DEPTH (NODE 2 TO 3)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.825
0.45+ (2x0.825)

=
2.1

0.177

1
x (0.177)2/3 x 1
0.015
500

1
x (0.177)2/3 x (0.002) 1/2
0.015

1
x 0.315 x 0.0447
0.015

0.939 m3/sec.

bxd
b + 2d
1:500
0.015
450mm
=
825mm
0.371

1/2

Therefore carrying capacity of drain


q

1.3

=
=

b x d xv
0.45x0.825x0.939

0.349m3/sec

450MM WIDE X 1050MM HYDRAULIC DEPTH (NODE 4 TO 5)


By using Mannings formula

Techno Engineering Consultants

DC-3

ANNEXURE-A
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 1.05
0.45+ (2x1.05)

0.473
2.55

0.185

1
x (0.185)2/3 x 1 1/2
0.015
1000

1
x (0.185)2/3 x (0.001) 1/2
0.015

1
x 0.325 x 0.0316
0.015

0.685m3/sec.

bxd
b + 2d
1:1000
0.015
450mm
=
1050mm

Therefore carrying capacity of drain


q

1.4

b x d xv

0.45x1.05x0.685

0.324m3/sec.

600MM WIDE X 1395MM HYDRAULIC DEPTH (NODE 5 TO 8)


By using Mannings formula
V

1 r2/3 s1/2
n

Techno Engineering Consultants

DC-4

ANNEXURE-A
q

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.60 x 1.395
0.60+ (2x1.395)

=
0.837
3.39

0.247

1
x (0.247)2/3 x 1
0.015
500

1
x (0.247)2/3 x (0.002) 1/2
0.015

1
x 0.394 x 0.0447
0.015

1.173m3/sec.

bxd
b + 2d
1:500
0.015
600mm
=
1395mm

1/2

Therefore carrying capacity of drain


q

1.5

b x d xv

0.60x1.395x1.173

0.982m3/sec.

450MM WIDE X 1100MM HYDRAULIC DEPTH (NODE 6 TO 7)


By using Mannings formula
V

1 r2/3 s1/2
n

Techno Engineering Consultants

DC-5

ANNEXURE-A
q

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 1.100
0.45+ (2x1.100)

=
0.495
2.65

0.187

1
x (0.187)2/3 x 1
0.015
500

1
x (0.250)2/3 x (0.002) 1/2
0.015

1
x 0.327 x 0.0447
0.015

0.974m3/sec.

bxd
b + 2d
1:500
0.015
450mm
=
1100mm

1/2

Therefore carrying capacity of drain


q

1.6

b x d xv

0.45x1.1x0.974 =

0.482m3/sec.

600MM WIDE X 1895MM HYDRAULIC DEPTH (NODE 8 TO 11)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :

Techno Engineering Consultants

DC-6

ANNEXURE-A
V
q
r

=
=
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.60 x 1.895
0.60+ (2x1.895)

=
1.137
4.39

0.259

1
x (0.259)2/3 x 1
0.015
500

1
x (0.259)2/3 x (0.002) 1/2
0.015

1
x 0.406 x 0.0447
0.015

1.211m3/sec.

bxd
b + 2d
1:500
0.015
600mm
=
1895mm

1/2

Therefore carrying capacity of drain


q

1.7

b x d xv

0.60x1.895x1.211

1.377m3/sec.

450MM WIDE X 750MM HYDRAULIC DEPTH (NODE 9 TO 10)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=

Velocity in Metres per sec.


Discharge in litres per sec.

Techno Engineering Consultants

DC-7

ANNEXURE-A
r

Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.750
0.45+ (2x0.750)

=
0.3375
1.95

0.173

1
x (0.173)2/3 x 1
0.015
500

1
x (0.173)2/3 x (0.002) 1/2
0.015

1
x 0.311 x 0.0447
0.015

0.926m3/sec.

bxd
b + 2d
1:500
0.015
450mm
=
750mm

1/2

Therefore carrying capacity of drain


q

1.8

b x d xv

0.45x0.75x0.926

0.313m3/sec.

600MM WIDE X 1805MM HYDRAULIC DEPTH (NODE 10 TO 11)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

Slope

Techno Engineering Consultants

bxd
b + 2d
1:500

DC-8

ANNEXURE-A
n
b
d

=
=
=

Mannings Coefficient
Width of drain
Depth of water flow

=
=

0.60 x 1.805
0.60+ (2x1.805)

=
1.083
4.21

0.257

1
x (0.257)2/3 x 1
0.015
500

1
x (0.257)2/3 x (0.002) 1/2
0.015

1
x 0.404 x 0.0447
0.015

1.206m3/sec.

0.015
600mm
=
1805mm

1/2

Therefore carrying capacity of drain


q

1.9

b x d xv

0.60x1.805x1.206

1.306m3/sec.

600MM WIDE X 2355MM HYDRAULIC DEPTH (NODE 11 TO 13)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b

Slope
Mannings Coefficient
Width of drain

=
=
=

Techno Engineering Consultants

=
=
=

bxd
b + 2d
1:500
0.015
600mm

DC-9

ANNEXURE-A
d

Depth of water flow

0.60 x 2.355
0.60+ (2x2.355)

0.266

1
x (0.266)2/3 x 1
0.015
500

1
x (0.266)2/3 x (0.002) 1/2
0.015

1
x 0.414 x 0.0447
0.015

1.233m3/sec.

2355mm

=
1.413
5.31

1/2

Therefore carrying capacity of drain


q

b x d xv

0.60x2.355x1.233

1.742m3/sec.

1.10 750MM WIDE X 2420MM HYDRAULIC DEPTH (NODE 13 TO 16)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=
=

Techno Engineering Consultants

=
=
=

bxd
b + 2d
1:750
0.015
750mm
=
2420mm

DC-10

ANNEXURE-A

0.75 x 2.420
0.75+ (2x2.420)

=
1.815
5.59

0.325

1
x (0.325)2/3 x 1
0.015
750

1
x (0.325)2/3 x (0.0013) 1/2
0.015

1
x 0.472 x 0.0365
0.015

1.150m3/sec.

1/2

Therefore carrying capacity of drain


q

b x d xv

0.75x2.420x1.150

2.087m3/sec.

1.11 450MM WIDE X 890MM HYDRAULIC DEPTH (NODE 14 TO 15)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.890

Techno Engineering Consultants

bxd
b + 2d
1:500
0.015
450mm
=
890mm
0.401

DC-11

ANNEXURE-A
0.45+ (2x0.890)

2.23

0.180

1
x (0.180)2/3 x 1
0.015
500

1
x (0.180)2/3 x (0.002) 1/2
0.015

1
x 0.318 x 0.0447
0.015

0.949m3/sec.

1/2

Therefore carrying capacity of drain


q

b x d xv

0.45x0.89x0.949

0.380m3/sec.

1.12 750MM WIDE X 2595MM HYDRAULIC DEPTH (NODE 16 TO 17)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.75 x 2.595
0.75+ (2x2.595)

=
1.946
5.94

Techno Engineering Consultants

bxd
b + 2d
1:750
0.015
750mm
=
2595mm

DC-12

ANNEXURE-A

0.328

1
x (0.328)2/3 x 1
0.015
750

1
x (0.328)2/3 x (0.0013) 1/2
0.015

1
x 0.475 x 0.0365
0.015

1.157m3/sec.

1/2

Therefore carrying capacity of drain


q

b x d xv

0.75x2.595x1.157

2.252m3/sec.

1.13 750MM WIDE X 2830MM HYDRAULIC DEPTH (NODE 18 TO 20)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.75 x 2.830
0.75+ (2x2.830)

=
2.123
6.41

0.331

Techno Engineering Consultants

bxd
b + 2d
1:750
0.015
750mm
=
2830mm

DC-13

ANNEXURE-A

1
x (0.331)2/3 x 1
0.015
750

1/2

1
x (0.331)2/3 x (0.0013) 1/2
0.015

1
x 0.479 x 0.0365
0.015

1.165m3/sec.

Therefore carrying capacity of drain


q

b x d xv

0.75x2.830x1.165

2.473m3/sec.

1.14 450MM WIDE X 710MM HYDRAULIC DEPTH (NODE 19 TO 20)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.71
0.45+ (2x0.71)

0.320
1.87

0.171

1
x (0.171)2/3 x 1
0.015
500

Techno Engineering Consultants

bxd
b + 2d
1:500
0.015
450mm
=
710mm

1/2

DC-14

ANNEXURE-A

1
x (0.171)2/3 x (0.002) 1/2
0.015

1
x 0.308x 0.0447
0.015

0.918m3/sec.

Therefore carrying capacity of drain


q

=
=

b x d xv
0.45x0.71x0.918

0.293m3/sec

1.15 450MM WIDE X 720MM HYDRAULIC DEPTH (NODE 21 TO 22)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.720
0.45+ (2x0.720)

=
0.324
1.89

0.171

1
x (0.171)2/3 x 1
0.015
500

bxd
b + 2d
1:500
0.015
450mm
=
720mm

1/2

x (0.171)2/3 x (0.002) 1/2

Techno Engineering Consultants

DC-15

ANNEXURE-A
0.015
=

1
x 0.309x 0.0447
0.015

0.920m3/sec.

Therefore carrying capacity of drain


q

=
=

b x d xv
0.45x0.720x0.920

0.298m3/sec

1.16 600MM WIDE X 1580MM HYDRAULIC DEPTH (NODE 22 TO 23)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.60 x 1.580
0.60+ (2x1.580)

=
0.948
3.76

0.252

1
x (0.252)2/3 x 1
0.015
500

1
x (0.252)2/3 x (0.002) 1/2
0.015

Techno Engineering Consultants

bxd
b + 2d
1:500
0.015
600mm
=
1580mm

1/2

DC-16

ANNEXURE-A
=

1
x 0.399x 0.0447
0.015

1.190m3/sec.

Therefore carrying capacity of drain


q

=
=

b x d xv
0.60x1.580x1.190

1.128m3/sec

1.17 600MM WIDE X 2510MM HYDRAULIC DEPTH (NODE 24 TO 25)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.60 x 2.510
0.60+ (2x2.510)

=
1.506
5.62

0.268

1
x (0.268)2/3 x 1
0.015
500

1
x (0.268)2/3 x (0.002) 1/2
0.015

1
x 0.416x 0.0447
0.015

Techno Engineering Consultants

bxd
b + 2d
1:500
0.015
600mm
=
2510mm

1/2

DC-17

ANNEXURE-A

1.239m3/sec.

Therefore carrying capacity of drain


q

=
=

b x d xv
0.60x2.510x1.239

1.866m3/sec

1.18 600MM WIDE X 2970MM HYDRAULIC DEPTH (NODE 26 TO 27)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.60 x 2.970
0.60+ (2x2.970)

=
1.782
6.54

0.272

1
x (0.272)2/3 x 1
0.015
500

1
x (0.272)2/3 x (0.002) 1/2
0.015

1
x 0.420x 0.0447
0.015

1.253m3/sec.

Techno Engineering Consultants

bxd
b + 2d
1:500
0.015
600mm
=
2970mm

1/2

DC-18

ANNEXURE-A

Therefore carrying capacity of drain


q

=
=

b x d xv
0.60x2.970x1.253

2.233m3/sec

1.19 1000MM WIDE X 3120MM HYDRAULIC DEPTH (NODE 27 TO


29)
By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

1.00 x 3.120
1.00 + (2x3.120)

=
3.120
7.24

0.431

1
x (0.431)2/3 x 1 1/2
0.015
1000

1
x (0.431)2/3 x (0.001) 1/2
0.015

1
x 0.571x 0.0316
0.015

1.203m3/sec.

Techno Engineering Consultants

bxd
b + 2d
1:1000
0.015
1000mm
=
3120mm

DC-19

ANNEXURE-A

Therefore carrying capacity of drain


q

=
=

b x d xv
1.00x3.120x1.203

3.753m3/sec

1.20 450MM WIDE X 585MM HYDRAULIC DEPTH (NODE 28 TO 29)


By using Mannings formula
V

1 r2/3 s1/2
n

bxdxv

Where :
V
=
q
=
r
=

Velocity in Metres per sec.


Discharge in litres per sec.
Hydraulic depth in meters

S
n
b
d

=
=
=
=

Slope
Mannings Coefficient
Width of drain
Depth of water flow

=
=
=

0.45 x 0.585
0.45+ (2x0.585)

=
0.263
1.62

0.163

1
x (0.163)2/3 x 1
0.015
500

1
x (0.163)2/3 x (0.002) 1/2
0.015

1
x 0.298x 0.0447
0.015

0.888m3/sec.

bxd
b + 2d
1:500
0.015
450mm
=
585mm

1/2

Therefore carrying capacity of drain

Techno Engineering Consultants

DC-20

ANNEXURE-A

=
=

b x d xv
0.45x0.585x0.888

Techno Engineering Consultants

0.234m3/sec

DC-21