Sie sind auf Seite 1von 138

Main Catalogue 2007 / 2008

Components and Systems

Condor Pressure Control GmbH


Warendorfer Strae 47 51
D 59320 Ennigerloh
Phone :+49 (0) 25 87 / 89-0
Telefax: +49 (0) 25 87 / 89-140
e-Mail: info@condor-cpc.com
http:// www.condor-cpc.com

Page 0.02

www.condor-cpc.com

The Company

It all started more than 100 years ago. In 1893


August Frede founded a company which
manufactured

machinery

and

equipment

primarily for agricultural purposes. Above all,


this included centrifuges and pumps. Tradition
has it that the first, or rather one of the first
milking machines ever made was designed and
manufactured by Condor

In the Thirties - at which time the company was


christened Condor - due to it's intensive activity in
the field of pump technology, the company was
granted a patent which is still relevant up to the
present

day

for

diaphragm

based

pressure

switches manufactured all over the world. That laid


the foundation in the field of electronic engineering;
the era of Condor switchgear had begun

Within the company, more and more added


value is generated by customized individual
solutions based on electronic components.
Electrical and electronic components as well as
individually taylored controls of the highest
quality make up a perfect package.

www.condor-cpc.com

Page 0.03

Page 0.04

www.condor-cpc.com

Table of Contents

Page

General
The Company
ISO Certificate
Table of contents
Index

Electronic Components
Electronic pressure transducer EDI
Electronic pressure sensor EDS
Electronic pressure control EDR
Electronic pressure control EDRA
Staging and sequencing control GLW 4
Universal test instrument VARIOTEST
Phase-sequence indicator ROTATEST
Test device for residual current circuit
breakers DELTATEST
Adjustable sensor simulator CSG420
Multifunction timer relay FMF
Multifunction timer relay IMF

Pressure switches general


Setting reference pressure switches
Pressure switches single phase
Pressure switches 3-phase
Control pressure switches
Type code
Type code control pressure switch MDR-F
Media resistance

Pressure switches
Single phase
Pressure switch MDR 1
Pressure switch MDR 11
Pressure switch MDR 2
Pressure switch MDR 21
3-phase
Pressure switch MDR 3
Pressure switch MDR 4
Pressure switch MDR 5

Control pressure switches


Control pressure switch MDR F
Control pressure switch MDR 43
Control pressure switch MDR 53
Control pressure switch FF 142
Control pressure switch PS 1

Level controls
Level control technology
Float switches PSN
Electronic pump control ENP
Electronic level control ENR
Electronic level control relay HRH-2
Stainless steel level sensor ENS

0.03
0.04
0.05
0.06

1.01
1.02
1.03
1.04
1.06
1.08
1.11
1.12
1.13
1.14
1.15
1.18

Manual motor starters


Manual motor starters OKE2 / MKE2
Manual motor starters TFE2 / TFA2
Manual motor starters OKN
Star-delta-starter C-SDU

Condor Pressure Control GmbH


Your partners
Headquarters and Subsidiaries
Representatives Europe
Representatives worldwide
Terms of delivery

Subsidiaries Condor-Werke
Condor Systems GmbH
Scharco Elektronik GmbH
Condor USA, Inc.

Page
6.01
6.02
6.08
6.10
6.13

7.01
7.02
7.03
7.04
7.06
7.07

8.01
8.03
8.04
8.05

2.01
2.02
2.04
2.05
2.06
2.08
2.10
2.11

3.01
3.02
3.05
3.08
3.11
3.14
3.21
3.26

4.01
4.02
4.11
4.13
4.16
4.20

5.01
5.02
5.06
5.10
5.12
5.14
5.16

www.condor-cpc.com

Page 0.05

A
A IP 55
AEV 1 S
AEV 2 ..
AEV 2 ..
AEV 3 ..
AEV 4 ..
AEV 5 ..
AS
AZ

Moulded plastic enclosure IP


55
Unloader valve for difficult
motor starting condition
Unloader valve for difficult
motor starting condition
Unloader valve for difficult
motor starting condition
Unloader valve for difficult
motor starting condition
Unloader valve for difficult
motor starting condition
Unloader valve for difficult
motor starting condition
Shunt release
Supplementary set for
enclosure

6.05, 6.08
3.03, 3.06
3.09
3.12
3.17

H2
H21
H21-EA

3.23

H2-EA

3.27

H3
H3-B ..

6.05
6.05

Moulded plastic enclosure


Weight for float switches

6.05
5.07

Moulded plastic enclosure


Star/Delta Starter
Adjustable sensor simulator

6.05
6.13
1.14

RCCB Tester

1.13

D
DELTATEST

E
E IP 54
EDI
EDR
EDRA
EDS
ENP
ENR
ENS
EV 1 S
EV 2 ..
EV 2 ..
EV 3 ..
EV 4 ..
EV 5 ..

Frontplate with mounting


support
Electronic pressure
transducer
Electronic pressure control
Electronic pressure control
with digital display
Electronic pressure sensor
Electronic dual pump control
Electronic level control
Stainless steel level sensor
Unloader valve
Unloader valve
Unloader valve
Unloader valve
Unloader valve
Unloader valve

1.03
5.10
5.12
5.16
3.03, 3.06
3.09
3.12
3.17
3.23
3.27

Control pressure switch


Control pressure switch
Multifunction timer relay

4.16
4.17
1.15

Enclosure in die-cast
aluminium
Electronic staging and
sequencing control
Electronic staging and
sequencing control without
accessories
Electronic staging and
sequencing control with
accessories

6.05

1.02
1.04
1.06

G
G IP 65
GLW 4
GLW 4-S

GLW 4-S
kompl.

H43
H5
H5-K
Haube
MDR1+
Hi
HRH-2

Page 0.06

enclosure H

www.condor-cpc.com

4.18
4.18
4.18
3.03
3.03

6.05, 6.08
5.14

Weight for float switch


Multifunction timer relay

5.07
1.18

Cable holder for float


switches

5.07

Control pressure switch


Pressure switch
Pressure switch
Pressure switch
Pressure switch
Pressure switch
Pressure switch
Pressure switch
Pressure switch
Control pressure switch
Pressure switch
Control pressure switch
Pressure switch
Differential adjustment
MDR 1 / MDR 11
Throttle as of 32 bar
Throttle up to 32 bar
Cover MDR-F

4.02
3.02
3.05
3.08
3.11
3.14
3.21
3.21
3.22
4.11
3.26
4.13
3.26
3.03, 3.06

Cover MDR-F for reset switch

4.08

Cable glands MDR-F


Reset push-button
Manual motor starter with
thermal and magnetic
releases
Mounting support MDR 3

4.08
4.08
6.02

3.09
3.12
3.12
3.09
3.17
3.16
3.17
3.16
3.23
3.23
3.23
4.12
3.27, 4.14
3.27
3.03

1.08
1.08

1.08

I
IG-PS
IMF

K
K-PS

M
MDR - F ..
MDR 1
MDR 11
MDR 2
MDR 21
MDR 3
MDR 4 S
MDR 4 SD
MDR 4 SU
MDR 43
MDR 5
MDR 53
MDR 5-K
MDR-1 + Diff.
MDR-F D+32
MDR-F D-32
MDR-F
Haube
MDR-F
Haube R
MDR-F M20
MDR-F RT-1
MKE2

H
H

Gauge fitting
Blanking plug
Console
Cover MDR 1
Cover MDR 1 with ON- and
OFF-switch
Cover MDR 2
Cover MDR 21
Cover MDR 21 with ON- and
OFF-switch
Cover MDR 2 with ON- and
OFF-switch
Cover MDR 3
Hourmeter kit and cover
MDR 3
Cover MDR 3 with ON- and
OFF-switch
Hourmeter kit and cover EA
MDR 3
Cover MDR 4
Cover for MDR 4 SD,
transparent
Cover MDR 4 with ON- and
OFF-switch
Cover MDR 43, transparent
Cover MDR 5, MDR 53
Cover MDR 5 with ON- and
OFF-switch
Supplementary set cover
MDR 1
Auxiliary contact
Level control relay

6.05

F
FF 142 .
FFg 142 .
FMF

H4
H4 SD
H4 S-EA

C
C IP 55
C-SDU
CSG420

H3-EA
H3-EA-B ..

B
B IP 55
BG-PS

H 124-114
H 124-88
H 124g-127
H1
H1-EA

6.11

MW 3

4.08
4.08
4.08

3.17

Index
MW 4
MW 5

Mounting support MDR 4,


MDR 43
Mounting support MDR 5,
MDR 53

3.23, 4.12

Phase-sequence indicator
Undervolage release

1.12
3.17

Contact block
Contact block with lock
mechanism
Thermal overlaod relay

3.17
3.17

Immersion electrode
Protective device for motors
with thermocontacts
Protective device for motors
with thermocontacts

5.14
6.08

Undervoltage release

6.05

Padlock blockade device

6.05

VARIOTEST

Acoustic universal test


instrument

1.11

Cable grommet MDR 1


Cable grommet MDR 11,
MDR 21, MDR 3
Cable grommet MDR 2, MDR
4, MDR 43
Cable grommet MDR 5,
MDR 53

3.03
3.06, 3.12,
3.17
3.09, 3.23,
4.12
3.27, 4.14

3.27, 4.14

S
SK 3
SK 3-S

N
NAK

ROTATEST
RU ..

Emergency-OFF-device IP 54 6.05
SK R3 / ..

3.17

O
OKE2
OKN

Manual motor starter with


thermal releases
Manual motor starter with
thermal releases

6.02

6.10

TEL-..
TFA 2
TFE 2

P
PG .. -1
PG .. 11/21
PG .. 2/4/43
PG .. 3
PG .. 5/53
PS 1
PSN-..
PSN-.. +ST
PSN-O DB
PSN-X SP

Cable glands MDR 1


Cable glands MDR 11, MDR
21
Cable glands MDR 2, MDR 4,
MDR 43
Cable glands MDR 3
Cable glands MDR 5, MDR
53
Control pressure switch
Float switches
Float switches with plug
Float switch, special versions
Float switch, special versions

3.03
3.06, 3.12

4.20
5.07
5.07
5.07
5.07

Thermal overload relay


Shunt release
Ermeto-connector
Ermeto-connector

3.27
3.17
4.18
4.18

W
WN
WN .. 11/21/3
WN .. 2/4/43

R
R5 ..
RA ..
R-AD 10 ..
R-AD 6

U
US

3.09, 3.22,
4.12
3.17
3.27, 4.14

6.08

WN .. 5/53

www.condor-cpc.com

Page 0.07

Page 0.08

www.condor-cpc.com

Electronic Components

Electronic pressure transducers,


sensors and controls
Page
1.02

EDI

Electronic pressure transducer


Pressure range up to 16 bar
Output signal 4 - 20 mA

EDS

Electronic pressure sensor


Pressure range up to 16 bar
Output signal 4 - 20 mA

1.03

EDR

Electronic pressure control


Pressure range up to 16 bar
Output signal 0 - 10 V

1.04

EDRA

Electronic pressure control


with digital display
Pressure range up to 16 bar
Relay output

1.06

GLW 4

Electronic staging and sequencing


control
max. cut-out pressure 16 bar
for 4 compressors
Display for programming and indication

1.08

Test devices
Page
1.11

VARIOTEST

The Condor-VARIOTEST
is a universal test instrument
featuring acoustic signals for:

ROTATEST

The Condor-ROTATEST
is a Phase-sequence
indicator with optical display

1.12

DELTATEST

The Condor-DELTATEST
is a test device for residual
current circuit breakers

1.13

CSG420

The Condor-CSG420
is an adjustable sensor
simulator 4-20 mA

1.14

Multifunction timer relay


FMF

Multifunction timer relay in compact


industrial standard casing
8 switchable time ranges
universal current

IMF

Multifunction timer relay featuring


installation type dimensions
4 switchable time ranges
universal current

Page
1.15

1.18

www.condor-cpc.com

Page 1.01

Electronic pressure transducers EDI

Pressure transducers EDI


Pressure range up to 16 bar
for panel board mounting
Output signal: 4 - 20 mA
Electronic pressure transducer with integrated relative pressure sensor for
panel board mounting, quick-connect for pneumatic tube, analogue output 4
to 20 mA and operating voltage 12...30 V-DC.
Function: the device converts the pressure applied to the sensor into a
proportional DC- current (2 - wire technology).

Type overview EDI


Order reference

Measuring range
(bar)*

Max. perm.
pressure (bar)

Max. inaccuracy
at 25 C

Operating voltage
UB (V-DC)

Part No.

0 - 10
0 - 16

25
25

2.5 %
2.5 %

12...30
12...30

3700080
3700090

EDI 10
EDI 16

*4 mA = 0 bar / 20 mA = measuring range end value

Technical Data EDI


Technical operating data

Output signal

Permissible operating voltage range

10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0.1%

Clearance and creepage distances


Working position

Enclosure
-20 C up to
+ 60 C
10% up to
90%
-40 C up to
+ 80 C
VDE 0110

max. 1 VA

Material
Mounting
Enclosure-protection
Protection against shock
Terminals
Cross section
Weight

Pressure connection
Quick-connect
suitable pneumatic tube

6 x 1 mm
Festo PAN

Dimensions- / Circuit Diagrams EDI

Page 1.02

www.condor-cpc.com

4 - 20 mA

100%

any position

Power consumption

Analogue output

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

IP 40
acc. VBG 4
Cage clamps
2,5 mm
85 g

Electronic pressure sensor EDS

Pressure sensor EDS


Pressure range up to 16 bar
Output signal: 4 - 20 mA
Electronic pressure control with relative pressure sensor for direct installation
either on or within a device, G " connection, analogue output 4 20 mA and
operating voltage supply 11 30 V DC. Electrical connection is effected in a
straightforward and service-friendly manner - via a DIN 43650-A plug whereby a
Degree of Protection IP 65 is realized.
Function: the device converts the pressure applied to the sensor into a
proportional DC current (2 - wire technology).

Type overview EDS


Order reference

Measuring range
(bar)*

Max. perm.
pressure (bar)

Max. inaccuracy
at 25 C

Operating voltage
UB (V-DC)

Part No.

0- 6
0 - 10
0 - 16

32
32
32

2.5 %
2.5 %
2.5 %

11...30
11...30
11...30

1090210008
1090210007
1090210001

EDS 6
EDS 10
EDS 16

*4 mA = 0 bar / 20 mA = measuring range end value

Accessories EDS
Order
reference

Description

EDS-ST

Weight
in g

Part No.

110

1090210002

connection socket EDS, DIN 43650-A

Technical Data EDS


Technical operating data

Pressure connection

Permissible operating voltage range

10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0.1 %

Clearance and creepage distances


Working position
Power consumption

Connection
Outer thread

G 1/4

100 %

Output signal
Analogue output

15C up to
+ 80C
10 % up to
90 %
-40 C up to
+ 80 C
VDE 0110
any position
max. 1 VA

4 - 20 mA

Enclosure
Enclosure-protection

max. IP 65

Terminals

Quick connects

Cross section

Quick connects
4,5 mm
150 g

Weight

Dimensions- / Circuit Diagrams EDS

www.condor-cpc.com

Page 1.03

Electronic pressure control EDR

Electronic pressure control EDR


Pressure range up to 16 bar
For panel board mounting
Relay output
Output signal: 0 10 V
Electronic pressure switch with integrated relative pressure sensor for panel
board mounting, quick-connect for pneumatic tube, two fixed adjustable
switching points, relay output (isolated SPDT), analogue voltage output 010 V via jack plug (look at accessories) and isolating transformer acc. to
VDE 0550.
Function: The device evaluates the applied pressure. On exceeding an
upper threshold the relay is deactivated; when falling below a lower
threshold the relay is activated again. Both thresholds are adjustable.

Type overview EDR


Order reference

Measuring range
(bar)*

Max. perm.
pressure (bar)

Max. inaccuracy
bei 25 C

Operating voltage
UB (V-DC)

Part No.

0,2 2
1 - 16

25
25

2.5 %
2.5 %

230
230

3700010
3700030

EDR 2
EDR 16

*adjustable in 0.1 bar steps


0 V = 0 bar / 10 V = measuring range end value

Accessories EDR
Order
reference
KL-S

Description

Weight
in g

Part No.

15

3709400

Jack 2.5 mm for analogue output connection (cable length 5 m)

Technical Data EDR


Technical operating data

Enclosure

Permissible operating voltage range

10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0.1 %

Clearance and creepage distances


Working position

100 %
-20C up to
+60C
10 % up to 90
%
-40C up to
80C
VDE 0110
any position

Power consumption

Material

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Enclosure-protection
Protection against shock
Terminals

IP 40
acc. VBG 4
Cage clamps

Cross section

2.5 mm

Weight

135 g

Male jack plug


Jack 2,5 mm

2.5 mm

max. 1 VA

Power section
Pressure connection
Quick-connect
suitable pneumatic tube e.g.

6 x 1 mm
Festo PAN

Output signal
Analogue voltage signal
max. 5 mA short-circuit proof

Page 1.04

www.condor-cpc.com

0 - 10 V

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
per contact
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles

250 V-AC
6 A-AC
1.500 VA (AC)
50 W (DC)
7
approx. 1 x 10
approx. 2 x 10

Electronic pressure controls EDR

Dimensions EDR

Circuit Diagram EDR

www.condor-cpc.com

Page 1.05

Electronic pressure controls EDRA

Pressure controls EDRA


Pressure range up to 16 bar
For panel board mounting
Relay output
Digital display
Electronic pressure switch with integrated relative pressure sensor for panel
board mounting, quick-connect for pneumatic tube, digital display for mains
pressure indication and threshold programming (two switching points), relay
output (isolated SPDT) and isolating transformer acc. to VDE 0550.
Function: The device evaluates the applied pressure to the sensor. On
exceeding an upper threshold the relay is deactivated; when falling below a
lower threshold the relay is activated again. Both thresholds also are
adjustable without medium. The on/off thresholds can be programmed via
the display during operation - the actual pressure status is shown on the
display.

Type overview EDRA


Order reference

Measuring range
(bar)*

Max. perm.
pressure (bar)

Max. inaccuracy
at 25 C

Operating voltage
UB (V-DC)

Part No.

1 - 16

25

2.5 %

230

3700060

EDRA 16
*adjustable in 0.1 bar steps

Technical Data EDRA


Technical operating data

Enclosure

Permissible operating voltage range

10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0.1 %

Clearance and creepage distances


Working position

100 %
-20C up to
+60C
10 % up to 90
%
-40C up to
80C
VDE 0110

Material

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Enclosure-protection
Protection against shock
Terminals

IP 40
acc. VBG 4
Cage clamps

Cross section

2.5 mm

Weight

255 g

any position

Power section
Power consumption

max. 1 VA

Pressure connection
Quick-connect
suitable pneumatic tube e.g.

Page 1.06

www.condor-cpc.com

6 x 1 mm
Festo PAN

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
per contact
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles

250 V-AC
6 A-AC
1.500 VA (AC)
50 W (DC)
7
approx. 1 x 10
approx. 2 x 10

Electronic pressure controls EDRA

Dimensions EDRA

Circuit Diagram EDRA

www.condor-cpc.com

Page 1.07

Electronic staging and sequencing control GLW 4

Staging and Sequencing Control for


Compressors
More and more companies today need an
economic operating air pressure system.
Thereby, several compressors are often connected
to each other. Since 1995 Condor GLW controls
have been used to monitor up to 4 compressors in
primary load set up. The GLW 4 evaluates the mains
pressure and rotates the connected compressors on
a time-dependent basis. If desired, an internal timer
is available e.g. shift work applications.

Following functions can be activated:


Internal pressure transducer 0 to 16 bar
Connection of an external pressure transducer, two-wire 4 to 20mA
Programmable internal time switch (controls up to 6 profiles)
Programmable primary load and load changeover functions, allowing for the primary
load compressor to operate without taking part in the rotation process. Only the load
changeover compressors are rotated.
Programmable ball valve control with max. 3 compressors
Direct switchover after the load changeover time has elapsed.
Four digital inputs (e.g. for hourmeter )
Input: bridge time switch
Input: remote release
Parameter password protection
Units reversible bar/psi

Type overview GLW 4


Order
reference

Description

Part No.

GLW 4

GLW 4 without wiring, enclosure

237761

GLW 4-S

GLW 4 in pre-wired plastic enclosure, (dimensions: 420x300


x170mm), DIN-Rail mounting, internal terminal blocks and wiring
diagram.

291534

GLW 4-S
complete

GLW 4 in pre-wired plastic enclosure, (dimensions: 420x300


x170mm), DIN-Rail mounting, internal terminal blocks and wiring
diagram.
Additionally wired for 4 compressors: isolator, rotary switch bridge
timer, rotary switch compressor 1 - 4, indicator lamps for voltage
supply and compressors 1 4.

291527

Additional styles on demand!

Page 1.08

www.condor-cpc.com

Electronic staging and sequencing control GLW 4


Wiring diagram GLW 4-S (completely assembled)

Housing GLW 4 Terminal connections

A1
A2

I11 I21 I31 I41 I51 I61


I12 I22 I32 I42 I52/62 14

12
11

24
22

21
34

32
31

44
42

41
54

52
51

p+
p-

OK

A1 / A2
I 11 to I 42

=
=

I 51
I 61
11 to 44

=
=
=

51, 52, 54

p+ / p-

COM

Mains voltage supply 90 265 V AC; 50/60 Hz

4 digital Inputs, 250V AC1, e. g. operating


hours
External release input, 250V AC1
Bridge time switch input, 250V AC 1
Isolated SPDT outputs for max. 4 compressors
230V AC, max. 5A AC1
Isolated alarm relay 230V AC, max. 5A AC1

GLW 4
COM

Control & Solution

CE

External analogue connection 4 - 20mA


Two wire Ub= 18-21V DC
V 24-Interface for PC programming

integrierter Druckluftanschluss
Integrated quick-connect

A1; A2; I51 and I52/62 must be connected to enable basic functionality.
No special programming knowledge is required.

Dimensions GLW 4 / GLW 4-S

GLW 4

GLW 4-S
www.condor-cpc.com

Page 1.09

Electronic staging and sequencing control GLW 4

Technical Data
Technical operating data
Permissible operating voltage range
Operating voltage influence
at 10% operating voltage fluctuation
Duty factor
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature
Clearance and creepage distances

Digital in- and outputs


90 265 V AC
50 60 Hz
<0.1%
100%
-20 C up to
+60 C
10% up to
90%
-40 C up to
+80 C
VDE 0110

4 Relay outputs
isolated SPDT's
1 Alarm relay
isolated SPDT
Internal buzzer

230V-AC; 5 A
(AC1)
230V-AC; 5 A
(AC1)
typical
70dBA)
AC 1 (I11/12
I41/42)
External
release signal
Input 250VAC1 (I61/62)

4 digital inputs 250V


Input 250V-AC1 (I51/52)
Bridge time switch

Analogue Interface
Working position

Any position

Power consumption
Control

10 VA

Input analogue pressure transducer UB


4 - 20 mA, 2 wire
Integrated pressure transducer
With quick connect

Power section
Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
per contact
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles

18 21V-DC
016 bar

Enclosure
250 V-AC
6 A-AC
1.100 VA (AC)
50 W (DC)
approx. 1 x
7
10
approx. 2 x
5
10

Material

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Enclosure-protection
Protection against shock
Terminals

IP 40
acc. VBG 4
Cage clamps

Cross section

2.5 mm

Weight

520 g

Measuring accuracy and Requirements


Input external pressure transducer

2% of end
value

Internal pressure transducer

2% of end
value
89 / 336 /
EWG
73 / 23 / EW

EM-Directive
Low Voltage Directive

Page 1.10

www.condor-cpc.com

Pressure connection
Pneumatic tube diameter
suitable pneumatic tube e.g.

6 x 1 mm
Festo PAN

VARIOTEST
The Condor-Variotest is a universal test
instrument featuring acoustic signals
for:
Continuity and/or resistance
testing up to 20 k
Direct and alternating voltage
checking up to 500 V
Polarity test for D.C. from 6 V
to 500 V
Phase checking
(outer conductor) Mp conductor
and protective conductor
Checking function of RCCB's
with IN max. 30 mA
Semi-conductor testing

The Condor-VARIOTEST
- is protected against external
voltages up to 500 V and limits
the current input to max. 4 mA.
Destruction as a result of
incorrect handling is practically
impossible.
- distinguishes between D.C.
and A.C. voltages or a
resistance value by sound pitch
and
frequency
change
respectively.
- is equipped with an ON-OFF
switch.
- is supplied with the battery
inserted and is ready for
immediate use.
- Measuring probes and leads
acc. to IEC 1010 Part 2-031.

Type overview
Order reference

Packing
(units)

Weight
in g

Part No.

115

3066100

VARIOTEST

Technical Data Variotest


Technical operating data
Test range

Audio frequency

Leads

Measuring probes

Protection

Clearance and creepage distances

Power supply
Included in the scope of supply

Dimensions
0 20 k
0 500 V
up to 20 kHz

80 cm

crush proof

protective double
insulation
acc. to VDE 0110

Battery 9V
Block IEC 6 F22

www.condor-cpc.com

Page 1.11

ROTATEST
The Condor-Rotatest indicates the phase sequence in a three-phase
mains circuit and thus the direction of rotation for electromotive
appliances.

The additional phase monitoring glow lamps also indicate whether all
the outer conductors are live and ensure that the neutral and outer
conductors have not been interchanged.

VDE 0100 stipulates:


Three-phase sockets shall be connected in such a manner that a
rotation field to the right is reached when looking at the front of the
sockets clockwise.

Measuring probes and leads acc. to IEC 1010 Part 2-031.

Type overview
Order reference

Packing
(units)

Weight
in g

Part No.

195

3066300

ROTATEST

Technical Data
Technical operating data
Voltage range

Dimensions

250 V
up to max. 650 V

Current consumption
at 380 V

5 mA

Duty factor ED
at 380 V

100 %

Leads

80 cm

Measuring probes

Clearance and creepage distances

Page 1.12

crush proof

acc. to VDE 0110

www.condor-cpc.com

DELTATEST
The Condor-Deltatest is used for testing residual current circuit
breakers and electrical installations which are monitored by them.
It "simulates" at any point of the installation (much easier is a socket
outlet) a fault current with an effective duration (< 200 ms) according
to Specifications and which value is set by a selector switch to the
rated fault current of the previously connected RCCB (10, 30, 100, 300
and 500 mA).

The Condor-Deltatest is not a measuring instrument in the sense of


VDE 0413 and therefore may not be used for measurements acc. to
VDE 0100 Part 600.

VDE 0664 Part 1 stipulates:


That the breaking delay time of an RCCB shall not exceed 0.2
seconds for A.C. rated operating fault currents and at 1.4 times the
rated operating fault current of pulsating D.C. currents.
Measuring probes and leads acc. to IEC 1010 Part 2-031.

Type overview
Order reference

Packing
(units)

Weight
in g

Part No.

115

3066400

DELTATEST

Technical Data
Technical operating data
Voltage range

Rated operating fault currents


(adjustable)
Testing time

Test cycle

Leads

Measuring probes

Protection

Clearance and creepage distances

Dimensions
250 V ~

0.01 A / 0.03 A /
0.1 A / 0.3 A /
0.5 A
< 200 ms

approx. 5 s

80 cm

crush proof

protective double
insulation
acc. to VDE 0110

www.condor-cpc.com

Page 1.13

CSG420
The sensor simulator Condor-CSG420 is used to simulate a level
sensor (4 20 mA) on an electronic control unit

Functions:
Adjustable DC current 4 20 mA
Measurement of the terminal voltage

Features
LCD Display
Functions selector switch
Potentiometer for current adjustment

Applications
Commissioning
Repairs
Trouble shooting

Type overview
Order reference

Packing
(units)

Weight
in g

Part No.

220

249634

CSG420

Technical Data
Technical operating data
Adjustable current range

Terminal voltage measuring range

Display accuracy

8.5 V up to 32 V

2 % end value 1
Digit

Leads

80 cm

Clearance and creepage distances

Power supply
Included in the scope of supply

Page 1.14

Dimensions
3.5 mA up to
25.5 mA

acc. to VDE 0110

Battery 9V
Block IEC 6 F22

www.condor-cpc.com

Multifunction timer relay FMF


Multifunction timer relay FMF

Multifunction relay in compact industrial standard casing


8 selectable time ranges
Universal current
2 SPDT's
Remote-control terminal
Voltage activation

The multifunction timer relay FMF is specifically


prevents destruction of the devices due to faulty
designed for rough industrial environments. All
wiring.
inputs and outputs are both interference free and
Adjustable functions:
non-destructive at voltage surges of up to 2 kV.
Contact activation may be carried out not only by
delay on make
conventional means such as an isolated contact
delay on break
(between A1 and B1) but also by applying the
on-delay single shot
operating voltage to B1. This helps to reduce
flashing
wiring and contact requirements of the control and
Remote control:
A remote control can be realised with 2 wires connected to the terminals Z1 / Z2 and a 100 k
potentiometer, whereby the FMF potentiometer must be set to 0.

Type overview FMF


Order reference
FMF

Time

Operating voltage UB
(V-AC/DC)

SPDT's

Part No.

0.1 s ca. 7 h

22,5 240

230403

Technical Data FMF


Output contacts

Technical operating data


Permissible operating voltage range

10%

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0.5 %

Clearance and creepage distances


Working position
Power consumption

100%
- 20C up to
+60C
10% up to 90%
- 40C up to
+80C
VDE 0110

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
1 change over, 2-change -over
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles
Resistance of remote-control
Standard

250 V-AC
6 A-AC
1.500 VA (AC)

50 W (DC)
approx. 1 x
7
10
approx. 2 x
5
10
100 k

any position
max. 2 VA

www.condor-cpc.com

Page 1.15

Multifunction timer relay FMF


Enclosure Data
Material

General data

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Enclosure-protection
Protection against shock
Terminals

IP 40
acc. VBG 4

Tolerance range

10%

Repeatability

0.5 %

Temperature range

approx. 0,2 %
/ C
< 100 ms

Recovery time

Screw clamps

Time ranges
Cross section

2 x 1.5 mm

Weight

200 g

Dimensions- / Circuit Diagram FMF

Page 1.16

www.condor-cpc.com

Initial value
0,05 s
0,2 s
1,6 s
12.5 s
5s
20 s
160 s (approx. 2.7 min.)
1250 s (approx. 21 min.)

End value
1s
4s
32 s
250 s
100 s
400s
3200 s (approx. 53 min.)
25000 s (approx. 417 min.)

Multifunction timer relay FMF

Delay on make

Operating voltage UB

Delay on break

Operating voltage UB
Activation B1
Output

Output

On delay single shot

On delay single shot

Operating voltage UB

Operating voltage UB

A1 on B1

Activation B1

Output

Output

Flasher interval start

Flasher impulse start

Operating voltage UB

Operating voltage UB

B1 open

A1 on B1

Output

Output

www.condor-cpc.com

Page 1.17

Multifunction timer relay IMF


Multifunction timer relay IMF

Multifunction relay featuring installation type dimensions


4 selectable time ranges
Universal current
1 SPDT
Contact activation

The multifunction timer relay IMF is specifically


designed for rough industrial environments. All
inputs and outputs are both interference free and
non-destructive at voltage surges of up to 2.000
V. Contact activation may be carried out not only
by conventional means such as a voltage-free
contact (between A1 and B1), but also by applying
the operating voltage to B1. This helps to reduce
wiring and contact requirements of the control and

prevents destruction of the devices due to faulty


wiring.
Adjustable functions:
delay on make
delay on break
on-delay single shot
flashing

Type overview IMF


Order reference
FMF

Time

Operating voltage UB
(V-AC/DC)

SPDT

Part No.

0.6 s 60 min

13.5 240

230410

Technical Data IMF


Technical operating data

Output contacts

Permissible operating voltage range

10%

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0.5 %

Clearance and creepage distances


Working position
Power consumption

Page 1.18

www.condor-cpc.com

100%
- 20C up to
+60C
10% up to 90%
- 40C up to
+80C
VDE 0110
any position
ca. 2 VA

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
1 change over, 2-change -over
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max. load)
Cycles

250 V-AC
6 A-AC
1.500 VA (AC)

50 W (DC)
approx. 1 x
7
10
approx. 2 x
5
10

Multifunction timer relay IMF

Enclosure data
Material
Mounting

General data

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Enclosure-protection
Protection against shock
Terminals

IP 40
acc. VBG 4

Tolerance range

10%

Repeatability

0.5 %

Temperature range

ca. 0.2 % / C

Recovery time

< 100 ms

Screw clamps

Time ranges
Cross-section

2.5 mm

Weight

75 g

Initial value
0.6 s
6s
0.6 min
6 min

End value
6s
60 s
6 min
60 min

Dimensions- / Circuit Diagram IMF

www.condor-cpc.com

Page 1.19

Multifunction timer relay IMF


Delay on make

Operating voltage UB

Delay on break

Operating voltage UB
Activation B1
Output

Output

On delay single shot

On delay single shot

Operating voltage UB

Operating voltage UB

A1 on B1

Activation B1

Output

Output

Flasher interval start

Flasher impulse start

Operating voltage UB

Operating voltage UB

B1 open

A1 on B1

Output

Output

Page 1.20

www.condor-cpc.com

Pressure switches, General

Overview

Setting reference
A short overview regarding pressure and pressure
differential settings of a pressure switch

Page
2.02

High performance pressure switches for AC


currents
Technical data synoptic tables which enable quick
selection of a required pressure switch

2.04

High performance pressure switches for


3-phase currents
Technical data synoptic tables which enable quick
selection of a required pressure switch

2.05

Control pressure switches


Technical data synoptic tables which enable quick
selection of a required control pressure switch

2.06

Type code
For high performance pressure switches and
control pressure switch MDR 43 and MDR 53
For decoding match codes of the different
pressure switch types and accessories

2.08

Type code for control pressure switch MDR-F


For decoding match codes of the different
pressure switch types and accessories

2.10

Media resistance tables


For selecting a suitable pressure switch for a
given media

2.11

www.condor-cpc.com

Page 2.01

Pressure switch setting references


General
Pressure switches
Pressure switches are mainly used to switch pump and compressor motors on and off depending on the
pressure so that the pressure of a given media within a tank does not exceed an upper or fall below a lower
value. The upper pressure value by which e.g. a pressure switch breaks an electric circuit (NC function) is
called the cut-out pressure. The lower pressure value by which the pressure switch makes an electric circuit
is called the cut-in pressure. Both cut-out and cut-in pressures within a given range can be set on the
pressure switch. The reversed switching function by which the upper setting point makes an electric circuit
and the of a lower setting point breaks the electric circuit is called NO function. The pressure switch related
difference between cut-in and cut-out pressures is called hysteresis. Every pressure switch allows the natural
hysteresis to be increased by a differential adjustment. An easy two-point control with a pressure switch is
thus feasible.
Control pressure switches
Control pressure switches represent a special group within pressure switches. These devices are especially
suitable for monitoring and controlling purposes. Depending on the model, SPDT's with or without goldflashed contacts e.g. for PLC applications or isolated NO and NC contacts are available. Depending on the
pressure switch type, loads with a max. power consumption of 1.1 kW can be started directly.
Unloader valves- (EV) and delayed unloader valves (AEV)
Within the range of compressor technology, unloader valves are very often used. Unloader valves allow air
within the feed line of the pressure tank to be bled off enabling pressure less start of the motor when the
pressure switch switches off the motor, extending the life cycle of the motor. The delayed unloader valve has
the same function and additionally supports the motor when starting in that it remains open until a certain
pressure (approx. 2 bars) is reached. In contrast to the unloader valve, the delayed unloader valve is always
open and has delayed closing properties.
Pressure switch settings
Before any changes are carried out on a pressure switch it must be ensured that it is completely voltage free.
However, all settings are to be carried out under pressure. Switching points are always to be compared with
pressure readings of a pressure gauge. Eventually existing pressure scales on some devices serve
orientation purposes only.
When the main pressure spring is adjusted, the cut-in and cut-out value of all pressure switches change
proportionally, i.e. the differential between these values always remain the same. If the range between cut-in
and cut-out value is to be increased, the differential pressure screw must be used.
When carrying out a differential pressure adjustment on the pressure switch types MDR 1, MDR 11, MDR 2
und MDR 21 the cut-out pressure value changes, the cut-in pressure value remains constant. (Notice: As a
standard, the MDR 1 / MDR 11 are delivered without differential adjustments, however, they available as an
accessory).
In contrast and regarding all other pressure switch types, the cut-in pressure value changes, the cut-out
pressure value remains constant.
In the pressure diagram, each pair of cut-in and cut-values are represented by a point. If the point is within
the shaded area of the diagram, then these pair of values can set on the pressure switch. If the point is
outside the shaded area, then these pair of values cannot be set on the pressure switch.

Page 2.02

www.condor-cpc.com

Setting reference pressure switches

Example of a pressure setting using the MDR 5 pressure diagram


The coordinates of a cut-out pressure of 4 bar and
a cut-in pressure of 2 bar intersect at a point P1
which lies within the shaded pressure range
(pressure diagram of the respective pressure
switch). These two values can be adjusted on the
pressure switch MDR 5/5. The coordinates of a
cut-out pressure of 4 bar and a cut-in pressure of
1 bar intersect at a point P2 which lies outside the
shaded pressure range of the diagram.
Accordingly, this pair of pressure values cannot
be adjusted on the pressure switch MDR 5/5.

Repeatability
The permissible tolerance of the switching values (repeatability) lies at under < 3% of the upper range value.
Service
Our service offers you the possibility of carrying out pressure settings depending on your requirements. We,
of course, can also mount any accessories you may need on demand, profiting at the same time from a
complete warrantee.

www.condor-cpc.com

Page 2.03

High performance pressure switches for AC


currents
Overview

Type designation*
Media *
No. of poles
Contact function
Voltage
Motor switching
capacity
Rated current
Flange types *

Pressure ranges (bar)


Cut-out pressure
from - to
Degree of Protection

MDR 1

MDR 1

MDR 11

MDR 11

MDR 2

MDR 21

air
2 pole
2 N.C.
230 V

water
2 pole
2 N.C.
230 V

air
2 pole
2 N.C.

water
2 pole
2 N.C.

air
2 pole
2 N.C.

air
2 pole
2 N.C.

230 V

230 V

230 V

230 V

4.0 kW

4.0 kW

4.0 kW

4.0 kW

2.2 kW

4.0 kW

20 A

20 A

20 A

20 A

16 A

G 1/4
F4 1/4
F4 3/8
F4 1/4 NPT

G 1/4 steel
G 1/4 steel *

G 1/4
F4 1/4
F4 3/8

G 1/4 steel
G 1/4 steel *

G 1/4
F4 1/4
F4 3/8
F4 1/2

24 A
G 1/4
F4 1/4
F4 3/8
F4 1/2
F4 1/4 NPT
2

2.5 - 11
IP 44

2.5 - 6
IP 44

2.5 - 11
IP 41/44

2.5 - 6
IP 41/44

1.5 12
IP 44

1.5 12
IP 41/44

-580 C

-580 C

2.5 mm

2.5 mm

Permissible media
temperature: Air
Permissible media
temperature: Water
Max. cross-section
(fine stranded)

-570 C

2.5 mm

2.5 mm

2.5 mm

2.5 mm

Standard
Cable glands

with PG 11
Z/ZK

with PG 11
Z/ZK

with PG 13.5
Z/ZK

with PG 13.5
Z/ZK

Standard
On / Off lever

with/without
EA
without
differential
setting
(only as
accessory)
with AEV
(Accessory
EV)

Without EA

with EA

with EA

without
differential
setting
(only as
accessory)

without
differential
setting
(only as
accessory)
with AEV
(Accessory
EV)

without
differential
setting
(only as
accessory)

Standard
Differential setting
Standard
Delayed (AEV)
Unloader valve (EV)

-570 C
70 C

70 C

without

without

with 2xWN *
(Accessory
PG11 - 13)
with/without
EA

with
differential
setting

with
differential
setting

without
(Accessory
EV, AEV)

without
(Accessory EV,
AEV)

* Table refers to catalogue product


* Preferred / most used media, further media, see table on page 2.11 or on demand
* e.g. four-way flange F4 3/8 (main connection G3/8, additionally 3 x G 1/4 ports)
* = switch need not be turned, use swivel nut for mounting
*4 WN = grommet

Page 2.04

www.condor-cpc.com

with 2xWN *
(Accessory
PG11 - 13)
with/without
EA

High performance pressure switches for 3phase currents


Overview

Type designation*
1

Media *
No. of poles
Contact function
3

Voltage *
Motor switching capacity
Rated current
Flange types *

Pressure ranges (bar)


Cut-out pressure
from - to
Degree of Protection
Permissible media
temperature: Air
Permissible media
temperature: Water
max. cross-section
(fine stranded)
Standard
Cable glands
Standard
On / Off lever
Standard
Differential setting
Standard
delayed (AEV) unloader
valve (EV)

MDR 3

MDR 4 S

MDR 4 SD

MDR 4 SU

MDR 5

Air and water


3 pole
3 NC
400 V
7.5 kW (11 kW)
24 A
G 1/2"
G 1/4
F4 1/2"
F4 3/8
F4 1/4"
F4 1/4" NPT
5

Air and water


3 pole
3 NC
400 V
5.5 kW
20 A

Air and water


3 pole
3 NC
400 V
5.5 kW
20 A

Air and water


3 pole
3 NO
400 V
4 kW
16 A

Air and water


3 pole
3 NC
400 V
5.5 kW
25 A

G 1/2"
G 1/4
G 1/2 + G 1/4

G 1/2"
G 1/4

G 1/2"

G 1/2"
G 1/2 + G 1/4

1.3 35
IP 54
-580 C

1.5 16
IP 44
-580 C

1.5 11
IP 44
-580 C

1.5 16
IP 44
-580 C

1.5 16
IP 54
-580 C

80 C

80 C

80 C

80 C

80 C

4.0 mm

2.5 mm

2.5 mm

2.5 mm

2.5 mm

with 2 x WN *
(Accessory PG11
- 16)
with/without
EA
with
differential setting
without
(accessory EV,
AEV)

with 2 x WN *
(Accessory PG11
- 13)
with/without
EA
with
differential setting
without
(accessory EV,
AEV)

with 2 x WN *
(Accessory PG11
- 13)

with 2 x WN *
(Accessory PG11
- 13)

without EA

without EA

with
differential setting
without
(accessory EV,
AEV)

with
differential setting
without

without
(Accessory PG11
- 16)
with/without
EA
with
differential setting
without
(accessory EV,
AEV)

* Table refers to catalogue product


* Preferred / most used media, further media, see table on page 2.11 or on demand
* e.g. four-way flange F4 3/8 (main connection G3/8, additionally 3 x G 1/4 ports)
*3 Higher voltages on demand
*4 WN = grommets

www.condor-cpc.com

Page 2.05

Control pressure switch

Overview

MDR F..H

MDR-F..Y

MDR-F..HE

MDR-F..HH

MDR-F..

Plastic

Stainless steel

High pressure

Reset function

1 SPDT*
230 V

1 SPDT*
230 V

1 SPDT*
230 V

1 SPDT*
230 V

1 SPDT*
230 V

0.55 kW

0.55 kW

0.55 kW

0.55 kW

0.55 kW

4A
G 3/8"
G 1/2"
G 1/4
1/4 NPT
Inner thread
(Die-cast
aluminum)

4A
G 3/8"
Inner thread
(plastic)

4A
G "
Inner thread
(Stainless
steel)

4A
G 3/8"
Inner thread
(Stainless
steel
+ throttle)

4A
G 3/8"

0.11 - 32

0.11 - 16

1 - 30

8 - 250

IP 54 / IP 65
WN / M 20
70 C

IP 54 / IP 65
WN / M 20
70 C

IP 54 / IP 65
WN / M 20
200 C

IP 54 / IP 65
WN / M 20
70 C

Type designation

Die-cast
aluminum

Contact function
Voltage
Motor switching
capacity
Current AC 15
Flange types
Standard (bold)

Pressure ranges (bar)


Cut-out pressure
from - to
Degree of Protection
Cable glands
Permissible media
temperature

* = SPDT with gold-flashed contacts for special applications on demand

Page 2.06

www.condor-cpc.com

Further
flanges on
demand

as MDR-F..H
further
pressure
ranges on
demand
IP 54 / IP 65
WN / M 20
70 C

Control pressure switch

Overview

Type designation
Contact function
Voltage
Motor switching
capacity
Current AC 15
Flange types

Pressure ranges
Cut-out pressure
from to
Degree of Protection
Cable glands
Permissible media
temperature

MDR 43
1 NC
1 NO
230 V

MDR 53

FF 142

FFg 142

PS 1

1 SPDT*

2 SPDT's*

2 SPDT's*

1 SPDT*

230 V

230 V

230 V

230 V

1.1 kW

0.55 kW

0.55 kW

0.55 kW

1.1 kW

8A
G 1/2
G 1/4
Inner thread
(Die-cast
aluminum)

4A
G 1/2
Inner thread
(Die-cast
aluminum)

6A
G 3/8
Inner thread
(Plastic)
G 1/4
Outer thread
(Steel)
6

10 A
G 1/4
Inner thread
(Bronze)

6A
G 3/8
Inner thread
(Plastic)
G 1/4
Outer thread
(Steel)
7

0.5 - 16 bar
IP 44
PG 11 13.5
80 C

0.3 - 16 bar
IP 54
PG 11 16
80 C

-0.4 - 40 bar
IP 55
PG 13.5
- 30 .. + 70 C

-0.4 - 40 bar
IP 65
PG 13.5
- 30 .. + 70 C

-0.8 - 31

IP 44
PG 13.5
-50..+70 C

* = SPDT with gold-flashed contacts for special applications on demand

www.condor-cpc.com

Page 2.07

Type code

For high performance pressure switches and control pressure switches MDR 43 and MDR 53
For decoding of pressure switch types: Standard settings
MDR X
See next page
For details

Pressure ranges
3 bar
/ 43.5 psi
/
300 kpa
5 bar
/72.5 psi /
500 kpa
6 bar
/87 psi /
600 kpa
8 bar
/116 psi /
800 kpa
9 bar
/ 130.5 psi/ 900 kpa
11 bar /159.5 psi
/
1100 kpa
16 bar /232 psi /
1600 kpa
25 bar /362,5 psi
/
2500 kpa MDR 3
35 bar / 507,5 psi/ 3500 kpa MDR 3
3 bar, pressure-resistant up to 25 bar MDR 5
8 bar, pressure-resistant up to 25 bar MDR 5

B
C
D
E
F
G
H
I
J
N
O

Flange
G 1/2"
G 1/4"
G 3/8"
G 1/2", 4-Way
G 1/4", 4-Way
G 3/8", 4-Way
1/4", NPT
3/8", NPT
1/4", NPT, 4-Way
3/8", NPT, 4-Way
G 1/2", Gauge connection 1/4"
G 1/4", Gauge connection 1/4"
G 3/8", Gauge connection 1/4"
G 1/4", Steel
G 1/4", Steel, with swivel nut

A
B
C
D
E
F
H
I
K
L
O
P
Q
S
T

Diaphragm
Standard
For tight pressure differential (roller diaphragm)
Suitable for use with foodstuffs

A
B
D

ON/OFF Manual Switch


With ON/OFF l
Without ON/OFF

A
B

Cut-out pressure
xxx

Pressure in digits (3-stellig


xxx= not pre-adjusted

e.g bar = 060

Version
EURO-Standard with screw terminals
US-Standard with screw terminals
EURO-Standard screw terminals and UL
Standard with quick-connects
Large wiring space (MDR 4S)
Reverse switching function, large wiring space (MDR 4SU)

Transparent Cover (MDR 4SD)


EURO-Standard with screw terminals, without pressure

AA
AB
AC
AD
FA
FC
FD
AE

Pressure (units)
A
B
C
D
E

Bar (> 1 bar => 010)


psi
Kpa (> 100 kpa => 010
Bar (< 1 bar => 100)
Kpa (< 100 kpa => 100)

differential

EURO-Standard with screw terminals and UL, without pressure


differential15

US-Standard with screw terminals, without pressure differential

AI
AJ

Cut-out pressure
xxx

Printing
Condor

Page 2.08

www.condor-cpc.com

Pressure in figures
number)

(3-figure

xxx= not pre-adjusted

Example 6 bar = 060

Type code

For high performance pressure switches and control pressure switches MDR 43 und MDR 53
For De-coding of pressure switch types: Accessories
MDR X

X
A
B
G

X
A
B
C
D
E
F
G

Special Accessories
Without special accessories
ST Mini Barb EV/AEV connector for plastic tubing

Terminal cover, VBG 4 MDR 2


Additional cable glands PG 9V MDR 3

Releases
Without release
Undervoltage release 230 V
Undervoltage release 400 V
Undervoltage release 480 V
Undervoltage release 240 V

/ 50 Hz
/ 50 Hz
/ 60 Hz
/ 60 Hz

Shunt release 24 V / 50 Hz
Shunt release 110 V / 50 Hz
Shunt release 230 V / 50 Hz

A G used by MDR 3
Valves
Without unloader valves
Unloader valves EV, screw fitting 6 mm
Unloader valves EV i, screw fitting 1/4"
Unloader valves EV S, quick-connect 6 mm
Unloader valves EV W, 90, screw fitting 6 mm
Unloader valves EV Wi, 90, screw fitting 1/4"
Unloader valves EV WS, 90, quick-connect. 6 mm
Unloader valves EV M5, screw fitting 6 mm, port fitting M5
Unloader valves EVi M5, screw fitting 1/4", port fitting M5
Unloader valves EV WSi, 90, quick-connect 1/4"
Unloader valves EV Ei, screw fitting 1/4"
Unloader valves EV L, screw fitting 6 mm, port fitting 6 mm
Unloader valves EV Li, screw fitting 1/4", port fitting 6 mm
Unloader valves AEV, screw fitting 6 mm
Unloader valves AEV i, screw fitting 1/4"
Unloader valves AEV S, quick connect 6 mm
Unloader valves AEV W, 90, screw fitting 6 mm
Unloader valves AEV Wi, 90, screw fitting 1/4"
Unloader valves AEV WS90, quick-connect 6 mm
Unloader valves AEV WSi, 90, quick-connect 1/4"
Unloader valves EV E, screw fitting 6 mm for MDR 5, 6
Unloader valves EV 5, screw fitting 6 mm, port fitting 6 mm
Unloader valves EV Si, quick-connect 6 mm

X
A
B
C
D
E
F
G
H
I
J
M
N
O
P
Q
R
S
T
U
V
W
Y

Cable grommets / blanking plug


PG 11 conduit
PG 11 Complete
PG 11 Z with strain relief
PG 11 ZK with strain relief and cable support

PG 13.5 conduit
PG 13.5 Complete
PG 13.5 Z with strain relief
PG 13.5 ZK with

strain relief and cable support

PG 16 conduit
PG 16 Complete
PG 16 Z with strain relief
PG 16 ZK with

strain relief and cable support

PG 16/13,5 ZK with

strain relief and cable support

PG 16/13,5 Z with strain relief


PG 16/11 Complete

Releases (Note use off small/capital initial letters)


Without overload relay
Without contact block
Overload relay 0.63 1.0 A
Overload relay 1.6 2.5 A
Overload relay 1.0 1.6 A
Overload relay 2.5 4.0 A
Overload relay 4.0 6.3 A
Overload relay 6.3 10.0 A
Overload relay 10.0 16.0 A
Overload relay 16.0 20.0 A
Overload relay 20.0 24.0 A
Overload relay 20.0 30.0 A, 2 pole
Overload relay 10.,0 16.0 A, for higher switching capacity
Overload relay 16.0 20.0 A, for higher switching capacity
Overload relay 20.0 24.0 A, for higher switching capacity

Overload relay 0.86 1.5 A


Overload relay 1.5 2.45 A
Overload relay 2.4 4.2 A
Overload relay 4.0 7.0 A
Overload relay 6.1 10.3 A
Overload relay 9.0 14.0 A
Overload relay 11.0 18.0 A
Overload relay 18.0 25.0 A - 2 pole

D O used by MDR 3
Q Y used by MDR 5

Cable glands
Without cable glands

X
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Y

X
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O O
P P
X
A
B
C
D
E
F
G
H
I
J
K
L
M

www.condor-cpc.com

Page 2.09

Type code for control pressure switch MDR-F

For decoding pressure switch types: Standard settings and Accessories


MDR - F

Factory settings pressure


range

Pressure range
002
004
008
010
012
016
030
032
060
120
250

2 bar
4 bar
8 bar
10 bar
12 bar
16 bar
30 bar
32 bar
60 bar
120 bar
250 bar

A
B
C
D
E
F
G
H

> 1 bar und < 100 bar


> 100 bar
< 1 bar
< 1000 psi
> 1000 psi
> 100 kpa and < 10000 kpa
> 10000 kpa
< 100 kpa
e.g. 7 15 bar => 070A150

Cable glands
Flange/ Material
Polyamide (plastic)
Silumin (Die-cast aluminum)

Y
H

A
B
C
D

Rubber grommet
M 20 cable gland
2 x Rubber grommets
2 x M 20 cable glands

A
H
L
D

Auto
Max. - Reset
Min. - Reset
Run dry protection

A
B

Microswitch, 1 SPDT
Microswitch, 1 SPDT, gold-flashed

A
S

Cage clamps
Screw terminals

Switching function
Diaphragm
A
V
H
E

Perbunan
Viton
High pressure
Stainless steel

Output contacts

Flange type / Thread


G 3/8"
G 1/2"
G 1/4"
G 1/4", NPT

Page 2.10

A
B
C
D

www.condor-cpc.com

Terminals

Diaphragm resistance

Diaphragm media resistance for pressure switches


Type of pressure switch

Catalogue page
Medium

Diaphragm
material

Acetone CH3COCH3
Acetylene HC = CH
Air
Ammonia, watery 100 %
Ammonia, 25 % (ammonia
solution)
Benzene
Butane C4H10
Butyl acetate CH3COOC4H9
Butyl alcohol CH3-CH2-CH2-CH2OH
Carbon dioxide CO2
Carbonic acid H2CO3
Chlorine Cl2
Cooling liquid
Diesel
Dimethylbenzene C6H4(CH3)2
Ethyl acetate CH3OOOC2H5
Ethylene glycol CH2OH- CH2OH
Fuel oil
Gasoline
Glycerol CH2OH-CHOH-CH2OH
Hydrogen H2
Methyl chloride CH3Cl
Mineral oils
Natural gas
Nitrogen N2
Oxygen O2
Ozone
Perchlorethylene CCI2=CCL2
Petroleum
Phenolic acid C6H5(OH)
Propane C3H8
Protective gas
Silicon oil
Sulphur dioxide SO2
Silicon oil
Synthetic oils
Toluene (Phenylmethane)
C6H5CH3
Trichlorethene CHCI=CCI2
Urine
Vegetable oil
Vinegar 25 %
Water H2O
Water Distilled, aired
Water sea water
Water steam

MDR F
MDR 3 USA
MDR F
MDR 5
FF(g) 142
4.02, 3.14,
3.26, 4.16
NBR
Perbunan
1
1

MDR F

MDR F

MDR 43

(high
pressure)

FF(g) 142

MDR 53

4.02

4.02, 4.11

4.02, 4.11

4.06, 4.08

3.14

FPM
Viton
X
1
1
X

Polyacetal
POM

Stainless
steel
1
1
1
1

CR + PA6.6
603 C

CR
1031/55
2
1
1
X

1
1

1
1
X

1
1
1

1
1

MDR 3
RM

MDR 1
MDR 11
3.02,
3.05
TPE
Hytrel

MDR 2
MDR 21
MDR 3
MDR 4
3.08, 3.11,
3.14, 3.21
NBR/SBR
NL348-1

1
1

1
1

1
X

1
1
1
1
1

1
1
1
1
1
1

1
1

1
1
1
1
1

1
1
1
1
1
1
1
1
1
1
1
1
1

1
1
1

1
1

1
1

1
1
X

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1
1

1
1
1
1
1
1

1
1

1
1
1
1
1
1
1
1

1
1
1
1

1
1
X
X

1
1
1

1
1
2
1

X
X
2
1
X
2
1
1
X
2
1
1

1
2
2

1
X
1

2
1
2

1
1

2
1
1

2
X
2

1
1
1

1
1
1
1

1
2
X

1
1
1
1
1

Messing

1
1

4.20

1
2
1
2

1
1
1

PS 1

1
1
1
1
1

1
1
1
1
1

1
1
1
1
1

1 = resistant, 2 = limited resistance, x = not resistant, empty field = not tested


The data in the table results not only from laboratory tests but also from year long experience. These serve as reference points. Since
the chemical effect of a given media may be affected by additives, temperature differences and mixtures amongst themselves, we
recommend carrying out a media resistance test before using the product.

www.condor-cpc.com

Page 2.11

Page 2.12

www.condor-cpc.com

High performance pressure switches

High performance pressure switches for AC currents


Page
3.02

MDR 1

AC current; switching capacity 4.0 kW


Max. cut-out pressure 11 bar

MDR 11

AC current; switching capacity 4.0 kW


Max. cut-out pressure 11 bar / 160 psi
UL / CSA-approval

3.05

MDR 2

AC current; switching capacity 2.2 kW


Max. cut-out pressure 12 bar

3.08

MDR 21

AC current; switching capacity 4.0 kW


Max. cut-out pressure 12 bar / 175 psi
UL / CSA-approval

3.11

High performance pressure switches for


3-phase currents
MDR 3

3-phase; switching capacity 7.5 (11) kW


available with overload relays
Max. cut-out pressure 35 bar
UL / CSA-approval

3.14

MDR 4

3-phase; switching capacity 4.0 / 5.5 kW


Max. cut-out pressure 16 bar

3.21

MDR 5

3-phase; switching capacity 5.5 kW


available with overload relays
Max. cut-out pressure 16 bar

3.26

www.condor-cpc.com

Page 3.01

Pressure switch MDR 1

Pressure switch MDR 1 / 6, Pump version


Single phase
Switching capacity 4.0 kW
Max. cut-out pressure 6 bar
Incl. cable glands PG 11 Z/ZK
2-pole (N.C.) Steel flange
Acc. to EN 60947
Optional differential adjustment
Steel flange ST-

Type overview MDR 1 / 6 bar


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

MDR-1 DSD BAEA 017A030 XDE XXX


MDR-1 DTD BAEA 017A030 XDE XXX

2.5 - 6
2.5 - 6

G 1/4" ST
G 1/4" ST-

220
220

212119
212126

Cable glands for retrofitting see Accessories!

Pressure switch MDR 1 / 11, Compressor version


Single phase
Switching capacity 4.0 kW
Max, cut-out pressure 11 bar
Incl. cable glands PG 11 Z/ZK and unloader valve AEV 1 S
2-pole (N.C.)
Acc. to EN 60947
Optional differential adjustment
MDR 1/11.. +EA

Type overview MDR 1 / 11 bar


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

MDR-1 GBA AAEA 060A080 QDE XXX


EA
MDR-1 GEA AAEA 060A080 QDE XXX
EA
MDR-1 GFA AAEA 060A080 QDE XXX
EA
MDR-1 GBA BAEA 060A080 QDE XXX
MDR-1 GEA BAEA 060A080 QDE XXX
MDR-1 GFA BAEA 060A080 QDE XXX
Unloader valves and cable glands for retrofitting see Accessories!

2.5 - 11
2.5 - 11
2.5 - 11
2.5 - 11
2.5 - 11
2.5 - 11

Flange

Weight
in g

Part No.

G 1/4"
F4
F4 3/8
G 1/4"
F4 1/4 "
F4 3/8

220
220
220
220
220
220

212133
212140
212157
216049
216025
216063

Technical Data MDR 1


Technical Data MDR 1 acc. to EN 60947
Rated insulation voltage
Ui
Motor switching capacity (AC 3)
Ue=240 V (1~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz

Technical Data MDR 1 acc. to EN 60947


500 V
4.0 kW
5

> 1 x 10
> 5 x 10

120

Permissible media temperature


Air
Permissible media temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ..
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

- 5...+ 80 C
+ 70 C
IP 44
2

2.5 / 2.5mm

2.5 / 2.5mm

600

Diaphragm media resistance MDR 1


20 A
> 35 bar

Acetylene, Butane, Ethylene glycol, Carbon


dioxide, Air, Mineral oils, Water, Distilled
water, Sea water, Hydrogen, Water steam

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Page 3.02

www.condor-cpc.com

Pressure switch MDR 1

Dimensions / Circuit Diagrams MDR 1

Pressure switch MDR-1

Accessories MDR 1
Order reference

Description

Weight
in g

Part No

EV 1S

Unloader valves
with quick-connect 6 mm for plastic unloader valves

25

226765

AEV 1S

Delayed unloader valves


with quick-connect 6 mm for plastic unloader valves

25

217541

WN
PG 11 G
PG 11 Z
PG 11 ZK

Cable glands
Grommet
Conduits for mounting of cable glands (Inner thread)
With strain relief
With strain relief and cable support

6
6
12
12

255017
255024
255031
255048

H1

Cover
Cover without On/Off lever (Neutral version, without marking)

40

230700

40

227366

40

230717

20

230618

(Cover MDR 1)
H1-EA (Cover MDR 1+EA)

Cover MDR 1 + EA + lever

Cover with On/Off lever for manual On/Off (Neutral version, without
marking)
Conversion kit H1 to cover H1-EA

MDR-1 Differential kit

Differential adjustment
Kit for setting cut-in and differential pressures (10 pcs.)

Unloader valves / Delayed unloader valves

EV 1S

AEV 1S

EV 1S / AEV 1S

www.condor-cpc.com

Page 3.03

Pressure switch MDR 1

Cable glands MDR 1

Grommet

PG 11 G

PG 11 Z

PG 11 ZK

Pressure Diagrams MDR 1

Explanation
Devices without differential pressure adjustment
After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. If only the cut-out pressure is known,
the cut-in pressure to be set can also be determined from the diagram.
Example: MDR 1/6 without differential pressure adjustment
For a preselected cut-in pressure of 4 bar, the cut-out pressure is 5 bar. If, for example, the cut-out pressure is to be 4 bar, a cut-in
pressure of approx. 2.7 bar has to be set.
Devices with differential pressure adjustment
An intersecting point is determined in the diagram by selecting a pair of cut-in and cut-out pressure values. If this point lies within the
shaded area, this pair of values can be set on the pressure switch. If this point lies outside the shaded area, these values cannot be set.
Example: MDR 1/11 with differential pressure adjustment
With a preselected cut-in pressure of 4 bar, the cut-out pressure can be determined and set between 5.4 and 8 bar using the differential
pressure adjustment

Page 3.04

www.condor-cpc.com

Pressure switch MDR 11

Pressure switch MDR 11 / 6, Pump version


Single phase
Switching capacity 4.0 kW / 4 Hp
Max. cut-out pressure 6 bar / 87 psi
Incl. cable glands PG13.5 Z/ZK
2-pole (N.C.) Steel flange
Acc. to EN 60947
UL / CSA-approval
Optional differential adjustment

Steel flange ST-

Type Overview MDR 11 / 6 bar


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

EA
EA

2.5 - 6
2.5 - 6

G 1/4" ST
G 1/4" ST-

300
320

235712
235729

MDR-11 DSD AAIA 017A030 XDE XXX


MDR-11 DTD AAIA 017A030 XDE XXX
Cable glands for retrofitting see Accessories!

Pressure switch MDR 11 / 11, Compressor version


Single phase
Switching capacity 4.0 kW / 4 HP
Max. cut-out pressure 11 bar / 160 psi
Incl. cable glands PG13,5 Z/ZK
With delayed unloader valve AEV 11 S
2-pole (N.C.)
Acc. to EN 60947
UL / CSA-approval
Optional differential adjustment

Type Overview MDR 11 / 11 bar


Order reference
MDR-11 GBA AAIA 060A080 QDE XXX
MDR-11 GEA AAIA 060A080 QDE XXX

ON / OFF lever

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

EA
EA

2.5 11
2.5 11

G 1/4"
F4

300
320

235736
235743

Unloader valves and cable glands for retrofitting see Accessories!

Technical Data MDR 11


Technical Data MDR 11 acc. to 60947 UL/CSA
Rated insulation voltage
Ui
Motor switching capacity (AC 3)
Ue=240 V (1~)
Motor switching capacity (UL 508, CSA
22.2) Ue=240 V (1~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie (EN 60947)
bei 240 V AC
Rated operational current Ie (UL/CSA)
bei 240 V AC

Technical Data MDR 11 acc. to 60947 UL/CSA

500 V
4.0 kW
4.0 HP
> 1 x 10

> 5 x 10

120

Bursting strength Pz
Permissible medium temperature
Air
Permissible medium temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ..
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

> 35 bar
- 5...+ 80 C
+ 70 C
IP 44
2

2.5 / 2.5mm

2.5 / 2.5mm

600

Diaphragm media resistance MDR 11


20 A
26 A

Acetylene, Butane, Ethylene glycol, Carbon


dioxide, Air, Mineral oils, Water, Distilled
water, Sea water, Hydrogen, Water steam

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

www.condor-cpc.com

Page 3.05

Pressure switch MDR 11

Dimensions / Circuit Diagrams MDR 11

Pressure switch MDR-11

Accessories MDR 11
Order
reference
EV 1 S
EV 1 WSi

Description
Unloader valves
with quick-connect 6 mm for plastic unloader valves
90 unloader valve with quick-connect for 1/4 plastic tubes, quick-connect can be
rotated 360

Weight
in g

Part No.

25
25

226765
247593

AEV 1 S

Delayed unloader valves


with quick-connect 6 mm for plastic unloader valves

25

217541

WN
PG 13.5 Z-21
PG 13.5 ZK-21

Cable glands
Grommets
With strain relief
With strain relief and cable support

6
12
12

201243
201021
201038

Differential pressure adjustment


Kit for setting cut-in and differential pressures (10 pcs.)

20

230618

MDR-1
Differential kit

Unloader valves / Delayed unloader valves

EV 1S

EV 1WSi

AEV 1S

Cable glands MDR 11

WN

Page 3.06

PG 13.5 Z-21

www.condor-cpc.com

PG 13.5 ZK-21

Pressure switch MDR 11


Dimensions, Accessories MDR 11

EV 1S / AEV 1S

EV 1WSi

Pressure Diagrams MDR 11

1 bar = 14,5 psi; 10 psi approx. 0,7 bar

Explanation
Devices without differential pressure adjustment
After selecting the cut-in pressure, the cut-out pressure can be read from the pressure diagram. If only the cut-out pressure is known,
the cut-in pressure to be set can also be determined from the diagram.
Example: MDR 1/6 without differential pressure adjustment
For a preselected cut-in pressure of 4 bar, the cut-out pressure is 5 bar. If, for example, the cut-out pressure is to be 4 bar, a cut-in
pressure of approx. 2.7 bar has to be set.
Devices with differential pressure adjustment
An intersecting point is determined in the diagram by selecting a pair of cut-in and cut-out pressure values. If this point lies within the
shaded area, this pair of values can be set on the pressure switch. If this point lies outside the shaded area, these values cannot be set.
Example: MDR 1/11 with differential pressure adjustment
With a preselected cut-in pressure of 4 bar, the cut-out pressure can be determined and set between 5.4 and 8 bar using the differential
pressure adjustment

www.condor-cpc.com

Page 3.07

Pressure switch MDR 2


Pressure switch MDR 2
Single phase
Switching capacity 2.2 kW
Max. cut-out pressure 12 bar
2-pole (N.C.)
Acc. to EN 60947

Type overview MDR 2


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

MDR-2 DBA AAAA 015A030 XAA XXX


MDR-2 GBA AAAA 070A090 XAA XXX
MDR-2 GEA AAAA 070A090 XAA XXX
MDR-2 GFA AAAA 070A090 XAA XXX
MDR-2 GDA AAAA 070A090 XAA XXX
MDR-2 DBA BAAA 015A030 XAA XXX
MDR-2 GBA BAAA 070A090 XAA XXX
MDR-2 GEA BAAA 070A090 XAA XXX
MDR-2 GFA BAAA 070A090 XAA XXX
MDR-2 GDA BAAA 070A090 XAA XXX

EA
EA
EA
EA
EA
-

1.5 - 7
4 - 12
4 - 12
4 - 12
4 - 12
1.5 - 7
4 - 12
4 - 12
4 - 12
4 - 12

G 1/4"
G 1/4"
F4 1/4"
F4 3/8"
F4 1/2"
F4 1/4"
F4 1/4"
F4 1/4"
F4 3/8"
F4 1/2"

300
300
320
320
320
300
300
320
320
320

212164
212171
212188
212195
212201
217381
217404
219408
226888
226895

Unloader valves and cable glands for retrofitting see Accessories!

Technical Data MDR 2


Technical Data MDR 2 acc. to 60947
Rated insulation voltage
Ui
Motor switching capacity (AC 3)
Ue=240 V (1~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz
Permissible medium temperature
Air

Technical Data MDR 2 acc. to 60947


500 V
2.2 kW
5

> 1 x 10
> 5 x 10

Page 3.08

www.condor-cpc.com

+ 80 C
IP 44
2

2.5 / 2.5mm

2.5 / 2.5mm

120
600

Diaphragm media resistance MDR 2


20 A
> 35 bar
- 5...+ 80 C

Dimensions / Circuit Diagrams MDR 2

Pressure switch MDR-2

Permissible medium temperature


Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ..
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

Air, Water

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Pressure switch MDR 2


Accessories MDR 2
Order
reference

Description

Weight
in g

Part No.

90 with quick-connect for 6 mm plastic discharge tubes

25
25
25
15
15

200666
200680
200697
200703
200710

AEV 2S
AEV 2W
AEV 2Wi
AEV 2WS

Delayed unloader valves


With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or copper discharge tubes
90 with screw connection for 1/4" mm plastic or copper discharge tubes
90 with quick-connect for 6 mm plastic discharge tubes

25
15
15
15

200741
200758
200765
200772

WN
PG 11 G
PG 11 V
PG 11 Z
PG 11 ZK
PG 13.5 G
PG 13.5 V
PG 13.5 Z
PG 13.5 ZK

Cable glands
Grommet
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support

6
6
12
12
12
6
12
12
12

200888
200895
200901
00925
200918
200963
200932
200956
200949

H2

Cover
Cover without On/Off lever (Neural version without marking)

40

217510

Cover with On/Off lever for manual On/Off (neutral version, without marking)

40

229445

Unloader valves
With screw connection for 6 mm plastic or copper discharge tubes
With quick-connect for 6 mm plastic discharge tubes

EV 2
EV 2S
EV 2W
EV 2Wi
EV 2WS

90 with screw connection for 6 mm plastic or discharge copper tubes


90 with screw connection for 1/4" mm plastic or discharge copper tubes

(Haube MDR 2)
H2-EA (Haube
MDR 2+EA)

Unloader valves / Delayed unloader valves

EV 2

EV 2S

AEV 2S

EV 2W / EV 2Wi

AEV 2W / AEV 2Wi

EV 2WS

AEV 2WS

www.condor-cpc.com

Page 3.09

Pressure switch MDR 2


Cable glands MDR 2

WN

PG .. G

PG .. V

PG .. Z

PG .. ZK

Dimensions, Accessories MDR 2

EV 2

EV 2S

EV 2W / EV 2Wi
AEV 2W / AEV 2Wi

EV 2WS
AEV 2WS

Pressure Diagrams

Page 3.10

www.condor-cpc.com

AEV 2S

Pressure switch MDR 21


Pressure switch MDR 21
Single phase
Switching capacity 2.2 kW
Max. cut-out pressure 12 bar / 175 psi
2-pole (N.C.)
Acc. to EN 60947
UL / CSA-approval

Type overview MDR 21


Order reference
MDR-21 DBA AACA 015A030 XAA XXX
MDR-21 DEA AACA 015A030 XAA XXX
MDR-21 GBA AACA 070A090 XAA XXX
MDR-21 GEA AACA 070A090 XAA XXX
MDR-21 DBA BACA 015A030 XAA XXX
MDR-21 DEA BACA 015A030 XAA XXX
MDR-21 GBA BACA 070A090 XAA XXX
MDR-21 GEA BACA 070A090 XAA XXX

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

EA
EA
EA
EA
-

1.5 - 7
1.5 - 7
4 - 12
4 - 12
1.5 - 7
1.5 - 7
4 - 12
4 - 12

G 1/4"
F4 1/4"
G 1/4"
F4 1/4"
G 1/4"
F4 1/4"
G 1/4"
F4 1/4"

300
320
300
320
300
320
300
320

212218
212225
212232
212249
219910
226901
226918
226925

Unloader valves and cable glands for retrofitting see Accessories!

Technical Data MDR 21


Technical Data MDR 21 acc. to EN 60947
Rated insulation voltage
Ui
Motor switching capacity
(UL 508, CSA 22.2)Ue=120 V (1~)
Motor switching capacity
(UL 508, CSA 22.2)Ue=240 V (1~)
Motor switching capacity
(AC 3)Ue=240 V (1~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz

Technical Data MDR 21 acc. to EN 60947


500 V
2 HP
4 HP

2.2 kW
5

> 1 x 10
> 5 x 10

Permissible medium temperature


Air
Permissible medium temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ..
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

- 5...+ 80 C
+ 80 C
IP 44
2

2.5 / 2.5mm

2.5 / 2.5mm

120

Diaphragm media resistance MDR 21


600
24 A
> 35 bar

Air, Water

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Dimensions / Circuit Diagrams MDR 21

www.condor-cpc.com

Page 3.11

Pressure switch MDR 21


Accessories MDR 21
Order
reference

Description

Weight
in g

Part No.

90 with quick-connect for 6 mm plastic discharge tubes

25
25
15
15
15

200666
200680
200697
200703
200710

AEV 2S
AEV 2W
AEV 2Wi
AEV 2WS

Unloader valves for difficult motor starting conditions


With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or copper discharge tubes
90 with screw connection for 1/4" mm plastic or copper discharge tubes
90 with quick-connect for 6 mm plastic discharge tubes

25
15
15
15

200741
200758
200765
200772

WN
PG 13.5 Z-21
PG 13.5 ZK-21

Cable glands
Grommet
With strain relief
With strain relief and cable support

6
12
12

201243
201021
201038

H 21

Cover
Cover without On/Off lever (Neural version without marking)

40

229452

Cover with On/Off lever for manual On/Off (neutral version, without marking)

40

217503

Unloader valves
With screw connection for 6 mm plastic or copper discharge tubes
With quick-connect for 6 mm plastic discharge tubes

EV 2
EV 2S
EV 2W
EV 2Wi
EV 2WS

90 with screw connection for 6 mm plastic or discharge copper tubes


90 with screw connection for 1/4" mm plastic or discharge copper tubes

(Cover MDR 21)


H 21-EA (Cover
MDR 21+EA)

Unloader valves / Delayed unloader valves

EV 2

EV 2S

AEV 2S

EV 2W / EV 2Wi

AEV 2W / AEV 2Wi

EV 2WS

AEV 2WS

Cable glands MDR 21

WN

Page 3.12

PG 13,5 Z-21

www.condor-cpc.com

PG 13,5 ZK-21

Pressure switch MDR 21


Dimensions, Accessories MDR 21

EV 2

EV 2S

EV 2W / EV 2Wi
AEV 2W / AEV 2Wi

EV 2WS / AEV 2WS

AEV 2S

Pressure Diagrams

1 bar = 14,5 psi; 10 psi approx. 0,7 bar

www.condor-cpc.com

Page 3.13

Pressure switch MDR 3


Pressure switch MDR 3

3-phase
Switching capacity 7.5 (11) kW
Available with overload relay
Max. cut-out pressure 35 bar
3-pole (N.C.)
Acc. to EN 60947
UL / CSA-approval

Type overview MDR 3


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

MDR-3 DAA AAAA 045A060 XAA XXX


MDR-3 GAA AAAA 090A110 XAA XXX
MDR-3 GBA AAAA 090A110 XAA XXX
MDR-3 GEA AAAA 090A110 XAA XXX
MDR-3 GDA AAAA 090A110 XAA XXX
MDR-3 DFA AAAA 090A110 XAA XXX
MDR-3 HAA AAAA 130A160 XAA XXX
MDR-3 HBA AAAA 130A160 XAA XXX
MDR-3 HEA AAAA 130A160 XAA XXX
MDR-3 HDA AAAA 130A160 XAA XXX
MDR-3 HFA AAAA 130A160 XAA XXX
MDR-3 IAA AAAA 215A250 XAA XXX
MDR-3 IDA AAAA 215A250 XAA XXX
MDR-3 JAA AAAA 320A350 XAA XXX
MDR-3 JDA AAAA 320A350 XAA XXX
MDR-3 DAA BAAA 045A060 XAA XXX
MDR-3 GAA BAAA 090A110 XAA XXX
MDR-3 GBA BAAA 090A110 XAA XXX
MDR-3 GEA BAAA 090A110 XAA XXX
MDR-3 GDA BAAA 090A110 XAA XXX
MDR-3 DFA BAAA 090A110 XAA XXX
MDR-3 HAA BAAA 130A160 XAA XXX
MDR-3 HBA BAAA 130A160 XAA XXX
MDR-3 HEA BAAA 130A160 XAA XXX
MDR-3 HDA BAAA 130A160 XAA XXX
MDR-3 HFA BAAA 130A160 XAA XXX
MDR-3 IAA BAAA 215A250 XAA XXX
MDR-3 IDA BAAA 215A250 XAA XXX
MDR-3 JAA BAAA 320A350 XAA XXX
MDR-3 JDA BAAA 320A350 XAA XXX

EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
-

1.3 - 6
4 - 11
4 - 11
4 - 11
4 - 11
4 - 11
6 - 16
6 - 16
6 - 16
6 - 16
6 - 16
7.5 25
7.5 25
12 35
12 - 35
1,3 - 6
4 - 11
4 - 11
4 - 11
4 - 11
4 - 11
6 - 16
6 - 16
6 - 16
6 - 16
6 - 16
7.5 25
7.5 25
12 35
12 - 35

G 1/2"
G 1/2"
G 1/4"
F4 1/4"
F4 1/2"
F4 3/8"
G 1/2"
G 1/4"
F4 1/4"
F4 1/2"
F4 3/8"
G 1/2"
F4 1/2"
G 1/2"
F4 1/2"
G 1/2"
G 1/2"
G 1/4"
F4 1/4"
F4 1/2"
F4 3/8"
G 1/2"
G 1/4"
F4 1/4"
F4 1/2"
F4 3/8"
G 1/2"
F4 1/2"
G 1/2"
F4 1/2"

610
610
610
640
640
640
610
610
640
640
640
610
640
610
640
590
590
590
620
620
620
590
590
620
620
620
590
620
590
620

212256
212263
212270
212287
212294
212300
212317
212324
212313
212348
212355
212362
212379
229711
229728
226932
226949
226956
226963
226970
226987
226994
227007
227014
227021
227038
227045
227052
229698
229704

Unloader valves and cable glands for retrofitting see Accessories!

Page 3.14

www.condor-cpc.com

Pressure switch MDR 3


Type overview Pressure Switch MDR 3 RM versions, with roller diaphragm
Tight pressure differential
Extended medium resistance
Replacement for MDR 6
Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Succesor of

Flange

Weight
in g

Part
No.

MDR-3 DAB BAAA 028A035 XAA XXX


MDR-3 GAB BAAA 060A070 XAA XXX
MDR-3 GOB BAAA 060A070 XAA XXX
MDR-3 GAB AAAA 060A070 XAA XXX
MDR-3 GOB AAAA 060A070 XAA XXX
MDR-3 HAB BAAA 145A160 XAA XXX
MDR-3 HOB BAAA 145A160 XAA XXX
MDR-3 HAB AAAA 145A160 XAA XXX
MDR-3 HOB AAAA 145A160 XAA XXX

EA
EA
,
EA
EA

1.3 - 6
4 - 11
4 - 11
4 - 11
4 - 11
4 - 11
6 - 16
6 - 16
6 - 16

MDR 6/11-1/2
MDR 6/11 -1/2+1/4
MDR 6/11 K -1/2

G 1/2"
G 1/2"
G 1/2+1/4"
G 1/2"
G 1/2+1/4"
G 1/2"
G 1/2+1/4"
G 1/2"
G 1/2+1/4"

770
770
810
800
850
770
810
800
800

229674
227595
227601
227632
227649
227618
227625
227656
227663

MDR 6/11 K-1/2+1/4

MDR 6/16 -1/2


MDR 6/16 -1/2+1/4
MDR 6/16 K -1/2
MDR 6/16 K -1/2+1/4

Unloader valves and cable glands for retrofitting see Accessories!

Technical Data MDR 3


Technical Data MDR 3
acc. to EN 60947 UL / CSA
Rated insulation voltage
Ui
Motor switching capacity
(UL 508, CSA 22.2) Ue=120 V (1~)
Motor switching capacity
(AC 3) Ue=240 V (1~)
Motor switching capacity
(UL 508, CSA 22.2) Ue=240 V (1~)
Motor switching capacity
(AC 3) Ue=240 V (3~)
Motor switching capacity
(UL 508, CSA 22.2) Ue=240 V (3~)
Motor switching capacity
(AC 3) Ue=400 V (3~)
Motor switching capacity
(UL 508, CSA 22.2) Ue=480 V (3~)
Motor switching capacity (AC 3)
Ue=500 V (3~)
Motor switching capacity
(UL 508, CSA 22.2) Ue=600 V (3~)
Motor switching capacity
(AC 3) Ue=690 V (3~)

Technical Data MDR 3


acc. to EN 60947 UL / CSA
690 V
2 HP
5.5 kW
5 HP
5.5 kW
7.5 HP
7.5/11* kW
15 HP
7.5/11* kW
20 HP
7.5/11* kW

Diaphragm media resistance MDR 3


Air, Water

Permissible medium temperature


Air
Permissible medium temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ...
Fine stranded 1 x / 2 x
Conductor cross-section 1
Rigid cable 1 x / 2 x

> 1 x 10

> 1 x 10

120
600
24 A
16 > 40 bar
> 25 > 60 bar
-5...+ 80 C
+ 80 C
IP 54
2

4 / 2.5 mm

6 / 4 mm

Diaphragm media resistance MDR 3 USA


resistant

Diaphragm media resistance MDR 3 RM


Acetylene, Ammonia 25%, Butane, Natural
gas, Vinegar 25 %, Ethylene glycol,
Glycerol, Urine, Carbon dioxide, Carbonic
acid, Air, Vegetable oil, Propane, Silicon oil,
Nitrogen, Water, Hydrogen, Sea water

Electrical life (AC 3)


Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz

resistant

Acetylene, Gasoline, Butane, Diesel,


Natural gas, Petroleum, Ethylene glycol,
Glycerol, Fuel oil, Urine, Carbon dioxide,
Carbonic acid, Air, Mineral oils, Vegetable
oil, Propane, Silicon oil, Nitrogen, Synthetic
oils, Water, Distilled water, Hydrogen, Sea
water, Water steam

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

* With arc-chamber Sk- H on demand

www.condor-cpc.com

Page 3.15

Pressure switch MDR 3


Dimensions MDR 3

Pressure switch MDR-3

Circuit Diagrams MDR 3

MDR 3

MDR 3 EA 3 R 3 RA 3

MDR 3 EA 3 R 3 RU 3

MDR 3 EA 3 RA 3

MDR 3 EA 3 RU 3

MDR 3 EA 3 R 3

Accessories Hourmeter kit MDR 3


Description
The MDR 3 can be equipped or retrofitted with an operating hourmeter to monitor
the pump and compressor running time.
The hourmeter is available as a kit and can be attached to the cover in 4 different
positions, each offset at an angle of 90.
This ensures optimum readability. The kit consists of an operating hourmeter for
either 230 V or 400 V and a perforated MDR 3 cover with or without ON/OFF lever.

Type overview Hourmeter kit


Order
reference
H3 - B 230
H3 - B 400
H3-EA - B 230
H3-EA - B 400

Page 3.16

Description
Hourmeter and Cover for MDR-3
Hourmeter and Cover for MDR-3
Hourmeter and Cover for MDR-3+EA
Hourmeter and Cover for MDR-3+EA

www.condor-cpc.com

Voltage
230 V / 50 Hz
400 V / 50 Hz
230 V / 50 Hz
400 V / 50 Hz

Packing
(units)

Part No.

1
1
1
1

237297
237303
237310
237327

Pressure switch MDR 3


Accessories MDR 3
Order
reference

Description

Weight
in g

Part No.

EV 3
EV 3i
EV 3S*
EV 3W*
EV 3Wi*
EV 3WS*
EV 3L

Unloader valves
With screw connection for 6 mm plastic or copper discharge tubes
With screw connection for 1/4 plastic or copper discharge tubes
With quick-connect for 6 mm plastic discharge tubes
90 unloader valve with screw connection for 6 mm plastic or copper discharge tubes
90 unloader valve with screw connection for 1/4 plastic or copper discharge tubes
90 unloader valve with quick-connect for 6 mm plastic discharge tubes
With screw connection for 6 mm plastic or copper discharge tubes

25
25
25
18
18
10
30

201045
201052
201069
201076
201083
201090
201229

AEV 3
AEV 3S*
AEV 3W*
AEV 3Wi*
AEV 3WS*

Delayed unloader valves


With screw connection for 6 mm plastic or copper discharge tubes
With quick-connect for 6 mm plastic discharge tubes
90 unloader valve with screw connection for 6 mm plastic or copper discharge tubes
90 unloader valve with screw connection for 1/4 plastic or copper discharge tubes
90 unloader valve with quick-connect for 6 mm plastic discharge tubes

25
25
18
18
10

201106
201120
201137
201144
201151

PG 9 Z

Cable glands
With strain relief (for additional wiring)

12

201373

WN
PG 11 G
PG 11 V
PG 11 Z
PG 11 ZK
PG 13.5 G
PG 13.5 V
PG 13.5 Z
PG 13.5 ZK
PG 16 G
PG 16 V
PG 16 Z
PG 16 ZK

Grommet
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support

6
6
12
12
12
6
12
12
12
6
12
12
18

201243
201250
201267
201274
201281
201298
201304
201311
201328
201335
201342
201359
201366

MW

Mounting bracket

65

230021

Cover
Cover without rotary knob (Neutral version, without marking)

100

229490

Cover with rotary knob for manual On/Off (Neutral version, without marking)

100

230007

SK 3
SK 3-S
SK R3/ 1,0
SK R3/ 1,6
SK R3/ 2,5
SK R3/ 4,0
SK R3/ 6,3
SK R3/ 10,0
SK R3/ 16,0
SK R3/ 20,0
SK R3/ 24,0
SK R3/ 30/2

Thermal, 3-pole overload relay


Arc-chamber without lock mechanism (supplied as standard with MDR 3...)
SK 3-S Arc-chamber with lock mechanism (supplied as standard with MDR 3...+EA)
0.63 1.00 A
1.00 1.60 A
1.60 2.50 A
2.50 4.00 A
4.00 6.30 A
6.30 10.00 A
10.00 16.00 A
16.00 20.00 A
20.00 24.00 A
22.00 30.00 A, 2 pole

90
110
145
145
145
145
145
145
145
145
145
145

201380
201397
201403
201410
201427
201434
201441
201458
201465
201472
201489
201496

RU 3/24-50
RU 3/230-50
RU 3/400-50
RA 3/24-50
RA 3/110-50
RA 3/230-50
RA 3/240-60
RA 3/400-50
RA 3/480-60

Undervoltage and shunt releases


Undervoltage release 24 V, 50 Hz
Undervoltage release 230 V, 50 Hz
Undervoltage release 400 V, 50 Hz
Shunt release 24 V, 50 Hz
Shunt release 110 V, 50 Hz
Shunt release 230 V, 50 Hz
Shunt release 240 V, 60 Hz
Shunt release 400 V, 50 Hz
Shunt release 480 V, 60 Hz

100
100
100
100
100
100
100
100
100

226857
201540
201557
201564
201571
201588
214113
225935
201595

H3
(Cover MDR 3)
H3-EA (Cover
MDR 3+EA)

*up to 16 bar

www.condor-cpc.com

Page 3.17

Pressure switch MDR 3

Unloader valves / Delayed unloader valves

EV 3 / EV 3i

EV 3S

EV 3W / EV 3Wi

AEV 3S

AEV 3W / AEV 3Wi

AEV 3

EV 3L

EV 3WS

AEV 3WS

Cable glands MDR 3

WN

PG .. G

PG .. V

PG .. Z

PG .. ZK

Wall-mounting bracket, 3-pole overload relay, Undervoltage and shunt releases

MW 3

SK 3

SK 3-S

SK R3 / ..

RU ..
Pg 9 Z

Page 3.18

www.condor-cpc.com

RA ..

Pressure switch MDR 3


Dimensions, Accessories MDR 3

EV 3 / EV 3i

EV 3L

EV 3S

EV 3W / EV 3Wi
AEV 3W / AEV 3Wi

AEV 3S

AEV 3

EV 3WS / AEV 3WSi

Tripping curves R3 (average)

www.condor-cpc.com

Page 3.19

Pressure switch MDR 3

Pressure Diagrams MDR 3

Page 3.20

www.condor-cpc.com

Pressure switch MDR 4


Pressure switch MDR 4 S
3-phase
Switching capacity 4.0 / 5.5 kW
Max. cut-out pressure 16 bar
3-pole (N.C.)
Acc. to EN 60947

Type overview MDR 4S


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

MDR-4 DBA AFAA 040A060 XAA XXX


MDR-4 DAA AFAA 040A060 XAA XXX
MDR-4 DOA AFAA 040A060 XAA XXX
MDR-4 GBA AFAA 090A110 XAA XXX
MDR-4 GAA AFAA 090A110 XAA XXX
MDR-4 GOA AFAA 095A110 XAA XXX
MDR-4 HBA AFAA 135A160 XAA XXX
MDR-4 HAA AFAA 135A160 XAA XXX
MDR-4 HOA AFAA 135A160 XAA XXX
MDR-4 DBA BFAA 040A060 XAA XXX
MDR-4 DAA BFAA 040A060 XAA XXX
MDR-4 DOA.BFAA 040A060 XAA XXX
MDR-4 GBA AFAA 090A110 XAA XXX
MDR-4 GAA BFAA 090A110 XAA XXX
MDR-4 GOA BFAA 095A110 XAA XXX
MDR-4 HBA BFAA 135A160 XAA XXX
MDR-4 HAA BFAA 135A160 XAA XXX
MDR-4 HOA BFAA 135A160 XAA XXX

EA
EA
EA
EA
EA
EA
EA
EA
EA
-

1.5 - 6
1.5 - 6
1.5 - 6
4 - 11
4 - 11
4 - 11
6 - 16
6 - 16
6 - 16
1.5 - 6
1.5 - 6
1.5 - 6
4 - 11
4 - 11
4 - 11
6 - 16
6 - 16
6 - 16

G 1/4"
G 1/2"
G 1/2" + 1/4
G 1/4"
G 1/2"
G 1/2" + 1/4
G 1/4"
G 1/2"
G 1/2" + 1/4
G 1/4"
G 1/2"
G 1/2" + 1/4
G 1/4"
G 1/2"
G 1/2" + 1/4
G 1/4"
G 1/2"
G 1/2" + 1/4

420
420
420
420
420
420
420
420
420
420
420
420
420
420
420
420
420
420

212584
212591
212607
212614
212621
212638
212645
212652
212669
220084
220077
220121
204251
206194
227069
204244
220107
227076

Unloader valves and cable glands for retrofitting see Accessories!

Pressure switch MDR 4 SD


3-phase
Switching capacity 4.0 / 5.5 kW
Max. cut-out pressure 11 bar
With scale and transparent cover
3-pole (N.C.)
Acc. to EN 60947

Type overview MDR 4 SD


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

MDR-4 DAA BFDA 040A060 XAA XXX


MDR-4 DBA BFDA 040A060 XAA XXX
MDR-4 GAA BFDA 090A110 XAA XXX
Unloader valves and cable glands for retrofitting see Accessories!

1.5 - 6
1.5 - 6
4 - 11

Flange

Weight
in g

Part No.

1/2"
1/4"
1/2"

420
420
420

212737
212744
212751

www.condor-cpc.com

Page 3.21

Pressure switch MDR 4

Pressure switch MDR 4 SU


3-phase
Switching capacity 2.5 / 4.0 kW
Max. cut-out pressure 16 bar
With reversed function
3-pole (N.O.)
Acc. to EN 60947

Type Summary MDR 4 SU


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

MDR-4 DAA BFCA 040A060 XAA XXX


MDR-4 GAA BFCA 090A110 XAA XXX
MDR-4 HAA BFCA 090A110 XAA XXX

1.5 - 6
4 - 11
6 - 16

1/2"
1/2"
1/2"

420
420
420

212706
212713
212720

Unloader valves and cable glands for retrofitting see Accessories!

Technical Data MDR 4


Technical Data MDR 4 S / MDR 4 SD
acc. to EN 60947
Rated insulation voltage
Ui
Motor switching capacity
(AC 3) Ue=240 V (1~)
Motor switching capacity
(AC 3) Ue=230 V (3~)
Motor switching capacity
(AC 3) Ue=400 V (3~)
Motor switching capacity
(AC 3) Ue=500 V (3~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h

Technical Data MDR 4 S / MDR 4 SD


acc. to EN 60947
500 V
2.5 kW
4.0 kW
5.5 kW
5.5 kW
> 1 x 10

> 5 x 10

120

Max. mechanical cycles


Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz
Permissible medium temperature
Air
Permissible medium temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ..
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

Technical Data MDR 4 SU


acc. to EN 60947
Rated insulation voltage
Ui
Motor switching capacity
(AC 3) Ue=240 V (1~)
Motor switching capacity
(AC 3) Ue=230 V (3~)
Motor switching capacity
(AC 3) Ue=400 V (3~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz

Page 3.22

www.condor-cpc.com

600
20 A
> 35 bar
- 5...+ 80 C
+ 80 C
IP 44
2

2.5 / 2.5mm

2.5 / 2.5mm

Technical Data MDR 4 SU


acc. to EN 60947
500 V
1.5 kW
2.5 kW
4.0 kW
5

> 1 x 10
> 5 x 10

Permissible medium temperature


Air
Permissible medium temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1 ..
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

- 5...+ 80 C
+ 80 C
IP 44
2

2.5 / 2.5mm

2.5 / 2.5mm

120

Diaphragm media resistance MDR 4 ..


600
20 A
> 35 bar

Air, Water

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Pressure switch MDR 4

Dimensions MDR 4

Pressure switch MDR 4

Circuit Diagrams MDR 4

MDR 4 S

MDR 4 SD

MDR 4 SU

Accessories MDR 4
Order
reference

Weight
in g

Part No

90 with quick-connect for 6 mm plastic discharge tubes

25
25
15
15
15

201601
201625
255055
255062
201656

AEV 4S
AEV 4W
AEV 4Wi
AEV 4WS

Unloader valves for difficult motor starting conditions


With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or copper discharge tubes
90 with screw connection for 1/4" mm plastic or copper discharge tubes
90 with quick-connect for 6 mm plastic discharge tubes

25
15
15
15

201687
201694
255079
255086

WN
PG 11 G
PG 11 V
PG 11 Z
PG 11 ZK
PG 13.5 G
PG 13.5 V
PG 13.5 Z
PG 13.5 ZK

Cable glands
Grommet
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support
Conduits for mounting of cable glands (Inner thread)
Cable gland complete
With strain relief
With strain relief and cable support

6
6
12
12
12
6
12
12
12

200888
200895
200901
200925
200918
200963
200932
200956
200949

MW 4

Mounting bracket

65

230021

H4

Cover
Cover without rotary knob (Neutral version, without marking)

70

229469

Cover with rotary knob for manual On/Off (Neutral version, without marking)

70

229476

Cover without rotary knob for MDR 4 SD (transparent)

70

229483

EV 4
EV 4S
EV 4W
EV 4Wi
EV 4WS

Description
Unloader valves
With screw connection for 6 mm plastic or copper discharge tubes
With quick-connect for 6 mm plastic discharge tubes
90 with screw connection for 6 mm plastic or discharge copper tubes
90 with screw connection for 1/4" mm plastic or discharge copper tubes

(Cover MDR 4S)

H4S+EA
(Cover MDR 4S+EA)

H4SD
(Cover MDR 4SD)

www.condor-cpc.com

Page 3.23

Pressure switch MDR 4

Unloader valves / Delayed unloader valves

EV 4

EV 4S

AEV 4S

EV 2W / EV 4Wi

AEV 4W / AEV 4Wi

EV 4WS

AEV 4WS

Wall-mounting bracket / Cable glands MDR 4

MW 4

WN

PG .. G

PG .. V

PG .. Z

PG .. ZK

Dimensions, Accessories MDR 4

EV 4
Page 3.24

www.condor-cpc.com

EV 4 S

AEV 4 S

Pressure switch MDR 4

EV 4W / EV 4Wi
AEV 4W / AEV 4Wi

EV4 WS
AEV 4WS

Pressure Diagrams MDR 4

www.condor-cpc.com

Page 3.25

Pressure switch MDR 5

Pressure switch MDR 5


3-phase
Switching capacity 5.5 kW
Available with overload relay
Max. cut-out pressure 16 bar
3-pole (N.C.)
Acc. to EN 60947

Type overview MDR 5


Order reference

ON / OFF
buttons

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

MDR-5 CAA BAAA 015A030 XXX XXX


MDR-5 CAA AAAA 015A030 XXX XXX
MDR-5 COA BAAA 015A030 XXX XXX
MDR-5 COA AAAA 015A030 XXX XXX
MDR-5 EAA BAAA 070A080 XXX XXX
MDR-5 EAA AAAA 070A080 XXX XXX
MDR-5 EOA BAAA 070A080 XXX XXX
MDR-5 EOA AAAA 070A080 XXX XXX
MDR 5 GAA BAAA 090A110 XXX XXX
MDR-5 GAA AAAA 090A110 XXX XXX
MDR-5 GOA BAAA 090A110 XXX XXX
MDR-5 GOA AAAA 090A110 XXX XXX
MDR-5 HAA BAAA 130A160 XXX XXX
MDR-5 HAA AAAA 130A160 XXX XXX
MDR 5 HOA BAAA 130A160 XXX XXX
MDR-5 HOA AAAA 130A160 XXX XXX

K*
K*
K*
K*
K*
K*
K*
K*

1.5 - 5
1.5 - 5
1,5 - 5
1.5 - 5
2-8
2-8
2-8
2-8
2 - 11
2 - 11
2 - 11
2 - 11
2.5 - 16
2.5 - 16
2.5 - 16
2.5 - 16

G 1/2"
G 1/2"
G 1/2 + 1/4"
G 1/2 + 1/4"
G 1/2"
G 1/2"
G 1/2 + 1/4"
G 1/2 + 1/4"
G 1/2"
G 1/2"
G 1/2 + 1/4"
G 1/2 + 1/4"
G 1/2"
G 1/2"
G 1/2 + 1/4"
G 1/2 + 1/4"

820
860
860
900
820
860
860
900
820
860
860
900
820
860
860
900

212850
212867
212874
212881
212898
212904
212911
212928
212935
212942
212959
212966
212973
212980
212997
213000

* For these switches, a thermal, 3-pole overload relay has to be ordered separately,
otherwise the ON/OFF switching mechanism will not function.
Unloader valves and cable glands for retrofitting see Accessories!

Technical Data
Technical Data MDR 5 acc. to EN 60947
Rated insulation voltage
Ui
Motor switching capacity
(AC 3) Ue=240 V (1~)
Motor switching capacity
(AC 3) Ue=230 V (3~)
Motor switching capacity
(AC 3) Ue=400 V (3~)
Motor switching capacity
(AC 3) Ue=500 V (1~)
Electrical life (AC 3)
Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC

Technical Data MDR 5 acc. to EN 60947


500 V
2.5 kW
4.0 kW
5.5 kW
4.0 kW

> 1 x 10

> 5 x 10

Bursting strength Pz
Permissible medium temperature
Air
Permissible medium temperature
Water
Degree of Protection
acc. to EN 60529
Conductor cross-section 1
fine stranded cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

> 40 bar
- 5...+ 80 C
+ 80 C
IP 54
2

2.5 / 2.5mm

4 / 4mm

Diaphragm media resistance MDR 5


120
600
25 A

Acetylene, Gasoline, Butane, Diesel,


Natural gas, Petroleum, Ethylene glycol,
Glycerol, Fuel oil, Urine, Carbon dioxide,
Carbonic acid, Air, Mineral oils, Vegetable
oil, Propane, Silicon oil, Nitrogen, Synthetic
oils, Water, Distilled water, Hydrogen, Sea
water, Water steam

resistant

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Page 3.26

www.condor-cpc.com

Pressure switch MDR 5

Dimensions MDR 5

Pressure switch MDR-5

Circuit Diagrams MDR 5

MDR 5

MDR 5K R5

Accessories MDR 5
Order
reference

Description

Weight
in g

Part No.

30

201878

EV 5i
EV 5E
EV 5Ei

Unloader valves
With screw connection for 6 mm plastic or copper discharge tubes, screw connection
for vent port
With screw connection for 1/4" plastic or copper discharge tubes
With screw connection for 6 mm plastic or copper discharge tubes
With screw connection for 1/4" plastic or copper discharge tubes

30
25
25

201885
201892
201908

AEV 5
AEV 5i

Delayed unloader valves


With screw connection for 6 mm plastic or copper discharge tubes
With screw connection for 1/4" plastic or copper discharge tubes

25
25

201939
201946

WN 5
PG 16 V-5
PG 16 Z-5
PG 16 ZK-5
PG 16/13.5 Z
PG 16/13.5 ZK
PG 16/11 V-5

Cable glands
Grommet
Cable glands complete
With strain relief
With strain relief and cable support
Reduced to PG 13.5 with strain relief
Reduced to PG 13.5 with strain relief and cable support
Reduced to PG 11

6
12
12
12
12
12
12

201953
201960
201977
201984
202004
202011
201991

MW 5

Mounting bracket

120

230045

Cover
Cover without push-buttons

130

230052

150

217527

150
150
150
150
150
150
150

202028
202035
202042
202059
202066
202073
202080

EV 5

H5
(Cover 5)
H5-K (Cover
5+K)

R 5/1.5
R 5/2.45
R 5/4.2
R 5/7.0
R 5/10.3
R 5/14.0
R 5/18.0

Cover with On/Off push-buttons (Only functions together with the thermal R5 overload
relay)
Thermal, 3-pole overload relay
0.86 1.50 A
1.50 2.45 A
2.40 4.20 A
4.00 7.00 A
6.10 10.3 A
9.00 14.0 A
11.0 18.0 A

www.condor-cpc.com

Page 3.27

Pressure switch MDR 5

Unloader valves / Unloader valves for difficult motor starting conditions

EV 5, EV 5i

EV 5E / EV 5 Ei

AEV 5 / AEV 5i

Cable glands MDR 5

WN 5

PG 16 V-5

PG 16 Z-5

PG 16 ZK-5

PG 16/11 V-5

Accessories, Miscellaneous

MW 5

H5

H5-K

R 5/ ..

Dimensions, Accessories

EV 5, EV 5i

Page 3.28

www.condor-cpc.com

EV 5E / EV 5 Ei

AEV 5 / AEV 5i

Pressure switch MDR 5

Tripping curves R5 (average)

Pressure Diagrams MDR 5

www.condor-cpc.com

Page 3.29

Page 3.30

www.condor-cpc.com

Control pressure switch, general overview

Control pressure switches

Page
4.02

MDR - F

Pressure ranges up to 250 bar


Ample wiring room
Simple calibration
High repeatability
1 SPDT
Acc. to EN 60947
Ample variety of models

MDR 43

Pressure ranges up to 16 bar


Transparent cover
1 N.O. + 1 N.C.
Acc. to EN 60947

4.11

MDR 53

Pressure ranges up to 16 bar


Ample wiring room
High switching accuracy
1 PSDT
Acc. to EN 60947
UL / CSA-approval

4.13

FF 142

Pressure ranges up to 40 bar


Ample wiring room
Simple calibration
2 SPDT's
Acc. to EN 60947
Insulate and die-cast

4.16

PS 1

Pressure ranges up to 31 bar


Simple calibration
1 SPDT
Acc. to EN 60947
UL / CSA-approval
Also for vacuum applications

4.20

www.condor-cpc.com

Page 4.01

Pressure switch MDR - F

Control pressure switch MDR - F


Pressure ranges up to 250 bars
Ample wiring room
Simple calibration
High repeatability
1 SPDT
Acc. to EN 60947
Large variety of models
Applications:
Compressors, pumps, construction machines,
fire-fighting equipment, oil pressure control

Application
The Condor pressure switch series MDR-F can be
universally used and are suitable for:
- Monitoring and controlling the pressure of
liquids or gaseous media in pipelines, tanks,
vats, pressure vessels and apparatus.
- Tasks in process control, cooling, pneumatics
and hydraulics.
- Pressure monitoring of cooling circuits and
lubrication systems on various types of
machinery.
- Automatic switching of pump and compressor
motors for supplying water to dwellings,
booster pumps, fire-fighting equipment and on
compressed air systems.

Mode of operation:
The pressure of the monitored medium operates
against a diaphragm, bellows or a plunger all of
which have different media resistance. Switching
operation is carried out with the use of a micro
switch ensuring flutter-free switching.

When the pressure reaches the upper switching


point, the micro switch contacts change position.
In normal cases e.g. a connected motor is
switched off (up to 550 watts direct or using
additional switches like a contactor etc.). Should
the pressure fall below the lower switch point,
then the micro switch contact returns to its default
position and the motor is switched on.
The upper and lower switching points can be set
independently using a screw driver. Both
switching points can be read off the scale.
Pressure connection, pressure sensing element
and electrical connections are all fitted on to a diecast aluminum base. The sealable transparent,
polycarbonate cover protects the scales and
switch against environmental effects.
Standard scope of delivery: rubber grommets
MDR-F..H Die-cast aluminum flange
MDR-F..Y Plastic flange (in particular for use in
water technology applications)

Besides the standard types with Perbunan diaphragms, the following new types are available:
- Pressure switch with stainless steel pressure sensing element e.g. for liquid fuels, oils up to 200C
etc.
- High pressure switch with plastic plunger press. sensing element with stainless steel connection up to
250 bar
- Pressure switch with manual reset function and die-cast aluminum flange for oil, water and air etc.
- Pressure switch with Viton diaphragm and die-cast aluminum flange for increased media resistance
The MDR-F pressure switch program is being constantly expanded. Along with the VdS approval, the
following approvals are being presently processed: Atex, Germanischer Lloyd etc. The VdS version will be
available no later than beginning 2008.

Page 4.02

www.condor-cpc.com

Pressure switch MDR - F


Type overview MDR-F .. H (G) suffix G for gold-flashed contacts
Pressure switch with Perbunan diaphragm and die-cast aluminum flange for oil, water and air etc.
Connection: H G 3/8 inner thread DIN ISO 228/I, VDE 0660, IEC 337-1, IEC 553-1
Industrial cage clamp version
Order
reference
MDR-F 2H
MDR-F 2HG
MDR-F 4H
MDR-F 4HG
MDR-F 8H
MDR-F 8HG
MDR-F 10H
MDR-F 10HG
MDR-F 16H
MDR-F 16HG
MDR-F 32H
MDR-F 32HG

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 2 HAA AAA A 005A015


MDR-F 2 HAA ABA A 005A015
MDR-F 4 HAA AAA A 010A030
MDR-F 4 HAA ABA A 010A030
MDR-F 8 HAA AAA A 020A060
MDR-F 8 HAA ABA A 020A060
MDR-F 10 HAA AAA A 040A050
MDR-F 10 HAA ABA A 040A050
MDR-F 16 HAA AAA A 040A120
MDR-F 16 HAA ABA A 040A120
MDR-F 32 HAA AAA A 100A200
MDR-F 32 HAA ABA A 100A200

0.04 1,89 bar


0.04 1,89 bar
0.07 3,75 bar
0.07 3,75 bar
0.2 7,5 bar
0.2 7,5 bar
0.3 9,2 bar
0.3 9,2 bar
0.4 15 bar
0.4 15 bar
0.8 30 bar
0.8 30 bar

Smallest
pressure
diff. (bar)*
0.07
0.07
0.15
0.15
0.3
0.3
0.4
0.4
0.6
0.6
1.2
1.2

0.11
0.11
0.25
0.25
0.5
0.5
0.8
0.8
1.0
1.0
2.0
2.0

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.11 2 bar
0.22 4 bar
0.22 4 bar
0.5 8 bar
0.5 8 bar
0.7 10 bar
0.7 10 bar
1 16 bar
1 16 bar
2 32 bar
2 32 bar

252511
252528
252535
252542
252559
252566
252573
252580
252597
252603
252610
252627

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.11 2 bar
0.22 4 bar
0.22 4 bar
0.5 8 bar
0.5 8 bar
0.7 10 bar
0.7 10 bar
1 16 bar
1 16 bar
2 32 bar
2 32 bar

253501
253518
253525
253532
253549
253556
253563
253570
253587
253594
253600
253617

Industrial screw clamp version


Order
reference
MDR-F 2H
MDR-F 2HG
MDR-F 4H
MDR-F 4HG
MDR-F 8H
MDR-F 8HG
MDR-F 10H
MDR-F 10HG
MDR-F 16H
MDR-F 16HG
MDR-F 32H
MDR-F 32HG

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 2 HAA SAA A 005A015


MDR-F 2 HAA SBA A 005A015
MDR-F 4 HAA SAA A 010A030
MDR-F 4 HAA SBA A 010A030
MDR-F 8 HAA SAA A 020A060
MDR-F 8 HAA SBA A 020A060
MDR-F 10 HAA SAA A 040A050
MDR-F 10 HAA SBA A 040A050
MDR-F 16 HAA SAA A 040A120
MDR-F 16 HAA SBA A 040A120
MDR-F 32 HAA SAA A 100A200
MDR-F 32 HAA SBA A 100A200

0.04 1.89 bar


0.04 1.89 bar
0.07 3.75 bar
0.07 3.75 bar
0.2 7.5 bar
0.2 7.5 bar
0.3 9.2 bar
0.3 9.2 bar
0.4 15 bar
0.4 15 bar
0.8 30 bar
0.8 30 bar

Smallest
pressure
diff. (bar)*
0.07
0.07
0.15
0.15
0.3
0.3
0.4
0.4
0.6
0.6
1.2
1.2

0.11
0.11
0.25
0.25
0.5
0.5
0.8
0.8
1.0
1.0
2.0
2.0

* lower upper end of range

Type overview MDR-F .. Y (G) suffix G for gold-flashed contacts


Pressure switch with Perbunan diaphragm and plastic flange e.g. for demineralized water
Connection: Y G 3/8 inner thread DIN ISO 228/I, VDE 0660, IEC 337-1, IEC 553-1
Industrial cage clamp version
Order
reference
MDR-F 2Y
MDR-F 2YG
MDR-F 4Y
MDR-F 4YG
MDR-F 8Y
MDR-F 8YG
MDR-F 10Y
MDR-F 10YG
MDR-F 16Y
MDR-F 16YG

Matchcode

MDR-F 2 YAA AAA A 005A015


MDR-F 2 YAA ABA A 005A015
MDR-F 4 YAA AAA A 010A030
MDR-F 4 YAA ABA A 010A030
MDR-F 8 YAA AAA A 020A060
MDR-F 8 YAA ABA A 020A060
MDR-F 10 YAA AAA A 040A050
MDR-F 10 YAA ABA A 040A050
MDR-F 16 YAA AAA A 040A120
MDR-F 16 YAA ABA A 040A120

Adjustable cutin pressure


(bar)
0.04 1.89 bar
0.04 1.89 bar
0.07 3.75 bar
0.07 3.75 bar
0.2 7.5 bar
0.2 7.5 bar
0.3 9.2 bar
0.3 9.2 bar
0.4 15 bar
0.4 15 bar

Smallest
pressure
diff. (bar)*
0.07
0.07
0.15
0.15
0.3
0.3
0.4
0.4
0.6
0.6

0.11
0.11
0.25
0.25
0.5
0.5
0.8
0.8
1.0
1.0

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.11 2 bar
0.22 4 bar
0.22 4 bar
0.5 8 bar
0.5 8 bar
0.7 10 bar
0.7 10 bar
1 16 bar
1 16 bar

252634
252641
252658
252665
252672
252689
252696
252702
252719
252726

www.condor-cpc.com

Page 4.03

Pressure switch MDR - F


Industrial screw clamp version
Order
reference
MDR-F 2Y
MDR-F 2YG
MDR-F 4Y
MDR-F 4YG
MDR-F 8Y
MDR-F 8YG
MDR-F 10Y
MDR-F 10YG
MDR-F 16Y
MDR-F 16YG

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 2 YAA SAA A 005A015


MDR-F 2 YAA SBA A 005A015
MDR-F 4 YAA SAA A 010A030
MDR-F 4 YAA SBA A 010A030
MDR-F 8 YAA SAA A 020A060
MDR-F 8 YAA SBA A 020A060
MDR-F 10 YAA SAA A 040A050
MDR-F 10 YAA SBA A 040A050
MDR-F 16 YAA SAA A 040A120
MDR-F 16 YAA SBA A 040A120

0.04 1.89 bar


0.04 1.89 bar
0.07 3.75 bar
0.07 3.75 bar
0.2 7.5 bar
0.2 7.5 bar
0.3 9.2 bar
0.3 9.2 bar
0.4 15 bar
0.4 15 bar

Smallest
pressure
diff. (bar)*
0.07
0.07
0.15
0.15
0.3
0.3
0.4
0.4
0.6
0.6

0.11
0.11
0.25
0.25
0.5
0.5
0.8
0.8
1.0
1.0

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.11 2 bar
0.22 4 bar
0.22 4 bar
0.5 8 bar
0.5 8 bar
0.7 10 bar
0.7 10 bar
1 16 bar
1 16 bar

253624
253631
253648
253655
253662
253679
253686
253693
253709
253716

* lower upper end of range

Type overview MDR-F .. HE (G) suffix G for gold-flashed contacts


Pressure switch with stainless steel press. sensing element e.g. for liquid fuels, oils up to 200C etc.
Connection: HE G 1/4 inner thread DIN ISO 228/I, VDE 0660, IEC 337-1, IEC 553-1
Industrial cage clamp version
Order
reference
MDR-F 12HE
MDR-F 12HEG
MDR-F 30HE
MDR-F 30HEG

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 12 HEC AAA A 060A070


MDR-F 12 HEC ABA A 060A070
MDR-F 30 HEC AAA A 160A200
MDR-F 30 HEC ABA A 160A200

0.5 11.2 bar


0.5 11.2 bar
1 26.4 bar
1 26.4 bar

Smallest
pressure
diff. (bar)*
0.5
0.5
1.8
1.8

0.8
0.8
3.6
3.6

Adjustable cut-out
pressure (bar)

Part No.

1 12 bar
1 12 bar
2.8 30 bar
2.8 30 bar

252733
252740
252757
252764

Adjustable cut-out
pressure (bar)

Part No.

1 12 bar
1 12 bar
2.8 30 bar
2.8 30 bar

253723
253730
253747
253754

Industrial screw clamp version


Order
reference
MDR-F 12HE
MDR-F 12HEG
MDR-F 30HE
MDR-F 30HEG

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 12 HEC SAA A 060A070


MDR-F 12 HEC SBA A 060A070
MDR-F 30 HEC SAA A 160A200
MDR-F 30 HEC SBA A 160A200

0.5 11.2 bar


0.5 11.2 bar
1 26.4 bar
1 26.4 bar

Smallest
pressure
diff. (bar)*
0.5
0.5
1.8
1.8

0.8
0.8
3.6
3.6

* lower upper end of range

Type overview MDR-F .. HH (G) suffix G for gold-flashed contacts


High pressure switch with plastic plunger press. sensing element with stainless steel connection up to
250 bar
Connection HH 3/8 inner thread DIN ISO 228/I, VDE 0660, IEC 337-1, IEC 553-1
Industrial cage clamp version
Order
reference
MDR-F 60HH
MDR-F 60HHG
MDR-F 120HH
MDR-F 120HHG
MDR-F 250HH
MDR-F 250HHG

Page 4.04

Matchcode

MDR-F 60 HHC AAA A 200A400


MDR-F 60 HHC ABA A 200A400
MDR-F 120 HHC AAA A 200A800
MDR-F 120 HHC ABA A 200A800
MDR-F 250 HHC AAA A 100F200
MDR-F 250 HHC ABA A 100F200

www.condor-cpc.com

Adjustable cutin pressure


(bar)
4 52 bar
4 52 bar
8 104 bar
8 104 bar
14 226 bar
14 226 bar

Smallest
pressure
diff. (bar)*
4
4
8
8
12
12

8
8
16
16
24
24

Adjustable cut-out
pressure (bar)

Part No.

8 60 bar
8 60 bar
16 120 bar
16 120 bar
26 250 bar
26 250 bar

252771
252788
252795
252804
252818
252825

Pressure switch MDR - F

Industrial screw clamp version


Order
reference
MDR-F 60HH
MDR-F 60HHG
MDR-F 120HH
MDR-F 120HHG
MDR-F 250HH
MDR-F 250HHG

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 60 HHC SAA A 200A400


MDR-F 60 HHC SBA A 200A400
MDR-F 120 HHC SAA A 200A800
MDR-F 120 HHC SBA A 200A800
MDR-F 250 HHC SAA A 100F200
MDR-F 250 HHC SBA A 100F200

4 52 bar
4 52 bar
8 104 bar
8 104 bar
14 226 bar
14 226 bar

Smallest
pressure
diff. (bar)*
4
4
8
8
12
12

8
8
16
16
24
24

Adjustable cut-out
pressure (bar)

Part No.

8 60 bar
8 60 bar
16 120 bar
16 120 bar
26 250 bar
26 250 bar

253761
253778
253785
253792
253808
253815

* lower upper end of range

Type overview MDR-F .. Reset function (Hmin / Hmax and Htro)


Pressure switch with reset function and die-cast aluminum flange for oil, water and air etc.
Connection: H G 3/8 inner thread DIN ISO 228/I, VDE 0660, IEC 337-1, IEC 553-1
MDR-F .. Hmax (SPDT with manual reset max.)
When pressure rises above the upper setting value, contact 11-12 opens and contact 11-14 closes and latches. When the
pressure falls bellow the upper setting value, the contact can be released with the manual reset button.

MDR-F .. Hmin (SPDT with manual reset min.)


After pressure rises above the lower setting value, the function is activated by pressing the manual reset button. When
the pressure falls, contact 11-12 closes and opens contact 11-14 when reaching the lower cut-in value. Since the upper
switching point (cut-out pressure) of the reset pressure switch must lie above the maximum cut-out pressure of the
apparatus, the switching state remains until the manual reset button is pressed again.

MDR-F .. Htro (SPDT with manual reset as run-dry protection)


The manual reset button must be held when the pressure rises beyond the switching point to be monitored or pressed
once at the current pressure. When the pressure falls, contact 11-12 closes and opens contact 11-14 when the
monitored pressure point is reached. When the pressure rises above the adjusted value, contact 11-12 opens and closes
contact 11-14 again automatically.
Industrial cage clamp version
Order
reference
MDR-F 2Hmax
MDR-F 4Hmax
MDR-F 8Hmax
MDR-F 10Hmax
MDR-F 16Hmax
MDR-F 32Hmax
MDR-F 2Hmin
MDR-F 4Hmin
MDR-F 8Hmin
MDR-F 10Hmin
MDR-F 16Hmin
MDR-F 32Hmin
MDR-F 2Htro
MDR-F 4Htro
MDR-F 8Htro
MDR-F 10Htro
MDR-F 16Htro
MDR-F 32Htro

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 2 HAA AAH A 005A015


MDR-F 4 HAA AAH A 010A030
MDR-F 8 HAA AAH A 020A060
MDR-F 10 HAA AAH A 040A050
MDR-F 16 HAA AAH A 040A120
MDR-F 32 HAA AAH A 100A200
MDR-F 2 HAA AAL A 005A015
MDR-F 4 HAA AAL A 010A030
MDR-F 8 HAA AAL A 020A060
MDR-F 10 HAA AAL A 040A050
MDR-F 16 HAA AAL A 040A120
MDR-F 32 HAA AAL A 100A200
MDR-F 2 HAA AAG A 005A015
MDR-F 4 HAA AAG A 010A030
MDR-F 8 HAA AAG A 020A060
MDR-F 10 HAA AAG A 040A050
MDR-F 16 HAA AAG A 040A120
MDR-F 32 HAA AAG A 100A200

0.04 1.89 bar


0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar
0.04 1.89 bar
0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar
0.04 1.89 bar
0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar

Smallest
pressure
diff. (bar)*
0.07
0.15
0.3
0.4
0.6
1.2
0.07
0.15
0.3
0.4
0.6
1.2
0.07
0.15
0.3
0.4
0.6
1.2

0.11
0.25
0.5
0.8
1.0
2.0
0.11
0.25
0.5
0.8
1.0
2.0
0.11
0.25
0.5
0.8
1.0
2.0

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar
0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar
0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar

253075
253082
253099
253105
253112
253129
253136
253143
253150
253167
253174
253181
253433
253440
253457
253464
253471
253488

* lower upper end of range

www.condor-cpc.com

Page 4.05

Pressure switch MDR - F

Industrial screw clamp version


Order
reference
MDR-F 2Hmax
MDR-F 4Hmax
MDR-F 8Hmax
MDR-F 10Hmax
MDR-F 16Hmax
MDR-F 32Hmax
MDR-F 2Hmin
MDR-F 4Hmin
MDR-F 8Hmin
MDR-F 10Hmin
MDR-F 16Hmin
MDR-F 32Hmin
MDR-F 2Htro
MDR-F 4Htro
MDR-F 8Htro
MDR-F 10Htro
MDR-F 16Htro
MDR-F 32Htro

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 2 HAA SAH A 005A015


MDR-F 4 HAA SAH A 010A030
MDR-F 8 HAA SAH A 020A060
MDR-F 10 HAA SAH A 040A050
MDR-F 16 HAA SAH A 040A120
MDR-F 32 HAA SAH A 100A200
MDR-F 2 HAA SAL A 005A015
MDR-F 4 HAA SAL A 010A030
MDR-F 8 HAA SAL A 020A060
MDR-F 10 HAA SAL A 040A050
MDR-F 16 HAA SAL A 040A120
MDR-F 32 HAA SAL A 100A200
MDR-F 2 HAA SAG A 005A015
MDR-F 4 HAA SAG A 010A030
MDR-F 8 HAA SAG A 020A060
MDR-F 10 HAA SAG A 040A050
MDR-F 16 HAA SAG A 040A120
MDR-F 32 HAA SAG A 100A200

0.04 1.89 bar


0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar
0.04 1.89 bar
0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar
0.04 1.89 bar
0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar

Smallest
pressure
diff. (bar)*
0.07
0.15
0.3
0.4
0.6
1.2
0.07
0.15
0.3
0.4
0.6
1.2
0.07
0.15
0.3
0.4
0.6
1.2

0.11
0.25
0.5
0.8
1.0
2.0
0.11
0.25
0.5
0.8
1.0
2.0
0.11
0.25
0.5
0.8
1.0
2.0

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar
0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar
0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar

254065
254072
254089
254096
254102
254119
254126
254133
254140
254157
254164
254171
254188
254195
254201
254218
254225
254232

* lower upper end of range

Additional MDR-F pressure switch versions .. Reset function are available on request (e.g. as
stainless steel bellows version, with gold-flashed contacts, as high pressure switch etc.).

Type overview MDR-F .. HV


Pressure switch with Viton diaphragm and die-cast aluminum flange for enhanced media resistance
Connection: H G 3/8 inner thread DIN ISO 228/I, VDE 0660, IEC 337-1, IEC 553-1
Industrial cage clamp style
Order
reference
MDR-F 2HV
MDR-F 4HV
MDR-F 8HV
MDR-F10 HV
MDR-F 16HV
MDR-F 32HV

Matchcode

Adjustable cutin pressure


(bar)

MDR-F 2 HAV AAA A 005A015


MDR-F 4 HAV AAA A 010A030
MDR-F 8 HAV AAA A 020A060
MDR-F 10 HAV AAA A 040A050
MDR-F 16 HAV AAA A 040A120
MDR-F 32 HAV AAA A 100A200

0.04 1.89 bar


0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar

Smallest
pressure
diff. (bar)*
0.07
0.15
0.3
0.4
0.6
1.2

0.11
0.25
0.5
0.8
1.0
2.0

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar

252894
252900
252917
252924
252931
252948

Adjustable cut-out
pressure (bar)

Part No.

0.11 2 bar
0.22 4 bar
0.5 8 bar
0.7 10 bar
1 16 bar
2 32 bar

253884
253891
253907
253914
253921
253938

Industrial screw clamp version


Order
reference
MDR-F 2HV
MDR-F 4HV
MDR-F 8HV
MDR-F10 HV
MDR-F 16HV
MDR-F 32HV

Matchcode

MDR-F 2 HAV SAA A 005A015


MDR-F 4 HAV SAA A 010A030
MDR-F 8 HAV SAA A 020A060
MDR-F 10 HAV SAA A 040A050
MDR-F 16 HAV SAA A 040A120
MDR-F 32 HAV SAA A 100A200

Adjustable cutin pressure


(bar)
0.04 1.89 bar
0.07 3.75 bar
0.2 7.5 bar
0.3 9.2 bar
0.4 15 bar
0.8 30 bar

Smallest
pressure
diff. (bar)*
0.07
0.15
0.3
0.4
0.6
1.2

0.11
0.25
0.5
0.8
1.0
2.0

* lower upper end of range

Additional pressure switch versions MDR-F .. HV are available on request (e.g. as manual reset
pressure switches, with gold-flashed contacts, with plastic flange etc.).

Page 4.06

www.condor-cpc.com

Pressure switch MDR - F

Technical data MDR-F


Technical data MDR-F standard version
Rated operational current Ie AC 1
Ue=240 V (1~)
Rated operational current Ie AC 15
Ue=240 V (1~)
Rated operational current Ie DC 13
Ue=240 V (1~)
Permissible motor rating
1~ 230 V

Technical data MDR-F..(G) gold-flashed contact


10 A
4A

400 mA
12 VA

0.1 A
0.55 kW

Technical data MDR-F


Vibration resistance
10 up to 1000 Hz
Degree of protection acc. to DIN 40
050/IEC 529
With rubber grommets
Degree of protection acc. to DIN 40
050/IEC 529
With cable glands M20
Ambient temperature range

Rated operational current Ie


Ue=30 V (1~)
Permissible motor rating
1~ 30 V

Technical data MDR-F


4g
IP 54

IP 65

Perm. media temperature:


MDR-F..H / HH
MDR-F..HV
MDR-F..HE
MDR-F..Y
Repeatability

+ 70 C
+ 130 C
+ 200 C
+ 50 C
<2% FS

- 20 C .. + 70 C

Cross-sections
Cage clamp (without cable end sleeve)
Cross-sections
Screw clamp

1.5 mm
2.5 mm

Media resistance MDR-F..


Media resistance MDR-F..H / MDR-F..Y
Perbunan diaphragm
Acetylene, Gasoline, Butane, Diesel,
Natural gas, Petroleum, Ethylene glycol,
Glycerol, Fuel oil, Urine, Carbon dioxide,
Carbonic acid, Air, Mineral oils,
Vegetable oil, Propane, Silicon oil,
Nitrogen, Synthetic oils, Water, Distilled
water, Hydrogen, Sea water, Steam

resistant

Media resistance MDR-F..HH


Polyacetal (High pressure version)
Acetylene, Gasoline, Butane, Diesel,
Natural gas, Petroleum, Ethylene glycol,
Glycerol, Fuel oil, Carbon dioxide,
Carbonic acid, Air, Propane, Nitrogen,
Water, Distilled water, Hydrogen, Sea
water

Media resistance MDR-F..HV


Viton diaphragm
Acetylene,
Ammonia-25%,
Gasoline,
Benzene,
Butane,
Chlorine,
Diesel,
Dimenthylbenzene,
Natural
gas,
Petroleum, Vinegar-25%, Ethylene glycol,
Glycerol, Fuel oil, Urine, Carbon dioxide,
Carbonic acid, Cooling liquid, Air, Methyl
chloride,
Mineral
oils,
Ozone,
Perchlorethylene, Vegetable oil, Propane,
Oxygen, Silicon oil, Nitrogen, Toluene,
Trichlorethene, Water, Distilled water,
Hydrogen, Sea water, Water steam

resistant

Media resistance MDR-F..HE


Stainless steel bellows
resistant

Acetone,
Acetylene,
Ammonia-100%,
Gasoline, Benzene, Butane, Butyl acetate,
Butyl alcohol, Diesel, Dimenthylbenzene,
Natural gas, Petroleum, Ethylene glycol,
Ethyl acetate, Glycerol, Fuel oil, Carbon
dioxide, Carbonic acid, Cooling liquid, Air,
Methyl chloride, Mineral oils, Ozone,
Perchlorethylene, Vegetable oil, Phenolic
acid, Propane, Oxygen, Protective gas,
Sulphur dioxide, Nitrogen, Synthetic oils,
Toluene, Trichlorethene, Water, Distilled
water, Hydrogen, Sea water, Water steam

resistant

A detailed overview of diaphragm media resistance for all pressure switches can be found in the table on page 2.11

www.condor-cpc.com

Page 4.07

Pressure switch MDR - F

Dimensions MDR - F

Pressure switch MDR F..H / Y / HV

Pressure switch MDR F.. HH / HE

Circuit diagram MDR-F

For special applications e.g. VdS, individual circuits are possible due to the use of integrated PCB's
(as default, contacts A and B are bridged)

Accessories MDR - F
Order
reference

Description

Weight
in g

Part No.

MDR-F M20

Cable glands
Cable gland M20

35

254249

MDR-F D-32
MDR-F D+32

Throttle
MDR-F up to 32 bar
MDR-F as of 32 bar

1
2

254256
254263

MDR-F Cover
MDR-F Cover R

Covers
MDR-F Cover, transparent, Standard
MDR-F Cover, transparent, for manual reset

90
90

254270
254287

MDR-F RT-1

Reset push-button
Reset push-buttons for mounting on cover R

25

254294

Additional accessories (e.g. pressure connectors) on demand

Page 4.08

www.condor-cpc.com

Pressure switch MDR - F

Pressure diagrams MDR-F

www.condor-cpc.com

Page 4.09

Druckschalter MDR - F

Pressure diagrams MDR-F

Page 4.10

www.condor-cpc.com

Druckschalter MDR 43

Control pressure switch MDR 43


Max. cut-out pressure 16 bar
Transparent cover
1 N.C. + 1 N.O.
Acc. to EN 60947

Type overview MDR 43


Order reference

ON / OFF
Rotary knob

Pressure range
POFF in bar

Flange

Weight
in g

Part No.

0.5 - 3
0.5 - 3
2.5 - 6
2.5 - 6
5 - 11
5 - 11
8 - 16
8 - 16

G 1/2"
G 1/4"
G 1/2"
G 1/4"
G 1/2"
G 1/4"
G 1/2"
G 1/4"

420
420
420
420
420
420
420
420

212775
212782
212799
212805
212812
217829
217836
219843

MDR-43 BAA BAAA xxxA020 XAA XXX


MDR-43 BBA BAAA xxxA020 XAA XXX
MDR-43 DAA BAAA xxxA040 XAA XXX
MDR-43 DBA BAAA xxxA040 XAA XXX
MDR-43 GAA BAAA xxxA090 XAA XXX
MDR-43 GBA BAAA xxxA090 XAA XXX
MDR-43 HAA BAAA xxxA120 XAA XXX
MDR-43 HBA BAAA xxxA120 XAA XXX
Cut-in pressure is
tightest possible
pressure differential

The cut-out pressure is preset

Cable glands for retrofit assembly to be ordered separately, see Accessories!

Technical Data MDR 43


Technical Data MDR 43 acc. to EN 60947
Rated insulation voltage Ui
Rated operating current Ie(AC 15)
Rated insulation voltage Ue(AC 15)

Electrical life (AC 3)


Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operational current Ie
at 240 V AC
Bursting strength Pz

Technical Data MDR 43 acc. to EN 60947


500 V
8A
250 V

> 1.5 x 105

Permissible medium temperature


Air
Permissible medium temperature
Water
Conductor cross-section 1 ..
flexible cable 1 x / 2 x
Conductor cross-section 1
rigid cable 1 x / 2 x

- 5...+ 80 C
+ 80 C
2.5 / 2.5mm2
2.5 / 2.5mm2

> 1 x 106

Diaphragm media resistance MDR 43


120

600
10 A

resistant
Acetylene, Butane, Natural gas, Petroleum,
Vinegar 25 %, Glycerol, Carbon dioxide, Air,
Propane, Sulphur dioxide, Silicon oil, Water,
Distilled water, Hydrogen, Sea water
A detailed overview of diaphragm media resistance for all
pressure switches can be found in the table on page 2.11

> 60 bar

Dimensions / Circuit Diagrams MDR 43

Pressure switch MDR 43


www.condor-cpc.com

Page 4.11

Control pressure switch MDR 43


Accessories MDR 43
Order
reference

Description

Weight
in g

Part No.

WN
PG 11 G
PG 11 V
PG 11 Z
PG 11 ZK
PG 13,5 G
PG 13,5 V
PG 13,5 Z
PG 13,5 ZK

Cable glands
Grommet
Conduits for mounting cable glands (inner thread)
Cable glands complete
With strain relief
With strain relief and cable support
Conduits for mounting cable glands (inner thread)
Cable glands complete
With strain relief
With strain relief and cable support

6
6
12
12
12
6
12
12
12

200888
200895
200901
200925
200918
200963
200932
200956
200949

MW 4

Mounting bracket

65

230021

H43

Cover
Cover (Transparent)

70

230038

(Cover MDR 43)

Wall-mounting bracket / Cable glands MDR 43

MW 4

WN

PG .. G

Pressure Diagrams MDR 43

Page 4.12

www.condor-cpc.com

PG .. V

PG .. Z

PG .. ZK

Control pressure switch MDR 53


Control pressure switch MDR 53
Max. cut-out pressure 16 bar
Ample wiring room
High switching accuracy
1 SPDT
Acc. to EN 60947
UL / CSA-approval

Type overview MDR 53


Order reference
MDR-53 EAA BAAA 075A080 XAA XXX
MDR-53 GAA BAAA xxxA110 XAA XXX*
MDR-53 HAA BAAA 155A160 XAA XXX
MDR-53 NAA BAAA xxxA030 XAA XXX**
MDR-53 OAA BAAA xxxA080 XAA XXX**

ON / OFF

Pressure range
POFF in bar

Flange

Weight
in g

Part No

0.5 - 8
6 - 11
6 - 16
up to 3
up to 8

G 1/2"
G 1/2"
G 1/2"
G 1/2"
G 1/2"

740
780
780
740
740

213079
216919
213086
213130
213147

* xxx = Cut-out pressure is preset, cut-in pressure is the tightest possible pressure differential.
** xxx = Cut-out pressure is preset, cut-in pressure is the tightest possible pressure differential and pressure-resistant up to 25 bar, SOType.
A screw plug is also supplied.
Cable glands for retrofit assembly to be ordered separately see Accessories!

Technical Data MDR 53


Technical Data MDR 53 acc. to EN 60947
Rated insulation voltage Ui
Rated operational current Ie(AC 15)

Technical Data MDR 53 acc. to EN 60947


500 V
8A

Rated insulation voltage Ue


(AC 15)

250 V

Electrical life (AC 3)


Cycles
Mechanical life
Cycles
Max. electrical cycles
Cycles/h
Max. mechanical cycles
Cycles/h
Rated operating current Ie

> 2 x 105

Bursting strength Pz

> 40 bar

Rated operating current Ie


at 240 V AC

Permissible media temperature


Water
Protection
acc. to EN 60529

+ 80 C
IP 54
2

Conductor cross-section 1 ..
flexible cable 1 x / 2 x

2.5 / 2.5mm

Conductor cross-section 1
rigid cable 1 x / 2 x

2.5 / 2.5mm

> 2 x 106
120

Diaphragm media resistance MDR 53


1200

10 A

- 5...+ 80 C

Acetylene, Butane, Natural gas, Petroleum,


Vinegar 25 %, Glycerol, Carbon dioxide, Air,
Propane, Sulphur dioxide, Silicon oil, Water,
Distilled water, Hydrogen, Sea water

resistance

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Dimensions / Circuit Diagrams MDR 53

Pressure switch MDR-53

www.condor-cpc.com

Page 4.13

Control pressure switch MDR 53


Accessories MDR 53
Order
reference

Description

Weight
in g

Part No.

WN 5
PG 16 V-5
PG 16 Z-5
PG 16 ZK-5
PG 16/13,5 Z
PG 16/13,5 ZK
PG 16/11 V-5

Cable glands
Grommet
Cable glands, complete
With strain relief
With strain relief and cable support
Reduced to PG 13,5 with strain relief
Reduced to PG 13,5 with strain relief and cable support
Reduced to PG 11

6
12
12
12
12
12
12

201953
201960
201977
201984
202004
202011
201991

MW 5

Mounting bracket

120

230045

Cover
Cover without On/Off push-buttons

130

230052

H5
(Cover MDR 5)

Cable glands MDR 53

WN 5

PG 16 V-5

PG 16 Z-5

PG 16 ZK-5

PG 16/11 V-5

Accessories, Wall-mounting bracket / Cover MDR 53

MW 5

Page 4.14

www.condor-cpc.com

H5

Control pressure switch MDR 53


Pressure Diagrams MDR 53

www.condor-cpc.com

Page 4.15

Control pressure switch FF 142


Control pressure switch FF 142
Pressure ranges up to 40 bar
Ample wiring room
Simple calibration
2 SPDT's
Acc. to EN 60947
Rigid enclosure
Degree of Protection IP 55
Scale with bar and psi values

Applications
The FF 142 Series is a pressure switch which has
been standardized in a wide variety of industrial,
commercial and sea-going applications to monitor
or control the pressure of liquid or gaseous media:
- Pipelines
- Containers
- Pressure vessels
- Apparatus
- Process technology
- Pneumatics and hydraulics
- Refrigeration and heating plants
- Lubrication systems
- Pump motors for water supply to dwellings

Function description
Turning the setting knob Pmax. changes both the
upper and the lower switch points. By turning the
differential spindle Dp only, the lower switch point
is adjusted, while the upper setting remains
unchanged.

Construction
The standard FF 142 series are fitted in insulation
enclosures, made of ABS. Large clear scales
ease exact adjustment of upper switch point and
switching differential. They are marked both in bar
and in psi units. Scales are connected to the
frame of the device and remain in place, when the
cover is removed. Ample wiring room simplifies
wiring.

Type overview
FF 142-.. DAH
with Perbunan diaphragm, standard enclosure, suitable for oil, water, air etc.
Order
reference
FF 142-6 DAH
FF 142-8 DAH
FF 142-9 DAH

Upper switch pt.


adjustable
0.2 1.5
1 ... 8
2 ... 21

Pressure diff.
adjustable
0.12 ... 0.5
0.4 ... 2.4
0.8 ... 6

Lower switch pt.


adjustable
0.1
0.1
0.1

Max. pressure
(bar)
5
10,5
25

Standard
setting (bar)
0,8 / 1
4/5
10 / 12

Part No.
1090500004
1090500003
1090500002

Type overview
FF 142-.. AAC
Pressure switch with stainless steel bellows, standard enclosure
Suitable for ammonia and other aggressive media
Order
reference
FF 142-3 AAC
FF 142-5 AAC
FF 142-10 AAC

Page 4.16

Upper switch pt.


adjustable
-0.4 ... 8
2 ... 22
5 ... 40

Pressure diff.
adjustable
0,6 ... 3
2 ... 9
2 ... 10

www.condor-cpc.com

Lower switch pt.


adjustable
-1
0.1
0.1

max. pressure
(bar)
25
30
50

Standard
setting (bar)
2/4
12 / 16
21 / 25

Part No.
1090500001
1090500005
1090500009

Control pressure switch FF 142


Control pressure switch FFg 142
Pressure ranges up to 40 bar
Ample wiring room
Simple calibration
2 SPDT's
Acc. to EN 60947
Die-cast aluminum enclosure
Degree of protection IP 55
Scale with bar and psi values

Type overview
FFg 142-.. DAH
with Perbunan diaphragm, silumin (die-cast aluminum) enclosure, suitable for oil, water, air etc.
Order
reference
FFg 142-6 DAH
FFg 142-8 DAH
FFg 142-9 DAH

Upper switch pt.


adjustable
0.2 1.5
1 ... 8
2 ... 21

Pressure diff.
adjustable
0.12 ... 0,5
0.4 ... 2.4
0.8 ... 6

Lower switch pt.


adjustable
0.1
0.1
0.1

Max. pressure
(bar)
5
10.5
25

Standard
setting (bar)
0,8 / 1
4/5
10 / 12

Part No.
1090500025
1090500026
1090500027

Type overview
FFg 142-.. AAC
Pressure switch with stainless steel bellows, silumin enclosure
Suitable for ammonia and other aggressive media
Order
reference
FFg 142-3 AAC
FFg 142-5 AAC
FFg 142-10 AAC

Upper switch pt.


adjustable
-0.4 ... 8
2 ... 22
5 ... 40

Pressure diff.
adjustable
0.6 ... 3
2 ... 9
2 ... 10

Lower switch pt.


adjustable
-1
0.1
0.1

Max. pressure
(bar)
25
30
50

Standard
setting (bar)
2/4
12 / 16
21 / 25

Part No.
1090500028
1090500029
1090500030

Technical Data FF 142 / FFg 142


Technical Data FF 142 / FFg 142 acc. to EN 60947
16 A

Rated operational current Ie AC 1


Ue=230 V (1~)
Rated operational current Ie AC 15
Ue=230 V (1~)
Rated operational current Ie DC 13
Ue= 230 V DC

6A

Technical Data FF 142 / FFg 142 acc. to EN 60947


Rated operational current Ie AC 1
Ue=400 V (3~)
Rated operational current Ie AC 15
Ue=400 V (3~)

Ambient temperature range


With perbunan diaphragm
Contacts
Weight
Approx.

4A

0,1 A

Technical Data enclosure FF 142


Protection
Acc. to DIN 40050/IEC 529
Resistance of vibration
0 up to 1000 Hz
Ambient temperature range

10 A

Technical Data enclosure FFg 142


IP 55
4g

-50 C...+70 C
-30 C...+70 C
2 SPDT's
ca. 0,8 kg

Protection
Acc. to DIN 40050/IEC 529
Vibration resistance
0 up to 1000 Hz
Ambient temperature range
Ambient temperature range
With perbunan diaphragm
Contacts
Weight
Approx.

IP 65
4g
-50 C...+70 C
-30 C...+70 C
2 SPDT's
ca. 1.2 kg

www.condor-cpc.com

Page 4.17

Control pressure switch FF 142


Diaphragm media resistance FF 142 / FFg 142
Perbunan diaphragm
Acetylene, Gasoline, Butane, Diesel,
Natural gas, Petroleum, Ethylene glycol,
Glycerol, Fuel oil, Urine, Carbon dioxide,
Carbonic acid, Air, Mineral oils,
Vegetable oil, Propane, Silicon oil,
Nitrogen, Synthetic oils, Water, Distilled
water, Hydrogen, Sea water, Steam

resistance

Diaphragm media resistance FF 142 / FFg 142


Stainless steel bellows
Acetone, Ammonia, Acetylene, Gasoline,
Benzene, Butane, Butyl acetate, Butyl
alcohol, Diesel, Dimenthylbenzene, Natural
gas, Petroleum, Ethylene glycol, Ethyl
acetate, Glycerol, Fuel oil, Carbon dioxide,
Carbonic acid, Cooling liquid, Air, Methyl
chloride,
Mineral
oils,
Ozone,
Perchlorethylene, Vegetable oil, Phenolic
acid, Propane, Oxygen, Sulfur dioxide,
Nitrogen,
Synthetic
oils,
Toluene,
Trichlorethene, Water, Distilled water,
Hydrogen, Sea water, Steam

resistance

A detailed overview of diaphragm media resistance for all


pressure switches can be found in the table on page 2.11

Dimensions FF 142 / FFg 142

Control pressure switch FF 142

Control pressure switch FFg 142

Circuit Diagrams FF 142 / FFg 142

Pressure switch FF 142 / FFg 142

Accessories Control pressure switch FF 142 / FFg 142


Order
reference

Description

Weight
in g

Part No

1090401021

H 124-88

Blanking plugs and knobs


Plug 142

R-AD 6
R-AD 10-FN 43
H 124-114

Cable glands
Ermeto-steel connector, for 6 mm steel tube
Ermeto- steel connector, for 10 mm steel tube
Gauge steel fitting Stahl, G 3/4 - G 1/2

100
100
180

1090501019
1090401005
1090501004

H 124g-127

Mounting plate

115

1090501006

Accessories Dimensions FF 142 / FFg 142

Blanking plug 142


H 124-88

Page 4.18

Ermeto-cable gland
R-AD 6

www.condor-cpc.com

Ermeto-cable gland
R-AD 10-FN 43

Gauge fitting
H 124-114

Control pressure switch FF 142


Accessories Dimensions FF 142 / FFg 142

Mounting plate H 124g-127

Pressure Diagrams FF 142 / FFg 142

www.condor-cpc.com

Page 4.19

Control pressure switch PS 1


Control pressure switch PS 1

Pressure ranges up to 31 bar


Simple calibration
1 SPDT
Acc. to EN 60947
UL / CSA-approval
Also for vacuum applications

Features

Wiring bridge for reduced installation costs

Tight adjustable differentials (depending on

Different mounting plates

type)

Special approvals

Range and differential adjustments in bar und


psi

Range

and

differential

adjustments

are

Description
The PS 1 is an adjustable pressure switch for use in
refrigeration units and heat pumps.

individually sealable
-

Change over contacts with high ratings

Cover with captive screw

Robust, finger protected terminals with self


retaining screws cable centering

Test lever with front operation for maintenance


and plant filling

Versions with automatic manual reset

Convertible

reset

automatic

manual

Special versions
-

Alternative pressure connectors including 6mm


ODF

These pressure switches serve to fulfil many different


control purposes in the units (e.g. Pump-Down) and as
safety devices, e.g. safety pressure limiter against rising
pressure.
While control functions are usually intended for mostly
acceptable or optimized unit operations, safety
functions are generally absolutely required by national
law. Following national and international standards
therefore, facilitates the abidance of legal requirements.
Standardization is within the EC a continuous process.
The most important standards for safety and
environmental requirements for refrigeration units are
EN 378 und DIN 8901.
The PS1 series contains pressure switches which have
been built and approved according to DIN 32733.
Therefore these pressure switches can be used to fulfil
the requirements of DIN 8901and EN 378.

Golf-flashed contacts for circuits with low


contact current loads (PLC's)

Type overview PS 1

PS 1 - A1R
PS 1 A2R
PS 1 A3R
PS 1 A4R
PS 1 A5R
PS 1 A6R

Upper switch
point
(bar)
- 0.75 .. 3
- 0.8 .. 1.5
- 0.5 .. 7
1 .. 20
6 .. 31
4 .. 12

Page 4.20

www.condor-cpc.com

Order
reference

Pressure diff.
(bar)

Lower switch
point (bar)

Factory
setting (bar)

Leakage test
pressure (bar)

Pressure
connection

Part No.

0.25 .. 2
0.2 .. 1
0.5 .. 5
1 .. 10
2 .. 15
0.5 .. 7

- 0.9
- 1.0
- 0.9
0.3
3.0
0.1

0.5 / 1
0.5 / 1
3.5 / 4.5
8 / 10
16 / 20
6/7

13
13
13
23
36
16

G outer
G outer
G outer
G outer
G outer
G outer

1090600007
1090600002
1090600008
1090600004
1090600009
1090600011

Control pressure switch PS 1

Technical Data PS 1
Technical Data PS 1 acc. to EN 60947 UL/CSA
Rated operational current Ie AC 1
Ue=230 V AC
Rated operational current Ie AC 15
Ue=230 V AC
Rated operational current Ie DC 13
Ue=230 V DC

24 A /
230 V AC
10 A /
230 V AC
0.1 A / 230 V AC
3 A / 24 V AC
6 A / 12 V AC

Motor rating (FLA)

24 A /
230 V AC
144 A /
230 V A

Locked rotor (LRA) / startup (AC3)

Technical Data PS 1 acc. to EN 60947 UL/CSA


Ambient temperature
storage, transportation and operation
Temperature at pipe tap

- 50 C ... + 70 C
- 50 C ... + 70 C

Dust and water protection


EN 60529 / IEC 529

Vibration resistance

IP 44 *

4 g 10...1000 Hz
** Switch mounted flush against wall

Diaphragm media resistance PS 1


Brass
Materials PS 1
Material: Cover
Frame (yellow chromate)
Materials with medium contact:
Pressure connection (A) /
Pressure connection (K, L) / bellows

Polycarbonate(PC)
Steel

Brass/Bronze
Copper/Bronze

resistant
Acetone, Acetylene, Gasoline,
Benzene, Butane, Butyl alcohol,
Diesel, Natural gas, Ethylene glycol,
Petroleum, Carbon dioxide, Carbonic
acid, Air, Mineral oils, Vegetable oil,
Propane, Oxygen, Sulphur dioxide,
Water, Hydrogen
A detailed overview of diaphragm media resistance for all
pressure switches can be found in the table on page 2.11

Dimensions / Circuit Diagrams PS 1

Control pressure switch PS 1

Control pressure switch PS 1

www.condor-cpc.com

Page 4.21

Control pressure switch PS 1

Pressure Diagrams PS 1

Page 4.22

www.condor-cpc.com

Level Monitoring

Overview

Level measurement methods

Page
5.02

PSN

Float switches which switch On and Off


depending on the cable length

5.06

ENP

Electronic pump control


Single and dual pump control with
monitoring functions

5.10

ENR

Electronic level switch


Measuring range 0,1 2 m
Output signal 0 - 10 V

5,12

HRH - 2

Electronic level relay


For level monitoring

5.14

ENS

Stainless steel level sensor


Output signal 4 - 20 mA

5.16

www.condor-cpc.com

Page 5.01

Level control technology

For level measurement there are different methods that can be used
1. Level measurement method using
float switches

Outdoor enclosure with

CPSmodular

2. Impact pressure

2.1 Impact pressure method in closed

Lid

systems
Outlet
Tube / Cable

Stop valve

Inlet

Shaft
(Concrete / plastic)

Backlog
vane

2.2 Impact pressure method in


open systems

2.2.1 Open system method with


air replenishment

Pump(s)
Fixture and
Quick exchange

2.2.2 Open system method with


Level sensor

bubblers

3. Conductivity measurement method

4. Piezoresistive measuring method

1. Description float switches


In this application, contacts placed within a
floating enclosure are closed / opened
depending on the inclination angle of the float
switch.

Application e.g. using:


Float switches

PSN X SP
Page 5.02

www.condor-cpc.com

Level control technology

2.1 Impact pressure method, closed system

Application e.g. using:


Electronic level
transducer ENI 2
and
Closed wet bell GGL

In this application the level change is


transmitted via a pneumatic tube to the sensor
and evaluated. The two types of systems closed and open - are described in more detail
below:

Closed system
For the use of a closed system, a completely
sealed measuring system is an absolute necessity.
A leak in the system, through which air can diffuse,
leads to a drop in pressure and subsequently a
malfunction of the device. The sealed bell GGL-8
(see accessories section) placed into the medium
seals the measurement system at the "measuring
point".

2.2.1 Impact pressure method, open system with air replenishment

Application e.g. using:


Level control ENP
and
Open wet bell

OGL-GU

Open systems
In open systems, the medium to be monitored
creates pressure inside the pneumatic tube
which is then electronically evaluated. Any
leaks, which could lead to false measurement
results, can be compensated for by suitable
aeration or by bubbler operation.
Air replenishment operation
Open systems which function without aeration
must achieve a regeneration of pressure within the
system - this can be reached by an increase in
volume and temporary operation in air
replenishment mode. Any air losses in the
measurement system will thereby be compensated
for which, during the emptying process, causes the
level to drop so far at regular intervals that the bell
becomes exposed and air can therefore penetrate
into the system (air replenishment).
In addition, with the help of a wet bell, the air
volume within the measuring system should be
increased.

www.condor-cpc.com

Page 5.03

Level control technology

2.2.2 Impact pressure method, open system using bubblers

In this application, the aid of a small


compressor is necessary, whereby in either
continuous or periodic operation, air is fed into
the system. The pressure within the measuring
system (pneumatic tube) therefore remains
constant. Only when a change in the level
occurs is the pressure altered in the measuring
system, which is subsequently detected by the
evaluating unit.
Application e.g. using:
Electronic level relay ENR2
T-connector for pneumatic tube
Small air compressor Rena

Air 100

Open wet bell OGL

3. Conductivity measuring method


In this application, immersion electrodes are
connected to an electronic analyser. When the
electrodes are moistened by the liquid being
measured, their conductivity alters correspondingly. One or two variable threshold
values can then be adjusted.

Application e.g. using:


Electronic level relay HRH-2 and
Electrodes TEL

Page 5.04

www.condor-cpc.com

- ..

Level control technology

4. Piezoresistive measuring method

In this application, a level sensor is lowered


into the medium within a sealed enclosure,
whereby ceramic or piezoresistive sensors
are used. The filling level pressure then acts
directly on the ceramic or piezoresistive
sensor and the subsequent value is then
transmitted as a 4-20 mA signal via the
connecting lead.
Application e.g. using:
Electronic pump control CPS
Level sensor ENS

modular 2 and

www.condor-cpc.com

Page 5.05

Float switch PSN

Float switches which switch ON or OFF depending on the cable length


Type Designations
PSN-O
Float switches for emptying. On reaching the upper switching threshold the switching mechanism activates the pump. On
reaching the lower switching threshold the pump is switched off. This float switch can also be used as run dry protection.

PSN-F
Float switches for filling. On reaching the lower switching threshold the switching mechanism activates the pump. On
reaching the upper switching threshold the pump is switched off.

PSN-X
Float switches for filling and emptying

PSN-.. + ST
Float switch with plug and socket for pump connection.

PSN-O DB
Float switches for emptying with integrated cable breakage and short-circuit monitoring, with gold flashed contacts.

PSN-X-SP
Float switches for filling and emptying for PLC application and for intrinsically safe circuits, with gold flashed contacts.

Neoprene Insulated Lead


Highly flexible lead acc. to VDE 282 Part 4
resp. HD 22.4 S3 guarantees a long service life
Protective Conductor Connection acc. to
VDE 0631 Part 1 protection class 1 resp. EN
60730-1
A metal shield connected to the protective
conductor of the lead ensures additional
protection against electrical shock.

Perfect Casing
The inner chamber with the switch mechanism
and lead are seamlessly enclosed by isolating
polypropylene.

Contact Rating
Motors with a switching capaacity of up to 1.1
kW (at 250 V~) may be switched directly.
High Quality HR-Foam Floating Body
Physical properties and chemical resistance of
the polypropylene body are extraordinarily high,
so that damages due to mechanical impact or
chemical influence may be ruled out.

Page 5.06

www.condor-cpc.com

KLS Ball Guiding System


The new ball guiding system
KLS ensures an even higher
switching accuracy within the
tolerance range.

Float switch PSN

Type overview float switches PSN


Order reference

Float switch
PSN- ..

Float switch

Description

Cable
length
3m
5m
10 m
15 m
20 m
30 m

Weight
in g
500
650
1000
1350
1700
2400

Part No.

PSN-O 3 m
PSN-O 5 m
PSN-O 10 m
PSN-O 15 m
PSN-O 20 m
PSN-O 30 m

for emptying

234166
234173
234180
234197
234203
237082

PSN-F 3 m
PSN-F 5 m
PSN-F 10 m
PSN-F 15 m
PSN-F 20 m

for filling

3m
5m
10 m
15 m
20 m

500
650
1000
1350
1700

234210
234277
234234
234241
234258

PSN-X 3 m
PSN-X 5 m
PSN-X 10 m
PSN-X 15 m
PSN-X 20 m

for filling and emptying


export-version without
protective conductor
1 SPDT

3m
5m
10 m
15 m
20 m

500
650
1000
1350
1700

234265
234272
234289
234296
234258

PSN-O + ST 5 m
PSN-O + ST 10 m
PSN-F + ST 5 m
PSN-F + ST 10 m

Float switch with plug


and socket for
pump connection

5m
10 m
5m
10 m

750
1100
750
1100

234319
234326
234333
234340

PSN-O DB 5 m
PSN-O DB 10 m

for emptying
with integrated cable breakage
and short-circuit monitoring, with
gold flashed contacts

5m
10 m

650
1000

234457
234364

PSN-X SP 5 m
PSN-X SP 10 m
PSN-X SP 15 m
PSN-X SP 20 m
PSN-X SP 30 m
PSN-X SP 40 m

for filling and emptying


for PLC application and for
intrinsically safe circuits, with
gold flashed contacts, exportversion without protective
conductor, 1 SPDT

5m
10 m
15 m
20 m
30 m
40 m

650
1000
1350
1700
2400
3100

234371
234388
236092
236115
245254
245261

Weight
in g
400

Part No.

PSN- ..+ ST

Weight BG - PS

Accessories for Float switches PSN

Cable support K - PS

Order reference

Description

BG - PS

Weight for float switch, color of body blue


(for free setting of the switching differences)

IG - PS

Weight for float switch, color of body yellow


(for free setting of the switching differences)

180

234401

K - PS

Cable support for float switch PSN, (fixing


by means of a standard clip)

234418

www.condor-cpc.com

236658

Page 5.07

Float switch PSN

Technical data float switches PSN


Technical Data PSN-O/F/X
Rated operational voltage
Ue
Rated operational current
Ie
Contact rating

Technical Data PSN-O DB

250 V ~
400 V ~
10 (8) A
10 (4) A
1.1 kW (1.5 PS)

Max. cycles
Cycles 50 E3
Temperature resistance
Cable VDE 282 Part 4 12/95
Body
Protection
watertight, depth 10 m
Wire cross sections
VDE 0631 Part 1 01/96
Lead
black

50.000

60 C
85 C
IP 68
3 x 1 mm
H 07 RN-F

Rated operational voltage


Ue
Rated operational current
Ie
Max. cycles
Cycles 50 E3
Temperature resistance
Cable VDE 282 Part 4 12/95
Body
Protection
watertight, depth 10 m
Wire cross sections
VDE 0631 Part 1 01/96
Lead
black

< 30 V-AC
11 mA (R=2,7k)
2.4 mA (R=12,7k)
50.000

60 C
85 C
IP 68
3 x 1 mm
H 07 RN-F

Resistance Body / Cable


Resistance

Limited resistance

Formic acid (hydrous 10%), Gasoline (normal), Diesel,


Formaldehyde (hydrous 40%), Glycerine, Fuel oil, Lactic
acid (hydrous 10%), Phosphoric acid (hydrous 10%), Nitric
acid (hydrous 10%), Sulfuric acid (hydrous 35%), Washing
powder

Acetic acid (hydrous 10%), Nitric acid (hydrous 10%),


Chlorinated water, Hydrogen peroxide

Types

PSN-O (Float switch for emptying)

PSN-F (Float switch for filling)

Contact closes in upper position and switches the pump on.

Contact opens in upper position and switches the pump off.

PSN-X (Float switch for filling and emptying)


Export-version with 1 SPDT without protective conductor and VDE-Approval mark.

Page 5.08

www.condor-cpc.com

Float switch PSN

Circuit Diagrams Float switch PSN

Float switch PSN-O

Float switch PSN-F

Float switch PSN-X

Float switch PSN-X

for emptying

for filling

here in function for emptying

here in function for filling

Switching Diagram PSN

Inner wiring PSN-O DB

10,0 k
R2
2,7 k
R1
Lead length L in cm
Four switching conditions can be measured:

Upper and lower


switching
point
depending on lead
length

R=0
R = 2.7 k
R = 12.7 k
R=

Short-circuit
Float switch closed
Float switch open
Cable breakage

The conditions can be evaluated with any PLC or with


special controls featuring an analogue input.

Dimensions

Float switch PSN

Weight BG-PS / IG-PS

Cable support K-PS

www.condor-cpc.com

Page 5.09

Electronic pump control ENP

Electronic pump control ENP


Electronic single/dual pump control with monitoring features

Electronic pump control for filling and emptying a tank with integrated relative pressure
transducer for panel board mounting, connection for pneumatic tube, four adjustable
switching points, 3 relay outputs, staging and sequencing control, isolating transformer acc.
to VDE 0550.
Function: The device analyses the pressure applied to the sensor. Two pumps for emptying
a tank are connected to terminals 11/14 and 21/24 an alarm can be connected to terminals
31/34.
All levels are adjustable. The LED's illuminate when the pumps, or the alarm are switched
on. The relays are activated. The tripping delay for the alarm is fixed, preset value.

Type overview ENP


Order
reference

Measuring
range (m)

ENP 2.3

0.12 m

ENP 4.3

0.14 m

ENP 10.3

0.1 10 m

Setting
range (m)

As Measuring
range

Max.
inaccuracy
at 25C

Output signal
(V DC)

Resolution

Operating
voltage
UB (V-DC)

Max. perm.
level (m)

Part No.

2.5 %

0.01 m

0 10 V

230

10 m

3700400

2.5 %

0.01 m

0 10 V

230

10 m

3700405

2.5 %

0.10 m

0 10 V

230

20 m

3700410

Other operating voltages on request

Accessories ENP
Order
reference
KL-S

Description

Part No.

Jack 2.5 mm for analogue output connection (cable length 5 m)

3709400

Technical Data ENP


Technical operating data

Enclosure

Permissible operating voltage range

10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0,1 %

Clearance and creepage distances

100 %
-20C up to
+60C
10 % up to 90
%
-40C up to
80C
VDE 0110

Working position

any position

Power consumption

max. 1.5 VA

Material

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Enclosure-protection
Protection against shock
Terminals

IP 40
acc. VBG 4
Cage clamps

Cross section

2.5 mm

Weight

135 g

Male jack plug


Jack 2,5 mm

2.5 mm

Power section
Pressure connection
Quick connect
suitable pneumatic tube e.g.

6 x 1 mm
Festo PAN

Analogue output
Analogue voltage signal
max. 5 mA short-circuit proof

Page 5.10

www.condor-cpc.com

0 - 10 V

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
per contact
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles

250 V-AC
6 A-AC
1.500 VA (AC)
50 W (DC)
7
approx. 1 x 10
approx. 2 x 10

Electronic pump control ENP


Dimensions ENP

Wiring diagrams ENP

Terminal connection

Terminal connection

Analogue
output

Analogue
output

0 10 V

0 10 V
B

A1 A2 = Operating voltage UB
B
= Quick-connect for pneumatic tube
11, 12, 14 = SPDT contacts Pump 1
31, 34
= Alarm contact
+, = Analogue output 0 10 V
Bridge between contacts 11 - 21
Bridge between contacts 14 - 24

ENP as single pump control

A1 A2 = Operating voltage UB
B
= Quick-connect for pneumatic tube
11, 12, 14 = SPDT contacts Pump 1
21, 24
= Contacts Pump 2
31, 34
= Alarm contact
+, = Analogue output 0 10 V

ENP as dual pump control

www.condor-cpc.com

Page 5.11

Electronic level switch ENR


Electronic level switch ENR
Electronic level switch for all ranges from 0.1 2 m
For panel board mounting
Measurement according to impact pressure method
Relay output
Output signal: 0 10 V
Electronic level switch with integrated relative pressure transformer for panel board
mounting, quick-connect for pneumatic tube, two adjustable thresholds, relay output and
isolating transformer according to VDE 0550.
Function: The device evaluates the pressure applied to the sensor. Should a pump for
emptying a tank be connected to terminals 11 and 12, then the pump is switched on when
the upper threshold is exceeded. The pump is switched off when falling below the lower
threshold. Both thresholds are adjustable. The LED illuminates when the pump is running,
whereby the relay is deactivated.

Type overview ENR


Order
reference

Measuring
range (m)

Setting
range (m)

Resolution

Max. perm.
level (m)

Max.
inaccuracy
at 25C

Operating
voltage
UB (V-DC)

Output signal
(V DC)

Part No.

0.12 m

gleich

0.01 m

10 m

2.5 %

230

0 - 10

3700300

ENR 2

Accessories: open and closed wet bell

Accessories ENR
Order
reference
KL-S

Description

Part No.

Jack 2.5 mm for analogue output connection (cable length 5 m)

3709400

Technical Data ENR


Technical operating data

Enclosure

Permissible operating voltage range

10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient and
media temperature
Permissible ambient humidity
rel. humidity, non-condensing
Permissible storage temperature

< 0,1 %

Clearance and creepage distances


Working position

100 %
-20C up to
+60C
10 % up to 90
%
-40C up to
80C
VDE 0110
any position

Power consumption

Material

RABS flameproof, ULapproved


snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Enclosure protection
Protection against shock
Terminals

IP 40
acc. VBG 4
Cage clamps

Cross section

2.5 mm

Weight

135 g

Male jack plug


Jack 2.5 mm

2.5 mm

max. 1 VA

Power section
Pressure connection
Quick connect
suitable pneumatic tube e.g.

6 x 1 mm
Festo PAN

Analogue output
Analogue voltage signal
max. 5 mA short-circuit proof

Page 5.12

www.condor-cpc.com

0 - 10 V

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
per contact
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles

250 V-AC
6 A-AC
1.500 VA (AC)
50 W (DC)
7
approx. 1 x 10
approx. 2 x 10

Electronic level switch ENR

Dimensions ENR

Wiring Diagram ENR

www.condor-cpc.com

Page 5.13

Electronic level relay HRH-2

Electronic level relay HRH-2


Level relay for level monitoring,
using 2 or 3 electrodes
1 SPDT
Standard relay for level monitoring with 1 and 2 threshold values, infinitely variable limit
values, 1 SPDT and isolating transformer according to VDE 0550.
Function: The electrodes are connected to the relay. Should the tank be made of a
conductive material, it can be used as a third electrode (For connection see wiring diagram).
AC current is used in order to avoid polarisation, electrolysis and undesired oxidation of the
electrodes.
To minimize false relay switching (e.g. pollution of the probes, humidity .), the switching
sensitivity can be adjusted to the conductibility of the respective media.

Type overview HRH-2


Ordering reference

adjustable
hysteresis (k)

Time reaction

Adjustable
delay time(ms)

Operating
voltage (V-AC)

Part No.

5 - 100

< 400 ms

1 10 sec.

230 V-AC

3702500

HRH-2 230

Accessories, electrodes for HRH-2


Type

Description

Application

Part No.

TEL-00

Single electrode

236467

TEL-05

Single electrode with 5 m cable H07 RN-F 1 x 1,5 mm

3702100

TEL-10

Single electrode with 10 m cable H07 RN-F 1 x 1,5 mm

3702110

TEL-20

Single electrode with 20 m cable H07 RN-F 1 x 1,5 mm

3702120

TEL-TW-05

Single electrode with 5 m cable TML-B 1 x 1,5 mm


Waquasan Reg. Nr. 11156/09564

TEL-TW-10

Single electrode with 10 m cable TML-B 1 x 1,5 mm


Waquasan Reg. Nr. 11156/09564

TEL-TW-20

Single electrode with 20 m cable TML-B 1 x 1,5 mm


Waquasan Reg. Nr. 11156/09564

3702200
Suitable for use with
potable water.
Temperature range
0 90C

3702210
3702220

Technical data HRH-2


Technical operating data

Technical operating data

Permissible operating voltage range

-15 % +10 %

Operating voltage influence


at 10% operating voltage fluctuation
Duty factor
ED
Permissible ambient temperature

< 0.1 %

Page 5.14

100 %
-20C up to +55 C

www.condor-cpc.com

Permissible storing temperature


Clearance and creepage distances

-30C up to +70 C
VDE 0110

Working position

any position

Power consumption

max. 2,5 VA

Electronic level relay HRH-2


Technical Data HRH-2
Enclosure
Material

Output contacts
RABS flameproof, ULapproved

snap on 35 mm DIN-rail
connector acc. to EN 50 035

Mounting
Degree of Protection

IP 40

Shock protection

acc. to VBG 4

Connection

Box-type terminals

Max. cross-section
with cable end sleeves

Series voltage
acc. to VDE 0660 and VDE 0110 Group C
Maximum continuous current
per contact
Maximum switching capacity
per contact
Mechanical life
Cycles
Electrical life (max load)
Cycles

250 V-AC
6 A-AC
4.000 VA (AC)
384 W (DC)
7
approx. 3 x 10
approx. 0,7 x 10

2.5 mm
1.5 mm

Wiring Diagram HRH-2

Dimensions HRH-2 / TEL-05

Electronic level relay HRH-2

Electrode TEL-05

www.condor-cpc.com

Page 5.15

Stainless steel level sensor ENS

Stainless steel level sensor ENS

With ceramic measuring cell, shielded cable and a specially designed stainless steel enclosure, Condor
offers a precision level sensor for all different types of applications, like e.g. wastewater. The sensor
offers extremely high media resistance and the especially large membrane makes the sensor insensitive
to pollution. The shielded cable protects the output signal (4 20 mA) against electromechanical
influences. The ENS level sensor is also available with ATEX (explosive atmosphere) approval.

Type overview ENS


Order reference
ENS 1/10
ENS 4/10
ENS 10/15

Measuring range
up to 1.0 m
up to 4.0 m
up to 10.0 m

Cable length
10 m
10 m
15 m

EX Approval

Weight in g
1000 g
1000 g
1250 g

Part No.
245414
290193
290049

ENS 1/10 EX
ENS 1/15 EX
ENS 1/20 EX
ENS 1/25 EX
ENS 1/30 EX

up to 1.0 m
up to 1.0 m
up to 1.0 m
up to 1.0 m
up to 1.0 m

10 m
15 m
20 m
25 m
30 m

X
X
X
X
X

1000 g
1250 g
1500 g
1750 g
2000 g

245421
245438
290025
245445
245452

ENS 4/10 EX
ENS 4/15 EX
ENS 4/20 EX
ENS 4/25 EX
ENS 4/30 EX
ENS 4/40 EX

up to 4.0 m
up to 4.0 m
up to 4.0 m
up to 4.0 m
up to 4.0 m
up to 4.0 m

10 m
15 m
20 m
25 m
30 m
40 m

X
X
X
X
X
X

1000 g
1250 g
1500 g
1750 g
2000 g
2500 g

242673
242680
290209
290216
290230
290247

ENS 10/10 EX
ENS 10/15 EX

up to 10.0 m
up to 10.0 m

10 m
15 m

X
X

1000 g
1250 g

242703
242697

Accessories ENS
Description

Part No.
290223
242227
242735
242734

Galvanized fixing clamp for level sensor


Stainless steel fixing clamp for level sensor
Protective cap for level sensor as replacement
Cable extension, max. 200 m possible

Technical data ENS


Technical operating data
Measuring range:
Output signal:
Accuracy:
Adjustment time:
Auxiliary voltage:

Temperature range:

Page 5.16

0 25 mbar up to
0 60 bar
4 20 mA,
2-wire
< 0.2 %
200 ms (other values on
demand)
9...32 V DC, max. 30
mA(12...30 V for EXtype)
-25...80 C (-25..120 C)
(-25...70 C for EX-Type)

www.condor-cpc.com

Technical operating data


Temperature influence:
Housing

< 0,015 %/K


of measuring range
Stainless steel, 1.4571

Degree of Protection:

IP 68

Electrical connection:

Kevlar braided PE cable,


wire cross-section 0,34
mm, with pressure
compensation

EX-protection:

EEx ia IIC T6

Stainless steel level sensor ENS


Wiring diagram ENS

Level Sensor ENS

Dimensions ENS

Level Sensor ENS

Application example:
Level sensor ENS
Monitors e.g. Wastewater/Water
level in a pump shaft

www.condor-cpc.com

Page 5.17

Page 5.18

www.condor-cpc.com

Motor Technology

Overview

Page
6.02

OKE2

Manual motor starters with push-button


3-pole operation
Thermal trip
Setting range 1.0 25.0 A; 500 V AC
Switching capacity 11 kW
Switching operations 60/h

MKE2

Manual motor starters with push-button


3-pole operation
Thermal/magnetic trip
Setting range 1.0 25.0 A; 500 V AC
Switching capacity 11 kW
Switching operations 60/h

6.02

TFE2

Manual motor starters with push-button


3-polig
Thermal/magnetic trip
Thermal contacat
Setting range 0.40 10.0 A; 230 V AC

6.08

TFA2

Manual motor starters with push-button


3-pole operation
Electronic release
Thermal contact
Setting range 0.10 25.0 A; 400 V AC

6.08

OKN

Manual motor starters with push-button


3-pole operation
Thermal trip with phase drop protection
Setting range 0.25 27.0 A; 500 V AC
Switching capacity 7.5 kW
Switching operations 30/h

6.10

C-SDU

Star/Delta starter
With manual motor starter
Thermal/magnetic trip
Switching capacity 5,5 / 7,5 and 11 kW

6.13

www.condor-cpc.com

Page 6.01

Manual Motor Starters OKE2 / MKE2

Manual Motor Starter OKE2, 3-pole


Thermal trip
Setting range 1.0 25.0 A; 500 V AC
Switching capacity 11 kW
Switching operations 60/h
Including PE/N bar (left side)

Type overview OKE2


Order reference

OKE2 1.6
OKE2 2.5
OKE2 4.0
OKE2 6.3
OKE2 10.0
OKE2 16.0
OKE2 25.0

Description
Rated current setting range
(A)
1.00 1.60 A
1.60 2.50 A
2.50 4.00 A
4.00 6.30 A
6.00 10.00 A
10.00 16.00 A
16.00 25.00 A

Packing
(units)

Weight
in g

Part No.

1
1
1
1
1
1
1

280
280
280
280
280
280
280

202 721
202 738
202 745
202 752
202 769
202 776
202 783

Manual Motor Starter MKE2, 3-pole


Thermal/magnetic trip
Setting range 0.10 25.0 A; 500 V AC
Switching capacity 11 kW
Switching operations 60/h
Including PE/N bar (left side)

Type overview MKE2


Order reference

MKE2 0.16
MKE2 0.5
MKE2 0.40
MKE2 0.63
MKE2 1.00
MKE2 1.60
MKE2 2.50
MKE2 4.00
MKE2 6.30
MKE2 10.0
MKE2 16.0
MKE2 25.0

Page 6.02

Description
Rated current setting range
(A)
0.10 0.16 A
0.16 0.25 A
0.25 0.40 A
0.40 0.63 A
0.63 1.0 A
1.0 1.6 A
1.6 2.5 A
2.5 4.0 A
4.0 6.3 A
6.0 10.0 A
10.0 16.0 A
16.0 25.0 A

www.condor-cpc.com

Packing
(units)

Weight
in g

Part No.

1
1
1
1
1
1
1
1
1
1
1
1

300
300
300
300
300
300
300
300
300
300
300
300

202 158
202 165
202 172
202 189
202 196
202 202
202 219
202 226
202 233
202 240
202 257
202 264

Manual Motor Starters OKE2 / MKE2

Technical Data OKE2 / MKE2


Technical Data (OKE2 / MKE2)
Rated insulation voltage Ui
500 V AC
acc. to IEC 947-4-2 / VDE 0110
Permissible ambient temperature
Storage temperature
-25...+ 70 C
open
-25...+ 60 C
enclosed type
-25...+ 40 C
Temperature compensation
no
Climatic resistance

IEC 68 T2-3, 2-30

Glow wire resistance


acc. to IEC 695-2-1
Working position
any position
Permissible altitude

Intensity
850C
preferably
vertical
3000 m

Permissible vibration resistance


IEC 68-2-6
Permissible impact direction sine
impact (critical direction IEC 68-2-27)
Surface mounting screws
DIN-rail
Mechanical life
in cycles
Maximum switching operations
Cycles/hour

25 Hz b.+/- 1 mm
Amplitude (2,5 g)
5 g (11 ms)
2 x M4**
integrated
100.000
60

Technical Data (OKE2 / MKE2)


Main current paths
3
Number
Rated operational voltage Ue up to
16 A 550 V AC
25 A 500 V AC
Rated operational current Ie
25 A
Permissible frequency
only for magnetic short-circuit release
Current setting ranges Ie
Acc. to VDE 0660 Part 102 A, IEC 947-4-1
Numbers of ranges

40...60 Hz
125 / 0.1-25
7 / 12

Current dissipation loss


Main current paths at Ie max./Phase
Tripping curves

1.9...3.7 W
2.6...4.2 W
10A

Electro-magnetic trip

8 - 13 x In

Auxiliary contact (OKE2 / MKE2)


Auxiliary current paths
Rated insulation voltage IEC 947
Thermal current
Ith2
Short-circuit protection back-up fuse gL
MCB B 6 A

230 V
6A
10 A
B6A

**not included in the scope of delivery


Conductor cross-section (OKE 2/MKE 2)
Manual motor starters rigid cable 1 x
1 ... 6.0 mm
rigid cable 2 x
1 ... 4.0 mm
flexible cable*1 x
1 ... 6.0 mm
flexible cable* 2 x
1 ... 2.5 mm

Max. switching capacity (OKE 2/MKE 2)


Auxiliary contact Ie
24 V AC
at AC 15 up to
230 V AC

rigid cable 1 x
rigid cable 2 x
flexible cable*1 x
flexible cable* 2 x

1 ... 2.5 mm
1 ... 2.5 mm
1 ... 2.5 mm
1 ... 2.5 mm

Undervoltage/
shunt release

rigid cable 1 x
rigid cable 2 x
flexible cable*1 x
flexible cable* 2 x

1 ... 2.5 mm
1 ... 2.5 mm
1 ... 2.5 mm
1 ... 2.5 mm

may be used for low voltage and


PLC inputs acc. to DIN 19240

Enclosure/
PE/N terminal

rigid cable 1 x
rigid cable 2 x
flexible cable*1 x
flexible cable* 2 x

1 ... 4.0 mm
1 ... 4.0 mm
1 ... 2.5 mm
1 ... 2.5 mm

Standards (OKE 2/MKE 2)


The
devices
comply
with
the
requirements of major international,
European and national specifications

Auxiliary contact

Degree of Protection acc. to DIN 40050


open type enclosed type

6A
4A

400 V AC

3A

500 V AC

1A

IP 20
IP 55...65

VDE, IEC, BS,


CEI, NBN,
NEN SEV,
UTE, D, N, S

* with cable end sleeve

Undervoltage release (OKE 2/MKE 2)


Energizing voltage
% von Uc
De-energizing voltage
% von Uc
Relative Duty factor
% von Uc
Power consumption
Closing
Holding

85
35 .. 70
100

Shunt release (OKE 2/MKE 2)


Energizing voltage
% von Uc
Power consumption
Closing
Holding

ca. 70

6.0 VA
3.0 VA

6.0 VA
3.0 VA

www.condor-cpc.com

Page 6.03

Manual Motor Starters OKE2 / MKE2

Technical Data OKE2 / MKE2


Short circuit switching capacity (OKE 2/MKE 2)
40 ... 60 Hz
P1 / Icn
acc. to VDE 0660 / IEC 155-1
Taking the mains back-up fuse into
consideration
230 V
400 V
440 V
500 V

Correction factor (OKE 2/MKE 2)


Ambient temperature
Correction factor
-

5 C

1.12

+ 20 C

1.00

+ 40 C

0.89

6 kA
3 kA
3 kA
1 kA

Setting ranges, intrinsic safety and max. back-up fuse OKE2


Order
reference

Setting ranges A

Max. back-up fuse gl (A)

1.0 1.6
1.6 2.5
2.5 4.0
4.0 6.3
6.3 10.0
10.0 16.0
16.0 25.0

440 / 500 V
16
25
35
50
63
63
50

OKE2 1.6
OKE2 2.5
OKE2 4.0
OKE2 6.3
OKE2 10.0
OKE2 16.0
OKE2 25.0

Setting ranges, intrinsic safety and max. back-up fuse MKE2


Order
reference
MKE2 0.16
MKE2 0.25
MKE2 0.40
MKE2 0.63
MKE2 1.0
MKE2 1.6
MKE2 2.5
MKE2 4.0
MKE2 6.3
MKE2 10.0
MKE2 16.0
MKE2 25.0

Setting ranges A

Actuating current of the


magn. short-circuit release
(A)
1.3
2.0
3.5
5
8
13
20
32
50
80
128
200

0.10 0.16
0.16 0.25
0.25 0.40
0.40 0.63
0.63 1.0
1.0 1.6
1.6 2.5
2.5 4.0
4.0 6.3
6.3 10.0
10.0 16.0
16.0 25.0

max. back-up fuse gl (A)


230 V

400 V

500 V

No back-up fuse
required

35
50
63
63
63

63
63
63
63

25
50
50
50
50

Permissible wire protection


Order reference
4

MKE2
In (A)
0.16 bis 6.3
10
16
25

X
X
X
X

Min. protected cross-section


at 400 / 500 V AC, Cu mm
2,5
1,5
1,0
X
X
X
X

X
X
X

X
X

0,75
X

Protection of PVC-insulated cables against thermal overload due to short-circuit:


According to VDE 0100 Parts 430 and 523, cables and wires have to be protected against overload and short-circuit.
The table shows which cable cross-sections are protected against short circuit by the MKE 2.

Page 6.04

www.condor-cpc.com

Manual Motor Starters OKE2 / MKE2

Accessories OKE2 / MKE2


Order reference

Description

Packing
(units)

Weight
in g

Part No.

Hi 10
Hi 01
Hi 11

Auxiliary contacts *
Auxiliary contact 1 N.O., right
Auxiliary contact 1 N.C., right
Auxiliary contact 1 N.O./1 N.C.

1
1
1

7.5
7.5
7.5

202 288
202 301
202 325

AS 230-50
AS 400-50

Shunt release *
Shunt release 230 V / 50 Hz
Shunt release 400 V / 50 Hz

1
1

60
60

202 479
202 486

US 110-50
US 230-50
US 400-50

Undervoltage release *
Undervoltage release 110 V / 50 Hz
Undervoltage release 230 V / 50 Hz
Undervoltage release 400 V / 50 Hz

1
1
1

60
60
60

203 370
203 387
202 400

A IP 55
B IP 55
C IP 54
G IP 65
E IP 54

Enclosure/Special accessories
Enclosure, protection IP 55, up to 16 A
Enclosure with large terminal box, protection IP 55
Enclosure, protection IP 54, 5-pole, CEE-plug 16 A
Die-cast aluminum enclosure, protection IP 65
Front plate, protection IP 54

1
1
1
1
1

125
450
375
800
125

202 554
202 561
202 585
202 578
202 622

1
1
1

55
40
25

202 653
202 660
216 742

NAK
V
AZ

Enclosure-accessories
Emergency-OFF-device IP 55
Padlock blockade device IP 55
Supplementary set for enclosure, protection IP 41 to IP 55

*Auxiliary contacts, shunt and undervoltage releases must be factory installed.

Manual motor starter


MKE2 + AS

Manual motor starter


MKE2 + US

Enclosure A

Enclosure A +
Emergency-OFF-device
NAK

Enclosure B + Padlock
blockade device V

Enclosure G + MKE2

www.condor-cpc.com

Page 6.05

Manual Motor Starters OKE2 / MKE2

Dimensions OKE2 / MKE2

OKE2 / MKE2

Undervoltage release US
Shunt release AS

Enclosure A

Enclosure B

Enclosure C

Enclosure G

Front plate, protection E

Mounting template for Front plate E

Manual motor starter

Page 6.06

www.condor-cpc.com

Manual Motor Starters OKE2 / MKE2

Circuit Diagrams OKE2 / MKE2

Manual motor starter


OKE2

Manual motor starter


MKE2

Manual motor starter


MKE2
with Undervoltage release

Auxiliary contact Hi 10
( 1 N.O. )

Auxiliary contact Hi 01
( 1 N.C. )

Auxiliary contact Hi 11
( 1 N.O. / 1 N.C. )

Tripping curves OKE2 / MKE2

www.condor-cpc.com

Page 6.07

Manual Motor Starters TFE2 / TFA2

Motor starter for motors with integrated thermal contacts


TFE
Thermal/magnetic trip
Thermal contact
Single phase version 230 V (1~)
Setting range 0.4 10.0 A; 230 V AC

Type overview and Accessories TFE2


Order reference

TFE2 230
Hi 10
Hi 01
Hi 11
A IP 55

Description
Rated operational current
setting range (A)
Standard unit 0.40 10.0 A
Auxiliary contact 1 N.O.
Auxiliary contact 1 N.C.
Auxiliary contact 1 N.O./ 1 N.C.
Enclosure, Protection IP 55

Packing
(units)

Weight
in g

Part No.

1
1
1
1
1

280
7.5
7.5
7.5
125

210 078
202 228
202 301
202 325
202 554

Motor starter for motors with integrated thermal contacts


TFA
Electronic trip
Thermal contact
3-phase version 400 V (3~)
Setting range 0.10 25.0 A; 400 V AC

Type overview and Accessories TFA2


Order reference

TFA2 400
Hi 10
Hi 01
A IP 55

Page 6.08

Description
Rated operational current
setting range (A)
Standard unit 0.10 25.0 A
Auxiliary contact 1 N.O.
Auxiliary contact 1 N.C.
Enclosure, Protection IP 55

www.condor-cpc.com

Packing
(units)

Weight
in g

Part No.

1
1
1
1

340
7.5
7.5
125

210 061
202 228
202 301
202 554

Manual Motor Starters TFE2 / TFA2

Dimensions / Circuit Diagrams TFE2 / TFA2

Manual motor starter


TFE2 / TFA2

Enclosure A

Undervoltage release US
(TFA2)

Manual motor starter TFA2

Manual motor starter TFE2


optional 1N.O. and/or 1N.C.

Auxiliary contact Hi 10
( 1 N.O. )

Auxiliary contact Hi 01
( 1 N.C.)

Auxiliary contact Hi 11
( 1 N.O. / N.C. )

TFA2 +
Enclosure A

Enclosure A

www.condor-cpc.com

Page 6.09

Manual Motor Starters OKN

Manual motor starter with rotary knob, 2/3-pole


Thermal trip with phase-drop protection
Setting range 0.25 27.0 A; 500 V AC
Switching capacity 7.5 kW
Switching operations 30/h

Type overview OKN


Order reference

OKN 0.4
OKN 0.63
OKN 1.0
OKN 1.6
OKN 2.5
OKN 4.0
OKN 6.3
OKN 10.0
OKN 16.0
OKN 22.0
OKN 27.0
OKN 30.0
OKN 37.0

Description
Rated current setting range (A)

Packing
(units)

Weight
in g

Part No.

0.25 0.40 A
0.40 0.63 A
0.63 1.00 A
1.00 1.60 A
1.60 2.50 A
2.50 4.00 A
4.00 6.30 A
6.00 10.0 A
10.0 16.0 A
16.0 22.0 A
22.0 27.0 A
22.0 30.0 A (2-pole)
28.0 37.0 A (2-pole)

1
1
1
1
1
1
1
1
1
1
1
1
1

170
170
170
170
170
170
170
170
170
170
170
170
170

203 391
203 407
203 414
203 421
203 438
203 445
203 452
203 469
203 476
203 483
203 490
203 506
236 665

Technical Data OKN


Technical Data (OKN)
Rated insulation voltage Ui
acc. to IEC 947-4-7 / VDE 0110
Permissible ambient temperature
Storage temperature
open
enclosed type
Temperature compensation
Climatic resistance

500 V AC

-25...+ 70 C
-25...+ 60 C
-25...+ 40 C
yes
IEC 68 T2-3, 2-30

Glow wire resistance


acc. to IEC 695-2-1
Working position
any position
Permissible altitude
Permissible vibration resistance
IEC 68-2-6
Permissible impact direction sine
impact (critical direction IEC 68-2-27)

Intensity
850C
preferably
vertical
3000 m
25 Hz b.+/- 1 mm
Amplitude (2,5 g)
20 g (11 ms)

Technical Data (OKN)


Surface mounting
Screw mounting
Mechanical life
in cycles
Maximum switching operations
Cycles/hour
Main current paths
Number
Rated operational voltage Ue up to
Thermal current Ith
Rated operational current Ie
Current setting ranges Ie
acc. to VDE 0660 Teil 102 A, IEC 947-4-1

Numbers of ranges
Current dissipation loss
Main current paths at Ie max./Phase
Trip class
*not included

Page 6.10

www.condor-cpc.com

2 x M4*
100.000
30
2/3
37 A / 250 V
27 A / 500 V
37 A, 2-pol /
27 A, / 3-pol
22 37 A , 2-pol
0.25 27 A, 3-pol
2 / 11
1.8...3.2 W
10A

Manual Motor Starters OKN

Technical Data OKN


Conductor cross-section (OKN)
Manual motor starter
rigid cable 1 x
rigid cable 2 x
flexible cable*1 x
flexible cable* 2 x
Enclosure/
rigid cable 1 x
PE/N terminal
rigid cable 2 x
flexible cable*1 x
flexible cable* 2 x

1 ... 6.0 mm
1 ... 4.0 mm
1 ... 4.0 mm
1 ... 2.5 mm
1 ... 6.0 mm
1 ... 4.0 mm
1 ... 4.0 mm
1 ... 2.5 mm

Degr. of protection acc. to DIN 40050


open type / enclosed type
*with cable end sleeve

Switching capacity (OKN)


40 ... 60 Hz
P1 / Icn
acc. to VDE 0660 / IEC 155-1
allowing for the mains back-up fuse
230 V
400 V
440 V
500 V

6 kA
3 kA
3 kA
1 kA

IP 20
IP 54

Standards (OKN)
The
devices
comply
with
the
requirements of major international,
European and national specifications

VDE, IEC, BS,


CEI, NBN, NEN
SEV, UTE, D, N,
S, Fi

230 V

Contact rating at AC 3 (2 pole/3 pole)


-

7.5 kW

400 V

11.5 kW

500 V

15 kW

Setting ranges, intrinsic safety and max. back-up fuses


Order
reference
OKN 0.4
OKN 0.63
OKN 1.0
OKN 1.6
OKN 2.5
OKN 4.0
OKN 6.3
OKN 10.0
OKN 16.0
OKN 22.0
OKN 27.0
OKN 30.0
OKN 37.0

Setting range A
0.25 0.40 A
0.40 0.63 A
0.63 1.00 A
1.00 1.60 A
1.60 2.50 A
2.50 4.00 A
4.00 6.30 A
6.30 10.0 A
10.0 16.0 A
16.0 22.0 A
22.0 27.0 A
22.0 30.0 A
28.0 37.0 A

max. back-up fuse gL (A)


1 x 250 V
3 x 230 V, 3 x 500 V
2
6
10
16
25
35
63
63
63
35
35
50
50
-

Accessories OKN
Order reference

Description
Enclosure-accessories
Enclosure H, protection IP 41

Packing
(units)

Weight
in g

Part No

225

203 513

OKN +
Enclosure H

Enclosure H

www.condor-cpc.com

Page 6.11

Manual Motor Starters OKN


Dimensions OKN

Manual motor starter


OKN

Circuit Diagrams OKN

Manual motor starter


OKN

Tripping curves OKN

Page 6.12

www.condor-cpc.com

Enclosure H

Star/Delta starter
Star/Delta starters for motors

The Condor Pressure Control GmbH


C-SDU Star/Delta starters offer, in due
consideration of the relevant standards, the
possibility of economically operating motors
with a switching capacity greater than 4 kW
using public mains networks.
With this 2-stage starter the inrush current
(Star circuit) is reduced by 1/3 of that to be
expected when starting the motor directly.
The torque is equally reduced during startup phase.
During the start-up phase (1 32 seconds),
a special change-over relay with a contact
switching time of 40 ms, guarantees
reliable change over from star to delta
operation.
During continuous operation, all motors
connected to the Star/Delta starter are
protected by a manual motor starter with
thermal and magnetic trip.

Type overview C-SDU


Order
Reference
C-SDU 5.5

Description
5.5 kW / 400 V
Contactor coil 230 V
Manual motor starter
11 16 A (Rated current)

Packing
(units)
1

Weight
in g
4100

Part No.
238 560

C-SDU 7.5

7.5 kW / 400 V
Contactor coil 230 V
Manual motor starter
14 20 A (Rated current)

4250

238 577

C-SDU 11.0

11.0 kW / 400 V
Contactor coil 230 V
Manual motor starter
19 25 A (Rated current)

4400

238 584

www.condor-cpc.com

Page 6.13

Page 6.14

www.condor-cpc.com

Condor Pressure Control GmbH

Overview
Your Partners

Page
7.02

Our Team introduces itself

Head office and Subsidiaries

7.03

Representatives Europe

7.04

Representatives Worldwide

7.06

Terms of Delivery

7.07

www.condor-cpc.com

Page 7.01

Your Partners

Solving your problems is our priority


Our competent team will assist you in looking for a
solution to your problem as well as advise you
with regard to prices, product availability, and
delivery times, do not hesitate to contact us! Any
project you may have in mind will also find a
complete and satisfactory solution based on your
requirements.

We also offer you our services as a recognized


provider and supplier of electronic controls and
monitoring units. Furthermore, customized
electronic controls form a major part of our service
program.

We look forward to hearing from you!


Sales Germany
Stefan Kster
Product Manager
Sales Engineer
Udo Ehlen
Product Manager
Sales
Birgit Winkler
Sales Administration
Annika Wiedemann
Sales Administration

Phone:
Telefax:
Mobile:
http://
e-Mail:

+49 (0) 25 87 / 89 - 207


+49 (0) 25 87 / 89 - 44 - 207
+49 (0) 172 / 52 90 262
www.condor-cpc.com
skoester@condor-cpc.com

Phone:
Telefax:
Mobile:
http://
e-Mail:

+49 (0) 25 87 / 89 - 208


+49 (0) 25 87 / 89 - 44 - 208
+49 (0) 172 / 52 90 253
www.condor-cpc.com
uehlen@condor-cpc.com

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 89 - 146


+49 (0) 25 87 / 89 - 140
www.condor-cpc.com
bwinkler@condor-cpc.com

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 89 - 149


+49 (0) 25 87 / 89 - 140
www.condor-cpc.com
awiedemann@condor-cpc.com

Phone:
Telefax:
Mobile:
http://
e-Mail:

+49 (0) 25 87 / 89 - 206


+49 (0) 25 87 / 89 - 44 - 206
+49 (0) 172 / 27 87 708
www.condor-cpc.com
rpfeiffer@condor-cpc.com

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 89 - 154


+49 (0) 25 87 / 89 - 140
www.condor-cpc.com
mborrmann@condor-cpc.com

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 89 - 153


+49 (0) 25 87 / 89 - 140
www.condor-cpc.com
akasperczyk@condor-cpc.com

Sales Exports
Rudi Pfeiffer
Sales Manager Export

Monika Borrmann
Sales Administration Export
Annette Kasperczyk
Sales Administration Export

Page 7.02

www.condor-cpc.com

Head office and Subsidiaries

Holding
Condor-Werke
Gebr. Frede GmbH & Co. KG
Warendorfer Strae 47 - 51
(Ortsteil Westkirchen)
D-59320 Ennigerloh

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 89 - 0
+49 (0) 25 87 / 89 - 127
www.condor-werke.com
info@condor-werke.com

Condor Pressure Control GmbH


Warendorfer Strae 47 - 51
(Ortsteil Westkirchen)
D-59320 Ennigerloh

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 89 - 0
+49 (0) 25 87 / 89 - 140
www.condor-cpc.com
info@condor-cpc.com

Condor Systems GmbH


Warendorfer Strae 47 - 51
(Ortsteil Westkirchen)
D-59320 Ennigerloh

Phone:
Telefax:
http://
e-Mail:

+49 (0) 25 87 / 895 - 00


+49 (0) 25 87 / 895 - 99
www.condor-systemtechnik.de
info@condor-systemtechnik.de

Condor USA, Inc.


8318 Pineville-Mathews Rd.
Suite 276
Charlotte, NC 28226

Phone:
Telefax:
http://
e-Mail:

+1 704 544-8847
+1 704 756-8397
www.condor-usa.com
info@condor-usa.com

Scharco Elektronik GmbH


Tilsiter Strae 8
D-42227 Wuppertal

Phone:
Telefax:
http://
e-Mail:

+49 (0) 202 / 52 601 - 0


+49 (0) 202 / 52 601 - 30
www.scharco.de
scharco@scharco.de

Subsidiaries

www.condor-cpc.com

Page 7.03

Representatives Europe

Austria
Fabig Handelsgesellschaft mbH
Felmayergasse 4
A-1214 Wien

Phone:
Telefax:
http://
e-Mail:

+43 1 2584 606-0


+43 1 2584 606-229
www.fabig.at
aichberger@fabig.at

Phone:
Telefax:
http://
e-Mail:

+31 182 61 06 22
+31 182 61 06 19
www.condor-benelux.nl
sales@condor-benelux.nl

Phone:
Telefax:
http://
e-Mail:

+44 1942 52 58 33
+44 1942 52 34 13
www.alphacontrols.co.uk
technicalsales@alphacontrols.co.uk

Phone:
Telefax:
e-Mail:

+39 02 2871 161


+39 02 2828 636
mazzeri@mazzeri.it

Phone:
Telefax:
http://
e-Mail:

+351 22 905 90 00
+351 22 902 45 93
www.casadaslampadas.com
calamp@casadaslampadas.com

Phone:
Telefax:
http://
e-Mail:

+7 095 250 6848


+7 095 250 6805
www.et.ru
air@et.ru

Phone:
Telefax:
http://
e-Mail:

+34 932 411 566


+34 934 146 199
www.seicomsl.es
comercial@seicomsl.es

Benelux
Condor Benelux
Postbus 178
NL-2740 AD Waddinxveen
Condor Benelux
Magazijn
Coenecoop 9
NL-PG 2741 Waddinxveen

Great Britain
Alpha Controls PLC
First Floor, Unit 5
Ridgeway Estate
GB-Iver, Buckinghamsh. SLO9HX

Italy
Mazzeri S.R.L.
Via Teodosio 61-65
20131 Milano

Portugal
Casa das Lampadas, Lda.
Rua da Arroteia, 894
PT-4465-586 Lea do Balio

Russia
Econika Techno
Alleya Pervoi Mayovki 15
RU-111395 Moscow

Spain
Seicom, S. L.
(Sensors i Components Ind.)
Modolell 39
E-08021 Barcelona

Page 7.04

www.condor-cpc.com

Representatives Europe

Sweden
Solar AB
Industry Division Electrica
P. O. Box 311
S-40 125 Gothenburg

Phone:
Telefax:
http://
e-Mail:

+46 19 192 908


+46 19 192 917
www.solar.se
solar@solar.se

Rutab
Box 185
Poppelgatan 8
S-57122 Nssj

Phone:
Telefax:
http://
e-Mail:

+46 380 55 50 50
+46 380 1 23 03
www.rutab.se
info@rutab.se

Phone:
Telefax:
http://
e-Mail:

+41 44 844 06 08
+41 44 844 57 44
www.smhandelsag.ch
info@smhandelsag.ch

Phone:
Telefax:
hhtp://
e-Mail:

+90 212 210 97 50


+90 212 220 39 81
www.zetaenerji.com
nmadern@zetaenerji.com

Switzerland
SM Handels AG
Industriestr. 2
CH-8108 Dllikon

Turkey
ZETA Enerji Elk. Mak. Tic. Ltd. Sti.
Teyyarecci Resmi Sok. Arman A 9/15
TR-34744 Bostanci-Istanbul

www.condor-cpc.com

Page 7.05

Representatives Worldwide

Australia
Ross Brown Sales Pty. Ltd.
ACN 000 690 362
21 Brookhollow Ave
P.O.Box 6345 BHBC
AU-Baulkham Hills NSW 2153

Phone:
Telefax:
http://
e-Mail:

+61 2 9899 2744


+61 2 9899 4233
www.rossbrownsales.com.au
sales@rossbrownsales.com.au

Phone:
Telefax:
e-Mail:

+98 21 390 4413


+98 21 393 3616
thr_condor@dpimil.net

Phone:
Telefax:

+82 (31) 983 0688


+82 (31) 984 0365

Phone:
Telefax:
http://
e-Mail

+49 (0) 40-23 69 85-0


+49 (0) 40-23 69 85-10
www.kistenmacher.de
info@kistenmacher.de

Phone:
Telefax:

+27 (11) 8 73-34 74


+27 (11) 8 73-11 3

Phone:
Telefax:
http://
e-Mail

+1 704 544-8847
+1 704 756-8397
www.condor-usa.com
info@condor-usa.com

Iran
Tehran Condor
Sadai Allee
P.O.Box 11365-3845
Tehran

Korea
Han Young Fluid Co., Ltd.
456-17, Poongmu-Dong,
Gimpo-City
Gyounggi-Do,
456-17 Korea

Middle East / Far East


E.G. Kistenmacher GmbH & Co.
Sachsenfeld 3-5
D-20097 Hamburg (Germany)

South Africa
AC / DC Dynamics
P.O.Box 19287
ZA-Fischers Hill 1408

USA
Condor USA, Inc.
8318 Pineville-Mathews Rd.
Suite 276
Charlotte, NC 28226

Page 7.06

www.condor-cpc.com

Terms of Delivery

Terms of Delivery
During handling of order the General Terms and Conditions (AGB) of the Condor Pressure Control
GmbH are determining. These conditions can be seen under www.condor-cpc.com.
The retention of title applies also if our goods are finished or already worked on, as well as with mixture or
blending with other goods.
For demands from far sales of supplied goods the extended retention of title applies.

You find the current price list on our homepage www.condor-cpc.com as pdf-file for downloading.
Place of delivery and area of jurisdiction is Warendorf in Germany.

Impressum
Subject to design changes which serve further development without prior notice. Illustrations, dimensions
and possible typing errors are not-binding and without obligation.

www.condor-cpc.com

Page 7.07

Page 7.08

www.condor-cpc.com

Subsidiaries of Condor-Werke

Overview

Condor Systems GmbH

Page
8.02

A short introduction

Scharco Elektronik GmbH

8.03

A short introduction

Condor USA Inc.

8.04

A short introduction

www.condor-cpc.com

Page 8.01

Condor Systems GmbH

In the course of expansion of the product service


spectrum range "System Technology", Condor
Systems GmbH emerges beginning 2003 as an
independent corporate division within the Condor
group.

Consequently, Condor Systems GmbH, carries


forth the over 100 year old Condor-Werke tradition
in the field of water engineering which originally
began with the manufacturing of water pumps.

Based
on
customer
requirements
and
specifications, Condor Systems manufactures
controls mainly for the pressure and water
technology sectors (including waste water sector),
shows how a problem can be solved and
furnishes
technical
documentation
for
manufacturing the control or in advance for units
still to be planned.

Fill level measurement


Level monitoring, regulation and control
Pump controls
Rainwater harvesting
Septic tank control

Furthermore, a large part of the components


which are used in the controls are manufactured
by Condor Systems; this specially ensures safety
as well as product and delivery reliability.

In the Thirties - at which time the company was


christened Condor - due to it's intensive activity in
the field of pump technology, the company was
granted a patent which is still relevant up to the
present day for diaphragm based pressure
switches manufactured all over the world. That
laid the foundation in the field of electronic
engineering; the era of Condor switchgear had
begun.
With the manufacturing of electronic monitoring,
regulating and control units Condor Systems
carries out the next step:

Control

Regulate

Monitor

Is the motto with special focus on complete


problem solutions in the range of pressure and
water engineering, e.g.:
-

Effluent treatment
Pressure measurement, regulation and
control
Compressor monitoring and control

Page 8.02

www.condor-cpc.com

User-specific, individual and tailored, we will


gladly present you our problem solving solutions!

Scharco Elektronik GmbH

Based on long year experience in the field of


control engineering, Scharco Elektronik offers
customized solutions to almost all sectors of
industrial electronics.

water engineering, shop-fitting, gas stations and


automobile electronics.
In the scope of competent consulting, we analyse
the exact conception and requests of our clients.
In close co-operation with the client, a team of
qualified development engineers create CAE
supported diagrams, layouts, software and
designs.

Our strength lies in first-rate facilities and the


integrated logical system which offers you longterm price stability and flexibility.

This contains:
-

Project management
Production and control
Development support and technological
advice
Prototyping
Highest efficiency guarantees the production of
RoHS compliant products on state of the art SMT
and wave soldering machines.

During the entire process, from project planning to


batch delivery, all customer specific products are
subject to the high quality requirements of ISO
9001:2000. Our highly qualified engineers and
more than 40 years of experience in the different
industrial branches ensure the success of our
products in compliance with relevant standards
including those for approval obligatory or safetyrelated controls (TV, PTB, etc.).
Our major activity lies in pressure, water and
motor technology as well as controls for waste

www.condor-cpc.com

Page 8.03

Condor USA Inc.


In 1999, Condor-USA, Inc. was founded as
USsubsidiary, selling Condor products in the
North- and South American market place!
Today, Condor-USA, Inc. supplies customers in
over 15 countries with multiple product variations.

The illustration above shows a Condor pressure


switch which has been especially developed and
manufactured for the US market.

Condor USA has its own R&D department in order


to exactly match the individual products with the
customer's requirements and applications. Here,
special products and solutions are developed for
the requirements of the US market.
Before starting mass production, every product
will be thoroughly checked in own test
laboratories.

An assembly department ensures the necessary


flexibility in order to meet special requests of our
customers.
All distribution and shipment of the products for
customers all over the American continent is
handled by a central logistic center in Kentucky.

Page 8.04

www.condor-cpc.com

05.04.2007

www.condor-cpc.com

Page 8.05